{"lab":{"_id":"69ad52a4de79e566650fd35e","accr_number":"1306","country":"CZ","accr_body":"ČIA","address":"Pod Vinicí 83, 471 27 Stráž pod Ralskem","categories":["water"],"city":"Stráž pod Ralskem","imported_at":"2026-03-08T10:42:44.590Z","methods_count":22,"name":"DIAMO, státní podnik, odštěpný závod Stráž","parse_status":"parsed","parse_version":5,"pdf_files":["1306_275_2025_CS.pdf","1306_275_2025_EN.pdf"],"scope_summary":"Analiza chemiczna i radiochemiczna wód powierzchniowych, opadowych, z osadników, kopalnianych i ścieków oraz resztkowych roztworów technologicznych, pobieranie próbek ścieków, w zakresie określonym w załączniku do świadectwa.","search_text":"diamo, státní podnik, odštěpný závod stráž pod vinicí 83, 471 27 stráž pod ralskem 1306","status":"active","updated_at":"2026-03-08T14:52:09.970Z","valid_from":"","valid_until":"19-02-2029","website":"www.diamo.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.diamo.cz/kontakty","map_coord":[50.696008,14.77791],"map_geo":"nominatim-street","certificate_date":"06.06.2025","certificate_no":"275/2025","certificate_replaces":"482/2024 z 16.09.2024","en_official":false,"fields_of_testing":[{"codes":"","pl":"Analiza chemiczna i radiochemiczna wód powierzchniowych, opadowych, z osadników, kopalnianych i ścieków oraz resztkowych roztworów technologicznych, pobieranie próbek ścieków, w zakresie określonym w załączniku do świadectwa.","en":"Chemical and radiochemical analysis of surface, precipitation, tailings pond, mine and waste waters and residual technological solutions, sampling of waste waters, as specified in the appendix to this certificate.","zh":"地表水、降水、尾矿库水、矿井水、废水及残余工艺溶液的化学和放射化学分析，废水采样，范围见本证书附件。","cs":"Chemický a radiochemický rozbor povrchových, srážkových, odkalištních, důlních a odpadních vod a zbytkových technologických roztoků, vzorkování odpadních vod, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Ośrodek Laboratoriów – laboratorium badawcze","lab_division_cs":"Středisko laboratoří – zkušební laboratoř","lab_division_en":"Laboratory Centre – Testing Laboratory","lab_division_zh":"实验室中心 – 检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The laboratory is qualified to carry out standalone sampling.","zh":"实验室有能力独立开展采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."}],"source_lang":"cs","source_pdf_sha256":"1cd71cdb84fdb8d810e9eabc31f6d38342cdf45e71d977c79365c5b6053d384c","source_pdf_url":"https://www.cai.cz/OA/pdf/275_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"72985caf6888257fa75023a6","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"1","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie pH","methodology_en":"Determination of pH","methodology_zh":"pH测定","methodology_cs":"Stanovení pH","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda potencjometryczna","technique_en":"Potentiometry","technique_zh":"电位法","technique_cs":"potenciometricky","techniques":["Metoda potencjometryczna"],"techniques_en":["Potentiometry"],"techniques_zh":["电位法"],"techniques_cs":["potenciometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH\nMetoda potencjometryczna","reference":"PP-ST-SL-01-02 (ČSN ISO 10523)","norm_bases":["PP-ST-SL-01-02","ČSN ISO 10523"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie pH Metoda potencjometryczna Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení pH potenciometricky PP-ST-SL-01-02 (ČSN ISO 10523) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie pH Metoda potencjometryczna Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni pH potenciometricky PP-ST-SL-01-02 (CSN ISO 10523)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of pH Potentiometry PP-ST-SL-01-02 (ČSN ISO 10523)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 pH测定 电位法 PP-ST-SL-01-02 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"562c4713517eac233070a9a0","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"2","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie przewodności elektrycznej właściwej","methodology_en":"Determination of electrical conductivity","methodology_zh":"电导率测定","methodology_cs":"Stanovení elektrické konduktivity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej właściwej","reference":"PP-ST-SL-02-02 (ČSN EN 27888)","norm_bases":["PP-ST-SL-02-02","ČSN EN 27888"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie przewodności elektrycznej właściwej Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení elektrické konduktivity PP-ST-SL-02-02 (ČSN EN 27888) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie przewodnosci elektrycznej wlasciwej Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni elektricke konduktivity PP-ST-SL-02-02 (CSN EN 27888)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of electrical conductivity PP-ST-SL-02-02 (ČSN EN 27888)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 电导率测定 PP-ST-SL-02-02 (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a06012df0154fedf9e94c300","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"3","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie zasadowości – kwasowej pojemności neutralizacyjnej (KNK4,5; KNK8,3)","methodology_en":"Determination of acid neutralizing capacity (alkalinity) (KNK4.5; KNK8.3)","methodology_zh":"酸中和能力（碱度）测定（KNK4.5；KNK8.3）","methodology_cs":"Stanovení kyselinové neutralizační kapacity (KNK4,5; KNK8,3)","parameters":[{"name":"KNK4,5 (do pH 4,5)","range":""},{"name":"KNK8,3 (do pH 8,3)","range":""}],"parameters_en":[{"name":"KNK4.5 (to pH 4.5)","range":""},{"name":"KNK8.3 (to pH 8.3)","range":""}],"parameters_zh":[{"name":"KNK4.5（至pH 4.5）","range":""},{"name":"KNK8.3（至pH 8.3）","range":""}],"parameters_cs":[{"name":"KNK4,5","range":""},{"name":"KNK8,3","range":""}],"technique":"Metoda miareczkowania potencjometrycznego","technique_en":"Potentiometric titration","technique_zh":"电位滴定法","technique_cs":"potenciometrickou titrací","techniques":["Metoda miareczkowania potencjometrycznego"],"techniques_en":["Potentiometric titration"],"techniques_zh":["电位滴定法"],"techniques_cs":["potenciometrickou titrací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zasadowości – kwasowej pojemności neutralizacyjnej (KNK4,5; KNK8,3)\nZakres:\nKNK4,5 (do pH 4,5)\nKNK8,3 (do pH 8,3)\nMetoda miareczkowania potencjometrycznego","reference":"PP-ST-SL-04-02 (ČSN EN ISO 9963-1)","norm_bases":["PP-ST-SL-04-02","ČSN EN ISO 9963-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie zasadowości – kwasowej pojemności neutralizacyjnej (KNK4,5; KNK8,3) Metoda miareczkowania potencjometrycznego KNK4,5 (do pH 4,5)  KNK8,3 (do pH 8,3)  Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení kyselinové neutralizační kapacity (KNK4,5; KNK8,3) potenciometrickou titrací KNK4,5  KNK8,3  PP-ST-SL-04-02 (ČSN EN ISO 9963-1) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie zasadowosci – kwasowej pojemnosci neutralizacyjnej (KNK4,5; KNK8,3) Metoda miareczkowania potencjometrycznego KNK4,5 (do pH 4,5)  KNK8,3 (do pH 8,3)  Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni kyselinove neutralizacni kapacity (KNK4,5; KNK8,3) potenciometrickou titraci KNK4,5  KNK8,3  PP-ST-SL-04-02 (CSN EN ISO 9963-1)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of acid neutralizing capacity (alkalinity) (KNK4.5; KNK8.3) Potentiometric titration KNK4.5 (to pH 4.5)  KNK8.3 (to pH 8.3)  PP-ST-SL-04-02 (ČSN EN ISO 9963-1)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 酸中和能力（碱度）测定（KNK4.5；KNK8.3） 电位滴定法 KNK4.5（至pH 4.5）  KNK8.3（至pH 8.3）  PP-ST-SL-04-02 (ČSN EN ISO 9963-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b155fe333ff473c0dc48de9f","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"4","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie chlorków","methodology_en":"Determination of chlorides","methodology_zh":"氯化物测定","methodology_cs":"Stanovení chloridů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda miareczkowania potencjometrycznego według Mohra","technique_en":"Potentiometric titration according to Mohr","technique_zh":"莫尔电位滴定法","technique_cs":"potenciometrickou titrací podle Mohra","techniques":["Metoda miareczkowania potencjometrycznego według Mohra"],"techniques_en":["Potentiometric titration according to Mohr"],"techniques_zh":["莫尔电位滴定法"],"techniques_cs":["potenciometrickou titrací podle Mohra"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków\nMetoda miareczkowania potencjometrycznego według Mohra","reference":"PP-ST-SL-05-02 (ČSN ISO 9297)","norm_bases":["PP-ST-SL-05-02","ČSN ISO 9297"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie chlorków Metoda miareczkowania potencjometrycznego według Mohra Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení chloridů potenciometrickou titrací podle Mohra PP-ST-SL-05-02 (ČSN ISO 9297) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie chlorkow Metoda miareczkowania potencjometrycznego wedlug Mohra Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni chloridu potenciometrickou titraci podle Mohra PP-ST-SL-05-02 (CSN ISO 9297)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of chlorides Potentiometric titration according to Mohr PP-ST-SL-05-02 (ČSN ISO 9297)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 氯化物测定 莫尔电位滴定法 PP-ST-SL-05-02 (ČSN ISO 9297)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0c94e3fa4c9557c1a8b0f089","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"5","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie zawiesin ogólnych (NL 105)","methodology_en":"Determination of suspended solids (NL 105)","methodology_zh":"悬浮物测定（NL 105）","methodology_cs":"Stanovení nerozpuštěných látek (NL 105)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda wagowa","technique_en":"Gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["Metoda wagowa"],"techniques_en":["Gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesin ogólnych (NL 105)\nMetoda wagowa","reference":"PP-ST-SL-06-02 (ČSN EN 872)","norm_bases":["PP-ST-SL-06-02","ČSN EN 872"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie zawiesin ogólnych (NL 105) Metoda wagowa Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení nerozpuštěných látek (NL 105) gravimetricky PP-ST-SL-06-02 (ČSN EN 872) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie zawiesin ogolnych (NL 105) Metoda wagowa Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni nerozpustenych latek (NL 105) gravimetricky PP-ST-SL-06-02 (CSN EN 872)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of suspended solids (NL 105) Gravimetry PP-ST-SL-06-02 (ČSN EN 872)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 悬浮物测定（NL 105） 重量法 PP-ST-SL-06-02 (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"473a64933d7174693f496061","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"6","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie substancji rozpuszczonych (RL 105, RL 130, RL 550, RAS)","methodology_en":"Determination of dissolved solids (RL 105, RL 130, RL 550, RAS)","methodology_zh":"溶解性固体测定（RL 105、RL 130、RL 550、RAS）","methodology_cs":"Stanovení rozpuštěných látek (RL 105, RL 130, RL 550, RAS)","parameters":[{"name":"RL 105","range":""},{"name":"RL 130","range":""},{"name":"RL 550","range":""},{"name":"RAS","range":""}],"parameters_en":[{"name":"RL 105","range":""},{"name":"RL 130","range":""},{"name":"RL 550","range":""},{"name":"RAS","range":""}],"parameters_zh":[{"name":"RL 105","range":""},{"name":"RL 130","range":""},{"name":"RL 550","range":""},{"name":"RAS","range":""}],"parameters_cs":[{"name":"RL 105","range":""},{"name":"RL 130","range":""},{"name":"RL 550","range":""},{"name":"RAS","range":""}],"technique":"Metoda wagowa","technique_en":"Gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["Metoda wagowa"],"techniques_en":["Gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych (RL 105, RL 130, RL 550, RAS)\nZakres:\nRL 105\nRL 130\nRL 550\nRAS\nMetoda wagowa","reference":"PP-ST-SL-07-02 (ČSN 75 7346; ČSN 75 7347)","norm_bases":["PP-ST-SL-07-02","ČSN 75 7346","ČSN 75 7347"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie substancji rozpuszczonych (RL 105, RL 130, RL 550, RAS) Metoda wagowa RL 105  RL 130  RL 550  RAS  Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení rozpuštěných látek (RL 105, RL 130, RL 550, RAS) gravimetricky RL 105  RL 130  RL 550  RAS  PP-ST-SL-07-02 (ČSN 75 7346; ČSN 75 7347) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie substancji rozpuszczonych (RL 105, RL 130, RL 550, RAS) Metoda wagowa RL 105  RL 130  RL 550  RAS  Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni rozpustenych latek (RL 105, RL 130, RL 550, RAS) gravimetricky RL 105  RL 130  RL 550  RAS  PP-ST-SL-07-02 (CSN 75 7346; CSN 75 7347)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of dissolved solids (RL 105, RL 130, RL 550, RAS) Gravimetry RL 105  RL 130  RL 550  RAS  PP-ST-SL-07-02 (ČSN 75 7346; ČSN 75 7347)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 溶解性固体测定（RL 105、RL 130、RL 550、RAS） 重量法 RL 105  RL 130  RL 550  RAS  PP-ST-SL-07-02 (ČSN 75 7346; ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f8774d399cd7e5d9e1568f1a","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"7","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu metodą dichromianową (ChZT-Cr)","methodology_en":"Determination of chemical oxygen demand by dichromate (COD-Cr)","methodology_zh":"重铬酸盐法化学需氧量测定（COD-Cr）","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem (CHSKCr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna – komercyjny zestaw analityczny HACH","technique_en":"Spectrophotometry – HACH commercial analytical kit","technique_zh":"分光光度法 – HACH商用分析试剂盒","technique_cs":"spektrofotometricky – analytická komerční souprava HACH","techniques":["Metoda spektrofotometryczna – komercyjny zestaw analityczny HACH"],"techniques_en":["Spectrophotometry – HACH commercial analytical kit"],"techniques_zh":["分光光度法 – HACH商用分析试剂盒"],"techniques_cs":["spektrofotometricky – analytická komerční souprava HACH"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu metodą dichromianową (ChZT-Cr)\nMetoda spektrofotometryczna – komercyjny zestaw analityczny HACH","reference":"PP-ST-SL-01-11 (ČSN ISO 15705; návod firmy HACH)","norm_bases":["PP-ST-SL-01-11","ČSN ISO 15705","návod firmy HACH"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie chemicznego zapotrzebowania tlenu metodą dichromianową (ChZT-Cr) Metoda spektrofotometryczna – komercyjny zestaw analityczny HACH Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení chemické spotřeby kyslíku dichromanem (CHSKCr) spektrofotometricky – analytická komerční souprava HACH PP-ST-SL-01-11 (ČSN ISO 15705; návod firmy HACH) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie chemicznego zapotrzebowania tlenu metoda dichromianowa (ChZT-Cr) Metoda spektrofotometryczna – komercyjny zestaw analityczny HACH Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni chemicke spotreby kysliku dichromanem (CHSKCr) spektrofotometricky – analyticka komercni souprava HACH PP-ST-SL-01-11 (CSN ISO 15705; navod firmy HACH)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of chemical oxygen demand by dichromate (COD-Cr) Spectrophotometry – HACH commercial analytical kit PP-ST-SL-01-11 (ČSN ISO 15705; návod firmy HACH)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 重铬酸盐法化学需氧量测定（COD-Cr） 分光光度法 – HACH商用分析试剂盒 PP-ST-SL-01-11 (ČSN ISO 15705; návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d2e0c6d8933166e312e9496a","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"8","test_object":"Ścieki, wody powierzchniowe, wody kopalniane","test_object_en":"Waste waters, surface waters, mine waters","test_object_zh":"废水、地表水、矿井水","test_object_cs":"Odpadní vody, povrchové vody, důlní vody","methodology":"Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5)","methodology_en":"Determination of biochemical oxygen demand (BOD5)","methodology_zh":"五日生化需氧量测定（BOD5）","methodology_cs":"Stanovení biochemické spotřeby kyslíku (BSK5)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda optyczna – pomiar tlenu czujnikiem optycznym","technique_en":"Oxygen measurement with an optical sensor","technique_zh":"光学传感器测氧法","technique_cs":"metodou měření kyslíku optickým senzorem","techniques":["Metoda optyczna – pomiar tlenu czujnikiem optycznym"],"techniques_en":["Oxygen measurement with an optical sensor"],"techniques_zh":["光学传感器测氧法"],"techniques_cs":["metodou měření kyslíku optickým senzorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5)\nMetoda optyczna – pomiar tlenu czujnikiem optycznym","reference":"PP-ST-SL-03-18 (ČSN EN 1899-1:1999; ČSN EN 1899-2; ČSN ISO 17289","norm_bases":["PP-ST-SL-03-18","ČSN EN 1899-1:1999","ČSN EN 1899-2","ČSN ISO 17289"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, wody powierzchniowe, wody kopalniane Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) Metoda optyczna – pomiar tlenu czujnikiem optycznym Odpadní vody, povrchové vody, důlní vody Stanovení biochemické spotřeby kyslíku (BSK5) metodou měření kyslíku optickým senzorem PP-ST-SL-03-18 (ČSN EN 1899-1:1999; ČSN EN 1899-2; ČSN ISO 17289 Scieki, wody powierzchniowe, wody kopalniane Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) Metoda optyczna – pomiar tlenu czujnikiem optycznym Odpadni vody, povrchove vody, dulni vody Stanoveni biochemicke spotreby kysliku (BSK5) metodou mereni kysliku optickym senzorem PP-ST-SL-03-18 (CSN EN 1899-1:1999; CSN EN 1899-2; CSN ISO 17289","search_en":"Waste waters, surface waters, mine waters Determination of biochemical oxygen demand (BOD5) Oxygen measurement with an optical sensor PP-ST-SL-03-18 (ČSN EN 1899-1:1999; ČSN EN 1899-2; ČSN ISO 17289","search_zh":"废水、地表水、矿井水 五日生化需氧量测定（BOD5） 光学传感器测氧法 PP-ST-SL-03-18 (ČSN EN 1899-1:1999; ČSN EN 1899-2; ČSN ISO 17289","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ca78a86e72189ee80b254e30","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"9","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie fluorków, azotanów i siarczanów","methodology_en":"Determination of fluorides, nitrates and sulphates","methodology_zh":"氟化物、硝酸盐和硫酸盐测定","methodology_cs":"Stanovení fluoridů, dusičnanů a síranů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda chromatografii jonowej","technique_en":"Ion chromatography","technique_zh":"离子色谱法","technique_cs":"iontovou chromatografií","techniques":["Metoda chromatografii jonowej"],"techniques_en":["Ion chromatography"],"techniques_zh":["离子色谱法"],"techniques_cs":["iontovou chromatografií"],"computed":["Azot azotanowy (z obliczeń na podstawie zmierzonych wartości)"],"computed_en":["Nitrate nitrogen (calculated from measured values)"],"computed_zh":["硝酸盐氮（根据测量值计算）"],"computed_cs":["výpočet dusičnanového dusíku z naměřených hodnot"],"activity":"Oznaczanie fluorków, azotanów i siarczanów\nMetoda chromatografii jonowej","reference":"PP-ST-SL-02-20 (ČSN EN ISO 10304-1)","norm_bases":["PP-ST-SL-02-20","ČSN EN ISO 10304-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie fluorków, azotanów i siarczanów Metoda chromatografii jonowej Azot azotanowy (z obliczeń na podstawie zmierzonych wartości) Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení fluoridů, dusičnanů a síranů iontovou chromatografií výpočet dusičnanového dusíku z naměřených hodnot PP-ST-SL-02-20 (ČSN EN ISO 10304-1) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie fluorkow, azotanow i siarczanow Metoda chromatografii jonowej Azot azotanowy (z obliczen na podstawie zmierzonych wartosci) Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni fluoridu, dusicnanu a siranu iontovou chromatografii vypocet dusicnanoveho dusiku z namerenych hodnot PP-ST-SL-02-20 (CSN EN ISO 10304-1)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of fluorides, nitrates and sulphates Ion chromatography Nitrate nitrogen (calculated from measured values) PP-ST-SL-02-20 (ČSN EN ISO 10304-1)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 氟化物、硝酸盐和硫酸盐测定 离子色谱法 硝酸盐氮（根据测量值计算） PP-ST-SL-02-20 (ČSN EN ISO 10304-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fc1a417906719ce2f99e65c7","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"10","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie fosforu ogólnego (P og.)","methodology_en":"Determination of total phosphorus (P total)","methodology_zh":"总磷测定（总P）","methodology_cs":"Stanovení celkového fosforu (P celk.)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna – komercyjny zestaw analityczny HACH","technique_en":"Spectrophotometry – HACH commercial analytical kit","technique_zh":"分光光度法 – HACH商用分析试剂盒","technique_cs":"spektrofotometricky – analytická komerční souprava HACH","techniques":["Metoda spektrofotometryczna – komercyjny zestaw analityczny HACH"],"techniques_en":["Spectrophotometry – HACH commercial analytical kit"],"techniques_zh":["分光光度法 – HACH商用分析试剂盒"],"techniques_cs":["spektrofotometricky – analytická komerční souprava HACH"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforu ogólnego (P og.)\nMetoda spektrofotometryczna – komercyjny zestaw analityczny HACH","reference":"PP-ST-SL-02-23 (ČSN EN ISO 6878; návod firmy HACH)","norm_bases":["PP-ST-SL-02-23","ČSN EN ISO 6878","návod firmy HACH"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie fosforu ogólnego (P og.) Metoda spektrofotometryczna – komercyjny zestaw analityczny HACH Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení celkového fosforu (P celk.) spektrofotometricky – analytická komerční souprava HACH PP-ST-SL-02-23 (ČSN EN ISO 6878; návod firmy HACH) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie fosforu ogolnego (P og.) Metoda spektrofotometryczna – komercyjny zestaw analityczny HACH Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni celkoveho fosforu (P celk.) spektrofotometricky – analyticka komercni souprava HACH PP-ST-SL-02-23 (CSN EN ISO 6878; navod firmy HACH)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of total phosphorus (P total) Spectrophotometry – HACH commercial analytical kit PP-ST-SL-02-23 (ČSN EN ISO 6878; návod firmy HACH)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 总磷测定（总P） 分光光度法 – HACH商用分析试剂盒 PP-ST-SL-02-23 (ČSN EN ISO 6878; návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3d5e6f2aab87777647c7190a","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"11","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie ortofosforanów","methodology_en":"Determination of orthophosphates","methodology_zh":"正磷酸盐测定","methodology_cs":"Stanovení ortofosforečnanů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"Spectrophotometry","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["Spectrophotometry"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ortofosforanów\nMetoda spektrofotometryczna","reference":"PP-ST-SL-14-02 (ČSN EN ISO 6878)","norm_bases":["PP-ST-SL-14-02","ČSN EN ISO 6878"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie ortofosforanów Metoda spektrofotometryczna Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení ortofosforečnanů spektrofotometricky PP-ST-SL-14-02 (ČSN EN ISO 6878) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie ortofosforanow Metoda spektrofotometryczna Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni ortofosforecnanu spektrofotometricky PP-ST-SL-14-02 (CSN EN ISO 6878)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of orthophosphates Spectrophotometry PP-ST-SL-14-02 (ČSN EN ISO 6878)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 正磷酸盐测定 分光光度法 PP-ST-SL-14-02 (ČSN EN ISO 6878)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4c38d995ad77b72806ebfa8","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"12","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie azotynów","methodology_en":"Determination of nitrites","methodology_zh":"亚硝酸盐测定","methodology_cs":"Stanovení dusitanů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"Spectrophotometry","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["Spectrophotometry"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":["Azot azotynowy (z obliczeń na podstawie zmierzonych wartości)"],"computed_en":["Nitrite nitrogen (calculated from measured values)"],"computed_zh":["亚硝酸盐氮（根据测量值计算）"],"computed_cs":["výpočet dusitanového dusíku z naměřených hodnot"],"activity":"Oznaczanie azotynów\nMetoda spektrofotometryczna","reference":"PP-ST-SL-15-02 (ČSN EN 26777)","norm_bases":["PP-ST-SL-15-02","ČSN EN 26777"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie azotynów Metoda spektrofotometryczna Azot azotynowy (z obliczeń na podstawie zmierzonych wartości) Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení dusitanů spektrofotometricky výpočet dusitanového dusíku z naměřených hodnot PP-ST-SL-15-02 (ČSN EN 26777) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie azotynow Metoda spektrofotometryczna Azot azotynowy (z obliczen na podstawie zmierzonych wartosci) Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni dusitanu spektrofotometricky vypocet dusitanoveho dusiku z namerenych hodnot PP-ST-SL-15-02 (CSN EN 26777)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of nitrites Spectrophotometry Nitrite nitrogen (calculated from measured values) PP-ST-SL-15-02 (ČSN EN 26777)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 亚硝酸盐测定 分光光度法 亚硝酸盐氮（根据测量值计算） PP-ST-SL-15-02 (ČSN EN 26777)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6626d74a923c32246a313e96","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"13","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie jonów amonowych","methodology_en":"Determination of ammonium ions","methodology_zh":"铵离子测定","methodology_cs":"Stanovení amonných iontů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda potencjometryczna","technique_en":"Potentiometry","technique_zh":"电位法","technique_cs":"potenciometricky","techniques":["Metoda potencjometryczna"],"techniques_en":["Potentiometry"],"techniques_zh":["电位法"],"techniques_cs":["potenciometricky"],"computed":["Azot amonowy (z obliczeń na podstawie zmierzonych wartości)"],"computed_en":["Ammonium nitrogen (calculated from measured values)"],"computed_zh":["氨氮（根据测量值计算）"],"computed_cs":["výpočet amoniakálního dusíku z naměřených hodnot"],"activity":"Oznaczanie jonów amonowych\nMetoda potencjometryczna","reference":"PP-ST-SL-19-02 (ČSN ISO 6778)","norm_bases":["PP-ST-SL-19-02","ČSN ISO 6778"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie jonów amonowych Metoda potencjometryczna Azot amonowy (z obliczeń na podstawie zmierzonych wartości) Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení amonných iontů potenciometricky výpočet amoniakálního dusíku z naměřených hodnot PP-ST-SL-19-02 (ČSN ISO 6778) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie jonow amonowych Metoda potencjometryczna Azot amonowy (z obliczen na podstawie zmierzonych wartosci) Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni amonnych iontu potenciometricky vypocet amoniakalniho dusiku z namerenych hodnot PP-ST-SL-19-02 (CSN ISO 6778)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of ammonium ions Potentiometry Ammonium nitrogen (calculated from measured values) PP-ST-SL-19-02 (ČSN ISO 6778)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 铵离子测定 电位法 氨氮（根据测量值计算） PP-ST-SL-19-02 (ČSN ISO 6778)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c9e337288998b1d5eb93c54f","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"14","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie azotu amonowego","methodology_en":"Determination of ammonium nitrogen","methodology_zh":"氨氮测定","methodology_cs":"Stanovení amoniakálního dusíku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"Spectrophotometry","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["Spectrophotometry"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":["Jony amonowe (z obliczeń na podstawie zmierzonych wartości)"],"computed_en":["Ammonium ions (calculated from measured values)"],"computed_zh":["铵离子（根据测量值计算）"],"computed_cs":["výpočet amonných iontů z naměřených hodnot"],"activity":"Oznaczanie azotu amonowego\nMetoda spektrofotometryczna","reference":"PP-ST-SL-20-02 (ČSN ISO 7150-1)","norm_bases":["PP-ST-SL-20-02","ČSN ISO 7150-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie azotu amonowego Metoda spektrofotometryczna Jony amonowe (z obliczeń na podstawie zmierzonych wartości) Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení amoniakálního dusíku spektrofotometricky výpočet amonných iontů z naměřených hodnot PP-ST-SL-20-02 (ČSN ISO 7150-1) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie azotu amonowego Metoda spektrofotometryczna Jony amonowe (z obliczen na podstawie zmierzonych wartosci) Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni amoniakalniho dusiku spektrofotometricky vypocet amonnych iontu z namerenych hodnot PP-ST-SL-20-02 (CSN ISO 7150-1)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of ammonium nitrogen Spectrophotometry Ammonium ions (calculated from measured values) PP-ST-SL-20-02 (ČSN ISO 7150-1)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 氨氮测定 分光光度法 铵离子（根据测量值计算） PP-ST-SL-20-02 (ČSN ISO 7150-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c2b81bc87ae6d8792ec250f0","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"15","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie azotu ogólnego (N og.)","methodology_en":"Determination of total nitrogen (N total)","methodology_zh":"总氮测定（总N）","methodology_cs":"Stanovení celkového dusíku (N celk.)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna – komercyjny zestaw analityczny HACH","technique_en":"Spectrophotometry – HACH commercial analytical kit","technique_zh":"分光光度法 – HACH商用分析试剂盒","technique_cs":"spektrofotometricky – analytická komerční souprava HACH","techniques":["Metoda spektrofotometryczna – komercyjny zestaw analityczny HACH"],"techniques_en":["Spectrophotometry – HACH commercial analytical kit"],"techniques_zh":["分光光度法 – HACH商用分析试剂盒"],"techniques_cs":["spektrofotometricky – analytická komerční souprava HACH"],"computed":["Azot nieorganiczny (z obliczeń)"],"computed_en":["Inorganic nitrogen (calculated)"],"computed_zh":["无机氮（计算）"],"computed_cs":["dopočet anorganického dusíku"],"activity":"Oznaczanie azotu ogólnego (N og.)\nMetoda spektrofotometryczna – komercyjny zestaw analityczny HACH","reference":"PP-ST-SL-04-08 (návod firmy HACH)","norm_bases":["PP-ST-SL-04-08","návod firmy HACH"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie azotu ogólnego (N og.) Metoda spektrofotometryczna – komercyjny zestaw analityczny HACH Azot nieorganiczny (z obliczeń) Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení celkového dusíku (N celk.) spektrofotometricky – analytická komerční souprava HACH dopočet anorganického dusíku PP-ST-SL-04-08 (návod firmy HACH) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie azotu ogolnego (N og.) Metoda spektrofotometryczna – komercyjny zestaw analityczny HACH Azot nieorganiczny (z obliczen) Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni celkoveho dusiku (N celk.) spektrofotometricky – analyticka komercni souprava HACH dopocet anorganickeho dusiku PP-ST-SL-04-08 (navod firmy HACH)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of total nitrogen (N total) Spectrophotometry – HACH commercial analytical kit Inorganic nitrogen (calculated) PP-ST-SL-04-08 (návod firmy HACH)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 总氮测定（总N） 分光光度法 – HACH商用分析试剂盒 无机氮（计算） PP-ST-SL-04-08 (návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"99e981263e49cb0e35abbbe7","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"16","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie metali","methodology_en":"Determination of metals","methodology_zh":"金属测定","methodology_cs":"Stanovení kovů","parameters":[{"name":"Al (glin)","range":""},{"name":"As (arsen)","range":""},{"name":"Ba (bar)","range":""},{"name":"Be (beryl)","range":""},{"name":"Ca (wapń)","range":""},{"name":"Cd (kadm)","range":""},{"name":"Co (kobalt)","range":""},{"name":"Cr (chrom)","range":""},{"name":"Cu (miedź)","range":""},{"name":"Fe (żelazo)","range":""},{"name":"K (potas)","range":""},{"name":"Mg (magnez)","range":""},{"name":"Mn (mangan)","range":""},{"name":"Na (sód)","range":""},{"name":"Ni (nikiel)","range":""},{"name":"Pb (ołów)","range":""},{"name":"V (wanad)","range":""},{"name":"Zn (cynk)","range":""}],"parameters_en":[{"name":"Al (aluminium)","range":""},{"name":"As (arsenic)","range":""},{"name":"Ba (barium)","range":""},{"name":"Be (beryllium)","range":""},{"name":"Ca (calcium)","range":""},{"name":"Cd (cadmium)","range":""},{"name":"Co (cobalt)","range":""},{"name":"Cr (chromium)","range":""},{"name":"Cu (copper)","range":""},{"name":"Fe (iron)","range":""},{"name":"K (potassium)","range":""},{"name":"Mg (magnesium)","range":""},{"name":"Mn (manganese)","range":""},{"name":"Na (sodium)","range":""},{"name":"Ni (nickel)","range":""},{"name":"Pb (lead)","range":""},{"name":"V (vanadium)","range":""},{"name":"Zn (zinc)","range":""}],"parameters_zh":[{"name":"Al（铝）","range":""},{"name":"As（砷）","range":""},{"name":"Ba（钡）","range":""},{"name":"Be（铍）","range":""},{"name":"Ca（钙）","range":""},{"name":"Cd（镉）","range":""},{"name":"Co（钴）","range":""},{"name":"Cr（铬）","range":""},{"name":"Cu（铜）","range":""},{"name":"Fe（铁）","range":""},{"name":"K（钾）","range":""},{"name":"Mg（镁）","range":""},{"name":"Mn（锰）","range":""},{"name":"Na（钠）","range":""},{"name":"Ni（镍）","range":""},{"name":"Pb（铅）","range":""},{"name":"V（钒）","range":""},{"name":"Zn（锌）","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"As","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）","technique_cs":"metodou ICP-OES","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"techniques_en":["Inductively coupled plasma optical emission spectrometry (ICP-OES)"],"techniques_zh":["电感耦合等离子体发射光谱法（ICP-OES）"],"techniques_cs":["metodou ICP-OES"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali\nZakres:\nAl (glin)\nAs (arsen)\nBa (bar)\nBe (beryl)\nCa (wapń)\nCd (kadm)\nCo (kobalt)\nCr (chrom)\nCu (miedź)\nFe (żelazo)\nK (potas)\nMg (magnez)\nMn (mangan)\nNa (sód)\nNi (nikiel)\nPb (ołów)\nV (wanad)\nZn (cynk)\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PP-ST-SL-01-18 (ČSN EN ISO 11885)","norm_bases":["PP-ST-SL-01-18","ČSN EN ISO 11885"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie metali Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Al (glin)  As (arsen)  Ba (bar)  Be (beryl)  Ca (wapń)  Cd (kadm)  Co (kobalt)  Cr (chrom)  Cu (miedź)  Fe (żelazo)  K (potas)  Mg (magnez)  Mn (mangan)  Na (sód)  Ni (nikiel)  Pb (ołów)  V (wanad)  Zn (cynk)  Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení kovů metodou ICP-OES Al  As  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Na  Ni  Pb  V  Zn  PP-ST-SL-01-18 (ČSN EN ISO 11885) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie metali Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Al (glin)  As (arsen)  Ba (bar)  Be (beryl)  Ca (wapn)  Cd (kadm)  Co (kobalt)  Cr (chrom)  Cu (miedz)  Fe (zelazo)  K (potas)  Mg (magnez)  Mn (mangan)  Na (sod)  Ni (nikiel)  Pb (olow)  V (wanad)  Zn (cynk)  Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni kovu metodou ICP-OES Al  As  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Na  Ni  Pb  V  Zn  PP-ST-SL-01-18 (CSN EN ISO 11885)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of metals Inductively coupled plasma optical emission spectrometry (ICP-OES) Al (aluminium)  As (arsenic)  Ba (barium)  Be (beryllium)  Ca (calcium)  Cd (cadmium)  Co (cobalt)  Cr (chromium)  Cu (copper)  Fe (iron)  K (potassium)  Mg (magnesium)  Mn (manganese)  Na (sodium)  Ni (nickel)  Pb (lead)  V (vanadium)  Zn (zinc)  PP-ST-SL-01-18 (ČSN EN ISO 11885)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 金属测定 电感耦合等离子体发射光谱法（ICP-OES） Al（铝）  As（砷）  Ba（钡）  Be（铍）  Ca（钙）  Cd（镉）  Co（钴）  Cr（铬）  Cu（铜）  Fe（铁）  K（钾）  Mg（镁）  Mn（锰）  Na（钠）  Ni（镍）  Pb（铅）  V（钒）  Zn（锌）  PP-ST-SL-01-18 (ČSN EN ISO 11885)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5623cfd0edbbb126a2c23cb9","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"17","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie uranu","methodology_en":"Determination of uranium","methodology_zh":"铀测定","methodology_cs":"Stanovení uranu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"Spectrophotometry","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["Spectrophotometry"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uranu\nMetoda spektrofotometryczna","reference":"PP-ST-SL-34-02 (ČSN 75 7614)","norm_bases":["PP-ST-SL-34-02","ČSN 75 7614"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie uranu Metoda spektrofotometryczna Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení uranu spektrofotometricky PP-ST-SL-34-02 (ČSN 75 7614) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie uranu Metoda spektrofotometryczna Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni uranu spektrofotometricky PP-ST-SL-34-02 (CSN 75 7614)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of uranium Spectrophotometry PP-ST-SL-34-02 (ČSN 75 7614)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 铀测定 分光光度法 PP-ST-SL-34-02 (ČSN 75 7614)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3265774995fee59a19b9e897","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"18","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie radu (226Ra)","methodology_en":"Determination of radium (226Ra)","methodology_zh":"镭（226Ra）测定","methodology_cs":"Stanovení radia (226Ra)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda scyntylacyjna","technique_en":"Scintillation method","technique_zh":"闪烁法","technique_cs":"scintilačně","techniques":["Metoda scyntylacyjna"],"techniques_en":["Scintillation method"],"techniques_zh":["闪烁法"],"techniques_cs":["scintilačně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie radu (226Ra)\nMetoda scyntylacyjna","reference":"PP-ST-SL-35-02 (PNU 83 0501)","norm_bases":["PP-ST-SL-35-02","PNU 83 0501"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie radu (226Ra) Metoda scyntylacyjna Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení radia (226Ra) scintilačně PP-ST-SL-35-02 (PNU 83 0501) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie radu (226Ra) Metoda scyntylacyjna Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni radia (226Ra) scintilacne PP-ST-SL-35-02 (PNU 83 0501)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of radium (226Ra) Scintillation method PP-ST-SL-35-02 (PNU 83 0501)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 镭（226Ra）测定 闪烁法 PP-ST-SL-35-02 (PNU 83 0501)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b0ecb1a5a280b602ac08add1","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"19","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie radu (226Ra) po zatężeniu","methodology_en":"Determination of radium (226Ra) after preconcentration","methodology_zh":"预浓缩后镭（226Ra）测定","methodology_cs":"Stanovení radia (226Ra) po nakoncentrování","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda scyntylacyjnej emanometrii","technique_en":"Scintillation emanometry","technique_zh":"闪烁射气测量法","technique_cs":"scintilační emanometrií","techniques":["Metoda scyntylacyjnej emanometrii"],"techniques_en":["Scintillation emanometry"],"techniques_zh":["闪烁射气测量法"],"techniques_cs":["scintilační emanometrií"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie radu (226Ra) po zatężeniu\nMetoda scyntylacyjnej emanometrii","reference":"PP-ST-SL-01-13 (ČSN 75 7622)","norm_bases":["PP-ST-SL-01-13","ČSN 75 7622"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie radu (226Ra) po zatężeniu Metoda scyntylacyjnej emanometrii Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení radia (226Ra) po nakoncentrování scintilační emanometrií PP-ST-SL-01-13 (ČSN 75 7622) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie radu (226Ra) po zatezeniu Metoda scyntylacyjnej emanometrii Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni radia (226Ra) po nakoncentrovani scintilacni emanometrii PP-ST-SL-01-13 (CSN 75 7622)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of radium (226Ra) after preconcentration Scintillation emanometry PP-ST-SL-01-13 (ČSN 75 7622)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 预浓缩后镭（226Ra）测定 闪烁射气测量法 PP-ST-SL-01-13 (ČSN 75 7622)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f0f0cc7b9c823714a84a1a20","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"20","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie węglowodorów C10-C40 (indeks oleju mineralnego)","methodology_en":"Determination of hydrocarbons C10-C40 (hydrocarbon oil index)","methodology_zh":"C10-C40烃类测定（矿物油指数）","methodology_cs":"Stanovení uhlovodíků C10-C40","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","technique_en":"Gas chromatography with flame ionisation detection (GC-FID)","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","technique_cs":"metodou GC-FID","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"techniques_en":["Gas chromatography with flame ionisation detection (GC-FID)"],"techniques_zh":["气相色谱-火焰离子化检测法（GC-FID）"],"techniques_cs":["metodou GC-FID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C10-C40 (indeks oleju mineralnego)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PP-ST-SL-01-14 (ČSN N ISO 9377-2)","norm_bases":["PP-ST-SL-01-14","ČSN N ISO 9377-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie węglowodorów C10-C40 (indeks oleju mineralnego) Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení uhlovodíků C10-C40 metodou GC-FID PP-ST-SL-01-14 (ČSN N ISO 9377-2) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie weglowodorow C10-C40 (indeks oleju mineralnego) Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni uhlovodiku C10-C40 metodou GC-FID PP-ST-SL-01-14 (CSN N ISO 9377-2)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of hydrocarbons C10-C40 (hydrocarbon oil index) Gas chromatography with flame ionisation detection (GC-FID) PP-ST-SL-01-14 (ČSN N ISO 9377-2)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 C10-C40烃类测定（矿物油指数） 气相色谱-火焰离子化检测法（GC-FID） PP-ST-SL-01-14 (ČSN N ISO 9377-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cf8bf2d4b33d8c0dd401e12a","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"21","test_object":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne","test_object_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions","test_object_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液","test_object_cs":"Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky","methodology":"Oznaczanie temperatury","methodology_en":"Determination of temperature","methodology_zh":"温度测定","methodology_cs":"Stanovení teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury","reference":"PP-ST-SL-01-19 (ČSN 75 7342)","norm_bases":["PP-ST-SL-01-19","ČSN 75 7342"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, z osadników, kopalniane, opadowe, ścieki i resztkowe roztwory technologiczne Oznaczanie temperatury Vody povrchové, odkalištní, důlní, srážkové, odpadní a zbytkové technologické roztoky Stanovení teploty PP-ST-SL-01-19 (ČSN 75 7342) Wody powierzchniowe, z osadnikow, kopalniane, opadowe, scieki i resztkowe roztwory technologiczne Oznaczanie temperatury Vody povrchove, odkalistni, dulni, srazkove, odpadni a zbytkove technologicke roztoky Stanoveni teploty PP-ST-SL-01-19 (CSN 75 7342)","search_en":"Surface, tailings pond, mine, precipitation and waste waters and residual technological solutions Determination of temperature PP-ST-SL-01-19 (ČSN 75 7342)","search_zh":"地表水、尾矿库水、矿井水、降水、废水及残余工艺溶液 温度测定 PP-ST-SL-01-19 (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2ac8871a2764f12e41996c5e","lab_id":"69ad52a4de79e566650fd35e","country":"CZ","accr_number":"1306","accr_body":"ČIA","row_label":"1","test_object":"Ścieki","test_object_en":"Waste waters","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Pobieranie próbek ścieków (pobieranie ręczne i automatycznym próbnikiem)","methodology_en":"Sampling of waste waters (manual sampling and sampling with an automatic sampler)","methodology_zh":"废水采样（手工采样及自动采样器采样）","methodology_cs":"Odběr vzorků odpadních vod (manuální odběr a odběr automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków (pobieranie ręczne i automatycznym próbnikiem)","reference":"PP-ST-SL-21-03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","norm_bases":["PP-ST-SL-21-03","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków (pobieranie ręczne i automatycznym próbnikiem) Odpadní vody Odběr vzorků odpadních vod (manuální odběr a odběr automatickým vzorkovačem PP-ST-SL-21-03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14) Scieki Pobieranie probek sciekow (pobieranie reczne i automatycznym probnikiem) Odpadni vody Odber vzorku odpadnich vod (manualni odber a odber automatickym vzorkovacem PP-ST-SL-21-03 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14)","search_en":"Waste waters Sampling of waste waters (manual sampling and sampling with an automatic sampler) PP-ST-SL-21-03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","search_zh":"废水 废水采样（手工采样及自动采样器采样） PP-ST-SL-21-03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}