{"lab":{"_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","address":"Šmahova 1244/112, Slatina, 627 00 Brno","categories":["water","construction","environment"],"city":"Brno","imported_at":"2026-03-08T10:42:44.590Z","methods_count":92,"name":"GEOtest, a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1271_98_2026_CS.pdf","1271_98_2026_EN.pdf"],"scope_summary":"Pobieranie próbek, analizy analityczne i fizykochemiczne wód, gruntów, osadów, odpadów, osadów dennych, bioodpadów, powietrza, wyciągów oraz badania fizyko-mechaniczne gruntów, kruszyw i materiałów budowlanych, w zakresie określonym w załączniku do świadectwa.","search_text":"geotest, a.s. šmahova 1244/112, slatina, 627 00 brno 1271","status":"active","updated_at":"2026-03-08T14:52:09.800Z","valid_from":"","valid_until":"25-08-2028","website":"www.geotest.cz","location":{"type":"Point","coordinates":[16.6068,49.1951]},"email_confidence":"low","email_mx":false,"email_source":"https://www.geotest.cz","needs_review":true,"review_reason":"domena bez MX — zweryfikuj","map_coord":[49.170975,16.68284],"map_geo":"nominatim-street","certificate_date":"27.02.2026","certificate_no":"98/2026","certificate_replaces":"356/2025 z 10.07.2025","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pobieranie próbek, analizy analityczne i fizykochemiczne wód, gruntów, osadów, odpadów, osadów dennych, bioodpadów, powietrza, wyciągów oraz badania fizyko-mechaniczne gruntów, kruszyw i materiałów budowlanych, w zakresie określonym w załączniku do świadectwa.","en":"Sampling, analytical and physico-chemical analyses of water, soils, sludge, waste, sediments, biowaste, air, leachates and physico-mechanical testing of soils, aggregates and building materials to the extent as specified in the appendix to this Certificate.","zh":"水、土、污泥、废物、沉积物、生物废物、空气、浸出液的采样、分析和理化分析，以及土、集料和建筑材料的物理力学检测，范围见本证书附件。","cs":"Vzorkování, analytické a fyzikálně chemické analýzy vod, zemin, kalů, odpadů, sedimentů, bioodpadů, ovzduší, výluhů a fyzikálně mechanické zkoušení zemin, kameniva a stavebních materiálů, vymezené přílohou tohoto osvědčení."}],"flexible_scope":true,"flexible_scope_url":"https://analytickalaborator.cz/o-nas-laborator-v-brne/","has_en":true,"has_zh":true,"lab_division":"Laboratoria GEOtest","lab_division_cs":"Laboratoře GEOtest","lab_division_en":"GEOtest Laboratories","lab_division_zh":"GEOtest实验室","lab_locations":[{"code":null,"name":"GEOtest, a.s.","street":"Šmahova 1244/112, Slatina","postal_code":"627 00","city":"Brno","is_hq":true,"address":"Šmahova 1244/112, Slatina, 627 00 Brno","site":"62700|šmahova1244/112slatina"},{"code":null,"name":"Laboratoria analityczne","street":"Šmahova 1244/112, Slatina","postal_code":"627 00","city":"Brno","is_hq":false,"address":"Šmahova 1244/112, Slatina, 627 00 Brno","site":"62700|šmahova1244/112slatina"},{"code":null,"name":"Laboratoria mechaniki gruntów","street":"Šmahova 1244/112, Slatina","postal_code":"627 00","city":"Brno","is_hq":false,"address":"Šmahova 1244/112, Slatina, 627 00 Brno","site":"62700|šmahova1244/112slatina"}],"lab_locations_en":[{"code":null,"name":"GEOtest, a.s.","street":"Šmahova 1244/112, Slatina","postal_code":"627 00","city":"Brno","is_hq":true,"address":"Šmahova 1244/112, Slatina, 627 00 Brno","site":"62700|šmahova1244/112slatina"},{"code":null,"name":"Analytical laboratories","street":"Šmahova 1244/112, Slatina","postal_code":"627 00","city":"Brno","is_hq":false,"address":"Šmahova 1244/112, Slatina, 627 00 Brno","site":"62700|šmahova1244/112slatina"},{"code":null,"name":"Soil mechanics laboratories","street":"Šmahova 1244/112, Slatina","postal_code":"627 00","city":"Brno","is_hq":false,"address":"Šmahova 1244/112, Slatina, 627 00 Brno","site":"62700|šmahova1244/112slatina"}],"lab_locations_zh":[{"code":null,"name":"GEOtest, a.s.","street":"Šmahova 1244/112, Slatina","postal_code":"627 00","city":"Brno","is_hq":true,"address":"Šmahova 1244/112, Slatina, 627 00 Brno","site":"62700|šmahova1244/112slatina"},{"code":null,"name":"分析实验室","street":"Šmahova 1244/112, Slatina","postal_code":"627 00","city":"Brno","is_hq":false,"address":"Šmahova 1244/112, Slatina, 627 00 Brno","site":"62700|šmahova1244/112slatina"},{"code":null,"name":"土力学实验室","street":"Šmahova 1244/112, Slatina","postal_code":"627 00","city":"Brno","is_hq":false,"address":"Šmahova 1244/112, Slatina, 627 00 Brno","site":"62700|šmahova1244/112slatina"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"ČGÚ","pl":"Czeski Urząd Geologiczny","en":"Czech Geological Office","zh":"捷克地质局","cs":"Český geologický úřad"},{"abbr":"MŽP","pl":"Ministerstwo Środowiska Republiki Czeskiej","en":"Ministry of the Environment of the Czech Republic","zh":"捷克共和国环境部","cs":"Ministerstvo životního prostředí České republiky"},{"abbr":"MZ","pl":"Ministerstwo Zdrowia Republiki Czeskiej","en":"Ministry of Health of the Czech Republic","zh":"捷克共和国卫生部","cs":"Ministerstvo zdravotnictví České republiky"},{"abbr":"AA","pl":"Analiza nieorganiczna","en":"Inorganic analysis","zh":"无机分析","cs":"Anorganická analýza"},{"abbr":"OA","pl":"Analiza organiczna","en":"Organic analysis","zh":"有机分析","cs":"Organická analýza"},{"abbr":"ASA","pl":"Nieorganiczna analiza śladowa","en":"Inorganic trace analysis","zh":"无机痕量分析","cs":"Anorganická stopová analýza"},{"abbr":"TM","pl":"Pomiary terenowe","en":"Field measurement","zh":"现场测量","cs":"Terénní měření"},{"abbr":"OV","pl":"Ścieki","en":"Waste water","zh":"废水","cs":"Odpadní voda"},{"abbr":"TNV","pl":"Branżowa norma techniczna gospodarki wodnej","en":"Industry technical standard of water management","zh":"水务行业技术标准","cs":"Odvětvová technická norma vodního hospodářství"},{"abbr":"ASTM","pl":"Standard Methods for the Examination of Water and Waste Water (APHA, AWWA, WPCF), wyd. 14, Waszyngton 1975","en":"Standard Methods for the Examination of Water and Waste Water (APHA, AWWA, WPCF), 14th edition, Washington DC, 1975","zh":"水和废水检验标准方法（APHA、AWWA、WPCF），第14版，华盛顿，1975","cs":"American Standard Test Methods for the Examination of Water and Waste Water, American Public Health Assotiation, American Water Works Assotiation, Water Pollution Control Federation, 14. edition, Washington DC, 1975"},{"abbr":"US-EPA","pl":"Agencja Ochrony Środowiska Stanów Zjednoczonych","en":"Environmental Protection Agency of the United States of America","zh":"美国环境保护署","cs":"Environmental Protection Agency of the United States of America"},{"abbr":"DIN","pl":"Deutsches Institut für Normung (Niemiecki Instytut Normalizacyjny)","en":"Deutsches Institut für Normung (German Institute for Standardization)","zh":"德国标准化学会","cs":"Deutsches Institut fűr Normung"},{"abbr":"ORION","pl":"Instrukcja obsługi producenta ORION Research, Cambridge, Massachusetts, USA","en":"Operating manual of the manufacturer ORION Research, Cambridge, Massachusetts, U.S.A.","zh":"ORION Research公司操作手册（美国马萨诸塞州剑桥）","cs":"Operační manuál výrobce ORION Research, Cambridge, Massachusetts, U.S.A."},{"abbr":"PCB","pl":"Polichlorowane bifenyle","en":"Polychlorinated biphenyls","zh":"多氯联苯","cs":"Polychlorované bifenyly"},{"abbr":"OCP","pl":"Pestycydy chloroorganiczne","en":"Organochlorine pesticides","zh":"有机氯农药","cs":"Organochlorové pesticidy"},{"abbr":"PAU","pl":"Wielopierścieniowe węglowodory aromatyczne (WWA)","en":"Polyaromatic hydrocarbons (PAH)","zh":"多环芳烃","cs":"Polyaromatické uhlovodíky"},{"abbr":"TOC","pl":"Ogólny węgiel organiczny","en":"Total organic carbon","zh":"总有机碳","cs":"Celkový organický uhlík"},{"abbr":"TIC","pl":"Ogólny węgiel nieorganiczny","en":"Total inorganic carbon","zh":"总无机碳","cs":"Celkový anorganický uhlík"},{"abbr":"TC","pl":"Węgiel całkowity","en":"Total carbon","zh":"总碳","cs":"Celkový uhlík"},{"abbr":"DOC","pl":"Rozpuszczony węgiel organiczny","en":"Dissolved organic carbon","zh":"溶解性有机碳","cs":"Rozpuštěný organický uhlík"},{"abbr":"AOX","pl":"Adsorbowalne związki chloroorganiczne (halogeny organicznie związane)","en":"Adsorbable organically bound halogens","zh":"可吸附有机卤素","cs":"Adsorbovatelné organicky vázané halogeny"},{"abbr":"EOX","pl":"Ekstrahowalne halogeny organicznie związane","en":"Extractable organically bound halogens","zh":"可萃取有机卤素","cs":"Extrahovatelné organicky vázané halogeny"},{"abbr":"HPLC","pl":"Wysokosprawna chromatografia cieczowa","en":"High-performance liquid chromatography","zh":"高效液相色谱","cs":"Vysokoúčinná kapalinová chromatografie"},{"abbr":"GC","pl":"Chromatografia gazowa","en":"Gas chromatography","zh":"气相色谱","cs":"Plynová chromatografie"},{"abbr":"IR","pl":"Spektrometria w podczerwieni","en":"Infrared spectrometry","zh":"红外光谱","cs":"Infračervená spektrometrie"},{"abbr":"UV","pl":"Spektrometria w nadfiolecie","en":"Ultraviolet spectrometry","zh":"紫外光谱","cs":"Ultrafialová spektrometrie"},{"abbr":"MS","pl":"Spektrometria mas","en":"Mass spectrometry","zh":"质谱","cs":"Hmotnostní spektrometrie"},{"abbr":"ED-XRF","pl":"Rentgenowska spektrometria fluorescencyjna z dyspersją energii","en":"Energy-dispersive X-ray fluorescence","zh":"能量色散X射线荧光","cs":"Energiově disperzní rentgenová fluorescence"},{"abbr":"DAD","pl":"Detektor z matrycą diodową","en":"Diode array detector","zh":"二极管阵列检测器","cs":"Diode array detektor"},{"abbr":"FID","pl":"Detektor płomieniowo-jonizacyjny","en":"Flame ionisation detector","zh":"火焰离子化检测器","cs":"Plamenoionizační detektor"},{"abbr":"FLUD","pl":"Detektor fluorescencyjny","en":"Fluorescence detector","zh":"荧光检测器","cs":"Fluorescenční detektor"},{"abbr":"MSD","pl":"Detektor mas","en":"Mass selective detector","zh":"质量检测器","cs":"Hmotnostní detektor"},{"abbr":"TCD","pl":"Detektor cieplno-przewodnościowy","en":"Thermal conductivity detector","zh":"热导检测器","cs":"Tepelně vodivostní detektor"},{"abbr":"THM","pl":"Trihalometany","en":"Trihalomethanes","zh":"三卤甲烷","cs":"Trihalomethany"},{"abbr":"BTEX","pl":"Benzen, toluen, etylobenzen, ksyleny","en":"Benzene, toluene, ethylbenzene, xylenes","zh":"苯、甲苯、乙苯、二甲苯","cs":"Benzen, toluen, ethylbenzen, xyleny"},{"abbr":"ICP-OES","pl":"Optyczna spektrometria emisyjna z plazmą sprzężoną indukcyjnie","en":"Inductively coupled plasma optical emission spectrometry","zh":"电感耦合等离子体发射光谱","cs":"Optická emisní spektrometrie s indukčně vázaným plazmatem"},{"abbr":"ORP","pl":"Potencjał oksydacyjno-redukcyjny","en":"Oxidation-reduction potential","zh":"氧化还原电位","cs":"Oxidačně-redukční potenciál"},{"abbr":"TOL","pl":"Lotne związki organiczne","en":"Volatile organic compounds","zh":"挥发性有机物","cs":"Těkavé organické látky"},{"abbr":"ClU","pl":"Węglowodory chlorowane","en":"Chlorinated hydrocarbons","zh":"氯代烃","cs":"Chlorované uhlovodíky"},{"abbr":"CFA","pl":"Analiza przepływowa ciągła","en":"Continuous flow analysis","zh":"连续流动分析","cs":"Kontinuální průtoková analýza"}],"scope_notes":[{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The laboratory is competent to carry out standalone sampling.","zh":"实验室有能力独立进行采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."}],"source_lang":"cs","source_pdf_sha256":"6afd672c0c9d8539fa6f2782b8dd39abd481f89d58fb60136cd7c5a9b45fbadb","source_pdf_url":"https://www.cai.cz/OA/pdf/98_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/98_2026_EN.pdf"},"methods":[{"_id":"1b7b79a608b750527eeb6689","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"1","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"pH测定（电位法）","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"SOP AL-01 (ČSN ISO 10523)","norm_bases":["SOP AL-01","ČSN ISO 10523"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny Oznaczanie pH metodą potencjometryczną Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok Stanovení pH potenciometricky SOP AL-01 (ČSN ISO 10523) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny Oznaczanie pH metoda potencjometryczna Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok Stanoveni pH potenciometricky SOP AL-01 (CSN ISO 10523)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution Determination of pH by potentiometry SOP AL-01 (ČSN ISO 10523)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液 pH测定（电位法） SOP AL-01 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2b1bc3035cb9789c50e42c4d","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"2","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok","methodology":"Oznaczanie przewodności elektrycznej właściwej","methodology_en":"Determination of electrical conductivity","methodology_zh":"电导率测定","methodology_cs":"Stanovení elektrické konduktivity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej właściwej","reference":"SOP AL-02 (ČSN EN 27888)","norm_bases":["SOP AL-02","ČSN EN 27888"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny Oznaczanie przewodności elektrycznej właściwej Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok Stanovení elektrické konduktivity SOP AL-02 (ČSN EN 27888) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny Oznaczanie przewodnosci elektrycznej wlasciwej Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok Stanoveni elektricke konduktivity SOP AL-02 (CSN EN 27888)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution Determination of electrical conductivity SOP AL-02 (ČSN EN 27888)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液 电导率测定 SOP AL-02 (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5b14ffe7b1573b75731f95a5","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"3","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok","methodology":"Oznaczanie zdolności neutralizacji kwasów (KNK) metodą miareczkową","methodology_en":"Determination of acid neutralizing capacity (ANC) by titration","methodology_zh":"酸中和能力测定（滴定法）","methodology_cs":"Stanovení kyselinové neutralizační kapacity (KNK) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zdolności neutralizacji kwasów (KNK) metodą miareczkową","reference":"SOP AL-03 (ČSN EN ISO 9963-1)","norm_bases":["SOP AL-03","ČSN EN ISO 9963-1"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny Oznaczanie zdolności neutralizacji kwasów (KNK) metodą miareczkową Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok Stanovení kyselinové neutralizační kapacity (KNK) titračně SOP AL-03 (ČSN EN ISO 9963-1) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny Oznaczanie zdolnosci neutralizacji kwasow (KNK) metoda miareczkowa Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok Stanoveni kyselinove neutralizacni kapacity (KNK) titracne SOP AL-03 (CSN EN ISO 9963-1)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution Determination of acid neutralizing capacity (ANC) by titration SOP AL-03 (ČSN EN ISO 9963-1)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液 酸中和能力测定（滴定法） SOP AL-03 (ČSN EN ISO 9963-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bd07e16340517dd7d7518c88","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"4","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok","methodology":"Oznaczanie chlorków metodą miareczkowania argentometrycznego","methodology_en":"Determination of chloride - Silver nitrate titration","methodology_zh":"氯化物测定（银量滴定法）","methodology_cs":"Stanovení chloridů argentometrickou titrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków metodą miareczkowania argentometrycznego","reference":"SOP AL-04 (ČSN ISO 9297)","norm_bases":["SOP AL-04","ČSN ISO 9297"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane | Roztwór absorpcyjny – roztwór absorpcyjny z poboru emisji","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water | Absorption solution – absorption solution from emission sampling","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水 | 吸收液–排放采样吸收液","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní | Absorpční roztok – absorpční roztok z odběru emisí","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny Oznaczanie chlorków metodą miareczkowania argentometrycznego Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok Stanovení chloridů argentometrickou titrací SOP AL-04 (ČSN ISO 9297) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny, roztwor absorpcyjny Oznaczanie chlorkow metoda miareczkowania argentometrycznego Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok, absorpcni roztok Stanoveni chloridu argentometrickou titraci SOP AL-04 (CSN ISO 9297)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution Determination of chloride - Silver nitrate titration SOP AL-04 (ČSN ISO 9297)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液 氯化物测定（银量滴定法） SOP AL-04 (ČSN ISO 9297)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6ad09bd1cac9514cad910e74","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"5","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok","methodology":"Oznaczanie azotanów metodą spektrofotometryczną i azotu azotanowego obliczeniowo z wartości zmierzonych","methodology_en":"Determination of nitrate by spectrophotometry and nitrate nitrogen by calculation from measured values","methodology_zh":"硝酸盐测定（分光光度法）及由测量值计算硝酸盐氮","methodology_cs":"Stanovení dusičnanů spektrofotometricky a dusičnanového dusíků výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotanów metodą spektrofotometryczną i azotu azotanowego obliczeniowo z wartości zmierzonych","reference":"SOP AL-05 (ČSN ISO 7890-3)","norm_bases":["SOP AL-05","ČSN ISO 7890-3"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane | Roztwór absorpcyjny – roztwór absorpcyjny z poboru emisji","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water | Absorption solution – absorption solution from emission sampling","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水 | 吸收液–排放采样吸收液","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní | Absorpční roztok – absorpční roztok z odběru emisí","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny Oznaczanie azotanów metodą spektrofotometryczną i azotu azotanowego obliczeniowo z wartości zmierzonych Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok Stanovení dusičnanů spektrofotometricky a dusičnanového dusíků výpočtem z naměřených hodnot SOP AL-05 (ČSN ISO 7890-3) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny, roztwor absorpcyjny Oznaczanie azotanow metoda spektrofotometryczna i azotu azotanowego obliczeniowo z wartosci zmierzonych Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok, absorpcni roztok Stanoveni dusicnanu spektrofotometricky a dusicnanoveho dusiku vypoctem z namerenych hodnot SOP AL-05 (CSN ISO 7890-3)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution Determination of nitrate by spectrophotometry and nitrate nitrogen by calculation from measured values SOP AL-05 (ČSN ISO 7890-3)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液 硝酸盐测定（分光光度法）及由测量值计算硝酸盐氮 SOP AL-05 (ČSN ISO 7890-3)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"52f717a6306a9e84a59cab2c","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"6","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok","methodology":"Oznaczanie fluorków metodą elektrochemiczną","methodology_en":"Determination of fluorides by electrochemical method","methodology_zh":"氟化物测定（电化学法）","methodology_cs":"Stanovení fluoridů elektrochemicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fluorków metodą elektrochemiczną","reference":"SOP AL-06 (ČSN ISO 10359-1)","norm_bases":["SOP AL-06","ČSN ISO 10359-1"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane | Roztwór absorpcyjny – roztwór absorpcyjny z poboru emisji","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water | Absorption solution – absorption solution from emission sampling","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水 | 吸收液–排放采样吸收液","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní | Absorpční roztok – absorpční roztok z odběru emisí","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny Oznaczanie fluorków metodą elektrochemiczną Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok Stanovení fluoridů elektrochemicky SOP AL-06 (ČSN ISO 10359-1) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny, roztwor absorpcyjny Oznaczanie fluorkow metoda elektrochemiczna Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok, absorpcni roztok Stanoveni fluoridu elektrochemicky SOP AL-06 (CSN ISO 10359-1)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution Determination of fluorides by electrochemical method SOP AL-06 (ČSN ISO 10359-1)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液 氟化物测定（电化学法） SOP AL-06 (ČSN ISO 10359-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eef99d4cc11ac1771d73672a","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"7","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok","methodology":"Oznaczanie jonów amonowych metodą spektrofotometryczną, azotu amonowego i wolnego amoniaku obliczeniowo z wartości zmierzonych","methodology_en":"Determination of ammonium by spectrophotometry, determination of ammonia nitrogen and free ammonia by calculation from measured values","methodology_zh":"铵离子测定（分光光度法），由测量值计算氨氮和游离氨","methodology_cs":"Stanovení amonných iontů spektrofotometricky, stanovení amoniakálního dusíku a volného amoniaku výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych metodą spektrofotometryczną, azotu amonowego i wolnego amoniaku obliczeniowo z wartości zmierzonych","reference":"SOP AL-07 (ČSN 83 0530:1978, část 26)","norm_bases":["SOP AL-07","ČSN 83 0530:1978, část 26"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane | Roztwór absorpcyjny – roztwór absorpcyjny z poboru emisji","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water | Absorption solution – absorption solution from emission sampling","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水 | 吸收液–排放采样吸收液","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní | Absorpční roztok – absorpční roztok z odběru emisí","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny Oznaczanie jonów amonowych metodą spektrofotometryczną, azotu amonowego i wolnego amoniaku obliczeniowo z wartości zmierzonych Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok Stanovení amonných iontů spektrofotometricky, stanovení amoniakálního dusíku a volného amoniaku výpočtem z naměřených hodnot SOP AL-07 (ČSN 83 0530:1978, část 26) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny, roztwor absorpcyjny Oznaczanie jonow amonowych metoda spektrofotometryczna, azotu amonowego i wolnego amoniaku obliczeniowo z wartosci zmierzonych Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok, absorpcni roztok Stanoveni amonnych iontu spektrofotometricky, stanoveni amoniakalniho dusiku a volneho amoniaku vypoctem z namerenych hodnot SOP AL-07 (CSN 83 0530:1978, cast 26)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution Determination of ammonium by spectrophotometry, determination of ammonia nitrogen and free ammonia by calculation from measured values SOP AL-07 (ČSN 83 0530:1978, část 26)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液 铵离子测定（分光光度法），由测量值计算氨氮和游离氨 SOP AL-07 (ČSN 83 0530:1978, část 26)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d32df94f76e606525c0c894d","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"8","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok","methodology":"Oznaczanie azotynów metodą spektrofotometryczną, azotu azotynowego i azotu nieorganicznego obliczeniowo z wartości zmierzonych","methodology_en":"Determination of nitrite by spectrophotometry, determination of nitrite nitrogen and inorganic nitrogen by calculation from measured values","methodology_zh":"亚硝酸盐测定（分光光度法），由测量值计算亚硝酸盐氮和无机氮","methodology_cs":"Stanovení dusitanů spektrofotometricky, stanovení dusitanového dusíku a anorganického dusíku výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotynów metodą spektrofotometryczną, azotu azotynowego i azotu nieorganicznego obliczeniowo z wartości zmierzonych","reference":"SOP AL-08 (ČSN EN 26777)","norm_bases":["SOP AL-08","ČSN EN 26777"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane | Roztwór absorpcyjny – roztwór absorpcyjny z poboru emisji","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water | Absorption solution – absorption solution from emission sampling","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水 | 吸收液–排放采样吸收液","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní | Absorpční roztok – absorpční roztok z odběru emisí","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny Oznaczanie azotynów metodą spektrofotometryczną, azotu azotynowego i azotu nieorganicznego obliczeniowo z wartości zmierzonych Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok Stanovení dusitanů spektrofotometricky, stanovení dusitanového dusíku a anorganického dusíku výpočtem z naměřených hodnot SOP AL-08 (ČSN EN 26777) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny, roztwor absorpcyjny Oznaczanie azotynow metoda spektrofotometryczna, azotu azotynowego i azotu nieorganicznego obliczeniowo z wartosci zmierzonych Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok, absorpcni roztok Stanoveni dusitanu spektrofotometricky, stanoveni dusitanoveho dusiku a anorganickeho dusiku vypoctem z namerenych hodnot SOP AL-08 (CSN EN 26777)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution Determination of nitrite by spectrophotometry, determination of nitrite nitrogen and inorganic nitrogen by calculation from measured values SOP AL-08 (ČSN EN 26777)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液 亚硝酸盐测定（分光光度法），由测量值计算亚硝酸盐氮和无机氮 SOP AL-08 (ČSN EN 26777)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"685def9162a0dd0d3a567b15","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"9","test_object":"Woda przeznaczona do spożycia, wody podziemne i powierzchniowe","test_object_en":"Drinking, ground and surface water","test_object_zh":"饮用水、地下水和地表水","test_object_cs":"Pitná, podzemní a povrchová voda","methodology":"Oznaczanie agresywnego ditlenku węgla próbą marmurową wg Heyera metodą miareczkową","methodology_en":"Determination of aggressive carbon dioxide by Heyer's marble test using titration","methodology_zh":"侵蚀性二氧化碳测定（Heyer大理石试验，滴定法）","methodology_cs":"Stanovení agresivního oxidu uhličitého mramorovou zkouškou podle Heyera titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie agresywnego ditlenku węgla próbą marmurową wg Heyera metodą miareczkową","reference":"SOP AL-58 (ČSN 75 7373)","norm_bases":["SOP AL-58","ČSN 75 7373"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Ground water – mineral, spa, mine water","note_zh":"地下水–矿泉水、温泉水、矿井水","note_cs":"Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne i powierzchniowe Oznaczanie agresywnego ditlenku węgla próbą marmurową wg Heyera metodą miareczkową Pitná, podzemní a povrchová voda Stanovení agresivního oxidu uhličitého mramorovou zkouškou podle Heyera titračně SOP AL-58 (ČSN 75 7373) Woda przeznaczona do spozycia, wody podziemne i powierzchniowe Oznaczanie agresywnego ditlenku wegla proba marmurowa wg Heyera metoda miareczkowa Pitna, podzemni a povrchova voda Stanoveni agresivniho oxidu uhliciteho mramorovou zkouskou podle Heyera titracne SOP AL-58 (CSN 75 7373)","search_en":"Drinking, ground and surface water Determination of aggressive carbon dioxide by Heyer's marble test using titration SOP AL-58 (ČSN 75 7373)","search_zh":"饮用水、地下水和地表水 侵蚀性二氧化碳测定（Heyer大理石试验，滴定法） SOP AL-58 (ČSN 75 7373)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ad759a67dfdaca2b4e70e33a","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"10","test_object":"Woda przeznaczona do spożycia, wody podziemne i powierzchniowe, roztwór wodny","test_object_en":"Drinking, ground and surface water, aqueous solution","test_object_zh":"饮用水、地下水和地表水、水溶液","test_object_cs":"Pitná, podzemní a povrchová voda, vodný roztok","methodology":"Oznaczanie jodków metodą potencjometryczną","methodology_en":"Determination of iodide by potentiometry","methodology_zh":"碘化物测定（电位法）","methodology_cs":"Stanovení jodidů potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jodków metodą potencjometryczną","reference":"SOP AL-10 (návod firmy HANNA Instruments)","norm_bases":["SOP AL-10","návod firmy HANNA Instruments"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Ground water – mineral, spa, mine water","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne i powierzchniowe, roztwór wodny Oznaczanie jodków metodą potencjometryczną Pitná, podzemní a povrchová voda, vodný roztok Stanovení jodidů potenciometricky SOP AL-10 (návod firmy HANNA Instruments) Woda przeznaczona do spozycia, wody podziemne i powierzchniowe, roztwor wodny Oznaczanie jodkow metoda potencjometryczna Pitna, podzemni a povrchova voda, vodny roztok Stanoveni jodidu potenciometricky SOP AL-10 (navod firmy HANNA Instruments)","search_en":"Drinking, ground and surface water, aqueous solution Determination of iodide by potentiometry SOP AL-10 (návod firmy HANNA Instruments)","search_zh":"饮用水、地下水和地表水、水溶液 碘化物测定（电位法） SOP AL-10 (návod firmy HANNA Instruments)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0911f4f11a013ca5af3d4a85","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"11","test_object":"Woda przeznaczona do spożycia, wody podziemne i powierzchniowe","test_object_en":"Drinking, ground and surface water","test_object_zh":"饮用水、地下水和地表水","test_object_cs":"Pitná, podzemní a povrchová voda","methodology":"Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (ChZT-Mn)","methodology_en":"Determination of chemical oxygen demand with permanganate (COD-Mn)","methodology_zh":"高锰酸盐化学需氧量（COD-Mn）测定","methodology_cs":"Stanovení chemické spotřeby kyslíku manganistanem (CHSK-Mn)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (ChZT-Mn)","reference":"SOP AL-11 (ČSN EN ISO 8467)","norm_bases":["SOP AL-11","ČSN EN ISO 8467"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Ground water – mineral, spa, mine water","note_zh":"地下水–矿泉水、温泉水、矿井水","note_cs":"Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne i powierzchniowe Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (ChZT-Mn) Pitná, podzemní a povrchová voda Stanovení chemické spotřeby kyslíku manganistanem (CHSK-Mn) SOP AL-11 (ČSN EN ISO 8467) Woda przeznaczona do spozycia, wody podziemne i powierzchniowe Oznaczanie chemicznego zapotrzebowania na tlen metoda nadmanganianowa (ChZT-Mn) Pitna, podzemni a povrchova voda Stanoveni chemicke spotreby kysliku manganistanem (CHSK-Mn) SOP AL-11 (CSN EN ISO 8467)","search_en":"Drinking, ground and surface water Determination of chemical oxygen demand with permanganate (COD-Mn) SOP AL-11 (ČSN EN ISO 8467)","search_zh":"饮用水、地下水和地表水 高锰酸盐化学需氧量（COD-Mn）测定 SOP AL-11 (ČSN EN ISO 8467)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c2f2d88f0530d759d6782a17","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"12","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok","methodology":"Oznaczanie anionów metodą chromatografii jonowej","methodology_en":"Determination of anions by ion chromatography","methodology_zh":"阴离子测定（离子色谱法）","methodology_cs":"Stanovení aniontů iontovou chromatografií","parameters":[{"name":"Chloryny","range":""},{"name":"chlorany","range":""},{"name":"bromiany","range":""},{"name":"fluorki","range":""},{"name":"siarczany","range":""},{"name":"fosforany","range":""},{"name":"azotyny","range":""},{"name":"azotany","range":""},{"name":"chlorki","range":""}],"parameters_en":[{"name":"Chlorites","range":""},{"name":"chlorates","range":""},{"name":"bromates","range":""},{"name":"fluorides","range":""},{"name":"sulphates","range":""},{"name":"phosphates","range":""},{"name":"nitrites","range":""},{"name":"nitrates","range":""},{"name":"chlorides","range":""}],"parameters_zh":[{"name":"亚氯酸盐","range":""},{"name":"氯酸盐","range":""},{"name":"溴酸盐","range":""},{"name":"氟化物","range":""},{"name":"硫酸盐","range":""},{"name":"磷酸盐","range":""},{"name":"亚硝酸盐","range":""},{"name":"硝酸盐","range":""},{"name":"氯化物","range":""}],"parameters_cs":[{"name":"Chloritany","range":""},{"name":"chlorečnany","range":""},{"name":"bromičnany","range":""},{"name":"fluoridy","range":""},{"name":"sírany","range":""},{"name":"fosforečnany","range":""},{"name":"dusitany","range":""},{"name":"dusičnany","range":""},{"name":"chloridy","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["azot azotynowy","azot azotanowy","tlenek fosforu(V)","fosfor fosforanowy","suma chlorynów i chloranów obliczeniowo z wartości zmierzonych"],"computed_en":["nitrite nitrogen","nitrate nitrogen","phosphorus pentoxide","phosphate phosphorus","sum of chlorites and chlorates by calculation from measured values"],"computed_zh":["亚硝酸盐氮","硝酸盐氮","五氧化二磷","磷酸盐磷","由测量值计算亚氯酸盐和氯酸盐总和"],"computed_cs":["dusitanový dusík","dusičnanový dusík","oxid fosforečný","fosforečnanový fosfor","suma chloritanů a chlorečnanů výpočtem z naměřených hodnot"],"activity":"Oznaczanie anionów metodą chromatografii jonowej\nZakres:\nChloryny\nchlorany\nbromiany\nfluorki\nsiarczany\nfosforany\nazotyny\nazotany\nchlorki","reference":"SOP AL-12 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)","norm_bases":["SOP AL-12","ČSN EN ISO 10304-1","ČSN EN ISO 10304-4","ČSN EN ISO 15061"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny Oznaczanie anionów metodą chromatografii jonowej Chloryny  chlorany  bromiany  fluorki  siarczany  fosforany  azotyny  azotany  chlorki  azot azotynowy azot azotanowy tlenek fosforu(V) fosfor fosforanowy suma chlorynów i chloranów obliczeniowo z wartości zmierzonych Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok Stanovení aniontů iontovou chromatografií Chloritany  chlorečnany  bromičnany  fluoridy  sírany  fosforečnany  dusitany  dusičnany  chloridy  dusitanový dusík dusičnanový dusík oxid fosforečný fosforečnanový fosfor suma chloritanů a chlorečnanů výpočtem z naměřených hodnot SOP AL-12 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny Oznaczanie anionow metoda chromatografii jonowej Chloryny  chlorany  bromiany  fluorki  siarczany  fosforany  azotyny  azotany  chlorki  azot azotynowy azot azotanowy tlenek fosforu(V) fosfor fosforanowy suma chlorynow i chloranow obliczeniowo z wartosci zmierzonych Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok Stanoveni aniontu iontovou chromatografii Chloritany  chlorecnany  bromicnany  fluoridy  sirany  fosforecnany  dusitany  dusicnany  chloridy  dusitanovy dusik dusicnanovy dusik oxid fosforecny fosforecnanovy fosfor suma chloritanu a chlorecnanu vypoctem z namerenych hodnot SOP AL-12 (CSN EN ISO 10304-1; CSN EN ISO 10304-4; CSN EN ISO 15061)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution Determination of anions by ion chromatography Chlorites  chlorates  bromates  fluorides  sulphates  phosphates  nitrites  nitrates  chlorides  nitrite nitrogen nitrate nitrogen phosphorus pentoxide phosphate phosphorus sum of chlorites and chlorates by calculation from measured values SOP AL-12 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液 阴离子测定（离子色谱法） 亚氯酸盐  氯酸盐  溴酸盐  氟化物  硫酸盐  磷酸盐  亚硝酸盐  硝酸盐  氯化物  亚硝酸盐氮 硝酸盐氮 五氧化二磷 磷酸盐磷 由测量值计算亚氯酸盐和氯酸盐总和 SOP AL-12 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eb77766e5d74097c24820ba2","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"13","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok","methodology":"Oznaczanie cyjanków ogólnych metodą spektrofotometryczną","methodology_en":"Determination of total cyanide by spectrophotometry","methodology_zh":"总氰化物测定（分光光度法）","methodology_cs":"Stanovení veškerých kyanidů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cyjanków ogólnych metodą spektrofotometryczną","reference":"SOP AL-13 (ČSN 75 7415; ASTM 413 A; ASTM 413 B; ASTM 413 D)","norm_bases":["SOP AL-13","ČSN 75 7415","ASTM 413 A","ASTM 413 B","ASTM 413 D"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane | Roztwór absorpcyjny – roztwór absorpcyjny z poboru emisji","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water | Absorption solution – absorption solution from emission sampling","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水 | 吸收液–排放采样吸收液","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní | Absorpční roztok – absorpční roztok z odběru emisí","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny Oznaczanie cyjanków ogólnych metodą spektrofotometryczną Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok Stanovení veškerých kyanidů spektrofotometricky SOP AL-13 (ČSN 75 7415; ASTM 413 A; ASTM 413 B; ASTM 413 D) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny, roztwor absorpcyjny Oznaczanie cyjankow ogolnych metoda spektrofotometryczna Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok, absorpcni roztok Stanoveni veskerych kyanidu spektrofotometricky SOP AL-13 (CSN 75 7415; ASTM 413 A; ASTM 413 B; ASTM 413 D)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution Determination of total cyanide by spectrophotometry SOP AL-13 (ČSN 75 7415; ASTM 413 A; ASTM 413 B; ASTM 413 D)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液 总氰化物测定（分光光度法） SOP AL-13 (ČSN 75 7415; ASTM 413 A; ASTM 413 B; ASTM 413 D)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"51da4760e98fe4bc9711427f","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"15","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok","methodology":"Oznaczanie cyjanków łatwo uwalnialnych metodą spektrofotometryczną","methodology_en":"Determination of easily liberatable cyanides by spectrophotometry","methodology_zh":"易释放氰化物测定（分光光度法）","methodology_cs":"Stanovení snadno uvolnitelných kyanidů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cyjanków łatwo uwalnialnych metodą spektrofotometryczną","reference":"SOP AL-14 (ČSN ISO 6703-2; ASTM 413 A; ASTM 413 D)","norm_bases":["SOP AL-14","ČSN ISO 6703-2","ASTM 413 A","ASTM 413 D"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny Oznaczanie cyjanków łatwo uwalnialnych metodą spektrofotometryczną Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok Stanovení snadno uvolnitelných kyanidů spektrofotometricky SOP AL-14 (ČSN ISO 6703-2; ASTM 413 A; ASTM 413 D) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny Oznaczanie cyjankow latwo uwalnialnych metoda spektrofotometryczna Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok Stanoveni snadno uvolnitelnych kyanidu spektrofotometricky SOP AL-14 (CSN ISO 6703-2; ASTM 413 A; ASTM 413 D)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution Determination of easily liberatable cyanides by spectrophotometry SOP AL-14 (ČSN ISO 6703-2; ASTM 413 A; ASTM 413 D)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液 易释放氰化物测定（分光光度法） SOP AL-14 (ČSN ISO 6703-2; ASTM 413 A; ASTM 413 D)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"24040a1fe69a6e4c445d6b99","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"17","test_object":"Woda przeznaczona do spożycia","test_object_en":"Drinking water","test_object_zh":"饮用水","test_object_cs":"Pitná voda","methodology":"Orientacyjne oznaczanie zapachu i smaku","methodology_en":"Preliminary determination of odour and taste","methodology_zh":"气味和味道初步测定","methodology_cs":"Orientační stanovení pachu a chuti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Orientacyjne oznaczanie zapachu i smaku","reference":"SOP AL-15 (ČSN 75 7340)","norm_bases":["SOP AL-15","ČSN 75 7340"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda przeznaczona do spożycia Orientacyjne oznaczanie zapachu i smaku Pitná voda Orientační stanovení pachu a chuti SOP AL-15 (ČSN 75 7340) Woda przeznaczona do spozycia Orientacyjne oznaczanie zapachu i smaku Pitna voda Orientacni stanoveni pachu a chuti SOP AL-15 (CSN 75 7340)","search_en":"Drinking water Preliminary determination of odour and taste SOP AL-15 (ČSN 75 7340)","search_zh":"饮用水 气味和味道初步测定 SOP AL-15 (ČSN 75 7340)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5bb8bd55f67a2c71e5c89e34","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"18","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok","methodology":"Oznaczanie pierwiastków metodą ICP-OES","methodology_en":"Determination of elements by ICP-OES method","methodology_zh":"元素测定（ICP-OES法）","methodology_cs":"Stanovení prvků metodou ICP-OES","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Lit (Li)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Fosfor ogólny (Pcelk.)","range":""},{"name":"Siarka ogólna (Scelk.)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Sód (Na)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Krzem (Si)","range":""},{"name":"Stront (Sr)","range":""},{"name":"Tal (Tl)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Lithium (Li)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Total phosphorus (Pcelk.)","range":""},{"name":"Total sulphur (Scelk.)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Silicon (Si)","range":""},{"name":"Strontium (Sr)","range":""},{"name":"Thallium (Tl)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"锂（Li）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"锑（Sb）","range":""},{"name":"硒（Se）","range":""},{"name":"锡（Sn）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"总磷（Pcelk.）","range":""},{"name":"总硫（Scelk.）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""},{"name":"钠（Na）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"硅（Si）","range":""},{"name":"锶（Sr）","range":""},{"name":"铊（Tl）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"Li","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Sb","range":""},{"name":"Se","range":""},{"name":"Sn","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"Pcelk.","range":""},{"name":"Scelk.","range":""},{"name":"V","range":""},{"name":"Zn","range":""},{"name":"Na","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Si","range":""},{"name":"Sr","range":""},{"name":"Tl","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["krzemiany jako SiO2","twardość ogólna (Ca + Mg)","twardość jako CaCO3 i siarczany obliczeniowo z wartości zmierzonych"],"computed_en":["silicates as SiO2","total hardness (Ca + Mg)","hardness as CaCO3 and sulphates by calculation from measured values"],"computed_zh":["以SiO2计的硅酸盐","总硬度（Ca + Mg）","由测量值计算以CaCO3计的硬度和硫酸盐"],"computed_cs":["křemičitany jako SiO2","celková tvrdost (Ca + Mg)","tvrdost jako CaCO3 a sírany výpočtem z naměřených hodnot"],"activity":"Oznaczanie pierwiastków metodą ICP-OES\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nLit (Li)\nMangan (Mn)\nMolibden (Mo)\nAntymon (Sb)\nSelen (Se)\nCyna (Sn)\nNikiel (Ni)\nOłów (Pb)\nFosfor ogólny (Pcelk.)\nSiarka ogólna (Scelk.)\nWanad (V)\nCynk (Zn)\nSód (Na)\nPotas (K)\nMagnez (Mg)\nKrzem (Si)\nStront (Sr)\nTal (Tl)","reference":"SOP AL-16 (ČSN EN ISO 11885)","norm_bases":["SOP AL-16","ČSN EN ISO 11885"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane | Roztwór absorpcyjny – roztwór absorpcyjny z poboru emisji","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water | Absorption solution – absorption solution from emission sampling","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水 | 吸收液–排放采样吸收液","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní | Absorpční roztok – absorpční roztok z odběru emisí","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny Oznaczanie pierwiastków metodą ICP-OES Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Lit (Li)  Mangan (Mn)  Molibden (Mo)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Nikiel (Ni)  Ołów (Pb)  Fosfor ogólny (Pcelk.)  Siarka ogólna (Scelk.)  Wanad (V)  Cynk (Zn)  Sód (Na)  Potas (K)  Magnez (Mg)  Krzem (Si)  Stront (Sr)  Tal (Tl)  krzemiany jako SiO2 twardość ogólna (Ca + Mg) twardość jako CaCO3 i siarczany obliczeniowo z wartości zmierzonych Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok Stanovení prvků metodou ICP-OES Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  Li  Mn  Mo  Sb  Se  Sn  Ni  Pb  Pcelk.  Scelk.  V  Zn  Na  K  Mg  Si  Sr  Tl  křemičitany jako SiO2 celková tvrdost (Ca + Mg) tvrdost jako CaCO3 a sírany výpočtem z naměřených hodnot SOP AL-16 (ČSN EN ISO 11885) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny, roztwor absorpcyjny Oznaczanie pierwiastkow metoda ICP-OES Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Lit (Li)  Mangan (Mn)  Molibden (Mo)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Nikiel (Ni)  Olow (Pb)  Fosfor ogolny (Pcelk.)  Siarka ogolna (Scelk.)  Wanad (V)  Cynk (Zn)  Sod (Na)  Potas (K)  Magnez (Mg)  Krzem (Si)  Stront (Sr)  Tal (Tl)  krzemiany jako SiO2 twardosc ogolna (Ca + Mg) twardosc jako CaCO3 i siarczany obliczeniowo z wartosci zmierzonych Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok, absorpcni roztok Stanoveni prvku metodou ICP-OES Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  Li  Mn  Mo  Sb  Se  Sn  Ni  Pb  Pcelk.  Scelk.  V  Zn  Na  K  Mg  Si  Sr  Tl  kremicitany jako SiO2 celkova tvrdost (Ca + Mg) tvrdost jako CaCO3 a sirany vypoctem z namerenych hodnot SOP AL-16 (CSN EN ISO 11885)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution Determination of elements by ICP-OES method Silver (Ag)  Aluminium (Al)  Arsenic (As)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Lithium (Li)  Manganese (Mn)  Molybdenum (Mo)  Antimony (Sb)  Selenium (Se)  Tin (Sn)  Nickel (Ni)  Lead (Pb)  Total phosphorus (Pcelk.)  Total sulphur (Scelk.)  Vanadium (V)  Zinc (Zn)  Sodium (Na)  Potassium (K)  Magnesium (Mg)  Silicon (Si)  Strontium (Sr)  Thallium (Tl)  silicates as SiO2 total hardness (Ca + Mg) hardness as CaCO3 and sulphates by calculation from measured values SOP AL-16 (ČSN EN ISO 11885)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液 元素测定（ICP-OES法） 银（Ag）  铝（Al）  砷（As）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  锂（Li）  锰（Mn）  钼（Mo）  锑（Sb）  硒（Se）  锡（Sn）  镍（Ni）  铅（Pb）  总磷（Pcelk.）  总硫（Scelk.）  钒（V）  锌（Zn）  钠（Na）  钾（K）  镁（Mg）  硅（Si）  锶（Sr）  铊（Tl）  以SiO2计的硅酸盐 总硬度（Ca + Mg） 由测量值计算以CaCO3计的硬度和硫酸盐 SOP AL-16 (ČSN EN ISO 11885)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3bb62a120abaf0110a8420fa","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"19","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie pierwiastków metodą ICP-OES","methodology_en":"Determination of selected elements by ICP-OES method","methodology_zh":"所选元素测定（ICP-OES法）","methodology_cs":"Stanovení prvků metodou ICP-OES","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Siarka (S)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Sulphur (S)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"砷（As）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"锡（Sn）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"磷（P）","range":""},{"name":"硫（S）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"As","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Sn","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"P","range":""},{"name":"S","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków metodą ICP-OES\nZakres:\nSrebro (Ag)\nArsen (As)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nMangan (Mn)\nMolibden (Mo)\nCyna (Sn)\nNikiel (Ni)\nOłów (Pb)\nFosfor (P)\nSiarka (S)\nWanad (V)\nCynk (Zn)","reference":"SOP AL-16A (ČSN EN ISO 22036)","norm_bases":["SOP AL-16A","ČSN EN ISO 22036"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Matryce stałe – różne rodzaje próbek stałych gruntów, osadów dennych, kompostów, osadów, odpadów, gleby, konstrukcji budowlanych","note_en":"Solid matrices – various types of solid samples of soils, sediments, composts, sludge, waste, soil, building structures","note_zh":"固体基质–土、沉积物、堆肥、污泥、废物、土壤、建筑结构等各类固体样品","note_cs":"Pevné matrice – různé typy pevných vzorků zemin, sedimentů, kompostů, kalů, odpadů, půdy, stavebních konstrukcí","search_text":"Matryce stałe Oznaczanie pierwiastków metodą ICP-OES Srebro (Ag)  Arsen (As)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Mangan (Mn)  Molibden (Mo)  Cyna (Sn)  Nikiel (Ni)  Ołów (Pb)  Fosfor (P)  Siarka (S)  Wanad (V)  Cynk (Zn)  Pevné matrice Stanovení prvků metodou ICP-OES Ag  As  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  Mn  Mo  Sn  Ni  Pb  P  S  V  Zn  SOP AL-16A (ČSN EN ISO 22036) Matryce stale Oznaczanie pierwiastkow metoda ICP-OES Srebro (Ag)  Arsen (As)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Mangan (Mn)  Molibden (Mo)  Cyna (Sn)  Nikiel (Ni)  Olow (Pb)  Fosfor (P)  Siarka (S)  Wanad (V)  Cynk (Zn)  Pevne matrice Stanoveni prvku metodou ICP-OES Ag  As  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  Mn  Mo  Sn  Ni  Pb  P  S  V  Zn  SOP AL-16A (CSN EN ISO 22036)","search_en":"Solid matrices Determination of selected elements by ICP-OES method Silver (Ag)  Arsenic (As)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Manganese (Mn)  Molybdenum (Mo)  Tin (Sn)  Nickel (Ni)  Lead (Pb)  Phosphorus (P)  Sulphur (S)  Vanadium (V)  Zinc (Zn)  SOP AL-16A (ČSN EN ISO 22036)","search_zh":"固体基质 所选元素测定（ICP-OES法） 银（Ag）  砷（As）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  锰（Mn）  钼（Mo）  锡（Sn）  镍（Ni）  铅（Pb）  磷（P）  硫（S）  钒（V）  锌（Zn）  SOP AL-16A (ČSN EN ISO 22036)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"89b1608f50663a7ac4f5c0dc","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"20","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok","methodology":"Oznaczanie rtęci ogólnej metodą absorpcyjnej spektrometrii atomowej","methodology_en":"Determination of total mercury by atomic absorption spectrometry","methodology_zh":"总汞测定（原子吸收光谱法）","methodology_cs":"Stanovení celkové rtuti atomovou absorpční spektrometrií","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci ogólnej metodą absorpcyjnej spektrometrii atomowej","reference":"SOP AL-17 (ČSN 75 7440)","norm_bases":["SOP AL-17","ČSN 75 7440"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane | Roztwór absorpcyjny – roztwór absorpcyjny z poboru emisji","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water | Absorption solution – absorption solution from emission sampling","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水 | 吸收液–排放采样吸收液","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní | Absorpční roztok – absorpční roztok z odběru emisí","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny Oznaczanie rtęci ogólnej metodą absorpcyjnej spektrometrii atomowej Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok Stanovení celkové rtuti atomovou absorpční spektrometrií SOP AL-17 (ČSN 75 7440) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny, roztwor absorpcyjny Oznaczanie rteci ogolnej metoda absorpcyjnej spektrometrii atomowej Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok, absorpcni roztok Stanoveni celkove rtuti atomovou absorpcni spektrometrii SOP AL-17 (CSN 75 7440)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution Determination of total mercury by atomic absorption spectrometry SOP AL-17 (ČSN 75 7440)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液 总汞测定（原子吸收光谱法） SOP AL-17 (ČSN 75 7440)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7246c5fd3a05a427254d8aca","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"21","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie rtęci ogólnej metodą absorpcyjnej spektrometrii atomowej","methodology_en":"Determination of total mercury by atomic absorption spectrometry","methodology_zh":"总汞测定（原子吸收光谱法）","methodology_cs":"Stanovení celkové rtuti atomovou absorpční spektrometrií","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci ogólnej metodą absorpcyjnej spektrometrii atomowej","reference":"SOP AL-17A (ČSN 75 7440)","norm_bases":["SOP AL-17A","ČSN 75 7440"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Matryce stałe – różne rodzaje próbek stałych gruntów, osadów dennych, kompostów, osadów, odpadów, gleby, konstrukcji budowlanych","note_en":"Solid matrices – various types of solid samples of soils, sediments, composts, sludge, waste, soil, building structures","note_zh":"固体基质–土、沉积物、堆肥、污泥、废物、土壤、建筑结构等各类固体样品","note_cs":"Pevné matrice – různé typy pevných vzorků zemin, sedimentů, kompostů, kalů, odpadů, půdy, stavebních konstrukcí","search_text":"Matryce stałe Oznaczanie rtęci ogólnej metodą absorpcyjnej spektrometrii atomowej Pevné matrice Stanovení celkové rtuti atomovou absorpční spektrometrií SOP AL-17A (ČSN 75 7440) Matryce stale Oznaczanie rteci ogolnej metoda absorpcyjnej spektrometrii atomowej Pevne matrice Stanoveni celkove rtuti atomovou absorpcni spektrometrii SOP AL-17A (CSN 75 7440)","search_en":"Solid matrices Determination of total mercury by atomic absorption spectrometry SOP AL-17A (ČSN 75 7440)","search_zh":"固体基质 总汞测定（原子吸收光谱法） SOP AL-17A (ČSN 75 7440)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6e6770761a1af5076f3e8052","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"22","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok","methodology":"Oznaczanie chromu sześciowartościowego (Cr6+) – metoda spektrofotometryczna z 1,5-difenylokarbazydem","methodology_en":"Determination of hexavalent chromium (Cr 6+) – spectrophotometric method with 1,5-diphenylcarbazide","methodology_zh":"六价铬（Cr6+）测定–1,5-二苯碳酰二肼分光光度法","methodology_cs":"Stanovení šestimocného chromu (Cr6+) – spektrofotometrická metoda s 1,5-difenylkarbazidem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chromu sześciowartościowego (Cr6+) – metoda spektrofotometryczna z 1,5-difenylokarbazydem","reference":"SOP AL-18 (ČSN ISO 11083)","norm_bases":["SOP AL-18","ČSN ISO 11083"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny Oznaczanie chromu sześciowartościowego (Cr6+) – metoda spektrofotometryczna z 1,5-difenylokarbazydem Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok Stanovení šestimocného chromu (Cr6+) – spektrofotometrická metoda s 1,5-difenylkarbazidem SOP AL-18 (ČSN ISO 11083) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny Oznaczanie chromu szesciowartosciowego (Cr6+) – metoda spektrofotometryczna z 1,5-difenylokarbazydem Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok Stanoveni sestimocneho chromu (Cr6+) – spektrofotometricka metoda s 1,5-difenylkarbazidem SOP AL-18 (CSN ISO 11083)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution Determination of hexavalent chromium (Cr 6+) – spectrophotometric method with 1,5-diphenylcarbazide SOP AL-18 (ČSN ISO 11083)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液 六价铬（Cr6+）测定–1,5-二苯碳酰二肼分光光度法 SOP AL-18 (ČSN ISO 11083)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"67da81d7786ec604b48afd38","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"23","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie żelaza dwuwartościowego (Fe2+) – metoda fotometryczna z 1,10-fenantroliną","methodology_en":"Determination of bivalent iron (Fe2+) – photometric method using 1,10-phenanthroline","methodology_zh":"二价铁（Fe2+）测定–1,10-菲啰啉光度法","methodology_cs":"Stanovení dvojmocného železa (Fe2+) – fotometrická metoda s 1,10-fenantrolinem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie żelaza dwuwartościowego (Fe2+) – metoda fotometryczna z 1,10-fenantroliną","reference":"SOP AL-19 (ČSN ISO 6332)","norm_bases":["SOP AL-19","ČSN ISO 6332"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie żelaza dwuwartościowego (Fe2+) – metoda fotometryczna z 1,10-fenantroliną Pitná, podzemní, povrchová a odpadní voda Stanovení dvojmocného železa (Fe2+) – fotometrická metoda s 1,10-fenantrolinem SOP AL-19 (ČSN ISO 6332) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie zelaza dwuwartosciowego (Fe2+) – metoda fotometryczna z 1,10-fenantrolina Pitna, podzemni, povrchova a odpadni voda Stanoveni dvojmocneho zeleza (Fe2+) – fotometricka metoda s 1,10-fenantrolinem SOP AL-19 (CSN ISO 6332)","search_en":"Drinking, ground, surface and waste water Determination of bivalent iron (Fe2+) – photometric method using 1,10-phenanthroline SOP AL-19 (ČSN ISO 6332)","search_zh":"饮用水、地下水、地表水和废水 二价铁（Fe2+）测定–1,10-菲啰啉光度法 SOP AL-19 (ČSN ISO 6332)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5b6ac77754862d7c955d3645","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"24","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną","methodology_en":"Determination of adsorbable organically bound halogens (AOX) by coulometry","methodology_zh":"可吸附有机卤素（AOX）测定（库仑法）","methodology_cs":"Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną","reference":"SOP AL-20 (ČSN EN ISO 9562)","norm_bases":["SOP AL-20","ČSN EN ISO 9562"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną Pitná, podzemní, povrchová a odpadní voda Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky SOP AL-20 (ČSN EN ISO 9562) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie adsorbowalnych halogenow organicznie zwiazanych (AOX) metoda kulometryczna Pitna, podzemni, povrchova a odpadni voda Stanoveni adsorbovatelnych organicky vazanych halogenu (AOX) coulometricky SOP AL-20 (CSN EN ISO 9562)","search_en":"Drinking, ground, surface and waste water Determination of adsorbable organically bound halogens (AOX) by coulometry SOP AL-20 (ČSN EN ISO 9562)","search_zh":"饮用水、地下水、地表水和废水 可吸附有机卤素（AOX）测定（库仑法） SOP AL-20 (ČSN EN ISO 9562)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"836aec2b2c8538fe075e6f41","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"25","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną","methodology_en":"Determination of adsorbable organically bound halogens (AOX) by coulometry","methodology_zh":"可吸附有机卤素（AOX）测定（库仑法）","methodology_cs":"Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną","reference":"SOP AL-20A (ČSN EN 16166)","norm_bases":["SOP AL-20A","ČSN EN 16166"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Matryce stałe – różne rodzaje próbek stałych gruntów, osadów dennych, kompostów, osadów, odpadów, gleby, konstrukcji budowlanych","note_en":"Solid matrices – various types of solid samples of soils, sediments, composts, sludge, waste, soil, building structures","note_zh":"固体基质–土、沉积物、堆肥、污泥、废物、土壤、建筑结构等各类固体样品","note_cs":"Pevné matrice – různé typy pevných vzorků zemin, sedimentů, kompostů, kalů, odpadů, půdy, stavebních konstrukcí","search_text":"Matryce stałe Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną Pevné matrice Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky SOP AL-20A (ČSN EN 16166) Matryce stale Oznaczanie adsorbowalnych halogenow organicznie zwiazanych (AOX) metoda kulometryczna Pevne matrice Stanoveni adsorbovatelnych organicky vazanych halogenu (AOX) coulometricky SOP AL-20A (CSN EN 16166)","search_en":"Solid matrices Determination of adsorbable organically bound halogens (AOX) by coulometry SOP AL-20A (ČSN EN 16166)","search_zh":"固体基质 可吸附有机卤素（AOX）测定（库仑法） SOP AL-20A (ČSN EN 16166)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0ea68d221b31ebdac1755198","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"26","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie ekstrahowalnych halogenów organicznie związanych (EOX) metodą kulometryczną","methodology_en":"Determination of extractable organically bound halogens (EOX) by coulometry","methodology_zh":"可萃取有机卤素（EOX）测定（库仑法）","methodology_cs":"Stanovení extrahovatelných organicky vázaných halogenů (EOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ekstrahowalnych halogenów organicznie związanych (EOX) metodą kulometryczną","reference":"SOP AL-21 (DIN 38414-S17)","norm_bases":["SOP AL-21","DIN 38414-S17"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Matryce stałe – różne rodzaje próbek stałych gruntów, osadów dennych, kompostów, osadów, odpadów, gleby, konstrukcji budowlanych","note_en":"Solid matrices – various types of solid samples of soils, sediments, composts, sludge, waste, soil, building structures","note_zh":"固体基质–土、沉积物、堆肥、污泥、废物、土壤、建筑结构等各类固体样品","note_cs":"Pevné matrice – různé typy pevných vzorků zemin, sedimentů, kompostů, kalů, odpadů, půdy, stavebních konstrukcí","search_text":"Matryce stałe Oznaczanie ekstrahowalnych halogenów organicznie związanych (EOX) metodą kulometryczną Pevné matrice Stanovení extrahovatelných organicky vázaných halogenů (EOX) coulometricky SOP AL-21 (DIN 38414-S17) Matryce stale Oznaczanie ekstrahowalnych halogenow organicznie zwiazanych (EOX) metoda kulometryczna Pevne matrice Stanoveni extrahovatelnych organicky vazanych halogenu (EOX) coulometricky SOP AL-21 (DIN 38414-S17)","search_en":"Solid matrices Determination of extractable organically bound halogens (EOX) by coulometry SOP AL-21 (DIN 38414-S17)","search_zh":"固体基质 可萃取有机卤素（EOX）测定（库仑法） SOP AL-21 (DIN 38414-S17)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5f3ab9a4a9a3dbb35b215fab","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"27","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok","methodology":"Oznaczanie fenoli jednowodorotlenowych z 4-aminoantypiryną po destylacji metodą spektrofotometryczną","methodology_en":"Determination of phenol index with 4-aminoantipyrine by spectrophotometry after distillation","methodology_zh":"蒸馏后4-氨基安替比林分光光度法测定一元酚","methodology_cs":"Stanovení jednosytných fenolů s 4-aminoantipyrinem po destilaci spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fenoli jednowodorotlenowych z 4-aminoantypiryną po destylacji metodą spektrofotometryczną","reference":"SOP AL-22 (ČSN ISO 6439)","norm_bases":["SOP AL-22","ČSN ISO 6439"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny Oznaczanie fenoli jednowodorotlenowych z 4-aminoantypiryną po destylacji metodą spektrofotometryczną Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok Stanovení jednosytných fenolů s 4-aminoantipyrinem po destilaci spektrofotometricky SOP AL-22 (ČSN ISO 6439) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny Oznaczanie fenoli jednowodorotlenowych z 4-aminoantypiryna po destylacji metoda spektrofotometryczna Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok Stanoveni jednosytnych fenolu s 4-aminoantipyrinem po destilaci spektrofotometricky SOP AL-22 (CSN ISO 6439)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution Determination of phenol index with 4-aminoantipyrine by spectrophotometry after distillation SOP AL-22 (ČSN ISO 6439)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液 蒸馏后4-氨基安替比林分光光度法测定一元酚 SOP AL-22 (ČSN ISO 6439)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"309b6255368f3d338e692f04","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"28","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie anionowych substancji powierzchniowo czynnych (MBAS) metodą fotometryczną","methodology_en":"Determination of anionic surfactants (MBAS) by photometry","methodology_zh":"阴离子表面活性剂（MBAS）测定（光度法）","methodology_cs":"Stanovení aniontových tenzidů (MBAS) fotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie anionowych substancji powierzchniowo czynnych (MBAS) metodą fotometryczną","reference":"SOP AL-23 (ČSN EN 903)","norm_bases":["SOP AL-23","ČSN EN 903"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie anionowych substancji powierzchniowo czynnych (MBAS) metodą fotometryczną Pitná, podzemní, povrchová a odpadní voda Stanovení aniontových tenzidů (MBAS) fotometricky SOP AL-23 (ČSN EN 903) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie anionowych substancji powierzchniowo czynnych (MBAS) metoda fotometryczna Pitna, podzemni, povrchova a odpadni voda Stanoveni aniontovych tenzidu (MBAS) fotometricky SOP AL-23 (CSN EN 903)","search_en":"Drinking, ground, surface and waste water Determination of anionic surfactants (MBAS) by photometry SOP AL-23 (ČSN EN 903)","search_zh":"饮用水、地下水、地表水和废水 阴离子表面活性剂（MBAS）测定（光度法） SOP AL-23 (ČSN EN 903)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a3714dda1b57c37a88b21a3c","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"29","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie anionowych substancji powierzchniowo czynnych (MBAS) metodą fotometryczną – komercyjny zestaw analityczny HACH LANGE","methodology_en":"Determination of anionic surfactants (MBAS) by photometry - HACH LANGE commercial analytical set","methodology_zh":"阴离子表面活性剂（MBAS）测定（光度法）–HACH LANGE商品试剂盒","methodology_cs":"Stanovení aniontových tenzidů (MBAS) fotometricky – analytická komerční souprava HACH LANGE","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie anionowych substancji powierzchniowo czynnych (MBAS) metodą fotometryczną – komercyjny zestaw analityczny HACH LANGE","reference":"SOP AL-24 (návod firmy HACH LANGE)","norm_bases":["SOP AL-24","návod firmy HACH LANGE"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie anionowych substancji powierzchniowo czynnych (MBAS) metodą fotometryczną – komercyjny zestaw analityczny HACH LANGE Pitná, podzemní, povrchová a odpadní voda Stanovení aniontových tenzidů (MBAS) fotometricky – analytická komerční souprava HACH LANGE SOP AL-24 (návod firmy HACH LANGE) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie anionowych substancji powierzchniowo czynnych (MBAS) metoda fotometryczna – komercyjny zestaw analityczny HACH LANGE Pitna, podzemni, povrchova a odpadni voda Stanoveni aniontovych tenzidu (MBAS) fotometricky – analyticka komercni souprava HACH LANGE SOP AL-24 (navod firmy HACH LANGE)","search_en":"Drinking, ground, surface and waste water Determination of anionic surfactants (MBAS) by photometry - HACH LANGE commercial analytical set SOP AL-24 (návod firmy HACH LANGE)","search_zh":"饮用水、地下水、地表水和废水 阴离子表面活性剂（MBAS）测定（光度法）–HACH LANGE商品试剂盒 SOP AL-24 (návod firmy HACH LANGE)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e4b928bd18a28faea45e85cb","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"30","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie tlenu rozpuszczonego – metoda optyczna","methodology_en":"Determination of dissolved oxygen – optical method","methodology_zh":"溶解氧测定–光学法","methodology_cs":"Stanovení rozpuštěného kyslíku – optická metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tlenu rozpuszczonego – metoda optyczna","reference":"SOP AL-25 (ČSN ISO 17289)","norm_bases":["SOP AL-25","ČSN ISO 17289"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie tlenu rozpuszczonego – metoda optyczna Pitná, podzemní, povrchová a odpadní voda Stanovení rozpuštěného kyslíku – optická metoda SOP AL-25 (ČSN ISO 17289) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie tlenu rozpuszczonego – metoda optyczna Pitna, podzemni, povrchova a odpadni voda Stanoveni rozpusteneho kysliku – opticka metoda SOP AL-25 (CSN ISO 17289)","search_en":"Drinking, ground, surface and waste water Determination of dissolved oxygen – optical method SOP AL-25 (ČSN ISO 17289)","search_zh":"饮用水、地下水、地表水和废水 溶解氧测定–光学法 SOP AL-25 (ČSN ISO 17289)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ed729f697cc69b22690d1002","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"31","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice","methodology":"Oznaczanie substancji rozpuszczonych i rozpuszczonych soli nieorganicznych (RAS) metodą wagową","methodology_en":"Determination of dissolved solids and dissolved inorganic salts (DIS) by gravimetry","methodology_zh":"溶解性固体和溶解性无机盐测定（重量法）","methodology_cs":"Stanovení rozpuštěných látek a rozpuštěných anorganických solí (RAS) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych i rozpuszczonych soli nieorganicznych (RAS) metodą wagową","reference":"SOP AL-26 (ČSN 75 7346; ČSN 75 7347)","norm_bases":["SOP AL-26","ČSN 75 7346","ČSN 75 7347"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej Oznaczanie substancji rozpuszczonych i rozpuszczonych soli nieorganicznych (RAS) metodą wagową Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice Stanovení rozpuštěných látek a rozpuštěných anorganických solí (RAS) gravimetricky SOP AL-26 (ČSN 75 7346; ČSN 75 7347) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej Oznaczanie substancji rozpuszczonych i rozpuszczonych soli nieorganicznych (RAS) metoda wagowa Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice Stanoveni rozpustenych latek a rozpustenych anorganickych soli (RAS) gravimetricky SOP AL-26 (CSN 75 7346; CSN 75 7347)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix Determination of dissolved solids and dissolved inorganic salts (DIS) by gravimetry SOP AL-26 (ČSN 75 7346; ČSN 75 7347)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液 溶解性固体和溶解性无机盐测定（重量法） SOP AL-26 (ČSN 75 7346; ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"23d738fee53e340ca9cab375","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"32","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie zawiesiny ogólnej metodą wagową","methodology_en":"Determination of suspended solids by gravimetry","methodology_zh":"悬浮物测定（重量法）","methodology_cs":"Stanovení nerozpuštěných látek gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesiny ogólnej metodą wagową","reference":"SOP AL-27 (ČSN EN 872)","norm_bases":["SOP AL-27","ČSN EN 872"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie zawiesiny ogólnej metodą wagową Pitná, podzemní, povrchová a odpadní voda Stanovení nerozpuštěných látek gravimetricky SOP AL-27 (ČSN EN 872) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie zawiesiny ogolnej metoda wagowa Pitna, podzemni, povrchova a odpadni voda Stanoveni nerozpustenych latek gravimetricky SOP AL-27 (CSN EN 872)","search_en":"Drinking, ground, surface and waste water Determination of suspended solids by gravimetry SOP AL-27 (ČSN EN 872)","search_zh":"饮用水、地下水、地表水和废水 悬浮物测定（重量法） SOP AL-27 (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"289f27c457e64f1e63d1044a","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"33","test_object":"Wody powierzchniowe, podziemne i ścieki","test_object_en":"Surface, ground and waste water","test_object_zh":"地表水、地下水和废水","test_object_cs":"Povrchová, podzemní a odpadní voda","methodology":"Oznaczanie biochemicznego zapotrzebowania na tlen BZT5 – metoda optyczna","methodology_en":"Determination of biochemical oxygen demand (BOD5) - optical method","methodology_zh":"五日生化需氧量（BOD5）测定–光学法","methodology_cs":"Stanovení biochemické spotřeby kyslíku BSK5 – optická metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania na tlen BZT5 – metoda optyczna","reference":"SOP AL-28 (ČSN EN ISO 5815-1; ČSN ISO 17289)","norm_bases":["SOP AL-28","ČSN EN ISO 5815-1","ČSN ISO 17289"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Wody powierzchniowe, podziemne i ścieki Oznaczanie biochemicznego zapotrzebowania na tlen BZT5 – metoda optyczna Povrchová, podzemní a odpadní voda Stanovení biochemické spotřeby kyslíku BSK5 – optická metoda SOP AL-28 (ČSN EN ISO 5815-1; ČSN ISO 17289) Wody powierzchniowe, podziemne i scieki Oznaczanie biochemicznego zapotrzebowania na tlen BZT5 – metoda optyczna Povrchova, podzemni a odpadni voda Stanoveni biochemicke spotreby kysliku BSK5 – opticka metoda SOP AL-28 (CSN EN ISO 5815-1; CSN ISO 17289)","search_en":"Surface, ground and waste water Determination of biochemical oxygen demand (BOD5) - optical method SOP AL-28 (ČSN EN ISO 5815-1; ČSN ISO 17289)","search_zh":"地表水、地下水和废水 五日生化需氧量（BOD5）测定–光学法 SOP AL-28 (ČSN EN ISO 5815-1; ČSN ISO 17289)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"88c2da35b4385f0c12cfdccf","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"34","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice","methodology":"Oznaczanie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO) metodą fotometryczną – komercyjny zestaw analityczny HACH LANGE","methodology_en":"Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) photometrically - HACH LANGE commercial analytical kit","methodology_zh":"总有机碳（TOC）和溶解性有机碳（DOC）测定（光度法）–HACH LANGE商品试剂盒","methodology_cs":"Stanovení celkového organického uhlíku (TOC) a rozpuštěného organického uhlíku (DOC) fotometricky – analytická komerční souprava HACH LANGE","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO) metodą fotometryczną – komercyjny zestaw analityczny HACH LANGE","reference":"SOP AL-29 (návod firmy HACH LANGE)","norm_bases":["SOP AL-29","návod firmy HACH LANGE"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej Oznaczanie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO) metodą fotometryczną – komercyjny zestaw analityczny HACH LANGE Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice Stanovení celkového organického uhlíku (TOC) a rozpuštěného organického uhlíku (DOC) fotometricky – analytická komerční souprava HACH LANGE SOP AL-29 (návod firmy HACH LANGE) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej Oznaczanie ogolnego wegla organicznego (OWO) i rozpuszczonego wegla organicznego (RWO) metoda fotometryczna – komercyjny zestaw analityczny HACH LANGE Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice Stanoveni celkoveho organickeho uhliku (TOC) a rozpusteneho organickeho uhliku (DOC) fotometricky – analyticka komercni souprava HACH LANGE SOP AL-29 (navod firmy HACH LANGE)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) photometrically - HACH LANGE commercial analytical kit SOP AL-29 (návod firmy HACH LANGE)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液 总有机碳（TOC）和溶解性有机碳（DOC）测定（光度法）–HACH LANGE商品试剂盒 SOP AL-29 (návod firmy HACH LANGE)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b5fa1305ff43a78dabdd6df0","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"35","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dwuchromianową (ChZT-Cr) metodą spektrofotometryczną – komercyjny zestaw analityczny HACH LANGE","methodology_en":"Determination of chemical oxygen demand with dichromate (COD-Cr) by spectrophotometry - HACH LANGE commercial analytical set","methodology_zh":"重铬酸盐化学需氧量（COD-Cr）测定（分光光度法）–HACH LANGE商品试剂盒","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem (CHSK-Cr) spektrofotometricky – analytická komerční souprava HACH LANGE","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dwuchromianową (ChZT-Cr) metodą spektrofotometryczną – komercyjny zestaw analityczny HACH LANGE","reference":"SOP AL-30 (návod firmy HACH LANGE)","norm_bases":["SOP AL-30","návod firmy HACH LANGE"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie chemicznego zapotrzebowania na tlen metodą dwuchromianową (ChZT-Cr) metodą spektrofotometryczną – komercyjny zestaw analityczny HACH LANGE Pitná, podzemní, povrchová a odpadní voda Stanovení chemické spotřeby kyslíku dichromanem (CHSK-Cr) spektrofotometricky – analytická komerční souprava HACH LANGE SOP AL-30 (návod firmy HACH LANGE) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie chemicznego zapotrzebowania na tlen metoda dwuchromianowa (ChZT-Cr) metoda spektrofotometryczna – komercyjny zestaw analityczny HACH LANGE Pitna, podzemni, povrchova a odpadni voda Stanoveni chemicke spotreby kysliku dichromanem (CHSK-Cr) spektrofotometricky – analyticka komercni souprava HACH LANGE SOP AL-30 (navod firmy HACH LANGE)","search_en":"Drinking, ground, surface and waste water Determination of chemical oxygen demand with dichromate (COD-Cr) by spectrophotometry - HACH LANGE commercial analytical set SOP AL-30 (návod firmy HACH LANGE)","search_zh":"饮用水、地下水、地表水和废水 重铬酸盐化学需氧量（COD-Cr）测定（分光光度法）–HACH LANGE商品试剂盒 SOP AL-30 (návod firmy HACH LANGE)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"86a23e54957c46b7304b914e","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"36","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice","methodology":"Oznaczanie azotu ogólnego (TN) metodą fotometryczną – komercyjny zestaw analityczny HACH LANGE","methodology_en":"Determination of total nitrogen (TN) photometrically - HACH LANGE commercial analytical set","methodology_zh":"总氮（TN）测定（光度法）–HACH LANGE商品试剂盒","methodology_cs":"Stanovení celkového dusíku (TN) fotometricky – analytická komerční souprava HACH LANGE","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu ogólnego (TN) metodą fotometryczną – komercyjny zestaw analityczny HACH LANGE","reference":"SOP AL-31 (návod firmy HACH LANGE)","norm_bases":["SOP AL-31","návod firmy HACH LANGE"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej Oznaczanie azotu ogólnego (TN) metodą fotometryczną – komercyjny zestaw analityczny HACH LANGE Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice Stanovení celkového dusíku (TN) fotometricky – analytická komerční souprava HACH LANGE SOP AL-31 (návod firmy HACH LANGE) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej Oznaczanie azotu ogolnego (TN) metoda fotometryczna – komercyjny zestaw analityczny HACH LANGE Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice Stanoveni celkoveho dusiku (TN) fotometricky – analyticka komercni souprava HACH LANGE SOP AL-31 (navod firmy HACH LANGE)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix Determination of total nitrogen (TN) photometrically - HACH LANGE commercial analytical set SOP AL-31 (návod firmy HACH LANGE)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液 总氮（TN）测定（光度法）–HACH LANGE商品试剂盒 SOP AL-31 (návod firmy HACH LANGE)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e1217bf18aa027d2e799b2ef","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"37","test_object":"Matryce stałe, bioodpady, materiał roślinny","test_object_en":"Solid matrices, biowaste, plant material","test_object_zh":"固体基质、生物废物、植物材料","test_object_cs":"Pevné matrice, bioodpad, rostlinný materiál","methodology":"Oznaczanie węgla (OWO, TIC, TC), azotu ogólnego (TN) i siarki ogólnej (TS) analizatorem spaleniowym z detekcją TCD","methodology_en":"Determination of carbon (TOC, TIC, TC), total nitrogen (TN) and total sulphur (TS) by combustion analyzer with TCD detection","methodology_zh":"燃烧分析仪TCD检测法测定碳（TOC、TIC、TC）、总氮（TN）和总硫（TS）","methodology_cs":"Stanovení uhlíku (TOC, TIC, TC), celkového dusíku (TN) a celkové síry (TS) spalovacím analyzátorem s TCD detekcí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węgla (OWO, TIC, TC), azotu ogólnego (TN) i siarki ogólnej (TS) analizatorem spaleniowym z detekcją TCD","reference":"SOP AL-32 (ČSN EN 15936; manuál k přístroji Flash 2000 od firmy Thermo Scientific, str. 119)","norm_bases":["SOP AL-32","ČSN EN 15936","manuál k přístroji Flash 2000 od firmy Thermo Scientific, str. 119"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Matryce stałe – różne rodzaje próbek stałych gruntów, osadów dennych, kompostów, osadów, odpadów, gleby, konstrukcji budowlanych | Bioodpady – odpady ulegające biodegradacji i komunalne odpady ulegające biodegradacji, zdolne do rozkładu beztlenowego lub tlenowego. Materiał roślinny – korzenie, łodygi, kwiaty i liście roślin","note_en":"Solid matrices – various types of solid samples of soils, sediments, composts, sludge, waste, soil, building structures | Biowaste – biodegradable waste and biodegradable municipal waste capable of anaerobic or aerobic decomposition. Plant material – roots, stems, flowers and leaves of plants","note_zh":"固体基质–土、沉积物、堆肥、污泥、废物、土壤、建筑结构等各类固体样品 | 生物废物–可厌氧或好氧分解的可生物降解废物和城市废物。植物材料–植物的根、茎、花和叶","note_cs":"Pevné matrice – různé typy pevných vzorků zemin, sedimentů, kompostů, kalů, odpadů, půdy, stavebních konstrukcí | Bioodpad – biologicky rozložitelný odpad a biologicky rozložitelný komunální odpad, který je schopen anaerobního nebo aerobního rozkladu. Rostlinný materiál – kořeny, stonky, květy a listy rostlin","search_text":"Matryce stałe, bioodpady, materiał roślinny Oznaczanie węgla (OWO, TIC, TC), azotu ogólnego (TN) i siarki ogólnej (TS) analizatorem spaleniowym z detekcją TCD Pevné matrice, bioodpad, rostlinný materiál Stanovení uhlíku (TOC, TIC, TC), celkového dusíku (TN) a celkové síry (TS) spalovacím analyzátorem s TCD detekcí SOP AL-32 (ČSN EN 15936; manuál k přístroji Flash 2000 od firmy Thermo Scientific, str. 119) Matryce stale, bioodpady, material roslinny Oznaczanie wegla (OWO, TIC, TC), azotu ogolnego (TN) i siarki ogolnej (TS) analizatorem spaleniowym z detekcja TCD Pevne matrice, bioodpad, rostlinny material Stanoveni uhliku (TOC, TIC, TC), celkoveho dusiku (TN) a celkove siry (TS) spalovacim analyzatorem s TCD detekci SOP AL-32 (CSN EN 15936; manual k pristroji Flash 2000 od firmy Thermo Scientific, str. 119)","search_en":"Solid matrices, biowaste, plant material Determination of carbon (TOC, TIC, TC), total nitrogen (TN) and total sulphur (TS) by combustion analyzer with TCD detection SOP AL-32 (ČSN EN 15936; manuál k přístroji Flash 2000 od firmy Thermo Scientific, str. 119)","search_zh":"固体基质、生物废物、植物材料 燃烧分析仪TCD检测法测定碳（TOC、TIC、TC）、总氮（TN）和总硫（TS） SOP AL-32 (ČSN EN 15936; manuál k přístroji Flash 2000 od firmy Thermo Scientific, str. 119)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1709d0a323d6da1e0a6da9bc","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"38","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie eteru metylo-tert-butylowego (MTBE) i eteru etylo-tert-butylowego (ETBE) metodą GC/MS headspace","methodology_en":"Determination of methyl tert-butyl ether (MTBE) and ethyl tert-butyl ether (ETBE) by GC/MS headspace method","methodology_zh":"顶空GC/MS法测定甲基叔丁基醚（MTBE）和乙基叔丁基醚（ETBE）","methodology_cs":"Stanovení methyl terc-butyl etheru (MTBE) a ethyl terc-butyl etheru (ETBE) metodou GC/MS headspace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie eteru metylo-tert-butylowego (MTBE) i eteru etylo-tert-butylowego (ETBE) metodą GC/MS headspace","reference":"SOP AL-33 (ČSN EN ISO 17943; EPA Method 8260C)","norm_bases":["SOP AL-33","ČSN EN ISO 17943","EPA Method 8260C"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie eteru metylo-tert-butylowego (MTBE) i eteru etylo-tert-butylowego (ETBE) metodą GC/MS headspace Pitná, podzemní, povrchová a odpadní voda Stanovení methyl terc-butyl etheru (MTBE) a ethyl terc-butyl etheru (ETBE) metodou GC/MS headspace SOP AL-33 (ČSN EN ISO 17943; EPA Method 8260C) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie eteru metylo-tert-butylowego (MTBE) i eteru etylo-tert-butylowego (ETBE) metoda GC/MS headspace Pitna, podzemni, povrchova a odpadni voda Stanoveni methyl terc-butyl etheru (MTBE) a ethyl terc-butyl etheru (ETBE) metodou GC/MS headspace SOP AL-33 (CSN EN ISO 17943; EPA Method 8260C)","search_en":"Drinking, ground, surface and waste water Determination of methyl tert-butyl ether (MTBE) and ethyl tert-butyl ether (ETBE) by GC/MS headspace method SOP AL-33 (ČSN EN ISO 17943; EPA Method 8260C)","search_zh":"饮用水、地下水、地表水和废水 顶空GC/MS法测定甲基叔丁基醚（MTBE）和乙基叔丁基醚（ETBE） SOP AL-33 (ČSN EN ISO 17943; EPA Method 8260C)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3a237ea62b82c6bcbd12800d","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"39","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie LZO metodą GC/MS headspace i obliczanie sumy LZO z wartości zmierzonych","methodology_en":"Determination of VOC by GC/MS headspace method and calculation of the sum of VOC from the measured values","methodology_zh":"顶空GC/MS法测定挥发性有机物及由测量值计算其总和","methodology_cs":"Stanovení TOL metodou GC/MS headspace a výpočet sumy TOL z naměřených hodnot","parameters":[{"name":"1,1-dichloroeten","range":""},{"name":"cis-1,2-dichloroeten","range":""},{"name":"trans-1,2-dichloroeten","range":""},{"name":"trichloroeten","range":""},{"name":"tetrachloroeten","range":""},{"name":"1,2-dichloroetan","range":""},{"name":"dichlorometan","range":""},{"name":"trichlorometan","range":""},{"name":"tetrachlorometan","range":""},{"name":"bromodichlorometan","range":""},{"name":"dibromochlorometan","range":""},{"name":"tribromometan","range":""},{"name":"chlorobenzen","range":""},{"name":"dichlorobenzeny","range":""},{"name":"chlorek winylu","range":""},{"name":"benzen","range":""},{"name":"toluen","range":""},{"name":"etylobenzen","range":""},{"name":"ksyleny","range":""},{"name":"1,1-dichloroetan","range":""},{"name":"1,1,2-trichloroetan","range":""},{"name":"1,1,1,2-tetrachloroetan","range":""},{"name":"1,1,2,2-tetrachloroetan","range":""}],"parameters_en":[{"name":"1,1-dichloroethene","range":""},{"name":"cis-1,2-dichloroethene","range":""},{"name":"trans-1,2-dichloroethene","range":""},{"name":"trichloroethene","range":""},{"name":"tetrachloroethene","range":""},{"name":"1,2-dichloroethane","range":""},{"name":"dichloromethane","range":""},{"name":"trichloromethane","range":""},{"name":"tetrachloromethane","range":""},{"name":"bromodichloromethane","range":""},{"name":"dibromochloromethane","range":""},{"name":"tribromomethane","range":""},{"name":"chlorobenzene","range":""},{"name":"dichlorobenzenes","range":""},{"name":"vinyl chloride","range":""},{"name":"benzene","range":""},{"name":"toluene","range":""},{"name":"ethylbenzene","range":""},{"name":"xylenes","range":""},{"name":"1,1-dichloroethane","range":""},{"name":"1,1,2-trichloroethane","range":""},{"name":"1,1,1,2-tetrachloroethane","range":""},{"name":"1,1,2,2-tetrachloroethane","range":""}],"parameters_zh":[{"name":"1,1-二氯乙烯","range":""},{"name":"顺式-1,2-二氯乙烯","range":""},{"name":"反式-1,2-二氯乙烯","range":""},{"name":"三氯乙烯","range":""},{"name":"四氯乙烯","range":""},{"name":"1,2-二氯乙烷","range":""},{"name":"二氯甲烷","range":""},{"name":"三氯甲烷","range":""},{"name":"四氯化碳","range":""},{"name":"一溴二氯甲烷","range":""},{"name":"二溴一氯甲烷","range":""},{"name":"三溴甲烷","range":""},{"name":"氯苯","range":""},{"name":"二氯苯","range":""},{"name":"氯乙烯","range":""},{"name":"苯","range":""},{"name":"甲苯","range":""},{"name":"乙苯","range":""},{"name":"二甲苯","range":""},{"name":"1,1-二氯乙烷","range":""},{"name":"1,1,2-三氯乙烷","range":""},{"name":"1,1,1,2-四氯乙烷","range":""},{"name":"1,1,2,2-四氯乙烷","range":""}],"parameters_cs":[{"name":"1,1-dichlorethen","range":""},{"name":"cis-1,2-dichlorethen","range":""},{"name":"trans-1,2-dichlorethen","range":""},{"name":"trichlorethen","range":""},{"name":"tetrachlorethen","range":""},{"name":"1,2-dichlorethan","range":""},{"name":"dichlormethan","range":""},{"name":"trichlormethan","range":""},{"name":"tetrachlormethan","range":""},{"name":"bromdichlormethan","range":""},{"name":"dibromchlormethan","range":""},{"name":"tribrommethan","range":""},{"name":"chlorbenzen","range":""},{"name":"dichlorbenzeny","range":""},{"name":"vinylchlorid","range":""},{"name":"benzen","range":""},{"name":"toluen","range":""},{"name":"ethylbenzen","range":""},{"name":"xyleny","range":""},{"name":"1,1-dichlorethan","range":""},{"name":"1,1,2-trichlorethan","range":""},{"name":"1,1,1,2-tetrachlorethan","range":""},{"name":"1,1,2,2-tetrachlorethan","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma BTEX","obliczeniowo: sumy wybranych THM","sumy wybranych chlorowanych węglowodorów (ClU)"],"computed_en":["sum of BTEX","by calculation: sums of selected THM","sums of selected chlorinated hydrocarbons (ClU)"],"computed_zh":["BTEX总和","计算：所选三卤甲烷总和","所选氯代烃总和"],"computed_cs":["suma BTEX","výpočtem: sumy vybraných THM","sumy vybraných ClU"],"activity":"Oznaczanie LZO metodą GC/MS headspace i obliczanie sumy LZO z wartości zmierzonych\nZakres:\n1,1-dichloroeten\ncis-1,2-dichloroeten\ntrans-1,2-dichloroeten\ntrichloroeten\ntetrachloroeten\n1,2-dichloroetan\ndichlorometan\ntrichlorometan\ntetrachlorometan\nbromodichlorometan\ndibromochlorometan\ntribromometan\nchlorobenzen\ndichlorobenzeny\nchlorek winylu\nbenzen\ntoluen\netylobenzen\nksyleny\n1,1-dichloroetan\n1,1,2-trichloroetan\n1,1,1,2-tetrachloroetan\n1,1,2,2-tetrachloroetan","reference":"SOP AL-34 (ČSN EN ISO 10301)","norm_bases":["SOP AL-34","ČSN EN ISO 10301"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie LZO metodą GC/MS headspace i obliczanie sumy LZO z wartości zmierzonych 1,1-dichloroeten  cis-1,2-dichloroeten  trans-1,2-dichloroeten  trichloroeten  tetrachloroeten  1,2-dichloroetan  dichlorometan  trichlorometan  tetrachlorometan  bromodichlorometan  dibromochlorometan  tribromometan  chlorobenzen  dichlorobenzeny  chlorek winylu  benzen  toluen  etylobenzen  ksyleny  1,1-dichloroetan  1,1,2-trichloroetan  1,1,1,2-tetrachloroetan  1,1,2,2-tetrachloroetan  suma BTEX obliczeniowo: sumy wybranych THM sumy wybranych chlorowanych węglowodorów (ClU) Pitná, podzemní, povrchová a odpadní voda Stanovení TOL metodou GC/MS headspace a výpočet sumy TOL z naměřených hodnot 1,1-dichlorethen  cis-1,2-dichlorethen  trans-1,2-dichlorethen  trichlorethen  tetrachlorethen  1,2-dichlorethan  dichlormethan  trichlormethan  tetrachlormethan  bromdichlormethan  dibromchlormethan  tribrommethan  chlorbenzen  dichlorbenzeny  vinylchlorid  benzen  toluen  ethylbenzen  xyleny  1,1-dichlorethan  1,1,2-trichlorethan  1,1,1,2-tetrachlorethan  1,1,2,2-tetrachlorethan  suma BTEX výpočtem: sumy vybraných THM sumy vybraných ClU SOP AL-34 (ČSN EN ISO 10301) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie LZO metoda GC/MS headspace i obliczanie sumy LZO z wartosci zmierzonych 1,1-dichloroeten  cis-1,2-dichloroeten  trans-1,2-dichloroeten  trichloroeten  tetrachloroeten  1,2-dichloroetan  dichlorometan  trichlorometan  tetrachlorometan  bromodichlorometan  dibromochlorometan  tribromometan  chlorobenzen  dichlorobenzeny  chlorek winylu  benzen  toluen  etylobenzen  ksyleny  1,1-dichloroetan  1,1,2-trichloroetan  1,1,1,2-tetrachloroetan  1,1,2,2-tetrachloroetan  suma BTEX obliczeniowo: sumy wybranych THM sumy wybranych chlorowanych weglowodorow (ClU) Pitna, podzemni, povrchova a odpadni voda Stanoveni TOL metodou GC/MS headspace a vypocet sumy TOL z namerenych hodnot 1,1-dichlorethen  cis-1,2-dichlorethen  trans-1,2-dichlorethen  trichlorethen  tetrachlorethen  1,2-dichlorethan  dichlormethan  trichlormethan  tetrachlormethan  bromdichlormethan  dibromchlormethan  tribrommethan  chlorbenzen  dichlorbenzeny  vinylchlorid  benzen  toluen  ethylbenzen  xyleny  1,1-dichlorethan  1,1,2-trichlorethan  1,1,1,2-tetrachlorethan  1,1,2,2-tetrachlorethan  suma BTEX vypoctem: sumy vybranych THM sumy vybranych ClU SOP AL-34 (CSN EN ISO 10301)","search_en":"Drinking, ground, surface and waste water Determination of VOC by GC/MS headspace method and calculation of the sum of VOC from the measured values 1,1-dichloroethene  cis-1,2-dichloroethene  trans-1,2-dichloroethene  trichloroethene  tetrachloroethene  1,2-dichloroethane  dichloromethane  trichloromethane  tetrachloromethane  bromodichloromethane  dibromochloromethane  tribromomethane  chlorobenzene  dichlorobenzenes  vinyl chloride  benzene  toluene  ethylbenzene  xylenes  1,1-dichloroethane  1,1,2-trichloroethane  1,1,1,2-tetrachloroethane  1,1,2,2-tetrachloroethane  sum of BTEX by calculation: sums of selected THM sums of selected chlorinated hydrocarbons (ClU) SOP AL-34 (ČSN EN ISO 10301)","search_zh":"饮用水、地下水、地表水和废水 顶空GC/MS法测定挥发性有机物及由测量值计算其总和 1,1-二氯乙烯  顺式-1,2-二氯乙烯  反式-1,2-二氯乙烯  三氯乙烯  四氯乙烯  1,2-二氯乙烷  二氯甲烷  三氯甲烷  四氯化碳  一溴二氯甲烷  二溴一氯甲烷  三溴甲烷  氯苯  二氯苯  氯乙烯  苯  甲苯  乙苯  二甲苯  1,1-二氯乙烷  1,1,2-三氯乙烷  1,1,1,2-四氯乙烷  1,1,2,2-四氯乙烷  BTEX总和 计算：所选三卤甲烷总和 所选氯代烃总和 SOP AL-34 (ČSN EN ISO 10301)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"366c54ee5e228defef10bec4","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"40","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie LZO metodą GC/MS headspace i obliczanie sumy LZO z wartości zmierzonych","methodology_en":"Determination of VOC by GC/MS headspace method and calculation of the sum of VOC from the measured values","methodology_zh":"顶空GC/MS法测定挥发性有机物及由测量值计算其总和","methodology_cs":"Stanovení TOL metodou GC/MS headspace a výpočet sumy TOL z naměřených hodnot","parameters":[{"name":"1,1-dichloroeten","range":""},{"name":"cis-1,2-dichloroeten","range":""},{"name":"trans-1,2-dichloroeten","range":""},{"name":"trichloroeten","range":""},{"name":"tetrachloroeten","range":""},{"name":"1,2-dichloroetan","range":""},{"name":"dichlorometan","range":""},{"name":"trichlorometan","range":""},{"name":"tetrachlorometan","range":""},{"name":"bromodichlorometan","range":""},{"name":"dibromochlorometan","range":""},{"name":"tribromometan","range":""},{"name":"chlorobenzen","range":""},{"name":"dichlorobenzeny","range":""},{"name":"benzen","range":""},{"name":"toluen","range":""},{"name":"etylobenzen","range":""},{"name":"ksyleny","range":""}],"parameters_en":[{"name":"1,1-dichloroethene","range":""},{"name":"cis-1,2-dichloroethene","range":""},{"name":"trans-1,2-dichloroethene","range":""},{"name":"trichloroethene","range":""},{"name":"tetrachloroethene","range":""},{"name":"1,2-dichloroethane","range":""},{"name":"dichloromethane","range":""},{"name":"trichloromethane","range":""},{"name":"tetrachloromethane","range":""},{"name":"bromodichloromethane","range":""},{"name":"dibromochloromethane","range":""},{"name":"tribromomethane","range":""},{"name":"chlorobenzene","range":""},{"name":"dichlorobenzenes","range":""},{"name":"benzene","range":""},{"name":"toluene","range":""},{"name":"ethylbenzene","range":""},{"name":"xylenes","range":""}],"parameters_zh":[{"name":"1,1-二氯乙烯","range":""},{"name":"顺式-1,2-二氯乙烯","range":""},{"name":"反式-1,2-二氯乙烯","range":""},{"name":"三氯乙烯","range":""},{"name":"四氯乙烯","range":""},{"name":"1,2-二氯乙烷","range":""},{"name":"二氯甲烷","range":""},{"name":"三氯甲烷","range":""},{"name":"四氯化碳","range":""},{"name":"一溴二氯甲烷","range":""},{"name":"二溴一氯甲烷","range":""},{"name":"三溴甲烷","range":""},{"name":"氯苯","range":""},{"name":"二氯苯","range":""},{"name":"苯","range":""},{"name":"甲苯","range":""},{"name":"乙苯","range":""},{"name":"二甲苯","range":""}],"parameters_cs":[{"name":"1,1-dichlorethen","range":""},{"name":"cis-1,2-dichlorethen","range":""},{"name":"trans-1,2-dichlorethen","range":""},{"name":"trichlorethen","range":""},{"name":"tetrachlorethen","range":""},{"name":"1,2-dichlorethan","range":""},{"name":"dichlormethan","range":""},{"name":"trichlormethan","range":""},{"name":"tetrachlormethan","range":""},{"name":"bromdichlormethan","range":""},{"name":"dibromchlormethan","range":""},{"name":"tribrommethan","range":""},{"name":"chlorbenzen","range":""},{"name":"dichlorbenzeny","range":""},{"name":"benzen","range":""},{"name":"toluen","range":""},{"name":"ethylbenzen","range":""},{"name":"xyleny","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma BTEX","obliczeniowo: sumy wybranych THM","sumy wybranych chlorowanych węglowodorów (ClU)"],"computed_en":["sum of BTEX","by calculation: sums of selected THM","sums of selected chlorinated hydrocarbons (ClU)"],"computed_zh":["BTEX总和","计算：所选三卤甲烷总和","所选氯代烃总和"],"computed_cs":["suma BTEX","výpočtem: sumy vybraných THM","sumy vybraných ClU"],"activity":"Oznaczanie LZO metodą GC/MS headspace i obliczanie sumy LZO z wartości zmierzonych\nZakres:\n1,1-dichloroeten\ncis-1,2-dichloroeten\ntrans-1,2-dichloroeten\ntrichloroeten\ntetrachloroeten\n1,2-dichloroetan\ndichlorometan\ntrichlorometan\ntetrachlorometan\nbromodichlorometan\ndibromochlorometan\ntribromometan\nchlorobenzen\ndichlorobenzeny\nbenzen\ntoluen\netylobenzen\nksyleny","reference":"SOP AL-34A (ČSN EN ISO 22155)","norm_bases":["SOP AL-34A","ČSN EN ISO 22155"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Matryce stałe – różne rodzaje próbek stałych gruntów, osadów dennych, kompostów, osadów, odpadów, gleby, konstrukcji budowlanych","note_en":"Solid matrices – various types of solid samples of soils, sediments, composts, sludge, waste, soil, building structures","note_zh":"固体基质–土、沉积物、堆肥、污泥、废物、土壤、建筑结构等各类固体样品","note_cs":"Pevné matrice – různé typy pevných vzorků zemin, sedimentů, kompostů, kalů, odpadů, půdy, stavebních konstrukcí","search_text":"Matryce stałe Oznaczanie LZO metodą GC/MS headspace i obliczanie sumy LZO z wartości zmierzonych 1,1-dichloroeten  cis-1,2-dichloroeten  trans-1,2-dichloroeten  trichloroeten  tetrachloroeten  1,2-dichloroetan  dichlorometan  trichlorometan  tetrachlorometan  bromodichlorometan  dibromochlorometan  tribromometan  chlorobenzen  dichlorobenzeny  benzen  toluen  etylobenzen  ksyleny  suma BTEX obliczeniowo: sumy wybranych THM sumy wybranych chlorowanych węglowodorów (ClU) Pevné matrice Stanovení TOL metodou GC/MS headspace a výpočet sumy TOL z naměřených hodnot 1,1-dichlorethen  cis-1,2-dichlorethen  trans-1,2-dichlorethen  trichlorethen  tetrachlorethen  1,2-dichlorethan  dichlormethan  trichlormethan  tetrachlormethan  bromdichlormethan  dibromchlormethan  tribrommethan  chlorbenzen  dichlorbenzeny  benzen  toluen  ethylbenzen  xyleny  suma BTEX výpočtem: sumy vybraných THM sumy vybraných ClU SOP AL-34A (ČSN EN ISO 22155) Matryce stale Oznaczanie LZO metoda GC/MS headspace i obliczanie sumy LZO z wartosci zmierzonych 1,1-dichloroeten  cis-1,2-dichloroeten  trans-1,2-dichloroeten  trichloroeten  tetrachloroeten  1,2-dichloroetan  dichlorometan  trichlorometan  tetrachlorometan  bromodichlorometan  dibromochlorometan  tribromometan  chlorobenzen  dichlorobenzeny  benzen  toluen  etylobenzen  ksyleny  suma BTEX obliczeniowo: sumy wybranych THM sumy wybranych chlorowanych weglowodorow (ClU) Pevne matrice Stanoveni TOL metodou GC/MS headspace a vypocet sumy TOL z namerenych hodnot 1,1-dichlorethen  cis-1,2-dichlorethen  trans-1,2-dichlorethen  trichlorethen  tetrachlorethen  1,2-dichlorethan  dichlormethan  trichlormethan  tetrachlormethan  bromdichlormethan  dibromchlormethan  tribrommethan  chlorbenzen  dichlorbenzeny  benzen  toluen  ethylbenzen  xyleny  suma BTEX vypoctem: sumy vybranych THM sumy vybranych ClU SOP AL-34A (CSN EN ISO 22155)","search_en":"Solid matrices Determination of VOC by GC/MS headspace method and calculation of the sum of VOC from the measured values 1,1-dichloroethene  cis-1,2-dichloroethene  trans-1,2-dichloroethene  trichloroethene  tetrachloroethene  1,2-dichloroethane  dichloromethane  trichloromethane  tetrachloromethane  bromodichloromethane  dibromochloromethane  tribromomethane  chlorobenzene  dichlorobenzenes  benzene  toluene  ethylbenzene  xylenes  sum of BTEX by calculation: sums of selected THM sums of selected chlorinated hydrocarbons (ClU) SOP AL-34A (ČSN EN ISO 22155)","search_zh":"固体基质 顶空GC/MS法测定挥发性有机物及由测量值计算其总和 1,1-二氯乙烯  顺式-1,2-二氯乙烯  反式-1,2-二氯乙烯  三氯乙烯  四氯乙烯  1,2-二氯乙烷  二氯甲烷  三氯甲烷  四氯化碳  一溴二氯甲烷  二溴一氯甲烷  三溴甲烷  氯苯  二氯苯  苯  甲苯  乙苯  二甲苯  BTEX总和 计算：所选三卤甲烷总和 所选氯代烃总和 SOP AL-34A (ČSN EN ISO 22155)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cb41a44ae3306cce9c43e51b","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"41","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie LZO metodą GC/FID i obliczanie sumy BTEX i sumy THM z wartości zmierzonych","methodology_en":"Determination of VOC by GC/FID method and calculation of the sum of BTEX and the sum of THM from the measured values","methodology_zh":"GC/FID法测定挥发性有机物及由测量值计算BTEX总和和三卤甲烷总和","methodology_cs":"Stanovení TOL metodou GC/FID a výpočet sumy BTEX a sumy THM z naměřených hodnot","parameters":[{"name":"Benzen","range":""},{"name":"toluen","range":""},{"name":"etylobenzen","range":""},{"name":"ksyleny","range":""},{"name":"styren","range":""},{"name":"izopropylobenzen","range":""},{"name":"cis-1,2-dichloroeten","range":""},{"name":"trichloroeten","range":""},{"name":"tetrachloroeten","range":""},{"name":"trichlorometan","range":""},{"name":"bromodichlorometan","range":""},{"name":"dibromochlorometan","range":""},{"name":"tribromometan","range":""},{"name":"1,2-dichloroetan","range":""},{"name":"dichlorometan","range":""}],"parameters_en":[{"name":"Benzene","range":""},{"name":"toluene","range":""},{"name":"ethylbenzene","range":""},{"name":"xylenes","range":""},{"name":"styrene","range":""},{"name":"isopropylbenzene","range":""},{"name":"cis-1,2-dichloroethene","range":""},{"name":"trichloroethene","range":""},{"name":"tetrachloroethene","range":""},{"name":"trichloromethane","range":""},{"name":"bromodichloromethane","range":""},{"name":"dibromochloromethane","range":""},{"name":"tribromomethane","range":""},{"name":"1,2-dichloroethane","range":""},{"name":"dichloromethane","range":""}],"parameters_zh":[{"name":"苯","range":""},{"name":"甲苯","range":""},{"name":"乙苯","range":""},{"name":"二甲苯","range":""},{"name":"苯乙烯","range":""},{"name":"异丙苯","range":""},{"name":"顺式-1,2-二氯乙烯","range":""},{"name":"三氯乙烯","range":""},{"name":"四氯乙烯","range":""},{"name":"三氯甲烷","range":""},{"name":"一溴二氯甲烷","range":""},{"name":"二溴一氯甲烷","range":""},{"name":"三溴甲烷","range":""},{"name":"1,2-二氯乙烷","range":""},{"name":"二氯甲烷","range":""}],"parameters_cs":[{"name":"Benzen","range":""},{"name":"toluen","range":""},{"name":"ethylbenzen","range":""},{"name":"xyleny","range":""},{"name":"styren","range":""},{"name":"isopropylbenzen","range":""},{"name":"cis-1,2-dichlorethen","range":""},{"name":"trichlorethen","range":""},{"name":"tetrachlorethen","range":""},{"name":"trichlormethan","range":""},{"name":"bromdichlormethan","range":""},{"name":"dibromchlormethan","range":""},{"name":"tribrommethan","range":""},{"name":"1,2-dichlorethan","range":""},{"name":"dichlormethan","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma BTEX","suma THM"],"computed_en":["sum of BTEX","sum of THM"],"computed_zh":["BTEX总和","三卤甲烷总和"],"computed_cs":["suma BTEX","suma THM"],"activity":"Oznaczanie LZO metodą GC/FID i obliczanie sumy BTEX i sumy THM z wartości zmierzonych\nZakres:\nBenzen\ntoluen\netylobenzen\nksyleny\nstyren\nizopropylobenzen\ncis-1,2-dichloroeten\ntrichloroeten\ntetrachloroeten\ntrichlorometan\nbromodichlorometan\ndibromochlorometan\ntribromometan\n1,2-dichloroetan\ndichlorometan","reference":"SOP AL-35 (ČSN EN ISO 15680)","norm_bases":["SOP AL-35","ČSN EN ISO 15680"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie LZO metodą GC/FID i obliczanie sumy BTEX i sumy THM z wartości zmierzonych Benzen  toluen  etylobenzen  ksyleny  styren  izopropylobenzen  cis-1,2-dichloroeten  trichloroeten  tetrachloroeten  trichlorometan  bromodichlorometan  dibromochlorometan  tribromometan  1,2-dichloroetan  dichlorometan  suma BTEX suma THM Pitná, podzemní, povrchová a odpadní voda Stanovení TOL metodou GC/FID a výpočet sumy BTEX a sumy THM z naměřených hodnot Benzen  toluen  ethylbenzen  xyleny  styren  isopropylbenzen  cis-1,2-dichlorethen  trichlorethen  tetrachlorethen  trichlormethan  bromdichlormethan  dibromchlormethan  tribrommethan  1,2-dichlorethan  dichlormethan  suma BTEX suma THM SOP AL-35 (ČSN EN ISO 15680) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie LZO metoda GC/FID i obliczanie sumy BTEX i sumy THM z wartosci zmierzonych Benzen  toluen  etylobenzen  ksyleny  styren  izopropylobenzen  cis-1,2-dichloroeten  trichloroeten  tetrachloroeten  trichlorometan  bromodichlorometan  dibromochlorometan  tribromometan  1,2-dichloroetan  dichlorometan  suma BTEX suma THM Pitna, podzemni, povrchova a odpadni voda Stanoveni TOL metodou GC/FID a vypocet sumy BTEX a sumy THM z namerenych hodnot Benzen  toluen  ethylbenzen  xyleny  styren  isopropylbenzen  cis-1,2-dichlorethen  trichlorethen  tetrachlorethen  trichlormethan  bromdichlormethan  dibromchlormethan  tribrommethan  1,2-dichlorethan  dichlormethan  suma BTEX suma THM SOP AL-35 (CSN EN ISO 15680)","search_en":"Drinking, ground, surface and waste water Determination of VOC by GC/FID method and calculation of the sum of BTEX and the sum of THM from the measured values Benzene  toluene  ethylbenzene  xylenes  styrene  isopropylbenzene  cis-1,2-dichloroethene  trichloroethene  tetrachloroethene  trichloromethane  bromodichloromethane  dibromochloromethane  tribromomethane  1,2-dichloroethane  dichloromethane  sum of BTEX sum of THM SOP AL-35 (ČSN EN ISO 15680)","search_zh":"饮用水、地下水、地表水和废水 GC/FID法测定挥发性有机物及由测量值计算BTEX总和和三卤甲烷总和 苯  甲苯  乙苯  二甲苯  苯乙烯  异丙苯  顺式-1,2-二氯乙烯  三氯乙烯  四氯乙烯  三氯甲烷  一溴二氯甲烷  二溴一氯甲烷  三溴甲烷  1,2-二氯乙烷  二氯甲烷  BTEX总和 三卤甲烷总和 SOP AL-35 (ČSN EN ISO 15680)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"32b12df6deebceb578d98ed3","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"42","test_object":"Wody podziemne","test_object_en":"Ground water","test_object_zh":"地下水","test_object_cs":"Podzemní voda","methodology":"Oznaczanie gazów atenuacyjnych metodą GC/FID headspace","methodology_en":"Determination of attenuation gases by GC/FID headspace method","methodology_zh":"顶空GC/FID法测定衰减气体","methodology_cs":"Stanovení atenuačních plynů metodou GC/FID headspace","parameters":[{"name":"Metan","range":""},{"name":"etan","range":""},{"name":"eten","range":""},{"name":"propan","range":""},{"name":"etyn","range":""}],"parameters_en":[{"name":"Methane","range":""},{"name":"ethane","range":""},{"name":"ethene","range":""},{"name":"propane","range":""},{"name":"ethyne","range":""}],"parameters_zh":[{"name":"甲烷","range":""},{"name":"乙烷","range":""},{"name":"乙烯","range":""},{"name":"丙烷","range":""},{"name":"乙炔","range":""}],"parameters_cs":[{"name":"Methan","range":""},{"name":"ethan","range":""},{"name":"ethen","range":""},{"name":"propan","range":""},{"name":"ethyn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gazów atenuacyjnych metodą GC/FID headspace\nZakres:\nMetan\netan\neten\npropan\netyn","reference":"SOP AL-36 (The Validation of Metodology in the Determination of Methane in Water, Lewin, K., Blakey, N.C., Cooke, D.A., 1990)","norm_bases":["SOP AL-36","The Validation of Metodology in the Determination of Methane in Water, Lewin, K., Blakey, N.C., Cooke, D.A., 1990"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Ground water – mineral, spa, mine water","note_zh":"地下水–矿泉水、温泉水、矿井水","note_cs":"Podzemní – minerální, lázeňská, důlní","search_text":"Wody podziemne Oznaczanie gazów atenuacyjnych metodą GC/FID headspace Metan  etan  eten  propan  etyn  Podzemní voda Stanovení atenuačních plynů metodou GC/FID headspace Methan  ethan  ethen  propan  ethyn  SOP AL-36 (The Validation of Metodology in the Determination of Methane in Water, Lewin, K., Blakey, N.C., Cooke, D.A., 1990) Wody podziemne Oznaczanie gazow atenuacyjnych metoda GC/FID headspace Metan  etan  eten  propan  etyn  Podzemni voda Stanoveni atenuacnich plynu metodou GC/FID headspace Methan  ethan  ethen  propan  ethyn  SOP AL-36 (The Validation of Metodology in the Determination of Methane in Water, Lewin, K., Blakey, N.C., Cooke, D.A., 1990)","search_en":"Ground water Determination of attenuation gases by GC/FID headspace method Methane  ethane  ethene  propane  ethyne  SOP AL-36 (The Validation of Metodology in the Determination of Methane in Water, Lewin, K., Blakey, N.C., Cooke, D.A., 1990)","search_zh":"地下水 顶空GC/FID法测定衰减气体 甲烷  乙烷  乙烯  丙烷  乙炔  SOP AL-36 (The Validation of Metodology in the Determination of Methane in Water, Lewin, K., Blakey, N.C., Cooke, D.A., 1990)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fcca62182f5e591d47bfb247","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"45","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice","methodology":"Oznaczanie niepolarnych substancji ekstrahowalnych metodą spektrometrii w podczerwieni (NELIR)","methodology_en":"Determination of nonpolar extractives by infrared spectrometry method (NELIR)","methodology_zh":"红外光谱法测定非极性可萃取物（NELIR）","methodology_cs":"Stanovení nepolárních extrahovatelných látek metodou infračervené spektrometrie (NELIR)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie niepolarnych substancji ekstrahowalnych metodą spektrometrii w podczerwieni (NELIR)","reference":"SOP AL-38 (ČSN 75 7505:1998)","norm_bases":["SOP AL-38","ČSN 75 7505:1998"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej Oznaczanie niepolarnych substancji ekstrahowalnych metodą spektrometrii w podczerwieni (NELIR) Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice Stanovení nepolárních extrahovatelných látek metodou infračervené spektrometrie (NELIR) SOP AL-38 (ČSN 75 7505:1998) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej Oznaczanie niepolarnych substancji ekstrahowalnych metoda spektrometrii w podczerwieni (NELIR) Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice Stanoveni nepolarnich extrahovatelnych latek metodou infracervene spektrometrie (NELIR) SOP AL-38 (CSN 75 7505:1998)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix Determination of nonpolar extractives by infrared spectrometry method (NELIR) SOP AL-38 (ČSN 75 7505:1998)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液 红外光谱法测定非极性可萃取物（NELIR） SOP AL-38 (ČSN 75 7505:1998)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"896d7602a1580679e7999e63","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"47","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie substancji ekstrahowalnych metodą spektrometrii w podczerwieni (ELIR)","methodology_en":"Determination of extractives by infrared spectrometry method (ELIR)","methodology_zh":"红外光谱法测定可萃取物（ELIR）","methodology_cs":"Stanovení extrahovatelných látek metodou infračervené spektrometrie (ELIR)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji ekstrahowalnych metodą spektrometrii w podczerwieni (ELIR)","reference":"SOP AL-39 (ČSN 75 7506)","norm_bases":["SOP AL-39","ČSN 75 7506"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie substancji ekstrahowalnych metodą spektrometrii w podczerwieni (ELIR) Pitná, podzemní, povrchová a odpadní voda Stanovení extrahovatelných látek metodou infračervené spektrometrie (ELIR) SOP AL-39 (ČSN 75 7506) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie substancji ekstrahowalnych metoda spektrometrii w podczerwieni (ELIR) Pitna, podzemni, povrchova a odpadni voda Stanoveni extrahovatelnych latek metodou infracervene spektrometrie (ELIR) SOP AL-39 (CSN 75 7506)","search_en":"Drinking, ground, surface and waste water Determination of extractives by infrared spectrometry method (ELIR) SOP AL-39 (ČSN 75 7506)","search_zh":"饮用水、地下水、地表水和废水 红外光谱法测定可萃取物（ELIR） SOP AL-39 (ČSN 75 7506)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d1f3ba7665da994bc4607d68","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"48","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice","methodology":"Oznaczanie zawartości węglowodorów C10 - C40 po ekstrakcji rozpuszczalnikiem metodą GC/FID","methodology_en":"Determination of the content of hydrocarbons C10 - C40 after solvent extraction by GC/FID method","methodology_zh":"溶剂萃取后GC/FID法测定C10–C40烃类含量","methodology_cs":"Stanovení obsahu uhlovodíků C10 - C40 po extrakci rozpouštědlem metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości węglowodorów C10 - C40 po ekstrakcji rozpuszczalnikiem metodą GC/FID","reference":"SOP AL-40 (ČSN EN ISO 9377-2)","norm_bases":["SOP AL-40","ČSN EN ISO 9377-2"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej Oznaczanie zawartości węglowodorów C10 - C40 po ekstrakcji rozpuszczalnikiem metodą GC/FID Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice Stanovení obsahu uhlovodíků C10 - C40 po extrakci rozpouštědlem metodou GC/FID SOP AL-40 (ČSN EN ISO 9377-2) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej Oznaczanie zawartosci weglowodorow C10 - C40 po ekstrakcji rozpuszczalnikiem metoda GC/FID Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice Stanoveni obsahu uhlovodiku C10 - C40 po extrakci rozpoustedlem metodou GC/FID SOP AL-40 (CSN EN ISO 9377-2)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix Determination of the content of hydrocarbons C10 - C40 after solvent extraction by GC/FID method SOP AL-40 (ČSN EN ISO 9377-2)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液 溶剂萃取后GC/FID法测定C10–C40烃类含量 SOP AL-40 (ČSN EN ISO 9377-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fe0012a8062ee2bc37177f1a","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"49","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie zawartości węglowodorów C10 - C40 po ekstrakcji rozpuszczalnikiem metodą GC/FID","methodology_en":"Determination of the content of hydrocarbons C10 - C40 after solvent extraction by GC/FID method","methodology_zh":"溶剂萃取后GC/FID法测定C10–C40烃类含量","methodology_cs":"Stanovení obsahu uhlovodíků C10 - C40 po extrakci rozpouštědlem metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości węglowodorów C10 - C40 po ekstrakcji rozpuszczalnikiem metodą GC/FID","reference":"SOP AL-40A (ČSN EN 14039; ČSN EN ISO 16703)","norm_bases":["SOP AL-40A","ČSN EN 14039","ČSN EN ISO 16703"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Matryce stałe – różne rodzaje próbek stałych gruntów, osadów dennych, kompostów, osadów, odpadów, gleby, konstrukcji budowlanych","note_en":"Solid matrices – various types of solid samples of soils, sediments, composts, sludge, waste, soil, building structures","note_zh":"固体基质–土、沉积物、堆肥、污泥、废物、土壤、建筑结构等各类固体样品","note_cs":"Pevné matrice – různé typy pevných vzorků zemin, sedimentů, kompostů, kalů, odpadů, půdy, stavebních konstrukcí","search_text":"Matryce stałe Oznaczanie zawartości węglowodorów C10 - C40 po ekstrakcji rozpuszczalnikiem metodą GC/FID Pevné matrice Stanovení obsahu uhlovodíků C10 - C40 po extrakci rozpouštědlem metodou GC/FID SOP AL-40A (ČSN EN 14039; ČSN EN ISO 16703) Matryce stale Oznaczanie zawartosci weglowodorow C10 - C40 po ekstrakcji rozpuszczalnikiem metoda GC/FID Pevne matrice Stanoveni obsahu uhlovodiku C10 - C40 po extrakci rozpoustedlem metodou GC/FID SOP AL-40A (CSN EN 14039; CSN EN ISO 16703)","search_en":"Solid matrices Determination of the content of hydrocarbons C10 - C40 after solvent extraction by GC/FID method SOP AL-40A (ČSN EN 14039; ČSN EN ISO 16703)","search_zh":"固体基质 溶剂萃取后GC/FID法测定C10–C40烃类含量 SOP AL-40A (ČSN EN 14039; ČSN EN ISO 16703)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"19d2191aebac3e9a25f42830","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"50","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie estrów kwasu ftalowego metodą GC/MS","methodology_en":"Determination of phthalic acid esters by GC/MS method","methodology_zh":"GC/MS法测定邻苯二甲酸酯","methodology_cs":"Stanovení esterů kyseliny ftalové metodou GC/MS","parameters":[{"name":"Ftalan di-n-butylu","range":""},{"name":"Ftalan bis(2-etyloheksylu)","range":""}],"parameters_en":[{"name":"Di-n-butyl phthalate","range":""},{"name":"bis(2-ethylhexyl) phthalate","range":""}],"parameters_zh":[{"name":"邻苯二甲酸二正丁酯","range":""},{"name":"邻苯二甲酸二(2-乙基己基)酯","range":""}],"parameters_cs":[{"name":"Di-n-butylftalát","range":""},{"name":"bis(2-ethylhexyl)ftalát","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie estrów kwasu ftalowego metodą GC/MS\nZakres:\nFtalan di-n-butylu\nFtalan bis(2-etyloheksylu)","reference":"SOP AL-41 (ČSN EN ISO 18856; EPA Method 8060)","norm_bases":["SOP AL-41","ČSN EN ISO 18856","EPA Method 8060"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie estrów kwasu ftalowego metodą GC/MS Ftalan di-n-butylu  Ftalan bis(2-etyloheksylu)  Pitná, podzemní, povrchová a odpadní voda Stanovení esterů kyseliny ftalové metodou GC/MS Di-n-butylftalát  bis(2-ethylhexyl)ftalát  SOP AL-41 (ČSN EN ISO 18856; EPA Method 8060) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie estrow kwasu ftalowego metoda GC/MS Ftalan di-n-butylu  Ftalan bis(2-etyloheksylu)  Pitna, podzemni, povrchova a odpadni voda Stanoveni esteru kyseliny ftalove metodou GC/MS Di-n-butylftalat  bis(2-ethylhexyl)ftalat  SOP AL-41 (CSN EN ISO 18856; EPA Method 8060)","search_en":"Drinking, ground, surface and waste water Determination of phthalic acid esters by GC/MS method Di-n-butyl phthalate  bis(2-ethylhexyl) phthalate  SOP AL-41 (ČSN EN ISO 18856; EPA Method 8060)","search_zh":"饮用水、地下水、地表水和废水 GC/MS法测定邻苯二甲酸酯 邻苯二甲酸二正丁酯  邻苯二甲酸二(2-乙基己基)酯  SOP AL-41 (ČSN EN ISO 18856; EPA Method 8060)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43d9b708e58f88035d3bf9a6","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"51","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice","methodology":"Oznaczanie PCB i OCP metodą GC/MS oraz obliczanie sumy PCB i sumy OCP z wartości zmierzonych","methodology_en":"Determination of PCB, OCP by GC/MS method and calculation of the sum of PCB and the sum of OCP from measured values","methodology_zh":"GC/MS法测定多氯联苯和有机氯农药及由测量值计算其总和","methodology_cs":"Stanovení PCB, OCP metodou GC/MS a výpočet sumy PCB a sumy OCP z naměřených hodnot","parameters":[{"name":"PCB – kongenery 28, 52, 101, 118, 138, 153, 180","range":""},{"name":"trichlorobenzeny","range":""},{"name":"heksachlorobenzen","range":""},{"name":"heptachlor","range":""},{"name":"epoksyd heptachloru","range":""},{"name":"DDD","range":""},{"name":"DDE","range":""},{"name":"DDT","range":""},{"name":"aldryna","range":""},{"name":"dieldryna","range":""},{"name":"α-HCH","range":""},{"name":"β-HCH","range":""},{"name":"γ-HCH (lindan)","range":""},{"name":"δ-HCH","range":""},{"name":"ε-HCH","range":""},{"name":"izodryna","range":""},{"name":"metoksychlor","range":""}],"parameters_en":[{"name":"PCB – congeners 28, 52, 101, 118, 138, 153, 180","range":""},{"name":"trichlorobenzenes","range":""},{"name":"hexachlorobenzene","range":""},{"name":"heptachlor","range":""},{"name":"heptachlor epoxide","range":""},{"name":"DDD","range":""},{"name":"DDE","range":""},{"name":"DDT","range":""},{"name":"aldrin","range":""},{"name":"dieldrin","range":""},{"name":"α-HCH","range":""},{"name":"β-HCH","range":""},{"name":"γ-HCH (lindane)","range":""},{"name":"δ-HCH","range":""},{"name":"ε-HCH","range":""},{"name":"isodrin","range":""},{"name":"methoxychlor","range":""}],"parameters_zh":[{"name":"多氯联苯–同系物28、52、101、118、138、153、180","range":""},{"name":"三氯苯","range":""},{"name":"六氯苯","range":""},{"name":"七氯","range":""},{"name":"环氧七氯","range":""},{"name":"滴滴滴","range":""},{"name":"滴滴伊","range":""},{"name":"滴滴涕","range":""},{"name":"艾氏剂","range":""},{"name":"狄氏剂","range":""},{"name":"α-六六六","range":""},{"name":"β-六六六","range":""},{"name":"γ-六六六（林丹）","range":""},{"name":"δ-六六六","range":""},{"name":"ε-六六六","range":""},{"name":"异艾氏剂","range":""},{"name":"甲氧滴滴涕","range":""}],"parameters_cs":[{"name":"PCB – kongenery 28, 52, 101, 118, 138, 153, 180","range":""},{"name":"trichlorbenzeny","range":""},{"name":"hexachlorbenzen","range":""},{"name":"heptachlor","range":""},{"name":"heptachlorepoxid","range":""},{"name":"DDD","range":""},{"name":"DDE","range":""},{"name":"DDT","range":""},{"name":"aldrin","range":""},{"name":"dieldrin","range":""},{"name":"α-HCH","range":""},{"name":"β-HCH","range":""},{"name":"γ-HCH (lindan)","range":""},{"name":"δ-HCH","range":""},{"name":"ε-HCH","range":""},{"name":"isodrin","range":""},{"name":"methoxychlor","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma PCB","obliczeniowo: sumy wybranych OCP"],"computed_en":["sum of PCB","by calculation: sums of selected OCP"],"computed_zh":["多氯联苯总和","计算：所选有机氯农药总和"],"computed_cs":["suma PCB","výpočtem: sumy vybraných OCP"],"activity":"Oznaczanie PCB i OCP metodą GC/MS oraz obliczanie sumy PCB i sumy OCP z wartości zmierzonych\nZakres:\nPCB – kongenery 28, 52, 101, 118, 138, 153, 180\ntrichlorobenzeny\nheksachlorobenzen\nheptachlor\nepoksyd heptachloru\nDDD\nDDE\nDDT\naldryna\ndieldryna\nα-HCH\nβ-HCH\nγ-HCH (lindan)\nδ-HCH\nε-HCH\nizodryna\nmetoksychlor","reference":"SOP AL-42 (ČSN EN ISO 6468; EPA Method 680)","norm_bases":["SOP AL-42","ČSN EN ISO 6468","EPA Method 680"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej Oznaczanie PCB i OCP metodą GC/MS oraz obliczanie sumy PCB i sumy OCP z wartości zmierzonych PCB – kongenery 28, 52, 101, 118, 138, 153, 180  trichlorobenzeny  heksachlorobenzen  heptachlor  epoksyd heptachloru  DDD  DDE  DDT  aldryna  dieldryna  α-HCH  β-HCH  γ-HCH (lindan)  δ-HCH  ε-HCH  izodryna  metoksychlor  suma PCB obliczeniowo: sumy wybranych OCP Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice Stanovení PCB, OCP metodou GC/MS a výpočet sumy PCB a sumy OCP z naměřených hodnot PCB – kongenery 28, 52, 101, 118, 138, 153, 180  trichlorbenzeny  hexachlorbenzen  heptachlor  heptachlorepoxid  DDD  DDE  DDT  aldrin  dieldrin  α-HCH  β-HCH  γ-HCH (lindan)  δ-HCH  ε-HCH  isodrin  methoxychlor  suma PCB výpočtem: sumy vybraných OCP SOP AL-42 (ČSN EN ISO 6468; EPA Method 680) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej Oznaczanie PCB i OCP metoda GC/MS oraz obliczanie sumy PCB i sumy OCP z wartosci zmierzonych PCB – kongenery 28, 52, 101, 118, 138, 153, 180  trichlorobenzeny  heksachlorobenzen  heptachlor  epoksyd heptachloru  DDD  DDE  DDT  aldryna  dieldryna  α-HCH  β-HCH  γ-HCH (lindan)  δ-HCH  ε-HCH  izodryna  metoksychlor  suma PCB obliczeniowo: sumy wybranych OCP Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice Stanoveni PCB, OCP metodou GC/MS a vypocet sumy PCB a sumy OCP z namerenych hodnot PCB – kongenery 28, 52, 101, 118, 138, 153, 180  trichlorbenzeny  hexachlorbenzen  heptachlor  heptachlorepoxid  DDD  DDE  DDT  aldrin  dieldrin  α-HCH  β-HCH  γ-HCH (lindan)  δ-HCH  ε-HCH  isodrin  methoxychlor  suma PCB vypoctem: sumy vybranych OCP SOP AL-42 (CSN EN ISO 6468; EPA Method 680)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix Determination of PCB, OCP by GC/MS method and calculation of the sum of PCB and the sum of OCP from measured values PCB – congeners 28, 52, 101, 118, 138, 153, 180  trichlorobenzenes  hexachlorobenzene  heptachlor  heptachlor epoxide  DDD  DDE  DDT  aldrin  dieldrin  α-HCH  β-HCH  γ-HCH (lindane)  δ-HCH  ε-HCH  isodrin  methoxychlor  sum of PCB by calculation: sums of selected OCP SOP AL-42 (ČSN EN ISO 6468; EPA Method 680)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液 GC/MS法测定多氯联苯和有机氯农药及由测量值计算其总和 多氯联苯–同系物28、52、101、118、138、153、180  三氯苯  六氯苯  七氯  环氧七氯  滴滴滴  滴滴伊  滴滴涕  艾氏剂  狄氏剂  α-六六六  β-六六六  γ-六六六（林丹）  δ-六六六  ε-六六六  异艾氏剂  甲氧滴滴涕  多氯联苯总和 计算：所选有机氯农药总和 SOP AL-42 (ČSN EN ISO 6468; EPA Method 680)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"530ca19105bb4bb5fa0142d5","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"52","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie PCB i OCP metodą GC/MS oraz obliczanie sumy PCB i sumy OCP z wartości zmierzonych","methodology_en":"Determination of PCB, OCP by GC/MS method and calculation of the sum of PCB and the sum of OCP from measured values","methodology_zh":"GC/MS法测定多氯联苯和有机氯农药及由测量值计算其总和","methodology_cs":"Stanovení PCB, OCP metodou GC/MS a výpočet sumy PCB a sumy OCP z naměřených hodnot","parameters":[{"name":"PCB – kongenery 28, 52, 101, 118, 138, 153, 180","range":""},{"name":"trichlorobenzeny","range":""},{"name":"heksachlorobenzen","range":""},{"name":"heptachlor","range":""},{"name":"epoksyd heptachloru","range":""},{"name":"DDD","range":""},{"name":"DDE","range":""},{"name":"DDT","range":""},{"name":"aldryna","range":""},{"name":"dieldryna","range":""},{"name":"α-HCH","range":""},{"name":"β-HCH","range":""},{"name":"γ-HCH (lindan)","range":""},{"name":"δ-HCH","range":""},{"name":"ε-HCH","range":""},{"name":"izodryna","range":""},{"name":"metoksychlor","range":""}],"parameters_en":[{"name":"PCB – congeners 28, 52, 101, 118, 138, 153, 180","range":""},{"name":"trichlorobenzenes","range":""},{"name":"hexachlorobenzene","range":""},{"name":"heptachlor","range":""},{"name":"heptachlor epoxide","range":""},{"name":"DDD","range":""},{"name":"DDE","range":""},{"name":"DDT","range":""},{"name":"aldrin","range":""},{"name":"dieldrin","range":""},{"name":"α-HCH","range":""},{"name":"β-HCH","range":""},{"name":"γ-HCH (lindane)","range":""},{"name":"δ-HCH","range":""},{"name":"ε-HCH","range":""},{"name":"isodrin","range":""},{"name":"methoxychlor","range":""}],"parameters_zh":[{"name":"多氯联苯–同系物28、52、101、118、138、153、180","range":""},{"name":"三氯苯","range":""},{"name":"六氯苯","range":""},{"name":"七氯","range":""},{"name":"环氧七氯","range":""},{"name":"滴滴滴","range":""},{"name":"滴滴伊","range":""},{"name":"滴滴涕","range":""},{"name":"艾氏剂","range":""},{"name":"狄氏剂","range":""},{"name":"α-六六六","range":""},{"name":"β-六六六","range":""},{"name":"γ-六六六（林丹）","range":""},{"name":"δ-六六六","range":""},{"name":"ε-六六六","range":""},{"name":"异艾氏剂","range":""},{"name":"甲氧滴滴涕","range":""}],"parameters_cs":[{"name":"PCB – kongenery 28, 52, 101, 118, 138, 153, 180","range":""},{"name":"trichlorbenzeny","range":""},{"name":"hexachlorbenzen","range":""},{"name":"heptachlor","range":""},{"name":"heptachlorepoxid","range":""},{"name":"DDD","range":""},{"name":"DDE","range":""},{"name":"DDT","range":""},{"name":"aldrin","range":""},{"name":"dieldrin","range":""},{"name":"α-HCH","range":""},{"name":"β-HCH","range":""},{"name":"γ-HCH (lindan)","range":""},{"name":"δ-HCH","range":""},{"name":"ε-HCH","range":""},{"name":"isodrin","range":""},{"name":"methoxychlor","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma PCB","obliczeniowo: sumy wybranych OCP"],"computed_en":["sum of PCB","by calculation: sums of selected OCP"],"computed_zh":["多氯联苯总和","计算：所选有机氯农药总和"],"computed_cs":["suma PCB","výpočtem: sumy vybraných OCP"],"activity":"Oznaczanie PCB i OCP metodą GC/MS oraz obliczanie sumy PCB i sumy OCP z wartości zmierzonych\nZakres:\nPCB – kongenery 28, 52, 101, 118, 138, 153, 180\ntrichlorobenzeny\nheksachlorobenzen\nheptachlor\nepoksyd heptachloru\nDDD\nDDE\nDDT\naldryna\ndieldryna\nα-HCH\nβ-HCH\nγ-HCH (lindan)\nδ-HCH\nε-HCH\nizodryna\nmetoksychlor","reference":"SOP AL-42A (ČSN EN 17322; EPA Method 680)","norm_bases":["SOP AL-42A","ČSN EN 17322","EPA Method 680"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Matryce stałe – różne rodzaje próbek stałych gruntów, osadów dennych, kompostów, osadów, odpadów, gleby, konstrukcji budowlanych","note_en":"Solid matrices – various types of solid samples of soils, sediments, composts, sludge, waste, soil, building structures","note_zh":"固体基质–土、沉积物、堆肥、污泥、废物、土壤、建筑结构等各类固体样品","note_cs":"Pevné matrice – různé typy pevných vzorků zemin, sedimentů, kompostů, kalů, odpadů, půdy, stavebních konstrukcí","search_text":"Matryce stałe Oznaczanie PCB i OCP metodą GC/MS oraz obliczanie sumy PCB i sumy OCP z wartości zmierzonych PCB – kongenery 28, 52, 101, 118, 138, 153, 180  trichlorobenzeny  heksachlorobenzen  heptachlor  epoksyd heptachloru  DDD  DDE  DDT  aldryna  dieldryna  α-HCH  β-HCH  γ-HCH (lindan)  δ-HCH  ε-HCH  izodryna  metoksychlor  suma PCB obliczeniowo: sumy wybranych OCP Pevné matrice Stanovení PCB, OCP metodou GC/MS a výpočet sumy PCB a sumy OCP z naměřených hodnot PCB – kongenery 28, 52, 101, 118, 138, 153, 180  trichlorbenzeny  hexachlorbenzen  heptachlor  heptachlorepoxid  DDD  DDE  DDT  aldrin  dieldrin  α-HCH  β-HCH  γ-HCH (lindan)  δ-HCH  ε-HCH  isodrin  methoxychlor  suma PCB výpočtem: sumy vybraných OCP SOP AL-42A (ČSN EN 17322; EPA Method 680) Matryce stale Oznaczanie PCB i OCP metoda GC/MS oraz obliczanie sumy PCB i sumy OCP z wartosci zmierzonych PCB – kongenery 28, 52, 101, 118, 138, 153, 180  trichlorobenzeny  heksachlorobenzen  heptachlor  epoksyd heptachloru  DDD  DDE  DDT  aldryna  dieldryna  α-HCH  β-HCH  γ-HCH (lindan)  δ-HCH  ε-HCH  izodryna  metoksychlor  suma PCB obliczeniowo: sumy wybranych OCP Pevne matrice Stanoveni PCB, OCP metodou GC/MS a vypocet sumy PCB a sumy OCP z namerenych hodnot PCB – kongenery 28, 52, 101, 118, 138, 153, 180  trichlorbenzeny  hexachlorbenzen  heptachlor  heptachlorepoxid  DDD  DDE  DDT  aldrin  dieldrin  α-HCH  β-HCH  γ-HCH (lindan)  δ-HCH  ε-HCH  isodrin  methoxychlor  suma PCB vypoctem: sumy vybranych OCP SOP AL-42A (CSN EN 17322; EPA Method 680)","search_en":"Solid matrices Determination of PCB, OCP by GC/MS method and calculation of the sum of PCB and the sum of OCP from measured values PCB – congeners 28, 52, 101, 118, 138, 153, 180  trichlorobenzenes  hexachlorobenzene  heptachlor  heptachlor epoxide  DDD  DDE  DDT  aldrin  dieldrin  α-HCH  β-HCH  γ-HCH (lindane)  δ-HCH  ε-HCH  isodrin  methoxychlor  sum of PCB by calculation: sums of selected OCP SOP AL-42A (ČSN EN 17322; EPA Method 680)","search_zh":"固体基质 GC/MS法测定多氯联苯和有机氯农药及由测量值计算其总和 多氯联苯–同系物28、52、101、118、138、153、180  三氯苯  六氯苯  七氯  环氧七氯  滴滴滴  滴滴伊  滴滴涕  艾氏剂  狄氏剂  α-六六六  β-六六六  γ-六六六（林丹）  δ-六六六  ε-六六六  异艾氏剂  甲氧滴滴涕  多氯联苯总和 计算：所选有机氯农药总和 SOP AL-42A (ČSN EN 17322; EPA Method 680)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d5161d1ddfee3a8bdadbbde8","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"53","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice","methodology":"Oznaczanie WWA metodą HPLC/FLUD, DAD i obliczanie sumy WWA z wartości zmierzonych","methodology_en":"Determination of PAH by HPLC/FLUD, DAD method and calculation of the sum of PAH from measured values","methodology_zh":"HPLC/FLUD、DAD法测定多环芳烃及由测量值计算其总和","methodology_cs":"Stanovení PAU metodou HPLC/FLUD, DAD a výpočet sumy PAU z naměřených hodnot","parameters":[{"name":"Naftalen","range":""},{"name":"acenaftylen","range":""},{"name":"acenaften","range":""},{"name":"fluoren","range":""},{"name":"fenantren","range":""},{"name":"antracen","range":""},{"name":"fluoranten","range":""},{"name":"piren","range":""},{"name":"benzo(a)antracen","range":""},{"name":"chryzen","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"benzo(a)piren","range":""},{"name":"dibenzo(a,h)antracen","range":""},{"name":"benzo(ghi)perylen","range":""},{"name":"indeno(1,2,3-cd)piren","range":""}],"parameters_en":[{"name":"Naphthalene","range":""},{"name":"acenaphthylene","range":""},{"name":"acenaphthene","range":""},{"name":"fluorene","range":""},{"name":"phenanthrene","range":""},{"name":"anthracene","range":""},{"name":"fluoranthene","range":""},{"name":"pyrene","range":""},{"name":"benzo(a)anthracene","range":""},{"name":"chrysene","range":""},{"name":"benzo(b)fluoranthene","range":""},{"name":"benzo(k)fluoranthene","range":""},{"name":"benzo(a)pyrene","range":""},{"name":"dibenzo(a,h)anthracene","range":""},{"name":"benzo(ghi)perylene","range":""},{"name":"indeno(1,2,3-cd)pyrene","range":""}],"parameters_zh":[{"name":"萘","range":""},{"name":"苊烯","range":""},{"name":"苊","range":""},{"name":"芴","range":""},{"name":"菲","range":""},{"name":"蒽","range":""},{"name":"荧蒽","range":""},{"name":"芘","range":""},{"name":"苯并(a)蒽","range":""},{"name":"䓛","range":""},{"name":"苯并(b)荧蒽","range":""},{"name":"苯并(k)荧蒽","range":""},{"name":"苯并(a)芘","range":""},{"name":"二苯并(a,h)蒽","range":""},{"name":"苯并(ghi)苝","range":""},{"name":"茚并(1,2,3-cd)芘","range":""}],"parameters_cs":[{"name":"Naftalen","range":""},{"name":"acenaftylen","range":""},{"name":"acenaften","range":""},{"name":"fluoren","range":""},{"name":"fenanthren","range":""},{"name":"anthracen","range":""},{"name":"fluoranthen","range":""},{"name":"pyren","range":""},{"name":"benzo(a)anthracen","range":""},{"name":"chrysen","range":""},{"name":"benzo(b)fluoranthen","range":""},{"name":"benzo(k)fluoranthen","range":""},{"name":"benzo(a)pyren","range":""},{"name":"dibenzo(a,h)anthracen","range":""},{"name":"benzo(ghi)perylen","range":""},{"name":"indeno(1,2,3-cd)pyren","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["obliczeniowo: sumy wybranych WWA"],"computed_en":["by calculation: sums of selected PAH"],"computed_zh":["计算：所选多环芳烃总和"],"computed_cs":["výpočtem: sumy vybraných PAU"],"activity":"Oznaczanie WWA metodą HPLC/FLUD, DAD i obliczanie sumy WWA z wartości zmierzonych\nZakres:\nNaftalen\nacenaftylen\nacenaften\nfluoren\nfenantren\nantracen\nfluoranten\npiren\nbenzo(a)antracen\nchryzen\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a)piren\ndibenzo(a,h)antracen\nbenzo(ghi)perylen\nindeno(1,2,3-cd)piren","reference":"SOP AL-43 (ČSN EN ISO 17993)","norm_bases":["SOP AL-43","ČSN EN ISO 17993"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej Oznaczanie WWA metodą HPLC/FLUD, DAD i obliczanie sumy WWA z wartości zmierzonych Naftalen  acenaftylen  acenaften  fluoren  fenantren  antracen  fluoranten  piren  benzo(a)antracen  chryzen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)piren  dibenzo(a,h)antracen  benzo(ghi)perylen  indeno(1,2,3-cd)piren  obliczeniowo: sumy wybranych WWA Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice Stanovení PAU metodou HPLC/FLUD, DAD a výpočet sumy PAU z naměřených hodnot Naftalen  acenaftylen  acenaften  fluoren  fenanthren  anthracen  fluoranthen  pyren  benzo(a)anthracen  chrysen  benzo(b)fluoranthen  benzo(k)fluoranthen  benzo(a)pyren  dibenzo(a,h)anthracen  benzo(ghi)perylen  indeno(1,2,3-cd)pyren  výpočtem: sumy vybraných PAU SOP AL-43 (ČSN EN ISO 17993) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej Oznaczanie WWA metoda HPLC/FLUD, DAD i obliczanie sumy WWA z wartosci zmierzonych Naftalen  acenaftylen  acenaften  fluoren  fenantren  antracen  fluoranten  piren  benzo(a)antracen  chryzen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)piren  dibenzo(a,h)antracen  benzo(ghi)perylen  indeno(1,2,3-cd)piren  obliczeniowo: sumy wybranych WWA Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice Stanoveni PAU metodou HPLC/FLUD, DAD a vypocet sumy PAU z namerenych hodnot Naftalen  acenaftylen  acenaften  fluoren  fenanthren  anthracen  fluoranthen  pyren  benzo(a)anthracen  chrysen  benzo(b)fluoranthen  benzo(k)fluoranthen  benzo(a)pyren  dibenzo(a,h)anthracen  benzo(ghi)perylen  indeno(1,2,3-cd)pyren  vypoctem: sumy vybranych PAU SOP AL-43 (CSN EN ISO 17993)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix Determination of PAH by HPLC/FLUD, DAD method and calculation of the sum of PAH from measured values Naphthalene  acenaphthylene  acenaphthene  fluorene  phenanthrene  anthracene  fluoranthene  pyrene  benzo(a)anthracene  chrysene  benzo(b)fluoranthene  benzo(k)fluoranthene  benzo(a)pyrene  dibenzo(a,h)anthracene  benzo(ghi)perylene  indeno(1,2,3-cd)pyrene  by calculation: sums of selected PAH SOP AL-43 (ČSN EN ISO 17993)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液 HPLC/FLUD、DAD法测定多环芳烃及由测量值计算其总和 萘  苊烯  苊  芴  菲  蒽  荧蒽  芘  苯并(a)蒽  䓛  苯并(b)荧蒽  苯并(k)荧蒽  苯并(a)芘  二苯并(a,h)蒽  苯并(ghi)苝  茚并(1,2,3-cd)芘  计算：所选多环芳烃总和 SOP AL-43 (ČSN EN ISO 17993)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dde27cd9024ccbcf51d21711","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"54","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie WWA metodą HPLC/FLUD, DAD i obliczanie sumy WWA z wartości zmierzonych","methodology_en":"Determination of PAH by HPLC/FLUD, DAD method and calculation of the sum of PAH from measured values","methodology_zh":"HPLC/FLUD、DAD法测定多环芳烃及由测量值计算其总和","methodology_cs":"Stanovení PAU metodou HPLC/FLUD, DAD a výpočet sumy PAU z naměřených hodnot","parameters":[{"name":"Naftalen","range":""},{"name":"acenaftylen","range":""},{"name":"acenaften","range":""},{"name":"fluoren","range":""},{"name":"fenantren","range":""},{"name":"antracen","range":""},{"name":"fluoranten","range":""},{"name":"piren","range":""},{"name":"benzo(a)antracen","range":""},{"name":"chryzen","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"benzo(a)piren","range":""},{"name":"dibenzo(a,h)antracen","range":""},{"name":"benzo(ghi)perylen","range":""},{"name":"indeno(1,2,3-cd)piren","range":""}],"parameters_en":[{"name":"Naphthalene","range":""},{"name":"acenaphthylene","range":""},{"name":"acenaphthene","range":""},{"name":"fluorene","range":""},{"name":"phenanthrene","range":""},{"name":"anthracene","range":""},{"name":"fluoranthene","range":""},{"name":"pyrene","range":""},{"name":"benzo(a)anthracene","range":""},{"name":"chrysene","range":""},{"name":"benzo(b)fluoranthene","range":""},{"name":"benzo(k)fluoranthene","range":""},{"name":"benzo(a)pyrene","range":""},{"name":"dibenzo(a,h)anthracene","range":""},{"name":"benzo(ghi)perylene","range":""},{"name":"indeno(1,2,3-cd)pyrene","range":""}],"parameters_zh":[{"name":"萘","range":""},{"name":"苊烯","range":""},{"name":"苊","range":""},{"name":"芴","range":""},{"name":"菲","range":""},{"name":"蒽","range":""},{"name":"荧蒽","range":""},{"name":"芘","range":""},{"name":"苯并(a)蒽","range":""},{"name":"䓛","range":""},{"name":"苯并(b)荧蒽","range":""},{"name":"苯并(k)荧蒽","range":""},{"name":"苯并(a)芘","range":""},{"name":"二苯并(a,h)蒽","range":""},{"name":"苯并(ghi)苝","range":""},{"name":"茚并(1,2,3-cd)芘","range":""}],"parameters_cs":[{"name":"Naftalen","range":""},{"name":"acenaftylen","range":""},{"name":"acenaften","range":""},{"name":"fluoren","range":""},{"name":"fenanthren","range":""},{"name":"anthracen","range":""},{"name":"fluoranthen","range":""},{"name":"pyren","range":""},{"name":"benzo(a)anthracen","range":""},{"name":"chrysen","range":""},{"name":"benzo(b)fluoranthen","range":""},{"name":"benzo(k)fluoranthen","range":""},{"name":"benzo(a)pyren","range":""},{"name":"dibenzo(a,h)anthracen","range":""},{"name":"benzo(ghi)perylen","range":""},{"name":"indeno(1,2,3-cd)pyren","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["obliczeniowo: sumy wybranych WWA"],"computed_en":["by calculation: sums of selected PAH"],"computed_zh":["计算：所选多环芳烃总和"],"computed_cs":["výpočtem: sumy vybraných PAU"],"activity":"Oznaczanie WWA metodą HPLC/FLUD, DAD i obliczanie sumy WWA z wartości zmierzonych\nZakres:\nNaftalen\nacenaftylen\nacenaften\nfluoren\nfenantren\nantracen\nfluoranten\npiren\nbenzo(a)antracen\nchryzen\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a)piren\ndibenzo(a,h)antracen\nbenzo(ghi)perylen\nindeno(1,2,3-cd)piren","reference":"SOP AL-43A (ČSN EN 17503)","norm_bases":["SOP AL-43A","ČSN EN 17503"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Matryce stałe – różne rodzaje próbek stałych gruntów, osadów dennych, kompostów, osadów, odpadów, gleby, konstrukcji budowlanych, mieszanka asfaltowa, makadam penetrowany","note_en":"Solid matrices – various types of solid samples of soils, sediments, composts, sludge, waste, soil, building structures, asphalt mixture, penetration macadam","note_zh":"固体基质–土、沉积物、堆肥、污泥、废物、土壤、建筑结构、沥青混合料、灌入式碎石等各类固体样品","note_cs":"Pevné matrice – různé typy pevných vzorků zemin, sedimentů, kompostů, kalů, odpadů, půdy, stavebních konstrukcí, asfaltová směs, penetrační makadam","search_text":"Matryce stałe Oznaczanie WWA metodą HPLC/FLUD, DAD i obliczanie sumy WWA z wartości zmierzonych Naftalen  acenaftylen  acenaften  fluoren  fenantren  antracen  fluoranten  piren  benzo(a)antracen  chryzen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)piren  dibenzo(a,h)antracen  benzo(ghi)perylen  indeno(1,2,3-cd)piren  obliczeniowo: sumy wybranych WWA Pevné matrice Stanovení PAU metodou HPLC/FLUD, DAD a výpočet sumy PAU z naměřených hodnot Naftalen  acenaftylen  acenaften  fluoren  fenanthren  anthracen  fluoranthen  pyren  benzo(a)anthracen  chrysen  benzo(b)fluoranthen  benzo(k)fluoranthen  benzo(a)pyren  dibenzo(a,h)anthracen  benzo(ghi)perylen  indeno(1,2,3-cd)pyren  výpočtem: sumy vybraných PAU SOP AL-43A (ČSN EN 17503) Matryce stale Oznaczanie WWA metoda HPLC/FLUD, DAD i obliczanie sumy WWA z wartosci zmierzonych Naftalen  acenaftylen  acenaften  fluoren  fenantren  antracen  fluoranten  piren  benzo(a)antracen  chryzen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)piren  dibenzo(a,h)antracen  benzo(ghi)perylen  indeno(1,2,3-cd)piren  obliczeniowo: sumy wybranych WWA Pevne matrice Stanoveni PAU metodou HPLC/FLUD, DAD a vypocet sumy PAU z namerenych hodnot Naftalen  acenaftylen  acenaften  fluoren  fenanthren  anthracen  fluoranthen  pyren  benzo(a)anthracen  chrysen  benzo(b)fluoranthen  benzo(k)fluoranthen  benzo(a)pyren  dibenzo(a,h)anthracen  benzo(ghi)perylen  indeno(1,2,3-cd)pyren  vypoctem: sumy vybranych PAU SOP AL-43A (CSN EN 17503)","search_en":"Solid matrices Determination of PAH by HPLC/FLUD, DAD method and calculation of the sum of PAH from measured values Naphthalene  acenaphthylene  acenaphthene  fluorene  phenanthrene  anthracene  fluoranthene  pyrene  benzo(a)anthracene  chrysene  benzo(b)fluoranthene  benzo(k)fluoranthene  benzo(a)pyrene  dibenzo(a,h)anthracene  benzo(ghi)perylene  indeno(1,2,3-cd)pyrene  by calculation: sums of selected PAH SOP AL-43A (ČSN EN 17503)","search_zh":"固体基质 HPLC/FLUD、DAD法测定多环芳烃及由测量值计算其总和 萘  苊烯  苊  芴  菲  蒽  荧蒽  芘  苯并(a)蒽  䓛  苯并(b)荧蒽  苯并(k)荧蒽  苯并(a)芘  二苯并(a,h)蒽  苯并(ghi)苝  茚并(1,2,3-cd)芘  计算：所选多环芳烃总和 SOP AL-43A (ČSN EN 17503)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a822b60823f818b87b8428e0","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"55","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie pestycydów metodą LC-MS","methodology_en":"Determination of pesticides by LC-MS method","methodology_zh":"LC-MS法测定农药","methodology_cs":"Stanovení pesticidů metodou LC-MS","parameters":[{"name":"Ametryna","range":""},{"name":"atraton","range":""},{"name":"atrazyna","range":""},{"name":"2-hydroksyatrazyna","range":""},{"name":"chlorydazon","range":""},{"name":"chlorydazon-desfenyl","range":""},{"name":"prometon","range":""},{"name":"prometryna","range":""},{"name":"propazyna","range":""},{"name":"sekbumeton","range":""},{"name":"symazyna","range":""},{"name":"2-hydroksysymazyna","range":""},{"name":"symetryna","range":""},{"name":"terbutylazyna","range":""},{"name":"terbutryna","range":""}],"parameters_en":[{"name":"Ametryn","range":""},{"name":"atraton","range":""},{"name":"atrazine","range":""},{"name":"atrazine-2-hydroxy","range":""},{"name":"chloridazon","range":""},{"name":"chloridazon-desphenyl","range":""},{"name":"prometon","range":""},{"name":"prometryn","range":""},{"name":"propazine","range":""},{"name":"secbumeton","range":""},{"name":"simazine","range":""},{"name":"simazine-2-hydroxy","range":""},{"name":"simetryn","range":""},{"name":"terbuthylazine","range":""},{"name":"terbutryn","range":""}],"parameters_zh":[{"name":"莠灭净","range":""},{"name":"阿特拉通","range":""},{"name":"莠去津","range":""},{"name":"2-羟基莠去津","range":""},{"name":"氯草敏","range":""},{"name":"去苯基氯草敏","range":""},{"name":"扑灭通","range":""},{"name":"扑草净","range":""},{"name":"扑灭津","range":""},{"name":"仲丁通","range":""},{"name":"西玛津","range":""},{"name":"2-羟基西玛津","range":""},{"name":"西草净","range":""},{"name":"特丁津","range":""},{"name":"特丁净","range":""}],"parameters_cs":[{"name":"Ametryn","range":""},{"name":"atraton","range":""},{"name":"atrazin","range":""},{"name":"atrazin-2-hydroxy","range":""},{"name":"chloridazon","range":""},{"name":"chloridazon-desphenyl","range":""},{"name":"prometon","range":""},{"name":"prometryn","range":""},{"name":"propazin","range":""},{"name":"secbumeton","range":""},{"name":"simazin","range":""},{"name":"simazin-2-hydroxy","range":""},{"name":"simetryn","range":""},{"name":"terbutylazin","range":""},{"name":"terbutryn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pestycydów metodą LC-MS\nZakres:\nAmetryna\natraton\natrazyna\n2-hydroksyatrazyna\nchlorydazon\nchlorydazon-desfenyl\nprometon\nprometryna\npropazyna\nsekbumeton\nsymazyna\n2-hydroksysymazyna\nsymetryna\nterbutylazyna\nterbutryna","reference":"SOP AL-44 (EPA Method 535; EPA Method 1694)","norm_bases":["SOP AL-44","EPA Method 535","EPA Method 1694"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie pestycydów metodą LC-MS Ametryna  atraton  atrazyna  2-hydroksyatrazyna  chlorydazon  chlorydazon-desfenyl  prometon  prometryna  propazyna  sekbumeton  symazyna  2-hydroksysymazyna  symetryna  terbutylazyna  terbutryna  Pitná, podzemní, povrchová a odpadní voda Stanovení pesticidů metodou LC-MS Ametryn  atraton  atrazin  atrazin-2-hydroxy  chloridazon  chloridazon-desphenyl  prometon  prometryn  propazin  secbumeton  simazin  simazin-2-hydroxy  simetryn  terbutylazin  terbutryn  SOP AL-44 (EPA Method 535; EPA Method 1694) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie pestycydow metoda LC-MS Ametryna  atraton  atrazyna  2-hydroksyatrazyna  chlorydazon  chlorydazon-desfenyl  prometon  prometryna  propazyna  sekbumeton  symazyna  2-hydroksysymazyna  symetryna  terbutylazyna  terbutryna  Pitna, podzemni, povrchova a odpadni voda Stanoveni pesticidu metodou LC-MS Ametryn  atraton  atrazin  atrazin-2-hydroxy  chloridazon  chloridazon-desphenyl  prometon  prometryn  propazin  secbumeton  simazin  simazin-2-hydroxy  simetryn  terbutylazin  terbutryn  SOP AL-44 (EPA Method 535; EPA Method 1694)","search_en":"Drinking, ground, surface and waste water Determination of pesticides by LC-MS method Ametryn  atraton  atrazine  atrazine-2-hydroxy  chloridazon  chloridazon-desphenyl  prometon  prometryn  propazine  secbumeton  simazine  simazine-2-hydroxy  simetryn  terbuthylazine  terbutryn  SOP AL-44 (EPA Method 535; EPA Method 1694)","search_zh":"饮用水、地下水、地表水和废水 LC-MS法测定农药 莠灭净  阿特拉通  莠去津  2-羟基莠去津  氯草敏  去苯基氯草敏  扑灭通  扑草净  扑灭津  仲丁通  西玛津  2-羟基西玛津  西草净  特丁津  特丁净  SOP AL-44 (EPA Method 535; EPA Method 1694)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d9456600eb858ee8adbca843","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"56","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie suchej masy próbki stałej metodą wagową i wilgotności obliczeniowo z wartości zmierzonych","methodology_en":"Determination of dry matter of a solid sample by gravimetry and moisture by calculation from measured values","methodology_zh":"重量法测定固体样品干物质及由测量值计算水分","methodology_cs":"Stanovení sušiny pevného vzorku gravimetricky a vlhkosti výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie suchej masy próbki stałej metodą wagową i wilgotności obliczeniowo z wartości zmierzonych","reference":"SOP AL-45 (ČSN EN 15934)","norm_bases":["SOP AL-45","ČSN EN 15934"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Matryce stałe – różne rodzaje próbek stałych gruntów, osadów dennych, kompostów, osadów, odpadów, gleby, konstrukcji budowlanych","note_en":"Solid matrices – various types of solid samples of soils, sediments, composts, sludge, waste, soil, building structures","note_zh":"固体基质–土、沉积物、堆肥、污泥、废物、土壤、建筑结构等各类固体样品","note_cs":"Pevné matrice – různé typy pevných vzorků zemin, sedimentů, kompostů, kalů, odpadů, půdy, stavebních konstrukcí","search_text":"Matryce stałe Oznaczanie suchej masy próbki stałej metodą wagową i wilgotności obliczeniowo z wartości zmierzonych Pevné matrice Stanovení sušiny pevného vzorku gravimetricky a vlhkosti výpočtem z naměřených hodnot SOP AL-45 (ČSN EN 15934) Matryce stale Oznaczanie suchej masy probki stalej metoda wagowa i wilgotnosci obliczeniowo z wartosci zmierzonych Pevne matrice Stanoveni susiny pevneho vzorku gravimetricky a vlhkosti vypoctem z namerenych hodnot SOP AL-45 (CSN EN 15934)","search_en":"Solid matrices Determination of dry matter of a solid sample by gravimetry and moisture by calculation from measured values SOP AL-45 (ČSN EN 15934)","search_zh":"固体基质 重量法测定固体样品干物质及由测量值计算水分 SOP AL-45 (ČSN EN 15934)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4758f3d4631b102fc003dc12","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"57","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie straty prażenia (substancji palnych) metodą wagową i pozostałości po prażeniu obliczeniowo z wartości zmierzonych, obliczeniowo stosunek C:N","methodology_en":"Determination of loss on ignition (combustible matter) by gravimetry and residue on ignition by calculation from measured values, C:N ratio by calculation","methodology_zh":"重量法测定灼烧损失（可燃物）及由测量值计算灼烧残渣，计算C:N比","methodology_cs":"Stanovení ztráty žíháním (spalitelných látek) gravimetricky a zbytku po žíhání výpočtem z naměřených hodnot, výpočtem poměr C:N","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie straty prażenia (substancji palnych) metodą wagową i pozostałości po prażeniu obliczeniowo z wartości zmierzonych, obliczeniowo stosunek C:N","reference":"SOP AL-46 (ČSN EN 15935)","norm_bases":["SOP AL-46","ČSN EN 15935"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Matryce stałe – różne rodzaje próbek stałych gruntów, osadów dennych, kompostów, osadów, odpadów, gleby, konstrukcji budowlanych | laboratoryjne oznaczenie N wykonuje zewnętrzny dostawca badania w zakresie swojej akredytacji","note_en":"Solid matrices – various types of solid samples of soils, sediments, composts, sludge, waste, soil, building structures | the laboratory determination of N is performed by an external test provider within the scope of its accreditation","note_zh":"固体基质–土、沉积物、堆肥、污泥、废物、土壤、建筑结构等各类固体样品 | 氮的实验室测定由外部检测提供方在其认可范围内进行","note_cs":"Pevné matrice – různé typy pevných vzorků zemin, sedimentů, kompostů, kalů, odpadů, půdy, stavebních konstrukcí | laboratorní stanovení N je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Matryce stałe Oznaczanie straty prażenia (substancji palnych) metodą wagową i pozostałości po prażeniu obliczeniowo z wartości zmierzonych, obliczeniowo stosunek C:N Pevné matrice Stanovení ztráty žíháním (spalitelných látek) gravimetricky a zbytku po žíhání výpočtem z naměřených hodnot, výpočtem poměr C:N SOP AL-46 (ČSN EN 15935) Matryce stale Oznaczanie straty prazenia (substancji palnych) metoda wagowa i pozostalosci po prazeniu obliczeniowo z wartosci zmierzonych, obliczeniowo stosunek C:N Pevne matrice Stanoveni ztraty zihanim (spalitelnych latek) gravimetricky a zbytku po zihani vypoctem z namerenych hodnot, vypoctem pomer C:N SOP AL-46 (CSN EN 15935)","search_en":"Solid matrices Determination of loss on ignition (combustible matter) by gravimetry and residue on ignition by calculation from measured values, C:N ratio by calculation SOP AL-46 (ČSN EN 15935)","search_zh":"固体基质 重量法测定灼烧损失（可燃物）及由测量值计算灼烧残渣，计算C:N比 SOP AL-46 (ČSN EN 15935)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"85ea19be1f2f762b3465a1b8","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"58","test_object":"Powietrze glebowe","test_object_en":"Soil air","test_object_zh":"土壤空气","test_object_cs":"Půdní vzduch","methodology":"Orientacyjne oznaczanie metanu i ditlenku węgla metodą IR oraz tlenku węgla, siarkowodoru i tlenu metodą elektrochemiczną analizatorem przenośnym","methodology_en":"Preliminary determination of methane and carbon dioxide by IR and of carbon monoxide, hydrogen sulphide and oxygen electrochemically with a mobile analyser","methodology_zh":"便携式分析仪初步测定甲烷和二氧化碳（红外法）及一氧化碳、硫化氢和氧气（电化学法）","methodology_cs":"Orientační stanovení methanu a oxidu uhličitého metodou IR a oxidu uhelnatého, sirovodíku a kyslíku elektrochemicky mobilním analyzátorem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Orientacyjne oznaczanie metanu i ditlenku węgla metodą IR oraz tlenku węgla, siarkowodoru i tlenu metodą elektrochemiczną analizatorem przenośnym","reference":"SOP AL-47 (manuál výrobce Hermann Sewerin)","norm_bases":["SOP AL-47","manuál výrobce Hermann Sewerin"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze glebowe Orientacyjne oznaczanie metanu i ditlenku węgla metodą IR oraz tlenku węgla, siarkowodoru i tlenu metodą elektrochemiczną analizatorem przenośnym Půdní vzduch Orientační stanovení methanu a oxidu uhličitého metodou IR a oxidu uhelnatého, sirovodíku a kyslíku elektrochemicky mobilním analyzátorem SOP AL-47 (manuál výrobce Hermann Sewerin) Powietrze glebowe Orientacyjne oznaczanie metanu i ditlenku wegla metoda IR oraz tlenku wegla, siarkowodoru i tlenu metoda elektrochemiczna analizatorem przenosnym Pudni vzduch Orientacni stanoveni methanu a oxidu uhliciteho metodou IR a oxidu uhelnateho, sirovodiku a kysliku elektrochemicky mobilnim analyzatorem SOP AL-47 (manual vyrobce Hermann Sewerin)","search_en":"Soil air Preliminary determination of methane and carbon dioxide by IR and of carbon monoxide, hydrogen sulphide and oxygen electrochemically with a mobile analyser SOP AL-47 (manuál výrobce Hermann Sewerin)","search_zh":"土壤空气 便携式分析仪初步测定甲烷和二氧化碳（红外法）及一氧化碳、硫化氢和氧气（电化学法） SOP AL-47 (manuál výrobce Hermann Sewerin)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"52ecd2adc942639a5012d01f","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"60","test_object":"Woda przeznaczona do spożycia i wody powierzchniowe","test_object_en":"Drinking and surface water","test_object_zh":"饮用水和地表水","test_object_cs":"Pitná a povrchová voda","methodology":"Oznaczanie chloru wolnego i ogólnego metodą kolorymetryczną – komercyjny zestaw analityczny HACH LANGE oraz chloru związanego obliczeniowo","methodology_en":"Determination of free and total chlorine by colorimetry - HACH LANGE commercial analytical set and of combined chlorine by calculation","methodology_zh":"游离氯和总氯测定（比色法）–HACH LANGE商品试剂盒及化合氯计算","methodology_cs":"Stanovení volného a celkového chloru kolorimetricky – analytická komerční souprava HACH LANGE a vázaného chloru dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chloru wolnego i ogólnego metodą kolorymetryczną – komercyjny zestaw analityczny HACH LANGE oraz chloru związanego obliczeniowo","reference":"SOP AL-49 (návod firmy HACH LANGE)","norm_bases":["SOP AL-49","návod firmy HACH LANGE"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda przeznaczona do spożycia i wody powierzchniowe Oznaczanie chloru wolnego i ogólnego metodą kolorymetryczną – komercyjny zestaw analityczny HACH LANGE oraz chloru związanego obliczeniowo Pitná a povrchová voda Stanovení volného a celkového chloru kolorimetricky – analytická komerční souprava HACH LANGE a vázaného chloru dopočtem SOP AL-49 (návod firmy HACH LANGE) Woda przeznaczona do spozycia i wody powierzchniowe Oznaczanie chloru wolnego i ogolnego metoda kolorymetryczna – komercyjny zestaw analityczny HACH LANGE oraz chloru zwiazanego obliczeniowo Pitna a povrchova voda Stanoveni volneho a celkoveho chloru kolorimetricky – analyticka komercni souprava HACH LANGE a vazaneho chloru dopoctem SOP AL-49 (navod firmy HACH LANGE)","search_en":"Drinking and surface water Determination of free and total chlorine by colorimetry - HACH LANGE commercial analytical set and of combined chlorine by calculation SOP AL-49 (návod firmy HACH LANGE)","search_zh":"饮用水和地表水 游离氯和总氯测定（比色法）–HACH LANGE商品试剂盒及化合氯计算 SOP AL-49 (návod firmy HACH LANGE)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1f0e3d5ae99ab78102b7e572","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"61","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie temperatury","methodology_en":"Determination of temperature","methodology_zh":"温度测定","methodology_cs":"Stanovení teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury","reference":"SOP AL-50 (ČSN 75 7342)","norm_bases":["SOP AL-50","ČSN 75 7342"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie temperatury Pitná, podzemní, povrchová a odpadní voda Stanovení teploty SOP AL-50 (ČSN 75 7342) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie temperatury Pitna, podzemni, povrchova a odpadni voda Stanoveni teploty SOP AL-50 (CSN 75 7342)","search_en":"Drinking, ground, surface and waste water Determination of temperature SOP AL-50 (ČSN 75 7342)","search_zh":"饮用水、地下水、地表水和废水 温度测定 SOP AL-50 (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e30a0ac1d31bdf85d2a961a0","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"62","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice","methodology":"Oznaczanie zdolności neutralizacji zasad (ZNK) metodą miareczkową i obliczanie wolnego ditlenku węgla","methodology_en":"Determination of base neutralizing capacity (BNC) by titration and calculation of free carbon dioxide","methodology_zh":"碱中和能力测定（滴定法）及游离二氧化碳计算","methodology_cs":"Stanovení zásadové neutralizační kapacity (ZNK) titračně a výpočet volného oxidu uhličitého","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zdolności neutralizacji zasad (ZNK) metodą miareczkową i obliczanie wolnego ditlenku węgla","reference":"SOP AL-51 (ČSN 75 7372; ČSN 75 7373)","norm_bases":["SOP AL-51","ČSN 75 7372","ČSN 75 7373"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej Oznaczanie zdolności neutralizacji zasad (ZNK) metodą miareczkową i obliczanie wolnego ditlenku węgla Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice Stanovení zásadové neutralizační kapacity (ZNK) titračně a výpočet volného oxidu uhličitého SOP AL-51 (ČSN 75 7372; ČSN 75 7373) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej Oznaczanie zdolnosci neutralizacji zasad (ZNK) metoda miareczkowa i obliczanie wolnego ditlenku wegla Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice Stanoveni zasadove neutralizacni kapacity (ZNK) titracne a vypocet volneho oxidu uhliciteho SOP AL-51 (CSN 75 7372; CSN 75 7373)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix Determination of base neutralizing capacity (BNC) by titration and calculation of free carbon dioxide SOP AL-51 (ČSN 75 7372; ČSN 75 7373)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液 碱中和能力测定（滴定法）及游离二氧化碳计算 SOP AL-51 (ČSN 75 7372; ČSN 75 7373)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ed9c47dd87b178ded250013c","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"63","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice","methodology":"Oznaczanie potencjału oksydacyjno-redukcyjnego (ORP) metodą elektrometryczną","methodology_en":"Determination of oxidation–reduction potential (ORP) electrometrically","methodology_zh":"氧化还原电位（ORP）测定（电测法）","methodology_cs":"Stanovení oxidačně – redukčního potenciálu (ORP) elektrometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie potencjału oksydacyjno-redukcyjnego (ORP) metodą elektrometryczną","reference":"SOP AL-52 (ČSN 75 7367)","norm_bases":["SOP AL-52","ČSN 75 7367"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej Oznaczanie potencjału oksydacyjno-redukcyjnego (ORP) metodą elektrometryczną Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice Stanovení oxidačně – redukčního potenciálu (ORP) elektrometricky SOP AL-52 (ČSN 75 7367) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej Oznaczanie potencjalu oksydacyjno-redukcyjnego (ORP) metoda elektrometryczna Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice Stanoveni oxidacne – redukcniho potencialu (ORP) elektrometricky SOP AL-52 (CSN 75 7367)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix Determination of oxidation–reduction potential (ORP) electrometrically SOP AL-52 (ČSN 75 7367)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液 氧化还原电位（ORP）测定（电测法） SOP AL-52 (ČSN 75 7367)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dd5ca8d233f31841edb920ac","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"64","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki","test_object_en":"Drinking, ground, surface and waste water","test_object_zh":"饮用水、地下水、地表水和废水","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda","methodology":"Oznaczanie mętności metodą nefelometryczną","methodology_en":"Determination of turbidity by nephelometry","methodology_zh":"浊度测定（散射比浊法）","methodology_cs":"Stanovení zákalu nefelometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mętności metodą nefelometryczną","reference":"SOP AL-53 (ČSN EN ISO 7027-1)","norm_bases":["SOP AL-53","ČSN EN ISO 7027-1"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki Oznaczanie mętności metodą nefelometryczną Pitná, podzemní, povrchová a odpadní voda Stanovení zákalu nefelometricky SOP AL-53 (ČSN EN ISO 7027-1) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki Oznaczanie metnosci metoda nefelometryczna Pitna, podzemni, povrchova a odpadni voda Stanoveni zakalu nefelometricky SOP AL-53 (CSN EN ISO 7027-1)","search_en":"Drinking, ground, surface and waste water Determination of turbidity by nephelometry SOP AL-53 (ČSN EN ISO 7027-1)","search_zh":"饮用水、地下水、地表水和废水 浊度测定（散射比浊法） SOP AL-53 (ČSN EN ISO 7027-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"978594cb49b6f583823144c0","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"65","test_object":"Woda przeznaczona do spożycia, wody podziemne i powierzchniowe","test_object_en":"Drinking, ground and surface water","test_object_zh":"饮用水、地下水和地表水","test_object_cs":"Pitná, podzemní a povrchová voda","methodology":"Oznaczanie barwy metodą fotometryczną","methodology_en":"Determination of colour by photometry","methodology_zh":"色度测定（光度法）","methodology_cs":"Stanovení barvy fotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie barwy metodą fotometryczną","reference":"SOP AL-54 (ČSN EN ISO 7887, metoda C)","norm_bases":["SOP AL-54","ČSN EN ISO 7887, metoda C"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Ground water – mineral, spa, mine water","note_zh":"地下水–矿泉水、温泉水、矿井水","note_cs":"Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne i powierzchniowe Oznaczanie barwy metodą fotometryczną Pitná, podzemní a povrchová voda Stanovení barvy fotometricky SOP AL-54 (ČSN EN ISO 7887, metoda C) Woda przeznaczona do spozycia, wody podziemne i powierzchniowe Oznaczanie barwy metoda fotometryczna Pitna, podzemni a povrchova voda Stanoveni barvy fotometricky SOP AL-54 (CSN EN ISO 7887, metoda C)","search_en":"Drinking, ground and surface water Determination of colour by photometry SOP AL-54 (ČSN EN ISO 7887, metoda C)","search_zh":"饮用水、地下水和地表水 色度测定（光度法） SOP AL-54 (ČSN EN ISO 7887, metoda C)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2a13ca5022da13773896d103","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"66","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok","methodology":"Oznaczanie fenoli jednowodorotlenowych metodą CFA","methodology_en":"Determination of phenol index by CFA","methodology_zh":"CFA法测定一元酚","methodology_cs":"Stanovení jednosytných fenolů metodou CFA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fenoli jednowodorotlenowych metodą CFA","reference":"SOP AL-55 (ČSN EN ISO 14402; návod firmy Skalar)","norm_bases":["SOP AL-55","ČSN EN ISO 14402","návod firmy Skalar"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny Oznaczanie fenoli jednowodorotlenowych metodą CFA Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok Stanovení jednosytných fenolů metodou CFA SOP AL-55 (ČSN EN ISO 14402; návod firmy Skalar) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny Oznaczanie fenoli jednowodorotlenowych metoda CFA Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok Stanoveni jednosytnych fenolu metodou CFA SOP AL-55 (CSN EN ISO 14402; navod firmy Skalar)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution Determination of phenol index by CFA SOP AL-55 (ČSN EN ISO 14402; návod firmy Skalar)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液 CFA法测定一元酚 SOP AL-55 (ČSN EN ISO 14402; návod firmy Skalar)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"29db3e42a2d6fca337111960","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"67","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok","methodology":"Oznaczanie jonów amonowych metodą CFA, azotu amonowego i wolnego amoniaku obliczeniowo z wartości zmierzonych","methodology_en":"Determination of ammonium by CFA, determination of ammonia nitrogen and free ammonia by calculation from measured values","methodology_zh":"CFA法测定铵离子，由测量值计算氨氮和游离氨","methodology_cs":"Stanovení amonných iontů metodou CFA, stanovení amoniakálního dusíku a volného amoniaku výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych metodą CFA, azotu amonowego i wolnego amoniaku obliczeniowo z wartości zmierzonych","reference":"SOP AL-56 (ČSN EN ISO 11732; návod firmy Skalar)","norm_bases":["SOP AL-56","ČSN EN ISO 11732","návod firmy Skalar"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane | Roztwór absorpcyjny – roztwór absorpcyjny z poboru emisji","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water | Absorption solution – absorption solution from emission sampling","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水 | 吸收液–排放采样吸收液","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní | Absorpční roztok – absorpční roztok z odběru emisí","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny Oznaczanie jonów amonowych metodą CFA, azotu amonowego i wolnego amoniaku obliczeniowo z wartości zmierzonych Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok Stanovení amonných iontů metodou CFA, stanovení amoniakálního dusíku a volného amoniaku výpočtem z naměřených hodnot SOP AL-56 (ČSN EN ISO 11732; návod firmy Skalar) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny, roztwor absorpcyjny Oznaczanie jonow amonowych metoda CFA, azotu amonowego i wolnego amoniaku obliczeniowo z wartosci zmierzonych Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok, absorpcni roztok Stanoveni amonnych iontu metodou CFA, stanoveni amoniakalniho dusiku a volneho amoniaku vypoctem z namerenych hodnot SOP AL-56 (CSN EN ISO 11732; navod firmy Skalar)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution Determination of ammonium by CFA, determination of ammonia nitrogen and free ammonia by calculation from measured values SOP AL-56 (ČSN EN ISO 11732; návod firmy Skalar)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液 CFA法测定铵离子，由测量值计算氨氮和游离氨 SOP AL-56 (ČSN EN ISO 11732; návod firmy Skalar)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"48194b4eb03603bd1c231a2c","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"68","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok","methodology":"Oznaczanie cyjanków ogólnych metodą CFA","methodology_en":"Determination of total cyanide by CFA","methodology_zh":"CFA法测定总氰化物","methodology_cs":"Stanovení veškerých kyanidů metodou CFA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cyjanków ogólnych metodą CFA","reference":"SOP AL-57 (ČSN EN ISO 14403-2; návod firmy Skalar)","norm_bases":["SOP AL-57","ČSN EN ISO 14403-2","návod firmy Skalar"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny Oznaczanie cyjanków ogólnych metodą CFA Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok Stanovení veškerých kyanidů metodou CFA SOP AL-57 (ČSN EN ISO 14403-2; návod firmy Skalar) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny Oznaczanie cyjankow ogolnych metoda CFA Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok Stanoveni veskerych kyanidu metodou CFA SOP AL-57 (CSN EN ISO 14403-2; navod firmy Skalar)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution Determination of total cyanide by CFA SOP AL-57 (ČSN EN ISO 14403-2; návod firmy Skalar)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液 CFA法测定总氰化物 SOP AL-57 (ČSN EN ISO 14403-2; návod firmy Skalar)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b8cfb50177d1259bab65d9ff","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"69","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok","methodology":"Oznaczanie azotynów i azotanów metodą CFA, azotu azotynowego i azotanowego obliczeniowo z wartości zmierzonych","methodology_en":"Determination of nitrite and nitrate by CFA, determination of nitrite and nitrate nitrogen by calculation from measured values","methodology_zh":"CFA法测定亚硝酸盐和硝酸盐，由测量值计算亚硝酸盐氮和硝酸盐氮","methodology_cs":"Stanovení dusitanů a dusičnanů metodou CFA, stanovení dusitanového a dusičnanového dusíku výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotynów i azotanów metodą CFA, azotu azotynowego i azotanowego obliczeniowo z wartości zmierzonych","reference":"SOP AL-59 (ČSN EN ISO 13395; návod firmy Skalar)","norm_bases":["SOP AL-59","ČSN EN ISO 13395","návod firmy Skalar"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane | Roztwór absorpcyjny – roztwór absorpcyjny z poboru emisji","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water | Absorption solution – absorption solution from emission sampling","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水 | 吸收液–排放采样吸收液","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní | Absorpční roztok – absorpční roztok z odběru emisí","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny, roztwór absorpcyjny Oznaczanie azotynów i azotanów metodą CFA, azotu azotynowego i azotanowego obliczeniowo z wartości zmierzonych Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok, absorpční roztok Stanovení dusitanů a dusičnanů metodou CFA, stanovení dusitanového a dusičnanového dusíku výpočtem z naměřených hodnot SOP AL-59 (ČSN EN ISO 13395; návod firmy Skalar) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny, roztwor absorpcyjny Oznaczanie azotynow i azotanow metoda CFA, azotu azotynowego i azotanowego obliczeniowo z wartosci zmierzonych Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok, absorpcni roztok Stanoveni dusitanu a dusicnanu metodou CFA, stanoveni dusitanoveho a dusicnanoveho dusiku vypoctem z namerenych hodnot SOP AL-59 (CSN EN ISO 13395; navod firmy Skalar)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution, absorption solution Determination of nitrite and nitrate by CFA, determination of nitrite and nitrate nitrogen by calculation from measured values SOP AL-59 (ČSN EN ISO 13395; návod firmy Skalar)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液、吸收液 CFA法测定亚硝酸盐和硝酸盐，由测量值计算亚硝酸盐氮和硝酸盐氮 SOP AL-59 (ČSN EN ISO 13395; návod firmy Skalar)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b592cd24c230f48e5f01b38f","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"70","test_object":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny","test_object_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution","test_object_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液","test_object_cs":"Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok","methodology":"Oznaczanie fosforanów metodą CFA, fosforu fosforanowego obliczeniowo z wartości zmierzonych","methodology_en":"Determination of phosphate by CFA, determination of phosphate phosphorus by calculation from measured values","methodology_zh":"CFA法测定磷酸盐，由测量值计算磷酸盐磷","methodology_cs":"Stanovení fosforečnanů metodou CFA, stanovení fosforečnanového fosforu výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforanów metodą CFA, fosforu fosforanowego obliczeniowo z wartości zmierzonych","reference":"SOP AL-60 (ČSN EN ISO 15681-2; návod firmy Skalar)","norm_bases":["SOP AL-60","ČSN EN ISO 15681-2","návod firmy Skalar"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Roztwór wodny – roztwór o określonym składzie lub roztwór chemikaliów w wodzie | Ścieki – z oczyszczalni, przemysłowe, technologiczne | Wody podziemne – mineralne, lecznicze, kopalniane","note_en":"Aqueous solution – solution of defined composition or solution of a chemical in water | Waste water – WWTP, industrial, process | Ground water – mineral, spa, mine water","note_zh":"水溶液–成分确定的溶液或化学品水溶液 | 废水–污水处理厂、工业、工艺废水 | 地下水–矿泉水、温泉水、矿井水","note_cs":"Vodný roztok – roztok definovaného složení, resp. roztok chemikálie ve vodě | Odpadní voda – ČOV, průmyslová, technologická | Podzemní – minerální, lázeňská, důlní","search_text":"Woda przeznaczona do spożycia, wody podziemne, powierzchniowe i ścieki, wyciąg z matrycy stałej, roztwór wodny Oznaczanie fosforanów metodą CFA, fosforu fosforanowego obliczeniowo z wartości zmierzonych Pitná, podzemní, povrchová a odpadní voda, výluh z pevné matrice, vodný roztok Stanovení fosforečnanů metodou CFA, stanovení fosforečnanového fosforu výpočtem z naměřených hodnot SOP AL-60 (ČSN EN ISO 15681-2; návod firmy Skalar) Woda przeznaczona do spozycia, wody podziemne, powierzchniowe i scieki, wyciag z matrycy stalej, roztwor wodny Oznaczanie fosforanow metoda CFA, fosforu fosforanowego obliczeniowo z wartosci zmierzonych Pitna, podzemni, povrchova a odpadni voda, vyluh z pevne matrice, vodny roztok Stanoveni fosforecnanu metodou CFA, stanoveni fosforecnanoveho fosforu vypoctem z namerenych hodnot SOP AL-60 (CSN EN ISO 15681-2; navod firmy Skalar)","search_en":"Drinking, ground, surface and waste water, leachate of solid matrix, aqueous solution Determination of phosphate by CFA, determination of phosphate phosphorus by calculation from measured values SOP AL-60 (ČSN EN ISO 15681-2; návod firmy Skalar)","search_zh":"饮用水、地下水、地表水和废水、固体基质浸出液、水溶液 CFA法测定磷酸盐，由测量值计算磷酸盐磷 SOP AL-60 (ČSN EN ISO 15681-2; návod firmy Skalar)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e764b9ba9be9f8e6bf78f0f2","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"1","test_object":"Woda przeznaczona do spożycia, surowa i ciepła","test_object_en":"Drinking, raw and hot water","test_object_zh":"饮用水、原水和热水","test_object_cs":"Pitná, surová a teplá voda","methodology":"Pobieranie próbek wody przeznaczonej do spożycia, surowej i ciepłej","methodology_en":"Sampling of drinking, raw and hot water","methodology_zh":"饮用水、原水和热水采样","methodology_cs":"Odběr vzorků pitné, surové a teplé vody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wody przeznaczonej do spożycia, surowej i ciepłej","reference":"SOP VS-101 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 19458; ČSN ISO 5667-21)","norm_bases":["SOP VS-101","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-5","ČSN EN ISO 19458","ČSN ISO 5667-21"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda przeznaczona do spożycia, surowa i ciepła Pobieranie próbek wody przeznaczonej do spożycia, surowej i ciepłej Pitná, surová a teplá voda Odběr vzorků pitné, surové a teplé vody SOP VS-101 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 19458; ČSN ISO 5667-21) Woda przeznaczona do spozycia, surowa i ciepla Pobieranie probek wody przeznaczonej do spozycia, surowej i cieplej Pitna, surova a tepla voda Odber vzorku pitne, surove a teple vody SOP VS-101 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-5; CSN EN ISO 19458; CSN ISO 5667-21)","search_en":"Drinking, raw and hot water Sampling of drinking, raw and hot water SOP VS-101 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 19458; ČSN ISO 5667-21)","search_zh":"饮用水、原水和热水 饮用水、原水和热水采样 SOP VS-101 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 19458; ČSN ISO 5667-21)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bd494dfbbf5f749b15e0208c","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"2","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní voda","methodology":"Pobieranie próbek ścieków (ręczne i automatycznymi próbnikami)","methodology_en":"Sampling of waste water (manual and with automatic samplers)","methodology_zh":"废水采样（手动和自动采样器）","methodology_cs":"Odběr vzorků odpadních vod (manuální odběr a odběr automatickými vzorkovači)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków (ręczne i automatycznymi próbnikami)","reference":"SOP VS-102 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN 75 7315)","norm_bases":["SOP VS-102","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN 75 7315"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków (ręczne i automatycznymi próbnikami) Odpadní voda Odběr vzorků odpadních vod (manuální odběr a odběr automatickými vzorkovači) SOP VS-102 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN 75 7315) Scieki Pobieranie probek sciekow (reczne i automatycznymi probnikami) Odpadni voda Odber vzorku odpadnich vod (manualni odber a odber automatickymi vzorkovaci) SOP VS-102 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN 75 7315)","search_en":"Waste water Sampling of waste water (manual and with automatic samplers) SOP VS-102 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN 75 7315)","search_zh":"废水 废水采样（手动和自动采样器） SOP VS-102 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN 75 7315)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4a2cb9ede6f3cc2c88e520e7","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"3","test_object":"Wody podziemne","test_object_en":"Ground water","test_object_zh":"地下水","test_object_cs":"Podzemní voda","methodology":"Pobieranie próbek wód podziemnych (statyczne i dynamiczne)","methodology_en":"Sampling of ground water (static and dynamic sampling)","methodology_zh":"地下水采样（静态和动态采样）","methodology_cs":"Odběr vzorků podzemních vod (statický a dynamický odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód podziemnych (statyczne i dynamiczne)","reference":"SOP VS-103 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 19458)","norm_bases":["SOP VS-103","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-11","ČSN EN ISO 19458"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody podziemne Pobieranie próbek wód podziemnych (statyczne i dynamiczne) Podzemní voda Odběr vzorků podzemních vod (statický a dynamický odběr) SOP VS-103 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 19458) Wody podziemne Pobieranie probek wod podziemnych (statyczne i dynamiczne) Podzemni voda Odber vzorku podzemnich vod (staticky a dynamicky odber) SOP VS-103 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-11; CSN EN ISO 19458)","search_en":"Ground water Sampling of ground water (static and dynamic sampling) SOP VS-103 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 19458)","search_zh":"地下水 地下水采样（静态和动态采样） SOP VS-103 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"afbfa56070f2ef778425086e","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"4","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchová voda","methodology":"Pobieranie próbek wód powierzchniowych (ręczne)","methodology_en":"Sampling of surface water (manual sampling)","methodology_zh":"地表水采样（手动）","methodology_cs":"Odběr vzorků povrchových vod (manuální odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód powierzchniowych (ręczne)","reference":"SOP VS-104 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 19458)","norm_bases":["SOP VS-104","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-4","ČSN EN ISO 5667-6","ČSN EN ISO 19458"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Pobieranie próbek wód powierzchniowych (ręczne) Povrchová voda Odběr vzorků povrchových vod (manuální odběr) SOP VS-104 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 19458) Wody powierzchniowe Pobieranie probek wod powierzchniowych (reczne) Povrchova voda Odber vzorku povrchovych vod (manualni odber) SOP VS-104 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-4; CSN EN ISO 5667-6; CSN EN ISO 19458)","search_en":"Surface water Sampling of surface water (manual sampling) SOP VS-104 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 19458)","search_zh":"地表水 地表水采样（手动） SOP VS-104 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"963bddfd42c675f1b547744d","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"5","test_object":"Grunt","test_object_en":"Soil","test_object_zh":"土","test_object_cs":"Zemina","methodology":"Pobieranie próbek gruntów","methodology_en":"Sampling of soils","methodology_zh":"土壤采样","methodology_cs":"Odběr vzorků zemin","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek gruntów","reference":"SOP VS-106 (ČSN 015111)","norm_bases":["SOP VS-106","ČSN 015111"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunt Pobieranie próbek gruntów Zemina Odběr vzorků zemin SOP VS-106 (ČSN 015111) Grunt Pobieranie probek gruntow Zemina Odber vzorku zemin SOP VS-106 (CSN 015111)","search_en":"Soil Sampling of soils SOP VS-106 (ČSN 015111)","search_zh":"土 土壤采样 SOP VS-106 (ČSN 015111)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"26fca0edd8bd4ea16deefc0a","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"6","test_object":"Osad denny, osad","test_object_en":"Bottom sediment, sludge","test_object_zh":"底部沉积物、污泥","test_object_cs":"Dnový sediment, kal","methodology":"Pobieranie próbek osadów dennych i osadów","methodology_en":"Sampling of bottom sediments and sludge","methodology_zh":"底部沉积物和污泥采样","methodology_cs":"Odběr vzorků dnových sedimentů a kalů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek osadów dennych i osadów","reference":"SOP VS-107 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-13)","norm_bases":["SOP VS-107","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-12","ČSN EN ISO 5667-13"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad denny, osad Pobieranie próbek osadów dennych i osadów Dnový sediment, kal Odběr vzorků dnových sedimentů a kalů SOP VS-107 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-13) Osad denny, osad Pobieranie probek osadow dennych i osadow Dnovy sediment, kal Odber vzorku dnovych sedimentu a kalu SOP VS-107 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-12; CSN EN ISO 5667-13)","search_en":"Bottom sediment, sludge Sampling of bottom sediments and sludge SOP VS-107 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-13)","search_zh":"底部沉积物、污泥 底部沉积物和污泥采样 SOP VS-107 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-13)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8524e598dd4f9817842bd1aa","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"7","test_object":"Odpady, materiały i konstrukcje budowlane","test_object_en":"Waste, building materials and structures","test_object_zh":"废物、建筑材料和结构","test_object_cs":"Odpady, stavební materiály a konstrukce","methodology":"Pobieranie próbek odpadów, materiałów i konstrukcji budowlanych","methodology_en":"Sampling of waste, building materials and structures","methodology_zh":"废物、建筑材料和结构采样","methodology_cs":"Odběr vzorků odpadů, stavebních materiálů a konstrukcí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek odpadów, materiałów i konstrukcji budowlanych","reference":"SOP VS-108 (ČSN EN 14899; Věstník MŽP, č. 4, duben 2008)","norm_bases":["SOP VS-108","ČSN EN 14899","Věstník MŽP, č. 4, duben 2008"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Odpady, materiały i konstrukcje budowlane Pobieranie próbek odpadów, materiałów i konstrukcji budowlanych Odpady, stavební materiály a konstrukce Odběr vzorků odpadů, stavebních materiálů a konstrukcí SOP VS-108 (ČSN EN 14899; Věstník MŽP, č. 4, duben 2008) Odpady, materialy i konstrukcje budowlane Pobieranie probek odpadow, materialow i konstrukcji budowlanych Odpady, stavebni materialy a konstrukce Odber vzorku odpadu, stavebnich materialu a konstrukci SOP VS-108 (CSN EN 14899; Vestnik MZP, c. 4, duben 2008)","search_en":"Waste, building materials and structures Sampling of waste, building materials and structures SOP VS-108 (ČSN EN 14899; Věstník MŽP, č. 4, duben 2008)","search_zh":"废物、建筑材料和结构 废物、建筑材料和结构采样 SOP VS-108 (ČSN EN 14899; Věstník MŽP, č. 4, duben 2008)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b0887a42dfc4b8d8c43be1cf","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"8","test_object":"Powietrze glebowe","test_object_en":"Soil air","test_object_zh":"土壤空气","test_object_cs":"Půdní vzduch","methodology":"Pobieranie próbek powietrza glebowego na sorbent stały","methodology_en":"Sampling of soil air onto a solid sorbent","methodology_zh":"固体吸附剂采集土壤空气样品","methodology_cs":"Odběr vzorků půdního vzduchu na pevný sorbent","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza glebowego na sorbent stały","reference":"SOP VS-109 (Věstník MŽP, č. 3, březen 2011; Věstník MŽP, č. 9, září 2005; Věstník MŽP, č. 2, únor 2007)","norm_bases":["SOP VS-109","Věstník MŽP, č. 3, březen 2011","Věstník MŽP, č. 9, září 2005","Věstník MŽP, č. 2, únor 2007"],"lab_section":"Laboratoria analityczne","lab_section_en":"Analytical laboratories","lab_section_zh":"分析实验室","lab_section_cs":"Analytické laboratoře","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze glebowe Pobieranie próbek powietrza glebowego na sorbent stały Půdní vzduch Odběr vzorků půdního vzduchu na pevný sorbent SOP VS-109 (Věstník MŽP, č. 3, březen 2011; Věstník MŽP, č. 9, září 2005; Věstník MŽP, č. 2, únor 2007) Powietrze glebowe Pobieranie probek powietrza glebowego na sorbent staly Pudni vzduch Odber vzorku pudniho vzduchu na pevny sorbent SOP VS-109 (Vestnik MZP, c. 3, brezen 2011; Vestnik MZP, c. 9, zari 2005; Vestnik MZP, c. 2, unor 2007)","search_en":"Soil air Sampling of soil air onto a solid sorbent SOP VS-109 (Věstník MŽP, č. 3, březen 2011; Věstník MŽP, č. 9, září 2005; Věstník MŽP, č. 2, únor 2007)","search_zh":"土壤空气 固体吸附剂采集土壤空气样品 SOP VS-109 (Věstník MŽP, č. 3, březen 2011; Věstník MŽP, č. 9, září 2005; Věstník MŽP, č. 2, únor 2007)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2f66000001803e4c7abef2dc","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"1","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie wilgotności","methodology_en":"Determination of water content","methodology_zh":"含水率测定","methodology_cs":"Stanovení vlhkosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności","reference":"ČSN EN ISO 17892-1","norm_bases":["ČSN EN ISO 17892-1"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie wilgotności Zeminy Stanovení vlhkosti ČSN EN ISO 17892-1 Grunty Oznaczanie wilgotnosci Zeminy Stanoveni vlhkosti CSN EN ISO 17892-1","search_en":"Soils Determination of water content ČSN EN ISO 17892-1","search_zh":"土 含水率测定 ČSN EN ISO 17892-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c8e8a135d28fd439bed9bbc9","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"2","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie gęstości objętościowej metodą pomiaru bezpośredniego","methodology_en":"Determination of bulk density by direct measurement","methodology_zh":"直接测量法测定密度","methodology_cs":"Stanovení objemové hmotnosti přímým měřením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej metodą pomiaru bezpośredniego","reference":"ČSN EN ISO 17892-2, čl. 4.1, 5.1, 6.1, 7","norm_bases":["ČSN EN ISO 17892-2, čl. 4.1, 5.1, 6.1, 7"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie gęstości objętościowej metodą pomiaru bezpośredniego Zeminy Stanovení objemové hmotnosti přímým měřením ČSN EN ISO 17892-2, čl. 4.1, 5.1, 6.1, 7 Grunty Oznaczanie gestosci objetosciowej metoda pomiaru bezposredniego Zeminy Stanoveni objemove hmotnosti primym merenim CSN EN ISO 17892-2, cl. 4.1, 5.1, 6.1, 7","search_en":"Soils Determination of bulk density by direct measurement ČSN EN ISO 17892-2, čl. 4.1, 5.1, 6.1, 7","search_zh":"土 直接测量法测定密度 ČSN EN ISO 17892-2, čl. 4.1, 5.1, 6.1, 7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a3754f2e5463655939dc1507","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"3","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie gęstości właściwej cząstek stałych","methodology_en":"Determination of particle density","methodology_zh":"土粒比重测定","methodology_cs":"Stanovení zdánlivé hustoty pevných částic","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości właściwej cząstek stałych","reference":"ČSN EN ISO 17892-3, mimo čl. 4.4, 5.2, 6.2","norm_bases":["ČSN EN ISO 17892-3, mimo čl. 4.4, 5.2, 6.2"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie gęstości właściwej cząstek stałych Zeminy Stanovení zdánlivé hustoty pevných částic ČSN EN ISO 17892-3, mimo čl. 4.4, 5.2, 6.2 Grunty Oznaczanie gestosci wlasciwej czastek stalych Zeminy Stanoveni zdanlive hustoty pevnych castic CSN EN ISO 17892-3, mimo cl. 4.4, 5.2, 6.2","search_en":"Soils Determination of particle density ČSN EN ISO 17892-3, mimo čl. 4.4, 5.2, 6.2","search_zh":"土 土粒比重测定 ČSN EN ISO 17892-3, mimo čl. 4.4, 5.2, 6.2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ad6b46112ee4d99b4668d7ca","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"4","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"颗粒级配测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN EN ISO 17892-4, mimo čl. 4.4, 5.4, 6.3","norm_bases":["ČSN EN ISO 17892-4, mimo čl. 4.4, 5.4, 6.3"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie uziarnienia Zeminy Stanovení zrnitosti ČSN EN ISO 17892-4, mimo čl. 4.4, 5.4, 6.3 Grunty Oznaczanie uziarnienia Zeminy Stanoveni zrnitosti CSN EN ISO 17892-4, mimo cl. 4.4, 5.4, 6.3","search_en":"Soils Determination of particle size distribution ČSN EN ISO 17892-4, mimo čl. 4.4, 5.4, 6.3","search_zh":"土 颗粒级配测定 ČSN EN ISO 17892-4, mimo čl. 4.4, 5.4, 6.3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8beb3cc283677d74f756b4df","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"5","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie granic konsystencji","methodology_en":"Determination of consistency limits","methodology_zh":"稠度界限测定","methodology_cs":"Stanovení konzistenčních mezí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie granic konsystencji","reference":"ČSN EN ISO 17892-12, mimo čl. 4.3, 5.4, 6.3","norm_bases":["ČSN EN ISO 17892-12, mimo čl. 4.3, 5.4, 6.3"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie granic konsystencji Zeminy Stanovení konzistenčních mezí ČSN EN ISO 17892-12, mimo čl. 4.3, 5.4, 6.3 Grunty Oznaczanie granic konsystencji Zeminy Stanoveni konzistencnich mezi CSN EN ISO 17892-12, mimo cl. 4.3, 5.4, 6.3","search_en":"Soils Determination of consistency limits ČSN EN ISO 17892-12, mimo čl. 4.3, 5.4, 6.3","search_zh":"土 稠度界限测定 ČSN EN ISO 17892-12, mimo čl. 4.3, 5.4, 6.3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"37430aa8c901422d49196944","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"6","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie węglanów","methodology_en":"Determination of carbonates","methodology_zh":"碳酸盐测定","methodology_cs":"Stanovení uhličitanů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglanów","reference":"ČSN 72 1022","norm_bases":["ČSN 72 1022"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie węglanów Zeminy Stanovení uhličitanů ČSN 72 1022 Grunty Oznaczanie weglanow Zeminy Stanoveni uhlicitanu CSN 72 1022","search_en":"Soils Determination of carbonates ČSN 72 1022","search_zh":"土 碳酸盐测定 ČSN 72 1022","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"88d8a4b2ff9d9afddf8422fa","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"7","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie straty prażenia","methodology_en":"Determination of loss on ignition","methodology_zh":"灼烧损失测定","methodology_cs":"Stanovení ztráty žíháním","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie straty prażenia","reference":"Metodiky ČGÚ 1987, kapitola 8 – pro zeminy ostatní","norm_bases":["Metodiky ČGÚ 1987, kapitola 8 – pro zeminy ostatní"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie straty prażenia Zeminy Stanovení ztráty žíháním Metodiky ČGÚ 1987, kapitola 8 – pro zeminy ostatní Grunty Oznaczanie straty prazenia Zeminy Stanoveni ztraty zihanim Metodiky CGU 1987, kapitola 8 – pro zeminy ostatni","search_en":"Soils Determination of loss on ignition Metodiky ČGÚ 1987, kapitola 8 – pro zeminy ostatní","search_zh":"土 灼烧损失测定 Metodiky ČGÚ 1987, kapitola 8 – pro zeminy ostatní","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"13d0916edcc7b5c2a3f3beef","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"8","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie zagęszczalności – badanie Proctora","methodology_en":"Determination of compactability – Proctor test","methodology_zh":"击实性测定–普氏击实试验","methodology_cs":"Stanovení zhutnitelnosti – Proctorova zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zagęszczalności – badanie Proctora","reference":"ČSN EN 13286-2, příloha NB","norm_bases":["ČSN EN 13286-2, příloha NB"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie zagęszczalności – badanie Proctora Zeminy Stanovení zhutnitelnosti – Proctorova zkouška ČSN EN 13286-2, příloha NB Grunty Oznaczanie zageszczalnosci – badanie Proctora Zeminy Stanoveni zhutnitelnosti – Proctorova zkouska CSN EN 13286-2, priloha NB","search_en":"Soils Determination of compactability – Proctor test ČSN EN 13286-2, příloha NB","search_zh":"土 击实性测定–普氏击实试验 ČSN EN 13286-2, příloha NB","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"175f1deba2768f2e7cc84dc4","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"9","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie wskaźnika nośności CBR, natychmiastowego wskaźnika nośności i pęcznienia liniowego","methodology_en":"Determination of California bearing ratio, immediate bearing index and linear swelling","methodology_zh":"加州承载比、即时承载指数和线性膨胀测定","methodology_cs":"Stanovení kalifornského poměru únosnosti, okamžitého indexu únosnosti a lineárního bobtnání","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wskaźnika nośności CBR, natychmiastowego wskaźnika nośności i pęcznienia liniowego","reference":"ČSN EN 13286-47","norm_bases":["ČSN EN 13286-47"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie wskaźnika nośności CBR, natychmiastowego wskaźnika nośności i pęcznienia liniowego Zeminy Stanovení kalifornského poměru únosnosti, okamžitého indexu únosnosti a lineárního bobtnání ČSN EN 13286-47 Grunty Oznaczanie wskaznika nosnosci CBR, natychmiastowego wskaznika nosnosci i pecznienia liniowego Zeminy Stanoveni kalifornskeho pomeru unosnosti, okamziteho indexu unosnosti a linearniho bobtnani CSN EN 13286-47","search_en":"Soils Determination of California bearing ratio, immediate bearing index and linear swelling ČSN EN 13286-47","search_zh":"土 加州承载比、即时承载指数和线性膨胀测定 ČSN EN 13286-47","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"93562d89e91119922e4c2711","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"10","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie ściśliwości w edometrze","methodology_en":"Determination of compressibility in an oedometer","methodology_zh":"固结仪压缩性测定","methodology_cs":"Stanovení stlačitelnosti v edometru","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ściśliwości w edometrze","reference":"ČSN EN ISO 17892-5","norm_bases":["ČSN EN ISO 17892-5"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie ściśliwości w edometrze Zeminy Stanovení stlačitelnosti v edometru ČSN EN ISO 17892-5 Grunty Oznaczanie scisliwosci w edometrze Zeminy Stanoveni stlacitelnosti v edometru CSN EN ISO 17892-5","search_en":"Soils Determination of compressibility in an oedometer ČSN EN ISO 17892-5","search_zh":"土 固结仪压缩性测定 ČSN EN ISO 17892-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"34826ff5b9d01552ea8d1cd1","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"11","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie pęcznienia w edometrze","methodology_en":"Determination of swelling in an oedometer","methodology_zh":"固结仪膨胀性测定","methodology_cs":"Stanovení bobtnavosti v edometru","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pęcznienia w edometrze","reference":"Metodiky ČGÚ 1987, kapitola 20, postup A","norm_bases":["Metodiky ČGÚ 1987, kapitola 20, postup A"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie pęcznienia w edometrze Zeminy Stanovení bobtnavosti v edometru Metodiky ČGÚ 1987, kapitola 20, postup A Grunty Oznaczanie pecznienia w edometrze Zeminy Stanoveni bobtnavosti v edometru Metodiky CGU 1987, kapitola 20, postup A","search_en":"Soils Determination of swelling in an oedometer Metodiky ČGÚ 1987, kapitola 20, postup A","search_zh":"土 固结仪膨胀性测定 Metodiky ČGÚ 1987, kapitola 20, postup A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":82,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"df24721c58ebffac6cd89f64","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"12","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Badanie wytrzymałości na ściskanie jednoosiowe","methodology_en":"Unconfined compression test","methodology_zh":"无侧限抗压强度试验","methodology_cs":"Zkouška pevnosti v prostém tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie wytrzymałości na ściskanie jednoosiowe","reference":"ČSN EN ISO 17892-7","norm_bases":["ČSN EN ISO 17892-7"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Badanie wytrzymałości na ściskanie jednoosiowe Zeminy Zkouška pevnosti v prostém tlaku ČSN EN ISO 17892-7 Grunty Badanie wytrzymalosci na sciskanie jednoosiowe Zeminy Zkouska pevnosti v prostem tlaku CSN EN ISO 17892-7","search_en":"Soils Unconfined compression test ČSN EN ISO 17892-7","search_zh":"土 无侧限抗压强度试验 ČSN EN ISO 17892-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":83,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"24e0d94082007e818e529e3e","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"13","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie wytrzymałości w badaniu trójosiowym bez konsolidacji i bez drenażu","methodology_en":"Unconsolidated undrained triaxial compression test","methodology_zh":"不固结不排水三轴强度试验","methodology_cs":"Stanovení pevnosti nekonsolidovanou neodvodněnou triaxiální zkouškou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości w badaniu trójosiowym bez konsolidacji i bez drenażu","reference":"ČSN EN ISO 17892-8","norm_bases":["ČSN EN ISO 17892-8"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie wytrzymałości w badaniu trójosiowym bez konsolidacji i bez drenażu Zeminy Stanovení pevnosti nekonsolidovanou neodvodněnou triaxiální zkouškou ČSN EN ISO 17892-8 Grunty Oznaczanie wytrzymalosci w badaniu trojosiowym bez konsolidacji i bez drenazu Zeminy Stanoveni pevnosti nekonsolidovanou neodvodnenou triaxialni zkouskou CSN EN ISO 17892-8","search_en":"Soils Unconsolidated undrained triaxial compression test ČSN EN ISO 17892-8","search_zh":"土 不固结不排水三轴强度试验 ČSN EN ISO 17892-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":84,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5379923765e1f344f58469ca","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"14","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Badanie ścinania w aparacie skrzynkowym","methodology_en":"Direct shear test","methodology_zh":"直剪试验","methodology_cs":"Krabicová smyková zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie ścinania w aparacie skrzynkowym","reference":"ČSN EN ISO 17892-10","norm_bases":["ČSN EN ISO 17892-10"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Badanie ścinania w aparacie skrzynkowym Zeminy Krabicová smyková zkouška ČSN EN ISO 17892-10 Grunty Badanie scinania w aparacie skrzynkowym Zeminy Krabicova smykova zkouska CSN EN ISO 17892-10","search_en":"Soils Direct shear test ČSN EN ISO 17892-10","search_zh":"土 直剪试验 ČSN EN ISO 17892-10","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":85,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ea4931ea5f1587b3ccc7926c","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"15","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie gęstości objętościowej","methodology_en":"Determination of bulk density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej","reference":"ČSN 72 1010, metoda D1","norm_bases":["ČSN 72 1010, metoda D1"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie gęstości objętościowej Zeminy Stanovení objemové hmotnosti ČSN 72 1010, metoda D1 Grunty Oznaczanie gestosci objetosciowej Zeminy Stanoveni objemove hmotnosti CSN 72 1010, metoda D1","search_en":"Soils Determination of bulk density ČSN 72 1010, metoda D1","search_zh":"土 密度测定 ČSN 72 1010, metoda D1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":86,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dfcdde6cfdede38fbb856fea","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"16","test_object":"Grunty i materiały sypkie","test_object_en":"Soils and granular materials","test_object_zh":"土和散粒材料","test_object_cs":"Zeminy a sypaniny","methodology":"Statyczna próba obciążeniowa","methodology_en":"Static plate load test","methodology_zh":"静载试验","methodology_cs":"Statická zatěžovací zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Statyczna próba obciążeniowa","reference":"ČSN 72 1006, příloha A, B, D","norm_bases":["ČSN 72 1006, příloha A, B, D"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty i materiały sypkie Statyczna próba obciążeniowa Zeminy a sypaniny Statická zatěžovací zkouška ČSN 72 1006, příloha A, B, D Grunty i materialy sypkie Statyczna proba obciazeniowa Zeminy a sypaniny Staticka zatezovaci zkouska CSN 72 1006, priloha A, B, D","search_en":"Soils and granular materials Static plate load test ČSN 72 1006, příloha A, B, D","search_zh":"土和散粒材料 静载试验 ČSN 72 1006, příloha A, B, D","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":87,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ef5e3b9bb88b5f097ea662db","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"17","test_object":"Nawierzchnie i podłoże","test_object_en":"Pavements and subgrade","test_object_zh":"路面和路基","test_object_cs":"Vozovky a podloží","methodology":"Udarowa próba obciążeniowa","methodology_en":"Dynamic plate load test","methodology_zh":"冲击加载试验","methodology_cs":"Rázová zatěžovací zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Udarowa próba obciążeniowa","reference":"ČSN 73 6192, skupina C","norm_bases":["ČSN 73 6192, skupina C"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nawierzchnie i podłoże Udarowa próba obciążeniowa Vozovky a podloží Rázová zatěžovací zkouška ČSN 73 6192, skupina C Nawierzchnie i podloze Udarowa proba obciazeniowa Vozovky a podlozi Razova zatezovaci zkouska CSN 73 6192, skupina C","search_en":"Pavements and subgrade Dynamic plate load test ČSN 73 6192, skupina C","search_zh":"路面和路基 冲击加载试验 ČSN 73 6192, skupina C","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":88,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0ae7ee8d5a8ab0483dcfae65","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"18","test_object":"Warstwy konstrukcyjne nawierzchni","test_object_en":"Pavement structural layers","test_object_zh":"路面结构层","test_object_cs":"Konstrukční vrstvy vozovky","methodology":"Pomiar nierówności nawierzchni łatą","methodology_en":"Measurement of road surface unevenness with a straightedge","methodology_zh":"直尺测量路面平整度","methodology_cs":"Měření nerovností povrchu vozovek latí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar nierówności nawierzchni łatą","reference":"ČSN 73 6175, kapitola 8","norm_bases":["ČSN 73 6175, kapitola 8"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwy konstrukcyjne nawierzchni Pomiar nierówności nawierzchni łatą Konstrukční vrstvy vozovky Měření nerovností povrchu vozovek latí ČSN 73 6175, kapitola 8 Warstwy konstrukcyjne nawierzchni Pomiar nierownosci nawierzchni lata Konstrukcni vrstvy vozovky Mereni nerovnosti povrchu vozovek lati CSN 73 6175, kapitola 8","search_en":"Pavement structural layers Measurement of road surface unevenness with a straightedge ČSN 73 6175, kapitola 8","search_zh":"路面结构层 直尺测量路面平整度 ČSN 73 6175, kapitola 8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":89,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a0194e6997ee06ce81fca233","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"19","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie zawartości wody przez suszenie w suszarce","methodology_en":"Determination of water content by drying in a ventilated oven","methodology_zh":"烘箱干燥法测定含水量","methodology_cs":"Stanovení vlhkosti sušením v sušárně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wody przez suszenie w suszarce","reference":"ČSN EN 1097-5","norm_bases":["ČSN EN 1097-5"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie zawartości wody przez suszenie w suszarce Kamenivo Stanovení vlhkosti sušením v sušárně ČSN EN 1097-5 Kruszywo Oznaczanie zawartosci wody przez suszenie w suszarce Kamenivo Stanoveni vlhkosti susenim v susarne CSN EN 1097-5","search_en":"Aggregates Determination of water content by drying in a ventilated oven ČSN EN 1097-5","search_zh":"集料 烘箱干燥法测定含水量 ČSN EN 1097-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":90,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f981609b2db4da3b537a78e4","lab_id":"69ad52a4de79e566650fd334","country":"CZ","accr_number":"1271","accr_body":"ČIA","row_label":"20","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie składu ziarnowego – analiza sitowa","methodology_en":"Determination of particle size distribution – sieving method","methodology_zh":"颗粒级配测定–筛分法","methodology_cs":"Stanovení zrnitosti – sítový rozbor","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie składu ziarnowego – analiza sitowa","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":"Laboratoria mechaniki gruntów","lab_section_en":"Soil mechanics laboratories","lab_section_zh":"土力学实验室","lab_section_cs":"Laboratoře mechaniky zemin","lab_address":"Šmahova 1244/112, Slatina, 627 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie składu ziarnowego – analiza sitowa Kamenivo Stanovení zrnitosti – sítový rozbor ČSN EN 933-1 Kruszywo Oznaczanie skladu ziarnowego – analiza sitowa Kamenivo Stanoveni zrnitosti – sitovy rozbor CSN EN 933-1","search_en":"Aggregates Determination of particle size distribution – sieving method ČSN EN 933-1","search_zh":"集料 颗粒级配测定–筛分法 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":91,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}