{"lab":{"_id":"69ad52a4de79e566650fd380","country":"CZ","accr_number":"1325","accr_body":"ČIA","address":"Cejl 157/50, Zábrdovice, 602 00 Brno","categories":["pharma","metrology"],"city":"Brno","imported_at":"2026-03-08T10:42:44.590Z","methods_count":9,"name":"BMT Medical Technology s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1325_113_2025_CS.pdf","1325_113_2025_EN.pdf"],"scope_summary":"Badania sterylizatorów parowych i na gorące powietrze oraz urządzeń techniki cieplnej.","search_text":"bmt medical technology s.r.o. cejl 157/50, zábrdovice, 602 00 brno 1325","status":"active","updated_at":"2026-03-08T14:52:10.640Z","valid_from":"","valid_until":"10-03-2030","website":"www.bmt.cz","location":{"type":"Point","coordinates":[16.6068,49.1951]},"map_coord":[49.198548,16.622154],"map_geo":"nominatim-street","certificate_date":"10.03.2025","certificate_no":"113/2025","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania sterylizatorów parowych i na gorące powietrze oraz urządzeń techniki cieplnej.","en":"Tests of steam and hot air sterilizers and temperature control technology.","zh":"蒸汽和热空气灭菌器及温控技术设备的试验。","cs":"Zkoušky parních a horkovzdušných sterilizátorů a přístrojů teplotní techniky."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze Sterylizatorów Parowych i na Gorące Powietrze oraz Urządzeń Techniki Cieplnej","lab_division_cs":"Zkušební laboratoř parních a horkovzdušných sterilizátorů a přístrojů teplotní techniky","lab_division_en":"Testing Laboratory of Steam and Hot Air Sterilizers and Heat Technology Devices","lab_division_zh":"蒸汽和热空气灭菌器及热工技术设备检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"QPP","pl":"Procedura robocza BMT Medical Technology s.r.o.","en":"BMT Medical Technology s.r.o. Working Procedure","zh":"BMT Medical Technology s.r.o. 作业程序","cs":"Pracovní postup BMT Medical Technology s.r.o."},{"abbr":"VYR","pl":"Wytyczna SÚKL (Państwowy Instytut Kontroli Leków, Czechy)","en":"SÚKL Guideline (State Institute for Drug Control)","zh":"SÚKL 指南（捷克国家药品管理局）","cs":"Pokyn SÚKL (Státní ústav pro kontrolu léčiv)"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"ff192cc20139b06c7a8ea685b307996f2c9fa1cc0ae61886eaccb93f922dd5ba","source_pdf_url":"https://www.cai.cz/OA/pdf/P113_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P113_2025_EN.pdf"},"methods":[{"_id":"252394de26b0830335ce8abc","lab_id":"69ad52a4de79e566650fd380","country":"CZ","accr_number":"1325","accr_body":"ČIA","row_label":"1","test_object":"Sterylizatory parowe","test_object_en":"Steam sterilizers","test_object_zh":"蒸汽灭菌器","test_object_cs":"Parní sterilizátory","methodology":"Próba przenikania powietrza (szczelności)","methodology_en":"Air leakage test","methodology_zh":"空气泄漏试验","methodology_cs":"Zkouška pronikání vzduchu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba przenikania powietrza (szczelności)","reference":"QPP 10-52 (ČSN EN 285+A1, čl. 18; ČSN EN 13060+A1, čl. 10.2)","norm_bases":["QPP 10-52","ČSN EN 285+A1","ČSN EN 13060+A1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sterylizatory parowe Próba przenikania powietrza (szczelności) Parní sterilizátory Zkouška pronikání vzduchu QPP 10-52 (ČSN EN 285+A1, čl. 18; ČSN EN 13060+A1, čl. 10.2) Sterylizatory parowe Proba przenikania powietrza (szczelnosci) Parni sterilizatory Zkouska pronikani vzduchu QPP 10-52 (CSN EN 285+A1, cl. 18; CSN EN 13060+A1, cl. 10.2)","search_en":"Steam sterilizers Air leakage test QPP 10-52 (ČSN EN 285+A1, čl. 18; ČSN EN 13060+A1, čl. 10.2)","search_zh":"蒸汽灭菌器 空气泄漏试验 QPP 10-52 (ČSN EN 285+A1, čl. 18; ČSN EN 13060+A1, čl. 10.2)","categories":["pharma","metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"08be30022ba5025f8c5adc85","lab_id":"69ad52a4de79e566650fd380","country":"CZ","accr_number":"1325","accr_body":"ČIA","row_label":"2","test_object":"Sterylizatory parowe","test_object_en":"Steam sterilizers","test_object_zh":"蒸汽灭菌器","test_object_cs":"Parní sterilizátory","methodology":"Próba termometryczna","methodology_en":"Thermometric test","methodology_zh":"测温试验","methodology_cs":"Termometrická zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba termometryczna","reference":"QPP 10-53 (ČSN EN 285+A1, čl. 16)","norm_bases":["QPP 10-53","ČSN EN 285+A1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sterylizatory parowe Próba termometryczna Parní sterilizátory Termometrická zkouška QPP 10-53 (ČSN EN 285+A1, čl. 16) Sterylizatory parowe Proba termometryczna Parni sterilizatory Termometricka zkouska QPP 10-53 (CSN EN 285+A1, cl. 16)","search_en":"Steam sterilizers Thermometric test QPP 10-53 (ČSN EN 285+A1, čl. 16)","search_zh":"蒸汽灭菌器 测温试验 QPP 10-53 (ČSN EN 285+A1, čl. 16)","categories":["pharma","metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3783b202604abb338bc22da9","lab_id":"69ad52a4de79e566650fd380","country":"CZ","accr_number":"1325","accr_body":"ČIA","row_label":"3","test_object":"Sterylizatory parowe","test_object_en":"Steam sterilizers","test_object_zh":"蒸汽灭菌器","test_object_cs":"Parní sterilizátory","methodology":"Próba dynamiki ciśnienia w komorze","methodology_en":"Dynamic chamber pressure test","methodology_zh":"腔室压力动态试验","methodology_cs":"Zkouška dynamiky tlaku v komoře","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba dynamiki ciśnienia w komorze","reference":"QPP 10-54 (ČSN EN 285+A1, čl. 22; ČSN EN 13060+A1, čl. 10.3)","norm_bases":["QPP 10-54","ČSN EN 285+A1","ČSN EN 13060+A1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sterylizatory parowe Próba dynamiki ciśnienia w komorze Parní sterilizátory Zkouška dynamiky tlaku v komoře QPP 10-54 (ČSN EN 285+A1, čl. 22; ČSN EN 13060+A1, čl. 10.3) Sterylizatory parowe Proba dynamiki cisnienia w komorze Parni sterilizatory Zkouska dynamiky tlaku v komore QPP 10-54 (CSN EN 285+A1, cl. 22; CSN EN 13060+A1, cl. 10.3)","search_en":"Steam sterilizers Dynamic chamber pressure test QPP 10-54 (ČSN EN 285+A1, čl. 22; ČSN EN 13060+A1, čl. 10.3)","search_zh":"蒸汽灭菌器 腔室压力动态试验 QPP 10-54 (ČSN EN 285+A1, čl. 22; ČSN EN 13060+A1, čl. 10.3)","categories":["pharma","metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2d3f11aacd00ee6a702af57c","lab_id":"69ad52a4de79e566650fd380","country":"CZ","accr_number":"1325","accr_body":"ČIA","row_label":"4","test_object":"Sterylizatory parowe","test_object_en":"Steam sterilizers","test_object_zh":"蒸汽灭菌器","test_object_cs":"Parní sterilizátory","methodology":"Pomiar ciśnienia i profilu temperatury w pustej komorze","methodology_en":"Measurement of pressure and temperature profile in empty chamber","methodology_zh":"空腔室压力和温度分布测量","methodology_cs":"Měření tlaku a teplotního profilu v prázdné komoře","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar ciśnienia i profilu temperatury w pustej komorze","reference":"QPP 10-56 (ČSN EN 554:1996, čl. 5.2; VYR-34:2005, čl. 2.1)","norm_bases":["QPP 10-56","ČSN EN 554:1996","VYR-34:2005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sterylizatory parowe Pomiar ciśnienia i profilu temperatury w pustej komorze Parní sterilizátory Měření tlaku a teplotního profilu v prázdné komoře QPP 10-56 (ČSN EN 554:1996, čl. 5.2; VYR-34:2005, čl. 2.1) Sterylizatory parowe Pomiar cisnienia i profilu temperatury w pustej komorze Parni sterilizatory Mereni tlaku a teplotniho profilu v prazdne komore QPP 10-56 (CSN EN 554:1996, cl. 5.2; VYR-34:2005, cl. 2.1)","search_en":"Steam sterilizers Measurement of pressure and temperature profile in empty chamber QPP 10-56 (ČSN EN 554:1996, čl. 5.2; VYR-34:2005, čl. 2.1)","search_zh":"蒸汽灭菌器 空腔室压力和温度分布测量 QPP 10-56 (ČSN EN 554:1996, čl. 5.2; VYR-34:2005, čl. 2.1)","categories":["pharma","metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3d5f9d9c66eeb6939562decb","lab_id":"69ad52a4de79e566650fd380","country":"CZ","accr_number":"1325","accr_body":"ČIA","row_label":"5","test_object":"Sterylizatory parowe","test_object_en":"Steam sterilizers","test_object_zh":"蒸汽灭菌器","test_object_cs":"Parní sterilizátory","methodology":"Pomiar ciśnienia i rozkładu temperatury w komorze z wsadem","methodology_en":"Measurement of pressure and temperature distribution in chamber with the load","methodology_zh":"装载腔室压力和温度分布测量","methodology_cs":"Měření tlaku a distribuce teploty v komoře se vsázkou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar ciśnienia i rozkładu temperatury w komorze z wsadem","reference":"QPP 10-57 (ČSN EN 554:1996, čl. 5.3; VYR-34:2005, čl. 2.1)","norm_bases":["QPP 10-57","ČSN EN 554:1996","VYR-34:2005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sterylizatory parowe Pomiar ciśnienia i rozkładu temperatury w komorze z wsadem Parní sterilizátory Měření tlaku a distribuce teploty v komoře se vsázkou QPP 10-57 (ČSN EN 554:1996, čl. 5.3; VYR-34:2005, čl. 2.1) Sterylizatory parowe Pomiar cisnienia i rozkladu temperatury w komorze z wsadem Parni sterilizatory Mereni tlaku a distribuce teploty v komore se vsazkou QPP 10-57 (CSN EN 554:1996, cl. 5.3; VYR-34:2005, cl. 2.1)","search_en":"Steam sterilizers Measurement of pressure and temperature distribution in chamber with the load QPP 10-57 (ČSN EN 554:1996, čl. 5.3; VYR-34:2005, čl. 2.1)","search_zh":"蒸汽灭菌器 装载腔室压力和温度分布测量 QPP 10-57 (ČSN EN 554:1996, čl. 5.3; VYR-34:2005, čl. 2.1)","categories":["pharma","metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5854f4a42977f74324a92d11","lab_id":"69ad52a4de79e566650fd380","country":"CZ","accr_number":"1325","accr_body":"ČIA","row_label":"6","test_object":"Sterylizatory na gorące powietrze, urządzenia techniki cieplnej","test_object_en":"Hot air sterilizers, heat technology devices","test_object_zh":"热空气灭菌器、热工技术设备","test_object_cs":"Horkovzdušné sterilizátory, přístroje teplotní techniky","methodology":"Pomiar temperatury","methodology_en":"Measurement of temperature","methodology_zh":"温度测量","methodology_cs":"Měření teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar temperatury","reference":"QPP 10-27 (ČSN EN IEC 60068-3-5 ed. 2; DIN 12 880)","norm_bases":["QPP 10-27","ČSN EN IEC 60068-3-5 ed. 2","DIN 12 880"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sterylizatory na gorące powietrze, urządzenia techniki cieplnej Pomiar temperatury Horkovzdušné sterilizátory, přístroje teplotní techniky Měření teploty QPP 10-27 (ČSN EN IEC 60068-3-5 ed. 2; DIN 12 880) Sterylizatory na gorace powietrze, urzadzenia techniki cieplnej Pomiar temperatury Horkovzdusne sterilizatory, pristroje teplotni techniky Mereni teploty QPP 10-27 (CSN EN IEC 60068-3-5 ed. 2; DIN 12 880)","search_en":"Hot air sterilizers, heat technology devices Measurement of temperature QPP 10-27 (ČSN EN IEC 60068-3-5 ed. 2; DIN 12 880)","search_zh":"热空气灭菌器、热工技术设备 温度测量 QPP 10-27 (ČSN EN IEC 60068-3-5 ed. 2; DIN 12 880)","categories":["pharma","metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eee1e8ed656a1b25153930c7","lab_id":"69ad52a4de79e566650fd380","country":"CZ","accr_number":"1325","accr_body":"ČIA","row_label":"7","test_object":"Sterylizatory na gorące powietrze, urządzenia techniki cieplnej","test_object_en":"Hot air sterilizers, heat technology devices","test_object_zh":"热空气灭菌器、热工技术设备","test_object_cs":"Horkovzdušné sterilizátory, přístroje teplotní techniky","methodology":"Pomiar profilu temperatury w pustej komorze","methodology_en":"Measurement of temperature profile in empty chamber","methodology_zh":"空腔室温度分布测量","methodology_cs":"Měření teplotního profilu v prázdné komoře","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar profilu temperatury w pustej komorze","reference":"QPP 10-91 (VYR-34:2005, čl. 2.2)","norm_bases":["QPP 10-91","VYR-34:2005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sterylizatory na gorące powietrze, urządzenia techniki cieplnej Pomiar profilu temperatury w pustej komorze Horkovzdušné sterilizátory, přístroje teplotní techniky Měření teplotního profilu v prázdné komoře QPP 10-91 (VYR-34:2005, čl. 2.2) Sterylizatory na gorace powietrze, urzadzenia techniki cieplnej Pomiar profilu temperatury w pustej komorze Horkovzdusne sterilizatory, pristroje teplotni techniky Mereni teplotniho profilu v prazdne komore QPP 10-91 (VYR-34:2005, cl. 2.2)","search_en":"Hot air sterilizers, heat technology devices Measurement of temperature profile in empty chamber QPP 10-91 (VYR-34:2005, čl. 2.2)","search_zh":"热空气灭菌器、热工技术设备 空腔室温度分布测量 QPP 10-91 (VYR-34:2005, čl. 2.2)","categories":["pharma","metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"13adc3f9be8b1d1eec791067","lab_id":"69ad52a4de79e566650fd380","country":"CZ","accr_number":"1325","accr_body":"ČIA","row_label":"8","test_object":"Sterylizatory na gorące powietrze, urządzenia techniki cieplnej","test_object_en":"Hot air sterilizers, heat technology devices","test_object_zh":"热空气灭菌器、热工技术设备","test_object_cs":"Horkovzdušné sterilizátory, přístroje teplotní techniky","methodology":"Pomiar rozkładu temperatury w komorze z wsadem","methodology_en":"Measurement of temperature distribution in chamber with the load","methodology_zh":"装载腔室温度分布测量","methodology_cs":"Měření distribuce teploty v komoře se vsázkou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar rozkładu temperatury w komorze z wsadem","reference":"QPP 10-98 (VYR-34:2005, čl. 2.2)","norm_bases":["QPP 10-98","VYR-34:2005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sterylizatory na gorące powietrze, urządzenia techniki cieplnej Pomiar rozkładu temperatury w komorze z wsadem Horkovzdušné sterilizátory, přístroje teplotní techniky Měření distribuce teploty v komoře se vsázkou QPP 10-98 (VYR-34:2005, čl. 2.2) Sterylizatory na gorace powietrze, urzadzenia techniki cieplnej Pomiar rozkladu temperatury w komorze z wsadem Horkovzdusne sterilizatory, pristroje teplotni techniky Mereni distribuce teploty v komore se vsazkou QPP 10-98 (VYR-34:2005, cl. 2.2)","search_en":"Hot air sterilizers, heat technology devices Measurement of temperature distribution in chamber with the load QPP 10-98 (VYR-34:2005, čl. 2.2)","search_zh":"热空气灭菌器、热工技术设备 装载腔室温度分布测量 QPP 10-98 (VYR-34:2005, čl. 2.2)","categories":["pharma","metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fc239a4333bffa83ecdaa354","lab_id":"69ad52a4de79e566650fd380","country":"CZ","accr_number":"1325","accr_body":"ČIA","row_label":"9","test_object":"Urządzenia techniki cieplnej (komory klimatyczne)","test_object_en":"Heat technology devices (climatic chambers)","test_object_zh":"热工技术设备（气候试验箱）","test_object_cs":"Přístroje teplotní techniky (klimatické komory)","methodology":"Pomiar temperatury i wilgotności","methodology_en":"Measurement of temperature and humidity","methodology_zh":"温度和湿度测量","methodology_cs":"Měření teploty a vlhkosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar temperatury i wilgotności","reference":"QPP 10-50 (ČSN EN IEC 60068-3-6 ed. 2; DIN 12 880)","norm_bases":["QPP 10-50","ČSN EN IEC 60068-3-6 ed. 2","DIN 12 880"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Urządzenia techniki cieplnej (komory klimatyczne) Pomiar temperatury i wilgotności Přístroje teplotní techniky (klimatické komory) Měření teploty a vlhkosti QPP 10-50 (ČSN EN IEC 60068-3-6 ed. 2; DIN 12 880) Urzadzenia techniki cieplnej (komory klimatyczne) Pomiar temperatury i wilgotnosci Pristroje teplotni techniky (klimaticke komory) Mereni teploty a vlhkosti QPP 10-50 (CSN EN IEC 60068-3-6 ed. 2; DIN 12 880)","search_en":"Heat technology devices (climatic chambers) Measurement of temperature and humidity QPP 10-50 (ČSN EN IEC 60068-3-6 ed. 2; DIN 12 880)","search_zh":"热工技术设备（气候试验箱） 温度和湿度测量 QPP 10-50 (ČSN EN IEC 60068-3-6 ed. 2; DIN 12 880)","categories":["pharma","metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}