{"lab":{"_id":"69ad52a4de79e566650fd392","accr_number":"1346","country":"CZ","accr_body":"ČIA","address":"areál ČOV Přerov - Henčlov, 750 02 Přerov","categories":["water"],"city":"Přerov","imported_at":"2026-03-08T10:42:44.590Z","methods_count":16,"name":"Vodovody a kanalizace Přerov, a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1346_108_2025_CS.pdf","1346_108_2025_EN.pdf"],"scope_summary":"Wykonywanie badań chemicznych ścieków, wód powierzchniowych i podziemnych oraz pobieranie próbek ścieków, wód powierzchniowych i osadów.","search_text":"vodovody a kanalizace přerov, a.s. areál čov přerov - henčlov, 750 02 přerov 1346","status":"active","updated_at":"2026-03-08T14:52:10.934Z","valid_from":"","valid_until":"05-03-2030","website":"www.vakpr.cz","location":{"type":"Point","coordinates":[17.451,49.4553]},"map_coord":[49.455378,17.450862],"map_geo":"nominatim-city","certificate_date":"05.03.2025","certificate_no":"108/2025","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wykonywanie badań chemicznych ścieków, wód powierzchniowych i podziemnych oraz pobieranie próbek ścieków, wód powierzchniowych i osadów.","en":"Chemical testing of waste, surface and ground water and sampling of waste water, surface water and sludge.","zh":"废水、地表水、地下水的化学检测以及废水、地表水和污泥的采样。","cs":"Provádění chemických zkoušek odpadních, povrchových, podzemních vod a vzorkování odpadních, povrchových vod a kalů."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"laboratorium ścieków","lab_division_cs":"laboratoř odpadních vod","lab_division_en":"Wastewater Laboratory","lab_division_zh":"废水实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The laboratory is competent to perform independent sampling.","zh":"实验室有能力独立进行采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."}],"source_lang":"cs","source_pdf_sha256":"29bac69abd394c219ff0c57da72335730f91aca2cfadcdd6669bd4bbc6bbe1e9","source_pdf_url":"https://www.cai.cz/OA/pdf/P108_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"27a08152ec6561ad8276d93f","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"1","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dichromianową (ChZT-Cr) fotometrycznie","methodology_en":"Determination of chemical oxygen demand by dichromate (CODCr) by photometry","methodology_zh":"光度法测定重铬酸盐化学需氧量(CODCr)","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem (CHSKCr) fotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dichromianową (ChZT-Cr) fotometrycznie","reference":"SOP č. 10 (ČSN ISO 15705)","norm_bases":["SOP č. 10","ČSN ISO 15705"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie chemicznego zapotrzebowania na tlen metodą dichromianową (ChZT-Cr) fotometrycznie Odpadní, povrchová a podzemní voda Stanovení chemické spotřeby kyslíku dichromanem (CHSKCr) fotometricky SOP č. 10 (ČSN ISO 15705) Scieki, woda powierzchniowa i podziemna Oznaczanie chemicznego zapotrzebowania na tlen metoda dichromianowa (ChZT-Cr) fotometrycznie Odpadni, povrchova a podzemni voda Stanoveni chemicke spotreby kysliku dichromanem (CHSKCr) fotometricky SOP c. 10 (CSN ISO 15705)","search_en":"Waste, surface and ground water Determination of chemical oxygen demand by dichromate (CODCr) by photometry SOP č. 10 (ČSN ISO 15705)","search_zh":"废水、地表水和地下水 光度法测定重铬酸盐化学需氧量(CODCr) SOP č. 10 (ČSN ISO 15705)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4c7b6c4a82b4e241df89d383","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"2","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie substancji rozpuszczonych suszonych metodą wagową","methodology_en":"Determination of dried dissolved solids by gravimetry","methodology_zh":"重量法测定溶解性固体（烘干）","methodology_cs":"Stanovení rozpuštěných látek sušených gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych suszonych metodą wagową","reference":"SOP č. 14 (ČSN 75 7346)","norm_bases":["SOP č. 14","ČSN 75 7346"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie substancji rozpuszczonych suszonych metodą wagową Odpadní, povrchová a podzemní voda Stanovení rozpuštěných látek sušených gravimetricky SOP č. 14 (ČSN 75 7346) Scieki, woda powierzchniowa i podziemna Oznaczanie substancji rozpuszczonych suszonych metoda wagowa Odpadni, povrchova a podzemni voda Stanoveni rozpustenych latek susenych gravimetricky SOP c. 14 (CSN 75 7346)","search_en":"Waste, surface and ground water Determination of dried dissolved solids by gravimetry SOP č. 14 (ČSN 75 7346)","search_zh":"废水、地表水和地下水 重量法测定溶解性固体（烘干） SOP č. 14 (ČSN 75 7346)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6316af09699003f84b0666aa","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"3","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie rozpuszczonych soli nieorganicznych metodą wagową","methodology_en":"Determination of dissolved inorganic salts by gravimetry","methodology_zh":"重量法测定溶解性无机盐","methodology_cs":"Stanovení rozpuštěných anorganických solí gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rozpuszczonych soli nieorganicznych metodą wagową","reference":"SOP 15 (ČSN 75 7347)","norm_bases":["SOP 15","ČSN 75 7347"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie rozpuszczonych soli nieorganicznych metodą wagową Odpadní, povrchová a podzemní voda Stanovení rozpuštěných anorganických solí gravimetricky SOP 15 (ČSN 75 7347) Scieki, woda powierzchniowa i podziemna Oznaczanie rozpuszczonych soli nieorganicznych metoda wagowa Odpadni, povrchova a podzemni voda Stanoveni rozpustenych anorganickych soli gravimetricky SOP 15 (CSN 75 7347)","search_en":"Waste, surface and ground water Determination of dissolved inorganic salts by gravimetry SOP 15 (ČSN 75 7347)","search_zh":"废水、地表水和地下水 重量法测定溶解性无机盐 SOP 15 (ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0e48fa187fc340b0ff957824","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"4","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie jonów amonowych metodą miareczkową po destylacji oraz azotu amonowego i nieorganicznego obliczeniowo","methodology_en":"Determination of ammonium ions by titration after distillation and ammoniacal and inorganic nitrogen by calculation","methodology_zh":"蒸馏后滴定法测定铵离子，并计算氨氮和无机氮","methodology_cs":"Stanovení amonných iontů titračně po destilaci a amoniakálního a anorganického dusíku dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych metodą miareczkową po destylacji oraz azotu amonowego i nieorganicznego obliczeniowo","reference":"SOP č. 1 (ČSN ISO 5664)","norm_bases":["SOP č. 1","ČSN ISO 5664"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie jonów amonowych metodą miareczkową po destylacji oraz azotu amonowego i nieorganicznego obliczeniowo Odpadní, povrchová a podzemní voda Stanovení amonných iontů titračně po destilaci a amoniakálního a anorganického dusíku dopočtem SOP č. 1 (ČSN ISO 5664) Scieki, woda powierzchniowa i podziemna Oznaczanie jonow amonowych metoda miareczkowa po destylacji oraz azotu amonowego i nieorganicznego obliczeniowo Odpadni, povrchova a podzemni voda Stanoveni amonnych iontu titracne po destilaci a amoniakalniho a anorganickeho dusiku dopoctem SOP c. 1 (CSN ISO 5664)","search_en":"Waste, surface and ground water Determination of ammonium ions by titration after distillation and ammoniacal and inorganic nitrogen by calculation SOP č. 1 (ČSN ISO 5664)","search_zh":"废水、地表水和地下水 蒸馏后滴定法测定铵离子，并计算氨氮和无机氮 SOP č. 1 (ČSN ISO 5664)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"279772b139e05dd416136f7c","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"5","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie azotynów fotometrycznie i azotu azotynowego obliczeniowo","methodology_en":"Determination of nitrites by photometry and nitrite nitrogen by calculation","methodology_zh":"光度法测定亚硝酸盐并计算亚硝酸盐氮","methodology_cs":"Stanovení dusitanů fotometricky a dusitanového dusíku dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotynów fotometrycznie i azotu azotynowego obliczeniowo","reference":"SOP č. 5 (ČSN EN 26777)","norm_bases":["SOP č. 5","ČSN EN 26777"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie azotynów fotometrycznie i azotu azotynowego obliczeniowo Odpadní, povrchová a podzemní voda Stanovení dusitanů fotometricky a dusitanového dusíku dopočtem SOP č. 5 (ČSN EN 26777) Scieki, woda powierzchniowa i podziemna Oznaczanie azotynow fotometrycznie i azotu azotynowego obliczeniowo Odpadni, povrchova a podzemni voda Stanoveni dusitanu fotometricky a dusitanoveho dusiku dopoctem SOP c. 5 (CSN EN 26777)","search_en":"Waste, surface and ground water Determination of nitrites by photometry and nitrite nitrogen by calculation SOP č. 5 (ČSN EN 26777)","search_zh":"废水、地表水和地下水 光度法测定亚硝酸盐并计算亚硝酸盐氮 SOP č. 5 (ČSN EN 26777)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"66840d10c1a0b88eb009f0f7","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"6","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie zawiesiny ogólnej metodą wagową","methodology_en":"Determination of suspended solids by gravimetry","methodology_zh":"重量法测定悬浮物","methodology_cs":"Stanovení nerozpuštěných látek gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesiny ogólnej metodą wagową","reference":"SOP č. 2 (ČSN EN 872)","norm_bases":["SOP č. 2","ČSN EN 872"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie zawiesiny ogólnej metodą wagową Odpadní, povrchová a podzemní voda Stanovení nerozpuštěných látek gravimetricky SOP č. 2 (ČSN EN 872) Scieki, woda powierzchniowa i podziemna Oznaczanie zawiesiny ogolnej metoda wagowa Odpadni, povrchova a podzemni voda Stanoveni nerozpustenych latek gravimetricky SOP c. 2 (CSN EN 872)","search_en":"Waste, surface and ground water Determination of suspended solids by gravimetry SOP č. 2 (ČSN EN 872)","search_zh":"废水、地表水和地下水 重量法测定悬浮物 SOP č. 2 (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"82275a08d5282c304703c8a4","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"7","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie pH metodą elektrometryczną","methodology_en":"Determination of pH by electrometry","methodology_zh":"电测法测定pH值","methodology_cs":"Stanovení pH elektrometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą elektrometryczną","reference":"SOP č. 4 (ČSN ISO 10523)","norm_bases":["SOP č. 4","ČSN ISO 10523"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie pH metodą elektrometryczną Odpadní, povrchová a podzemní voda Stanovení pH elektrometricky SOP č. 4 (ČSN ISO 10523) Scieki, woda powierzchniowa i podziemna Oznaczanie pH metoda elektrometryczna Odpadni, povrchova a podzemni voda Stanoveni pH elektrometricky SOP c. 4 (CSN ISO 10523)","search_en":"Waste, surface and ground water Determination of pH by electrometry SOP č. 4 (ČSN ISO 10523)","search_zh":"废水、地表水和地下水 电测法测定pH值 SOP č. 4 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2587929a8b87763aed0fc614","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"8","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie biochemicznego zapotrzebowania na tlen (BZT5) metodą elektrochemiczną","methodology_en":"Determination of biochemical oxygen demand (BOD5) by electrochemical method","methodology_zh":"电化学法测定生化需氧量(BOD5)","methodology_cs":"Stanovení biochemické spotřeby kyslíku (BSK5) elektrochemicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania na tlen (BZT5) metodą elektrochemiczną","reference":"SOP č. 3 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN EN ISO 5814)","norm_bases":["SOP č. 3","ČSN EN ISO 5815-1","ČSN EN 1899-2","ČSN EN ISO 5814"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie biochemicznego zapotrzebowania na tlen (BZT5) metodą elektrochemiczną Odpadní, povrchová a podzemní voda Stanovení biochemické spotřeby kyslíku (BSK5) elektrochemicky SOP č. 3 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN EN ISO 5814) Scieki, woda powierzchniowa i podziemna Oznaczanie biochemicznego zapotrzebowania na tlen (BZT5) metoda elektrochemiczna Odpadni, povrchova a podzemni voda Stanoveni biochemicke spotreby kysliku (BSK5) elektrochemicky SOP c. 3 (CSN EN ISO 5815-1; CSN EN 1899-2; CSN EN ISO 5814)","search_en":"Waste, surface and ground water Determination of biochemical oxygen demand (BOD5) by electrochemical method SOP č. 3 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN EN ISO 5814)","search_zh":"废水、地表水和地下水 电化学法测定生化需氧量(BOD5) SOP č. 3 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN EN ISO 5814)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e65c9d9254665a6aea88109b","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"9","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie jonów amonowych fotometrycznie i azotu amonowego obliczeniowo","methodology_en":"Determination of ammonium ions by photometry and ammoniacal nitrogen by calculation","methodology_zh":"光度法测定铵离子并计算氨氮","methodology_cs":"Stanovení amonných iontů fotometricky a amoniakálního dusíku dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych fotometrycznie i azotu amonowego obliczeniowo","reference":"SOP č. 8 (ČSN ISO 7150-1)","norm_bases":["SOP č. 8","ČSN ISO 7150-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie jonów amonowych fotometrycznie i azotu amonowego obliczeniowo Odpadní, povrchová a podzemní voda Stanovení amonných iontů fotometricky a amoniakálního dusíku dopočtem SOP č. 8 (ČSN ISO 7150-1) Scieki, woda powierzchniowa i podziemna Oznaczanie jonow amonowych fotometrycznie i azotu amonowego obliczeniowo Odpadni, povrchova a podzemni voda Stanoveni amonnych iontu fotometricky a amoniakalniho dusiku dopoctem SOP c. 8 (CSN ISO 7150-1)","search_en":"Waste, surface and ground water Determination of ammonium ions by photometry and ammoniacal nitrogen by calculation SOP č. 8 (ČSN ISO 7150-1)","search_zh":"废水、地表水和地下水 光度法测定铵离子并计算氨氮 SOP č. 8 (ČSN ISO 7150-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7688fb7f195a4d45016440ec","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"10","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie azotanów fotometrycznie i azotu azotanowego obliczeniowo","methodology_en":"Determination of nitrates by photometry and nitrate nitrogen by calculation","methodology_zh":"光度法测定硝酸盐并计算硝酸盐氮","methodology_cs":"Stanovení dusičnanů fotometricky a dusičnanového dusíku dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotanów fotometrycznie i azotu azotanowego obliczeniowo","reference":"SOP č. 6 (ČSN 75 7455)","norm_bases":["SOP č. 6","ČSN 75 7455"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie azotanów fotometrycznie i azotu azotanowego obliczeniowo Odpadní, povrchová a podzemní voda Stanovení dusičnanů fotometricky a dusičnanového dusíku dopočtem SOP č. 6 (ČSN 75 7455) Scieki, woda powierzchniowa i podziemna Oznaczanie azotanow fotometrycznie i azotu azotanowego obliczeniowo Odpadni, povrchova a podzemni voda Stanoveni dusicnanu fotometricky a dusicnanoveho dusiku dopoctem SOP c. 6 (CSN 75 7455)","search_en":"Waste, surface and ground water Determination of nitrates by photometry and nitrate nitrogen by calculation SOP č. 6 (ČSN 75 7455)","search_zh":"废水、地表水和地下水 光度法测定硝酸盐并计算硝酸盐氮 SOP č. 6 (ČSN 75 7455)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"805734ab749da6e8936a1a7d","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"11","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie azotu ogólnego po mineralizacji utleniającej fotometrycznie","methodology_en":"Determination of total nitrogen after oxidative digestion by photometry","methodology_zh":"氧化消解后光度法测定总氮","methodology_cs":"Stanovení dusíku celkového po oxidační mineralizaci fotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu ogólnego po mineralizacji utleniającej fotometrycznie","reference":"SOP č. 7 (ČSN EN ISO 11905-1; ČSN 75 7455)","norm_bases":["SOP č. 7","ČSN EN ISO 11905-1","ČSN 75 7455"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie azotu ogólnego po mineralizacji utleniającej fotometrycznie Odpadní, povrchová a podzemní voda Stanovení dusíku celkového po oxidační mineralizaci fotometricky SOP č. 7 (ČSN EN ISO 11905-1; ČSN 75 7455) Scieki, woda powierzchniowa i podziemna Oznaczanie azotu ogolnego po mineralizacji utleniajacej fotometrycznie Odpadni, povrchova a podzemni voda Stanoveni dusiku celkoveho po oxidacni mineralizaci fotometricky SOP c. 7 (CSN EN ISO 11905-1; CSN 75 7455)","search_en":"Waste, surface and ground water Determination of total nitrogen after oxidative digestion by photometry SOP č. 7 (ČSN EN ISO 11905-1; ČSN 75 7455)","search_zh":"废水、地表水和地下水 氧化消解后光度法测定总氮 SOP č. 7 (ČSN EN ISO 11905-1; ČSN 75 7455)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5763cb0576ef8bef4b094489","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"12","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie temperatury","methodology_en":"Determination of temperature","methodology_zh":"温度的测定","methodology_cs":"Stanovení teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury","reference":"SOP č. 13 (ČSN 75 7342)","norm_bases":["SOP č. 13","ČSN 75 7342"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie temperatury Odpadní, povrchová a podzemní voda Stanovení teploty SOP č. 13 (ČSN 75 7342) Scieki, woda powierzchniowa i podziemna Oznaczanie temperatury Odpadni, povrchova a podzemni voda Stanoveni teploty SOP c. 13 (CSN 75 7342)","search_en":"Waste, surface and ground water Determination of temperature SOP č. 13 (ČSN 75 7342)","search_zh":"废水、地表水和地下水 温度的测定 SOP č. 13 (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"857d611379e9efb770d5cba3","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"13","test_object":"Ścieki, woda powierzchniowa i podziemna","test_object_en":"Waste, surface and ground water","test_object_zh":"废水、地表水和地下水","test_object_cs":"Odpadní, povrchová a podzemní voda","methodology":"Oznaczanie fosforanów zestawem firmy Merck fotometrycznie i fosforu ogólnego po mineralizacji obliczeniowo","methodology_en":"Determination of phosphates by photometry using a Merck kit and total phosphorus after digestion by calculation","methodology_zh":"用Merck试剂盒光度法测定磷酸盐并计算消解后总磷","methodology_cs":"Stanovení fosforečnanů setem fy Merck fotometricky a fosforu celkového po mineralizaci dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforanów zestawem firmy Merck fotometrycznie i fosforu ogólnego po mineralizacji obliczeniowo","reference":"SOP č. 11 (ČSN EN ISO 6878; návod firmy Merck)","norm_bases":["SOP č. 11","ČSN EN ISO 6878","návod firmy Merck"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda powierzchniowa i podziemna Oznaczanie fosforanów zestawem firmy Merck fotometrycznie i fosforu ogólnego po mineralizacji obliczeniowo Odpadní, povrchová a podzemní voda Stanovení fosforečnanů setem fy Merck fotometricky a fosforu celkového po mineralizaci dopočtem SOP č. 11 (ČSN EN ISO 6878; návod firmy Merck) Scieki, woda powierzchniowa i podziemna Oznaczanie fosforanow zestawem firmy Merck fotometrycznie i fosforu ogolnego po mineralizacji obliczeniowo Odpadni, povrchova a podzemni voda Stanoveni fosforecnanu setem fy Merck fotometricky a fosforu celkoveho po mineralizaci dopoctem SOP c. 11 (CSN EN ISO 6878; navod firmy Merck)","search_en":"Waste, surface and ground water Determination of phosphates by photometry using a Merck kit and total phosphorus after digestion by calculation SOP č. 11 (ČSN EN ISO 6878; návod firmy Merck)","search_zh":"废水、地表水和地下水 用Merck试剂盒光度法测定磷酸盐并计算消解后总磷 SOP č. 11 (ČSN EN ISO 6878; návod firmy Merck)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f64de73e5cc164ff24761c34","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"1","test_object":"Ścieki","test_object_en":"Wastewater","test_object_zh":"废水","test_object_cs":"Odpadní voda","methodology":"Pobieranie próbek ścieków (pobór ręczny, pobór automatycznym próbnikiem)","methodology_en":"Sampling of wastewater (manual sampling, sampling by automatic sampler)","methodology_zh":"废水采样（手工采样、自动采样器采样）","methodology_cs":"Odběr vzorků odpadních vod (ruční odběr, odběr automatickým vzorkovačem)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków (pobór ręczny, pobór automatycznym próbnikiem)","reference":"SOP č. 1V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","norm_bases":["SOP č. 1V","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków (pobór ręczny, pobór automatycznym próbnikiem) Odpadní voda Odběr vzorků odpadních vod (ruční odběr, odběr automatickým vzorkovačem) SOP č. 1V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14) Scieki Pobieranie probek sciekow (pobor reczny, pobor automatycznym probnikiem) Odpadni voda Odber vzorku odpadnich vod (rucni odber, odber automatickym vzorkovacem) SOP c. 1V (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14)","search_en":"Wastewater Sampling of wastewater (manual sampling, sampling by automatic sampler) SOP č. 1V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","search_zh":"废水 废水采样（手工采样、自动采样器采样） SOP č. 1V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6aab70e62b051805f91f808c","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"2","test_object":"Woda powierzchniowa","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchová voda","methodology":"Pobieranie próbek wód powierzchniowych (pobór ręczny)","methodology_en":"Sampling of surface water (manual sampling)","methodology_zh":"地表水采样（手工采样）","methodology_cs":"Odběr vzorků povrchových vod (ruční odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód powierzchniowych (pobór ręczny)","reference":"SOP č. 2V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14)","norm_bases":["SOP č. 2V","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-6","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda powierzchniowa Pobieranie próbek wód powierzchniowych (pobór ręczny) Povrchová voda Odběr vzorků povrchových vod (ruční odběr) SOP č. 2V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14) Woda powierzchniowa Pobieranie probek wod powierzchniowych (pobor reczny) Povrchova voda Odber vzorku povrchovych vod (rucni odber) SOP c. 2V (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-6; CSN EN ISO 5667-14)","search_en":"Surface water Sampling of surface water (manual sampling) SOP č. 2V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14)","search_zh":"地表水 地表水采样（手工采样） SOP č. 2V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6735e44aea86820b6650ea3c","lab_id":"69ad52a4de79e566650fd392","country":"CZ","accr_number":"1346","accr_body":"ČIA","row_label":"3","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","test_object_zh":"污水处理厂污泥","test_object_cs":"Čistírenské kaly","methodology":"Pobieranie próbek osadów","methodology_en":"Sampling of sludge","methodology_zh":"污泥采样","methodology_cs":"Odběr vzorků kalů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek osadów","reference":"SOP č. 4V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15)","norm_bases":["SOP č. 4V","ČSN EN ISO 5667-1","ČSN EN ISO 5667-13","ČSN EN ISO 5667-15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady ściekowe Pobieranie próbek osadów Čistírenské kaly Odběr vzorků kalů SOP č. 4V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15) Osady sciekowe Pobieranie probek osadow Cistirenske kaly Odber vzorku kalu SOP c. 4V (CSN EN ISO 5667-1; CSN EN ISO 5667-13; CSN EN ISO 5667-15)","search_en":"Sewage sludge Sampling of sludge SOP č. 4V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15)","search_zh":"污水处理厂污泥 污泥采样 SOP č. 4V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}