{"lab":{"_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","address":"Chemická 2039/1, Mariánské Hory, 709 00 Ostrava","categories":["water","environment"],"city":"Ostrava","imported_at":"2026-03-08T10:42:44.590Z","methods_count":28,"name":"BorsodChem MCHZ, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1370_382_2025_CS.pdf","1370_382_2025_EN.pdf"],"scope_summary":"Badania w zakresie analityki wód, wyciągów wodnych i powietrza w środowisku pracy, łącznie z pobieraniem próbek","search_text":"borsodchem mchz, s.r.o. chemická 2039/1, mariánské hory, 709 00 ostrava other","status":"active","updated_at":"2026-03-08T14:52:11.396Z","valid_from":"","valid_until":"24-07-2030","website":"www.borsodchem-cz.com","parsed_at":"2026-09-28T12:00:00.000Z","location":{"type":"Point","coordinates":[18.2625,49.8209]},"map_coord":[49.834684,18.232249],"map_geo":"nominatim-street","certificate_date":"24.07.2025","certificate_no":"382/2025","certificate_replaces":"172/2023 z 11.04.2023","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania w zakresie analityki wód, wyciągów wodnych i powietrza w środowisku pracy, łącznie z pobieraniem próbek","en":"Testing in the field of analysis of water, aqueous extracts, air in working environment, including sampling","zh":"水、水浸出液及工作环境空气分析检测，包括采样","cs":"Provádění zkoušek v oboru analytika vod, vodných výluhů, ovzduší v pracovním prostředí včetně odběru vzorků"}],"flexible_scope":true,"flexible_scope_url":"https://borsodchem.cz/o-nas/politika-ims","has_en":true,"has_zh":true,"lab_division":"Laboratorium TK S-blok","lab_division_cs":"Laboratoř TK S-blok","lab_division_en":"TK S-blok Laboratory","lab_division_zh":"TK S-blok实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","scope_legend":[{"abbr":"A","pl":"procedura badawcza","en":"Test Procedure","zh":"检测程序","cs":"zkušební postup"},{"abbr":"O","pl":"procedura pobierania próbek","en":"Sampling Procedure","zh":"采样程序","cs":"postup pro odběr"},{"abbr":"GC","pl":"chromatografia gazowa","en":"Gas Chromatography","zh":"气相色谱","cs":"Gas Chromatography (plynová chromatografie)"},{"abbr":"AAS","pl":"absorpcyjna spektrometria atomowa","en":"Atomic Absorption Spectrometry","zh":"原子吸收光谱","cs":"Atomic Absorption Spectrometry - atomová absorpční spektrometrie"},{"abbr":"EPA","pl":"Agencja Ochrony Środowiska USA","en":"Environmental Protection Agency","zh":"美国环境保护署","cs":"Environmental Protection Agency"},{"abbr":"IC","pl":"chromatografia jonowa","en":"Ion Chromatography","zh":"离子色谱","cs":"Iontová chromatografie"},{"abbr":"IR","pl":"podczerwień","en":"Infrared","zh":"红外","cs":"Infrared (infračervený)"},{"abbr":"NIOSH","pl":"Narodowy Instytut Bezpieczeństwa i Higieny Pracy USA","en":"National Institute for Occupational Safety and Health","zh":"美国国家职业安全卫生研究所","cs":"National Institute for Occupational Safety and Health"},{"abbr":"SPME","pl":"mikroekstrakcja do fazy stałej","en":"Solid Phase Micro Extraction","zh":"固相微萃取","cs":"Solid Phase Micro Extraction"},{"abbr":"TD","pl":"desorpcja termiczna","en":"Thermal Desorption","zh":"热脱附","cs":"Termální desorpce"},{"abbr":"TC","pl":"węgiel całkowity","en":"Total Carbon","zh":"总碳","cs":"Total carbon (celkový uhlík)"},{"abbr":"TOC","pl":"ogólny węgiel organiczny","en":"Total Organic Carbon","zh":"总有机碳","cs":"Total organic carbon (celkový organický uhlík)"},{"abbr":"InC","pl":"węgiel nieorganiczny","en":"Inorganic Carbon","zh":"无机碳","cs":"Inorganic carbon (anorganický uhlík)"},{"abbr":"DOC","pl":"rozpuszczony węgiel organiczny","en":"Dissolved Organic Carbon","zh":"溶解性有机碳","cs":"Dissolved organic carbon (rozpuštěný organický uhlík)"},{"abbr":"TN","pl":"azot ogólny","en":"Total Nitrogen","zh":"总氮","cs":"Total nitrogen (celkový dusík)"},{"abbr":"FID","pl":"detektor płomieniowo-jonizacyjny","en":"Flame Ionisation Detector","zh":"火焰离子化检测器","cs":"Flame ionisation detector (plamenově-ionizační detektor)"},{"abbr":"ECD","pl":"detektor wychwytu elektronów","en":"Electron Capture Detector","zh":"电子捕获检测器","cs":"Electron capture detector (detektor elektronového záchytu)"},{"abbr":"NO","pl":"tlenek azotu","en":"Nitrogen oxide","zh":"一氧化氮","cs":"Oxid dusný"},{"abbr":"NO2","pl":"dwutlenek azotu","en":"Nitrogen dioxide","zh":"二氧化氮","cs":"Oxid dusičitý"},{"abbr":"NV","pl":"rozporządzenie rządu (Republiki Czeskiej)","en":"Government Regulation","zh":"政府条例","cs":"Nařízení vlády"},{"abbr":"HPLC","pl":"wysokosprawna chromatografia cieczowa","en":"High Pressure Liquid Chromatography","zh":"高效液相色谱","cs":"High Pressure Liquid Chromatography"},{"abbr":"UV VIS","pl":"spektrofotometria w zakresie nadfioletu i światła widzialnego","en":"Ultraviolet-visible spectrography","zh":"紫外-可见光谱","cs":"Ultraviolet-visible spectrography"}],"scope_notes":[{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The laboratory is qualified to carry out standalone sampling.","zh":"实验室有能力独立进行采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."}],"source_lang":"cs","source_pdf_sha256":"291f8c75873aa53b0b20c89ef51be8ace8302ae3001dcf48511127dd9d3da8be","source_pdf_url":"https://www.cai.cz/OA/pdf/382_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/382_2025_EN.pdf"},"methods":[{"_id":"7cbff3932261cceecafdc860","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"1","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie węglowodorów C10–C40","methodology_en":"Determination of hydrocarbons C10 – C40","methodology_zh":"C10–C40烃类测定","methodology_cs":"Stanovení uhlovodíků C10-C40","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda GC-FID","technique_en":"GC-FID method","technique_zh":"气相色谱-火焰离子化检测法","technique_cs":"metodou GC-FID","techniques":["Metoda GC-FID"],"techniques_en":["GC-FID method"],"techniques_zh":["气相色谱-火焰离子化检测法"],"techniques_cs":["metodou GC-FID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C10–C40\nMetoda GC-FID","reference":"A3-0200 (ČSN EN ISO 9377-2; ČSN EN 14039)","norm_bases":["A3-0200","ČSN EN ISO 9377-2","ČSN EN 14039"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie węglowodorów C10–C40 Metoda GC-FID Vody povrchové, odpadní Stanovení uhlovodíků C10-C40 metodou GC-FID A3-0200 (ČSN EN ISO 9377-2; ČSN EN 14039) Wody powierzchniowe, scieki Oznaczanie weglowodorow C10–C40 Metoda GC-FID Vody povrchove, odpadni Stanoveni uhlovodiku C10-C40 metodou GC-FID A3-0200 (CSN EN ISO 9377-2; CSN EN 14039)","search_en":"Surface water, waste water Determination of hydrocarbons C10 – C40 GC-FID method A3-0200 (ČSN EN ISO 9377-2; ČSN EN 14039)","search_zh":"地表水、废水 C10–C40烃类测定 气相色谱-火焰离子化检测法 A3-0200 (ČSN EN ISO 9377-2; ČSN EN 14039)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2fae601ba9031784f52eedbb","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"2","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie anionów","methodology_en":"Determination of anions","methodology_zh":"阴离子测定","methodology_cs":"Stanovení aniontů","parameters":[{"name":"Chlorki","range":""},{"name":"Azotany","range":""},{"name":"Azotyny","range":""},{"name":"Siarczany","range":""},{"name":"Fosforany","range":""}],"parameters_en":[{"name":"Chlorides","range":""},{"name":"Nitrates","range":""},{"name":"Nitrites","range":""},{"name":"Sulphates","range":""},{"name":"Phosphates","range":""}],"parameters_zh":[{"name":"氯化物","range":""},{"name":"硝酸盐","range":""},{"name":"亚硝酸盐","range":""},{"name":"硫酸盐","range":""},{"name":"磷酸盐","range":""}],"parameters_cs":[{"name":"chloridy","range":""},{"name":"dusičnany","range":""},{"name":"dusitany","range":""},{"name":"sírany","range":""},{"name":"fosforečnany","range":""}],"technique":"Metoda chromatografii jonowej (IC) z detekcją konduktometryczną","technique_en":"IC method with conductivity detection","technique_zh":"离子色谱法（电导检测）","technique_cs":"metodou IC s vodivostní detekcí","techniques":["Metoda chromatografii jonowej (IC) z detekcją konduktometryczną"],"techniques_en":["IC method with conductivity detection"],"techniques_zh":["离子色谱法（电导检测）"],"techniques_cs":["metodou IC s vodivostní detekcí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie anionów\nZakres:\nChlorki\nAzotany\nAzotyny\nSiarczany\nFosforany\nMetoda chromatografii jonowej (IC) z detekcją konduktometryczną","reference":"A3-0229 (ČSN EN ISO 10304-1)","norm_bases":["A3-0229","ČSN EN ISO 10304-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie anionów Metoda chromatografii jonowej (IC) z detekcją konduktometryczną Chlorki  Azotany  Azotyny  Siarczany  Fosforany  Vody povrchové, odpadní Stanovení aniontů metodou IC s vodivostní detekcí chloridy  dusičnany  dusitany  sírany  fosforečnany  A3-0229 (ČSN EN ISO 10304-1) Wody powierzchniowe, scieki Oznaczanie anionow Metoda chromatografii jonowej (IC) z detekcja konduktometryczna Chlorki  Azotany  Azotyny  Siarczany  Fosforany  Vody povrchove, odpadni Stanoveni aniontu metodou IC s vodivostni detekci chloridy  dusicnany  dusitany  sirany  fosforecnany  A3-0229 (CSN EN ISO 10304-1)","search_en":"Surface water, waste water Determination of anions IC method with conductivity detection Chlorides  Nitrates  Nitrites  Sulphates  Phosphates  A3-0229 (ČSN EN ISO 10304-1)","search_zh":"地表水、废水 阴离子测定 离子色谱法（电导检测） 氯化物  硝酸盐  亚硝酸盐  硫酸盐  磷酸盐  A3-0229 (ČSN EN ISO 10304-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dd94d707d68c3a0d8726374f","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"3","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie substancji półlotnych","methodology_en":"Determination of semi-volatile compounds","methodology_zh":"半挥发性物质测定","methodology_cs":"Stanovení semivolatilních látek","parameters":[{"name":"Anilina","range":""},{"name":"Nitrobenzen","range":""}],"parameters_en":[{"name":"Aniline","range":""},{"name":"Nitrobenzene","range":""}],"parameters_zh":[{"name":"苯胺","range":""},{"name":"硝基苯","range":""}],"parameters_cs":[{"name":"anilin","range":""},{"name":"nitrobenzen","range":""}],"technique":"Metoda SPME-GC z detekcją FID","technique_en":"SPME-GC method with FID detection","technique_zh":"固相微萃取-气相色谱法（FID检测）","technique_cs":"metodou SPME-GC s detekcí FID","techniques":["Metoda SPME-GC z detekcją FID"],"techniques_en":["SPME-GC method with FID detection"],"techniques_zh":["固相微萃取-气相色谱法（FID检测）"],"techniques_cs":["metodou SPME-GC s detekcí FID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji półlotnych\nZakres:\nAnilina\nNitrobenzen\nMetoda SPME-GC z detekcją FID","reference":"A3-0257 (EPA 8270 E)","norm_bases":["A3-0257","EPA 8270 E"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie substancji półlotnych Metoda SPME-GC z detekcją FID Anilina  Nitrobenzen  Vody povrchové, odpadní Stanovení semivolatilních látek metodou SPME-GC s detekcí FID anilin  nitrobenzen  A3-0257 (EPA 8270 E) Wody powierzchniowe, scieki Oznaczanie substancji pollotnych Metoda SPME-GC z detekcja FID Anilina  Nitrobenzen  Vody povrchove, odpadni Stanoveni semivolatilnich latek metodou SPME-GC s detekci FID anilin  nitrobenzen  A3-0257 (EPA 8270 E)","search_en":"Surface water, waste water Determination of semi-volatile compounds SPME-GC method with FID detection Aniline  Nitrobenzene  A3-0257 (EPA 8270 E)","search_zh":"地表水、废水 半挥发性物质测定 固相微萃取-气相色谱法（FID检测） 苯胺  硝基苯  A3-0257 (EPA 8270 E)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5fbbfaab9833d49d761655c0","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"4","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie fosforanów i fosforu ogólnego","methodology_en":"Determination of phosphate and total phosphorus","methodology_zh":"磷酸盐和总磷测定","methodology_cs":"Stanovení fosforečnanů a celkového fosforu","parameters":[{"name":"Fosforany","range":""},{"name":"Fosfor ogólny","range":""}],"parameters_en":[{"name":"Phosphate","range":""},{"name":"Total phosphorus","range":""}],"parameters_zh":[{"name":"磷酸盐","range":""},{"name":"总磷","range":""}],"parameters_cs":[{"name":"fosforečnany","range":""},{"name":"celkového fosforu","range":""}],"technique":"Metoda spektrofotometryczna z użyciem zestawu komercyjnego firmy HACH","technique_en":"By spectrophotometry using HACH commercial set","technique_zh":"分光光度法（HACH商业试剂盒）","technique_cs":"spektrofotometricky komerční soupravou firmy HACH","techniques":["Metoda spektrofotometryczna z użyciem zestawu komercyjnego firmy HACH"],"techniques_en":["By spectrophotometry using HACH commercial set"],"techniques_zh":["分光光度法（HACH商业试剂盒）"],"techniques_cs":["spektrofotometricky komerční soupravou firmy HACH"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforanów i fosforu ogólnego\nZakres:\nFosforany\nFosfor ogólny\nMetoda spektrofotometryczna z użyciem zestawu komercyjnego firmy HACH","reference":"A3-0315 (ČSN ISO 17381; návod firmy HACH)","norm_bases":["A3-0315","ČSN ISO 17381","návod firmy HACH"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie fosforanów i fosforu ogólnego Metoda spektrofotometryczna z użyciem zestawu komercyjnego firmy HACH Fosforany  Fosfor ogólny  Vody povrchové, odpadní Stanovení fosforečnanů a celkového fosforu spektrofotometricky komerční soupravou firmy HACH fosforečnany  celkového fosforu  A3-0315 (ČSN ISO 17381; návod firmy HACH) Wody powierzchniowe, scieki Oznaczanie fosforanow i fosforu ogolnego Metoda spektrofotometryczna z uzyciem zestawu komercyjnego firmy HACH Fosforany  Fosfor ogolny  Vody povrchove, odpadni Stanoveni fosforecnanu a celkoveho fosforu spektrofotometricky komercni soupravou firmy HACH fosforecnany  celkoveho fosforu  A3-0315 (CSN ISO 17381; navod firmy HACH)","search_en":"Surface water, waste water Determination of phosphate and total phosphorus By spectrophotometry using HACH commercial set Phosphate  Total phosphorus  A3-0315 (ČSN ISO 17381; návod firmy HACH)","search_zh":"地表水、废水 磷酸盐和总磷测定 分光光度法（HACH商业试剂盒） 磷酸盐  总磷  A3-0315 (ČSN ISO 17381; návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"340bcbdb35b73e4f1418dbbd","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"5","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie metali","methodology_en":"Determination of metals","methodology_zh":"金属测定","methodology_cs":"Stanovení kovů","parameters":[{"name":"Żelazo (Fe)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Sód (Na)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""}],"parameters_en":[{"name":"Iron (Fe)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""}],"parameters_zh":[{"name":"铁（Fe）","range":""},{"name":"铜（Cu）","range":""},{"name":"镍（Ni）","range":""},{"name":"铬（Cr）","range":""},{"name":"锌（Zn）","range":""},{"name":"镉（Cd）","range":""},{"name":"铅（Pb）","range":""},{"name":"钙（Ca）","range":""},{"name":"钠（Na）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""}],"parameters_cs":[{"name":"Fe","range":""},{"name":"Cu","range":""},{"name":"Ni","range":""},{"name":"Cr","range":""},{"name":"Zn","range":""},{"name":"Cd","range":""},{"name":"Pb","range":""},{"name":"Ca","range":""},{"name":"Na","range":""},{"name":"K","range":""},{"name":"Mg","range":""}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (AAS-płomień)","technique_en":"Flame AAS method","technique_zh":"火焰原子吸收光谱法","technique_cs":"metodou AAS-plamen","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (AAS-płomień)"],"techniques_en":["Flame AAS method"],"techniques_zh":["火焰原子吸收光谱法"],"techniques_cs":["metodou AAS-plamen"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali\nZakres:\nŻelazo (Fe)\nMiedź (Cu)\nNikiel (Ni)\nChrom (Cr)\nCynk (Zn)\nKadm (Cd)\nOłów (Pb)\nWapń (Ca)\nSód (Na)\nPotas (K)\nMagnez (Mg)\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (AAS-płomień)","reference":"A3-0345 (ČSN ISO 8288; ČSN EN 1233; ČSN ISO 7980; ČSN 75 7385; ČSN ISO 9964-2; ČSN ISO 9964-1)","norm_bases":["A3-0345","ČSN ISO 8288","ČSN EN 1233","ČSN ISO 7980","ČSN 75 7385","ČSN ISO 9964-2","ČSN ISO 9964-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie metali Metoda płomieniowej absorpcyjnej spektrometrii atomowej (AAS-płomień) Żelazo (Fe)  Miedź (Cu)  Nikiel (Ni)  Chrom (Cr)  Cynk (Zn)  Kadm (Cd)  Ołów (Pb)  Wapń (Ca)  Sód (Na)  Potas (K)  Magnez (Mg)  Vody povrchové, odpadní Stanovení kovů metodou AAS-plamen Fe  Cu  Ni  Cr  Zn  Cd  Pb  Ca  Na  K  Mg  A3-0345 (ČSN ISO 8288; ČSN EN 1233; ČSN ISO 7980; ČSN 75 7385; ČSN ISO 9964-2; ČSN ISO 9964-1) Wody powierzchniowe, scieki Oznaczanie metali Metoda plomieniowej absorpcyjnej spektrometrii atomowej (AAS-plomien) Zelazo (Fe)  Miedz (Cu)  Nikiel (Ni)  Chrom (Cr)  Cynk (Zn)  Kadm (Cd)  Olow (Pb)  Wapn (Ca)  Sod (Na)  Potas (K)  Magnez (Mg)  Vody povrchove, odpadni Stanoveni kovu metodou AAS-plamen Fe  Cu  Ni  Cr  Zn  Cd  Pb  Ca  Na  K  Mg  A3-0345 (CSN ISO 8288; CSN EN 1233; CSN ISO 7980; CSN 75 7385; CSN ISO 9964-2; CSN ISO 9964-1)","search_en":"Surface water, waste water Determination of metals Flame AAS method Iron (Fe)  Copper (Cu)  Nickel (Ni)  Chromium (Cr)  Zinc (Zn)  Cadmium (Cd)  Lead (Pb)  Calcium (Ca)  Sodium (Na)  Potassium (K)  Magnesium (Mg)  A3-0345 (ČSN ISO 8288; ČSN EN 1233; ČSN ISO 7980; ČSN 75 7385; ČSN ISO 9964-2; ČSN ISO 9964-1)","search_zh":"地表水、废水 金属测定 火焰原子吸收光谱法 铁（Fe）  铜（Cu）  镍（Ni）  铬（Cr）  锌（Zn）  镉（Cd）  铅（Pb）  钙（Ca）  钠（Na）  钾（K）  镁（Mg）  A3-0345 (ČSN ISO 8288; ČSN EN 1233; ČSN ISO 7980; ČSN 75 7385; ČSN ISO 9964-2; ČSN ISO 9964-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9f533a5402018f602b987629","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"6","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie jonów amonowych","methodology_en":"Determination of ammonium","methodology_zh":"铵离子测定","methodology_cs":"Stanovení amonných iontů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"By spectrophotometry","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["By spectrophotometry"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych\nMetoda spektrofotometryczna","reference":"A3-0368 (ČSN ISO 7150-1)","norm_bases":["A3-0368","ČSN ISO 7150-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie jonów amonowych Metoda spektrofotometryczna Vody povrchové, odpadní Stanovení amonných iontů spektrofotometricky A3-0368 (ČSN ISO 7150-1) Wody powierzchniowe, scieki Oznaczanie jonow amonowych Metoda spektrofotometryczna Vody povrchove, odpadni Stanoveni amonnych iontu spektrofotometricky A3-0368 (CSN ISO 7150-1)","search_en":"Surface water, waste water Determination of ammonium By spectrophotometry A3-0368 (ČSN ISO 7150-1)","search_zh":"地表水、废水 铵离子测定 分光光度法 A3-0368 (ČSN ISO 7150-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2091dcdee546bcde904fd590","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"7","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie fenoli","methodology_en":"Determination of phenols","methodology_zh":"酚类测定","methodology_cs":"Stanovení fenolů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"By spectrophotometry","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["By spectrophotometry"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fenoli\nMetoda spektrofotometryczna","reference":"A3-0369 (ČSN ISO 6439)","norm_bases":["A3-0369","ČSN ISO 6439"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie fenoli Metoda spektrofotometryczna Vody povrchové, odpadní Stanovení fenolů spektrofotometricky A3-0369 (ČSN ISO 6439) Wody powierzchniowe, scieki Oznaczanie fenoli Metoda spektrofotometryczna Vody povrchove, odpadni Stanoveni fenolu spektrofotometricky A3-0369 (CSN ISO 6439)","search_en":"Surface water, waste water Determination of phenols By spectrophotometry A3-0369 (ČSN ISO 6439)","search_zh":"地表水、废水 酚类测定 分光光度法 A3-0369 (ČSN ISO 6439)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"811a377f692ade978be89006","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"8","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie azotanów","methodology_en":"Determination of nitrate","methodology_zh":"硝酸盐测定","methodology_cs":"Stanovení dusičnanů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"By spectrophotometry","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["By spectrophotometry"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":["Azot azotanowy (z obliczeń)"],"computed_en":["Nitrate nitrogen (calculated)"],"computed_zh":["硝酸盐氮（计算）"],"computed_cs":["dusičnanového dusíku dopočtem"],"activity":"Oznaczanie azotanów\nMetoda spektrofotometryczna","reference":"A3-0370 (ČSN ISO 7890-3)","norm_bases":["A3-0370","ČSN ISO 7890-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie azotanów Metoda spektrofotometryczna Azot azotanowy (z obliczeń) Vody povrchové, odpadní Stanovení dusičnanů spektrofotometricky dusičnanového dusíku dopočtem A3-0370 (ČSN ISO 7890-3) Wody powierzchniowe, scieki Oznaczanie azotanow Metoda spektrofotometryczna Azot azotanowy (z obliczen) Vody povrchove, odpadni Stanoveni dusicnanu spektrofotometricky dusicnanoveho dusiku dopoctem A3-0370 (CSN ISO 7890-3)","search_en":"Surface water, waste water Determination of nitrate By spectrophotometry Nitrate nitrogen (calculated) A3-0370 (ČSN ISO 7890-3)","search_zh":"地表水、废水 硝酸盐测定 分光光度法 硝酸盐氮（计算） A3-0370 (ČSN ISO 7890-3)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f26c5486d534f19da7a81eed","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"9","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu (ChZT-Cr)","methodology_en":"Determination of chemical oxygen demand (CODCr)","methodology_zh":"化学需氧量（COD-Cr）测定","methodology_cs":"Stanovení chemické spotřeby kyslíku (CHSKCr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna z użyciem zestawu komercyjnego firmy HACH","technique_en":"By spectrophotometry using HACH commercial set","technique_zh":"分光光度法（HACH商业试剂盒）","technique_cs":"spektrofotometricky komerční soupravou firmy HACH","techniques":["Metoda spektrofotometryczna z użyciem zestawu komercyjnego firmy HACH"],"techniques_en":["By spectrophotometry using HACH commercial set"],"techniques_zh":["分光光度法（HACH商业试剂盒）"],"techniques_cs":["spektrofotometricky komerční soupravou firmy HACH"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu (ChZT-Cr)\nMetoda spektrofotometryczna z użyciem zestawu komercyjnego firmy HACH","reference":"A3-0373 (ČSN ISO 17381; návod firmy HACH)","norm_bases":["A3-0373","ČSN ISO 17381","návod firmy HACH"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie chemicznego zapotrzebowania tlenu (ChZT-Cr) Metoda spektrofotometryczna z użyciem zestawu komercyjnego firmy HACH Vody povrchové, odpadní Stanovení chemické spotřeby kyslíku (CHSKCr) spektrofotometricky komerční soupravou firmy HACH A3-0373 (ČSN ISO 17381; návod firmy HACH) Wody powierzchniowe, scieki Oznaczanie chemicznego zapotrzebowania tlenu (ChZT-Cr) Metoda spektrofotometryczna z uzyciem zestawu komercyjnego firmy HACH Vody povrchove, odpadni Stanoveni chemicke spotreby kysliku (CHSKCr) spektrofotometricky komercni soupravou firmy HACH A3-0373 (CSN ISO 17381; navod firmy HACH)","search_en":"Surface water, waste water Determination of chemical oxygen demand (CODCr) By spectrophotometry using HACH commercial set A3-0373 (ČSN ISO 17381; návod firmy HACH)","search_zh":"地表水、废水 化学需氧量（COD-Cr）测定 分光光度法（HACH商业试剂盒） A3-0373 (ČSN ISO 17381; návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"08a8d0481761a5557e338296","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"10","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie azotynów","methodology_en":"Determination of nitrite","methodology_zh":"亚硝酸盐测定","methodology_cs":"Stanovení dusitanů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"By spectrophotometry","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["By spectrophotometry"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":["Azot azotynowy (z obliczeń)"],"computed_en":["Nitrite nitrogen (calculated)"],"computed_zh":["亚硝酸盐氮（计算）"],"computed_cs":["dusitanového dusíku dopočtem"],"activity":"Oznaczanie azotynów\nMetoda spektrofotometryczna","reference":"A3-0391 (ČSN EN 26777)","norm_bases":["A3-0391","ČSN EN 26777"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie azotynów Metoda spektrofotometryczna Azot azotynowy (z obliczeń) Vody povrchové, odpadní Stanovení dusitanů spektrofotometricky dusitanového dusíku dopočtem A3-0391 (ČSN EN 26777) Wody powierzchniowe, scieki Oznaczanie azotynow Metoda spektrofotometryczna Azot azotynowy (z obliczen) Vody povrchove, odpadni Stanoveni dusitanu spektrofotometricky dusitanoveho dusiku dopoctem A3-0391 (CSN EN 26777)","search_en":"Surface water, waste water Determination of nitrite By spectrophotometry Nitrite nitrogen (calculated) A3-0391 (ČSN EN 26777)","search_zh":"地表水、废水 亚硝酸盐测定 分光光度法 亚硝酸盐氮（计算） A3-0391 (ČSN EN 26777)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ec3be78104193e04437ad8f0","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"11","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie ozonu","methodology_en":"Determination of ozone","methodology_zh":"臭氧测定","methodology_cs":"Stanovení ozónu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"By spectrophotometry","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["By spectrophotometry"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ozonu\nMetoda spektrofotometryczna","reference":"A3-0395 (návod firmy EUTECH)","norm_bases":["A3-0395","návod firmy EUTECH"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie ozonu Metoda spektrofotometryczna Vody povrchové, odpadní Stanovení ozónu spektrofotometricky A3-0395 (návod firmy EUTECH) Wody powierzchniowe, scieki Oznaczanie ozonu Metoda spektrofotometryczna Vody povrchove, odpadni Stanoveni ozonu spektrofotometricky A3-0395 (navod firmy EUTECH)","search_en":"Surface water, waste water Determination of ozone By spectrophotometry A3-0395 (návod firmy EUTECH)","search_zh":"地表水、废水 臭氧测定 分光光度法 A3-0395 (návod firmy EUTECH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c880d83ff1e42bda224d7e5c","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"12","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie substancji rozpuszczonych i rozpuszczonych soli nieorganicznych","methodology_en":"Determination of dissolved solids and dissolved inorganic salts","methodology_zh":"溶解性物质和溶解性无机盐测定","methodology_cs":"Stanovení rozpuštěných látek a rozpuštěných anorganických solí","parameters":[{"name":"Substancje rozpuszczone","range":""},{"name":"Rozpuszczone sole nieorganiczne","range":""}],"parameters_en":[{"name":"Dissolved solids","range":""},{"name":"Dissolved inorganic salts","range":""}],"parameters_zh":[{"name":"溶解性物质","range":""},{"name":"溶解性无机盐","range":""}],"parameters_cs":[{"name":"rozpuštěných látek","range":""},{"name":"rozpuštěných anorganických solí","range":""}],"technique":"Metoda wagowa","technique_en":"By gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["Metoda wagowa"],"techniques_en":["By gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych i rozpuszczonych soli nieorganicznych\nZakres:\nSubstancje rozpuszczone\nRozpuszczone sole nieorganiczne\nMetoda wagowa","reference":"A3-0431A (ČSN 75 7346; ČSN 75 7347)","norm_bases":["A3-0431A","ČSN 75 7346","ČSN 75 7347"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie substancji rozpuszczonych i rozpuszczonych soli nieorganicznych Metoda wagowa Substancje rozpuszczone  Rozpuszczone sole nieorganiczne  Vody povrchové, odpadní Stanovení rozpuštěných látek a rozpuštěných anorganických solí gravimetricky rozpuštěných látek  rozpuštěných anorganických solí  A3-0431A (ČSN 75 7346; ČSN 75 7347) Wody powierzchniowe, scieki Oznaczanie substancji rozpuszczonych i rozpuszczonych soli nieorganicznych Metoda wagowa Substancje rozpuszczone  Rozpuszczone sole nieorganiczne  Vody povrchove, odpadni Stanoveni rozpustenych latek a rozpustenych anorganickych soli gravimetricky rozpustenych latek  rozpustenych anorganickych soli  A3-0431A (CSN 75 7346; CSN 75 7347)","search_en":"Surface water, waste water Determination of dissolved solids and dissolved inorganic salts By gravimetry Dissolved solids  Dissolved inorganic salts  A3-0431A (ČSN 75 7346; ČSN 75 7347)","search_zh":"地表水、废水 溶解性物质和溶解性无机盐测定 重量法 溶解性物质  溶解性无机盐  A3-0431A (ČSN 75 7346; ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0e79ea1e26f16d1c4e252a8b","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"13","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5)","methodology_en":"Determination of biochemical oxygen demand (BOD5)","methodology_zh":"五日生化需氧量（BOD5）测定","methodology_cs":"Stanovení biochemické spotřeby kyslíku (BSK5)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda manometryczna","technique_en":"By manometric method","technique_zh":"压力计法","technique_cs":"manometricky","techniques":["Metoda manometryczna"],"techniques_en":["By manometric method"],"techniques_zh":["压力计法"],"techniques_cs":["manometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5)\nMetoda manometryczna","reference":"A3-0592 (návod firmy WTW)","norm_bases":["A3-0592","návod firmy WTW"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) Metoda manometryczna Vody povrchové, odpadní Stanovení biochemické spotřeby kyslíku (BSK5) manometricky A3-0592 (návod firmy WTW) Wody powierzchniowe, scieki Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) Metoda manometryczna Vody povrchove, odpadni Stanoveni biochemicke spotreby kysliku (BSK5) manometricky A3-0592 (navod firmy WTW)","search_en":"Surface water, waste water Determination of biochemical oxygen demand (BOD5) By manometric method A3-0592 (návod firmy WTW)","search_zh":"地表水、废水 五日生化需氧量（BOD5）测定 压力计法 A3-0592 (návod firmy WTW)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6b0accff2b311a827e128a52","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"14","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie przewodności elektrycznej właściwej","methodology_en":"Determination of electrical conductivity","methodology_zh":"电导率测定","methodology_cs":"Stanovení elektrické konduktivity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej właściwej","reference":"A3-0829 (ČSN EN 27888)","norm_bases":["A3-0829","ČSN EN 27888"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie przewodności elektrycznej właściwej Vody povrchové, odpadní Stanovení elektrické konduktivity A3-0829 (ČSN EN 27888) Wody powierzchniowe, scieki Oznaczanie przewodnosci elektrycznej wlasciwej Vody povrchove, odpadni Stanoveni elektricke konduktivity A3-0829 (CSN EN 27888)","search_en":"Surface water, waste water Determination of electrical conductivity A3-0829 (ČSN EN 27888)","search_zh":"地表水、废水 电导率测定 A3-0829 (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a469b2251eb5e923d804f1e2","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"15","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie TC, TOC, InC, DOC","methodology_en":"Determination of TC, TOC, InC, DOC","methodology_zh":"TC、TOC、InC、DOC测定","methodology_cs":"Stanovení TC, TOC, InC, DOC","parameters":[{"name":"Węgiel całkowity (TC)","range":""},{"name":"Ogólny węgiel organiczny (TOC)","range":""},{"name":"Węgiel nieorganiczny (InC)","range":""},{"name":"Rozpuszczony węgiel organiczny (DOC)","range":""}],"parameters_en":[{"name":"Total carbon (TC)","range":""},{"name":"Total organic carbon (TOC)","range":""},{"name":"Inorganic carbon (InC)","range":""},{"name":"Dissolved organic carbon (DOC)","range":""}],"parameters_zh":[{"name":"总碳（TC）","range":""},{"name":"总有机碳（TOC）","range":""},{"name":"无机碳（InC）","range":""},{"name":"溶解性有机碳（DOC）","range":""}],"parameters_cs":[{"name":"TC","range":""},{"name":"TOC","range":""},{"name":"InC","range":""},{"name":"DOC","range":""}],"technique":"Analizator z detekcją w podczerwieni (IR)","technique_en":"Analyzer with IR detection","technique_zh":"红外检测分析仪","technique_cs":"analyzátorem s IR detekcí","techniques":["Analizator z detekcją w podczerwieni (IR)"],"techniques_en":["Analyzer with IR detection"],"techniques_zh":["红外检测分析仪"],"techniques_cs":["analyzátorem s IR detekcí"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie TC, TOC, InC, DOC\nZakres:\nWęgiel całkowity (TC)\nOgólny węgiel organiczny (TOC)\nWęgiel nieorganiczny (InC)\nRozpuszczony węgiel organiczny (DOC)\nAnalizator z detekcją w podczerwieni (IR)","reference":"A3-0922A (ČSN EN ISO 20236)","norm_bases":["A3-0922A","ČSN EN ISO 20236"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie TC, TOC, InC, DOC Analizator z detekcją w podczerwieni (IR) Węgiel całkowity (TC)  Ogólny węgiel organiczny (TOC)  Węgiel nieorganiczny (InC)  Rozpuszczony węgiel organiczny (DOC)  Vody povrchové, odpadní Stanovení TC, TOC, InC, DOC analyzátorem s IR detekcí TC  TOC  InC  DOC  A3-0922A (ČSN EN ISO 20236) Wody powierzchniowe, scieki Oznaczanie TC, TOC, InC, DOC Analizator z detekcja w podczerwieni (IR) Wegiel calkowity (TC)  Ogolny wegiel organiczny (TOC)  Wegiel nieorganiczny (InC)  Rozpuszczony wegiel organiczny (DOC)  Vody povrchove, odpadni Stanoveni TC, TOC, InC, DOC analyzatorem s IR detekci TC  TOC  InC  DOC  A3-0922A (CSN EN ISO 20236)","search_en":"Surface water, waste water Determination of TC, TOC, InC, DOC Analyzer with IR detection Total carbon (TC)  Total organic carbon (TOC)  Inorganic carbon (InC)  Dissolved organic carbon (DOC)  A3-0922A (ČSN EN ISO 20236)","search_zh":"地表水、废水 TC、TOC、InC、DOC测定 红外检测分析仪 总碳（TC）  总有机碳（TOC）  无机碳（InC）  溶解性有机碳（DOC）  A3-0922A (ČSN EN ISO 20236)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d1486f872f50759ec9815887","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"16","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie pH","methodology_en":"Determination of pH","methodology_zh":"pH值测定","methodology_cs":"Stanovení pH","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda potencjometryczna","technique_en":"By potentiometry","technique_zh":"电位法","technique_cs":"potenciometricky","techniques":["Metoda potencjometryczna"],"techniques_en":["By potentiometry"],"techniques_zh":["电位法"],"techniques_cs":["potenciometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH\nMetoda potencjometryczna","reference":"A3-1023 (ČSN ISO 10523)","norm_bases":["A3-1023","ČSN ISO 10523"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie pH Metoda potencjometryczna Vody povrchové, odpadní Stanovení pH potenciometricky A3-1023 (ČSN ISO 10523) Wody powierzchniowe, scieki Oznaczanie pH Metoda potencjometryczna Vody povrchove, odpadni Stanoveni pH potenciometricky A3-1023 (CSN ISO 10523)","search_en":"Surface water, waste water Determination of pH By potentiometry A3-1023 (ČSN ISO 10523)","search_zh":"地表水、废水 pH值测定 电位法 A3-1023 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"991d0ba6986cc3159a967c34","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"17","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie substancji lotnych","methodology_en":"Determination of volatile compounds","methodology_zh":"挥发性物质测定","methodology_cs":"Stanovení volatilních látek","parameters":[{"name":"Benzen","range":""},{"name":"Toluen","range":""},{"name":"Ksyleny","range":""}],"parameters_en":[{"name":"Benzene","range":""},{"name":"Toluene","range":""},{"name":"Xylenes","range":""}],"parameters_zh":[{"name":"苯","range":""},{"name":"甲苯","range":""},{"name":"二甲苯","range":""}],"parameters_cs":[{"name":"benzen","range":""},{"name":"toluen","range":""},{"name":"xyleny","range":""}],"technique":"Metoda SPME-GC z detekcją FID","technique_en":"SPME-GC method with FID detection","technique_zh":"固相微萃取-气相色谱法（FID检测）","technique_cs":"metodou SPME-GC s detekcí FID","techniques":["Metoda SPME-GC z detekcją FID"],"techniques_en":["SPME-GC method with FID detection"],"techniques_zh":["固相微萃取-气相色谱法（FID检测）"],"techniques_cs":["metodou SPME-GC s detekcí FID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji lotnych\nZakres:\nBenzen\nToluen\nKsyleny\nMetoda SPME-GC z detekcją FID","reference":"A3-2047 (ČSN EN ISO 15680; ČSN ISO 11423-2)","norm_bases":["A3-2047","ČSN EN ISO 15680","ČSN ISO 11423-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie substancji lotnych Metoda SPME-GC z detekcją FID Benzen  Toluen  Ksyleny  Vody povrchové, odpadní Stanovení volatilních látek metodou SPME-GC s detekcí FID benzen  toluen  xyleny  A3-2047 (ČSN EN ISO 15680; ČSN ISO 11423-2) Wody powierzchniowe, scieki Oznaczanie substancji lotnych Metoda SPME-GC z detekcja FID Benzen  Toluen  Ksyleny  Vody povrchove, odpadni Stanoveni volatilnich latek metodou SPME-GC s detekci FID benzen  toluen  xyleny  A3-2047 (CSN EN ISO 15680; CSN ISO 11423-2)","search_en":"Surface water, waste water Determination of volatile compounds SPME-GC method with FID detection Benzene  Toluene  Xylenes  A3-2047 (ČSN EN ISO 15680; ČSN ISO 11423-2)","search_zh":"地表水、废水 挥发性物质测定 固相微萃取-气相色谱法（FID检测） 苯  甲苯  二甲苯  A3-2047 (ČSN EN ISO 15680; ČSN ISO 11423-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cd116ad7fbcfde772606cb01","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"18","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Workplace atmospheres","test_object_zh":"工作场所空气","test_object_cs":"Ovzduší pracovní","methodology":"Oznaczanie substancji organicznych","methodology_en":"Determination of organic compounds","methodology_zh":"有机物测定","methodology_cs":"Stanovení organických látek","parameters":[{"name":"Benzen","range":""},{"name":"Aceton","range":""},{"name":"Anilina","range":""},{"name":"N-etyloanilina","range":""},{"name":"N,N-dietyloanilina","range":""},{"name":"Nitrobenzen","range":""},{"name":"Dimetyloamina","range":""},{"name":"Dimetyloizopropyloamina","range":""},{"name":"Cykloheksyloamina","range":""},{"name":"Dimetylocykloheksyloamina","range":""},{"name":"Glikol dietylenowy","range":""}],"parameters_en":[{"name":"Benzene","range":""},{"name":"Acetone","range":""},{"name":"Aniline","range":""},{"name":"N-ethylaniline","range":""},{"name":"N,N-diethylaniline","range":""},{"name":"Nitrobenzene","range":""},{"name":"Dimethylamine","range":""},{"name":"Dimethylisopropylamine","range":""},{"name":"Cyclohexylamine","range":""},{"name":"Dimethylcyclohexylamine","range":""},{"name":"Diethylene glycol","range":""}],"parameters_zh":[{"name":"苯","range":""},{"name":"丙酮","range":""},{"name":"苯胺","range":""},{"name":"N-乙基苯胺","range":""},{"name":"N,N-二乙基苯胺","range":""},{"name":"硝基苯","range":""},{"name":"二甲胺","range":""},{"name":"二甲基异丙胺","range":""},{"name":"环己胺","range":""},{"name":"二甲基环己胺","range":""},{"name":"二乙二醇","range":""}],"parameters_cs":[{"name":"benzen","range":""},{"name":"aceton","range":""},{"name":"anilin","range":""},{"name":"N-ethylanilin","range":""},{"name":"N,N-diethylanilin","range":""},{"name":"nitrobenzen","range":""},{"name":"dimethylamin","range":""},{"name":"dimethylisopropylamin","range":""},{"name":"cyklohexylamin","range":""},{"name":"dimethylcyklohexylamin","range":""},{"name":"diethylenglykol","range":""}],"technique":"Metoda TD-GC (desorpcja termiczna) z detekcją FID","technique_en":"TD-GC method with FID detection","technique_zh":"热脱附-气相色谱法（FID检测）","technique_cs":"metodou TD-GC s detekcí FID","techniques":["Metoda TD-GC (desorpcja termiczna) z detekcją FID"],"techniques_en":["TD-GC method with FID detection"],"techniques_zh":["热脱附-气相色谱法（FID检测）"],"techniques_cs":["metodou TD-GC s detekcí FID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji organicznych\nZakres:\nBenzen\nAceton\nAnilina\nN-etyloanilina\nN,N-dietyloanilina\nNitrobenzen\nDimetyloamina\nDimetyloizopropyloamina\nCykloheksyloamina\nDimetylocykloheksyloamina\nGlikol dietylenowy\nMetoda TD-GC (desorpcja termiczna) z detekcją FID","reference":"A3-0254 (ČSN EN ISO 16017-1; EPA TO-17)","norm_bases":["A3-0254","ČSN EN ISO 16017-1","EPA TO-17"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Oznaczanie substancji organicznych Metoda TD-GC (desorpcja termiczna) z detekcją FID Benzen  Aceton  Anilina  N-etyloanilina  N,N-dietyloanilina  Nitrobenzen  Dimetyloamina  Dimetyloizopropyloamina  Cykloheksyloamina  Dimetylocykloheksyloamina  Glikol dietylenowy  Ovzduší pracovní Stanovení organických látek metodou TD-GC s detekcí FID benzen  aceton  anilin  N-ethylanilin  N,N-diethylanilin  nitrobenzen  dimethylamin  dimethylisopropylamin  cyklohexylamin  dimethylcyklohexylamin  diethylenglykol  A3-0254 (ČSN EN ISO 16017-1; EPA TO-17) Powietrze na stanowiskach pracy Oznaczanie substancji organicznych Metoda TD-GC (desorpcja termiczna) z detekcja FID Benzen  Aceton  Anilina  N-etyloanilina  N,N-dietyloanilina  Nitrobenzen  Dimetyloamina  Dimetyloizopropyloamina  Cykloheksyloamina  Dimetylocykloheksyloamina  Glikol dietylenowy  Ovzdusi pracovni Stanoveni organickych latek metodou TD-GC s detekci FID benzen  aceton  anilin  N-ethylanilin  N,N-diethylanilin  nitrobenzen  dimethylamin  dimethylisopropylamin  cyklohexylamin  dimethylcyklohexylamin  diethylenglykol  A3-0254 (CSN EN ISO 16017-1; EPA TO-17)","search_en":"Workplace atmospheres Determination of organic compounds TD-GC method with FID detection Benzene  Acetone  Aniline  N-ethylaniline  N,N-diethylaniline  Nitrobenzene  Dimethylamine  Dimethylisopropylamine  Cyclohexylamine  Dimethylcyclohexylamine  Diethylene glycol  A3-0254 (ČSN EN ISO 16017-1; EPA TO-17)","search_zh":"工作场所空气 有机物测定 热脱附-气相色谱法（FID检测） 苯  丙酮  苯胺  N-乙基苯胺  N,N-二乙基苯胺  硝基苯  二甲胺  二甲基异丙胺  环己胺  二甲基环己胺  二乙二醇  A3-0254 (ČSN EN ISO 16017-1; EPA TO-17)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"60731951ab3c9d2f02a12614","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"19","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Workplace atmospheres","test_object_zh":"工作场所空气","test_object_cs":"Ovzduší pracovní","methodology":"Oznaczanie NO, NO2, NH3","methodology_en":"Determination of NO, NO2, NH3","methodology_zh":"NO、NO2、NH3测定","methodology_cs":"Stanovení NO, NO2, NH3","parameters":[{"name":"Tlenek azotu (NO)","range":""},{"name":"Dwutlenek azotu (NO2)","range":""},{"name":"Amoniak (NH3)","range":""}],"parameters_en":[{"name":"Nitric oxide (NO)","range":""},{"name":"Nitrogen dioxide (NO2)","range":""},{"name":"Ammonia (NH3)","range":""}],"parameters_zh":[{"name":"一氧化氮（NO）","range":""},{"name":"二氧化氮（NO2）","range":""},{"name":"氨（NH3）","range":""}],"parameters_cs":[{"name":"NO","range":""},{"name":"NO2","range":""},{"name":"NH3","range":""}],"technique":"Analizator elektrochemiczny","technique_en":"Electrochemical analyzer","technique_zh":"电化学分析仪","technique_cs":"elektrochemickým analyzátorem","techniques":["Analizator elektrochemiczny"],"techniques_en":["Electrochemical analyzer"],"techniques_zh":["电化学分析仪"],"techniques_cs":["elektrochemickým analyzátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie NO, NO2, NH3\nZakres:\nTlenek azotu (NO)\nDwutlenek azotu (NO2)\nAmoniak (NH3)\nAnalizator elektrochemiczny","reference":"A3-0310 (návod firmy IBRID)","norm_bases":["A3-0310","návod firmy IBRID"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Oznaczanie NO, NO2, NH3 Analizator elektrochemiczny Tlenek azotu (NO)  Dwutlenek azotu (NO2)  Amoniak (NH3)  Ovzduší pracovní Stanovení NO, NO2, NH3 elektrochemickým analyzátorem NO  NO2  NH3  A3-0310 (návod firmy IBRID) Powietrze na stanowiskach pracy Oznaczanie NO, NO2, NH3 Analizator elektrochemiczny Tlenek azotu (NO)  Dwutlenek azotu (NO2)  Amoniak (NH3)  Ovzdusi pracovni Stanoveni NO, NO2, NH3 elektrochemickym analyzatorem NO  NO2  NH3  A3-0310 (navod firmy IBRID)","search_en":"Workplace atmospheres Determination of NO, NO2, NH3 Electrochemical analyzer Nitric oxide (NO)  Nitrogen dioxide (NO2)  Ammonia (NH3)  A3-0310 (návod firmy IBRID)","search_zh":"工作场所空气 NO、NO2、NH3测定 电化学分析仪 一氧化氮（NO）  二氧化氮（NO2）  氨（NH3）  A3-0310 (návod firmy IBRID)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"61d82ee40fb664511ebbc5cc","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"20","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Workplace atmospheres","test_object_zh":"工作场所空气","test_object_cs":"Ovzduší pracovní","methodology":"Oznaczanie amoniaku","methodology_en":"Determination of ammonia","methodology_zh":"氨测定","methodology_cs":"Stanovení amoniaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"By spectrophotometry","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["By spectrophotometry"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie amoniaku\nMetoda spektrofotometryczna","reference":"A3-0339 (ČSN 83 4728-4; NIOSH 6015; ČSN ISO 7150-1)","norm_bases":["A3-0339","ČSN 83 4728-4","NIOSH 6015","ČSN ISO 7150-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Oznaczanie amoniaku Metoda spektrofotometryczna Ovzduší pracovní Stanovení amoniaku spektrofotometricky A3-0339 (ČSN 83 4728-4; NIOSH 6015; ČSN ISO 7150-1) Powietrze na stanowiskach pracy Oznaczanie amoniaku Metoda spektrofotometryczna Ovzdusi pracovni Stanoveni amoniaku spektrofotometricky A3-0339 (CSN 83 4728-4; NIOSH 6015; CSN ISO 7150-1)","search_en":"Workplace atmospheres Determination of ammonia By spectrophotometry A3-0339 (ČSN 83 4728-4; NIOSH 6015; ČSN ISO 7150-1)","search_zh":"工作场所空气 氨测定 分光光度法 A3-0339 (ČSN 83 4728-4; NIOSH 6015; ČSN ISO 7150-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"201514257901140204a62c76","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"21","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Workplace atmospheres","test_object_zh":"工作场所空气","test_object_cs":"Ovzduší pracovní","methodology":"Oznaczanie kwasu azotowego","methodology_en":"Determination of nitric acid","methodology_zh":"硝酸测定","methodology_cs":"Stanovení kyseliny dusičné","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"By spectrophotometry","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["By spectrophotometry"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kwasu azotowego\nMetoda spektrofotometryczna","reference":"A3-0814 (NIOSH 7903; ČSN ISO 7890-3)","norm_bases":["A3-0814","NIOSH 7903","ČSN ISO 7890-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Oznaczanie kwasu azotowego Metoda spektrofotometryczna Ovzduší pracovní Stanovení kyseliny dusičné spektrofotometricky A3-0814 (NIOSH 7903; ČSN ISO 7890-3) Powietrze na stanowiskach pracy Oznaczanie kwasu azotowego Metoda spektrofotometryczna Ovzdusi pracovni Stanoveni kyseliny dusicne spektrofotometricky A3-0814 (NIOSH 7903; CSN ISO 7890-3)","search_en":"Workplace atmospheres Determination of nitric acid By spectrophotometry A3-0814 (NIOSH 7903; ČSN ISO 7890-3)","search_zh":"工作场所空气 硝酸测定 分光光度法 A3-0814 (NIOSH 7903; ČSN ISO 7890-3)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"030119770b3dade437ffa346","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"22","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Workplace atmospheres","test_object_zh":"工作场所空气","test_object_cs":"Ovzduší pracovní","methodology":"Oznaczanie formaldehydu","methodology_en":"Determination of formaldehyde","methodology_zh":"甲醛测定","methodology_cs":"Stanovení formaldehydu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda HPLC z detekcją UV-VIS","technique_en":"HPLC method with UV VIS detection","technique_zh":"高效液相色谱法（紫外-可见检测）","technique_cs":"metodou HPLC s detekcí UV VIS","techniques":["Metoda HPLC z detekcją UV-VIS"],"techniques_en":["HPLC method with UV VIS detection"],"techniques_zh":["高效液相色谱法（紫外-可见检测）"],"techniques_cs":["metodou HPLC s detekcí UV VIS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie formaldehydu\nMetoda HPLC z detekcją UV-VIS","reference":"A3-2048 (ČSN EN ISO 16000-2; NIOSH 2016)","norm_bases":["A3-2048","ČSN EN ISO 16000-2","NIOSH 2016"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Oznaczanie formaldehydu Metoda HPLC z detekcją UV-VIS Ovzduší pracovní Stanovení formaldehydu metodou HPLC s detekcí UV VIS A3-2048 (ČSN EN ISO 16000-2; NIOSH 2016) Powietrze na stanowiskach pracy Oznaczanie formaldehydu Metoda HPLC z detekcja UV-VIS Ovzdusi pracovni Stanoveni formaldehydu metodou HPLC s detekci UV VIS A3-2048 (CSN EN ISO 16000-2; NIOSH 2016)","search_en":"Workplace atmospheres Determination of formaldehyde HPLC method with UV VIS detection A3-2048 (ČSN EN ISO 16000-2; NIOSH 2016)","search_zh":"工作场所空气 甲醛测定 高效液相色谱法（紫外-可见检测） A3-2048 (ČSN EN ISO 16000-2; NIOSH 2016)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"696e36de5becabb04f6f1e0b","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"23","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie azotu ogólnego (TN)","methodology_en":"Determination of TN","methodology_zh":"总氮（TN）测定","methodology_cs":"Stanovení TN","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Analizator chemiluminescencyjny","technique_en":"Chemiluminescence analyzer","technique_zh":"化学发光分析仪","technique_cs":"chemiluminiscenčním analyzátorem","techniques":["Analizator chemiluminescencyjny"],"techniques_en":["Chemiluminescence analyzer"],"techniques_zh":["化学发光分析仪"],"techniques_cs":["chemiluminiscenčním analyzátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu ogólnego (TN)\nAnalizator chemiluminescencyjny","reference":"A3-0922B (ČSN EN ISO 20236)","norm_bases":["A3-0922B","ČSN EN ISO 20236"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie azotu ogólnego (TN) Analizator chemiluminescencyjny Vody povrchové, odpadní Stanovení TN chemiluminiscenčním analyzátorem A3-0922B (ČSN EN ISO 20236) Wody powierzchniowe, scieki Oznaczanie azotu ogolnego (TN) Analizator chemiluminescencyjny Vody povrchove, odpadni Stanoveni TN chemiluminiscencnim analyzatorem A3-0922B (CSN EN ISO 20236)","search_en":"Surface water, waste water Determination of TN Chemiluminescence analyzer A3-0922B (ČSN EN ISO 20236)","search_zh":"地表水、废水 总氮（TN）测定 化学发光分析仪 A3-0922B (ČSN EN ISO 20236)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fe03382364420d63a2f61f28","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"24","test_object":"Wody powierzchniowe, ścieki","test_object_en":"Surface water, waste water","test_object_zh":"地表水、废水","test_object_cs":"Vody povrchové, odpadní","methodology":"Oznaczanie zawiesin ogólnych","methodology_en":"Determination of suspended solids","methodology_zh":"悬浮物测定","methodology_cs":"Stanovení nerozpuštěných látek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda wagowa","technique_en":"By gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["Metoda wagowa"],"techniques_en":["By gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesin ogólnych\nMetoda wagowa","reference":"A3-0431B (ČSN EN 872)","norm_bases":["A3-0431B","ČSN EN 872"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki Oznaczanie zawiesin ogólnych Metoda wagowa Vody povrchové, odpadní Stanovení nerozpuštěných látek gravimetricky A3-0431B (ČSN EN 872) Wody powierzchniowe, scieki Oznaczanie zawiesin ogolnych Metoda wagowa Vody povrchove, odpadni Stanoveni nerozpustenych latek gravimetricky A3-0431B (CSN EN 872)","search_en":"Surface water, waste water Determination of suspended solids By gravimetry A3-0431B (ČSN EN 872)","search_zh":"地表水、废水 悬浮物测定 重量法 A3-0431B (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c18dc032740ae05ba216bf48","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"1","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Pobieranie próbek ścieków","methodology_en":"Waste water sampling","methodology_zh":"废水采样","methodology_cs":"Vzorkování odpadních vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Automatyczne urządzenia do pobierania próbek","technique_en":"Automatic samplers","technique_zh":"自动采样器","technique_cs":"automatické vzorkovače","techniques":["Automatyczne urządzenia do pobierania próbek"],"techniques_en":["Automatic samplers"],"techniques_zh":["自动采样器"],"techniques_cs":["automatické vzorkovače"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków\nAutomatyczne urządzenia do pobierania próbek","reference":"O4-027/72 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 757315; ČSN EN 16479)","norm_bases":["O4-027/72","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14","ČSN 757315","ČSN EN 16479"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków Automatyczne urządzenia do pobierania próbek Odpadní vody Vzorkování odpadních vod automatické vzorkovače O4-027/72 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 757315; ČSN EN 16479) Scieki Pobieranie probek sciekow Automatyczne urzadzenia do pobierania probek Odpadni vody Vzorkovani odpadnich vod automaticke vzorkovace O4-027/72 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14; CSN 757315; CSN EN 16479)","search_en":"Waste water Waste water sampling Automatic samplers O4-027/72 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 757315; ČSN EN 16479)","search_zh":"废水 废水采样 自动采样器 O4-027/72 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 757315; ČSN EN 16479)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"88359e9164ecb6002152c47b","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"2","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Pobieranie próbek ścieków","methodology_en":"Waste water sampling","methodology_zh":"废水采样","methodology_cs":"Vzorkování odpadních vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Pobieranie ręczne","technique_en":"Manual sampling","technique_zh":"手工采样","technique_cs":"ruční odběry","techniques":["Pobieranie ręczne"],"techniques_en":["Manual sampling"],"techniques_zh":["手工采样"],"techniques_cs":["ruční odběry"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków\nPobieranie ręczne","reference":"O4-028/72 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 757315)","norm_bases":["O4-028/72","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14","ČSN 757315"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków Pobieranie ręczne Odpadní vody Vzorkování odpadních vod ruční odběry O4-028/72 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 757315) Scieki Pobieranie probek sciekow Pobieranie reczne Odpadni vody Vzorkovani odpadnich vod rucni odbery O4-028/72 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14; CSN 757315)","search_en":"Waste water Waste water sampling Manual sampling O4-028/72 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 757315)","search_zh":"废水 废水采样 手工采样 O4-028/72 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 757315)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"743dc65d7a447f3b1a5b17be","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"3","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchové vody","methodology":"Pobieranie próbek wód powierzchniowych","methodology_en":"Surface water sampling","methodology_zh":"地表水采样","methodology_cs":"Vzorkování povrchových vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Pobieranie ręczne","technique_en":"Manual sampling","technique_zh":"手工采样","technique_cs":"ruční odběry","techniques":["Pobieranie ręczne"],"techniques_en":["Manual sampling"],"techniques_zh":["手工采样"],"techniques_cs":["ruční odběry"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód powierzchniowych\nPobieranie ręczne","reference":"O4-031/72 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-6; ČSN EN ISO 5667-14)","norm_bases":["O4-031/72","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-4","ČSN ISO 5667-6","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Pobieranie próbek wód powierzchniowych Pobieranie ręczne Povrchové vody Vzorkování povrchových vod ruční odběry O4-031/72 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-6; ČSN EN ISO 5667-14) Wody powierzchniowe Pobieranie probek wod powierzchniowych Pobieranie reczne Povrchove vody Vzorkovani povrchovych vod rucni odbery O4-031/72 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-4; CSN ISO 5667-6; CSN EN ISO 5667-14)","search_en":"Surface water Surface water sampling Manual sampling O4-031/72 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-6; ČSN EN ISO 5667-14)","search_zh":"地表水 地表水采样 手工采样 O4-031/72 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-6; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8ef98e39f0bad4c49264bcb0","lab_id":"69ad52a4de79e566650fd3aa","country":"CZ","accr_number":"1370","accr_body":"ČIA","row_label":"4","test_object":"Powietrze na stanowiskach pracy","test_object_en":"Workplace atmospheres","test_object_zh":"工作场所空气","test_object_cs":"Ovzduší pracovní","methodology":"Pobieranie próbek powietrza na stanowiskach pracy","methodology_en":"Sampling of air from working environment","methodology_zh":"工作环境空气采样","methodology_cs":"Odběry vzorků ovzduší pracovního prostředí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Rurki sorpcyjne","technique_en":"Sorption tubes","technique_zh":"吸附管","technique_cs":"sorpční trubičky","techniques":["Rurki sorpcyjne"],"techniques_en":["Sorption tubes"],"techniques_zh":["吸附管"],"techniques_cs":["sorpční trubičky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza na stanowiskach pracy\nRurki sorpcyjne","reference":"O4-029/72 (ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16017-1; ČSN EN ISO 13137; NV č. 361/2007Sb.","norm_bases":["O4-029/72","ČSN EN 482","ČSN EN 689+AC","ČSN EN ISO 16017-1","ČSN EN ISO 13137","NV č. 361/2007Sb."],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy Pobieranie próbek powietrza na stanowiskach pracy Rurki sorpcyjne Ovzduší pracovní Odběry vzorků ovzduší pracovního prostředí sorpční trubičky O4-029/72 (ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16017-1; ČSN EN ISO 13137; NV č. 361/2007Sb. Powietrze na stanowiskach pracy Pobieranie probek powietrza na stanowiskach pracy Rurki sorpcyjne Ovzdusi pracovni Odbery vzorku ovzdusi pracovniho prostredi sorpcni trubicky O4-029/72 (CSN EN 482; CSN EN 689+AC; CSN EN ISO 16017-1; CSN EN ISO 13137; NV c. 361/2007Sb.","search_en":"Workplace atmospheres Sampling of air from working environment Sorption tubes O4-029/72 (ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16017-1; ČSN EN ISO 13137; NV č. 361/2007Sb.","search_zh":"工作场所空气 工作环境空气采样 吸附管 O4-029/72 (ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16017-1; ČSN EN ISO 13137; NV č. 361/2007Sb.","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}