{"lab":{"_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","address":"Bělotínská 288, Hranice I - Město, 753 01 Hranice","categories":["construction"],"city":"Hranice","imported_at":"2026-03-08T10:42:44.590Z","methods_count":17,"name":"Cement Hranice, akciová společnost","parse_status":"parsed","parse_version":5,"pdf_files":["1284_454_2023_CS.pdf","1284_454_2023_EN.pdf"],"scope_summary":"Badania mieszanki betonowej, betonu stwardniałego, kruszywa i cementu.","search_text":"cement hranice, akciová společnost bělotínská 288, hranice i - město, 753 01 hranice 1284","status":"active","updated_at":"2026-03-08T14:52:09.961Z","valid_from":"","valid_until":"25-08-2028","website":"www.cement.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.cement.cz","map_coord":[49.569334,17.718217],"map_geo":"nominatim-city","certificate_date":"25.08.2023","certificate_no":"454/2023","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania mieszanki betonowej, betonu stwardniałego, kruszywa i cementu.","en":"Testing of fresh concrete, hardened concrete, aggregate and cement.","zh":"新拌混凝土、硬化混凝土、集料和水泥的检测。","cs":"Zkoušky čerstvého betonu, ztvrdlého betonu, kameniva a cementu."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Betonu","lab_division_cs":"Betonářská laboratoř","lab_division_en":"Concrete Laboratory","lab_division_zh":"混凝土实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"b0c2ce97bef9581197f95991a546d96a1dd2549804785bceb65f4580c35a8a70","source_pdf_url":"https://www.cai.cz/OA/pdf/P454_2023_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"02121f8d27adb562573d3bd6","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"1","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji","methodology_en":"Determination of consistency","methodology_zh":"稠度测定","methodology_cs":"Stanovení konzistence","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda opadu stożka","technique_en":"Slump test","technique_zh":"坍落度法","technique_cs":"sednutím kužele","techniques":["Metoda opadu stożka"],"techniques_en":["Slump test"],"techniques_zh":["坍落度法"],"techniques_cs":["sednutím kužele"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji\nMetoda opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Oznaczanie konsystencji Metoda opadu stożka Čerstvý beton Stanovení konzistence sednutím kužele ČSN EN 12350-2 Mieszanka betonowa (beton swiezy) Oznaczanie konsystencji Metoda opadu stozka Cerstvy beton Stanoveni konzistence sednutim kuzele CSN EN 12350-2","search_en":"Fresh concrete Determination of consistency Slump test ČSN EN 12350-2","search_zh":"新拌混凝土 稠度测定 坍落度法 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"56d6e576dfb6a57ecabc6718","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"2","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza","methodology_en":"Determination of air content","methodology_zh":"含气量测定","methodology_cs":"Stanovení obsahu vzduchu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza","reference":"ČSN EN 12350-7, mimo čl. 5","norm_bases":["ČSN EN 12350-7, mimo čl. 5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Oznaczanie zawartości powietrza Čerstvý beton Stanovení obsahu vzduchu ČSN EN 12350-7, mimo čl. 5 Mieszanka betonowa (beton swiezy) Oznaczanie zawartosci powietrza Cerstvy beton Stanoveni obsahu vzduchu CSN EN 12350-7, mimo cl. 5","search_en":"Fresh concrete Determination of air content ČSN EN 12350-7, mimo čl. 5","search_zh":"新拌混凝土 含气量测定 ČSN EN 12350-7, mimo čl. 5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4932f5d75ddba7865954ab96","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"3","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Oznaczanie gęstości Čerstvý beton Stanovení objemové hmotnosti ČSN EN 12350-6 Mieszanka betonowa (beton swiezy) Oznaczanie gestosci Cerstvy beton Stanoveni objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Determination of density ČSN EN 12350-6","search_zh":"新拌混凝土 密度测定 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"38f99f9f074e68bdf366472a","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"4","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na rozciąganie przy zginaniu próbek do badań","methodology_en":"Determination of flexural strength of test specimens","methodology_zh":"试件抗折强度测定","methodology_cs":"Stanovení pevnosti v tahu ohybem zkušebních těles","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na rozciąganie przy zginaniu próbek do badań","reference":"ČSN EN 12390-5","norm_bases":["ČSN EN 12390-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na rozciąganie przy zginaniu próbek do badań Ztvrdlý beton Stanovení pevnosti v tahu ohybem zkušebních těles ČSN EN 12390-5 Beton stwardnialy Oznaczanie wytrzymalosci na rozciaganie przy zginaniu probek do badan Ztvrdly beton Stanoveni pevnosti v tahu ohybem zkusebnich teles CSN EN 12390-5","search_en":"Hardened concrete Determination of flexural strength of test specimens ČSN EN 12390-5","search_zh":"硬化混凝土 试件抗折强度测定 ČSN EN 12390-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"97e31796df4e2e9e11ac4946","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"5","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie próbek do badań","methodology_en":"Determination of compressive strength of test specimens","methodology_zh":"试件抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku zkušebních těles","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie próbek do badań","reference":"ČSN EN 12390-3","norm_bases":["ČSN EN 12390-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie próbek do badań Ztvrdlý beton Stanovení pevnosti v tlaku zkušebních těles ČSN EN 12390-3 Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie probek do badan Ztvrdly beton Stanoveni pevnosti v tlaku zkusebnich teles CSN EN 12390-3","search_en":"Hardened concrete Determination of compressive strength of test specimens ČSN EN 12390-3","search_zh":"硬化混凝土 试件抗压强度测定 ČSN EN 12390-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"632438eabdadb1056eb8933d","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"6","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na rozciąganie przy rozłupywaniu próbek do badań","methodology_en":"Determination of tensile splitting strength of test specimens","methodology_zh":"试件劈裂抗拉强度测定","methodology_cs":"Stanovení pevnosti v příčném tahu zkušebních těles","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na rozciąganie przy rozłupywaniu próbek do badań","reference":"ČSN EN 12390-6","norm_bases":["ČSN EN 12390-6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na rozciąganie przy rozłupywaniu próbek do badań Ztvrdlý beton Stanovení pevnosti v příčném tahu zkušebních těles ČSN EN 12390-6 Beton stwardnialy Oznaczanie wytrzymalosci na rozciaganie przy rozlupywaniu probek do badan Ztvrdly beton Stanoveni pevnosti v pricnem tahu zkusebnich teles CSN EN 12390-6","search_en":"Hardened concrete Determination of tensile splitting strength of test specimens ČSN EN 12390-6","search_zh":"硬化混凝土 试件劈裂抗拉强度测定 ČSN EN 12390-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d4f464965b7adf5e7ece60c5","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"7","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12390-7, mimo čl. 6.1.2 a)","norm_bases":["ČSN EN 12390-7, mimo čl. 6.1.2 a)"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7, mimo čl. 6.1.2 a) Beton stwardnialy Oznaczanie gestosci Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7, mimo cl. 6.1.2 a)","search_en":"Hardened concrete Determination of density ČSN EN 12390-7, mimo čl. 6.1.2 a)","search_zh":"硬化混凝土 密度测定 ČSN EN 12390-7, mimo čl. 6.1.2 a)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e3996c641275fff36fe09e1e","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"8","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie odporności powierzchni betonu cementowego na działanie wody i chemicznych środków odladzających","methodology_en":"Determination of resistance of cement concrete surface to water and chemical de-icing agents","methodology_zh":"水泥混凝土表面抗水及化学除冰剂性能测定","methodology_cs":"Stanovení odolnosti povrchu cementového betonu proti působení vody a chemických rozmrazovacích látek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności powierzchni betonu cementowego na działanie wody i chemicznych środków odladzających","reference":"ČSN 73 1326, metoda A, čl. 13-23","norm_bases":["ČSN 73 1326, metoda A, čl. 13-23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie odporności powierzchni betonu cementowego na działanie wody i chemicznych środków odladzających Ztvrdlý beton Stanovení odolnosti povrchu cementového betonu proti působení vody a chemických rozmrazovacích látek ČSN 73 1326, metoda A, čl. 13-23 Beton stwardnialy Oznaczanie odpornosci powierzchni betonu cementowego na dzialanie wody i chemicznych srodkow odladzajacych Ztvrdly beton Stanoveni odolnosti povrchu cementoveho betonu proti pusobeni vody a chemickych rozmrazovacich latek CSN 73 1326, metoda A, cl. 13-23","search_en":"Hardened concrete Determination of resistance of cement concrete surface to water and chemical de-icing agents ČSN 73 1326, metoda A, čl. 13-23","search_zh":"硬化混凝土 水泥混凝土表面抗水及化学除冰剂性能测定 ČSN 73 1326, metoda A, čl. 13-23","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8ec9aa9b76722e783c331de2","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"9","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie głębokości penetracji wody pod ciśnieniem","methodology_en":"Determination of depth of penetration of water under pressure","methodology_zh":"压力水渗透深度测定","methodology_cs":"Stanovení hloubky průsaku tlakovou vodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości penetracji wody pod ciśnieniem","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie głębokości penetracji wody pod ciśnieniem Ztvrdlý beton Stanovení hloubky průsaku tlakovou vodou ČSN EN 12390-8 Beton stwardnialy Oznaczanie glebokosci penetracji wody pod cisnieniem Ztvrdly beton Stanoveni hloubky prusaku tlakovou vodou CSN EN 12390-8","search_en":"Hardened concrete Determination of depth of penetration of water under pressure ČSN EN 12390-8","search_zh":"硬化混凝土 压力水渗透深度测定 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"61636a95859337e3aef43dc7","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"10","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie mrozoodporności","methodology_en":"Determination of frost resistance","methodology_zh":"抗冻性测定","methodology_cs":"Stanovení mrazuvzdornosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mrozoodporności","reference":"ČSN 73 1322","norm_bases":["ČSN 73 1322"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie mrozoodporności Ztvrdlý beton Stanovení mrazuvzdornosti ČSN 73 1322 Beton stwardnialy Oznaczanie mrozoodpornosci Ztvrdly beton Stanoveni mrazuvzdornosti CSN 73 1322","search_en":"Hardened concrete Determination of frost resistance ČSN 73 1322","search_zh":"硬化混凝土 抗冻性测定 ČSN 73 1322","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f3e64ae435743f0011bbed6f","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"11","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie gęstości nasypowej i jamistości","methodology_en":"Determination of loose bulk density and voids","methodology_zh":"松散堆积密度和空隙率测定","methodology_cs":"Stanovení sypné hmotnosti a mezerovitosti","parameters":[{"name":"Gęstość nasypowa","range":""},{"name":"Jamistość","range":""}],"parameters_en":[{"name":"Loose bulk density","range":""},{"name":"Voids","range":""}],"parameters_zh":[{"name":"松散堆积密度","range":""},{"name":"空隙率","range":""}],"parameters_cs":[{"name":"sypné hmotnosti","range":""},{"name":"mezerovitosti","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości nasypowej i jamistości\nZakres:\nGęstość nasypowa\nJamistość","reference":"ČSN EN 1097-3, mimo přílohu A, C2","norm_bases":["ČSN EN 1097-3, mimo přílohu A, C2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie gęstości nasypowej i jamistości Gęstość nasypowa  Jamistość  Kamenivo Stanovení sypné hmotnosti a mezerovitosti sypné hmotnosti  mezerovitosti  ČSN EN 1097-3, mimo přílohu A, C2 Kruszywo Oznaczanie gestosci nasypowej i jamistosci Gestosc nasypowa  Jamistosc  Kamenivo Stanoveni sypne hmotnosti a mezerovitosti sypne hmotnosti  mezerovitosti  CSN EN 1097-3, mimo prilohu A, C2","search_en":"Aggregate Determination of loose bulk density and voids Loose bulk density  Voids  ČSN EN 1097-3, mimo přílohu A, C2","search_zh":"集料 松散堆积密度和空隙率测定 松散堆积密度  空隙率  ČSN EN 1097-3, mimo přílohu A, C2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"14851d05dfc8105b18dd5efb","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"12","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie gęstości ziaren i nasiąkliwości","methodology_en":"Determination of particle density and water absorption","methodology_zh":"颗粒密度和吸水率测定","methodology_cs":"Stanovení objemové hmotnosti a nasákavosti","parameters":[{"name":"Gęstość ziaren","range":""},{"name":"Nasiąkliwość","range":""}],"parameters_en":[{"name":"Particle density","range":""},{"name":"Water absorption","range":""}],"parameters_zh":[{"name":"颗粒密度","range":""},{"name":"吸水率","range":""}],"parameters_cs":[{"name":"objemové hmotnosti","range":""},{"name":"nasákavosti","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości ziaren i nasiąkliwości\nZakres:\nGęstość ziaren\nNasiąkliwość","reference":"ČSN EN 1097-6, čl. 1-6, 8-10","norm_bases":["ČSN EN 1097-6, čl. 1-6, 8-10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie gęstości ziaren i nasiąkliwości Gęstość ziaren  Nasiąkliwość  Kamenivo Stanovení objemové hmotnosti a nasákavosti objemové hmotnosti  nasákavosti  ČSN EN 1097-6, čl. 1-6, 8-10 Kruszywo Oznaczanie gestosci ziaren i nasiakliwosci Gestosc ziaren  Nasiakliwosc  Kamenivo Stanoveni objemove hmotnosti a nasakavosti objemove hmotnosti  nasakavosti  CSN EN 1097-6, cl. 1-6, 8-10","search_en":"Aggregate Determination of particle density and water absorption Particle density  Water absorption  ČSN EN 1097-6, čl. 1-6, 8-10","search_zh":"集料 颗粒密度和吸水率测定 颗粒密度  吸水率  ČSN EN 1097-6, čl. 1-6, 8-10","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c373eacbb66e9e7041b9efd6","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"13","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"颗粒级配测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie uziarnienia Kamenivo Stanovení zrnitosti ČSN EN 933-1 Kruszywo Oznaczanie uziarnienia Kamenivo Stanoveni zrnitosti CSN EN 933-1","search_en":"Aggregate Determination of particle size distribution ČSN EN 933-1","search_zh":"集料 颗粒级配测定 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7e5689e852e08acf03af7604","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"14","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie wilgotności","methodology_en":"Determination of water content","methodology_zh":"含水率测定","methodology_cs":"Stanovení vlhkosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności","reference":"ČSN EN 1097-5","norm_bases":["ČSN EN 1097-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie wilgotności Kamenivo Stanovení vlhkosti ČSN EN 1097-5 Kruszywo Oznaczanie wilgotnosci Kamenivo Stanoveni vlhkosti CSN EN 1097-5","search_en":"Aggregate Determination of water content ČSN EN 1097-5","search_zh":"集料 含水率测定 ČSN EN 1097-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ea24eee2b7672e763a945edd","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"15","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie udziału ziaren o wskaźniku kształtu 3 i większym","methodology_en":"Determination of the proportion of particles with shape index 3 and greater","methodology_zh":"形状指数3及以上颗粒含量测定","methodology_cs":"Stanovení podílu zrn o tvarovém indexu 3 a větším","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie udziału ziaren o wskaźniku kształtu 3 i większym","reference":"ČSN EN 933-4","norm_bases":["ČSN EN 933-4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie udziału ziaren o wskaźniku kształtu 3 i większym Kamenivo Stanovení podílu zrn o tvarovém indexu 3 a větším ČSN EN 933-4 Kruszywo Oznaczanie udzialu ziaren o wskazniku ksztaltu 3 i wiekszym Kamenivo Stanoveni podilu zrn o tvarovem indexu 3 a vetsim CSN EN 933-4","search_en":"Aggregate Determination of the proportion of particles with shape index 3 and greater ČSN EN 933-4","search_zh":"集料 形状指数3及以上颗粒含量测定 ČSN EN 933-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f273fd502525b75f713aac60","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"16","test_object":"Cement","test_object_en":"Cement","test_object_zh":"水泥","test_object_cs":"Cement","methodology":"Oznaczanie wytrzymałości na zginanie i ściskanie","methodology_en":"Determination of flexural and compressive strength","methodology_zh":"抗折和抗压强度测定","methodology_cs":"Stanovení pevnosti v tahu za ohybu a v tlaku","parameters":[{"name":"Wytrzymałość na zginanie","range":""},{"name":"Wytrzymałość na ściskanie","range":""}],"parameters_en":[{"name":"Flexural strength","range":""},{"name":"Compressive strength","range":""}],"parameters_zh":[{"name":"抗折强度","range":""},{"name":"抗压强度","range":""}],"parameters_cs":[{"name":"pevnosti v tahu za ohybu","range":""},{"name":"pevnosti v tlaku","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na zginanie i ściskanie\nZakres:\nWytrzymałość na zginanie\nWytrzymałość na ściskanie","reference":"ČSN EN 196-1, čl. 9","norm_bases":["ČSN EN 196-1, čl. 9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Cement Oznaczanie wytrzymałości na zginanie i ściskanie Wytrzymałość na zginanie  Wytrzymałość na ściskanie  Cement Stanovení pevnosti v tahu za ohybu a v tlaku pevnosti v tahu za ohybu  pevnosti v tlaku  ČSN EN 196-1, čl. 9 Cement Oznaczanie wytrzymalosci na zginanie i sciskanie Wytrzymalosc na zginanie  Wytrzymalosc na sciskanie  Cement Stanoveni pevnosti v tahu za ohybu a v tlaku pevnosti v tahu za ohybu  pevnosti v tlaku  CSN EN 196-1, cl. 9","search_en":"Cement Determination of flexural and compressive strength Flexural strength  Compressive strength  ČSN EN 196-1, čl. 9","search_zh":"水泥 抗折和抗压强度测定 抗折强度  抗压强度  ČSN EN 196-1, čl. 9","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ebd224c8717e568277bbcedc","lab_id":"69ad52a4de79e566650fd342","country":"CZ","accr_number":"1284","accr_body":"ČIA","row_label":"17","test_object":"Jastrych","test_object_en":"Screed","test_object_zh":"找平层","test_object_cs":"Potěr","methodology":"Oznaczanie wytrzymałości na zginanie i ściskanie","methodology_en":"Determination of flexural and compressive strength","methodology_zh":"抗折和抗压强度测定","methodology_cs":"Stanovení pevnosti v tahu za ohybu a v tlaku","parameters":[{"name":"Wytrzymałość na zginanie","range":""},{"name":"Wytrzymałość na ściskanie","range":""}],"parameters_en":[{"name":"Flexural strength","range":""},{"name":"Compressive strength","range":""}],"parameters_zh":[{"name":"抗折强度","range":""},{"name":"抗压强度","range":""}],"parameters_cs":[{"name":"pevnosti v tahu za ohybu","range":""},{"name":"pevnosti v tlaku","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na zginanie i ściskanie\nZakres:\nWytrzymałość na zginanie\nWytrzymałość na ściskanie","reference":"ČSN EN 13892-2","norm_bases":["ČSN EN 13892-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Jastrych Oznaczanie wytrzymałości na zginanie i ściskanie Wytrzymałość na zginanie  Wytrzymałość na ściskanie  Potěr Stanovení pevnosti v tahu za ohybu a v tlaku pevnosti v tahu za ohybu  pevnosti v tlaku  ČSN EN 13892-2 Jastrych Oznaczanie wytrzymalosci na zginanie i sciskanie Wytrzymalosc na zginanie  Wytrzymalosc na sciskanie  Poter Stanoveni pevnosti v tahu za ohybu a v tlaku pevnosti v tahu za ohybu  pevnosti v tlaku  CSN EN 13892-2","search_en":"Screed Determination of flexural and compressive strength Flexural strength  Compressive strength  ČSN EN 13892-2","search_zh":"找平层 抗折和抗压强度测定 抗折强度  抗压强度  ČSN EN 13892-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}