{"lab":{"_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","categories":["materials"],"city":"Opava","imported_at":"2026-03-08T10:42:44.590Z","methods_count":95,"name":"TECHNICKÉ LABORATOŘE OPAVA, akciová společnost","parse_status":"parsed","parse_version":5,"pdf_files":["1322_569_2025_CS.pdf","1322_569_2025_EN.pdf"],"scope_summary":"Badania obudowy górniczej, maszyn i urządzeń, w tym górniczych, hydrauliki górniczej i ogólnej, lin, badania temperaturowe, klimatyczne, symulacji promieniowania słonecznego i odporności korozyjnej wyrobów, w zakresie określonym w załączniku do świadectwa.","search_text":"technické laboratoře opava, akciová společnost těšínská 2962/79b, předměstí, 746 01 opava other","status":"active","updated_at":"2026-03-08T14:52:10.639Z","valid_from":"","valid_until":"13-06-2029","website":"www.tlo.cz","parsed_at":"2026-09-28T12:00:00.000Z","location":{"type":"Point","coordinates":[17.9029,49.9389]},"email_confidence":"high","email_mx":true,"email_source":"https://www.tlo.cz/kontakt","map_coord":[49.941053,17.892526],"map_geo":"nominatim-city","certificate_date":"10.11.2025","certificate_no":"569/2025","certificate_replaces":"288/2024 z 13.06.2024","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania obudowy górniczej, maszyn i urządzeń, w tym górniczych, hydrauliki górniczej i ogólnej, lin, badania temperaturowe, klimatyczne, symulacji promieniowania słonecznego i odporności korozyjnej wyrobów, w zakresie określonym w załączniku do świadectwa.","en":"Testing of mine supports, machinery and equipment including mining, mining and general hydraulics, ropes and thermal, climatic, solar simulation and corrosion resistance tests of products to the extent as specified in the appendix to this Certificate.","zh":"矿用支护、机械和设备（含矿用）、矿用及通用液压、钢丝绳的检测，产品的温度、气候、太阳辐射模拟和耐腐蚀试验，范围见本证书附件。","cs":"Zkoušení důlní výztuže, strojů a zařízení včetně důlních, hydrauliky důlní i všeobecné, lan, zkoušky teplotní, klimatické, slunečních simulací a korozní odolnosti výrobků, vymezené přílohou tohoto osvědčení."}],"flexible_scope":true,"flexible_scope_url":"https://www.tlo.cz/sluzby/zkusebni-laborator/","has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze","lab_division_cs":"Zkušební laboratoř","lab_division_en":"Testing Laboratory","lab_division_zh":"检测实验室","lab_locations":[{"code":null,"name":"TECHNICKÉ LABORATOŘE OPAVA, akciová společnost","street":"Těšínská 2962/79b, Předměstí","postal_code":"746 01","city":"Opava","is_hq":true,"address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","site":"74601|těšínská2962/79bpředměstí"},{"code":null,"name":"oddział Opava","street":"Těšínská 2962/79b, Předměstí","postal_code":"746 01","city":"Opava","is_hq":false,"address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","site":"74601|těšínská2962/79bpředměstí"},{"code":null,"name":"oddział Čermná ve Slezsku","street":"Čermná ve Slezsku 100","postal_code":"749 01","city":"Čermná ve Slezsku","is_hq":false,"address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","site":"74901|čermnáveslezsku100"}],"lab_locations_en":[{"code":null,"name":"TECHNICKÉ LABORATOŘE OPAVA, akciová společnost","street":"Těšínská 2962/79b, Předměstí","postal_code":"746 01","city":"Opava","is_hq":true,"address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","site":"74601|těšínská2962/79bpředměstí"},{"code":null,"name":"Workplace Opava","street":"Těšínská 2962/79b, Předměstí","postal_code":"746 01","city":"Opava","is_hq":false,"address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","site":"74601|těšínská2962/79bpředměstí"},{"code":null,"name":"Workplace Čermná ve Slezsku","street":"Čermná ve Slezsku 100","postal_code":"749 01","city":"Čermná ve Slezsku","is_hq":false,"address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","site":"74901|čermnáveslezsku100"}],"lab_locations_zh":[{"code":null,"name":"TECHNICKÉ LABORATOŘE OPAVA, akciová společnost","street":"Těšínská 2962/79b, Předměstí","postal_code":"746 01","city":"Opava","is_hq":true,"address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","site":"74601|těšínská2962/79bpředměstí"},{"code":null,"name":"奥帕瓦工作场所","street":"Těšínská 2962/79b, Předměstí","postal_code":"746 01","city":"Opava","is_hq":false,"address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","site":"74601|těšínská2962/79bpředměstí"},{"code":null,"name":"Čermná ve Slezsku工作场所","street":"Čermná ve Slezsku 100","postal_code":"749 01","city":"Čermná ve Slezsku","is_hq":false,"address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","site":"74901|čermnáveslezsku100"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","scope_legend":[{"abbr":"PP","pl":"wewnętrzna procedura robocza Laboratorium Badawczego","en":"Internal Working Procedure of the Testing Laboratory","zh":"检测实验室内部工作程序","cs":"interní pracovní postup Zkušební laboratoře"},{"abbr":"NV","pl":"rozporządzenie rządu","en":"Government Regulation","zh":"政府条例","cs":"nařízení vlády"},{"abbr":"PR","pl":"procedura badawcza koncernu BMW","en":"BMW Group test procedure","zh":"宝马集团测试程序","cs":"zkušební postup koncernu BMW"},{"abbr":"PN","pl":"Polska Norma","en":"Polish standard","zh":"波兰标准","cs":"polská norma"},{"abbr":"DIN","pl":"norma niemiecka","en":"German standard","zh":"德国标准","cs":"německá norma"},{"abbr":"UNE","pl":"norma hiszpańska","en":"Spanish standard","zh":"西班牙标准","cs":"španělská norma"},{"abbr":"PV","pl":"procedura badawcza koncernu Volkswagen","en":"Volkswagen Group test procedure","zh":"大众集团测试程序","cs":"zkušební postup koncernu VolksWagen"},{"abbr":"ASTM","pl":"Amerykańskie Stowarzyszenie Badań i Materiałów","en":"American Society for Testing and Materials","zh":"美国材料与试验协会","cs":"americká společnost pro zkoušení a materiály"},{"abbr":"LV","pl":"norma badań elektrycznych i elektronicznych podzespołów pojazdów silnikowych","en":"Standard for testing electrical and electronic components in motor vehicles","zh":"机动车电气和电子部件测试标准","cs":"norma pro zkoušky elektrických a elektronických součásti v motorových vozidlech"},{"abbr":"GMW","pl":"procedura badawcza koncernu GM (General Motors Worldwide Engineering Standards)","en":"General‐Motors Worldwide Engineering Standards","zh":"通用汽车全球工程标准","cs":"zkušební postup koncernu GM (General-Motors Worldwide Engineering standards)"},{"abbr":"CONSOL","pl":"wymagania badawcze i inspekcyjne dla obudów zmechanizowanych opracowane przez CONSOL Inc. Maintenance Engineering Department","en":"Test and Inspection Requirements for Mechanized Reinforcements prepared by CONSOL Inc. Maintenance Engineering Department","zh":"CONSOL公司维护工程部制定的液压支架检测和检查要求","cs":"zkušební a inspekční požadavky na mechanizované výztuže zpracované fy CONSOL Inc. Maintenance Engineering Department"},{"abbr":"Qualicoat","pl":"norma badań do certyfikacji Qualicoat","en":"Qualicoat standard for Qualicoat certification testing","zh":"Qualicoat认证测试标准","cs":"norma pro zkoušky k certifikaci od firmy Qualicoat"},{"abbr":"GOST","pl":"norma rosyjska","en":"Russian standard","zh":"俄罗斯标准","cs":"ruská norma"},{"abbr":"VDA","pl":"niemiecka norma branżowa przemysłu motoryzacyjnego","en":"German Automotive Industry Technical Standard","zh":"德国汽车工业技术标准","cs":"německá oborová norma automobilového průmyslu"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"5294b44da50b4eb3bc4d8b21b8ac98b15add7ab36b7300fd8c4c3b7f787438bf","source_pdf_url":"https://www.cai.cz/OA/pdf/569_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/569_2025_EN.pdf"},"methods":[{"_id":"4026857731e024eb12dd48e2","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"1","test_object":"Indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze, obudowa zmechanizowana – stojaki hydrauliczne i siłowniki","test_object_en":"Individual reinforcement – hydraulic mine legs, powered supports – hydraulic legs and rams","test_object_zh":"单体采面支护–矿用液压支柱，液压支架–液压立柱和千斤顶","test_object_cs":"Individuální porubní výztuž – důlní stojky hydraulické, mechanizovaná výztuž – hydraulické stojky a válce","methodology":"Badanie szczelności","methodology_en":"Hydraulic test","methodology_zh":"密封性试验","methodology_cs":"Zkouška těsnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie szczelności","reference":"ČSN 44 4440, čl. 36; ČSN EN 1804-2, příl. A.1.1, A.1.2.4; EN 1804-2, příl. A.1.1, A.1.2.4","norm_bases":["ČSN 44 4440, čl. 36","ČSN EN 1804-2, příl. A.1.1, A.1.2.4","EN 1804-2, příl. A.1.1, A.1.2.4"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze, obudowa zmechanizowana – stojaki hydrauliczne i siłowniki Badanie szczelności Individuální porubní výztuž – důlní stojky hydraulické, mechanizovaná výztuž – hydraulické stojky a válce Zkouška těsnosti ČSN 44 4440, čl. 36; ČSN EN 1804-2, příl. A.1.1, A.1.2.4; EN 1804-2, příl. A.1.1, A.1.2.4 Indywidualna obudowa scianowa – hydrauliczne stojaki gornicze, obudowa zmechanizowana – stojaki hydrauliczne i silowniki Badanie szczelnosci Individualni porubni vyztuz – dulni stojky hydraulicke, mechanizovana vyztuz – hydraulicke stojky a valce Zkouska tesnosti CSN 44 4440, cl. 36; CSN EN 1804-2, pril. A.1.1, A.1.2.4; EN 1804-2, pril. A.1.1, A.1.2.4","search_en":"Individual reinforcement – hydraulic mine legs, powered supports – hydraulic legs and rams Hydraulic test ČSN 44 4440, čl. 36; ČSN EN 1804-2, příl. A.1.1, A.1.2.4; EN 1804-2, příl. A.1.1, A.1.2.4","search_zh":"单体采面支护–矿用液压支柱，液压支架–液压立柱和千斤顶 密封性试验 ČSN 44 4440, čl. 36; ČSN EN 1804-2, příl. A.1.1, A.1.2.4; EN 1804-2, příl. A.1.1, A.1.2.4","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"68863ef99001237b80c309c6","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"2","test_object":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory, hydrauliczne układy sterowania – zawory, mechanizmy hydrostatyczne","test_object_en":"Powered supports – hydraulic control systems – valves, hydraulic control systems – valves, hydrostatic mechanisms","test_object_zh":"液压支架–液压控制系统–阀门，液压控制系统–阀门，静液压机构","test_object_cs":"Mechanizovaná výztuž – hydraulické ovládací systémy – ventily, hydraulické ovládací systémy – ventily, hydrostatické mechanismy","methodology":"Badanie szczelności","methodology_en":"Hydraulic test","methodology_zh":"密封性试验","methodology_cs":"Zkouška těsnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie szczelności","reference":"ČSN EN 1804-3, příl. A1.1, A.1.3, A.1.3.1, A.1.3.2, A.1.4, A.1.4.1, A.1.4.2, A.1.5, A.1.5.1, A1.5.2; EN 1804-3, příl. A1.1, A.1.3, A.1.3.1, A.1.3.2, A.1.4, A.1.4.1, A.1.4.2, A.1.5, A.1.5.1, A1.5.2; ČSN 44 4450, příl. A.3.1, A.3.2, A.3.2.1, A.3.2.2; ČSN 11 9008, čl. 4.5; ČSN 44 4440, čl. 31","norm_bases":["ČSN EN 1804-3, příl. A1.1, A.1.3, A.1.3.1, A.1.3.2, A.1.4, A.1.4.1, A.1.4.2, A.1.5, A.1.5.1, A1.5.2","EN 1804-3, příl. A1.1, A.1.3, A.1.3.1, A.1.3.2, A.1.4, A.1.4.1, A.1.4.2, A.1.5, A.1.5.1, A1.5.2","ČSN 44 4450, příl. A.3.1, A.3.2, A.3.2.1, A.3.2.2","ČSN 11 9008, čl. 4.5","ČSN 44 4440, čl. 31"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory, hydrauliczne układy sterowania – zawory, mechanizmy hydrostatyczne Badanie szczelności Mechanizovaná výztuž – hydraulické ovládací systémy – ventily, hydraulické ovládací systémy – ventily, hydrostatické mechanismy Zkouška těsnosti ČSN EN 1804-3, příl. A1.1, A.1.3, A.1.3.1, A.1.3.2, A.1.4, A.1.4.1, A.1.4.2, A.1.5, A.1.5.1, A1.5.2; EN 1804-3, příl. A1.1, A.1.3, A.1.3.1, A.1.3.2, A.1.4, A.1.4.1, A.1.4.2, A.1.5, A.1.5.1, A1.5.2; ČSN 44 4450, příl. A.3.1, A.3.2, A.3.2.1, A.3.2.2; ČSN 11 9008, čl. 4.5; ČSN 44 4440, čl. 31 Obudowa zmechanizowana – hydrauliczne uklady sterowania – zawory, hydrauliczne uklady sterowania – zawory, mechanizmy hydrostatyczne Badanie szczelnosci Mechanizovana vyztuz – hydraulicke ovladaci systemy – ventily, hydraulicke ovladaci systemy – ventily, hydrostaticke mechanismy Zkouska tesnosti CSN EN 1804-3, pril. A1.1, A.1.3, A.1.3.1, A.1.3.2, A.1.4, A.1.4.1, A.1.4.2, A.1.5, A.1.5.1, A1.5.2; EN 1804-3, pril. A1.1, A.1.3, A.1.3.1, A.1.3.2, A.1.4, A.1.4.1, A.1.4.2, A.1.5, A.1.5.1, A1.5.2; CSN 44 4450, pril. A.3.1, A.3.2, A.3.2.1, A.3.2.2; CSN 11 9008, cl. 4.5; CSN 44 4440, cl. 31","search_en":"Powered supports – hydraulic control systems – valves, hydraulic control systems – valves, hydrostatic mechanisms Hydraulic test ČSN EN 1804-3, příl. A1.1, A.1.3, A.1.3.1, A.1.3.2, A.1.4, A.1.4.1, A.1.4.2, A.1.5, A.1.5.1, A1.5.2; EN 1804-3, příl. A1.1, A.1.3, A.1.3.1, A.1.3.2, A.1.4, A.1.4.1, A.1.4.2, A.1.5, A.1.5.1, A1.5.2; ČSN 44 4450, příl. A.3.1, A.3.2, A.3.2.1, A.3.2.2; ČSN 11 9008, čl. 4.5; ČSN 44 4440, čl. 31","search_zh":"液压支架–液压控制系统–阀门，液压控制系统–阀门，静液压机构 密封性试验 ČSN EN 1804-3, příl. A1.1, A.1.3, A.1.3.1, A.1.3.2, A.1.4, A.1.4.1, A.1.4.2, A.1.5, A.1.5.1, A1.5.2; EN 1804-3, příl. A1.1, A.1.3, A.1.3.1, A.1.3.2, A.1.4, A.1.4.1, A.1.4.2, A.1.5, A.1.5.1, A1.5.2; ČSN 44 4450, příl. A.3.1, A.3.2, A.3.2.1, A.3.2.2; ČSN 11 9008, čl. 4.5; ČSN 44 4440, čl. 31","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"763887c7de32bdee8c4cc371","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"3","test_object":"Indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze","test_object_en":"Individual face support – hydraulic pit props","test_object_zh":"单体采面支护–矿用液压支柱","test_object_cs":"Individuální porubní výztuž – důlní stojky hydraulické","methodology":"Próba napełniania","methodology_en":"Filling test","methodology_zh":"充液试验","methodology_cs":"Zkouška plnění","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba napełniania","reference":"ČSN 44 4440, čl. 34","norm_bases":["ČSN 44 4440, čl. 34"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze Próba napełniania Individuální porubní výztuž – důlní stojky hydraulické Zkouška plnění ČSN 44 4440, čl. 34 Indywidualna obudowa scianowa – hydrauliczne stojaki gornicze Proba napelniania Individualni porubni vyztuz – dulni stojky hydraulicke Zkouska plneni CSN 44 4440, cl. 34","search_en":"Individual face support – hydraulic pit props Filling test ČSN 44 4440, čl. 34","search_zh":"单体采面支护–矿用液压支柱 充液试验 ČSN 44 4440, čl. 34","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"374d80b334453f6053990b86","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"4","test_object":"Indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze","test_object_en":"Individual face support – hydraulic pit props","test_object_zh":"单体采面支护–矿用液压支柱","test_object_cs":"Individuální porubní výztuž – důlní stojky hydraulické","methodology":"Próba wsuwania rdzennika","methodology_en":"Inner column retraction test","methodology_zh":"内柱回缩试验","methodology_cs":"Zkouška zasouvání vnitřního sloupu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba wsuwania rdzennika","reference":"ČSN 44 4440, čl. 35","norm_bases":["ČSN 44 4440, čl. 35"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze Próba wsuwania rdzennika Individuální porubní výztuž – důlní stojky hydraulické Zkouška zasouvání vnitřního sloupu ČSN 44 4440, čl. 35 Indywidualna obudowa scianowa – hydrauliczne stojaki gornicze Proba wsuwania rdzennika Individualni porubni vyztuz – dulni stojky hydraulicke Zkouska zasouvani vnitrniho sloupu CSN 44 4440, cl. 35","search_en":"Individual face support – hydraulic pit props Inner column retraction test ČSN 44 4440, čl. 35","search_zh":"单体采面支护–矿用液压支柱 内柱回缩试验 ČSN 44 4440, čl. 35","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8541424ebdd59cd2c5d8e5be","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"5","test_object":"Indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze","test_object_en":"Individual face support – hydraulic pit props","test_object_zh":"单体采面支护–矿用液压支柱","test_object_cs":"Individuální porubní výztuž – důlní stojky hydraulické","methodology":"Próba wyznaczenia charakterystyki","methodology_en":"Test to determine characteristics","methodology_zh":"特性测定试验","methodology_cs":"Zkouška na zjištění charakteristiky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba wyznaczenia charakterystyki","reference":"ČSN 44 4440, čl. 37","norm_bases":["ČSN 44 4440, čl. 37"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze Próba wyznaczenia charakterystyki Individuální porubní výztuž – důlní stojky hydraulické Zkouška na zjištění charakteristiky ČSN 44 4440, čl. 37 Indywidualna obudowa scianowa – hydrauliczne stojaki gornicze Proba wyznaczenia charakterystyki Individualni porubni vyztuz – dulni stojky hydraulicke Zkouska na zjisteni charakteristiky CSN 44 4440, cl. 37","search_en":"Individual face support – hydraulic pit props Test to determine characteristics ČSN 44 4440, čl. 37","search_zh":"单体采面支护–矿用液压支柱 特性测定试验 ČSN 44 4440, čl. 37","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6061fe75882fe92a82a71b8a","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"6","test_object":"Indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze","test_object_en":"Individual face support – hydraulic pit props","test_object_zh":"单体采面支护–矿用液压支柱","test_object_cs":"Individuální porubní výztuž – důlní stojky hydraulické","methodology":"Próba przy obciążeniu osiowym","methodology_en":"Axial load test","methodology_zh":"轴向载荷试验","methodology_cs":"Zkouška při osovém zatížení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba przy obciążeniu osiowym","reference":"ČSN 44 4440, čl. 38","norm_bases":["ČSN 44 4440, čl. 38"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze Próba przy obciążeniu osiowym Individuální porubní výztuž – důlní stojky hydraulické Zkouška při osovém zatížení ČSN 44 4440, čl. 38 Indywidualna obudowa scianowa – hydrauliczne stojaki gornicze Proba przy obciazeniu osiowym Individualni porubni vyztuz – dulni stojky hydraulicke Zkouska pri osovem zatizeni CSN 44 4440, cl. 38","search_en":"Individual face support – hydraulic pit props Axial load test ČSN 44 4440, čl. 38","search_zh":"单体采面支护–矿用液压支柱 轴向载荷试验 ČSN 44 4440, čl. 38","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4498ae3a6d8cbecfa28d3631","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"7","test_object":"Indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze","test_object_en":"Individual face support – hydraulic pit props","test_object_zh":"单体采面支护–矿用液压支柱","test_object_cs":"Individuální porubní výztuž – důlní stojky hydraulické","methodology":"Próba przy obciążeniu mimośrodowym","methodology_en":"Extra-axial load test","methodology_zh":"偏心载荷试验","methodology_cs":"Zkouška při mimoosovém zatížení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba przy obciążeniu mimośrodowym","reference":"ČSN 44 4440, čl. 39","norm_bases":["ČSN 44 4440, čl. 39"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze Próba przy obciążeniu mimośrodowym Individuální porubní výztuž – důlní stojky hydraulické Zkouška při mimoosovém zatížení ČSN 44 4440, čl. 39 Indywidualna obudowa scianowa – hydrauliczne stojaki gornicze Proba przy obciazeniu mimosrodowym Individualni porubni vyztuz – dulni stojky hydraulicke Zkouska pri mimoosovem zatizeni CSN 44 4440, cl. 39","search_en":"Individual face support – hydraulic pit props Extra-axial load test ČSN 44 4440, čl. 39","search_zh":"单体采面支护–矿用液压支柱 偏心载荷试验 ČSN 44 4440, čl. 39","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"716d36a4f12e4675e8d18b90","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"8","test_object":"Obudowa zmechanizowana – sekcja obudowy, jezdne maszyny robocze, maszyny i urządzenia stacjonarne","test_object_en":"Roof support - support section, mobile working machines, stationary machines and equipment","test_object_zh":"液压支架–支架段、移动式工作机械、固定式机械和设备","test_object_cs":"Mechanizovaná výztuž – sekce výztuže, pojízdné pracovní stroje, stacionární stroje a zařízení","methodology":"Wyznaczanie wymiarów przejścia","methodology_en":"Determination of pass-through dimensions","methodology_zh":"通道尺寸测定","methodology_cs":"Stanovení rozměrů průchodu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie wymiarów przejścia","reference":"ČSN EN 1804-1, čl. 4.1.2; EN 1804-1, čl. 4.1.2; ČSN 44 4450, čl. 5.1.2; PP - 42.03.06 (ČSN EN ISO 2867)","norm_bases":["ČSN EN 1804-1, čl. 4.1.2","EN 1804-1, čl. 4.1.2","ČSN 44 4450, čl. 5.1.2","PP - 42.03.06","ČSN EN ISO 2867"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – sekcja obudowy, jezdne maszyny robocze, maszyny i urządzenia stacjonarne Wyznaczanie wymiarów przejścia Mechanizovaná výztuž – sekce výztuže, pojízdné pracovní stroje, stacionární stroje a zařízení Stanovení rozměrů průchodu ČSN EN 1804-1, čl. 4.1.2; EN 1804-1, čl. 4.1.2; ČSN 44 4450, čl. 5.1.2; PP - 42.03.06 (ČSN EN ISO 2867) Obudowa zmechanizowana – sekcja obudowy, jezdne maszyny robocze, maszyny i urzadzenia stacjonarne Wyznaczanie wymiarow przejscia Mechanizovana vyztuz – sekce vyztuze, pojizdne pracovni stroje, stacionarni stroje a zarizeni Stanoveni rozmeru pruchodu CSN EN 1804-1, cl. 4.1.2; EN 1804-1, cl. 4.1.2; CSN 44 4450, cl. 5.1.2; PP - 42.03.06 (CSN EN ISO 2867)","search_en":"Roof support - support section, mobile working machines, stationary machines and equipment Determination of pass-through dimensions ČSN EN 1804-1, čl. 4.1.2; EN 1804-1, čl. 4.1.2; ČSN 44 4450, čl. 5.1.2; PP - 42.03.06 (ČSN EN ISO 2867)","search_zh":"液压支架–支架段、移动式工作机械、固定式机械和设备 通道尺寸测定 ČSN EN 1804-1, čl. 4.1.2; EN 1804-1, čl. 4.1.2; ČSN 44 4450, čl. 5.1.2; PP - 42.03.06 (ČSN EN ISO 2867)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dd28ead68e174f724326eded","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"9","test_object":"Obudowa zmechanizowana – sekcja obudowy","test_object_en":"Roof support – support section","test_object_zh":"液压支架–支架段","test_object_cs":"Mechanizovaná výztuž – sekce výztuže","methodology":"Badanie hydrauliki – badanie funkcjonalności eksploatacyjnej elementów hydrauliki","methodology_en":"Hydraulics test – test of operational functionality of hydraulic components","methodology_zh":"液压试验–液压部件运行功能试验","methodology_cs":"Zkouška hydrauliky – zkouška provozní funkčnosti součástí hydrauliky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie hydrauliki – badanie funkcjonalności eksploatacyjnej elementów hydrauliki","reference":"ČSN EN 1804-1, příl. A.6; EN 1804-1, příl. A.6","norm_bases":["ČSN EN 1804-1, příl. A.6","EN 1804-1, příl. A.6"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – sekcja obudowy Badanie hydrauliki – badanie funkcjonalności eksploatacyjnej elementów hydrauliki Mechanizovaná výztuž – sekce výztuže Zkouška hydrauliky – zkouška provozní funkčnosti součástí hydrauliky ČSN EN 1804-1, příl. A.6; EN 1804-1, příl. A.6 Obudowa zmechanizowana – sekcja obudowy Badanie hydrauliki – badanie funkcjonalnosci eksploatacyjnej elementow hydrauliki Mechanizovana vyztuz – sekce vyztuze Zkouska hydrauliky – zkouska provozni funkcnosti soucasti hydrauliky CSN EN 1804-1, pril. A.6; EN 1804-1, pril. A.6","search_en":"Roof support – support section Hydraulics test – test of operational functionality of hydraulic components ČSN EN 1804-1, příl. A.6; EN 1804-1, příl. A.6","search_zh":"液压支架–支架段 液压试验–液压部件运行功能试验 ČSN EN 1804-1, příl. A.6; EN 1804-1, příl. A.6","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"502097c47aed133a469923ba","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"10","test_object":"Stropnica wysuwna – sekcja obudowy zmechanizowanej","test_object_en":"Roof bar – roof support section","test_object_zh":"前探梁–液压支架段","test_object_cs":"Předstropnice – sekce mechanizované výztuže","methodology":"Cykliczne badania zmęczeniowe","methodology_en":"Cyclic fatigue test","methodology_zh":"循环疲劳试验","methodology_cs":"Cyklické únavové zkoušky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Cykliczne badania zmęczeniowe","reference":"ČSN EN 1804-1, příl. A.1.3.1, A.1.3.2, A.5; EN 1804-1, příl. A.1.3.1, A.1.3.2, A.5","norm_bases":["ČSN EN 1804-1, příl. A.1.3.1, A.1.3.2, A.5","EN 1804-1, příl. A.1.3.1, A.1.3.2, A.5"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stropnica wysuwna – sekcja obudowy zmechanizowanej Cykliczne badania zmęczeniowe Předstropnice – sekce mechanizované výztuže Cyklické únavové zkoušky ČSN EN 1804-1, příl. A.1.3.1, A.1.3.2, A.5; EN 1804-1, příl. A.1.3.1, A.1.3.2, A.5 Stropnica wysuwna – sekcja obudowy zmechanizowanej Cykliczne badania zmeczeniowe Predstropnice – sekce mechanizovane vyztuze Cyklicke unavove zkousky CSN EN 1804-1, pril. A.1.3.1, A.1.3.2, A.5; EN 1804-1, pril. A.1.3.1, A.1.3.2, A.5","search_en":"Roof bar – roof support section Cyclic fatigue test ČSN EN 1804-1, příl. A.1.3.1, A.1.3.2, A.5; EN 1804-1, příl. A.1.3.1, A.1.3.2, A.5","search_zh":"前探梁–液压支架段 循环疲劳试验 ČSN EN 1804-1, příl. A.1.3.1, A.1.3.2, A.5; EN 1804-1, příl. A.1.3.1, A.1.3.2, A.5","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"70087beef8f484cc10a51b3b","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"11","test_object":"Stropnica wysuwna – sekcja obudowy zmechanizowanej","test_object_en":"Roof bar – roof support section","test_object_zh":"前探梁–液压支架段","test_object_cs":"Předstropnice – sekce mechanizované výztuže","methodology":"Próba zginania","methodology_en":"Bending test","methodology_zh":"弯曲试验","methodology_cs":"Zkouška na ohyb","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba zginania","reference":"ČSN EN 1804-1, příl. A.1.1, A.1.2.1, A5; EN 1804-1, příl. A.1.1, A.1.2.1, A5","norm_bases":["ČSN EN 1804-1, příl. A.1.1, A.1.2.1, A5","EN 1804-1, příl. A.1.1, A.1.2.1, A5"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stropnica wysuwna – sekcja obudowy zmechanizowanej Próba zginania Předstropnice – sekce mechanizované výztuže Zkouška na ohyb ČSN EN 1804-1, příl. A.1.1, A.1.2.1, A5; EN 1804-1, příl. A.1.1, A.1.2.1, A5 Stropnica wysuwna – sekcja obudowy zmechanizowanej Proba zginania Predstropnice – sekce mechanizovane vyztuze Zkouska na ohyb CSN EN 1804-1, pril. A.1.1, A.1.2.1, A5; EN 1804-1, pril. A.1.1, A.1.2.1, A5","search_en":"Roof bar – roof support section Bending test ČSN EN 1804-1, příl. A.1.1, A.1.2.1, A5; EN 1804-1, příl. A.1.1, A.1.2.1, A5","search_zh":"前探梁–液压支架段 弯曲试验 ČSN EN 1804-1, příl. A.1.1, A.1.2.1, A5; EN 1804-1, příl. A.1.1, A.1.2.1, A5","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c469c8e59162cbf49bca2c25","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"12","test_object":"Obudowa zmechanizowana – sekcja obudowy","test_object_en":"Roof support – support section","test_object_zh":"液压支架–支架段","test_object_cs":"Mechanizovaná výztuž – sekce výztuže","methodology":"Próba zginania","methodology_en":"Bending test","methodology_zh":"弯曲试验","methodology_cs":"Zkouška na ohyb","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba zginania","reference":"ČSN EN 1804-1, příl. A.1.1, A.1.2.1, A.1.2.2; EN 1804-1, příl. A.1.1, A.1.2.1, A.1.2.2; ČSN 44 4450, příl. A.1.1, A.1.2.1","norm_bases":["ČSN EN 1804-1, příl. A.1.1, A.1.2.1, A.1.2.2","EN 1804-1, příl. A.1.1, A.1.2.1, A.1.2.2","ČSN 44 4450, příl. A.1.1, A.1.2.1"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – sekcja obudowy Próba zginania Mechanizovaná výztuž – sekce výztuže Zkouška na ohyb ČSN EN 1804-1, příl. A.1.1, A.1.2.1, A.1.2.2; EN 1804-1, příl. A.1.1, A.1.2.1, A.1.2.2; ČSN 44 4450, příl. A.1.1, A.1.2.1 Obudowa zmechanizowana – sekcja obudowy Proba zginania Mechanizovana vyztuz – sekce vyztuze Zkouska na ohyb CSN EN 1804-1, pril. A.1.1, A.1.2.1, A.1.2.2; EN 1804-1, pril. A.1.1, A.1.2.1, A.1.2.2; CSN 44 4450, pril. A.1.1, A.1.2.1","search_en":"Roof support – support section Bending test ČSN EN 1804-1, příl. A.1.1, A.1.2.1, A.1.2.2; EN 1804-1, příl. A.1.1, A.1.2.1, A.1.2.2; ČSN 44 4450, příl. A.1.1, A.1.2.1","search_zh":"液压支架–支架段 弯曲试验 ČSN EN 1804-1, příl. A.1.1, A.1.2.1, A.1.2.2; EN 1804-1, příl. A.1.1, A.1.2.1, A.1.2.2; ČSN 44 4450, příl. A.1.1, A.1.2.1","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1b60602434ca85ba8f1ba8ed","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"13","test_object":"Obudowa zmechanizowana – sekcja obudowy","test_object_en":"Roof support – support section","test_object_zh":"液压支架–支架段","test_object_cs":"Mechanizovaná výztuž – sekce výztuže","methodology":"Próba przy obciążeniu poziomym obudowy kasztowej","methodology_en":"Testing at horizontal load of trestle supports","methodology_zh":"垛式支架水平载荷试验","methodology_cs":"Zkouška při horizontálním zatížení hráňových výztuží","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba przy obciążeniu poziomym obudowy kasztowej","reference":"ČSN EN 1804-1, příl. A.1.1, A.1.2.5; EN 1804-1, příl. A.1.1, A.1.2.5","norm_bases":["ČSN EN 1804-1, příl. A.1.1, A.1.2.5","EN 1804-1, příl. A.1.1, A.1.2.5"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – sekcja obudowy Próba przy obciążeniu poziomym obudowy kasztowej Mechanizovaná výztuž – sekce výztuže Zkouška při horizontálním zatížení hráňových výztuží ČSN EN 1804-1, příl. A.1.1, A.1.2.5; EN 1804-1, příl. A.1.1, A.1.2.5 Obudowa zmechanizowana – sekcja obudowy Proba przy obciazeniu poziomym obudowy kasztowej Mechanizovana vyztuz – sekce vyztuze Zkouska pri horizontalnim zatizeni hranovych vyztuzi CSN EN 1804-1, pril. A.1.1, A.1.2.5; EN 1804-1, pril. A.1.1, A.1.2.5","search_en":"Roof support – support section Testing at horizontal load of trestle supports ČSN EN 1804-1, příl. A.1.1, A.1.2.5; EN 1804-1, příl. A.1.1, A.1.2.5","search_zh":"液压支架–支架段 垛式支架水平载荷试验 ČSN EN 1804-1, příl. A.1.1, A.1.2.5; EN 1804-1, příl. A.1.1, A.1.2.5","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7042a006259dd7b3d9bcf6ca","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"14","test_object":"Obudowa zmechanizowana – sekcja obudowy","test_object_en":"Roof support – support section","test_object_zh":"液压支架–支架段","test_object_cs":"Mechanizovaná výztuž – sekce výztuže","methodology":"Cykliczne badania zmęczeniowe","methodology_en":"Cyclic fatigue tests","methodology_zh":"循环疲劳试验","methodology_cs":"Cyklické únavové zkoušky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Cykliczne badania zmęczeniowe","reference":"ČSN EN 1804-1, příl. A.1.1, A.1.3; EN 1804-1, příl. A.1.1, A.1.3","norm_bases":["ČSN EN 1804-1, příl. A.1.1, A.1.3","EN 1804-1, příl. A.1.1, A.1.3"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – sekcja obudowy Cykliczne badania zmęczeniowe Mechanizovaná výztuž – sekce výztuže Cyklické únavové zkoušky ČSN EN 1804-1, příl. A.1.1, A.1.3; EN 1804-1, příl. A.1.1, A.1.3 Obudowa zmechanizowana – sekcja obudowy Cykliczne badania zmeczeniowe Mechanizovana vyztuz – sekce vyztuze Cyklicke unavove zkousky CSN EN 1804-1, pril. A.1.1, A.1.3; EN 1804-1, pril. A.1.1, A.1.3","search_en":"Roof support – support section Cyclic fatigue tests ČSN EN 1804-1, příl. A.1.1, A.1.3; EN 1804-1, příl. A.1.1, A.1.3","search_zh":"液压支架–支架段 循环疲劳试验 ČSN EN 1804-1, příl. A.1.1, A.1.3; EN 1804-1, příl. A.1.1, A.1.3","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dcc3e5bf920c728d839e855c","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"15","test_object":"Obudowa zmechanizowana – sekcja obudowy","test_object_en":"Roof support – support section","test_object_zh":"液压支架–支架段","test_object_cs":"Mechanizovaná výztuž – sekce výztuže","methodology":"Badanie punktów podnoszenia i ciągnięcia","methodology_en":"Lifting and pulling points test","methodology_zh":"起吊点和牵引点试验","methodology_cs":"Zkouška zvedacích a tažných bodů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie punktów podnoszenia i ciągnięcia","reference":"ČSN EN 1804-1, příl. A.4; EN 1804-1, příl. A.4","norm_bases":["ČSN EN 1804-1, příl. A.4","EN 1804-1, příl. A.4"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – sekcja obudowy Badanie punktów podnoszenia i ciągnięcia Mechanizovaná výztuž – sekce výztuže Zkouška zvedacích a tažných bodů ČSN EN 1804-1, příl. A.4; EN 1804-1, příl. A.4 Obudowa zmechanizowana – sekcja obudowy Badanie punktow podnoszenia i ciagniecia Mechanizovana vyztuz – sekce vyztuze Zkouska zvedacich a taznych bodu CSN EN 1804-1, pril. A.4; EN 1804-1, pril. A.4","search_en":"Roof support – support section Lifting and pulling points test ČSN EN 1804-1, příl. A.4; EN 1804-1, příl. A.4","search_zh":"液压支架–支架段 起吊点和牵引点试验 ČSN EN 1804-1, příl. A.4; EN 1804-1, příl. A.4","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9e6b9bac966b59beb03f390a","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"16","test_object":"Obudowa zmechanizowana – sekcja obudowy","test_object_en":"Roof support – support section","test_object_zh":"液压支架–支架段","test_object_cs":"Mechanizovaná výztuž – sekce výztuže","methodology":"Badanie odporności na przewrócenie","methodology_en":"Turnover resistance test","methodology_zh":"抗倾覆试验","methodology_cs":"Zkouška odolnosti proti převrácení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na przewrócenie","reference":"ČSN EN 1804-1, čl. 4.2; EN 1804-1, čl. 4.2","norm_bases":["ČSN EN 1804-1, čl. 4.2","EN 1804-1, čl. 4.2"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – sekcja obudowy Badanie odporności na przewrócenie Mechanizovaná výztuž – sekce výztuže Zkouška odolnosti proti převrácení ČSN EN 1804-1, čl. 4.2; EN 1804-1, čl. 4.2 Obudowa zmechanizowana – sekcja obudowy Badanie odpornosci na przewrocenie Mechanizovana vyztuz – sekce vyztuze Zkouska odolnosti proti prevraceni CSN EN 1804-1, cl. 4.2; EN 1804-1, cl. 4.2","search_en":"Roof support – support section Turnover resistance test ČSN EN 1804-1, čl. 4.2; EN 1804-1, čl. 4.2","search_zh":"液压支架–支架段 抗倾覆试验 ČSN EN 1804-1, čl. 4.2; EN 1804-1, čl. 4.2","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d767aab4eefa4fee8a265e09","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"17","test_object":"Obudowa zmechanizowana – sekcja obudowy","test_object_en":"Roof support – support section","test_object_zh":"液压支架–支架段","test_object_cs":"Mechanizovaná výztuž – sekce výztuže","methodology":"Próba rozciągania i ściskania miejsc (punktów) przenoszących siły od stojaków i siłowników – uchwyty","methodology_en":"Tensile and pressure test of pit prop and valve power transmission points - fittings","methodology_zh":"立柱和千斤顶传力部位（点）拉压试验–连接件","methodology_cs":"Zkouška na tah a tlak pro místa (body) přenášející síly od stojek a válců – úchyty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba rozciągania i ściskania miejsc (punktów) przenoszących siły od stojaków i siłowników – uchwyty","reference":"ČSN EN 1804-1, příl.A.1.2.3; EN 1804-1, příl. A.1.2.3; ČSN 44 4450, příl. A.1.2.2","norm_bases":["ČSN EN 1804-1, příl.A.1.2.3","EN 1804-1, příl. A.1.2.3","ČSN 44 4450, příl. A.1.2.2"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – sekcja obudowy Próba rozciągania i ściskania miejsc (punktów) przenoszących siły od stojaków i siłowników – uchwyty Mechanizovaná výztuž – sekce výztuže Zkouška na tah a tlak pro místa (body) přenášející síly od stojek a válců – úchyty ČSN EN 1804-1, příl.A.1.2.3; EN 1804-1, příl. A.1.2.3; ČSN 44 4450, příl. A.1.2.2 Obudowa zmechanizowana – sekcja obudowy Proba rozciagania i sciskania miejsc (punktow) przenoszacych sily od stojakow i silownikow – uchwyty Mechanizovana vyztuz – sekce vyztuze Zkouska na tah a tlak pro mista (body) prenasejici sily od stojek a valcu – uchyty CSN EN 1804-1, pril.A.1.2.3; EN 1804-1, pril. A.1.2.3; CSN 44 4450, pril. A.1.2.2","search_en":"Roof support – support section Tensile and pressure test of pit prop and valve power transmission points - fittings ČSN EN 1804-1, příl.A.1.2.3; EN 1804-1, příl. A.1.2.3; ČSN 44 4450, příl. A.1.2.2","search_zh":"液压支架–支架段 立柱和千斤顶传力部位（点）拉压试验–连接件 ČSN EN 1804-1, příl.A.1.2.3; EN 1804-1, příl. A.1.2.3; ČSN 44 4450, příl. A.1.2.2","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1477d3ae3b63c3be9a699168","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"18","test_object":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki","test_object_en":"Roof support - hydraulic pit props and rams","test_object_zh":"液压支架–液压立柱和千斤顶","test_object_cs":"Mechanizovaná výztuž – hydraulické stojky a válce","methodology":"Badanie ograniczenia wysuwu","methodology_en":"Extension limit test","methodology_zh":"伸出限位试验","methodology_cs":"Zkouška omezení vysunutí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie ograniczenia wysuwu","reference":"ČSN EN 1804-2, příl. A.1.1, A.1.2.1; EN 1804-2, příl. A.1.1, A.1.2.1; ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.1","norm_bases":["ČSN EN 1804-2, příl. A.1.1, A.1.2.1","EN 1804-2, příl. A.1.1, A.1.2.1","ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.1"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki Badanie ograniczenia wysuwu Mechanizovaná výztuž – hydraulické stojky a válce Zkouška omezení vysunutí ČSN EN 1804-2, příl. A.1.1, A.1.2.1; EN 1804-2, příl. A.1.1, A.1.2.1; ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.1 Obudowa zmechanizowana – stojaki hydrauliczne i silowniki Badanie ograniczenia wysuwu Mechanizovana vyztuz – hydraulicke stojky a valce Zkouska omezeni vysunuti CSN EN 1804-2, pril. A.1.1, A.1.2.1; EN 1804-2, pril. A.1.1, A.1.2.1; CSN 44 4450, pril. A.2.1, A.2.1.1, A.2.2, A.2.2.1","search_en":"Roof support - hydraulic pit props and rams Extension limit test ČSN EN 1804-2, příl. A.1.1, A.1.2.1; EN 1804-2, příl. A.1.1, A.1.2.1; ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.1","search_zh":"液压支架–液压立柱和千斤顶 伸出限位试验 ČSN EN 1804-2, příl. A.1.1, A.1.2.1; EN 1804-2, příl. A.1.1, A.1.2.1; ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.1","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9340facde78f792e11d1041e","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"19","test_object":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki","test_object_en":"Roof support - hydraulic pit props and rams","test_object_zh":"液压支架–液压立柱和千斤顶","test_object_cs":"Mechanizovaná výztuž – hydraulické stojky a válce","methodology":"Próba podatności – pomiar prędkości poślizgu przy obciążeniu zewnętrznym","methodology_en":"Yielding test – measurement of slip rate under external load","methodology_zh":"让压试验–外部载荷下滑移速度测量","methodology_cs":"Zkouška poddajnosti – měření rychlosti prokluzu při externím zatížení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba podatności – pomiar prędkości poślizgu przy obciążeniu zewnętrznym","reference":"ČSN EN 1804-2, příl. A.1.1, A.1.2.2; EN 1804-2, příl. A.1.1, A.1.2.2; ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.3; ČSN EN 1804-1, příl. A.1.2.4; EN 1804-1, příl. A.1.2.4","norm_bases":["ČSN EN 1804-2, příl. A.1.1, A.1.2.2","EN 1804-2, příl. A.1.1, A.1.2.2","ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.3","ČSN EN 1804-1, příl. A.1.2.4","EN 1804-1, příl. A.1.2.4"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki Próba podatności – pomiar prędkości poślizgu przy obciążeniu zewnętrznym Mechanizovaná výztuž – hydraulické stojky a válce Zkouška poddajnosti – měření rychlosti prokluzu při externím zatížení ČSN EN 1804-2, příl. A.1.1, A.1.2.2; EN 1804-2, příl. A.1.1, A.1.2.2; ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.3; ČSN EN 1804-1, příl. A.1.2.4; EN 1804-1, příl. A.1.2.4 Obudowa zmechanizowana – stojaki hydrauliczne i silowniki Proba podatnosci – pomiar predkosci poslizgu przy obciazeniu zewnetrznym Mechanizovana vyztuz – hydraulicke stojky a valce Zkouska poddajnosti – mereni rychlosti prokluzu pri externim zatizeni CSN EN 1804-2, pril. A.1.1, A.1.2.2; EN 1804-2, pril. A.1.1, A.1.2.2; CSN 44 4450, pril. A.2.1, A.2.1.1, A.2.2, A.2.2.3; CSN EN 1804-1, pril. A.1.2.4; EN 1804-1, pril. A.1.2.4","search_en":"Roof support - hydraulic pit props and rams Yielding test – measurement of slip rate under external load ČSN EN 1804-2, příl. A.1.1, A.1.2.2; EN 1804-2, příl. A.1.1, A.1.2.2; ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.3; ČSN EN 1804-1, příl. A.1.2.4; EN 1804-1, příl. A.1.2.4","search_zh":"液压支架–液压立柱和千斤顶 让压试验–外部载荷下滑移速度测量 ČSN EN 1804-2, příl. A.1.1, A.1.2.2; EN 1804-2, příl. A.1.1, A.1.2.2; ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.3; ČSN EN 1804-1, příl. A.1.2.4; EN 1804-1, příl. A.1.2.4","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2c5f77fcada8334161cb1a67","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"20","test_object":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki","test_object_en":"Roof support - hydraulic pit props and rams","test_object_zh":"液压支架–液压立柱和千斤顶","test_object_cs":"Mechanizovaná výztuž – hydraulické stojky a válce","methodology":"Próba przeciążeniowa – przeciążenie statyczne","methodology_en":"Overload test – static overload","methodology_zh":"超载试验–静态超载","methodology_cs":"Zkouška přetížením – statické přetížení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba przeciążeniowa – przeciążenie statyczne","reference":"ČSN EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.1; EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.1; ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.2, A.2.2.2.1","norm_bases":["ČSN EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.1","EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.1","ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.2, A.2.2.2.1"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki Próba przeciążeniowa – przeciążenie statyczne Mechanizovaná výztuž – hydraulické stojky a válce Zkouška přetížením – statické přetížení ČSN EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.1; EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.1; ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.2, A.2.2.2.1 Obudowa zmechanizowana – stojaki hydrauliczne i silowniki Proba przeciazeniowa – przeciazenie statyczne Mechanizovana vyztuz – hydraulicke stojky a valce Zkouska pretizenim – staticke pretizeni CSN EN 1804-2, pril. A.1.1, A.1.2.3, A.1.2.3.1; EN 1804-2, pril. A.1.1, A.1.2.3, A.1.2.3.1; CSN 44 4450, pril. A.2.1, A.2.1.1, A.2.2, A.2.2.2, A.2.2.2.1","search_en":"Roof support - hydraulic pit props and rams Overload test – static overload ČSN EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.1; EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.1; ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.2, A.2.2.2.1","search_zh":"液压支架–液压立柱和千斤顶 超载试验–静态超载 ČSN EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.1; EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.1; ČSN 44 4450, příl. A.2.1, A.2.1.1, A.2.2, A.2.2.2, A.2.2.2.1","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"da73ae324ec725a9554813ce","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"21","test_object":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki","test_object_en":"Roof support - hydraulic pit props and rams","test_object_zh":"液压支架–液压立柱和千斤顶","test_object_cs":"Mechanizovaná výztuž – hydraulické stojky a válce","methodology":"Próba przeciążeniowa – przeciążenie dynamiczne","methodology_en":"Overload test – dynamic overload","methodology_zh":"超载试验–动态超载","methodology_cs":"Zkouška přetížením – dynamické přetížení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba przeciążeniowa – przeciążenie dynamiczne","reference":"ČSN EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.2; EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.2","norm_bases":["ČSN EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.2","EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.2"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki Próba przeciążeniowa – przeciążenie dynamiczne Mechanizovaná výztuž – hydraulické stojky a válce Zkouška přetížením – dynamické přetížení ČSN EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.2; EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.2 Obudowa zmechanizowana – stojaki hydrauliczne i silowniki Proba przeciazeniowa – przeciazenie dynamiczne Mechanizovana vyztuz – hydraulicke stojky a valce Zkouska pretizenim – dynamicke pretizeni CSN EN 1804-2, pril. A.1.1, A.1.2.3, A.1.2.3.2; EN 1804-2, pril. A.1.1, A.1.2.3, A.1.2.3.2","search_en":"Roof support - hydraulic pit props and rams Overload test – dynamic overload ČSN EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.2; EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.2","search_zh":"液压支架–液压立柱和千斤顶 超载试验–动态超载 ČSN EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.2; EN 1804-2, příl. A.1.1, A.1.2.3, A.1.2.3.2","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6ed9e963106f896d77e8fe0d","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"22","test_object":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki","test_object_en":"Roof support - hydraulic pit props and rams","test_object_zh":"液压支架–液压立柱和千斤顶","test_object_cs":"Mechanizovaná výztuž – hydraulické stojky a válce","methodology":"Próba siłą mimośrodową – próba zginania","methodology_en":"Eccentric force test – bending test","methodology_zh":"偏心力试验–弯曲试验","methodology_cs":"Zkouška excentrickou silou – zkouška ohybem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba siłą mimośrodową – próba zginania","reference":"ČSN EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.2; EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.2","norm_bases":["ČSN EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.2","EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.2"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki Próba siłą mimośrodową – próba zginania Mechanizovaná výztuž – hydraulické stojky a válce Zkouška excentrickou silou – zkouška ohybem ČSN EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.2; EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.2 Obudowa zmechanizowana – stojaki hydrauliczne i silowniki Proba sila mimosrodowa – proba zginania Mechanizovana vyztuz – hydraulicke stojky a valce Zkouska excentrickou silou – zkouska ohybem CSN EN 1804-2, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.2; EN 1804-2, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.2","search_en":"Roof support - hydraulic pit props and rams Eccentric force test – bending test ČSN EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.2; EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.2","search_zh":"液压支架–液压立柱和千斤顶 偏心力试验–弯曲试验 ČSN EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.2; EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.2","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cc25aa9551004510a29b86ab","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"23","test_object":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki","test_object_en":"Roof support - hydraulic pit props and rams","test_object_zh":"液压支架–液压立柱和千斤顶","test_object_cs":"Mechanizovaná výztuž – hydraulické stojky a válce","methodology":"Próba siłą mimośrodową – próba podatności","methodology_en":"Eccentric force test – yielding test","methodology_zh":"偏心力试验–让压试验","methodology_cs":"Zkouška excentrickou silou – zkouška poddajnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba siłą mimośrodową – próba podatności","reference":"ČSN EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3; EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3","norm_bases":["ČSN EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3","EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki Próba siłą mimośrodową – próba podatności Mechanizovaná výztuž – hydraulické stojky a válce Zkouška excentrickou silou – zkouška poddajnosti ČSN EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3; EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3 Obudowa zmechanizowana – stojaki hydrauliczne i silowniki Proba sila mimosrodowa – proba podatnosci Mechanizovana vyztuz – hydraulicke stojky a valce Zkouska excentrickou silou – zkouska poddajnosti CSN EN 1804-2, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.3; EN 1804-2, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.3","search_en":"Roof support - hydraulic pit props and rams Eccentric force test – yielding test ČSN EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3; EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3","search_zh":"液压支架–液压立柱和千斤顶 偏心力试验–让压试验 ČSN EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3; EN 1804-2, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9ef3704fd4e58dacb543ed32","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"24","test_object":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki","test_object_en":"Roof support - hydraulic pit props and rams","test_object_zh":"液压支架–液压立柱和千斤顶","test_object_cs":"Mechanizovaná výztuž – hydraulické stojky a válce","methodology":"Badanie trwałości","methodology_en":"Durability test","methodology_zh":"耐久性试验","methodology_cs":"Zkouška životnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie trwałości","reference":"ČSN EN 1804-2, příl. A.1.1, A.1.4; EN 1804-2, příl. A.1.1, A.1.4","norm_bases":["ČSN EN 1804-2, příl. A.1.1, A.1.4","EN 1804-2, příl. A.1.1, A.1.4"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki Badanie trwałości Mechanizovaná výztuž – hydraulické stojky a válce Zkouška životnosti ČSN EN 1804-2, příl. A.1.1, A.1.4; EN 1804-2, příl. A.1.1, A.1.4 Obudowa zmechanizowana – stojaki hydrauliczne i silowniki Badanie trwalosci Mechanizovana vyztuz – hydraulicke stojky a valce Zkouska zivotnosti CSN EN 1804-2, pril. A.1.1, A.1.4; EN 1804-2, pril. A.1.1, A.1.4","search_en":"Roof support - hydraulic pit props and rams Durability test ČSN EN 1804-2, příl. A.1.1, A.1.4; EN 1804-2, příl. A.1.1, A.1.4","search_zh":"液压支架–液压立柱和千斤顶 耐久性试验 ČSN EN 1804-2, příl. A.1.1, A.1.4; EN 1804-2, příl. A.1.1, A.1.4","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ca34ce1591ac0ca0ea7a8fc3","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"25","test_object":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki","test_object_en":"Roof support - hydraulic pit props and rams","test_object_zh":"液压支架–液压立柱和千斤顶","test_object_cs":"Mechanizovaná výztuž – hydraulické stojky a válce","methodology":"Badanie punktów podnoszenia siłą rozciągającą","methodology_en":"Tensile force test of lifting points","methodology_zh":"起吊点拉力试验","methodology_cs":"Zkouška zvedacích bodů tahovou silou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie punktów podnoszenia siłą rozciągającą","reference":"ČSN EN 1804-2, příl. A.1.5; EN 1804-2, příl. A.1.5","norm_bases":["ČSN EN 1804-2, příl. A.1.5","EN 1804-2, příl. A.1.5"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – stojaki hydrauliczne i siłowniki Badanie punktów podnoszenia siłą rozciągającą Mechanizovaná výztuž – hydraulické stojky a válce Zkouška zvedacích bodů tahovou silou ČSN EN 1804-2, příl. A.1.5; EN 1804-2, příl. A.1.5 Obudowa zmechanizowana – stojaki hydrauliczne i silowniki Badanie punktow podnoszenia sila rozciagajaca Mechanizovana vyztuz – hydraulicke stojky a valce Zkouska zvedacich bodu tahovou silou CSN EN 1804-2, pril. A.1.5; EN 1804-2, pril. A.1.5","search_en":"Roof support - hydraulic pit props and rams Tensile force test of lifting points ČSN EN 1804-2, příl. A.1.5; EN 1804-2, příl. A.1.5","search_zh":"液压支架–液压立柱和千斤顶 起吊点拉力试验 ČSN EN 1804-2, příl. A.1.5; EN 1804-2, příl. A.1.5","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3132b043fa956bf922250450","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"26","test_object":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory, indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze","test_object_en":"Powered supports – hydraulic control systems – valves, individual reinforcement – hydraulic mine legs","test_object_zh":"液压支架–液压控制系统–阀门，单体采面支护–矿用液压支柱","test_object_cs":"Mechanizovaná výztuž – hydraulické ovládací systémy – ventily, individuální porubní výztuž – důlní stojky hydraulické","methodology":"Próba ciśnieniowa","methodology_en":"Pressure test","methodology_zh":"压力试验","methodology_cs":"Tlaková zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba ciśnieniowa","reference":"ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3, A.1.3.4, A.1.4, A.1.4.1, A.1.4.3 A.1.5, A.1.5.1, A.1.5.3; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3, A.1.3.4, A.1.4, A.1.4.1, A.1.4.3 A.1.5, A.1.5.1, A.1.5.3; ČSN 44 4450, příl. A.3.1, A.3.2, A.3.2.1, A.3.2.3, A.3.2.5; ČSN 44 4440, čl. 32 a)","norm_bases":["ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3, A.1.3.4, A.1.4, A.1.4.1, A.1.4.3 A.1.5, A.1.5.1, A.1.5.3","EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3, A.1.3.4, A.1.4, A.1.4.1, A.1.4.3 A.1.5, A.1.5.1, A.1.5.3","ČSN 44 4450, příl. A.3.1, A.3.2, A.3.2.1, A.3.2.3, A.3.2.5","ČSN 44 4440, čl. 32 a)"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory, indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze Próba ciśnieniowa Mechanizovaná výztuž – hydraulické ovládací systémy – ventily, individuální porubní výztuž – důlní stojky hydraulické Tlaková zkouška ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3, A.1.3.4, A.1.4, A.1.4.1, A.1.4.3 A.1.5, A.1.5.1, A.1.5.3; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3, A.1.3.4, A.1.4, A.1.4.1, A.1.4.3 A.1.5, A.1.5.1, A.1.5.3; ČSN 44 4450, příl. A.3.1, A.3.2, A.3.2.1, A.3.2.3, A.3.2.5; ČSN 44 4440, čl. 32 a) Obudowa zmechanizowana – hydrauliczne uklady sterowania – zawory, indywidualna obudowa scianowa – hydrauliczne stojaki gornicze Proba cisnieniowa Mechanizovana vyztuz – hydraulicke ovladaci systemy – ventily, individualni porubni vyztuz – dulni stojky hydraulicke Tlakova zkouska CSN EN 1804-3, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.3, A.1.3.4, A.1.4, A.1.4.1, A.1.4.3 A.1.5, A.1.5.1, A.1.5.3; EN 1804-3, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.3, A.1.3.4, A.1.4, A.1.4.1, A.1.4.3 A.1.5, A.1.5.1, A.1.5.3; CSN 44 4450, pril. A.3.1, A.3.2, A.3.2.1, A.3.2.3, A.3.2.5; CSN 44 4440, cl. 32 a)","search_en":"Powered supports – hydraulic control systems – valves, individual reinforcement – hydraulic mine legs Pressure test ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3, A.1.3.4, A.1.4, A.1.4.1, A.1.4.3 A.1.5, A.1.5.1, A.1.5.3; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3, A.1.3.4, A.1.4, A.1.4.1, A.1.4.3 A.1.5, A.1.5.1, A.1.5.3; ČSN 44 4450, příl. A.3.1, A.3.2, A.3.2.1, A.3.2.3, A.3.2.5; ČSN 44 4440, čl. 32 a)","search_zh":"液压支架–液压控制系统–阀门，单体采面支护–矿用液压支柱 压力试验 ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3, A.1.3.4, A.1.4, A.1.4.1, A.1.4.3 A.1.5, A.1.5.1, A.1.5.3; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.3, A.1.3.4, A.1.4, A.1.4.1, A.1.4.3 A.1.5, A.1.5.1, A.1.5.3; ČSN 44 4450, příl. A.3.1, A.3.2, A.3.2.1, A.3.2.3, A.3.2.5; ČSN 44 4440, čl. 32 a)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f07db40ed5fcc4d0cbd6f1a4","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"27","test_object":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory typu A","test_object_en":"Roof support - Hydraulic control systems – Type A valves","test_object_zh":"液压支架–液压控制系统–A型阀","test_object_cs":"Mechanizovaná výztuž – hydraulické ovládací systémy – ventily typu A","methodology":"Próba hydraulicznym impulsem ciśnienia","methodology_en":"Hydraulic pressure pulse test","methodology_zh":"液压脉冲试验","methodology_cs":"Zkouška hydraulickým tlakovým impulzem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba hydraulicznym impulsem ciśnienia","reference":"ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.5; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.5","norm_bases":["ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.5","EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.5"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory typu A Próba hydraulicznym impulsem ciśnienia Mechanizovaná výztuž – hydraulické ovládací systémy – ventily typu A Zkouška hydraulickým tlakovým impulzem ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.5; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.5 Obudowa zmechanizowana – hydrauliczne uklady sterowania – zawory typu A Proba hydraulicznym impulsem cisnienia Mechanizovana vyztuz – hydraulicke ovladaci systemy – ventily typu A Zkouska hydraulickym tlakovym impulzem CSN EN 1804-3, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.5; EN 1804-3, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.5","search_en":"Roof support - Hydraulic control systems – Type A valves Hydraulic pressure pulse test ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.5; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.5","search_zh":"液压支架–液压控制系统–A型阀 液压脉冲试验 ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.5; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.5","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a15934604701420f9826ec21","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"28","test_object":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory typu A","test_object_en":"Roof support - Hydraulic control systems – Type A valves","test_object_zh":"液压支架–液压控制系统–A型阀","test_object_cs":"Mechanizovaná výztuž – hydraulické ovládací systémy – ventily typu A","methodology":"Próba udarowa","methodology_en":"Impact test","methodology_zh":"冲击试验","methodology_cs":"Nárazová zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba udarowa","reference":"ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.6; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.6","norm_bases":["ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.6","EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.6"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory typu A Próba udarowa Mechanizovaná výztuž – hydraulické ovládací systémy – ventily typu A Nárazová zkouška ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.6; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.6 Obudowa zmechanizowana – hydrauliczne uklady sterowania – zawory typu A Proba udarowa Mechanizovana vyztuz – hydraulicke ovladaci systemy – ventily typu A Narazova zkouska CSN EN 1804-3, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.6; EN 1804-3, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.6","search_en":"Roof support - Hydraulic control systems – Type A valves Impact test ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.6; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.6","search_zh":"液压支架–液压控制系统–A型阀 冲击试验 ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.6; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.6","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e11952a71b97788e4e731a0c","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"29","test_object":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory typu A, indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze – zawory","test_object_en":"Powered supports – hydraulic control systems – type A valves, individual reinforcement – hydraulic mine legs – valves","test_object_zh":"液压支架–液压控制系统–A型阀，单体采面支护–矿用液压支柱–阀门","test_object_cs":"Mechanizovaná výztuž – hydraulické ovládací systémy – ventily typu A, individuální porubní výztuž – důlní stojky hydraulické – ventily","methodology":"Badanie charakterystyki ciśnienie/przepływ","methodology_en":"Pressure/flow behaviour test","methodology_zh":"压力/流量特性试验","methodology_cs":"Zkouška chování tlak/průtok","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie charakterystyki ciśnienie/przepływ","reference":"ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.7; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.7; ČSN 44 4450, příl. A.3.2, A.3.2.1, A.3.2.4; ČSN 44 4440, čl. 32 b)","norm_bases":["ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.7","EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.7","ČSN 44 4450, příl. A.3.2, A.3.2.1, A.3.2.4","ČSN 44 4440, čl. 32 b)"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory typu A, indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze – zawory Badanie charakterystyki ciśnienie/przepływ Mechanizovaná výztuž – hydraulické ovládací systémy – ventily typu A, individuální porubní výztuž – důlní stojky hydraulické – ventily Zkouška chování tlak/průtok ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.7; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.7; ČSN 44 4450, příl. A.3.2, A.3.2.1, A.3.2.4; ČSN 44 4440, čl. 32 b) Obudowa zmechanizowana – hydrauliczne uklady sterowania – zawory typu A, indywidualna obudowa scianowa – hydrauliczne stojaki gornicze – zawory Badanie charakterystyki cisnienie/przeplyw Mechanizovana vyztuz – hydraulicke ovladaci systemy – ventily typu A, individualni porubni vyztuz – dulni stojky hydraulicke – ventily Zkouska chovani tlak/prutok CSN EN 1804-3, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.7; EN 1804-3, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.7; CSN 44 4450, pril. A.3.2, A.3.2.1, A.3.2.4; CSN 44 4440, cl. 32 b)","search_en":"Powered supports – hydraulic control systems – type A valves, individual reinforcement – hydraulic mine legs – valves Pressure/flow behaviour test ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.7; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.7; ČSN 44 4450, příl. A.3.2, A.3.2.1, A.3.2.4; ČSN 44 4440, čl. 32 b)","search_zh":"液压支架–液压控制系统–A型阀，单体采面支护–矿用液压支柱–阀门 压力/流量特性试验 ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.7; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.7; ČSN 44 4450, příl. A.3.2, A.3.2.1, A.3.2.4; ČSN 44 4440, čl. 32 b)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3116b6bdaf6d29b17e3e479c","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"30","test_object":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory, indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze","test_object_en":"Powered supports – hydraulic control systems – valves, individual reinforcement – hydraulic mine legs","test_object_zh":"液压支架–液压控制系统–阀门，单体采面支护–矿用液压支柱","test_object_cs":"Mechanizovaná výztuž – hydraulické ovládací systémy – ventily, individuální porubní výztuž – důlní stojky hydraulické","methodology":"Próba zmęczeniowa","methodology_en":"Fatigue test","methodology_zh":"疲劳试验","methodology_cs":"Zkouška na únavu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba zmęczeniowa","reference":"ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.8, A.1.4, A.1.4.1, A.1.4.6, A.1.5, A.1.5.1, A.1.5.4; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.8, A.1.4, A.1.4.1, A.1.4.6, A.1.5, A.1.5.1, A.1.5.4; ČSN 44 4450, příl. A.3.2, A.3.2.1, A.3.2.6; ČSN 44 4440, čl. 33","norm_bases":["ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.8, A.1.4, A.1.4.1, A.1.4.6, A.1.5, A.1.5.1, A.1.5.4","EN 1804-3, příl. A.1.1, A.1.3, A.1.3.8, A.1.4, A.1.4.1, A.1.4.6, A.1.5, A.1.5.1, A.1.5.4","ČSN 44 4450, příl. A.3.2, A.3.2.1, A.3.2.6","ČSN 44 4440, čl. 33"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory, indywidualna obudowa ścianowa – hydrauliczne stojaki górnicze Próba zmęczeniowa Mechanizovaná výztuž – hydraulické ovládací systémy – ventily, individuální porubní výztuž – důlní stojky hydraulické Zkouška na únavu ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.8, A.1.4, A.1.4.1, A.1.4.6, A.1.5, A.1.5.1, A.1.5.4; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.8, A.1.4, A.1.4.1, A.1.4.6, A.1.5, A.1.5.1, A.1.5.4; ČSN 44 4450, příl. A.3.2, A.3.2.1, A.3.2.6; ČSN 44 4440, čl. 33 Obudowa zmechanizowana – hydrauliczne uklady sterowania – zawory, indywidualna obudowa scianowa – hydrauliczne stojaki gornicze Proba zmeczeniowa Mechanizovana vyztuz – hydraulicke ovladaci systemy – ventily, individualni porubni vyztuz – dulni stojky hydraulicke Zkouska na unavu CSN EN 1804-3, pril. A.1.1, A.1.3, A.1.3.8, A.1.4, A.1.4.1, A.1.4.6, A.1.5, A.1.5.1, A.1.5.4; EN 1804-3, pril. A.1.1, A.1.3, A.1.3.8, A.1.4, A.1.4.1, A.1.4.6, A.1.5, A.1.5.1, A.1.5.4; CSN 44 4450, pril. A.3.2, A.3.2.1, A.3.2.6; CSN 44 4440, cl. 33","search_en":"Powered supports – hydraulic control systems – valves, individual reinforcement – hydraulic mine legs Fatigue test ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.8, A.1.4, A.1.4.1, A.1.4.6, A.1.5, A.1.5.1, A.1.5.4; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.8, A.1.4, A.1.4.1, A.1.4.6, A.1.5, A.1.5.1, A.1.5.4; ČSN 44 4450, příl. A.3.2, A.3.2.1, A.3.2.6; ČSN 44 4440, čl. 33","search_zh":"液压支架–液压控制系统–阀门，单体采面支护–矿用液压支柱 疲劳试验 ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.8, A.1.4, A.1.4.1, A.1.4.6, A.1.5, A.1.5.1, A.1.5.4; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.8, A.1.4, A.1.4.1, A.1.4.6, A.1.5, A.1.5.1, A.1.5.4; ČSN 44 4450, příl. A.3.2, A.3.2.1, A.3.2.6; ČSN 44 4440, čl. 33","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"beb8f093dca922c400abecf3","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"31","test_object":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory","test_object_en":"Roof support - Hydraulic control systems - valves","test_object_zh":"液压支架–液压控制系统–阀门","test_object_cs":"Mechanizovaná výztuž – hydraulické ovládací systémy – ventily","methodology":"Badanie odporności na ciśnienie zwrotne","methodology_en":"Back pressure resistance test","methodology_zh":"耐背压试验","methodology_cs":"Zkouška odolnosti vůči zpětnému tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na ciśnienie zwrotne","reference":"ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.9, A.1.4, A.1.4.1, A.1.4.4, A.1.5, A.1.5.1, A.1.5.5; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.9, A.1.4, A.1.4.1, A.1.4.4, A.1.5, A.1.5.1, A.1.5.5","norm_bases":["ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.9, A.1.4, A.1.4.1, A.1.4.4, A.1.5, A.1.5.1, A.1.5.5","EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.9, A.1.4, A.1.4.1, A.1.4.4, A.1.5, A.1.5.1, A.1.5.5"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – hydrauliczne układy sterowania – zawory Badanie odporności na ciśnienie zwrotne Mechanizovaná výztuž – hydraulické ovládací systémy – ventily Zkouška odolnosti vůči zpětnému tlaku ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.9, A.1.4, A.1.4.1, A.1.4.4, A.1.5, A.1.5.1, A.1.5.5; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.9, A.1.4, A.1.4.1, A.1.4.4, A.1.5, A.1.5.1, A.1.5.5 Obudowa zmechanizowana – hydrauliczne uklady sterowania – zawory Badanie odpornosci na cisnienie zwrotne Mechanizovana vyztuz – hydraulicke ovladaci systemy – ventily Zkouska odolnosti vuci zpetnemu tlaku CSN EN 1804-3, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.9, A.1.4, A.1.4.1, A.1.4.4, A.1.5, A.1.5.1, A.1.5.5; EN 1804-3, pril. A.1.1, A.1.3, A.1.3.1, A.1.3.9, A.1.4, A.1.4.1, A.1.4.4, A.1.5, A.1.5.1, A.1.5.5","search_en":"Roof support - Hydraulic control systems - valves Back pressure resistance test ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.9, A.1.4, A.1.4.1, A.1.4.4, A.1.5, A.1.5.1, A.1.5.5; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.9, A.1.4, A.1.4.1, A.1.4.4, A.1.5, A.1.5.1, A.1.5.5","search_zh":"液压支架–液压控制系统–阀门 耐背压试验 ČSN EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.9, A.1.4, A.1.4.1, A.1.4.4, A.1.5, A.1.5.1, A.1.5.5; EN 1804-3, příl. A.1.1, A.1.3, A.1.3.1, A.1.3.9, A.1.4, A.1.4.1, A.1.4.4, A.1.5, A.1.5.1, A.1.5.5","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"73ebcac68ece2dc1e5971ce1","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"32","test_object":"Obudowa zmechanizowana – hydrauliczne układy sterowania","test_object_en":"Roof support - Hydraulic control systems","test_object_zh":"液压支架–液压控制系统","test_object_cs":"Mechanizovaná výztuž – hydraulické ovládací systémy","methodology":"Próba przełączania (wyłączania)","methodology_en":"Switching test (Switching off)","methodology_zh":"切换（关闭）试验","methodology_cs":"Zkouška přepínání (vypínání)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba przełączania (wyłączania)","reference":"ČSN EN 1804-3, příl. A.1.1, A.1.4, A.1.4.1, A.1.4.5, A.1.5, A.1.5.1, A.1.5.6; EN 1804-3, příl. A.1.1, A.1.4, A.1.4.1, A.1.4.5, A.1.5, A.1.5.1, A.1.5.6","norm_bases":["ČSN EN 1804-3, příl. A.1.1, A.1.4, A.1.4.1, A.1.4.5, A.1.5, A.1.5.1, A.1.5.6","EN 1804-3, příl. A.1.1, A.1.4, A.1.4.1, A.1.4.5, A.1.5, A.1.5.1, A.1.5.6"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana – hydrauliczne układy sterowania Próba przełączania (wyłączania) Mechanizovaná výztuž – hydraulické ovládací systémy Zkouška přepínání (vypínání) ČSN EN 1804-3, příl. A.1.1, A.1.4, A.1.4.1, A.1.4.5, A.1.5, A.1.5.1, A.1.5.6; EN 1804-3, příl. A.1.1, A.1.4, A.1.4.1, A.1.4.5, A.1.5, A.1.5.1, A.1.5.6 Obudowa zmechanizowana – hydrauliczne uklady sterowania Proba przelaczania (wylaczania) Mechanizovana vyztuz – hydraulicke ovladaci systemy Zkouska prepinani (vypinani) CSN EN 1804-3, pril. A.1.1, A.1.4, A.1.4.1, A.1.4.5, A.1.5, A.1.5.1, A.1.5.6; EN 1804-3, pril. A.1.1, A.1.4, A.1.4.1, A.1.4.5, A.1.5, A.1.5.1, A.1.5.6","search_en":"Roof support - Hydraulic control systems Switching test (Switching off) ČSN EN 1804-3, příl. A.1.1, A.1.4, A.1.4.1, A.1.4.5, A.1.5, A.1.5.1, A.1.5.6; EN 1804-3, příl. A.1.1, A.1.4, A.1.4.1, A.1.4.5, A.1.5, A.1.5.1, A.1.5.6","search_zh":"液压支架–液压控制系统 切换（关闭）试验 ČSN EN 1804-3, příl. A.1.1, A.1.4, A.1.4.1, A.1.4.5, A.1.5, A.1.5.1, A.1.5.6; EN 1804-3, příl. A.1.1, A.1.4, A.1.4.1, A.1.4.5, A.1.5, A.1.5.1, A.1.5.6","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d5f6bf9177baa69a6273076c","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"33","test_object":"Obudowa zmechanizowana przeznaczona do pokładów zagrożonych tąpaniami","test_object_en":"Roof supports for coal seams affected by rock bursts","test_object_zh":"用于冲击地压危险煤层的液压支架","test_object_cs":"Mechanizovaná výztuž určena do slojí ohrožených otřesy","methodology":"Badanie odporności dynamicznej stojaka hydraulicznego (siłownika podporowego) we współpracy z zaworem upustowym","methodology_en":"Dynamic resistance test of hydraulic pit prop (support ram) – in cooperation with impact valve","methodology_zh":"液压支柱（支撑千斤顶）与冲击阀协同动态抗力试验","methodology_cs":"Zkouška dynamické odolnosti hydraulické stojky (podpěrného válce) v součinnosti s rázovým ventilem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności dynamicznej stojaka hydraulicznego (siłownika podporowego) we współpracy z zaworem upustowym","reference":"ČSN 44 4450, příl. A.2.3, A.2.3.1","norm_bases":["ČSN 44 4450, příl. A.2.3, A.2.3.1"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana przeznaczona do pokładów zagrożonych tąpaniami Badanie odporności dynamicznej stojaka hydraulicznego (siłownika podporowego) we współpracy z zaworem upustowym Mechanizovaná výztuž určena do slojí ohrožených otřesy Zkouška dynamické odolnosti hydraulické stojky (podpěrného válce) v součinnosti s rázovým ventilem ČSN 44 4450, příl. A.2.3, A.2.3.1 Obudowa zmechanizowana przeznaczona do pokladow zagrozonych tapaniami Badanie odpornosci dynamicznej stojaka hydraulicznego (silownika podporowego) we wspolpracy z zaworem upustowym Mechanizovana vyztuz urcena do sloji ohrozenych otresy Zkouska dynamicke odolnosti hydraulicke stojky (podperneho valce) v soucinnosti s razovym ventilem CSN 44 4450, pril. A.2.3, A.2.3.1","search_en":"Roof supports for coal seams affected by rock bursts Dynamic resistance test of hydraulic pit prop (support ram) – in cooperation with impact valve ČSN 44 4450, příl. A.2.3, A.2.3.1","search_zh":"用于冲击地压危险煤层的液压支架 液压支柱（支撑千斤顶）与冲击阀协同动态抗力试验 ČSN 44 4450, příl. A.2.3, A.2.3.1","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"19432b694c61dde2f52701e9","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"34","test_object":"Węże gumowe i z tworzyw sztucznych oraz węże z końcówkami","test_object_en":"Rubber and plastics hoses and hose assemblies","test_object_zh":"橡胶和塑料软管及软管组件","test_object_cs":"Pryžové a plastové hadice a hadice s koncovkami","methodology":"Próba statycznym ciśnieniem próbnym","methodology_en":"Static testing pressure test","methodology_zh":"静态试验压力试验","methodology_cs":"Zkouška statickým zkušebním tlakem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba statycznym ciśnieniem próbnym","reference":"ČSN EN ISO 1402, čl. 8.1; PN-G-32000:2011","norm_bases":["ČSN EN ISO 1402, čl. 8.1","PN-G-32000:2011"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węże gumowe i z tworzyw sztucznych oraz węże z końcówkami Próba statycznym ciśnieniem próbnym Pryžové a plastové hadice a hadice s koncovkami Zkouška statickým zkušebním tlakem ČSN EN ISO 1402, čl. 8.1; PN-G-32000:2011 Weze gumowe i z tworzyw sztucznych oraz weze z koncowkami Proba statycznym cisnieniem probnym Pryzove a plastove hadice a hadice s koncovkami Zkouska statickym zkusebnim tlakem CSN EN ISO 1402, cl. 8.1; PN-G-32000:2011","search_en":"Rubber and plastics hoses and hose assemblies Static testing pressure test ČSN EN ISO 1402, čl. 8.1; PN-G-32000:2011","search_zh":"橡胶和塑料软管及软管组件 静态试验压力试验 ČSN EN ISO 1402, čl. 8.1; PN-G-32000:2011","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2a4c0ee40fa0a2096c917e7e","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"35","test_object":"Węże gumowe i z tworzyw sztucznych oraz węże z końcówkami","test_object_en":"Rubber and plastics hoses and hose assemblies","test_object_zh":"橡胶和塑料软管及软管组件","test_object_cs":"Pryžové a plastové hadice a hadice s koncovkami","methodology":"Próba ciśnieniem niszczącym","methodology_en":"Emergency pressure test","methodology_zh":"爆破压力试验","methodology_cs":"Zkouška poruchovým tlakem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba ciśnieniem niszczącym","reference":"ČSN EN ISO 1402, čl. 8.3; PN-G-32000:2011","norm_bases":["ČSN EN ISO 1402, čl. 8.3","PN-G-32000:2011"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węże gumowe i z tworzyw sztucznych oraz węże z końcówkami Próba ciśnieniem niszczącym Pryžové a plastové hadice a hadice s koncovkami Zkouška poruchovým tlakem ČSN EN ISO 1402, čl. 8.3; PN-G-32000:2011 Weze gumowe i z tworzyw sztucznych oraz weze z koncowkami Proba cisnieniem niszczacym Pryzove a plastove hadice a hadice s koncovkami Zkouska poruchovym tlakem CSN EN ISO 1402, cl. 8.3; PN-G-32000:2011","search_en":"Rubber and plastics hoses and hose assemblies Emergency pressure test ČSN EN ISO 1402, čl. 8.3; PN-G-32000:2011","search_zh":"橡胶和塑料软管及软管组件 爆破压力试验 ČSN EN ISO 1402, čl. 8.3; PN-G-32000:2011","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5570988558b509f489b39d53","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"36","test_object":"Węże gumowe i z tworzyw sztucznych oraz węże z końcówkami","test_object_en":"Rubber and plastics hoses and hose assemblies","test_object_zh":"橡胶和塑料软管及软管组件","test_object_cs":"Pryžové a plastové hadice a hadice s koncovkami","methodology":"Badanie szczelności","methodology_en":"Leakage test","methodology_zh":"密封性试验","methodology_cs":"Zkouška těsnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie szczelności","reference":"ČSN EN ISO 1402, čl. 8.4; PN-G-32000:2011","norm_bases":["ČSN EN ISO 1402, čl. 8.4","PN-G-32000:2011"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Węże gumowe i z tworzyw sztucznych oraz węże z końcówkami Badanie szczelności Pryžové a plastové hadice a hadice s koncovkami Zkouška těsnosti ČSN EN ISO 1402, čl. 8.4; PN-G-32000:2011 Weze gumowe i z tworzyw sztucznych oraz weze z koncowkami Badanie szczelnosci Pryzove a plastove hadice a hadice s koncovkami Zkouska tesnosti CSN EN ISO 1402, cl. 8.4; PN-G-32000:2011","search_en":"Rubber and plastics hoses and hose assemblies Leakage test ČSN EN ISO 1402, čl. 8.4; PN-G-32000:2011","search_zh":"橡胶和塑料软管及软管组件 密封性试验 ČSN EN ISO 1402, čl. 8.4; PN-G-32000:2011","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"19fc3cc7e0bf6f0a919a6e33","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"37","test_object":"Stal","test_object_en":"Steel","test_object_zh":"钢","test_object_cs":"Ocel","methodology":"Próba rozciągania wraz z przygotowaniem próbki","methodology_en":"Tensile test including sample preparation","methodology_zh":"拉伸试验（含试样制备）","methodology_cs":"Zkoušení tahem včetně přípravy vzorku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba rozciągania wraz z przygotowaniem próbki","reference":"ČSN EN ISO 6892-1; ČSN EN ISO 377","norm_bases":["ČSN EN ISO 6892-1","ČSN EN ISO 377"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stal Próba rozciągania wraz z przygotowaniem próbki Ocel Zkoušení tahem včetně přípravy vzorku ČSN EN ISO 6892-1; ČSN EN ISO 377 Stal Proba rozciagania wraz z przygotowaniem probki Ocel Zkouseni tahem vcetne pripravy vzorku CSN EN ISO 6892-1; CSN EN ISO 377","search_en":"Steel Tensile test including sample preparation ČSN EN ISO 6892-1; ČSN EN ISO 377","search_zh":"钢 拉伸试验（含试样制备） ČSN EN ISO 6892-1; ČSN EN ISO 377","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1ed38601be90648afd174743","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"38","test_object":"Mechanizmy hydrostatyczne i hydrauliczne układy sterowania","test_object_en":"Hydrostatic mechanisms and hydraulic control systems","test_object_zh":"静液压机构和液压控制系统","test_object_cs":"Hydrostatické mechanismy a hydraulické ovládací systémy","methodology":"Kontrola wyglądu zewnętrznego i wyznaczanie wymiarów","methodology_en":"Inspection of external appearance and determination of dimensions","methodology_zh":"外观检查和尺寸测定","methodology_cs":"Kontrola vnějšího vzhledu a stanovení rozměrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Kontrola wyglądu zewnętrznego i wyznaczanie wymiarów","reference":"ČSN 11 9008, čl. 4.2; ČSN 44 4450, příl. A.3.1.2","norm_bases":["ČSN 11 9008, čl. 4.2","ČSN 44 4450, příl. A.3.1.2"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mechanizmy hydrostatyczne i hydrauliczne układy sterowania Kontrola wyglądu zewnętrznego i wyznaczanie wymiarów Hydrostatické mechanismy a hydraulické ovládací systémy Kontrola vnějšího vzhledu a stanovení rozměrů ČSN 11 9008, čl. 4.2; ČSN 44 4450, příl. A.3.1.2 Mechanizmy hydrostatyczne i hydrauliczne uklady sterowania Kontrola wygladu zewnetrznego i wyznaczanie wymiarow Hydrostaticke mechanismy a hydraulicke ovladaci systemy Kontrola vnejsiho vzhledu a stanoveni rozmeru CSN 11 9008, cl. 4.2; CSN 44 4450, pril. A.3.1.2","search_en":"Hydrostatic mechanisms and hydraulic control systems Inspection of external appearance and determination of dimensions ČSN 11 9008, čl. 4.2; ČSN 44 4450, příl. A.3.1.2","search_zh":"静液压机构和液压控制系统 外观检查和尺寸测定 ČSN 11 9008, čl. 4.2; ČSN 44 4450, příl. A.3.1.2","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"624f3c2df0b098cd29776f52","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"39","test_object":"Mechanizmy hydrostatyczne","test_object_en":"Hydrostatic mechanical devices","test_object_zh":"静液压机构","test_object_cs":"Hydrostatické mechanismy","methodology":"Badanie wytrzymałości ciśnieniowej","methodology_en":"Pressure strength test","methodology_zh":"耐压强度试验","methodology_cs":"Zkouška tlakové pevnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie wytrzymałości ciśnieniowej","reference":"ČSN 11 9008, čl. 4.4","norm_bases":["ČSN 11 9008, čl. 4.4"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mechanizmy hydrostatyczne Badanie wytrzymałości ciśnieniowej Hydrostatické mechanismy Zkouška tlakové pevnosti ČSN 11 9008, čl. 4.4 Mechanizmy hydrostatyczne Badanie wytrzymalosci cisnieniowej Hydrostaticke mechanismy Zkouska tlakove pevnosti CSN 11 9008, cl. 4.4","search_en":"Hydrostatic mechanical devices Pressure strength test ČSN 11 9008, čl. 4.4","search_zh":"静液压机构 耐压强度试验 ČSN 11 9008, čl. 4.4","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bdc09b28ba254878f37f9114","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"40","test_object":"Mechanizmy hydrostatyczne","test_object_en":"Hydrostatic mechanical devices","test_object_zh":"静液压机构","test_object_cs":"Hydrostatické mechanismy","methodology":"Badanie i kontrola działania","methodology_en":"Functionality test","methodology_zh":"功能试验和检查","methodology_cs":"Zkouška a kontrola funkce","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie i kontrola działania","reference":"ČSN 11 9008, čl. 4.7","norm_bases":["ČSN 11 9008, čl. 4.7"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mechanizmy hydrostatyczne Badanie i kontrola działania Hydrostatické mechanismy Zkouška a kontrola funkce ČSN 11 9008, čl. 4.7 Mechanizmy hydrostatyczne Badanie i kontrola dzialania Hydrostaticke mechanismy Zkouska a kontrola funkce CSN 11 9008, cl. 4.7","search_en":"Hydrostatic mechanical devices Functionality test ČSN 11 9008, čl. 4.7","search_zh":"静液压机构 功能试验和检查 ČSN 11 9008, čl. 4.7","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"14fe4d15cde1d40e79e5c90c","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"41","test_object":"Mechanizmy hydrostatyczne","test_object_en":"Hydrostatic mechanisms","test_object_zh":"静液压机构","test_object_cs":"Hydrostatické mechanismy","methodology":"Badanie niezawodności przy cyklicznym obciążeniu hydraulicznym","methodology_en":"Safety test under cyclic hydraulic loading","methodology_zh":"循环液压加载可靠性试验","methodology_cs":"Zkouška spolehlivosti při cyklickém hydraulickém zatěžování","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie niezawodności przy cyklicznym obciążeniu hydraulicznym","reference":"ČSN 11 9008, čl. 4.9","norm_bases":["ČSN 11 9008, čl. 4.9"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mechanizmy hydrostatyczne Badanie niezawodności przy cyklicznym obciążeniu hydraulicznym Hydrostatické mechanismy Zkouška spolehlivosti při cyklickém hydraulickém zatěžování ČSN 11 9008, čl. 4.9 Mechanizmy hydrostatyczne Badanie niezawodnosci przy cyklicznym obciazeniu hydraulicznym Hydrostaticke mechanismy Zkouska spolehlivosti pri cyklickem hydraulickem zatezovani CSN 11 9008, cl. 4.9","search_en":"Hydrostatic mechanisms Safety test under cyclic hydraulic loading ČSN 11 9008, čl. 4.9","search_zh":"静液压机构 循环液压加载可靠性试验 ČSN 11 9008, čl. 4.9","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a307fbc6ec299f7100e15eb2","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"42","test_object":"Maszyny, urządzenia i ich części","test_object_en":"Machinery, equipment and parts thereof","test_object_zh":"机械、设备及其零部件","test_object_cs":"Stroje, zařízení a jejich části","methodology":"Próba obciążenia siłą","methodology_en":"Force load test","methodology_zh":"力加载试验","methodology_cs":"Zkouška silovým zatížením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba obciążenia siłą","reference":"PP-42.04.03","norm_bases":["PP-42.04.03"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Maszyny, urządzenia i ich części Próba obciążenia siłą Stroje, zařízení a jejich části Zkouška silovým zatížením PP-42.04.03 Maszyny, urzadzenia i ich czesci Proba obciazenia sila Stroje, zarizeni a jejich casti Zkouska silovym zatizenim PP-42.04.03","search_en":"Machinery, equipment and parts thereof Force load test PP-42.04.03","search_zh":"机械、设备及其零部件 力加载试验 PP-42.04.03","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"87cc824e2e4a7a933a0b9cf8","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"43","test_object":"Stalowa obudowa górnicza","test_object_en":"Steel support for use in mines","test_object_zh":"矿用钢支护","test_object_cs":"Důlní ocelové výztuže","methodology":"Próba obciążenia siłą","methodology_en":"Force load test","methodology_zh":"力加载试验","methodology_cs":"Zkouška silovým zatížením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba obciążenia siłą","reference":"ČSN 44 4410-3; PN-87/G-15000/10; ČSN 44 4410-1, čl. 5.3; STN 44 4410-1, čl. 5.3; ČSN 44 4410-4, čl. 5.2; STN 44 4410-4, čl. 5.2; DIN 21530-4, čl. 4.1.1.2.2.5, 4.1.2.2.2; UNE 22725, čl. 4.2.3; PN-G-15026:2017-4","norm_bases":["ČSN 44 4410-3","PN-87/G-15000/10","ČSN 44 4410-1, čl. 5.3","STN 44 4410-1, čl. 5.3","ČSN 44 4410-4, čl. 5.2","STN 44 4410-4, čl. 5.2","DIN 21530-4, čl. 4.1.1.2.2.5, 4.1.2.2.2","UNE 22725, čl. 4.2.3","PN-G-15026:2017-4"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stalowa obudowa górnicza Próba obciążenia siłą Důlní ocelové výztuže Zkouška silovým zatížením ČSN 44 4410-3; PN-87/G-15000/10; ČSN 44 4410-1, čl. 5.3; STN 44 4410-1, čl. 5.3; ČSN 44 4410-4, čl. 5.2; STN 44 4410-4, čl. 5.2; DIN 21530-4, čl. 4.1.1.2.2.5, 4.1.2.2.2; UNE 22725, čl. 4.2.3; PN-G-15026:2017-4 Stalowa obudowa gornicza Proba obciazenia sila Dulni ocelove vyztuze Zkouska silovym zatizenim CSN 44 4410-3; PN-87/G-15000/10; CSN 44 4410-1, cl. 5.3; STN 44 4410-1, cl. 5.3; CSN 44 4410-4, cl. 5.2; STN 44 4410-4, cl. 5.2; DIN 21530-4, cl. 4.1.1.2.2.5, 4.1.2.2.2; UNE 22725, cl. 4.2.3; PN-G-15026:2017-4","search_en":"Steel support for use in mines Force load test ČSN 44 4410-3; PN-87/G-15000/10; ČSN 44 4410-1, čl. 5.3; STN 44 4410-1, čl. 5.3; ČSN 44 4410-4, čl. 5.2; STN 44 4410-4, čl. 5.2; DIN 21530-4, čl. 4.1.1.2.2.5, 4.1.2.2.2; UNE 22725, čl. 4.2.3; PN-G-15026:2017-4","search_zh":"矿用钢支护 力加载试验 ČSN 44 4410-3; PN-87/G-15000/10; ČSN 44 4410-1, čl. 5.3; STN 44 4410-1, čl. 5.3; ČSN 44 4410-4, čl. 5.2; STN 44 4410-4, čl. 5.2; DIN 21530-4, čl. 4.1.1.2.2.5, 4.1.2.2.2; UNE 22725, čl. 4.2.3; PN-G-15026:2017-4","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9972a27cd5c217e971169228","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"44","test_object":"Górnicze stalowe rozpory","test_object_en":"Steel mine studdles","test_object_zh":"矿用钢撑杆","test_object_cs":"Důlní ocelové rozpínky","methodology":"Próba obciążenia siłą","methodology_en":"Force loading test","methodology_zh":"力加载试验","methodology_cs":"Zkouška silovým zatížením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba obciążenia siłą","reference":"DIN 21530-4, čl. 4.1.3.2.2, 4.1.3.2.3","norm_bases":["DIN 21530-4, čl. 4.1.3.2.2, 4.1.3.2.3"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Górnicze stalowe rozpory Próba obciążenia siłą Důlní ocelové rozpínky Zkouška silovým zatížením DIN 21530-4, čl. 4.1.3.2.2, 4.1.3.2.3 Gornicze stalowe rozpory Proba obciazenia sila Dulni ocelove rozpinky Zkouska silovym zatizenim DIN 21530-4, cl. 4.1.3.2.2, 4.1.3.2.3","search_en":"Steel mine studdles Force loading test DIN 21530-4, čl. 4.1.3.2.2, 4.1.3.2.3","search_zh":"矿用钢撑杆 力加载试验 DIN 21530-4, čl. 4.1.3.2.2, 4.1.3.2.3","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c0f8881afe238b434b70f7af","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"45","test_object":"Śruby i nakrętki","test_object_en":"Screws and nuts","test_object_zh":"螺栓和螺母","test_object_cs":"Šrouby a matice","methodology":"Próba obciążenia siłą","methodology_en":"Force loading test","methodology_zh":"力加载试验","methodology_cs":"Zkouška silovým zatížením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba obciążenia siłą","reference":"ČSN EN ISO 898-1, čl. 9.2, 9.7; ČSN EN ISO 898-2, čl. 9.1","norm_bases":["ČSN EN ISO 898-1, čl. 9.2, 9.7","ČSN EN ISO 898-2, čl. 9.1"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Śruby i nakrętki Próba obciążenia siłą Šrouby a matice Zkouška silovým zatížením ČSN EN ISO 898-1, čl. 9.2, 9.7; ČSN EN ISO 898-2, čl. 9.1 Sruby i nakretki Proba obciazenia sila Srouby a matice Zkouska silovym zatizenim CSN EN ISO 898-1, cl. 9.2, 9.7; CSN EN ISO 898-2, cl. 9.1","search_en":"Screws and nuts Force loading test ČSN EN ISO 898-1, čl. 9.2, 9.7; ČSN EN ISO 898-2, čl. 9.1","search_zh":"螺栓和螺母 力加载试验 ČSN EN ISO 898-1, čl. 9.2, 9.7; ČSN EN ISO 898-2, čl. 9.1","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7ee158aa25bdd220c4b930ba","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"46","test_object":"Stojaki mechaniczne","test_object_en":"Mechanical legs","test_object_zh":"机械支柱","test_object_cs":"Mechanické stojky","methodology":"Próba obciążenia siłą","methodology_en":"Force loading test","methodology_zh":"力加载试验","methodology_cs":"Zkouška silovým zatížením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba obciążenia siłą","reference":"PN-G-15533, čl. 4.3.5","norm_bases":["PN-G-15533, čl. 4.3.5"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stojaki mechaniczne Próba obciążenia siłą Mechanické stojky Zkouška silovým zatížením PN-G-15533, čl. 4.3.5 Stojaki mechaniczne Proba obciazenia sila Mechanicke stojky Zkouska silovym zatizenim PN-G-15533, cl. 4.3.5","search_en":"Mechanical legs Force loading test PN-G-15533, čl. 4.3.5","search_zh":"机械支柱 力加载试验 PN-G-15533, čl. 4.3.5","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"af0e77d94d6661335cd91fa0","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"47","test_object":"Strzemiona","test_object_en":"Shackles","test_object_zh":"U形卡","test_object_cs":"Třmeny","methodology":"Próba obciążenia siłą – pomiar ugięcia","methodology_en":"Force loading test – deflection measurement","methodology_zh":"力加载试验–挠度测量","methodology_cs":"Zkouška silovým zatížením – měření průhybu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba obciążenia siłą – pomiar ugięcia","reference":"PN-G-46696, čl. 3.6.4","norm_bases":["PN-G-46696, čl. 3.6.4"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Strzemiona Próba obciążenia siłą – pomiar ugięcia Třmeny Zkouška silovým zatížením – měření průhybu PN-G-46696, čl. 3.6.4 Strzemiona Proba obciazenia sila – pomiar ugiecia Trmeny Zkouska silovym zatizenim – mereni pruhybu PN-G-46696, cl. 3.6.4","search_en":"Shackles Force loading test – deflection measurement PN-G-46696, čl. 3.6.4","search_zh":"U形卡 力加载试验–挠度测量 PN-G-46696, čl. 3.6.4","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"72b5240f86fb9c3e942ad225","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"48","test_object":"Złącza mechaniczne taśm przenośnikowych","test_object_en":"Mechanical joints of conveyor belts","test_object_zh":"输送带机械接头","test_object_cs":"Mechanické spoje dopravních pásů","methodology":"Próba obciążenia siłą","methodology_en":"Force loading test","methodology_zh":"力加载试验","methodology_cs":"Zkouška silovým zatížením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba obciążenia siłą","reference":"ČSN EN ISO 1120, čl. 7","norm_bases":["ČSN EN ISO 1120, čl. 7"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Złącza mechaniczne taśm przenośnikowych Próba obciążenia siłą Mechanické spoje dopravních pásů Zkouška silovým zatížením ČSN EN ISO 1120, čl. 7 Zlacza mechaniczne tasm przenosnikowych Proba obciazenia sila Mechanicke spoje dopravnich pasu Zkouska silovym zatizenim CSN EN ISO 1120, cl. 7","search_en":"Mechanical joints of conveyor belts Force loading test ČSN EN ISO 1120, čl. 7","search_zh":"输送带机械接头 力加载试验 ČSN EN ISO 1120, čl. 7","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0885f1076a9c9a69af0b507b","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"49","test_object":"Łańcuchy górnicze","test_object_en":"Mine chains","test_object_zh":"矿用链条","test_object_cs":"Důlní řetězy","methodology":"Próba obciążenia siłą","methodology_en":"Force loading test","methodology_zh":"力加载试验","methodology_cs":"Zkouška silovým zatížením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba obciążenia siłą","reference":"ČSN 02 3203; ČSN 02 3215:1987; DIN 22252; DIN 20637, čl. 8.4, 8.5; DIN 685-3, čl. 7.4, 7.6","norm_bases":["ČSN 02 3203","ČSN 02 3215:1987","DIN 22252","DIN 20637, čl. 8.4, 8.5","DIN 685-3, čl. 7.4, 7.6"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Łańcuchy górnicze Próba obciążenia siłą Důlní řetězy Zkouška silovým zatížením ČSN 02 3203; ČSN 02 3215:1987; DIN 22252; DIN 20637, čl. 8.4, 8.5; DIN 685-3, čl. 7.4, 7.6 Lancuchy gornicze Proba obciazenia sila Dulni retezy Zkouska silovym zatizenim CSN 02 3203; CSN 02 3215:1987; DIN 22252; DIN 20637, cl. 8.4, 8.5; DIN 685-3, cl. 7.4, 7.6","search_en":"Mine chains Force loading test ČSN 02 3203; ČSN 02 3215:1987; DIN 22252; DIN 20637, čl. 8.4, 8.5; DIN 685-3, čl. 7.4, 7.6","search_zh":"矿用链条 力加载试验 ČSN 02 3203; ČSN 02 3215:1987; DIN 22252; DIN 20637, čl. 8.4, 8.5; DIN 685-3, čl. 7.4, 7.6","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"05d2953a3790fefa7ad3e15d","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"50","test_object":"Górnicze stalowe stropnice przegubowe","test_object_en":"Articulated steel mining joists","test_object_zh":"矿用铰接钢顶梁","test_object_cs":"Důlní ocelové stropnice kloubové","methodology":"Próba obciążenia siłą","methodology_en":"Force loading test","methodology_zh":"力加载试验","methodology_cs":"Zkouška silovým zatížením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba obciążenia siłą","reference":"PP-42.01.03 (PN-G-15541; PN-G-15542; PN-G-15543; PN-G-15544; PN-G-15545; ON 44 4418:1982)","norm_bases":["PP-42.01.03","PN-G-15541","PN-G-15542","PN-G-15543","PN-G-15544","PN-G-15545","ON 44 4418:1982"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Górnicze stalowe stropnice przegubowe Próba obciążenia siłą Důlní ocelové stropnice kloubové Zkouška silovým zatížením PP-42.01.03 (PN-G-15541; PN-G-15542; PN-G-15543; PN-G-15544; PN-G-15545; ON 44 4418:1982) Gornicze stalowe stropnice przegubowe Proba obciazenia sila Dulni ocelove stropnice kloubove Zkouska silovym zatizenim PP-42.01.03 (PN-G-15541; PN-G-15542; PN-G-15543; PN-G-15544; PN-G-15545; ON 44 4418:1982)","search_en":"Articulated steel mining joists Force loading test PP-42.01.03 (PN-G-15541; PN-G-15542; PN-G-15543; PN-G-15544; PN-G-15545; ON 44 4418:1982)","search_zh":"矿用铰接钢顶梁 力加载试验 PP-42.01.03 (PN-G-15541; PN-G-15542; PN-G-15543; PN-G-15544; PN-G-15545; ON 44 4418:1982)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f9cab709a9e61e897e7e78b5","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"51","test_object":"Magnesy trwałe do podnoszenia ładunków","test_object_en":"Permanent lifting magnets","test_object_zh":"永磁起重器","test_object_cs":"Permanentní břemenové magnety","methodology":"Próba obciążenia siłą","methodology_en":"Force loading test","methodology_zh":"力加载试验","methodology_cs":"Zkouška silovým zatížením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba obciążenia siłą","reference":"SN EN 13155+A2, čl. 5.2.3.4.1","norm_bases":["SN EN 13155+A2, čl. 5.2.3.4.1"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Magnesy trwałe do podnoszenia ładunków Próba obciążenia siłą Permanentní břemenové magnety Zkouška silovým zatížením SN EN 13155+A2, čl. 5.2.3.4.1 Magnesy trwale do podnoszenia ladunkow Proba obciazenia sila Permanentni bremenove magnety Zkouska silovym zatizenim SN EN 13155+A2, cl. 5.2.3.4.1","search_en":"Permanent lifting magnets Force loading test SN EN 13155+A2, čl. 5.2.3.4.1","search_zh":"永磁起重器 力加载试验 SN EN 13155+A2, čl. 5.2.3.4.1","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5dc3048423e5eba27a766721","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"52","test_object":"Stalowa obudowa górnicza","test_object_en":"Steel supports","test_object_zh":"矿用钢支护","test_object_cs":"Důlní ocelové výztuže","methodology":"Próba obciążenia siłą z poślizgiem","methodology_en":"Force load test with yield","methodology_zh":"带滑移的力加载试验","methodology_cs":"Zkouška silovým zatížením s prokluzem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba obciążenia siłą z poślizgiem","reference":"ČSN 44 4410-4, čl. 5.1; STN 44 4410-4, čl. 5.1; DIN 21530-4, čl. 4.1.2.2.3; UNE 22725, čl. 4.2.2; PN-G-15026:2017-4","norm_bases":["ČSN 44 4410-4, čl. 5.1","STN 44 4410-4, čl. 5.1","DIN 21530-4, čl. 4.1.2.2.3","UNE 22725, čl. 4.2.2","PN-G-15026:2017-4"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stalowa obudowa górnicza Próba obciążenia siłą z poślizgiem Důlní ocelové výztuže Zkouška silovým zatížením s prokluzem ČSN 44 4410-4, čl. 5.1; STN 44 4410-4, čl. 5.1; DIN 21530-4, čl. 4.1.2.2.3; UNE 22725, čl. 4.2.2; PN-G-15026:2017-4 Stalowa obudowa gornicza Proba obciazenia sila z poslizgiem Dulni ocelove vyztuze Zkouska silovym zatizenim s prokluzem CSN 44 4410-4, cl. 5.1; STN 44 4410-4, cl. 5.1; DIN 21530-4, cl. 4.1.2.2.3; UNE 22725, cl. 4.2.2; PN-G-15026:2017-4","search_en":"Steel supports Force load test with yield ČSN 44 4410-4, čl. 5.1; STN 44 4410-4, čl. 5.1; DIN 21530-4, čl. 4.1.2.2.3; UNE 22725, čl. 4.2.2; PN-G-15026:2017-4","search_zh":"矿用钢支护 带滑移的力加载试验 ČSN 44 4410-4, čl. 5.1; STN 44 4410-4, čl. 5.1; DIN 21530-4, čl. 4.1.2.2.3; UNE 22725, čl. 4.2.2; PN-G-15026:2017-4","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f1b06873a088e800ac1bb6d5","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"53","test_object":"Stojaki mechaniczne","test_object_en":"Mechanical legs","test_object_zh":"机械支柱","test_object_cs":"Mechanické stojky","methodology":"Próba obciążenia siłą z poślizgiem","methodology_en":"Force load test with slippage","methodology_zh":"带滑移的力加载试验","methodology_cs":"Zkouška silovým zatížením s prokluzem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba obciążenia siłą z poślizgiem","reference":"PN-G-15533, čl. 4.3.4, 4.3.6, 4.3.7","norm_bases":["PN-G-15533, čl. 4.3.4, 4.3.6, 4.3.7"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stojaki mechaniczne Próba obciążenia siłą z poślizgiem Mechanické stojky Zkouška silovým zatížením s prokluzem PN-G-15533, čl. 4.3.4, 4.3.6, 4.3.7 Stojaki mechaniczne Proba obciazenia sila z poslizgiem Mechanicke stojky Zkouska silovym zatizenim s prokluzem PN-G-15533, cl. 4.3.4, 4.3.6, 4.3.7","search_en":"Mechanical legs Force load test with slippage PN-G-15533, čl. 4.3.4, 4.3.6, 4.3.7","search_zh":"机械支柱 带滑移的力加载试验 PN-G-15533, čl. 4.3.4, 4.3.6, 4.3.7","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0d8a08192ec894975a0cd09f","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"54","test_object":"Druty stalowych lin długich","test_object_en":"Steel rope wires","test_object_zh":"钢丝绳用钢丝","test_object_cs":"Dráty ocelových délkových lan","methodology":"Wyznaczanie średnicy","methodology_en":"Determination of diameter","methodology_zh":"直径测定","methodology_cs":"Stanovení průměru","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie średnicy","reference":"ČSN 02 4301:1974, čl. 32, 54, 55; ČSN EN 10218-2","norm_bases":["ČSN 02 4301:1974, čl. 32, 54, 55","ČSN EN 10218-2"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Druty stalowych lin długich Wyznaczanie średnicy Dráty ocelových délkových lan Stanovení průměru ČSN 02 4301:1974, čl. 32, 54, 55; ČSN EN 10218-2 Druty stalowych lin dlugich Wyznaczanie srednicy Draty ocelovych delkovych lan Stanoveni prumeru CSN 02 4301:1974, cl. 32, 54, 55; CSN EN 10218-2","search_en":"Steel rope wires Determination of diameter ČSN 02 4301:1974, čl. 32, 54, 55; ČSN EN 10218-2","search_zh":"钢丝绳用钢丝 直径测定 ČSN 02 4301:1974, čl. 32, 54, 55; ČSN EN 10218-2","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ff4630e52b6f55c532c217b2","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"55","test_object":"Druty stalowych lin długich","test_object_en":"Steel rope wires","test_object_zh":"钢丝绳用钢丝","test_object_cs":"Dráty ocelových délkových lan","methodology":"Wyznaczanie liczby przegięć","methodology_en":"Enumeration of bends","methodology_zh":"弯曲次数测定","methodology_cs":"Stanovení počtu ohybů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie liczby przegięć","reference":"ČSN 02 4301:1974, čl. 36, 54, 55; ČSN ISO 7801","norm_bases":["ČSN 02 4301:1974, čl. 36, 54, 55","ČSN ISO 7801"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Druty stalowych lin długich Wyznaczanie liczby przegięć Dráty ocelových délkových lan Stanovení počtu ohybů ČSN 02 4301:1974, čl. 36, 54, 55; ČSN ISO 7801 Druty stalowych lin dlugich Wyznaczanie liczby przegiec Draty ocelovych delkovych lan Stanoveni poctu ohybu CSN 02 4301:1974, cl. 36, 54, 55; CSN ISO 7801","search_en":"Steel rope wires Enumeration of bends ČSN 02 4301:1974, čl. 36, 54, 55; ČSN ISO 7801","search_zh":"钢丝绳用钢丝 弯曲次数测定 ČSN 02 4301:1974, čl. 36, 54, 55; ČSN ISO 7801","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4d7a9d5b8d324e09d328da06","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"56","test_object":"Druty stalowych lin długich (do Ø drutu 5 mm)","test_object_en":"Steel rope wires (up to wire Ø 5mm)","test_object_zh":"钢丝绳用钢丝（钢丝直径不超过5 mm）","test_object_cs":"Dráty ocelových délkových lan (do Ø drátu 5 mm)","methodology":"Wyznaczanie liczby skręceń","methodology_en":"Enumeration of twists","methodology_zh":"扭转次数测定","methodology_cs":"Stanovení počtu krutů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie liczby skręceń","reference":"ČSN 02 4301:1974, čl. 37, 54, 55; ČSN ISO 7800","norm_bases":["ČSN 02 4301:1974, čl. 37, 54, 55","ČSN ISO 7800"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Druty stalowych lin długich (do Ø drutu 5 mm) Wyznaczanie liczby skręceń Dráty ocelových délkových lan (do Ø drátu 5 mm) Stanovení počtu krutů ČSN 02 4301:1974, čl. 37, 54, 55; ČSN ISO 7800 Druty stalowych lin dlugich (do Ø drutu 5 mm) Wyznaczanie liczby skrecen Draty ocelovych delkovych lan (do Ø dratu 5 mm) Stanoveni poctu krutu CSN 02 4301:1974, cl. 37, 54, 55; CSN ISO 7800","search_en":"Steel rope wires (up to wire Ø 5mm) Enumeration of twists ČSN 02 4301:1974, čl. 37, 54, 55; ČSN ISO 7800","search_zh":"钢丝绳用钢丝（钢丝直径不超过5 mm） 扭转次数测定 ČSN 02 4301:1974, čl. 37, 54, 55; ČSN ISO 7800","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"22e6b5f53e3917529f05f91e","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"57","test_object":"Liny stalowe długie","test_object_en":"Steel wire linear ropes","test_object_zh":"钢丝绳","test_object_cs":"Ocelová lana délková","methodology":"Wyznaczanie nośności w całości","methodology_en":"Determination of total bearing capacity","methodology_zh":"整绳承载力测定","methodology_cs":"Stanovení únosnosti v celku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie nośności w całości","reference":"ČSN 02 4301:1974, čl. 39, 40, 41, 43, 44; ČSN EN 12385-1+A1, čl. 6.4","norm_bases":["ČSN 02 4301:1974, čl. 39, 40, 41, 43, 44","ČSN EN 12385-1+A1, čl. 6.4"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Liny stalowe długie Wyznaczanie nośności w całości Ocelová lana délková Stanovení únosnosti v celku ČSN 02 4301:1974, čl. 39, 40, 41, 43, 44; ČSN EN 12385-1+A1, čl. 6.4 Liny stalowe dlugie Wyznaczanie nosnosci w calosci Ocelova lana delkova Stanoveni unosnosti v celku CSN 02 4301:1974, cl. 39, 40, 41, 43, 44; CSN EN 12385-1+A1, cl. 6.4","search_en":"Steel wire linear ropes Determination of total bearing capacity ČSN 02 4301:1974, čl. 39, 40, 41, 43, 44; ČSN EN 12385-1+A1, čl. 6.4","search_zh":"钢丝绳 整绳承载力测定 ČSN 02 4301:1974, čl. 39, 40, 41, 43, 44; ČSN EN 12385-1+A1, čl. 6.4","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f818e369bee16998baae1656","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"58","test_object":"Liny stalowe długie i liny z oczkami","test_object_en":"Steel wire ropes and ropes with eyes","test_object_zh":"钢丝绳及带环眼钢丝绳","test_object_cs":"Ocelová lana délková a lana s oky","methodology":"Wyznaczanie średnicy","methodology_en":"Determination of diameter","methodology_zh":"直径测定","methodology_cs":"Stanovení průměru","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie średnicy","reference":"ČSN 02 4301:1974, čl. 31; ČSN EN 12385-1+A1, čl. 6.3","norm_bases":["ČSN 02 4301:1974, čl. 31","ČSN EN 12385-1+A1, čl. 6.3"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Liny stalowe długie i liny z oczkami Wyznaczanie średnicy Ocelová lana délková a lana s oky Stanovení průměru ČSN 02 4301:1974, čl. 31; ČSN EN 12385-1+A1, čl. 6.3 Liny stalowe dlugie i liny z oczkami Wyznaczanie srednicy Ocelova lana delkova a lana s oky Stanoveni prumeru CSN 02 4301:1974, cl. 31; CSN EN 12385-1+A1, cl. 6.3","search_en":"Steel wire ropes and ropes with eyes Determination of diameter ČSN 02 4301:1974, čl. 31; ČSN EN 12385-1+A1, čl. 6.3","search_zh":"钢丝绳及带环眼钢丝绳 直径测定 ČSN 02 4301:1974, čl. 31; ČSN EN 12385-1+A1, čl. 6.3","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"00fb70607684793fa684774a","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"59","test_object":"Liny stalowe z oczkami","test_object_en":"Steel ropes with eyes","test_object_zh":"带环眼钢丝绳","test_object_cs":"Ocelová lana s oky","methodology":"Wyznaczanie rzeczywistej nośności","methodology_en":"Determination of actual load-bearing capacity","methodology_zh":"实际承载力测定","methodology_cs":"Stanovení skutečné únosnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie rzeczywistej nośności","reference":"ČSN 02 4481:1981, čl. 21; ČSN 02 4468, čl. 5; ČSN EN 13411-3:2023","norm_bases":["ČSN 02 4481:1981, čl. 21","ČSN 02 4468, čl. 5","ČSN EN 13411-3:2023"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Liny stalowe z oczkami Wyznaczanie rzeczywistej nośności Ocelová lana s oky Stanovení skutečné únosnosti ČSN 02 4481:1981, čl. 21; ČSN 02 4468, čl. 5; ČSN EN 13411-3:2023 Liny stalowe z oczkami Wyznaczanie rzeczywistej nosnosci Ocelova lana s oky Stanoveni skutecne unosnosti CSN 02 4481:1981, cl. 21; CSN 02 4468, cl. 5; CSN EN 13411-3:2023","search_en":"Steel ropes with eyes Determination of actual load-bearing capacity ČSN 02 4481:1981, čl. 21; ČSN 02 4468, čl. 5; ČSN EN 13411-3:2023","search_zh":"带环眼钢丝绳 实际承载力测定 ČSN 02 4481:1981, čl. 21; ČSN 02 4468, čl. 5; ČSN EN 13411-3:2023","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a52c74c67c7e2b9f05c0495c","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"60","test_object":"Oczka lin stalowych","test_object_en":"Eyes of steel wire ropes","test_object_zh":"钢丝绳环眼","test_object_cs":"Oka ocelových lan","methodology":"Wyznaczanie wymiarów","methodology_en":"Determination of dimensions","methodology_zh":"尺寸测定","methodology_cs":"Stanovení rozměrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie wymiarów","reference":"ČSN 02 4481:1981, čl. 25, 26; ČSN EN 13411-3:2023","norm_bases":["ČSN 02 4481:1981, čl. 25, 26","ČSN EN 13411-3:2023"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Oczka lin stalowych Wyznaczanie wymiarów Oka ocelových lan Stanovení rozměrů ČSN 02 4481:1981, čl. 25, 26; ČSN EN 13411-3:2023 Oczka lin stalowych Wyznaczanie wymiarow Oka ocelovych lan Stanoveni rozmeru CSN 02 4481:1981, cl. 25, 26; CSN EN 13411-3:2023","search_en":"Eyes of steel wire ropes Determination of dimensions ČSN 02 4481:1981, čl. 25, 26; ČSN EN 13411-3:2023","search_zh":"钢丝绳环眼 尺寸测定 ČSN 02 4481:1981, čl. 25, 26; ČSN EN 13411-3:2023","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"711b8f0be2c7bdd1247b624d","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"61","test_object":"Zaprasowane końce liny stalowej z oczkami","test_object_en":"Ferrules of wire ropes with eyes","test_object_zh":"带环眼钢丝绳压制端头","test_object_cs":"Nalisované konce ocelového lana s oky","methodology":"Wyznaczanie naddatku","methodology_en":"Determination of overlap","methodology_zh":"搭接量测定","methodology_cs":"Stanovení přesahu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie naddatku","reference":"ČSN 02 4481:1981, čl. 10; ČSN EN 13411-3:2023","norm_bases":["ČSN 02 4481:1981, čl. 10","ČSN EN 13411-3:2023"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zaprasowane końce liny stalowej z oczkami Wyznaczanie naddatku Nalisované konce ocelového lana s oky Stanovení přesahu ČSN 02 4481:1981, čl. 10; ČSN EN 13411-3:2023 Zaprasowane konce liny stalowej z oczkami Wyznaczanie naddatku Nalisovane konce oceloveho lana s oky Stanoveni presahu CSN 02 4481:1981, cl. 10; CSN EN 13411-3:2023","search_en":"Ferrules of wire ropes with eyes Determination of overlap ČSN 02 4481:1981, čl. 10; ČSN EN 13411-3:2023","search_zh":"带环眼钢丝绳压制端头 搭接量测定 ČSN 02 4481:1981, čl. 10; ČSN EN 13411-3:2023","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ed290d15e64019a3afcbd755","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"62","test_object":"Zaprasowane tuleje liny stalowej z oczkami","test_object_en":"Sleeves of wire ropes with eyes","test_object_zh":"带环眼钢丝绳压制套管","test_object_cs":"Nalisované objímky ocelového lana s oky","methodology":"Wyznaczanie wymiarów","methodology_en":"Determination of dimensions","methodology_zh":"尺寸测定","methodology_cs":"Stanovení rozměrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie wymiarów","reference":"ČSN 02 4481:1981, čl. 23, 24; ČSN EN 13411-3:2023","norm_bases":["ČSN 02 4481:1981, čl. 23, 24","ČSN EN 13411-3:2023"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zaprasowane tuleje liny stalowej z oczkami Wyznaczanie wymiarów Nalisované objímky ocelového lana s oky Stanovení rozměrů ČSN 02 4481:1981, čl. 23, 24; ČSN EN 13411-3:2023 Zaprasowane tuleje liny stalowej z oczkami Wyznaczanie wymiarow Nalisovane objimky oceloveho lana s oky Stanoveni rozmeru CSN 02 4481:1981, cl. 23, 24; CSN EN 13411-3:2023","search_en":"Sleeves of wire ropes with eyes Determination of dimensions ČSN 02 4481:1981, čl. 23, 24; ČSN EN 13411-3:2023","search_zh":"带环眼钢丝绳压制套管 尺寸测定 ČSN 02 4481:1981, čl. 23, 24; ČSN EN 13411-3:2023","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ebf0efaeb902918253231f2d","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"63","test_object":"Jezdne maszyny robocze, maszyny i urządzenia stacjonarne","test_object_en":"Mobile working machines, stationary machines and equipment","test_object_zh":"移动式工作机械、固定式机械和设备","test_object_cs":"Pojízdné pracovní stroje, stacionární stroje a zařízení","methodology":"Pomiar wielkości sił sterowania","methodology_en":"Operating force measurement","methodology_zh":"操作力测量","methodology_cs":"Měření velikosti ovládacích sil","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar wielkości sił sterowania","reference":"PP-42.04.07 (ČSN EN 894-3+A1); NV č. 361/2007 Sb., příl. č. 8 a 9","norm_bases":["PP-42.04.07","ČSN EN 894-3+A1","NV č. 361/2007 Sb., příl. č. 8 a 9"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Jezdne maszyny robocze, maszyny i urządzenia stacjonarne Pomiar wielkości sił sterowania Pojízdné pracovní stroje, stacionární stroje a zařízení Měření velikosti ovládacích sil PP-42.04.07 (ČSN EN 894-3+A1); NV č. 361/2007 Sb., příl. č. 8 a 9 Jezdne maszyny robocze, maszyny i urzadzenia stacjonarne Pomiar wielkosci sil sterowania Pojizdne pracovni stroje, stacionarni stroje a zarizeni Mereni velikosti ovladacich sil PP-42.04.07 (CSN EN 894-3+A1); NV c. 361/2007 Sb., pril. c. 8 a 9","search_en":"Mobile working machines, stationary machines and equipment Operating force measurement PP-42.04.07 (ČSN EN 894-3+A1); NV č. 361/2007 Sb., příl. č. 8 a 9","search_zh":"移动式工作机械、固定式机械和设备 操作力测量 PP-42.04.07 (ČSN EN 894-3+A1); NV č. 361/2007 Sb., příl. č. 8 a 9","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7028a943196730491b5a5bf7","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"64","test_object":"Komplet stalowej obudowy górniczej","test_object_en":"Mining steel reinforcement assemblies","test_object_zh":"矿用钢支护组件","test_object_cs":"Komplet důlní ocelové výztuže","methodology":"Wyznaczanie masy części","methodology_en":"Determination of mass of components","methodology_zh":"零件质量测定","methodology_cs":"Stanovení hmotnosti dílů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie masy części","reference":"ČSN 44 4410-2, čl. 4.1","norm_bases":["ČSN 44 4410-2, čl. 4.1"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Komplet stalowej obudowy górniczej Wyznaczanie masy części Komplet důlní ocelové výztuže Stanovení hmotnosti dílů ČSN 44 4410-2, čl. 4.1 Komplet stalowej obudowy gorniczej Wyznaczanie masy czesci Komplet dulni ocelove vyztuze Stanoveni hmotnosti dilu CSN 44 4410-2, cl. 4.1","search_en":"Mining steel reinforcement assemblies Determination of mass of components ČSN 44 4410-2, čl. 4.1","search_zh":"矿用钢支护组件 零件质量测定 ČSN 44 4410-2, čl. 4.1","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"499b1f6b99f713f809eed09e","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"65","test_object":"Pręty kształtowe","test_object_en":"Profile bars","test_object_zh":"型钢","test_object_cs":"Tvarové tyče","methodology":"Wyznaczanie masy części","methodology_en":"Determination of weight of parts","methodology_zh":"零件质量测定","methodology_cs":"Stanovení hmotnosti dílů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie masy części","reference":"ČSN 44 4410-1, čl. 5.1; STN 44 4410-1, čl. 5.1","norm_bases":["ČSN 44 4410-1, čl. 5.1","STN 44 4410-1, čl. 5.1"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pręty kształtowe Wyznaczanie masy części Tvarové tyče Stanovení hmotnosti dílů ČSN 44 4410-1, čl. 5.1; STN 44 4410-1, čl. 5.1 Prety ksztaltowe Wyznaczanie masy czesci Tvarove tyce Stanoveni hmotnosti dilu CSN 44 4410-1, cl. 5.1; STN 44 4410-1, cl. 5.1","search_en":"Profile bars Determination of weight of parts ČSN 44 4410-1, čl. 5.1; STN 44 4410-1, čl. 5.1","search_zh":"型钢 零件质量测定 ČSN 44 4410-1, čl. 5.1; STN 44 4410-1, čl. 5.1","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5d4fd45b81d3b4d963612235","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"66","test_object":"Górnicze stalowe stropnice przegubowe","test_object_en":"Articulated steel mine joists","test_object_zh":"矿用铰接钢顶梁","test_object_cs":"Důlní ocelové stropnice kloubové","methodology":"Wyznaczanie masy części","methodology_en":"Determination of weight of parts","methodology_zh":"零件质量测定","methodology_cs":"Stanovení hmotnosti dílů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wyznaczanie masy części","reference":"PP-42.01.02, čl. 4.2.4 (ON 44 4418:1982)","norm_bases":["PP-42.01.02, čl. 4.2.4","ON 44 4418:1982"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Górnicze stalowe stropnice przegubowe Wyznaczanie masy części Důlní ocelové stropnice kloubové Stanovení hmotnosti dílů PP-42.01.02, čl. 4.2.4 (ON 44 4418:1982) Gornicze stalowe stropnice przegubowe Wyznaczanie masy czesci Dulni ocelove stropnice kloubove Stanoveni hmotnosti dilu PP-42.01.02, cl. 4.2.4 (ON 44 4418:1982)","search_en":"Articulated steel mine joists Determination of weight of parts PP-42.01.02, čl. 4.2.4 (ON 44 4418:1982)","search_zh":"矿用铰接钢顶梁 零件质量测定 PP-42.01.02, čl. 4.2.4 (ON 44 4418:1982)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"99548d8cd191b04ca67ac00f","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"67","test_object":"Pręty kształtowe","test_object_en":"Profile bars","test_object_zh":"型钢","test_object_cs":"Tvarové tyče","methodology":"Pomiar wymiarów","methodology_en":"Measurement of dimensions","methodology_zh":"尺寸测量","methodology_cs":"Měření rozměrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar wymiarów","reference":"ČSN 44 4410-1, čl. 5.2; STN 44 4410-1, čl. 5.2","norm_bases":["ČSN 44 4410-1, čl. 5.2","STN 44 4410-1, čl. 5.2"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pręty kształtowe Pomiar wymiarów Tvarové tyče Měření rozměrů ČSN 44 4410-1, čl. 5.2; STN 44 4410-1, čl. 5.2 Prety ksztaltowe Pomiar wymiarow Tvarove tyce Mereni rozmeru CSN 44 4410-1, cl. 5.2; STN 44 4410-1, cl. 5.2","search_en":"Profile bars Measurement of dimensions ČSN 44 4410-1, čl. 5.2; STN 44 4410-1, čl. 5.2","search_zh":"型钢 尺寸测量 ČSN 44 4410-1, čl. 5.2; STN 44 4410-1, čl. 5.2","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e00c5e4407df5458455caee2","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"68","test_object":"Komplet stalowej obudowy górniczej","test_object_en":"Mining steel reinforcement assemblies","test_object_zh":"矿用钢支护组件","test_object_cs":"Komplet důlní ocelové výztuže","methodology":"Pomiar wymiarów","methodology_en":"Measurement of dimensions","methodology_zh":"尺寸测量","methodology_cs":"Měření rozměrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar wymiarów","reference":"ČSN 44 4410-2, čl. 4.2, 4.3, 4.4","norm_bases":["ČSN 44 4410-2, čl. 4.2, 4.3, 4.4"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Komplet stalowej obudowy górniczej Pomiar wymiarów Komplet důlní ocelové výztuže Měření rozměrů ČSN 44 4410-2, čl. 4.2, 4.3, 4.4 Komplet stalowej obudowy gorniczej Pomiar wymiarow Komplet dulni ocelove vyztuze Mereni rozmeru CSN 44 4410-2, cl. 4.2, 4.3, 4.4","search_en":"Mining steel reinforcement assemblies Measurement of dimensions ČSN 44 4410-2, čl. 4.2, 4.3, 4.4","search_zh":"矿用钢支护组件 尺寸测量 ČSN 44 4410-2, čl. 4.2, 4.3, 4.4","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ed9311488e8e8f240a0598c3","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"69","test_object":"Części złączne","test_object_en":"Connecting parts","test_object_zh":"连接件","test_object_cs":"Spojovací části","methodology":"Pomiar wymiarów","methodology_en":"Measurement of dimensions","methodology_zh":"尺寸测量","methodology_cs":"Měření rozměrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar wymiarów","reference":"ČSN 44 4410-3, čl. 4.1; PN-G-15011:2011","norm_bases":["ČSN 44 4410-3, čl. 4.1","PN-G-15011:2011"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Części złączne Pomiar wymiarów Spojovací části Měření rozměrů ČSN 44 4410-3, čl. 4.1; PN-G-15011:2011 Czesci zlaczne Pomiar wymiarow Spojovaci casti Mereni rozmeru CSN 44 4410-3, cl. 4.1; PN-G-15011:2011","search_en":"Connecting parts Measurement of dimensions ČSN 44 4410-3, čl. 4.1; PN-G-15011:2011","search_zh":"连接件 尺寸测量 ČSN 44 4410-3, čl. 4.1; PN-G-15011:2011","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c5a8ac4b478fdd3b65267630","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"70","test_object":"Łańcuchy","test_object_en":"Chains","test_object_zh":"链条","test_object_cs":"Řetězy","methodology":"Pomiar wymiarów","methodology_en":"Measurement of dimensions","methodology_zh":"尺寸测量","methodology_cs":"Měření rozměrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar wymiarów","reference":"DIN 22252, čl. 6.4.1; DIN 20637, čl. 8.3; DIN 685-3, čl. 7.3","norm_bases":["DIN 22252, čl. 6.4.1","DIN 20637, čl. 8.3","DIN 685-3, čl. 7.3"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Łańcuchy Pomiar wymiarów Řetězy Měření rozměrů DIN 22252, čl. 6.4.1; DIN 20637, čl. 8.3; DIN 685-3, čl. 7.3 Lancuchy Pomiar wymiarow Retezy Mereni rozmeru DIN 22252, cl. 6.4.1; DIN 20637, cl. 8.3; DIN 685-3, cl. 7.3","search_en":"Chains Measurement of dimensions DIN 22252, čl. 6.4.1; DIN 20637, čl. 8.3; DIN 685-3, čl. 7.3","search_zh":"链条 尺寸测量 DIN 22252, čl. 6.4.1; DIN 20637, čl. 8.3; DIN 685-3, čl. 7.3","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"07e3a5f811be5699e09c7c4a","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"71","test_object":"Górnicze stalowe stropnice przegubowe","test_object_en":"Articulated steel mine joists","test_object_zh":"矿用铰接钢顶梁","test_object_cs":"Důlní ocelové stropnice kloubové","methodology":"Pomiar wymiarów","methodology_en":"Measurement of dimensions","methodology_zh":"尺寸测量","methodology_cs":"Měření rozměrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar wymiarów","reference":"PP-42.01.02, čl. 4.2.3 (ON 44 4418:1982)","norm_bases":["PP-42.01.02, čl. 4.2.3","ON 44 4418:1982"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Górnicze stalowe stropnice przegubowe Pomiar wymiarów Důlní ocelové stropnice kloubové Měření rozměrů PP-42.01.02, čl. 4.2.3 (ON 44 4418:1982) Gornicze stalowe stropnice przegubowe Pomiar wymiarow Dulni ocelove stropnice kloubove Mereni rozmeru PP-42.01.02, cl. 4.2.3 (ON 44 4418:1982)","search_en":"Articulated steel mine joists Measurement of dimensions PP-42.01.02, čl. 4.2.3 (ON 44 4418:1982)","search_zh":"矿用铰接钢顶梁 尺寸测量 PP-42.01.02, čl. 4.2.3 (ON 44 4418:1982)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"52d22b405c206680388286ba","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"77","test_object":"Sekcja obudowy zmechanizowanej","test_object_en":"Mechanised reinforcement section","test_object_zh":"液压支架段","test_object_cs":"Sekce mechanizované výztuže","methodology":"Badania obciążeniowe","methodology_en":"Load tests","methodology_zh":"负载试验","methodology_cs":"Zatěžovací zkoušky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badania obciążeniowe","reference":"CONSOL Inc./rev. 1994 - Sekce B","norm_bases":["CONSOL Inc./rev. 1994 - Sekce B"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sekcja obudowy zmechanizowanej Badania obciążeniowe Sekce mechanizované výztuže Zatěžovací zkoušky CONSOL Inc./rev. 1994 - Sekce B Sekcja obudowy zmechanizowanej Badania obciazeniowe Sekce mechanizovane vyztuze Zatezovaci zkousky CONSOL Inc./rev. 1994 - Sekce B","search_en":"Mechanised reinforcement section Load tests CONSOL Inc./rev. 1994 - Sekce B","search_zh":"液压支架段 负载试验 CONSOL Inc./rev. 1994 - Sekce B","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c5999bfaf69c42f0a2b81303","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"78","test_object":"Obudowa zmechanizowana","test_object_en":"Roof support","test_object_zh":"液压支架","test_object_cs":"Mechanizovaná výztuž","methodology":"Pomiar konstrukcyjny odkształcenia trwałego","methodology_en":"Design measurement of permanent deformation","methodology_zh":"永久变形结构测量","methodology_cs":"Konstrukční měření trvalé deformace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar konstrukcyjny odkształcenia trwałego","reference":"CONSOL Inc./rev. 1994 - Sekce C; ČSN EN 1804-1, příl. B; EN 1804-1, příl. B","norm_bases":["CONSOL Inc./rev. 1994 - Sekce C","ČSN EN 1804-1, příl. B","EN 1804-1, příl. B"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Obudowa zmechanizowana Pomiar konstrukcyjny odkształcenia trwałego Mechanizovaná výztuž Konstrukční měření trvalé deformace CONSOL Inc./rev. 1994 - Sekce C; ČSN EN 1804-1, příl. B; EN 1804-1, příl. B Obudowa zmechanizowana Pomiar konstrukcyjny odksztalcenia trwalego Mechanizovana vyztuz Konstrukcni mereni trvale deformace CONSOL Inc./rev. 1994 - Sekce C; CSN EN 1804-1, pril. B; EN 1804-1, pril. B","search_en":"Roof support Design measurement of permanent deformation CONSOL Inc./rev. 1994 - Sekce C; ČSN EN 1804-1, příl. B; EN 1804-1, příl. B","search_zh":"液压支架 永久变形结构测量 CONSOL Inc./rev. 1994 - Sekce C; ČSN EN 1804-1, příl. B; EN 1804-1, příl. B","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fb6d158820e5d64078ee5d7d","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"79","test_object":"Materiały metalowe","test_object_en":"Metallic materials","test_object_zh":"金属材料","test_object_cs":"Kovové materiály","methodology":"Próba udarności przy zginaniu wraz z przygotowaniem próbki","methodology_en":"Charpy pendulum impact test including sample preparation","methodology_zh":"摆锤冲击试验（含试样制备）","methodology_cs":"Zkouška rázem v ohybu včetně přípravy vzorku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba udarności przy zginaniu wraz z przygotowaniem próbki","reference":"ČSN ISO 148-1; ČSN EN ISO 377","norm_bases":["ČSN ISO 148-1","ČSN EN ISO 377"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiały metalowe Próba udarności przy zginaniu wraz z przygotowaniem próbki Kovové materiály Zkouška rázem v ohybu včetně přípravy vzorku ČSN ISO 148-1; ČSN EN ISO 377 Materialy metalowe Proba udarnosci przy zginaniu wraz z przygotowaniem probki Kovove materialy Zkouska razem v ohybu vcetne pripravy vzorku CSN ISO 148-1; CSN EN ISO 377","search_en":"Metallic materials Charpy pendulum impact test including sample preparation ČSN ISO 148-1; ČSN EN ISO 377","search_zh":"金属材料 摆锤冲击试验（含试样制备） ČSN ISO 148-1; ČSN EN ISO 377","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bf5af299510e7c6852fe226c","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"80","test_object":"Sekcja obudowy zmechanizowanej","test_object_en":"Mechanised reinforcement section","test_object_zh":"液压支架段","test_object_cs":"Sekce mechanizované výztuže","methodology":"Badania obciążeniowe","methodology_en":"Load tests","methodology_zh":"负载试验","methodology_cs":"Zatěžovací zkoušky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badania obciążeniowe","reference":"GOST 31561, čl. 13.1, 13.5, 13.11, 13.12, 13.13, 13.14, 13.15, 13.16, 13.17, 13.20, 13.21, 13.22","norm_bases":["GOST 31561, čl. 13.1, 13.5, 13.11, 13.12, 13.13, 13.14, 13.15, 13.16, 13.17, 13.20, 13.21, 13.22"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sekcja obudowy zmechanizowanej Badania obciążeniowe Sekce mechanizované výztuže Zatěžovací zkoušky GOST 31561, čl. 13.1, 13.5, 13.11, 13.12, 13.13, 13.14, 13.15, 13.16, 13.17, 13.20, 13.21, 13.22 Sekcja obudowy zmechanizowanej Badania obciazeniowe Sekce mechanizovane vyztuze Zatezovaci zkousky GOST 31561, cl. 13.1, 13.5, 13.11, 13.12, 13.13, 13.14, 13.15, 13.16, 13.17, 13.20, 13.21, 13.22","search_en":"Mechanised reinforcement section Load tests GOST 31561, čl. 13.1, 13.5, 13.11, 13.12, 13.13, 13.14, 13.15, 13.16, 13.17, 13.20, 13.21, 13.22","search_zh":"液压支架段 负载试验 GOST 31561, čl. 13.1, 13.5, 13.11, 13.12, 13.13, 13.14, 13.15, 13.16, 13.17, 13.20, 13.21, 13.22","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"557d5d9cc9fa689057759002","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"81","test_object":"Części i zespoły konstrukcyjne o charakterze mechanicznym i elektrotechnicznym","test_object_en":"Mechanical and electrotechnical parts and assemblies","test_object_zh":"机械和电工类结构零部件及总成","test_object_cs":"Konstrukční díly a celky strojírenského a elektrotechnického charakteru","methodology":"Badanie odporności na symulowane promieniowanie słoneczne","methodology_en":"Test for resistance to simulated solar radiation","methodology_zh":"耐模拟太阳辐射试验","methodology_cs":"Zkouška odolnosti vůči simulovanému slunečnímu záření","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na symulowane promieniowanie słoneczne","reference":"DIN 75220; PV 1211; PR 306.4; MIL-STD-810G, Meth. 505.5 Procedure II; VDA 230-219","norm_bases":["DIN 75220","PV 1211","PR 306.4","MIL-STD-810G, Meth. 505.5 Procedure II","VDA 230-219"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Części i zespoły konstrukcyjne o charakterze mechanicznym i elektrotechnicznym Badanie odporności na symulowane promieniowanie słoneczne Konstrukční díly a celky strojírenského a elektrotechnického charakteru Zkouška odolnosti vůči simulovanému slunečnímu záření DIN 75220; PV 1211; PR 306.4; MIL-STD-810G, Meth. 505.5 Procedure II; VDA 230-219 Czesci i zespoly konstrukcyjne o charakterze mechanicznym i elektrotechnicznym Badanie odpornosci na symulowane promieniowanie sloneczne Konstrukcni dily a celky strojirenskeho a elektrotechnickeho charakteru Zkouska odolnosti vuci simulovanemu slunecnimu zareni DIN 75220; PV 1211; PR 306.4; MIL-STD-810G, Meth. 505.5 Procedure II; VDA 230-219","search_en":"Mechanical and electrotechnical parts and assemblies Test for resistance to simulated solar radiation DIN 75220; PV 1211; PR 306.4; MIL-STD-810G, Meth. 505.5 Procedure II; VDA 230-219","search_zh":"机械和电工类结构零部件及总成 耐模拟太阳辐射试验 DIN 75220; PV 1211; PR 306.4; MIL-STD-810G, Meth. 505.5 Procedure II; VDA 230-219","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fb314da19f2a49cc41f4f3d6","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"82","test_object":"Części i zespoły konstrukcyjne o charakterze mechanicznym i elektrotechnicznym, powłoki i zabezpieczenia powierzchni","test_object_en":"Mechanical and electrotechnical parts and assemblies, surface coatings and protections","test_object_zh":"机械和电工类结构零部件及总成、表面处理和防护层","test_object_cs":"Konstrukční díly a celky strojírenského a elektrotechnického charakteru, povrchové úpravy a ochrany","methodology":"Badania wpływów środowiskowych","methodology_en":"Environmental testing","methodology_zh":"环境试验","methodology_cs":"Zkoušky vlivů prostředí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badania wpływów środowiskowych","reference":"ČSN EN 60068-2-1; ČSN EN 60068-2-2; ČSN EN 60068-2-14; ČSN EN 60068-2-67; ČSN EN 60068-2-78; PV 1200; PV 2005, varianta A; ČSN EN ISO 9227; čl. 5.2.2","norm_bases":["ČSN EN 60068-2-1","ČSN EN 60068-2-2","ČSN EN 60068-2-14","ČSN EN 60068-2-67","ČSN EN 60068-2-78","PV 1200","PV 2005, varianta A","ČSN EN ISO 9227; čl. 5.2.2"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Części i zespoły konstrukcyjne o charakterze mechanicznym i elektrotechnicznym, powłoki i zabezpieczenia powierzchni Badania wpływów środowiskowych Konstrukční díly a celky strojírenského a elektrotechnického charakteru, povrchové úpravy a ochrany Zkoušky vlivů prostředí ČSN EN 60068-2-1; ČSN EN 60068-2-2; ČSN EN 60068-2-14; ČSN EN 60068-2-67; ČSN EN 60068-2-78; PV 1200; PV 2005, varianta A; ČSN EN ISO 9227; čl. 5.2.2 Czesci i zespoly konstrukcyjne o charakterze mechanicznym i elektrotechnicznym, powloki i zabezpieczenia powierzchni Badania wplywow srodowiskowych Konstrukcni dily a celky strojirenskeho a elektrotechnickeho charakteru, povrchove upravy a ochrany Zkousky vlivu prostredi CSN EN 60068-2-1; CSN EN 60068-2-2; CSN EN 60068-2-14; CSN EN 60068-2-67; CSN EN 60068-2-78; PV 1200; PV 2005, varianta A; CSN EN ISO 9227; cl. 5.2.2","search_en":"Mechanical and electrotechnical parts and assemblies, surface coatings and protections Environmental testing ČSN EN 60068-2-1; ČSN EN 60068-2-2; ČSN EN 60068-2-14; ČSN EN 60068-2-67; ČSN EN 60068-2-78; PV 1200; PV 2005, varianta A; ČSN EN ISO 9227; čl. 5.2.2","search_zh":"机械和电工类结构零部件及总成、表面处理和防护层 环境试验 ČSN EN 60068-2-1; ČSN EN 60068-2-2; ČSN EN 60068-2-14; ČSN EN 60068-2-67; ČSN EN 60068-2-78; PV 1200; PV 2005, varianta A; ČSN EN ISO 9227; čl. 5.2.2","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"286bbad8a08611e62c71ffd3","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"83","test_object":"Farby i lakiery","test_object_en":"Paints and varnishes","test_object_zh":"涂料","test_object_cs":"Nátěrové hmoty","methodology":"Badania wpływów środowiskowych","methodology_en":"Environmental testing","methodology_zh":"环境试验","methodology_cs":"Zkoušky vlivů prostředí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badania wpływów środowiskowych","reference":"ČSN EN ISO 6270-2; ČSN EN ISO 11997-1, Příloha A, B","norm_bases":["ČSN EN ISO 6270-2","ČSN EN ISO 11997-1, Příloha A, B"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Farby i lakiery Badania wpływów środowiskowych Nátěrové hmoty Zkoušky vlivů prostředí ČSN EN ISO 6270-2; ČSN EN ISO 11997-1, Příloha A, B Farby i lakiery Badania wplywow srodowiskowych Naterove hmoty Zkousky vlivu prostredi CSN EN ISO 6270-2; CSN EN ISO 11997-1, Priloha A, B","search_en":"Paints and varnishes Environmental testing ČSN EN ISO 6270-2; ČSN EN ISO 11997-1, Příloha A, B","search_zh":"涂料 环境试验 ČSN EN ISO 6270-2; ČSN EN ISO 11997-1, Příloha A, B","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9daee2a532982dd61ec1d181","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"84","test_object":"Farby i lakiery oraz powłoki organiczne, powłoki metalowe i inne nieorganiczne","test_object_en":"Paints and varnishes and organic coatings, metallic and other inorganic coatings","test_object_zh":"涂料和有机涂层、金属及其他无机涂层","test_object_cs":"Nátěrové hmoty a organické povlaky, kovové a jiné anorganické povlaky","methodology":"Ocena stopnia zniszczenia","methodology_en":"Damage rating test","methodology_zh":"损坏程度评定试验","methodology_cs":"Zkouška stanovení stupně poškození","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ocena stopnia zniszczenia","reference":"ČSN EN ISO 4628-1; ČSN EN ISO 4628-2; ČSN EN ISO 4628-3; ČSN EN ISO 4628-4; ČSN EN ISO 4628-5; ČSN EN ISO 4628-6; ČSN EN ISO 4628-8; ČSN EN ISO 4628-10","norm_bases":["ČSN EN ISO 4628-1","ČSN EN ISO 4628-2","ČSN EN ISO 4628-3","ČSN EN ISO 4628-4","ČSN EN ISO 4628-5","ČSN EN ISO 4628-6","ČSN EN ISO 4628-8","ČSN EN ISO 4628-10"],"lab_section":"oddział Opava","lab_section_en":"Workplace Opava","lab_section_zh":"奥帕瓦工作场所","lab_section_cs":"pracoviště Opava","lab_address":"Těšínská 2962/79b, Předměstí, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Farby i lakiery oraz powłoki organiczne, powłoki metalowe i inne nieorganiczne Ocena stopnia zniszczenia Nátěrové hmoty a organické povlaky, kovové a jiné anorganické povlaky Zkouška stanovení stupně poškození ČSN EN ISO 4628-1; ČSN EN ISO 4628-2; ČSN EN ISO 4628-3; ČSN EN ISO 4628-4; ČSN EN ISO 4628-5; ČSN EN ISO 4628-6; ČSN EN ISO 4628-8; ČSN EN ISO 4628-10 Farby i lakiery oraz powloki organiczne, powloki metalowe i inne nieorganiczne Ocena stopnia zniszczenia Naterove hmoty a organicke povlaky, kovove a jine anorganicke povlaky Zkouska stanoveni stupne poskozeni CSN EN ISO 4628-1; CSN EN ISO 4628-2; CSN EN ISO 4628-3; CSN EN ISO 4628-4; CSN EN ISO 4628-5; CSN EN ISO 4628-6; CSN EN ISO 4628-8; CSN EN ISO 4628-10","search_en":"Paints and varnishes and organic coatings, metallic and other inorganic coatings Damage rating test ČSN EN ISO 4628-1; ČSN EN ISO 4628-2; ČSN EN ISO 4628-3; ČSN EN ISO 4628-4; ČSN EN ISO 4628-5; ČSN EN ISO 4628-6; ČSN EN ISO 4628-8; ČSN EN ISO 4628-10","search_zh":"涂料和有机涂层、金属及其他无机涂层 损坏程度评定试验 ČSN EN ISO 4628-1; ČSN EN ISO 4628-2; ČSN EN ISO 4628-3; ČSN EN ISO 4628-4; ČSN EN ISO 4628-5; ČSN EN ISO 4628-6; ČSN EN ISO 4628-8; ČSN EN ISO 4628-10","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8c33393508658e2ee457d919","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"1","test_object":"Części i zespoły konstrukcyjne o charakterze mechanicznym i elektrotechnicznym, powłoki i zabezpieczenia powierzchni","test_object_en":"Mechanical and electrotechnical parts and assemblies, surface coatings and protections","test_object_zh":"机械和电工类结构零部件及总成、表面处理和防护层","test_object_cs":"Konstrukční díly a celky strojírenského a elektrotechnického charakteru, povrchové úpravy a ochrany","methodology":"Badania wpływów środowiskowych","methodology_en":"Environmental testing","methodology_zh":"环境试验","methodology_cs":"Zkoušky vlivů prostředí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badania wpływów środowiskowych","reference":"ČSN EN 60068-2-1; ČSN EN 60068-2-2; ČSN EN IEC 60068-2-11; ČSN EN 60068-2-14; ČSN EN 60068-2-30; ČSN EN IEC 60068-2-52; ČSN EN 60068-2-67; ČSN EN 60068-2-78; ČSN EN ISO 9227; LV 124, bod 9.1, K-01; LV 124, bod 9.2, K-02; LV 124, bod 9.3, K-03; LV 124, bod 9.4, K-04; LV 124, bod 9.6, K-06; LV 124, bod 9.7, K-07; LV 124, bod 9.8, K-08; LV 124, bod 9.9, K-09; LV 124, bod 9.14, K-014","norm_bases":["ČSN EN 60068-2-1","ČSN EN 60068-2-2","ČSN EN IEC 60068-2-11","ČSN EN 60068-2-14","ČSN EN 60068-2-30","ČSN EN IEC 60068-2-52","ČSN EN 60068-2-67","ČSN EN 60068-2-78","ČSN EN ISO 9227","LV 124, bod 9.1, K-01","LV 124, bod 9.2, K-02","LV 124, bod 9.3, K-03","LV 124, bod 9.4, K-04","LV 124, bod 9.6, K-06","LV 124, bod 9.7, K-07","LV 124, bod 9.8, K-08","LV 124, bod 9.9, K-09","LV 124, bod 9.14, K-014"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Części i zespoły konstrukcyjne o charakterze mechanicznym i elektrotechnicznym, powłoki i zabezpieczenia powierzchni Badania wpływów środowiskowych Konstrukční díly a celky strojírenského a elektrotechnického charakteru, povrchové úpravy a ochrany Zkoušky vlivů prostředí ČSN EN 60068-2-1; ČSN EN 60068-2-2; ČSN EN IEC 60068-2-11; ČSN EN 60068-2-14; ČSN EN 60068-2-30; ČSN EN IEC 60068-2-52; ČSN EN 60068-2-67; ČSN EN 60068-2-78; ČSN EN ISO 9227; LV 124, bod 9.1, K-01; LV 124, bod 9.2, K-02; LV 124, bod 9.3, K-03; LV 124, bod 9.4, K-04; LV 124, bod 9.6, K-06; LV 124, bod 9.7, K-07; LV 124, bod 9.8, K-08; LV 124, bod 9.9, K-09; LV 124, bod 9.14, K-014 Czesci i zespoly konstrukcyjne o charakterze mechanicznym i elektrotechnicznym, powloki i zabezpieczenia powierzchni Badania wplywow srodowiskowych Konstrukcni dily a celky strojirenskeho a elektrotechnickeho charakteru, povrchove upravy a ochrany Zkousky vlivu prostredi CSN EN 60068-2-1; CSN EN 60068-2-2; CSN EN IEC 60068-2-11; CSN EN 60068-2-14; CSN EN 60068-2-30; CSN EN IEC 60068-2-52; CSN EN 60068-2-67; CSN EN 60068-2-78; CSN EN ISO 9227; LV 124, bod 9.1, K-01; LV 124, bod 9.2, K-02; LV 124, bod 9.3, K-03; LV 124, bod 9.4, K-04; LV 124, bod 9.6, K-06; LV 124, bod 9.7, K-07; LV 124, bod 9.8, K-08; LV 124, bod 9.9, K-09; LV 124, bod 9.14, K-014","search_en":"Mechanical and electrotechnical parts and assemblies, surface coatings and protections Environmental testing ČSN EN 60068-2-1; ČSN EN 60068-2-2; ČSN EN IEC 60068-2-11; ČSN EN 60068-2-14; ČSN EN 60068-2-30; ČSN EN IEC 60068-2-52; ČSN EN 60068-2-67; ČSN EN 60068-2-78; ČSN EN ISO 9227; LV 124, bod 9.1, K-01; LV 124, bod 9.2, K-02; LV 124, bod 9.3, K-03; LV 124, bod 9.4, K-04; LV 124, bod 9.6, K-06; LV 124, bod 9.7, K-07; LV 124, bod 9.8, K-08; LV 124, bod 9.9, K-09; LV 124, bod 9.14, K-014","search_zh":"机械和电工类结构零部件及总成、表面处理和防护层 环境试验 ČSN EN 60068-2-1; ČSN EN 60068-2-2; ČSN EN IEC 60068-2-11; ČSN EN 60068-2-14; ČSN EN 60068-2-30; ČSN EN IEC 60068-2-52; ČSN EN 60068-2-67; ČSN EN 60068-2-78; ČSN EN ISO 9227; LV 124, bod 9.1, K-01; LV 124, bod 9.2, K-02; LV 124, bod 9.3, K-03; LV 124, bod 9.4, K-04; LV 124, bod 9.6, K-06; LV 124, bod 9.7, K-07; LV 124, bod 9.8, K-08; LV 124, bod 9.9, K-09; LV 124, bod 9.14, K-014","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b66693cb09177b533f66731f","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"2","test_object":"Części pojazdów drogowych","test_object_en":"Road vehicle components","test_object_zh":"道路车辆零部件","test_object_cs":"Díly silničních vozidel","methodology":"Badania wpływów środowiskowych","methodology_en":"Environmental testing","methodology_zh":"环境试验","methodology_cs":"Zkoušky vlivů prostředí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badania wpływów środowiskowych","reference":"PV 1200; PV 1209; PV 1210; PV 2005, varianta A; GMW 3286; GMW 14124, cyklus M","norm_bases":["PV 1200","PV 1209","PV 1210","PV 2005, varianta A","GMW 3286","GMW 14124, cyklus M"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Części pojazdów drogowych Badania wpływów środowiskowych Díly silničních vozidel Zkoušky vlivů prostředí PV 1200; PV 1209; PV 1210; PV 2005, varianta A; GMW 3286; GMW 14124, cyklus M Czesci pojazdow drogowych Badania wplywow srodowiskowych Dily silnicnich vozidel Zkousky vlivu prostredi PV 1200; PV 1209; PV 1210; PV 2005, varianta A; GMW 3286; GMW 14124, cyklus M","search_en":"Road vehicle components Environmental testing PV 1200; PV 1209; PV 1210; PV 2005, varianta A; GMW 3286; GMW 14124, cyklus M","search_zh":"道路车辆零部件 环境试验 PV 1200; PV 1209; PV 1210; PV 2005, varianta A; GMW 3286; GMW 14124, cyklus M","categories":["automotive"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4510eab8f30c1f64334f492b","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"3","test_object":"Farby i lakiery","test_object_en":"Paints and varnishes","test_object_zh":"涂料","test_object_cs":"Nátěrové hmoty","methodology":"Badania wpływów środowiskowych","methodology_en":"Environmental testing","methodology_zh":"环境试验","methodology_cs":"Zkoušky vlivů prostředí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badania wpływów środowiskowych","reference":"ČSN EN ISO 6270-2; ČSN EN ISO 11997-1, Příloha A, B; Qualicoat bod. 2.4.2.; Qualicoat bod. 2.11","norm_bases":["ČSN EN ISO 6270-2","ČSN EN ISO 11997-1, Příloha A, B","Qualicoat bod. 2.4.2.","Qualicoat bod. 2.11"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Farby i lakiery Badania wpływów środowiskowych Nátěrové hmoty Zkoušky vlivů prostředí ČSN EN ISO 6270-2; ČSN EN ISO 11997-1, Příloha A, B; Qualicoat bod. 2.4.2.; Qualicoat bod. 2.11 Farby i lakiery Badania wplywow srodowiskowych Naterove hmoty Zkousky vlivu prostredi CSN EN ISO 6270-2; CSN EN ISO 11997-1, Priloha A, B; Qualicoat bod. 2.4.2.; Qualicoat bod. 2.11","search_en":"Paints and varnishes Environmental testing ČSN EN ISO 6270-2; ČSN EN ISO 11997-1, Příloha A, B; Qualicoat bod. 2.4.2.; Qualicoat bod. 2.11","search_zh":"涂料 环境试验 ČSN EN ISO 6270-2; ČSN EN ISO 11997-1, Příloha A, B; Qualicoat bod. 2.4.2.; Qualicoat bod. 2.11","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"531cd9f94f0e74ff009f1a06","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"4","test_object":"Korozja metali i stopów","test_object_en":"Corrosion of metals and alloys","test_object_zh":"金属和合金腐蚀","test_object_cs":"Koroze kovů a slitin","methodology":"Badania wpływów środowiskowych","methodology_en":"Environmental testing","methodology_zh":"环境试验","methodology_cs":"Zkoušky vlivů prostředí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badania wpływów środowiskowych","reference":"ČSN EN ISO 16701","norm_bases":["ČSN EN ISO 16701"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Korozja metali i stopów Badania wpływów środowiskowych Koroze kovů a slitin Zkoušky vlivů prostředí ČSN EN ISO 16701 Korozja metali i stopow Badania wplywow srodowiskowych Koroze kovu a slitin Zkousky vlivu prostredi CSN EN ISO 16701","search_en":"Corrosion of metals and alloys Environmental testing ČSN EN ISO 16701","search_zh":"金属和合金腐蚀 环境试验 ČSN EN ISO 16701","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":82,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dc4dc1da858b36e71c39396a","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"6","test_object":"Właściwości mechaniczne przedmiotu","test_object_en":"Mechanical properties of the object","test_object_zh":"物体的机械性能","test_object_cs":"Mechanické vlastnosti předmětu","methodology":"Próba swobodnego spadku","methodology_en":"Free fall test","methodology_zh":"自由跌落试验","methodology_cs":"Zkouška volným pádem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba swobodnego spadku","reference":"LV 124, bod 8.1, M-01","norm_bases":["LV 124, bod 8.1, M-01"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Właściwości mechaniczne przedmiotu Próba swobodnego spadku Mechanické vlastnosti předmětu Zkouška volným pádem LV 124, bod 8.1, M-01 Wlasciwosci mechaniczne przedmiotu Proba swobodnego spadku Mechanicke vlastnosti predmetu Zkouska volnym padem LV 124, bod 8.1, M-01","search_en":"Mechanical properties of the object Free fall test LV 124, bod 8.1, M-01","search_zh":"物体的机械性能 自由跌落试验 LV 124, bod 8.1, M-01","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":83,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a2417e8b0cd1e7a45e316451","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"7","test_object":"Części i zespoły konstrukcyjne o charakterze mechanicznym i elektrotechnicznym","test_object_en":"Mechanical and electrotechnical parts and assemblies","test_object_zh":"机械和电工类结构零部件及总成","test_object_cs":"Konstrukční díly a celky strojírenského a elektrotechnického charakteru","methodology":"Badania trwałości cyklicznej – obciążenie temperaturowe","methodology_en":"Cyclic life tests – temperature loading","methodology_zh":"循环寿命试验–温度加载","methodology_cs":"Zkoušky cyklické životnosti – teplotní zatěžování","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badania trwałości cyklicznej – obciążenie temperaturowe","reference":"LV 124, bod 11.1, L-01; LV 124, bod 11.2, L-02; LV 124, bod 11.3, L-03","norm_bases":["LV 124, bod 11.1, L-01","LV 124, bod 11.2, L-02","LV 124, bod 11.3, L-03"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Części i zespoły konstrukcyjne o charakterze mechanicznym i elektrotechnicznym Badania trwałości cyklicznej – obciążenie temperaturowe Konstrukční díly a celky strojírenského a elektrotechnického charakteru Zkoušky cyklické životnosti – teplotní zatěžování LV 124, bod 11.1, L-01; LV 124, bod 11.2, L-02; LV 124, bod 11.3, L-03 Czesci i zespoly konstrukcyjne o charakterze mechanicznym i elektrotechnicznym Badania trwalosci cyklicznej – obciazenie temperaturowe Konstrukcni dily a celky strojirenskeho a elektrotechnickeho charakteru Zkousky cyklicke zivotnosti – teplotni zatezovani LV 124, bod 11.1, L-01; LV 124, bod 11.2, L-02; LV 124, bod 11.3, L-03","search_en":"Mechanical and electrotechnical parts and assemblies Cyclic life tests – temperature loading LV 124, bod 11.1, L-01; LV 124, bod 11.2, L-02; LV 124, bod 11.3, L-03","search_zh":"机械和电工类结构零部件及总成 循环寿命试验–温度加载 LV 124, bod 11.1, L-01; LV 124, bod 11.2, L-02; LV 124, bod 11.3, L-03","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":84,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3a66a120406f0a20d038f9bf","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"8","test_object":"Powłoki metalowe i inne nieorganiczne","test_object_en":"Metallic and other inorganic coatings","test_object_zh":"金属及其他无机涂层","test_object_cs":"Kovové a jiné anorganické povlaky","methodology":"Ocena stopnia zniszczenia","methodology_en":"Damage rating test","methodology_zh":"损坏程度评定试验","methodology_cs":"Zkouška stanovení stupně poškození","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ocena stopnia zniszczenia","reference":"ČSN EN ISO 10289","norm_bases":["ČSN EN ISO 10289"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powłoki metalowe i inne nieorganiczne Ocena stopnia zniszczenia Kovové a jiné anorganické povlaky Zkouška stanovení stupně poškození ČSN EN ISO 10289 Powloki metalowe i inne nieorganiczne Ocena stopnia zniszczenia Kovove a jine anorganicke povlaky Zkouska stanoveni stupne poskozeni CSN EN ISO 10289","search_en":"Metallic and other inorganic coatings Damage rating test ČSN EN ISO 10289","search_zh":"金属及其他无机涂层 损坏程度评定试验 ČSN EN ISO 10289","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":85,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eea86761ec311ddc068b7b7d","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"9","test_object":"Farby i lakiery","test_object_en":"Coatings","test_object_zh":"涂料","test_object_cs":"Nátěrové hmoty","methodology":"Oznaczanie grubości","methodology_en":"Determination of thickness","methodology_zh":"厚度测定","methodology_cs":"Stanovení tloušťky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie grubości","reference":"ČSN EN ISO 2808, met 7C;","norm_bases":["ČSN EN ISO 2808, met 7C"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Farby i lakiery Oznaczanie grubości Nátěrové hmoty Stanovení tloušťky ČSN EN ISO 2808, met 7C; Farby i lakiery Oznaczanie grubosci Naterove hmoty Stanoveni tloustky CSN EN ISO 2808, met 7C;","search_en":"Coatings Determination of thickness ČSN EN ISO 2808, met 7C;","search_zh":"涂料 厚度测定 ČSN EN ISO 2808, met 7C;","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":86,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7a13a8a77bc651298cb441a1","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"10","test_object":"Powłoki ochronne, nieorganiczne, metalowe i inne","test_object_en":"Protective coatings, inorganic, metallic and other coatings","test_object_zh":"防护涂层、无机涂层、金属及其他涂层","test_object_cs":"Ochranné povlaky, anorganické, kovové a jiné povlaky","methodology":"Oznaczanie grubości","methodology_en":"Determination of thickness","methodology_zh":"厚度测定","methodology_cs":"Stanovení tloušťky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie grubości","reference":"ČSN EN ISO 2178; bod 4.4","norm_bases":["ČSN EN ISO 2178; bod 4.4"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powłoki ochronne, nieorganiczne, metalowe i inne Oznaczanie grubości Ochranné povlaky, anorganické, kovové a jiné povlaky Stanovení tloušťky ČSN EN ISO 2178; bod 4.4 Powloki ochronne, nieorganiczne, metalowe i inne Oznaczanie grubosci Ochranne povlaky, anorganicke, kovove a jine povlaky Stanoveni tloustky CSN EN ISO 2178; bod 4.4","search_en":"Protective coatings, inorganic, metallic and other coatings Determination of thickness ČSN EN ISO 2178; bod 4.4","search_zh":"防护涂层、无机涂层、金属及其他涂层 厚度测定 ČSN EN ISO 2178; bod 4.4","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":87,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7718b101ce32febeb66b4369","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"11","test_object":"Farby i lakiery oraz powłoki organiczne, powłoki metalowe i inne nieorganiczne","test_object_en":"Paints and varnishes and organic coatings; metallic and other inorganic coatings","test_object_zh":"涂料和有机涂层、金属及其他无机涂层","test_object_cs":"Nátěrové hmoty a organické povlaky, kovové a jiné anorganické povlaky","methodology":"Ocena stopnia zniszczenia","methodology_en":"Determination of the degree of degradation","methodology_zh":"损坏程度评定试验","methodology_cs":"Zkouška stanovení stupně poškození","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ocena stopnia zniszczenia","reference":"ČSN EN ISO 4628-1; ČSN EN ISO 4628-2; ČSN EN ISO 4628-3; ČSN EN ISO 4628-4; ČSN EN ISO 4628-5; ČSN EN ISO 4628-6; ČSN EN ISO 4628-8; ČSN EN ISO 4628-10","norm_bases":["ČSN EN ISO 4628-1","ČSN EN ISO 4628-2","ČSN EN ISO 4628-3","ČSN EN ISO 4628-4","ČSN EN ISO 4628-5","ČSN EN ISO 4628-6","ČSN EN ISO 4628-8","ČSN EN ISO 4628-10"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Farby i lakiery oraz powłoki organiczne, powłoki metalowe i inne nieorganiczne Ocena stopnia zniszczenia Nátěrové hmoty a organické povlaky, kovové a jiné anorganické povlaky Zkouška stanovení stupně poškození ČSN EN ISO 4628-1; ČSN EN ISO 4628-2; ČSN EN ISO 4628-3; ČSN EN ISO 4628-4; ČSN EN ISO 4628-5; ČSN EN ISO 4628-6; ČSN EN ISO 4628-8; ČSN EN ISO 4628-10 Farby i lakiery oraz powloki organiczne, powloki metalowe i inne nieorganiczne Ocena stopnia zniszczenia Naterove hmoty a organicke povlaky, kovove a jine anorganicke povlaky Zkouska stanoveni stupne poskozeni CSN EN ISO 4628-1; CSN EN ISO 4628-2; CSN EN ISO 4628-3; CSN EN ISO 4628-4; CSN EN ISO 4628-5; CSN EN ISO 4628-6; CSN EN ISO 4628-8; CSN EN ISO 4628-10","search_en":"Paints and varnishes and organic coatings; metallic and other inorganic coatings Determination of the degree of degradation ČSN EN ISO 4628-1; ČSN EN ISO 4628-2; ČSN EN ISO 4628-3; ČSN EN ISO 4628-4; ČSN EN ISO 4628-5; ČSN EN ISO 4628-6; ČSN EN ISO 4628-8; ČSN EN ISO 4628-10","search_zh":"涂料和有机涂层、金属及其他无机涂层 损坏程度评定试验 ČSN EN ISO 4628-1; ČSN EN ISO 4628-2; ČSN EN ISO 4628-3; ČSN EN ISO 4628-4; ČSN EN ISO 4628-5; ČSN EN ISO 4628-6; ČSN EN ISO 4628-8; ČSN EN ISO 4628-10","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":88,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ff51d92ac6f2f00a8d33cd34","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"12","test_object":"Farby i lakiery","test_object_en":"Paints and varnishes","test_object_zh":"涂料","test_object_cs":"Nátěrové hmoty","methodology":"Próba siatki nacięć","methodology_en":"Cross-cut test","methodology_zh":"划格试验","methodology_cs":"Mřížková zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba siatki nacięć","reference":"ČSN EN ISO 2409","norm_bases":["ČSN EN ISO 2409"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Farby i lakiery Próba siatki nacięć Nátěrové hmoty Mřížková zkouška ČSN EN ISO 2409 Farby i lakiery Proba siatki naciec Naterove hmoty Mrizkova zkouska CSN EN ISO 2409","search_en":"Paints and varnishes Cross-cut test ČSN EN ISO 2409","search_zh":"涂料 划格试验 ČSN EN ISO 2409","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":89,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"231116029461ce04a39e5270","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"13","test_object":"Farby i lakiery","test_object_en":"Paints and varnishes","test_object_zh":"涂料","test_object_cs":"Nátěrové hmoty","methodology":"Próba szybkiego odkształcenia (odporność na uderzenie)","methodology_en":"Rapid deformation test (impact resistance)","methodology_zh":"快速变形试验（抗冲击性）","methodology_cs":"Zkouška rychlou deformací (odolnost proti úderu)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba szybkiego odkształcenia (odporność na uderzenie)","reference":"ASTM D 2794","norm_bases":["ASTM D 2794"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Farby i lakiery Próba szybkiego odkształcenia (odporność na uderzenie) Nátěrové hmoty Zkouška rychlou deformací (odolnost proti úderu) ASTM D 2794 Farby i lakiery Proba szybkiego odksztalcenia (odpornosc na uderzenie) Naterove hmoty Zkouska rychlou deformaci (odolnost proti uderu) ASTM D 2794","search_en":"Paints and varnishes Rapid deformation test (impact resistance) ASTM D 2794","search_zh":"涂料 快速变形试验（抗冲击性） ASTM D 2794","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":90,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7106044ef7002c0f9302380f","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"14","test_object":"Farby i lakiery bez pigmentów metalicznych","test_object_en":"Paints and varnishes","test_object_zh":"不含金属颜料的涂料","test_object_cs":"Nátěrové hmoty bez obsahu kovových pigmentů","methodology":"Oznaczanie połysku zwierciadlanego powłok pod kątem 60°","methodology_en":"Determination of gloss value at 60° without metal pigments","methodology_zh":"涂层60°镜面光泽度测定","methodology_cs":"Stanovení zrcadlového lesku nátěrů při úhlu 60°","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie połysku zwierciadlanego powłok pod kątem 60°","reference":"ČSN EN ISO 2813","norm_bases":["ČSN EN ISO 2813"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Farby i lakiery bez pigmentów metalicznych Oznaczanie połysku zwierciadlanego powłok pod kątem 60° Nátěrové hmoty bez obsahu kovových pigmentů Stanovení zrcadlového lesku nátěrů při úhlu 60° ČSN EN ISO 2813 Farby i lakiery bez pigmentow metalicznych Oznaczanie polysku zwierciadlanego powlok pod katem 60° Naterove hmoty bez obsahu kovovych pigmentu Stanoveni zrcadloveho lesku nateru pri uhlu 60° CSN EN ISO 2813","search_en":"Paints and varnishes Determination of gloss value at 60° without metal pigments ČSN EN ISO 2813","search_zh":"不含金属颜料的涂料 涂层60°镜面光泽度测定 ČSN EN ISO 2813","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":91,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"171d97947717c9b2f89cd190","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"15","test_object":"Farby i lakiery","test_object_en":"Paints and varnishes","test_object_zh":"涂料","test_object_cs":"Nátěrové hmoty","methodology":"Badanie odporności na pękanie przy tłoczeniu","methodology_en":"Cupping test of resistance to cracking","methodology_zh":"杯突抗开裂试验","methodology_cs":"Zkouška odolnosti vůči praskání hloubením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na pękanie przy tłoczeniu","reference":"ČSN EN ISO 1520","norm_bases":["ČSN EN ISO 1520"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Farby i lakiery Badanie odporności na pękanie przy tłoczeniu Nátěrové hmoty Zkouška odolnosti vůči praskání hloubením ČSN EN ISO 1520 Farby i lakiery Badanie odpornosci na pekanie przy tloczeniu Naterove hmoty Zkouska odolnosti vuci praskani hloubenim CSN EN ISO 1520","search_en":"Paints and varnishes Cupping test of resistance to cracking ČSN EN ISO 1520","search_zh":"涂料 杯突抗开裂试验 ČSN EN ISO 1520","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":92,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e774de83a405a451463200ec","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"16","test_object":"Farby i lakiery","test_object_en":"Paints and varnishes","test_object_zh":"涂料","test_object_cs":"Nátěrové hmoty","methodology":"Próba zginania (na trzpieniu walcowym)","methodology_en":"Bend test (cylindrical mandrel)","methodology_zh":"弯曲试验（圆柱轴）","methodology_cs":"Zkouška ohybem (na válcovém trnu)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Próba zginania (na trzpieniu walcowym)","reference":"ČSN EN ISO 1519","norm_bases":["ČSN EN ISO 1519"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Farby i lakiery Próba zginania (na trzpieniu walcowym) Nátěrové hmoty Zkouška ohybem (na válcovém trnu) ČSN EN ISO 1519 Farby i lakiery Proba zginania (na trzpieniu walcowym) Naterove hmoty Zkouska ohybem (na valcovem trnu) CSN EN ISO 1519","search_en":"Paints and varnishes Bend test (cylindrical mandrel) ČSN EN ISO 1519","search_zh":"涂料 弯曲试验（圆柱轴） ČSN EN ISO 1519","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":93,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"66ab88abc2283da6bfb7232a","lab_id":"69ad52a4de79e566650fd37c","country":"CZ","accr_number":"1322","accr_body":"ČIA","row_label":"17","test_object":"Farby i lakiery","test_object_en":"Paints and varnishes","test_object_zh":"涂料","test_object_cs":"Nátěrové hmoty","methodology":"Oznaczanie odporności na korozję nitkową","methodology_en":"Determination of resistance to filiform corrosion","methodology_zh":"耐丝状腐蚀测定","methodology_cs":"Stanovení odolnosti proti nitkové korozi","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności na korozję nitkową","reference":"ČSN EN ISO 4623-2","norm_bases":["ČSN EN ISO 4623-2"],"lab_section":"oddział Čermná ve Slezsku","lab_section_en":"Workplace Čermná ve Slezsku","lab_section_zh":"Čermná ve Slezsku工作场所","lab_section_cs":"pracoviště Čermná ve Slezsku","lab_address":"Čermná ve Slezsku 100, 749 01 Čermná ve Slezsku","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Farby i lakiery Oznaczanie odporności na korozję nitkową Nátěrové hmoty Stanovení odolnosti proti nitkové korozi ČSN EN ISO 4623-2 Farby i lakiery Oznaczanie odpornosci na korozje nitkowa Naterove hmoty Stanoveni odolnosti proti nitkove korozi CSN EN ISO 4623-2","search_en":"Paints and varnishes Determination of resistance to filiform corrosion ČSN EN ISO 4623-2","search_zh":"涂料 耐丝状腐蚀测定 ČSN EN ISO 4623-2","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":94,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}