{"lab":{"_id":"69ad52a4de79e566650fd340","country":"CZ","accr_number":"1281","accr_body":"ČIA","address":"Naskové 1100/3, Košíře, 150 00 Praha 5","categories":["construction","environment"],"city":"Praha 5","imported_at":"2026-03-08T10:42:44.590Z","methods_count":5,"name":"ZKV s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1281_49_2024_CS.pdf","1281_49_2024_EN.pdf"],"scope_summary":"Pomiary hałasu w środowisku poza miejscem pracy i w środowisku pracy oraz pomiary właściwości akustycznych pomieszczeń i budynków, w zakresie określonym w załączniku do świadectwa.","search_text":"zkv s.r.o. naskové 1100/3, košíře, 150 00 praha 5 1281","status":"active","updated_at":"2026-03-08T14:52:09.959Z","valid_from":"","valid_until":"05-02-2029","website":"www.zkv.cz","location":{"type":"Point","coordinates":[14.4378,50.0755]},"map_coord":[50.062925,14.360689],"map_geo":"nominatim-street","certificate_date":"20.07.2026","certificate_no":"352/2026","certificate_replaces":"49/2024 z 05.02.2024","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pomiary hałasu w środowisku poza miejscem pracy i w środowisku pracy oraz pomiary właściwości akustycznych pomieszczeń i budynków, w zakresie określonym w załączniku do świadectwa.","en":"Measurement of noise in the non-working and working environment and measurement of acoustic properties of rooms and buildings, to the extent specified in the appendix to this Certificate.","zh":"非工作环境和工作环境噪声测量以及房间和建筑物声学性能测量，范围见本证书附件。","cs":"Měření hluku v mimopracovním a pracovním prostředí a měření akustických vlastností prostorů a staveb, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze ZKV","lab_division_cs":"Zkušební laboratoř ZKV","lab_division_en":"ZKV Testing Laboratory","lab_division_zh":"ZKV检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników badań.","en":"The laboratory provides opinions and interpretations of the test results.","zh":"实验室提供检测结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků zkoušek."}],"source_lang":"cs","source_pdf_sha256":"9030dd18bd93ab1844981485fc3e3ed717bc715bf6a7aea8e5c21c7a18ccfa59","source_pdf_url":"https://www.cai.cz/OA/pdf/352_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"91f0a225085e494e1d9ffab1","lab_id":"69ad52a4de79e566650fd340","country":"CZ","accr_number":"1281","accr_body":"ČIA","row_label":"1","test_object":"Środowisko poza miejscem pracy (środowisko, przestrzenie zewnętrzne i wewnętrzne, otoczenie transportu lotniczego)","test_object_en":"Non-working environment (living environment, outdoor and indoor spaces, external environment of air transport)","test_object_zh":"非工作环境（生活环境、室外和室内空间、航空运输外部环境）","test_object_cs":"Mimopracovní prostředí (životní prostředí, venkovní a vnitřní prostory, vnější prostředí letecké dopravy)","methodology":"Pomiar hałasu","methodology_en":"Noise measurement","methodology_zh":"噪声测量","methodology_cs":"Měření hluku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar hałasu","reference":"ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR č. 14/2023, část 3; Metodický návod MZ ČR č. OVZ-32.0-19.02.2007/6306","norm_bases":["ČSN ISO 1996-1","ČSN ISO 1996-2","Věstník MZ ČR č. 14/2023, část 3","Metodický návod MZ ČR č. OVZ-32.0-19.02.2007/6306"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko poza miejscem pracy (środowisko, przestrzenie zewnętrzne i wewnętrzne, otoczenie transportu lotniczego) Pomiar hałasu Mimopracovní prostředí (životní prostředí, venkovní a vnitřní prostory, vnější prostředí letecké dopravy) Měření hluku ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR č. 14/2023, část 3; Metodický návod MZ ČR č. OVZ-32.0-19.02.2007/6306 Srodowisko poza miejscem pracy (srodowisko, przestrzenie zewnetrzne i wewnetrzne, otoczenie transportu lotniczego) Pomiar halasu Mimopracovni prostredi (zivotni prostredi, venkovni a vnitrni prostory, vnejsi prostredi letecke dopravy) Mereni hluku CSN ISO 1996-1; CSN ISO 1996-2; Vestnik MZ CR c. 14/2023, cast 3; Metodicky navod MZ CR c. OVZ-32.0-19.02.2007/6306","search_en":"Non-working environment (living environment, outdoor and indoor spaces, external environment of air transport) Noise measurement ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR č. 14/2023, část 3; Metodický návod MZ ČR č. OVZ-32.0-19.02.2007/6306","search_zh":"非工作环境（生活环境、室外和室内空间、航空运输外部环境） 噪声测量 ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR č. 14/2023, část 3; Metodický návod MZ ČR č. OVZ-32.0-19.02.2007/6306","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75fae8ad8142572ea8249fa9","lab_id":"69ad52a4de79e566650fd340","country":"CZ","accr_number":"1281","accr_body":"ČIA","row_label":"2","test_object":"Środowisko pracy (stanowiska pracy, stanowiska obsługi i inne wyznaczone miejsca)","test_object_en":"Working environment (workplaces, operator positions and other specified locations)","test_object_zh":"工作环境（工作场所、操作位置及其他指定位置）","test_object_cs":"Pracovní prostředí (pracoviště, stanoviště obsluhy a další stanovená místa)","methodology":"Pomiar hałasu","methodology_en":"Noise measurement","methodology_zh":"噪声测量","methodology_cs":"Měření hluku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar hałasu","reference":"ČSN EN ISO 9612; ČSN EN ISO 11201; ČSN EN ISO 11202; ČSN EN ISO 11203; ČSN EN ISO 11204; Věstník MZ ČR č. 4/2013, část 4","norm_bases":["ČSN EN ISO 9612","ČSN EN ISO 11201","ČSN EN ISO 11202","ČSN EN ISO 11203","ČSN EN ISO 11204","Věstník MZ ČR č. 4/2013, část 4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko pracy (stanowiska pracy, stanowiska obsługi i inne wyznaczone miejsca) Pomiar hałasu Pracovní prostředí (pracoviště, stanoviště obsluhy a další stanovená místa) Měření hluku ČSN EN ISO 9612; ČSN EN ISO 11201; ČSN EN ISO 11202; ČSN EN ISO 11203; ČSN EN ISO 11204; Věstník MZ ČR č. 4/2013, část 4 Srodowisko pracy (stanowiska pracy, stanowiska obslugi i inne wyznaczone miejsca) Pomiar halasu Pracovni prostredi (pracoviste, stanoviste obsluhy a dalsi stanovena mista) Mereni hluku CSN EN ISO 9612; CSN EN ISO 11201; CSN EN ISO 11202; CSN EN ISO 11203; CSN EN ISO 11204; Vestnik MZ CR c. 4/2013, cast 4","search_en":"Working environment (workplaces, operator positions and other specified locations) Noise measurement ČSN EN ISO 9612; ČSN EN ISO 11201; ČSN EN ISO 11202; ČSN EN ISO 11203; ČSN EN ISO 11204; Věstník MZ ČR č. 4/2013, část 4","search_zh":"工作环境（工作场所、操作位置及其他指定位置） 噪声测量 ČSN EN ISO 9612; ČSN EN ISO 11201; ČSN EN ISO 11202; ČSN EN ISO 11203; ČSN EN ISO 11204; Věstník MZ ČR č. 4/2013, část 4","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e067cb4485d44fa1d7fae444","lab_id":"69ad52a4de79e566650fd340","country":"CZ","accr_number":"1281","accr_body":"ČIA","row_label":"3","test_object":"Pomieszczenia zamknięte w budynkach (pomieszczenia do wykonywania muzyki i mowy, pomieszczenia zwykłe, biura otwarte)","test_object_en":"Enclosed spaces of buildings (performance spaces for music and speech, ordinary rooms, open-plan offices)","test_object_zh":"建筑物封闭空间（音乐和演讲表演空间、普通房间、开放式办公室）","test_object_cs":"Uzavřené prostory staveb (prostory pro přednes hudby a řeči, běžné prostory, otevřené kanceláře)","methodology":"Pomiar czasu pogłosu","methodology_en":"Measurement of reverberation time","methodology_zh":"混响时间测量","methodology_cs":"Měření doby dozvuku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar czasu pogłosu","reference":"ČSN EN ISO 3382-1; ČSN EN ISO 3382-2; ČSN EN ISO 3382-3","norm_bases":["ČSN EN ISO 3382-1","ČSN EN ISO 3382-2","ČSN EN ISO 3382-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomieszczenia zamknięte w budynkach (pomieszczenia do wykonywania muzyki i mowy, pomieszczenia zwykłe, biura otwarte) Pomiar czasu pogłosu Uzavřené prostory staveb (prostory pro přednes hudby a řeči, běžné prostory, otevřené kanceláře) Měření doby dozvuku ČSN EN ISO 3382-1; ČSN EN ISO 3382-2; ČSN EN ISO 3382-3 Pomieszczenia zamkniete w budynkach (pomieszczenia do wykonywania muzyki i mowy, pomieszczenia zwykle, biura otwarte) Pomiar czasu poglosu Uzavrene prostory staveb (prostory pro prednes hudby a reci, bezne prostory, otevrene kancelare) Mereni doby dozvuku CSN EN ISO 3382-1; CSN EN ISO 3382-2; CSN EN ISO 3382-3","search_en":"Enclosed spaces of buildings (performance spaces for music and speech, ordinary rooms, open-plan offices) Measurement of reverberation time ČSN EN ISO 3382-1; ČSN EN ISO 3382-2; ČSN EN ISO 3382-3","search_zh":"建筑物封闭空间（音乐和演讲表演空间、普通房间、开放式办公室） 混响时间测量 ČSN EN ISO 3382-1; ČSN EN ISO 3382-2; ČSN EN ISO 3382-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0a4347a12bf0e51d13e2b66e","lab_id":"69ad52a4de79e566650fd340","country":"CZ","accr_number":"1281","accr_body":"ČIA","row_label":"4","test_object":"Przegrody (stropy, ściany, ściany zewnętrzne, wypełnienia otworów)","test_object_en":"Separating elements (ceilings, walls, façades, openings infill)","test_object_zh":"分隔构件（楼板、墙体、外围护结构、门窗洞口填充）","test_object_cs":"Dělicí konstrukce (stropy, stěny, obvodové pláště, výplně otvorů)","methodology":"Pomiar izolacyjności akustycznej – izolacyjność od dźwięków powietrznych","methodology_en":"Measurement of sound insulation – airborne sound insulation","methodology_zh":"隔声测量–空气声隔声","methodology_cs":"Měření zvukové izolace – vzduchová neprůzvučnost","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności akustycznej – izolacyjność od dźwięków powietrznych","reference":"ČSN EN ISO 717-1; ČSN EN ISO 16283-1; ČSN EN ISO 16283-3","norm_bases":["ČSN EN ISO 717-1","ČSN EN ISO 16283-1","ČSN EN ISO 16283-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody (stropy, ściany, ściany zewnętrzne, wypełnienia otworów) Pomiar izolacyjności akustycznej – izolacyjność od dźwięków powietrznych Dělicí konstrukce (stropy, stěny, obvodové pláště, výplně otvorů) Měření zvukové izolace – vzduchová neprůzvučnost ČSN EN ISO 717-1; ČSN EN ISO 16283-1; ČSN EN ISO 16283-3 Przegrody (stropy, sciany, sciany zewnetrzne, wypelnienia otworow) Pomiar izolacyjnosci akustycznej – izolacyjnosc od dzwiekow powietrznych Delici konstrukce (stropy, steny, obvodove plaste, vyplne otvoru) Mereni zvukove izolace – vzduchova nepruzvucnost CSN EN ISO 717-1; CSN EN ISO 16283-1; CSN EN ISO 16283-3","search_en":"Separating elements (ceilings, walls, façades, openings infill) Measurement of sound insulation – airborne sound insulation ČSN EN ISO 717-1; ČSN EN ISO 16283-1; ČSN EN ISO 16283-3","search_zh":"分隔构件（楼板、墙体、外围护结构、门窗洞口填充） 隔声测量–空气声隔声 ČSN EN ISO 717-1; ČSN EN ISO 16283-1; ČSN EN ISO 16283-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b08c1d1b053952620f146100","lab_id":"69ad52a4de79e566650fd340","country":"CZ","accr_number":"1281","accr_body":"ČIA","row_label":"5","test_object":"Przegrody (podłogi i stropy)","test_object_en":"Separating elements (floors and ceilings)","test_object_zh":"分隔构件（地板和楼板）","test_object_cs":"Dělicí konstrukce (podlahy a stropy)","methodology":"Pomiar izolacyjności akustycznej – izolacyjność od dźwięków uderzeniowych","methodology_en":"Measurement of sound insulation – impact sound insulation","methodology_zh":"隔声测量–撞击声隔声","methodology_cs":"Měření zvukové izolace – kročejová neprůzvučnost","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności akustycznej – izolacyjność od dźwięków uderzeniowych","reference":"ČSN EN ISO 717-2; ČSN EN ISO 16283-2","norm_bases":["ČSN EN ISO 717-2","ČSN EN ISO 16283-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody (podłogi i stropy) Pomiar izolacyjności akustycznej – izolacyjność od dźwięków uderzeniowych Dělicí konstrukce (podlahy a stropy) Měření zvukové izolace – kročejová neprůzvučnost ČSN EN ISO 717-2; ČSN EN ISO 16283-2 Przegrody (podlogi i stropy) Pomiar izolacyjnosci akustycznej – izolacyjnosc od dzwiekow uderzeniowych Delici konstrukce (podlahy a stropy) Mereni zvukove izolace – krocejova nepruzvucnost CSN EN ISO 717-2; CSN EN ISO 16283-2","search_en":"Separating elements (floors and ceilings) Measurement of sound insulation – impact sound insulation ČSN EN ISO 717-2; ČSN EN ISO 16283-2","search_zh":"分隔构件（地板和楼板） 隔声测量–撞击声隔声 ČSN EN ISO 717-2; ČSN EN ISO 16283-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}