{"lab":{"_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","address":"Víta Nejedlého 951/8, Slezské Předměstí, 500 03 Hradec Králové","categories":["water","environment","microbiology","food"],"city":"Hradec Králové","imported_at":"2026-03-08T10:42:44.590Z","methods_count":133,"name":"Povodí Labe, státní podnik","parse_status":"parsed","parse_version":5,"pdf_files":["1264_34_2026_CS.pdf","1264_34_2026_EN.pdf"],"scope_summary":"Analizy chemiczne, mikrobiologiczne, hydrobiologiczne, radiochemiczne i ekotoksykologiczne (wody, grunty, osady denne, wyciągi, materiał biologiczny) oraz pobieranie próbek, w zakresie określonym w załączniku do świadectwa.","search_text":"povodí labe, státní podnik víta nejedlého 951/8, slezské předměstí, 500 03 hradec králové 1264","status":"active","updated_at":"2026-03-08T14:52:09.795Z","valid_from":"","valid_until":"05-05-2028","website":"www.pla.cz","location":{"type":"Point","coordinates":[15.8327,50.2093]},"map_coord":[50.21136,15.85122],"map_geo":"nominatim-street","certificate_date":"15.01.2026","certificate_no":"34/2026","certificate_replaces":"2/2025 z 06.01.2025","en_official":false,"fields_of_testing":[{"codes":"","pl":"Analizy chemiczne, mikrobiologiczne, hydrobiologiczne, radiochemiczne i ekotoksykologiczne (wody, grunty, osady denne, wyciągi, materiał biologiczny) oraz pobieranie próbek, w zakresie określonym w załączniku do świadectwa.","en":"Chemical, microbiological, hydrobiological, radiochemical and ecotoxicological analyses (water, earths, sediments, leachates, biological material) and sampling, to the extent specified in the appendix to this certificate.","zh":"化学、微生物、水生生物、放射化学和生态毒理学分析（水、土、沉积物、浸出液、生物材料）及采样，范围见本证书附件。","cs":"Chemické, mikrobiologické, hydrobiologické, radiochemické a ekotoxikologické analýzy (vody, zeminy, sedimenty, výluhy, biologický materiál) a vzorkování, vymezené přílohou tohoto osvědčení."}],"flexible_scope":true,"flexible_scope_url":"https://www.pla.cz/planet/webportal/internet/cs/obsah/informace-pro-zakazniky_5890.html#obsah","has_en":true,"has_zh":true,"lab_division":"wydział laboratoriów gospodarki wodnej, laboratorium Hradec Králové","lab_division_cs":"odbor vodohospodářských laboratoří, laboratoř Hradec Králové","lab_division_en":"Department of Water Management Laboratories, Hradec Králové laboratory","lab_division_zh":"水务实验室处，赫拉德茨-克拉洛韦实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"FTIR","pl":"spektrometria w podczerwieni z transformacją Fouriera","en":"Fourier-transform infrared spectrometry","zh":"傅里叶变换红外光谱法","cs":"infračervená spektrometrie s Fourierovou transformací"},{"abbr":"AES","pl":"atomowa spektrometria emisyjna","en":"atomic emission spectrometry","zh":"原子发射光谱法","cs":"atomová emisní spektrometrie"},{"abbr":"ICP/OES","pl":"optyczna spektrometria emisyjna z plazmą wzbudzoną indukcyjnie","en":"inductively coupled plasma optical emission spectrometry","zh":"电感耦合等离子体发射光谱法","cs":"optická emisní spektrometrie s indukčně vázaným plazmatem"},{"abbr":"ICP/MS","pl":"spektrometria mas z plazmą wzbudzoną indukcyjnie","en":"inductively coupled plasma mass spectrometry","zh":"电感耦合等离子体质谱法","cs":"hmotnostní spektrometrie s indukčně vázaným plazmatem"},{"abbr":"GC/MSD","pl":"chromatografia gazowa z detekcją masowo-selektywną","en":"gas chromatography with mass selective detection","zh":"气相色谱-质量选择检测","cs":"plynová chromatografie s hmotnostně selektivní detekcí"},{"abbr":"ECD","pl":"detektor wychwytu elektronów","en":"electron capture detector","zh":"电子捕获检测器","cs":"detektor elektronového záchytu"},{"abbr":"HPLC/FD","pl":"wysokosprawna chromatografia cieczowa z detekcją fluorymetryczną","en":"high-performance liquid chromatography with fluorescence detection","zh":"高效液相色谱-荧光检测","cs":"vysokoúčinná kapalinová chromatografie s fluorimetrickou detekcí"},{"abbr":"GC/NPD","pl":"chromatografia gazowa z detektorem azotowo-fosforowym","en":"gas chromatography with a nitrogen-phosphorus detector","zh":"气相色谱-氮磷检测器","cs":"plynová chromatografie s dusíko-fosforovým detektorem"},{"abbr":"GC/FID","pl":"chromatografia gazowa z detektorem płomieniowo-jonizacyjnym","en":"gas chromatography with a flame ionisation detector","zh":"气相色谱-火焰离子化检测器","cs":"plynová chromatografie s plamenovým ionizačním detektorem"},{"abbr":"LC/MS/MS","pl":"chromatografia cieczowa z tandemową detekcją masowo-selektywną","en":"liquid chromatography with tandem mass selective detection","zh":"液相色谱-串联质谱检测","cs":"kapalinová chromatografie s tandemovou hmotnostně selektivní detekcí"},{"abbr":"GC/MS/MS","pl":"chromatografia gazowa z tandemową detekcją masowo-selektywną","en":"gas chromatography with tandem mass selective detection","zh":"气相色谱-串联质谱检测","cs":"plynová chromatografie s tandemovou hmotnostně selektivní detekcí"},{"abbr":"GC/EI-MSD","pl":"chromatografia gazowa z detekcją masowo-selektywną i jonizacją elektronami","en":"gas chromatography with mass selective detection and electron ionisation","zh":"气相色谱-电子电离质量选择检测","cs":"plynová chromatografie s hmotnostně selektivní detekcí a elektronovou ionizací"},{"abbr":"GC/NCI-MSD","pl":"chromatografia gazowa z detekcją masowo-selektywną i ujemną jonizacją chemiczną","en":"gas chromatography with mass selective detection and negative chemical ionisation","zh":"气相色谱-负化学电离质量选择检测","cs":"plynová chromatografie s hmotnostně selektivní detekcí a negativní chemickou ionizací"}],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników badań.","en":"The laboratory provides opinions and interpretations of test results.","zh":"实验室提供检测结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků zkoušek."},{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The laboratory is competent to perform sampling independently.","zh":"实验室有能力独立进行采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."}],"source_lang":"cs","source_pdf_sha256":"7a89920d181c381faace767b46ba6432a871202c50327e01511c2fbb51813072","source_pdf_url":"https://www.cai.cz/OA/pdf/34_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/34_2026_EN.pdf"},"methods":[{"_id":"310bda79ccf573a3afc19792","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"1","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie anionów metodą izotachoforezy kapilarnej (ITP)","methodology_en":"Determination of anions by capillary isotachophoresis (ITP)","methodology_zh":"毛细管等速电泳法（ITP）测定阴离子","methodology_cs":"Stanovení aniontů kapilární izotachoforézou (ITP)","parameters":[{"name":"Siarczany","range":""},{"name":"fluorki","range":""}],"parameters_en":[{"name":"Sulphates","range":""},{"name":"fluorides","range":""}],"parameters_zh":[{"name":"硫酸盐","range":""},{"name":"氟化物","range":""}],"parameters_cs":[{"name":"Sírany","range":""},{"name":"fluoridy","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie anionów metodą izotachoforezy kapilarnej (ITP)\nZakres:\nSiarczany\nfluorki","reference":"AA02A (STN 75 7430)","norm_bases":["AA02A","STN 75 7430"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie anionów metodą izotachoforezy kapilarnej (ITP) Siarczany  fluorki  Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení aniontů kapilární izotachoforézou (ITP) Sírany  fluoridy  AA02A (STN 75 7430) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie anionow metoda izotachoforezy kapilarnej (ITP) Siarczany  fluorki  Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni aniontu kapilarni izotachoforezou (ITP) Sirany  fluoridy  AA02A (STN 75 7430)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of anions by capillary isotachophoresis (ITP) Sulphates  fluorides  AA02A (STN 75 7430)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 毛细管等速电泳法（ITP）测定阴离子 硫酸盐  氟化物  AA02A (STN 75 7430)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"54ef4dfd938d5e83b477289e","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"2","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie krzemianów metodą spektrofotometryczną","methodology_en":"Determination of silicates by spectrophotometry","methodology_zh":"分光光度法测定硅酸盐","methodology_cs":"Stanovení křemičitanů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie krzemianów metodą spektrofotometryczną","reference":"AA09A (ČSN 75 7481)","norm_bases":["AA09A","ČSN 75 7481"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie krzemianów metodą spektrofotometryczną Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení křemičitanů spektrofotometricky AA09A (ČSN 75 7481) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie krzemianow metoda spektrofotometryczna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni kremicitanu spektrofotometricky AA09A (CSN 75 7481)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of silicates by spectrophotometry AA09A (ČSN 75 7481)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 分光光度法测定硅酸盐 AA09A (ČSN 75 7481)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3a98df636a52b4560f03725d","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"3","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach, wody technologiczne i wyciągi","test_object_en":"Drinking, surface, ground and waste water, bathing water, process water and leachates","test_object_zh":"饮用水、地表水、地下水、废水、游泳/浴用水、工艺用水和浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní, vody ke koupání, vody technologické a výluhy","methodology":"Oznaczanie jonów amonowych metodą analizy przepływowej (CFA)","methodology_en":"Determination of ammonium ions by flow analysis (CFA)","methodology_zh":"流动分析法（CFA）测定铵离子","methodology_cs":"Stanovení amonných iontů průtokovou analýzou (CFA)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych metodą analizy przepływowej (CFA)","reference":"AA12A (ČSN EN ISO 11732)","norm_bases":["AA12A","ČSN EN ISO 11732"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach, wody technologiczne i wyciągi Oznaczanie jonów amonowych metodą analizy przepływowej (CFA) Vody pitné, povrchové, podzemní, odpadní, vody ke koupání, vody technologické a výluhy Stanovení amonných iontů průtokovou analýzou (CFA) AA12A (ČSN EN ISO 11732) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wody w kapieliskach, wody technologiczne i wyciagi Oznaczanie jonow amonowych metoda analizy przeplywowej (CFA) Vody pitne, povrchove, podzemni, odpadni, vody ke koupani, vody technologicke a vyluhy Stanoveni amonnych iontu prutokovou analyzou (CFA) AA12A (CSN EN ISO 11732)","search_en":"Drinking, surface, ground and waste water, bathing water, process water and leachates Determination of ammonium ions by flow analysis (CFA) AA12A (ČSN EN ISO 11732)","search_zh":"饮用水、地表水、地下水、废水、游泳/浴用水、工艺用水和浸出液 流动分析法（CFA）测定铵离子 AA12A (ČSN EN ISO 11732)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"86a28dbaf2f20ec69dd40bd0","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"4","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie fosforanów i fosforu ogólnego metodą analizy przepływowej (CFA)","methodology_en":"Determination of phosphates and total phosphorus by flow analysis (CFA)","methodology_zh":"流动分析法（CFA）测定磷酸盐和总磷","methodology_cs":"Stanovení fosforečnanů a celkového fosforu průtokovou analýzou (CFA)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforanów i fosforu ogólnego metodą analizy przepływowej (CFA)","reference":"AA13A (ČSN EN ISO 6878; ČSN EN ISO 15681-2)","norm_bases":["AA13A","ČSN EN ISO 6878","ČSN EN ISO 15681-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie fosforanów i fosforu ogólnego metodą analizy przepływowej (CFA) Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení fosforečnanů a celkového fosforu průtokovou analýzou (CFA) AA13A (ČSN EN ISO 6878; ČSN EN ISO 15681-2) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie fosforanow i fosforu ogolnego metoda analizy przeplywowej (CFA) Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni fosforecnanu a celkoveho fosforu prutokovou analyzou (CFA) AA13A (CSN EN ISO 6878; CSN EN ISO 15681-2)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of phosphates and total phosphorus by flow analysis (CFA) AA13A (ČSN EN ISO 6878; ČSN EN ISO 15681-2)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 流动分析法（CFA）测定磷酸盐和总磷 AA13A (ČSN EN ISO 6878; ČSN EN ISO 15681-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a81faede5cd5f7975a77a04c","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"5","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach, wody technologiczne i wyciągi","test_object_en":"Drinking, surface, ground and waste water, bathing water, process water and leachates","test_object_zh":"饮用水、地表水、地下水、废水、游泳/浴用水、工艺用水和浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní, vody ke koupání, vody technologické a výluhy","methodology":"Oznaczanie azotynów, azotanów i azotu ogólnego metodą analizy przepływowej (CFA) oraz obliczenie azotu nieorganicznego i organicznego z wartości zmierzonych","methodology_en":"Determination of nitrites, nitrates and total nitrogen by flow analysis (CFA) and calculation of inorganic and organic nitrogen from measured values","methodology_zh":"流动分析法（CFA）测定亚硝酸盐、硝酸盐和总氮并由测量值计算无机氮和有机氮","methodology_cs":"Stanovení dusitanů, dusičnanů a celkového dusíku průtokovou analýzou (CFA) a výpočet anorganického a organického dusíku z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotynów, azotanów i azotu ogólnego metodą analizy przepływowej (CFA) oraz obliczenie azotu nieorganicznego i organicznego z wartości zmierzonych","reference":"AA14A (ČSN ISO 29441; ČSN EN ISO 11905-1; ČSN EN ISO 13395)","norm_bases":["AA14A","ČSN ISO 29441","ČSN EN ISO 11905-1","ČSN EN ISO 13395"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach, wody technologiczne i wyciągi Oznaczanie azotynów, azotanów i azotu ogólnego metodą analizy przepływowej (CFA) oraz obliczenie azotu nieorganicznego i organicznego z wartości zmierzonych Vody pitné, povrchové, podzemní, odpadní, vody ke koupání, vody technologické a výluhy Stanovení dusitanů, dusičnanů a celkového dusíku průtokovou analýzou (CFA) a výpočet anorganického a organického dusíku z naměřených hodnot AA14A (ČSN ISO 29441; ČSN EN ISO 11905-1; ČSN EN ISO 13395) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wody w kapieliskach, wody technologiczne i wyciagi Oznaczanie azotynow, azotanow i azotu ogolnego metoda analizy przeplywowej (CFA) oraz obliczenie azotu nieorganicznego i organicznego z wartosci zmierzonych Vody pitne, povrchove, podzemni, odpadni, vody ke koupani, vody technologicke a vyluhy Stanoveni dusitanu, dusicnanu a celkoveho dusiku prutokovou analyzou (CFA) a vypocet anorganickeho a organickeho dusiku z namerenych hodnot AA14A (CSN ISO 29441; CSN EN ISO 11905-1; CSN EN ISO 13395)","search_en":"Drinking, surface, ground and waste water, bathing water, process water and leachates Determination of nitrites, nitrates and total nitrogen by flow analysis (CFA) and calculation of inorganic and organic nitrogen from measured values AA14A (ČSN ISO 29441; ČSN EN ISO 11905-1; ČSN EN ISO 13395)","search_zh":"饮用水、地表水、地下水、废水、游泳/浴用水、工艺用水和浸出液 流动分析法（CFA）测定亚硝酸盐、硝酸盐和总氮并由测量值计算无机氮和有机氮 AA14A (ČSN ISO 29441; ČSN EN ISO 11905-1; ČSN EN ISO 13395)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"951ecb154ac61c07f266885c","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"6","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie chlorków metodą analizy przepływowej (CFA)","methodology_en":"Determination of chlorides by flow analysis (CFA)","methodology_zh":"流动分析法（CFA）测定氯化物","methodology_cs":"Stanovení chloridů průtokovou analýzou (CFA)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków metodą analizy przepływowej (CFA)","reference":"AA16A (ČSN EN ISO 15682)","norm_bases":["AA16A","ČSN EN ISO 15682"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie chlorków metodą analizy przepływowej (CFA) Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení chloridů průtokovou analýzou (CFA) AA16A (ČSN EN ISO 15682) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie chlorkow metoda analizy przeplywowej (CFA) Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni chloridu prutokovou analyzou (CFA) AA16A (CSN EN ISO 15682)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of chlorides by flow analysis (CFA) AA16A (ČSN EN ISO 15682)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 流动分析法（CFA）测定氯化物 AA16A (ČSN EN ISO 15682)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1a97f46b0de3f648ef468fa4","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"7","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie siarczków metodą spektrofotometryczną","methodology_en":"Determination of sulphides by spectrophotometry","methodology_zh":"分光光度法测定硫化物","methodology_cs":"Stanovení sulfidů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie siarczków metodą spektrofotometryczną","reference":"AA18A (ČSN ISO 10530)","norm_bases":["AA18A","ČSN ISO 10530"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie siarczków metodą spektrofotometryczną Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení sulfidů spektrofotometricky AA18A (ČSN ISO 10530) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie siarczkow metoda spektrofotometryczna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni sulfidu spektrofotometricky AA18A (CSN ISO 10530)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of sulphides by spectrophotometry AA18A (ČSN ISO 10530)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 分光光度法测定硫化物 AA18A (ČSN ISO 10530)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7c5deff4a094de492b3ea811","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"8","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach i wody technologiczne","test_object_en":"Drinking, surface, ground and waste water, bathing water and process water","test_object_zh":"饮用水、地表水、地下水、废水、游泳/浴用水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní, vody ke koupání a vody technologické","methodology":"Oznaczanie chloru wolnego i całkowitego metodą spektrofotometryczną z użyciem komercyjnego zestawu analitycznego","methodology_en":"Determination of free and total chlorine by spectrophotometry using a commercial analytical kit","methodology_zh":"商品分析试剂盒分光光度法测定游离氯和总氯","methodology_cs":"Stanovení volného a celkového chlóru spektrofotometricky pomocí analytické komerční soupravy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chloru wolnego i całkowitego metodą spektrofotometryczną z użyciem komercyjnego zestawu analitycznego","reference":"AA19A (ČSN ISO 7393-2)","norm_bases":["AA19A","ČSN ISO 7393-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach i wody technologiczne Oznaczanie chloru wolnego i całkowitego metodą spektrofotometryczną z użyciem komercyjnego zestawu analitycznego Vody pitné, povrchové, podzemní, odpadní, vody ke koupání a vody technologické Stanovení volného a celkového chlóru spektrofotometricky pomocí analytické komerční soupravy AA19A (ČSN ISO 7393-2) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wody w kapieliskach i wody technologiczne Oznaczanie chloru wolnego i calkowitego metoda spektrofotometryczna z uzyciem komercyjnego zestawu analitycznego Vody pitne, povrchove, podzemni, odpadni, vody ke koupani a vody technologicke Stanoveni volneho a celkoveho chloru spektrofotometricky pomoci analyticke komercni soupravy AA19A (CSN ISO 7393-2)","search_en":"Drinking, surface, ground and waste water, bathing water and process water Determination of free and total chlorine by spectrophotometry using a commercial analytical kit AA19A (ČSN ISO 7393-2)","search_zh":"饮用水、地表水、地下水、废水、游泳/浴用水和工艺用水 商品分析试剂盒分光光度法测定游离氯和总氯 AA19A (ČSN ISO 7393-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b6cb3a4421676f328a65c24e","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"9","test_object":"Wody przeznaczone do spożycia i powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking and surface water, ground, waste and process water, leachates","test_object_zh":"饮用水和地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné a povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie anionów metodą chromatografii jonowej","methodology_en":"Determination of anions by ion chromatography","methodology_zh":"离子色谱法测定阴离子","methodology_cs":"Stanovení aniontů iontovou chromatografií","parameters":[{"name":"Fluorki","range":""},{"name":"chlorki","range":""},{"name":"azotyny","range":""},{"name":"azotany","range":""},{"name":"fosforany","range":""},{"name":"siarczany","range":""}],"parameters_en":[{"name":"Fluorides","range":""},{"name":"chlorides","range":""},{"name":"nitrites","range":""},{"name":"nitrates","range":""},{"name":"phosphates","range":""},{"name":"sulphates","range":""}],"parameters_zh":[{"name":"氟化物","range":""},{"name":"氯化物","range":""},{"name":"亚硝酸盐","range":""},{"name":"硝酸盐","range":""},{"name":"磷酸盐","range":""},{"name":"硫酸盐","range":""}],"parameters_cs":[{"name":"Fluoridy","range":""},{"name":"chloridy","range":""},{"name":"dusitany","range":""},{"name":"dusičnany","range":""},{"name":"fosforečnany","range":""},{"name":"sírany","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie anionów metodą chromatografii jonowej\nZakres:\nFluorki\nchlorki\nazotyny\nazotany\nfosforany\nsiarczany","reference":"AA20A (ČSN EN ISO 10304-1)","norm_bases":["AA20A","ČSN EN ISO 10304-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia i powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie anionów metodą chromatografii jonowej Fluorki  chlorki  azotyny  azotany  fosforany  siarczany  Vody pitné a povrchové, podzemní, odpadní a technologické, výluhy Stanovení aniontů iontovou chromatografií Fluoridy  chloridy  dusitany  dusičnany  fosforečnany  sírany  AA20A (ČSN EN ISO 10304-1) Wody przeznaczone do spozycia i powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie anionow metoda chromatografii jonowej Fluorki  chlorki  azotyny  azotany  fosforany  siarczany  Vody pitne a povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni aniontu iontovou chromatografii Fluoridy  chloridy  dusitany  dusicnany  fosforecnany  sirany  AA20A (CSN EN ISO 10304-1)","search_en":"Drinking and surface water, ground, waste and process water, leachates Determination of anions by ion chromatography Fluorides  chlorides  nitrites  nitrates  phosphates  sulphates  AA20A (ČSN EN ISO 10304-1)","search_zh":"饮用水和地表水、地下水、废水和工艺用水、浸出液 离子色谱法测定阴离子 氟化物  氯化物  亚硝酸盐  硝酸盐  磷酸盐  硫酸盐  AA20A (ČSN EN ISO 10304-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9f6dcb9a921dc7c5b57f7f10","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"10","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach, wody technologiczne i wyciągi","test_object_en":"Drinking, surface, ground and waste water, bathing water, process water and leachates","test_object_zh":"饮用水、地表水、地下水、废水、游泳/浴用水、工艺用水和浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní, vody ke koupání, vody technologické a výluhy","methodology":"Oznaczanie ogólnego i rozpuszczonego węgla organicznego (TOC, DOC) – analizator TOC","methodology_en":"Determination of total and dissolved organic carbon (TOC, DOC) – TOC analyser","methodology_zh":"总有机碳和溶解性有机碳（TOC、DOC）测定–TOC分析仪","methodology_cs":"Stanovení celkového a rozpuštěného organického uhlíku (TOC, DOC) – analyzátor TOC","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ogólnego i rozpuszczonego węgla organicznego (TOC, DOC) – analizator TOC","reference":"AS01A (ČSN EN 1484)","norm_bases":["AS01A","ČSN EN 1484"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach, wody technologiczne i wyciągi Oznaczanie ogólnego i rozpuszczonego węgla organicznego (TOC, DOC) – analizator TOC Vody pitné, povrchové, podzemní, odpadní, vody ke koupání, vody technologické a výluhy Stanovení celkového a rozpuštěného organického uhlíku (TOC, DOC) – analyzátor TOC AS01A (ČSN EN 1484) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wody w kapieliskach, wody technologiczne i wyciagi Oznaczanie ogolnego i rozpuszczonego wegla organicznego (TOC, DOC) – analizator TOC Vody pitne, povrchove, podzemni, odpadni, vody ke koupani, vody technologicke a vyluhy Stanoveni celkoveho a rozpusteneho organickeho uhliku (TOC, DOC) – analyzator TOC AS01A (CSN EN 1484)","search_en":"Drinking, surface, ground and waste water, bathing water, process water and leachates Determination of total and dissolved organic carbon (TOC, DOC) – TOC analyser AS01A (ČSN EN 1484)","search_zh":"饮用水、地表水、地下水、废水、游泳/浴用水、工艺用水和浸出液 总有机碳和溶解性有机碳（TOC、DOC）测定–TOC分析仪 AS01A (ČSN EN 1484)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b2fc3d82139a6fdc762681f9","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"11","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady","methodology":"Oznaczanie ogólnego węgla organicznego (TOC) – analizator TOC","methodology_en":"Determination of total organic carbon (TOC) – TOC analyser","methodology_zh":"总有机碳（TOC）测定–TOC分析仪","methodology_cs":"Stanovení celkového organického uhlíku (TOC) – analyzátor TOC","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ogólnego węgla organicznego (TOC) – analizator TOC","reference":"AS01B (ČSN EN 13137)","norm_bases":["AS01B","ČSN EN 13137"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe Oznaczanie ogólnego węgla organicznego (TOC) – analizator TOC Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady Stanovení celkového organického uhlíku (TOC) – analyzátor TOC AS01B (ČSN EN 13137) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale Oznaczanie ogolnego wegla organicznego (TOC) – analizator TOC Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady Stanoveni celkoveho organickeho uhliku (TOC) – analyzator TOC AS01B (CSN EN 13137)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste Determination of total organic carbon (TOC) – TOC analyser AS01B (ČSN EN 13137)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物 总有机碳（TOC）测定–TOC分析仪 AS01B (ČSN EN 13137)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"05c1418435b103db36f977ed","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"12","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną","methodology_en":"Determination of adsorbable organically bound halogens (AOX) by coulometry","methodology_zh":"库仑法测定可吸附有机卤素（AOX）","methodology_cs":"Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną","reference":"AS02A (ČSN EN ISO 9562)","norm_bases":["AS02A","ČSN EN ISO 9562"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky AS02A (ČSN EN ISO 9562) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie adsorbowalnych halogenow organicznie zwiazanych (AOX) metoda kulometryczna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni adsorbovatelnych organicky vazanych halogenu (AOX) coulometricky AS02A (CSN EN ISO 9562)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of adsorbable organically bound halogens (AOX) by coulometry AS02A (ČSN EN ISO 9562)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 库仑法测定可吸附有机卤素（AOX） AS02A (ČSN EN ISO 9562)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b660411b30dd7f137443a20a","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"13","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady","methodology":"Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną","methodology_en":"Determination of adsorbable organically bound halogens (AOX) by coulometry","methodology_zh":"库仑法测定可吸附有机卤素（AOX）","methodology_cs":"Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną","reference":"AS02B (DIN 38414S/18)","norm_bases":["AS02B","DIN 38414S/18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky AS02B (DIN 38414S/18) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale Oznaczanie adsorbowalnych halogenow organicznie zwiazanych (AOX) metoda kulometryczna Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady Stanoveni adsorbovatelnych organicky vazanych halogenu (AOX) coulometricky AS02B (DIN 38414S/18)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste Determination of adsorbable organically bound halogens (AOX) by coulometry AS02B (DIN 38414S/18)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物 库仑法测定可吸附有机卤素（AOX） AS02B (DIN 38414S/18)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e654a89505c44822f48fcc02","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"14","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie niepolarnych substancji ekstrahowalnych (NEL) i substancji ekstrahowalnych (EL) metodą FTIR","methodology_en":"Determination of non-polar extractable substances (NEL) and extractable substances (EL) by FTIR","methodology_zh":"FTIR法测定非极性可萃取物（NEL）和可萃取物（EL）","methodology_cs":"Stanovení nepolárních extrahovatelných látek (NEL) a extrahovatelných látek (EL) metodou FTIR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie niepolarnych substancji ekstrahowalnych (NEL) i substancji ekstrahowalnych (EL) metodą FTIR","reference":"AS03A (ČSN 75 7505; ČSN 75 7506)","norm_bases":["AS03A","ČSN 75 7505","ČSN 75 7506"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie niepolarnych substancji ekstrahowalnych (NEL) i substancji ekstrahowalnych (EL) metodą FTIR Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení nepolárních extrahovatelných látek (NEL) a extrahovatelných látek (EL) metodou FTIR AS03A (ČSN 75 7505; ČSN 75 7506) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie niepolarnych substancji ekstrahowalnych (NEL) i substancji ekstrahowalnych (EL) metoda FTIR Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni nepolarnich extrahovatelnych latek (NEL) a extrahovatelnych latek (EL) metodou FTIR AS03A (CSN 75 7505; CSN 75 7506)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of non-polar extractable substances (NEL) and extractable substances (EL) by FTIR AS03A (ČSN 75 7505; ČSN 75 7506)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 FTIR法测定非极性可萃取物（NEL）和可萃取物（EL） AS03A (ČSN 75 7505; ČSN 75 7506)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"87bbcd57c0bc4aad3a791a53","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"15","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady","methodology":"Oznaczanie niepolarnych substancji ekstrahowalnych (NEL) i substancji ekstrahowalnych (EL) metodą FTIR","methodology_en":"Determination of non-polar extractable substances (NEL) and extractable substances (EL) by FTIR","methodology_zh":"FTIR法测定非极性可萃取物（NEL）和可萃取物（EL）","methodology_cs":"Stanovení nepolárních extrahovatelných látek (NEL) a extrahovatelných látek (EL) metodou FTIR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie niepolarnych substancji ekstrahowalnych (NEL) i substancji ekstrahowalnych (EL) metodą FTIR","reference":"AS03B (TNV 75 8052)","norm_bases":["AS03B","TNV 75 8052"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe Oznaczanie niepolarnych substancji ekstrahowalnych (NEL) i substancji ekstrahowalnych (EL) metodą FTIR Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady Stanovení nepolárních extrahovatelných látek (NEL) a extrahovatelných látek (EL) metodou FTIR AS03B (TNV 75 8052) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale Oznaczanie niepolarnych substancji ekstrahowalnych (NEL) i substancji ekstrahowalnych (EL) metoda FTIR Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady Stanoveni nepolarnich extrahovatelnych latek (NEL) a extrahovatelnych latek (EL) metodou FTIR AS03B (TNV 75 8052)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste Determination of non-polar extractable substances (NEL) and extractable substances (EL) by FTIR AS03B (TNV 75 8052)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物 FTIR法测定非极性可萃取物（NEL）和可萃取物（EL） AS03B (TNV 75 8052)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6740c6e00e97c45e9d1286da","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"16","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie anionowych substancji powierzchniowo czynnych metodą spektrofotometryczną","methodology_en":"Determination of anionic surfactants by spectrophotometry","methodology_zh":"分光光度法测定阴离子表面活性剂","methodology_cs":"Stanovení anionaktivních tenzidů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie anionowych substancji powierzchniowo czynnych metodą spektrofotometryczną","reference":"AS04A (ČSN EN 903; ČSN EN ISO 16265)","norm_bases":["AS04A","ČSN EN 903","ČSN EN ISO 16265"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie anionowych substancji powierzchniowo czynnych metodą spektrofotometryczną Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení anionaktivních tenzidů spektrofotometricky AS04A (ČSN EN 903; ČSN EN ISO 16265) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie anionowych substancji powierzchniowo czynnych metoda spektrofotometryczna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni anionaktivnich tenzidu spektrofotometricky AS04A (CSN EN 903; CSN EN ISO 16265)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of anionic surfactants by spectrophotometry AS04A (ČSN EN 903; ČSN EN ISO 16265)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 分光光度法测定阴离子表面活性剂 AS04A (ČSN EN 903; ČSN EN ISO 16265)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"04b032f029bb87f28a6acc50","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"17","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną","methodology_en":"Determination of monohydric phenols by spectrophotometry","methodology_zh":"分光光度法测定一元酚","methodology_cs":"Stanovení jednosytných fenolů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną","reference":"AS05A (ČSN 83 0530-33)","norm_bases":["AS05A","ČSN 83 0530-33"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení jednosytných fenolů spektrofotometricky AS05A (ČSN 83 0530-33) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie fenoli jednowodorotlenowych metoda spektrofotometryczna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni jednosytnych fenolu spektrofotometricky AS05A (CSN 83 0530-33)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of monohydric phenols by spectrophotometry AS05A (ČSN 83 0530-33)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 分光光度法测定一元酚 AS05A (ČSN 83 0530-33)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"10bff1213d203f72d9ee4989","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"18","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie cyjanków ogólnych metodą spektrofotometryczną","methodology_en":"Determination of total cyanides by spectrophotometry","methodology_zh":"分光光度法测定总氰化物","methodology_cs":"Stanovení veškerých kyanidů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cyjanków ogólnych metodą spektrofotometryczną","reference":"AS06A (ČSN 75 7415; ČSN EN ISO 14403-1)","norm_bases":["AS06A","ČSN 75 7415","ČSN EN ISO 14403-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie cyjanków ogólnych metodą spektrofotometryczną Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení veškerých kyanidů spektrofotometricky AS06A (ČSN 75 7415; ČSN EN ISO 14403-1) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie cyjankow ogolnych metoda spektrofotometryczna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni veskerych kyanidu spektrofotometricky AS06A (CSN 75 7415; CSN EN ISO 14403-1)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of total cyanides by spectrophotometry AS06A (ČSN 75 7415; ČSN EN ISO 14403-1)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 分光光度法测定总氰化物 AS06A (ČSN 75 7415; ČSN EN ISO 14403-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"01167d822fbc3ffe15a798db","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"19","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie cyjanków łatwo uwalnialnych metodą spektrofotometryczną","methodology_en":"Determination of easily liberatable cyanides by spectrophotometry","methodology_zh":"分光光度法测定易释放氰化物","methodology_cs":"Stanovení snadno uvolnitelných kyanidů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cyjanków łatwo uwalnialnych metodą spektrofotometryczną","reference":"AS07A (ČSN ISO 6703-2; ČSN EN ISO 14403-1)","norm_bases":["AS07A","ČSN ISO 6703-2","ČSN EN ISO 14403-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie cyjanków łatwo uwalnialnych metodą spektrofotometryczną Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení snadno uvolnitelných kyanidů spektrofotometricky AS07A (ČSN ISO 6703-2; ČSN EN ISO 14403-1) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie cyjankow latwo uwalnialnych metoda spektrofotometryczna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni snadno uvolnitelnych kyanidu spektrofotometricky AS07A (CSN ISO 6703-2; CSN EN ISO 14403-1)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of easily liberatable cyanides by spectrophotometry AS07A (ČSN ISO 6703-2; ČSN EN ISO 14403-1)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 分光光度法测定易释放氰化物 AS07A (ČSN ISO 6703-2; ČSN EN ISO 14403-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"08f5a014162e5a425274e356","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"20","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dichromianową (miareczkowo)","methodology_en":"Determination of chemical oxygen demand by dichromate by titration","methodology_zh":"滴定法测定重铬酸盐化学需氧量","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dichromianową (miareczkowo)","reference":"AS08A (ČSN ISO 6060)","norm_bases":["AS08A","ČSN ISO 6060"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie chemicznego zapotrzebowania na tlen metodą dichromianową (miareczkowo) Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení chemické spotřeby kyslíku dichromanem titračně AS08A (ČSN ISO 6060) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie chemicznego zapotrzebowania na tlen metoda dichromianowa (miareczkowo) Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni chemicke spotreby kysliku dichromanem titracne AS08A (CSN ISO 6060)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of chemical oxygen demand by dichromate by titration AS08A (ČSN ISO 6060)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 滴定法测定重铬酸盐化学需氧量 AS08A (ČSN ISO 6060)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cdf8370a3771117ad6cab1e6","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"21","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach i wody technologiczne","test_object_en":"Drinking, surface, ground and waste water, bathing water and process water","test_object_zh":"饮用水、地表水、地下水、废水、游泳/浴用水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní, vody ke koupání a vody technologické","methodology":"Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (miareczkowo)","methodology_en":"Determination of chemical oxygen demand by permanganate by titration","methodology_zh":"滴定法测定高锰酸盐化学需氧量","methodology_cs":"Stanovení chemické spotřeby kyslíku manganistanem titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (miareczkowo)","reference":"AS09A (ČSN EN ISO 8467)","norm_bases":["AS09A","ČSN EN ISO 8467"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach i wody technologiczne Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (miareczkowo) Vody pitné, povrchové, podzemní, odpadní, vody ke koupání a vody technologické Stanovení chemické spotřeby kyslíku manganistanem titračně AS09A (ČSN EN ISO 8467) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wody w kapieliskach i wody technologiczne Oznaczanie chemicznego zapotrzebowania na tlen metoda nadmanganianowa (miareczkowo) Vody pitne, povrchove, podzemni, odpadni, vody ke koupani a vody technologicke Stanoveni chemicke spotreby kysliku manganistanem titracne AS09A (CSN EN ISO 8467)","search_en":"Drinking, surface, ground and waste water, bathing water and process water Determination of chemical oxygen demand by permanganate by titration AS09A (ČSN EN ISO 8467)","search_zh":"饮用水、地表水、地下水、废水、游泳/浴用水和工艺用水 滴定法测定高锰酸盐化学需氧量 AS09A (ČSN EN ISO 8467)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"772c27a9099df278cc87d627","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"22","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie biochemicznego zapotrzebowania na tlen metodą elektrochemiczną","methodology_en":"Determination of biochemical oxygen demand by electrochemistry","methodology_zh":"电化学法测定生化需氧量","methodology_cs":"Stanovení biochemické spotřeby kyslíku elektrochemicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania na tlen metodą elektrochemiczną","reference":"AS10A (ČSN EN 1899-1; ČSN EN 1899-2)","norm_bases":["AS10A","ČSN EN 1899-1","ČSN EN 1899-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie biochemicznego zapotrzebowania na tlen metodą elektrochemiczną Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení biochemické spotřeby kyslíku elektrochemicky AS10A (ČSN EN 1899-1; ČSN EN 1899-2) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie biochemicznego zapotrzebowania na tlen metoda elektrochemiczna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni biochemicke spotreby kysliku elektrochemicky AS10A (CSN EN 1899-1; CSN EN 1899-2)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of biochemical oxygen demand by electrochemistry AS10A (ČSN EN 1899-1; ČSN EN 1899-2)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 电化学法测定生化需氧量 AS10A (ČSN EN 1899-1; ČSN EN 1899-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bb035bc66d3e8cde1bb34d8f","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"23","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dichromianową (spektrofotometrycznie)","methodology_en":"Determination of chemical oxygen demand by dichromate by spectrophotometry","methodology_zh":"分光光度法测定重铬酸盐化学需氧量","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dichromianową (spektrofotometrycznie)","reference":"AS11A (ČSN ISO 15705)","norm_bases":["AS11A","ČSN ISO 15705"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie chemicznego zapotrzebowania na tlen metodą dichromianową (spektrofotometrycznie) Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení chemické spotřeby kyslíku dichromanem spektrofotometricky AS11A (ČSN ISO 15705) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie chemicznego zapotrzebowania na tlen metoda dichromianowa (spektrofotometrycznie) Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni chemicke spotreby kysliku dichromanem spektrofotometricky AS11A (CSN ISO 15705)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of chemical oxygen demand by dichromate by spectrophotometry AS11A (ČSN ISO 15705)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 分光光度法测定重铬酸盐化学需氧量 AS11A (ČSN ISO 15705)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f946dba3cf958ff51b53f9b4","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"24","test_object":"Materiał zwierzęcy i roślinny","test_object_en":"Animal and plant material","test_object_zh":"动物和植物材料","test_object_cs":"Živočišný a rostlinný materiál","methodology":"Oznaczanie zawartości tłuszczu metodą wagową","methodology_en":"Determination of fat content by gravimetry","methodology_zh":"重量法测定脂肪含量","methodology_cs":"Stanovení obsahu tuků gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości tłuszczu metodą wagową","reference":"AS20C (ČSN EN 1528-2)","norm_bases":["AS20C","ČSN EN 1528-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał zwierzęcy i roślinny Oznaczanie zawartości tłuszczu metodą wagową Živočišný a rostlinný materiál Stanovení obsahu tuků gravimetricky AS20C (ČSN EN 1528-2) Material zwierzecy i roslinny Oznaczanie zawartosci tluszczu metoda wagowa Zivocisny a rostlinny material Stanoveni obsahu tuku gravimetricky AS20C (CSN EN 1528-2)","search_en":"Animal and plant material Determination of fat content by gravimetry AS20C (ČSN EN 1528-2)","search_zh":"动物和植物材料 重量法测定脂肪含量 AS20C (ČSN EN 1528-2)","categories":["environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ec9e461e7485d3b199cf6d94","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"25","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach, wody technologiczne i wyciągi","test_object_en":"Drinking, surface, ground and waste water, bathing water, process water and leachates","test_object_zh":"饮用水、地表水、地下水、废水、游泳/浴用水、工艺用水和浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní, vody ke koupání, vody technologické a výluhy","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"pH测定（电位法）","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"AZ01A (ČSN ISO 10523)","norm_bases":["AZ01A","ČSN ISO 10523"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach, wody technologiczne i wyciągi Oznaczanie pH metodą potencjometryczną Vody pitné, povrchové, podzemní, odpadní, vody ke koupání, vody technologické a výluhy Stanovení pH potenciometricky AZ01A (ČSN ISO 10523) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wody w kapieliskach, wody technologiczne i wyciagi Oznaczanie pH metoda potencjometryczna Vody pitne, povrchove, podzemni, odpadni, vody ke koupani, vody technologicke a vyluhy Stanoveni pH potenciometricky AZ01A (CSN ISO 10523)","search_en":"Drinking, surface, ground and waste water, bathing water, process water and leachates Determination of pH by potentiometry AZ01A (ČSN ISO 10523)","search_zh":"饮用水、地表水、地下水、废水、游泳/浴用水、工艺用水和浸出液 pH测定（电位法） AZ01A (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8ea61a28378d7299740e7983","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"26","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne","test_object_en":"Drinking, surface, ground, waste and process water","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické","methodology":"Oznaczanie zdolności neutralizacji kwasów (KNK) metodą miareczkową i obliczenie form CO2 z wartości zmierzonych","methodology_en":"Determination of acid neutralising capacity (KNK) by titration and calculation of CO2 forms from measured values","methodology_zh":"滴定法测定酸中和能力（KNK）并由测量值计算CO2形态","methodology_cs":"Stanovení kyselinové neutralizační kapacity (KNK) titračně a výpočet forem CO2 z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zdolności neutralizacji kwasów (KNK) metodą miareczkową i obliczenie form CO2 z wartości zmierzonych","reference":"AZ02A (ČSN EN ISO 9963-1; ČSN 75 7373)","norm_bases":["AZ02A","ČSN EN ISO 9963-1","ČSN 75 7373"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne Oznaczanie zdolności neutralizacji kwasów (KNK) metodą miareczkową i obliczenie form CO2 z wartości zmierzonych Vody pitné, povrchové, podzemní, odpadní a technologické Stanovení kyselinové neutralizační kapacity (KNK) titračně a výpočet forem CO2 z naměřených hodnot AZ02A (ČSN EN ISO 9963-1; ČSN 75 7373) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne Oznaczanie zdolnosci neutralizacji kwasow (KNK) metoda miareczkowa i obliczenie form CO2 z wartosci zmierzonych Vody pitne, povrchove, podzemni, odpadni a technologicke Stanoveni kyselinove neutralizacni kapacity (KNK) titracne a vypocet forem CO2 z namerenych hodnot AZ02A (CSN EN ISO 9963-1; CSN 75 7373)","search_en":"Drinking, surface, ground, waste and process water Determination of acid neutralising capacity (KNK) by titration and calculation of CO2 forms from measured values AZ02A (ČSN EN ISO 9963-1; ČSN 75 7373)","search_zh":"饮用水、地表水、地下水、废水和工艺用水 滴定法测定酸中和能力（KNK）并由测量值计算CO2形态 AZ02A (ČSN EN ISO 9963-1; ČSN 75 7373)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"66acba5417edca19c5e388b6","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"27","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne","test_object_en":"Drinking, surface, ground, waste and process water","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické","methodology":"Oznaczanie zdolności neutralizacji zasad (ZNK) metodą miareczkową","methodology_en":"Determination of base neutralising capacity (ZNK) by titration","methodology_zh":"滴定法测定碱中和能力（ZNK）","methodology_cs":"Stanovení zásadové neutralizační kapacity (ZNK) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zdolności neutralizacji zasad (ZNK) metodą miareczkową","reference":"AZ03A (ČSN 75 7372)","norm_bases":["AZ03A","ČSN 75 7372"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne Oznaczanie zdolności neutralizacji zasad (ZNK) metodą miareczkową Vody pitné, povrchové, podzemní, odpadní a technologické Stanovení zásadové neutralizační kapacity (ZNK) titračně AZ03A (ČSN 75 7372) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne Oznaczanie zdolnosci neutralizacji zasad (ZNK) metoda miareczkowa Vody pitne, povrchove, podzemni, odpadni a technologicke Stanoveni zasadove neutralizacni kapacity (ZNK) titracne AZ03A (CSN 75 7372)","search_en":"Drinking, surface, ground, waste and process water Determination of base neutralising capacity (ZNK) by titration AZ03A (ČSN 75 7372)","search_zh":"饮用水、地表水、地下水、废水和工艺用水 滴定法测定碱中和能力（ZNK） AZ03A (ČSN 75 7372)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"504a24b567e25c013a4a2413","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"28","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie przewodności elektrycznej właściwej metodą konduktometryczną","methodology_en":"Determination of electrical conductivity by conductometry","methodology_zh":"电导率测定（电导法）","methodology_cs":"Stanovení elektrické konduktivity konduktometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej właściwej metodą konduktometryczną","reference":"AZ04A (ČSN EN 27888)","norm_bases":["AZ04A","ČSN EN 27888"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie przewodności elektrycznej właściwej metodą konduktometryczną Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení elektrické konduktivity konduktometricky AZ04A (ČSN EN 27888) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie przewodnosci elektrycznej wlasciwej metoda konduktometryczna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni elektricke konduktivity konduktometricky AZ04A (CSN EN 27888)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of electrical conductivity by conductometry AZ04A (ČSN EN 27888)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 电导率测定（电导法） AZ04A (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"082cdb3b5a12fb9948cf6e79","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"29","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie substancji rozpuszczonych i zawiesiny, rozpuszczonych soli nieorganicznych metodą wagową","methodology_en":"Determination of dissolved and suspended solids and dissolved inorganic salts by gravimetry","methodology_zh":"重量法测定溶解性物质、悬浮物和溶解性无机盐","methodology_cs":"Stanovení rozpuštěných a nerozpuštěných látek, rozpuštěných anorganických solí gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych i zawiesiny, rozpuszczonych soli nieorganicznych metodą wagową","reference":"AZ05A (ČSN 75 7346; ČSN EN 872; ČSN 75 7347)","norm_bases":["AZ05A","ČSN 75 7346","ČSN EN 872","ČSN 75 7347"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie substancji rozpuszczonych i zawiesiny, rozpuszczonych soli nieorganicznych metodą wagową Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení rozpuštěných a nerozpuštěných látek, rozpuštěných anorganických solí gravimetricky AZ05A (ČSN 75 7346; ČSN EN 872; ČSN 75 7347) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie substancji rozpuszczonych i zawiesiny, rozpuszczonych soli nieorganicznych metoda wagowa Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni rozpustenych a nerozpustenych latek, rozpustenych anorganickych soli gravimetricky AZ05A (CSN 75 7346; CSN EN 872; CSN 75 7347)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of dissolved and suspended solids and dissolved inorganic salts by gravimetry AZ05A (ČSN 75 7346; ČSN EN 872; ČSN 75 7347)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 重量法测定溶解性物质、悬浮物和溶解性无机盐 AZ05A (ČSN 75 7346; ČSN EN 872; ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0f95763756e8f6ec9b22f533","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"30","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach i wody technologiczne","test_object_en":"Drinking, surface, ground and waste water, bathing water and process water","test_object_zh":"饮用水、地表水、地下水、废水、游泳/浴用水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní, vody ke koupání a vody technologické","methodology":"Oznaczanie mętności metodą turbidymetryczną","methodology_en":"Determination of turbidity by turbidimetry","methodology_zh":"比浊法测定浊度","methodology_cs":"Stanovení zákalu turbidimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mętności metodą turbidymetryczną","reference":"AZ06A – metoda 1 (ČSN EN ISO 7027-1)","norm_bases":["AZ06A – metoda 1","ČSN EN ISO 7027-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach i wody technologiczne Oznaczanie mętności metodą turbidymetryczną Vody pitné, povrchové, podzemní, odpadní, vody ke koupání a vody technologické Stanovení zákalu turbidimetricky AZ06A – metoda 1 (ČSN EN ISO 7027-1) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wody w kapieliskach i wody technologiczne Oznaczanie metnosci metoda turbidymetryczna Vody pitne, povrchove, podzemni, odpadni, vody ke koupani a vody technologicke Stanoveni zakalu turbidimetricky AZ06A – metoda 1 (CSN EN ISO 7027-1)","search_en":"Drinking, surface, ground and waste water, bathing water and process water Determination of turbidity by turbidimetry AZ06A – metoda 1 (ČSN EN ISO 7027-1)","search_zh":"饮用水、地表水、地下水、废水、游泳/浴用水和工艺用水 比浊法测定浊度 AZ06A – metoda 1 (ČSN EN ISO 7027-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"acde76d2ca03cee2e129dedb","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"31","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach i wody technologiczne","test_object_en":"Drinking, surface, ground and waste water, bathing water and process water","test_object_zh":"饮用水、地表水、地下水、废水、游泳/浴用水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní, vody ke koupání a vody technologické","methodology":"Oznaczanie mętności metodą nefelometryczną","methodology_en":"Determination of turbidity by nephelometry","methodology_zh":"散射比浊法测定浊度","methodology_cs":"Stanovení zákalu nefelometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mętności metodą nefelometryczną","reference":"AZ06A – metoda 2 (ČSN EN ISO 7027-1)","norm_bases":["AZ06A – metoda 2","ČSN EN ISO 7027-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody w kąpieliskach i wody technologiczne Oznaczanie mętności metodą nefelometryczną Vody pitné, povrchové, podzemní, odpadní, vody ke koupání a vody technologické Stanovení zákalu nefelometricky AZ06A – metoda 2 (ČSN EN ISO 7027-1) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wody w kapieliskach i wody technologiczne Oznaczanie metnosci metoda nefelometryczna Vody pitne, povrchove, podzemni, odpadni, vody ke koupani a vody technologicke Stanoveni zakalu nefelometricky AZ06A – metoda 2 (CSN EN ISO 7027-1)","search_en":"Drinking, surface, ground and waste water, bathing water and process water Determination of turbidity by nephelometry AZ06A – metoda 2 (ČSN EN ISO 7027-1)","search_zh":"饮用水、地表水、地下水、废水、游泳/浴用水和工艺用水 散射比浊法测定浊度 AZ06A – metoda 2 (ČSN EN ISO 7027-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6f298ca8b627b92dbae1d32e","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"32","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie absorbancji metodą spektrofotometryczną","methodology_en":"Determination of absorbance by spectrophotometry","methodology_zh":"分光光度法测定吸光度","methodology_cs":"Stanovení absorbance spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie absorbancji metodą spektrofotometryczną","reference":"AZ07A (ČSN 75 7360)","norm_bases":["AZ07A","ČSN 75 7360"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie absorbancji metodą spektrofotometryczną Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení absorbance spektrofotometricky AZ07A (ČSN 75 7360) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie absorbancji metoda spektrofotometryczna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni absorbance spektrofotometricky AZ07A (CSN 75 7360)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of absorbance by spectrophotometry AZ07A (ČSN 75 7360)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 分光光度法测定吸光度 AZ07A (ČSN 75 7360)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"59b85f8d79fd55510a7a0b39","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"33","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne","test_object_en":"Drinking, surface, ground, waste and process water","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické","methodology":"Oznaczanie tlenu rozpuszczonego metodą elektrochemiczną i nasycenia tlenem","methodology_en":"Determination of dissolved oxygen by electrochemistry and oxygen saturation","methodology_zh":"电化学法测定溶解氧和氧饱和度","methodology_cs":"Stanovení rozpuštěného kyslíku elektrochemicky a nasycení kyslíkem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tlenu rozpuszczonego metodą elektrochemiczną i nasycenia tlenem","reference":"AZ08A (ČSN EN 25814)","norm_bases":["AZ08A","ČSN EN 25814"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne Oznaczanie tlenu rozpuszczonego metodą elektrochemiczną i nasycenia tlenem Vody pitné, povrchové, podzemní, odpadní a technologické Stanovení rozpuštěného kyslíku elektrochemicky a nasycení kyslíkem AZ08A (ČSN EN 25814) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne Oznaczanie tlenu rozpuszczonego metoda elektrochemiczna i nasycenia tlenem Vody pitne, povrchove, podzemni, odpadni a technologicke Stanoveni rozpusteneho kysliku elektrochemicky a nasyceni kyslikem AZ08A (CSN EN 25814)","search_en":"Drinking, surface, ground, waste and process water Determination of dissolved oxygen by electrochemistry and oxygen saturation AZ08A (ČSN EN 25814)","search_zh":"饮用水、地表水、地下水、废水和工艺用水 电化学法测定溶解氧和氧饱和度 AZ08A (ČSN EN 25814)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b55d8c3a7b04c8907d58959b","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"34","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne","test_object_en":"Drinking, surface, ground, waste and process water","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické","methodology":"Oznaczanie barwy metodą spektrofotometryczną","methodology_en":"Determination of colour by spectrophotometry","methodology_zh":"分光光度法测定色度","methodology_cs":"Stanovení barvy spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie barwy metodą spektrofotometryczną","reference":"AZ10A (ČSN EN ISO 7887)","norm_bases":["AZ10A","ČSN EN ISO 7887"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne Oznaczanie barwy metodą spektrofotometryczną Vody pitné, povrchové, podzemní, odpadní a technologické Stanovení barvy spektrofotometricky AZ10A (ČSN EN ISO 7887) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne Oznaczanie barwy metoda spektrofotometryczna Vody pitne, povrchove, podzemni, odpadni a technologicke Stanoveni barvy spektrofotometricky AZ10A (CSN EN ISO 7887)","search_en":"Drinking, surface, ground, waste and process water Determination of colour by spectrophotometry AZ10A (ČSN EN ISO 7887)","search_zh":"饮用水、地表水、地下水、废水和工艺用水 分光光度法测定色度 AZ10A (ČSN EN ISO 7887)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3be2f62f1163ca1cfd5958c6","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"35","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady","methodology":"Oznaczanie suchej masy i straty prażenia metodą wagową","methodology_en":"Determination of dry matter and loss on ignition by gravimetry","methodology_zh":"重量法测定干物质和灼烧损失","methodology_cs":"Stanovení sušiny a ztráty žíháním gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie suchej masy i straty prażenia metodą wagową","reference":"AZ14B (ČSN EN 12879; ČSN EN 12880)","norm_bases":["AZ14B","ČSN EN 12879","ČSN EN 12880"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe Oznaczanie suchej masy i straty prażenia metodą wagową Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady Stanovení sušiny a ztráty žíháním gravimetricky AZ14B (ČSN EN 12879; ČSN EN 12880) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale Oznaczanie suchej masy i straty prazenia metoda wagowa Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady Stanoveni susiny a ztraty zihanim gravimetricky AZ14B (CSN EN 12879; CSN EN 12880)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste Determination of dry matter and loss on ignition by gravimetry AZ14B (ČSN EN 12879; ČSN EN 12880)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物 重量法测定干物质和灼烧损失 AZ14B (ČSN EN 12879; ČSN EN 12880)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"48a0fb289f119a640429af50","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"36","test_object":"Materiał zwierzęcy i roślinny","test_object_en":"Animal and plant material","test_object_zh":"动物和植物材料","test_object_cs":"Živočišný a rostlinný materiál","methodology":"Oznaczanie suchej masy i straty prażenia metodą wagową","methodology_en":"Determination of dry matter and loss on ignition by gravimetry","methodology_zh":"重量法测定干物质和灼烧损失","methodology_cs":"Stanovení sušiny a ztráty žíháním gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie suchej masy i straty prażenia metodą wagową","reference":"AZ14C (ČSN EN 12879; ČSN EN 12880)","norm_bases":["AZ14C","ČSN EN 12879","ČSN EN 12880"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał zwierzęcy i roślinny Oznaczanie suchej masy i straty prażenia metodą wagową Živočišný a rostlinný materiál Stanovení sušiny a ztráty žíháním gravimetricky AZ14C (ČSN EN 12879; ČSN EN 12880) Material zwierzecy i roslinny Oznaczanie suchej masy i straty prazenia metoda wagowa Zivocisny a rostlinny material Stanoveni susiny a ztraty zihanim gravimetricky AZ14C (CSN EN 12879; CSN EN 12880)","search_en":"Animal and plant material Determination of dry matter and loss on ignition by gravimetry AZ14C (ČSN EN 12879; ČSN EN 12880)","search_zh":"动物和植物材料 重量法测定干物质和灼烧损失 AZ14C (ČSN EN 12879; ČSN EN 12880)","categories":["environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7549a12aa98bd9847e3bd6f1","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"37","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne","test_object_en":"Drinking, surface, ground, waste and process water","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické","methodology":"Oznaczanie temperatury","methodology_en":"Determination of temperature","methodology_zh":"温度测定","methodology_cs":"Stanovení teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury","reference":"AZ15A (ČSN 75 7342)","norm_bases":["AZ15A","ČSN 75 7342"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne Oznaczanie temperatury Vody pitné, povrchové, podzemní, odpadní a technologické Stanovení teploty AZ15A (ČSN 75 7342) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne Oznaczanie temperatury Vody pitne, povrchove, podzemni, odpadni a technologicke Stanoveni teploty AZ15A (CSN 75 7342)","search_en":"Drinking, surface, ground, waste and process water Determination of temperature AZ15A (ČSN 75 7342)","search_zh":"饮用水、地表水、地下水、废水和工艺用水 温度测定 AZ15A (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a8e571df6d4e36657b3de6d8","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"38","test_object":"Osady denne","test_object_en":"Sediments","test_object_zh":"沉积物","test_object_cs":"Sedimenty","methodology":"Oznaczanie zawartości szkieletu metodą wagową","methodology_en":"Determination of skeleton (coarse fraction) content by gravimetry","methodology_zh":"重量法测定骨架（粗粒）含量","methodology_cs":"Stanovení obsahu skeletu gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości szkieletu metodą wagową","reference":"AZ19B – metoda 1 (Vyhláška č. 257/2009 Sb.)","norm_bases":["AZ19B – metoda 1","Vyhláška č. 257/2009 Sb."],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady denne Oznaczanie zawartości szkieletu metodą wagową Sedimenty Stanovení obsahu skeletu gravimetricky AZ19B – metoda 1 (Vyhláška č. 257/2009 Sb.) Osady denne Oznaczanie zawartosci szkieletu metoda wagowa Sedimenty Stanoveni obsahu skeletu gravimetricky AZ19B – metoda 1 (Vyhlaska c. 257/2009 Sb.)","search_en":"Sediments Determination of skeleton (coarse fraction) content by gravimetry AZ19B – metoda 1 (Vyhláška č. 257/2009 Sb.)","search_zh":"沉积物 重量法测定骨架（粗粒）含量 AZ19B – metoda 1 (Vyhláška č. 257/2009 Sb.)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d8deb2875972d40b2a5a64d5","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"39","test_object":"Osady denne","test_object_en":"Sediments","test_object_zh":"沉积物","test_object_cs":"Sedimenty","methodology":"Oznaczanie zawartości szkieletu metodą objętościową","methodology_en":"Determination of skeleton (coarse fraction) content by volumetry","methodology_zh":"容积法测定骨架（粗粒）含量","methodology_cs":"Stanovení obsahu skeletu volumetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości szkieletu metodą objętościową","reference":"AZ19B – metoda 2 (Vyhláška č. 257/2009 Sb.)","norm_bases":["AZ19B – metoda 2","Vyhláška č. 257/2009 Sb."],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady denne Oznaczanie zawartości szkieletu metodą objętościową Sedimenty Stanovení obsahu skeletu volumetricky AZ19B – metoda 2 (Vyhláška č. 257/2009 Sb.) Osady denne Oznaczanie zawartosci szkieletu metoda objetosciowa Sedimenty Stanoveni obsahu skeletu volumetricky AZ19B – metoda 2 (Vyhlaska c. 257/2009 Sb.)","search_en":"Sediments Determination of skeleton (coarse fraction) content by volumetry AZ19B – metoda 2 (Vyhláška č. 257/2009 Sb.)","search_zh":"沉积物 容积法测定骨架（粗粒）含量 AZ19B – metoda 2 (Vyhláška č. 257/2009 Sb.)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b4932c31c0b1fba07abafb97","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"40","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie metali (Na, K) metodą AES","methodology_en":"Determination of metals (Na, K) by AES","methodology_zh":"AES法测定金属（Na、K）","methodology_cs":"Stanovení kovů (Na, K) metodou AES","parameters":[{"name":"Sód (Na)","range":""},{"name":"Potas (K)","range":""}],"parameters_en":[{"name":"Sodium (Na)","range":""},{"name":"Potassium (K)","range":""}],"parameters_zh":[{"name":"钠（Na）","range":""},{"name":"钾（K）","range":""}],"parameters_cs":[{"name":"Na","range":""},{"name":"K","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali (Na, K) metodą AES\nZakres:\nSód (Na)\nPotas (K)","reference":"AK02A (ČSN ISO 9964-3)","norm_bases":["AK02A","ČSN ISO 9964-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie metali (Na, K) metodą AES Sód (Na)  Potas (K)  Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení kovů (Na, K) metodou AES Na  K  AK02A (ČSN ISO 9964-3) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie metali (Na, K) metoda AES Sod (Na)  Potas (K)  Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni kovu (Na, K) metodou AES Na  K  AK02A (CSN ISO 9964-3)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of metals (Na, K) by AES Sodium (Na)  Potassium (K)  AK02A (ČSN ISO 9964-3)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 AES法测定金属（Na、K） 钠（Na）  钾（K）  AK02A (ČSN ISO 9964-3)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ded99a978d52368d02010b3a","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"41","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie rtęci (analizator jednozadaniowy)","methodology_en":"Determination of mercury (dedicated analyser)","methodology_zh":"测定汞（专用分析仪）","methodology_cs":"Stanovení rtuti (jednoúčelový analyzátor)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci (analizator jednozadaniowy)","reference":"AK05A (ČSN 75 7440)","norm_bases":["AK05A","ČSN 75 7440"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie rtęci (analizator jednozadaniowy) Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení rtuti (jednoúčelový analyzátor) AK05A (ČSN 75 7440) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie rteci (analizator jednozadaniowy) Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni rtuti (jednoucelovy analyzator) AK05A (CSN 75 7440)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of mercury (dedicated analyser) AK05A (ČSN 75 7440)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 测定汞（专用分析仪） AK05A (ČSN 75 7440)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"670f4b5dd517333ae1262d4e","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"42","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, medium sorpcyjne próbnika pasywnego","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, receiving phase of a passive sampler","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器吸附介质","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, zachycovací medium pasivního vzorkovače","methodology":"Oznaczanie rtęci (analizator jednozadaniowy)","methodology_en":"Determination of mercury (dedicated analyser)","methodology_zh":"测定汞（专用分析仪）","methodology_cs":"Stanovení rtuti (jednoúčelový analyzátor)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci (analizator jednozadaniowy)","reference":"AK05B (ČSN 75 7440)","norm_bases":["AK05B","ČSN 75 7440"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, medium sorpcyjne próbnika pasywnego Oznaczanie rtęci (analizator jednozadaniowy) Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, zachycovací medium pasivního vzorkovače Stanovení rtuti (jednoúčelový analyzátor) AK05B (ČSN 75 7440) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale, medium sorpcyjne probnika pasywnego Oznaczanie rteci (analizator jednozadaniowy) Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady, zachycovaci medium pasivniho vzorkovace Stanoveni rtuti (jednoucelovy analyzator) AK05B (CSN 75 7440)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, receiving phase of a passive sampler Determination of mercury (dedicated analyser) AK05B (ČSN 75 7440)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器吸附介质 测定汞（专用分析仪） AK05B (ČSN 75 7440)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1df7ee5d2c24d3acd5a900a6","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"43","test_object":"Materiał zwierzęcy i roślinny","test_object_en":"Animal and plant material","test_object_zh":"动物和植物材料","test_object_cs":"Živočišný a rostlinný materiál","methodology":"Oznaczanie rtęci (analizator jednozadaniowy)","methodology_en":"Determination of mercury (dedicated analyser)","methodology_zh":"测定汞（专用分析仪）","methodology_cs":"Stanovení rtuti (jednoúčelový analyzátor)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci (analizator jednozadaniowy)","reference":"AK05C (ČSN 75 7440)","norm_bases":["AK05C","ČSN 75 7440"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał zwierzęcy i roślinny Oznaczanie rtęci (analizator jednozadaniowy) Živočišný a rostlinný materiál Stanovení rtuti (jednoúčelový analyzátor) AK05C (ČSN 75 7440) Material zwierzecy i roslinny Oznaczanie rteci (analizator jednozadaniowy) Zivocisny a rostlinny material Stanoveni rtuti (jednoucelovy analyzator) AK05C (CSN 75 7440)","search_en":"Animal and plant material Determination of mercury (dedicated analyser) AK05C (ČSN 75 7440)","search_zh":"动物和植物材料 测定汞（专用分析仪） AK05C (ČSN 75 7440)","categories":["environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"533e63e548b6890ee50c5d38","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"44","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie CrVI+ metodą spektrofotometryczną","methodology_en":"Determination of CrVI+ by spectrophotometry","methodology_zh":"分光光度法测定CrVI+","methodology_cs":"Stanovení CrVI+ spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie CrVI+ metodą spektrofotometryczną","reference":"AK06A (ČSN ISO 18412)","norm_bases":["AK06A","ČSN ISO 18412"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie CrVI+ metodą spektrofotometryczną Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení CrVI+ spektrofotometricky AK06A (ČSN ISO 18412) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie CrVI+ metoda spektrofotometryczna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni CrVI+ spektrofotometricky AK06A (CSN ISO 18412)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of CrVI+ by spectrophotometry AK06A (ČSN ISO 18412)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 分光光度法测定CrVI+ AK06A (ČSN ISO 18412)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5d8fcbc8797aacb1c2543308","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"45","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie metali i fosforu metodą (ICP/OES) i obliczenie mineralizacji ogólnej z wartości zmierzonych","methodology_en":"Determination of metals and phosphorus by (ICP/OES) and calculation of total mineralisation from measured values","methodology_zh":"（ICP/OES）法测定金属和磷并由测量值计算总矿化度","methodology_cs":"Stanovení kovů a fosforu metodou (ICP/OES) a výpočet celkové mineralizace z naměřených hodnot","parameters":[{"name":"Glin (Al)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Lit (Li)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Sód (Na)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Stront (Sr)","range":""},{"name":"Tytan (Ti)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Fosfor (P)","range":""}],"parameters_en":[{"name":"Aluminium (Al)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Lithium (Li)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Strontium (Sr)","range":""},{"name":"Titanium (Ti)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Phosphorus (P)","range":""}],"parameters_zh":[{"name":"铝（Al）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"锂（Li）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钠（Na）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"锶（Sr）","range":""},{"name":"钛（Ti）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""},{"name":"磷（P）","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Li","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"Sr","range":""},{"name":"Ti","range":""},{"name":"V","range":""},{"name":"Zn","range":""},{"name":"P","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali i fosforu metodą (ICP/OES) i obliczenie mineralizacji ogólnej z wartości zmierzonych\nZakres:\nGlin (Al)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nLit (Li)\nMagnez (Mg)\nMangan (Mn)\nSód (Na)\nNikiel (Ni)\nOłów (Pb)\nStront (Sr)\nTytan (Ti)\nWanad (V)\nCynk (Zn)\nFosfor (P)","reference":"AK12A (ČSN EN ISO 11885; ČSN 75 7358)","norm_bases":["AK12A","ČSN EN ISO 11885","ČSN 75 7358"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie metali i fosforu metodą (ICP/OES) i obliczenie mineralizacji ogólnej z wartości zmierzonych Glin (Al)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Lit (Li)  Magnez (Mg)  Mangan (Mn)  Sód (Na)  Nikiel (Ni)  Ołów (Pb)  Stront (Sr)  Tytan (Ti)  Wanad (V)  Cynk (Zn)  Fosfor (P)  Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení kovů a fosforu metodou (ICP/OES) a výpočet celkové mineralizace z naměřených hodnot Al  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Li  Mg  Mn  Na  Ni  Pb  Sr  Ti  V  Zn  P  AK12A (ČSN EN ISO 11885; ČSN 75 7358) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie metali i fosforu metoda (ICP/OES) i obliczenie mineralizacji ogolnej z wartosci zmierzonych Glin (Al)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Lit (Li)  Magnez (Mg)  Mangan (Mn)  Sod (Na)  Nikiel (Ni)  Olow (Pb)  Stront (Sr)  Tytan (Ti)  Wanad (V)  Cynk (Zn)  Fosfor (P)  Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni kovu a fosforu metodou (ICP/OES) a vypocet celkove mineralizace z namerenych hodnot Al  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Li  Mg  Mn  Na  Ni  Pb  Sr  Ti  V  Zn  P  AK12A (CSN EN ISO 11885; CSN 75 7358)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of metals and phosphorus by (ICP/OES) and calculation of total mineralisation from measured values Aluminium (Al)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Lithium (Li)  Magnesium (Mg)  Manganese (Mn)  Sodium (Na)  Nickel (Ni)  Lead (Pb)  Strontium (Sr)  Titanium (Ti)  Vanadium (V)  Zinc (Zn)  Phosphorus (P)  AK12A (ČSN EN ISO 11885; ČSN 75 7358)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 （ICP/OES）法测定金属和磷并由测量值计算总矿化度 铝（Al）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  锂（Li）  镁（Mg）  锰（Mn）  钠（Na）  镍（Ni）  铅（Pb）  锶（Sr）  钛（Ti）  钒（V）  锌（Zn）  磷（P）  AK12A (ČSN EN ISO 11885; ČSN 75 7358)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6934b2db02b80845d575abd7","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"46","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, medium sorpcyjne próbnika pasywnego","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, receiving phase of a passive sampler","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器吸附介质","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, zachycovací medium pasivního vzorkovače","methodology":"Oznaczanie metali i fosforu metodą ICP/OES","methodology_en":"Determination of metals and phosphorus by ICP/OES","methodology_zh":"ICP/OES法测定金属和磷","methodology_cs":"Stanovení kovů a fosforu metodou ICP/OES","parameters":[{"name":"Glin (Al)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Sód (Na)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Fosfor (P)","range":""}],"parameters_en":[{"name":"Aluminium (Al)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Phosphorus (P)","range":""}],"parameters_zh":[{"name":"铝（Al）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钠（Na）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""},{"name":"磷（P）","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"V","range":""},{"name":"Zn","range":""},{"name":"P","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali i fosforu metodą ICP/OES\nZakres:\nGlin (Al)\nBor (B)\nBar (Ba)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nSód (Na)\nNikiel (Ni)\nOłów (Pb)\nWanad (V)\nCynk (Zn)\nFosfor (P)","reference":"AK12B (DIN 38406 – E22)","norm_bases":["AK12B","DIN 38406 – E22"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, medium sorpcyjne próbnika pasywnego Oznaczanie metali i fosforu metodą ICP/OES Glin (Al)  Bor (B)  Bar (Ba)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Sód (Na)  Nikiel (Ni)  Ołów (Pb)  Wanad (V)  Cynk (Zn)  Fosfor (P)  Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, zachycovací medium pasivního vzorkovače Stanovení kovů a fosforu metodou ICP/OES Al  B  Ba  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Na  Ni  Pb  V  Zn  P  AK12B (DIN 38406 – E22) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale, medium sorpcyjne probnika pasywnego Oznaczanie metali i fosforu metoda ICP/OES Glin (Al)  Bor (B)  Bar (Ba)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Sod (Na)  Nikiel (Ni)  Olow (Pb)  Wanad (V)  Cynk (Zn)  Fosfor (P)  Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady, zachycovaci medium pasivniho vzorkovace Stanoveni kovu a fosforu metodou ICP/OES Al  B  Ba  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Na  Ni  Pb  V  Zn  P  AK12B (DIN 38406 – E22)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, receiving phase of a passive sampler Determination of metals and phosphorus by ICP/OES Aluminium (Al)  Boron (B)  Barium (Ba)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Sodium (Na)  Nickel (Ni)  Lead (Pb)  Vanadium (V)  Zinc (Zn)  Phosphorus (P)  AK12B (DIN 38406 – E22)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器吸附介质 ICP/OES法测定金属和磷 铝（Al）  硼（B）  钡（Ba）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  钠（Na）  镍（Ni）  铅（Pb）  钒（V）  锌（Zn）  磷（P）  AK12B (DIN 38406 – E22)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"589674317f0c8a0532535fe3","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"47","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie rtęci (analizator jednozadaniowy Mercur)","methodology_en":"Determination of mercury (dedicated Mercur analyser)","methodology_zh":"测定汞（Mercur专用分析仪）","methodology_cs":"Stanovení rtuti (jednoúčelový analyzátor Mercur)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci (analizator jednozadaniowy Mercur)","reference":"AK17A (ČSN 75 7440)","norm_bases":["AK17A","ČSN 75 7440"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie rtęci (analizator jednozadaniowy Mercur) Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení rtuti (jednoúčelový analyzátor Mercur) AK17A (ČSN 75 7440) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie rteci (analizator jednozadaniowy Mercur) Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni rtuti (jednoucelovy analyzator Mercur) AK17A (CSN 75 7440)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of mercury (dedicated Mercur analyser) AK17A (ČSN 75 7440)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 测定汞（Mercur专用分析仪） AK17A (ČSN 75 7440)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"741fa63192eb3cce2b714375","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"48","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie metali metodą ICP/MS z analizatorem kwadrupolowym","methodology_en":"Determination of metals by quadrupole ICP/MS","methodology_zh":"四极杆ICP/MS法测定金属","methodology_cs":"Stanovení kovů metodou ICP/MS-Quadrupole","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Lit (Li)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Stront (Sr)","range":""},{"name":"Tytan (Ti)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Uran (U)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Lithium (Li)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Strontium (Sr)","range":""},{"name":"Titanium (Ti)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Uranium (U)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"锂（Li）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"硒（Se）","range":""},{"name":"锑（Sb）","range":""},{"name":"锡（Sn）","range":""},{"name":"锶（Sr）","range":""},{"name":"钛（Ti）","range":""},{"name":"铊（Tl）","range":""},{"name":"铀（U）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"Li","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"Se","range":""},{"name":"Sb","range":""},{"name":"Sn","range":""},{"name":"Sr","range":""},{"name":"Ti","range":""},{"name":"Tl","range":""},{"name":"U","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali metodą ICP/MS z analizatorem kwadrupolowym\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nLit (Li)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nNikiel (Ni)\nOłów (Pb)\nSelen (Se)\nAntymon (Sb)\nCyna (Sn)\nStront (Sr)\nTytan (Ti)\nTal (Tl)\nUran (U)\nWanad (V)\nCynk (Zn)","reference":"AK18A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)","norm_bases":["AK18A","ČSN EN ISO 17294-1","ČSN EN ISO 17294-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie metali metodą ICP/MS z analizatorem kwadrupolowym Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Lit (Li)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Nikiel (Ni)  Ołów (Pb)  Selen (Se)  Antymon (Sb)  Cyna (Sn)  Stront (Sr)  Tytan (Ti)  Tal (Tl)  Uran (U)  Wanad (V)  Cynk (Zn)  Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení kovů metodou ICP/MS-Quadrupole Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  Li  Mg  Mn  Mo  Ni  Pb  Se  Sb  Sn  Sr  Ti  Tl  U  V  Zn  AK18A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie metali metoda ICP/MS z analizatorem kwadrupolowym Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Lit (Li)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Nikiel (Ni)  Olow (Pb)  Selen (Se)  Antymon (Sb)  Cyna (Sn)  Stront (Sr)  Tytan (Ti)  Tal (Tl)  Uran (U)  Wanad (V)  Cynk (Zn)  Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni kovu metodou ICP/MS-Quadrupole Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  Li  Mg  Mn  Mo  Ni  Pb  Se  Sb  Sn  Sr  Ti  Tl  U  V  Zn  AK18A (CSN EN ISO 17294-1; CSN EN ISO 17294-2)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of metals by quadrupole ICP/MS Silver (Ag)  Aluminium (Al)  Arsenic (As)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Lithium (Li)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Nickel (Ni)  Lead (Pb)  Selenium (Se)  Antimony (Sb)  Tin (Sn)  Strontium (Sr)  Titanium (Ti)  Thallium (Tl)  Uranium (U)  Vanadium (V)  Zinc (Zn)  AK18A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 四极杆ICP/MS法测定金属 银（Ag）  铝（Al）  砷（As）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  锂（Li）  镁（Mg）  锰（Mn）  钼（Mo）  镍（Ni）  铅（Pb）  硒（Se）  锑（Sb）  锡（Sn）  锶（Sr）  钛（Ti）  铊（Tl）  铀（U）  钒（V）  锌（Zn）  AK18A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7ef9ac87a6135cd445bb9e1d","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"49","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie metali metodą ICP/MS z analizatorem kwadrupolowym","methodology_en":"Determination of metals by quadrupole ICP/MS","methodology_zh":"四极杆ICP/MS法测定金属","methodology_cs":"Stanovení kovů metodou ICP/MS-Quadrupole","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Uran (U)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Uranium (U)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"硒（Se）","range":""},{"name":"锑（Sb）","range":""},{"name":"锡（Sn）","range":""},{"name":"铀（U）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"Se","range":""},{"name":"Sb","range":""},{"name":"Sn","range":""},{"name":"U","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali metodą ICP/MS z analizatorem kwadrupolowym\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nSelen (Se)\nAntymon (Sb)\nCyna (Sn)\nUran (U)\nWanad (V)\nCynk (Zn)","reference":"AK18B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16171)","norm_bases":["AK18B","ČSN EN ISO 17294-1","ČSN EN ISO 17294-2","ČSN EN 16171"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie metali metodą ICP/MS z analizatorem kwadrupolowym Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Selen (Se)  Antymon (Sb)  Cyna (Sn)  Uran (U)  Wanad (V)  Cynk (Zn)  Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení kovů metodou ICP/MS-Quadrupole Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  Mg  Mn  Mo  Ni  P  Pb  Se  Sb  Sn  U  V  Zn  AK18B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16171) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie metali metoda ICP/MS z analizatorem kwadrupolowym Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Selen (Se)  Antymon (Sb)  Cyna (Sn)  Uran (U)  Wanad (V)  Cynk (Zn)  Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni kovu metodou ICP/MS-Quadrupole Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  Mg  Mn  Mo  Ni  P  Pb  Se  Sb  Sn  U  V  Zn  AK18B (CSN EN ISO 17294-1; CSN EN ISO 17294-2; CSN EN 16171)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of metals by quadrupole ICP/MS Silver (Ag)  Aluminium (Al)  Arsenic (As)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Selenium (Se)  Antimony (Sb)  Tin (Sn)  Uranium (U)  Vanadium (V)  Zinc (Zn)  AK18B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16171)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 四极杆ICP/MS法测定金属 银（Ag）  铝（Al）  砷（As）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  镁（Mg）  锰（Mn）  钼（Mo）  镍（Ni）  磷（P）  铅（Pb）  硒（Se）  锑（Sb）  锡（Sn）  铀（U）  钒（V）  锌（Zn）  AK18B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16171)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7c395f6ece271b59f03275b1","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"50","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie lotnych związków organicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych","methodology_en":"Determination of volatile organic compounds by GC/MSD and calculation of their sum from measured values","methodology_zh":"GC/MSD法测定挥发性有机物并由测量值计算其总和","methodology_cs":"Stanovení těkavých organických látek metodou GC/MSD a výpočet sumy těkavých organických látek z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie lotnych związków organicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych","reference":"AO02A (ČSN EN ISO 15680; ČSN 75 7550; ČSN EN ISO 10301)","norm_bases":["AO02A","ČSN EN ISO 15680","ČSN 75 7550","ČSN EN ISO 10301"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): Vinylchlorid, sirouhlík, dichlormethan, 1,1-dichloreten, c-1,2-dichlorethen, t-1,2-dichlorethen, trichlormethan, 1,2-dichlorethan, tetrachlormethan, benzen, trichloretylen, toluen, tetrachloretylen, ethylbenzen, styren, 1,3/1,4-xylen, 1,2-xylen, chlorbenzen, 2-chlortoluen, 4-chlortoluen, 1,2,4-trimetylbenzen, 1,3,5-trimethylbenzen, 1,3-dichlorbenzen, 1,4-dichlorbenzen, 1,2-dichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3- trichlorbenzen, 1,3,5-trichlorbenzen, naftalen, 2-metyl-naftalen, 1-metyl-naftalen, 1-chlor-naftalen, 2-chlor-naftalen, hexachlorbutadien, bromdichlormetan, dibromchlormetan, tribrommetan, izopropylbenzen, methyl-terc-butylether, hexachlorethan, aceton, ethyl acetát, tetrahydrofuran, diethyl eter, aliph. >C5-C8, aliph. >C8-C10.","note_en":"Determined analytes (analyte names as in the Czech original): Vinylchlorid, sirouhlík, dichlormethan, 1,1-dichloreten, c-1,2-dichlorethen, t-1,2-dichlorethen, trichlormethan, 1,2-dichlorethan, tetrachlormethan, benzen, trichloretylen, toluen, tetrachloretylen, ethylbenzen, styren, 1,3/1,4-xylen, 1,2-xylen, chlorbenzen, 2-chlortoluen, 4-chlortoluen, 1,2,4-trimetylbenzen, 1,3,5-trimethylbenzen, 1,3-dichlorbenzen, 1,4-dichlorbenzen, 1,2-dichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3- trichlorbenzen, 1,3,5-trichlorbenzen, naftalen, 2-metyl-naftalen, 1-metyl-naftalen, 1-chlor-naftalen, 2-chlor-naftalen, hexachlorbutadien, bromdichlormetan, dibromchlormetan, tribrommetan, izopropylbenzen, methyl-terc-butylether, hexachlorethan, aceton, ethyl acetát, tetrahydrofuran, diethyl eter, aliph. >C5-C8, aliph. >C8-C10.","note_zh":"测定的分析物（分析物名称同捷克语原文）：Vinylchlorid, sirouhlík, dichlormethan, 1,1-dichloreten, c-1,2-dichlorethen, t-1,2-dichlorethen, trichlormethan, 1,2-dichlorethan, tetrachlormethan, benzen, trichloretylen, toluen, tetrachloretylen, ethylbenzen, styren, 1,3/1,4-xylen, 1,2-xylen, chlorbenzen, 2-chlortoluen, 4-chlortoluen, 1,2,4-trimetylbenzen, 1,3,5-trimethylbenzen, 1,3-dichlorbenzen, 1,4-dichlorbenzen, 1,2-dichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3- trichlorbenzen, 1,3,5-trichlorbenzen, naftalen, 2-metyl-naftalen, 1-metyl-naftalen, 1-chlor-naftalen, 2-chlor-naftalen, hexachlorbutadien, bromdichlormetan, dibromchlormetan, tribrommetan, izopropylbenzen, methyl-terc-butylether, hexachlorethan, aceton, ethyl acetát, tetrahydrofuran, diethyl eter, aliph. >C5-C8, aliph. >C8-C10.","note_cs":"Vinylchlorid, sirouhlík, dichlormethan, 1,1-dichloreten, c-1,2-dichlorethen, t-1,2-dichlorethen, trichlormethan, 1,2-dichlorethan, tetrachlormethan, benzen, trichloretylen, toluen, tetrachloretylen, ethylbenzen, styren, 1,3/1,4-xylen, 1,2-xylen, chlorbenzen, 2-chlortoluen, 4-chlortoluen, 1,2,4-trimetylbenzen, 1,3,5-trimethylbenzen, 1,3-dichlorbenzen, 1,4-dichlorbenzen, 1,2-dichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3- trichlorbenzen, 1,3,5-trichlorbenzen, naftalen, 2-metyl-naftalen, 1-metyl-naftalen, 1-chlor-naftalen, 2-chlor-naftalen, hexachlorbutadien, bromdichlormetan, dibromchlormetan, tribrommetan, izopropylbenzen, methyl-terc-butylether, hexachlorethan, aceton, ethyl acetát, tetrahydrofuran, diethyl eter, aliph. >C5-C8, aliph. >C8-C10.","search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie lotnych związków organicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení těkavých organických látek metodou GC/MSD a výpočet sumy těkavých organických látek z naměřených hodnot AO02A (ČSN EN ISO 15680; ČSN 75 7550; ČSN EN ISO 10301) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie lotnych zwiazkow organicznych metoda GC/MSD i obliczenie ich sumy z wartosci zmierzonych Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni tekavych organickych latek metodou GC/MSD a vypocet sumy tekavych organickych latek z namerenych hodnot AO02A (CSN EN ISO 15680; CSN 75 7550; CSN EN ISO 10301)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of volatile organic compounds by GC/MSD and calculation of their sum from measured values AO02A (ČSN EN ISO 15680; ČSN 75 7550; ČSN EN ISO 10301)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 GC/MSD法测定挥发性有机物并由测量值计算其总和 AO02A (ČSN EN ISO 15680; ČSN 75 7550; ČSN EN ISO 10301)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ffc161327bb28c14611534eb","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"51","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady","methodology":"Oznaczanie lotnych związków organicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych","methodology_en":"Determination of volatile organic compounds by GC/MSD and calculation of their sum from measured values","methodology_zh":"GC/MSD法测定挥发性有机物并由测量值计算其总和","methodology_cs":"Stanovení těkavých organických látek metodou GC/MSD a výpočet sumy těkavých organických látek z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie lotnych związków organicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych","reference":"AO02B (EPA 8260; TNV 75 7552)","norm_bases":["AO02B","EPA 8260","TNV 75 7552"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): c-1,2-DCE, t-1,2-DCE, trichlormethan, 1,2-DCEt, benzen, tetrachlormethan, trichloretylen, toluen, tetrachloretylen, chlorbenzen, ethylbenzen, 1,3/1,4-X, 1,2-X, 2-chlortoluen, 4-chlortoluen, 1,4-DCB, 1,3-DCB, 1,2-DCB, 1,2,4-TCB, 1,2,3-TCB, 1,3,5-TCB, naftalen, hexachlorbutadien, aliph. >C5-C8, aliph. >C8-C10.","note_en":"Determined analytes (analyte names as in the Czech original): c-1,2-DCE, t-1,2-DCE, trichlormethan, 1,2-DCEt, benzen, tetrachlormethan, trichloretylen, toluen, tetrachloretylen, chlorbenzen, ethylbenzen, 1,3/1,4-X, 1,2-X, 2-chlortoluen, 4-chlortoluen, 1,4-DCB, 1,3-DCB, 1,2-DCB, 1,2,4-TCB, 1,2,3-TCB, 1,3,5-TCB, naftalen, hexachlorbutadien, aliph. >C5-C8, aliph. >C8-C10.","note_zh":"测定的分析物（分析物名称同捷克语原文）：c-1,2-DCE, t-1,2-DCE, trichlormethan, 1,2-DCEt, benzen, tetrachlormethan, trichloretylen, toluen, tetrachloretylen, chlorbenzen, ethylbenzen, 1,3/1,4-X, 1,2-X, 2-chlortoluen, 4-chlortoluen, 1,4-DCB, 1,3-DCB, 1,2-DCB, 1,2,4-TCB, 1,2,3-TCB, 1,3,5-TCB, naftalen, hexachlorbutadien, aliph. >C5-C8, aliph. >C8-C10.","note_cs":"c-1,2-DCE, t-1,2-DCE, trichlormethan, 1,2-DCEt, benzen, tetrachlormethan, trichloretylen, toluen, tetrachloretylen, chlorbenzen, ethylbenzen, 1,3/1,4-X, 1,2-X, 2-chlortoluen, 4-chlortoluen, 1,4-DCB, 1,3-DCB, 1,2-DCB, 1,2,4-TCB, 1,2,3-TCB, 1,3,5-TCB, naftalen, hexachlorbutadien, aliph. >C5-C8, aliph. >C8-C10.","search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe Oznaczanie lotnych związków organicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady Stanovení těkavých organických látek metodou GC/MSD a výpočet sumy těkavých organických látek z naměřených hodnot AO02B (EPA 8260; TNV 75 7552) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale Oznaczanie lotnych zwiazkow organicznych metoda GC/MSD i obliczenie ich sumy z wartosci zmierzonych Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady Stanoveni tekavych organickych latek metodou GC/MSD a vypocet sumy tekavych organickych latek z namerenych hodnot AO02B (EPA 8260; TNV 75 7552)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste Determination of volatile organic compounds by GC/MSD and calculation of their sum from measured values AO02B (EPA 8260; TNV 75 7552)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物 GC/MSD法测定挥发性有机物并由测量值计算其总和 AO02B (EPA 8260; TNV 75 7552)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cf488bfe2498c39dfbc43c04","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"52","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie polichlorowanych bifenyli (PCB) i pestycydów chloroorganicznych (OCP) metodą GC/MSD, ECD i obliczenie sum PCB i pestycydów z wartości zmierzonych","methodology_en":"Determination of polychlorinated biphenyls (PCB) and organochlorine pesticides (OCP) by GC/MSD, ECD and calculation of the sums of PCB and pesticides from measured values","methodology_zh":"GC/MSD、ECD法测定多氯联苯（PCB）和有机氯农药（OCP）并由测量值计算PCB和农药总和","methodology_cs":"Stanovení polychlorovaných bifenylů (PCB), organochlorových pesticidů (OCP) metodou GC/MSD, ECD a výpočet sum PCB a pesticidů z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie polichlorowanych bifenyli (PCB) i pestycydów chloroorganicznych (OCP) metodą GC/MSD, ECD i obliczenie sum PCB i pestycydów z wartości zmierzonych","reference":"AO03A (ČSN EN ISO 6468)","norm_bases":["AO03A","ČSN EN ISO 6468"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, α-HCH, HCB, β-HCH, γ-HCH, δ-HCH, ε-HCH, o,p‘-DDE, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, heptachlor, methoxychlor, α-endosulfan, β-endosulfan, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-209, musk keton, musk xylene, galaxolide, tonalide-AHTN, DEHF, pentachlorbenzen, endrin, dieldrin, aldrin, isodrin, 1,2,4,5-tetrachlorbenzen.","note_en":"Determined analytes (analyte names as in the Czech original): PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, α-HCH, HCB, β-HCH, γ-HCH, δ-HCH, ε-HCH, o,p‘-DDE, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, heptachlor, methoxychlor, α-endosulfan, β-endosulfan, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-209, musk keton, musk xylene, galaxolide, tonalide-AHTN, DEHF, pentachlorbenzen, endrin, dieldrin, aldrin, isodrin, 1,2,4,5-tetrachlorbenzen.","note_zh":"测定的分析物（分析物名称同捷克语原文）：PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, α-HCH, HCB, β-HCH, γ-HCH, δ-HCH, ε-HCH, o,p‘-DDE, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, heptachlor, methoxychlor, α-endosulfan, β-endosulfan, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-209, musk keton, musk xylene, galaxolide, tonalide-AHTN, DEHF, pentachlorbenzen, endrin, dieldrin, aldrin, isodrin, 1,2,4,5-tetrachlorbenzen.","note_cs":"PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, α-HCH, HCB, β-HCH, γ-HCH, δ-HCH, ε-HCH, o,p‘-DDE, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, heptachlor, methoxychlor, α-endosulfan, β-endosulfan, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-209, musk keton, musk xylene, galaxolide, tonalide-AHTN, DEHF, pentachlorbenzen, endrin, dieldrin, aldrin, isodrin, 1,2,4,5-tetrachlorbenzen.","search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie polichlorowanych bifenyli (PCB) i pestycydów chloroorganicznych (OCP) metodą GC/MSD, ECD i obliczenie sum PCB i pestycydów z wartości zmierzonych Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení polychlorovaných bifenylů (PCB), organochlorových pesticidů (OCP) metodou GC/MSD, ECD a výpočet sum PCB a pesticidů z naměřených hodnot AO03A (ČSN EN ISO 6468) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie polichlorowanych bifenyli (PCB) i pestycydow chloroorganicznych (OCP) metoda GC/MSD, ECD i obliczenie sum PCB i pestycydow z wartosci zmierzonych Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni polychlorovanych bifenylu (PCB), organochlorovych pesticidu (OCP) metodou GC/MSD, ECD a vypocet sum PCB a pesticidu z namerenych hodnot AO03A (CSN EN ISO 6468)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of polychlorinated biphenyls (PCB) and organochlorine pesticides (OCP) by GC/MSD, ECD and calculation of the sums of PCB and pesticides from measured values AO03A (ČSN EN ISO 6468)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 GC/MSD、ECD法测定多氯联苯（PCB）和有机氯农药（OCP）并由测量值计算PCB和农药总和 AO03A (ČSN EN ISO 6468)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"be820174c8ba97bd50f12a87","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"53","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady","methodology":"Oznaczanie polichlorowanych bifenyli (PCB) i pestycydów chloroorganicznych (OCP) metodą GC/MSD, ECD i obliczenie sum PCB i pestycydów z wartości zmierzonych","methodology_en":"Determination of polychlorinated biphenyls (PCB) and organochlorine pesticides (OCP) by GC/MSD, ECD and calculation of the sums of PCB and pesticides from measured values","methodology_zh":"GC/MSD、ECD法测定多氯联苯（PCB）和有机氯农药（OCP）并由测量值计算PCB和农药总和","methodology_cs":"Stanovení polychlorovaných bifenylů (PCB) a organochlorových pesticidů (OCP) metodou GC/MSD, ECD a výpočet sum PCB a pesticidů z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie polichlorowanych bifenyli (PCB) i pestycydów chloroorganicznych (OCP) metodą GC/MSD, ECD i obliczenie sum PCB i pestycydów z wartości zmierzonych","reference":"AO03B (EPA 8080; ČSN EN 16167)","norm_bases":["AO03B","EPA 8080","ČSN EN 16167"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, o,p‘-DDE, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, heptachlor, methoxychlor, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, chlorpyrifos, trifluralin, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, 1,2,4,5-tetrachlorbenzen, hexachlor- butadien (HCBD).","note_en":"Determined analytes (analyte names as in the Czech original): PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, o,p‘-DDE, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, heptachlor, methoxychlor, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, chlorpyrifos, trifluralin, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, 1,2,4,5-tetrachlorbenzen, hexachlor- butadien (HCBD).","note_zh":"测定的分析物（分析物名称同捷克语原文）：PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, o,p‘-DDE, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, heptachlor, methoxychlor, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, chlorpyrifos, trifluralin, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, 1,2,4,5-tetrachlorbenzen, hexachlor- butadien (HCBD).","note_cs":"PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, o,p‘-DDE, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, heptachlor, methoxychlor, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, chlorpyrifos, trifluralin, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, 1,2,4,5-tetrachlorbenzen, hexachlor- butadien (HCBD).","search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe Oznaczanie polichlorowanych bifenyli (PCB) i pestycydów chloroorganicznych (OCP) metodą GC/MSD, ECD i obliczenie sum PCB i pestycydów z wartości zmierzonych Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady Stanovení polychlorovaných bifenylů (PCB) a organochlorových pesticidů (OCP) metodou GC/MSD, ECD a výpočet sum PCB a pesticidů z naměřených hodnot AO03B (EPA 8080; ČSN EN 16167) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale Oznaczanie polichlorowanych bifenyli (PCB) i pestycydow chloroorganicznych (OCP) metoda GC/MSD, ECD i obliczenie sum PCB i pestycydow z wartosci zmierzonych Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady Stanoveni polychlorovanych bifenylu (PCB) a organochlorovych pesticidu (OCP) metodou GC/MSD, ECD a vypocet sum PCB a pesticidu z namerenych hodnot AO03B (EPA 8080; CSN EN 16167)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste Determination of polychlorinated biphenyls (PCB) and organochlorine pesticides (OCP) by GC/MSD, ECD and calculation of the sums of PCB and pesticides from measured values AO03B (EPA 8080; ČSN EN 16167)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物 GC/MSD、ECD法测定多氯联苯（PCB）和有机氯农药（OCP）并由测量值计算PCB和农药总和 AO03B (EPA 8080; ČSN EN 16167)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aed641dbf621d7cfa7fb662b","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"54","test_object":"Materiał zwierzęcy i roślinny","test_object_en":"Animal and plant material","test_object_zh":"动物和植物材料","test_object_cs":"Živočišný a rostlinný materiál","methodology":"Oznaczanie polichlorowanych bifenyli (PCB) i pestycydów chloroorganicznych (OCP) metodą GC/MSD, ECD i obliczenie sum PCB i pestycydów z wartości zmierzonych","methodology_en":"Determination of polychlorinated biphenyls (PCB) and organochlorine pesticides (OCP) by GC/MSD, ECD and calculation of the sums of PCB and pesticides from measured values","methodology_zh":"GC/MSD、ECD法测定多氯联苯（PCB）和有机氯农药（OCP）并由测量值计算PCB和农药总和","methodology_cs":"Stanovení polychlorovaných bifenylů (PCB) a organochlorových pesticidů (OCP) metodou GC/MSD, ECD a výpočet sum PCB a pesticidů z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie polichlorowanych bifenyli (PCB) i pestycydów chloroorganicznych (OCP) metodą GC/MSD, ECD i obliczenie sum PCB i pestycydów z wartości zmierzonych","reference":"AO03C (EPA 8080)","norm_bases":["AO03C","EPA 8080"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, o,p‘-DDE, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, heptachlor, methoxychlor, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, chlorpyrifos, trifluralin, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, 1,2,4,5-tetrachlorbenzen, hexachlor- butadien (HCBD).","note_en":"Determined analytes (analyte names as in the Czech original): PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, o,p‘-DDE, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, heptachlor, methoxychlor, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, chlorpyrifos, trifluralin, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, 1,2,4,5-tetrachlorbenzen, hexachlor- butadien (HCBD).","note_zh":"测定的分析物（分析物名称同捷克语原文）：PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, o,p‘-DDE, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, heptachlor, methoxychlor, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, chlorpyrifos, trifluralin, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, 1,2,4,5-tetrachlorbenzen, hexachlor- butadien (HCBD).","note_cs":"PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, o,p‘-DDE, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, heptachlor, methoxychlor, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, chlorpyrifos, trifluralin, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, 1,2,4,5-tetrachlorbenzen, hexachlor- butadien (HCBD).","search_text":"Materiał zwierzęcy i roślinny Oznaczanie polichlorowanych bifenyli (PCB) i pestycydów chloroorganicznych (OCP) metodą GC/MSD, ECD i obliczenie sum PCB i pestycydów z wartości zmierzonych Živočišný a rostlinný materiál Stanovení polychlorovaných bifenylů (PCB) a organochlorových pesticidů (OCP) metodou GC/MSD, ECD a výpočet sum PCB a pesticidů z naměřených hodnot AO03C (EPA 8080) Material zwierzecy i roslinny Oznaczanie polichlorowanych bifenyli (PCB) i pestycydow chloroorganicznych (OCP) metoda GC/MSD, ECD i obliczenie sum PCB i pestycydow z wartosci zmierzonych Zivocisny a rostlinny material Stanoveni polychlorovanych bifenylu (PCB) a organochlorovych pesticidu (OCP) metodou GC/MSD, ECD a vypocet sum PCB a pesticidu z namerenych hodnot AO03C (EPA 8080)","search_en":"Animal and plant material Determination of polychlorinated biphenyls (PCB) and organochlorine pesticides (OCP) by GC/MSD, ECD and calculation of the sums of PCB and pesticides from measured values AO03C (EPA 8080)","search_zh":"动物和植物材料 GC/MSD、ECD法测定多氯联苯（PCB）和有机氯农药（OCP）并由测量值计算PCB和农药总和 AO03C (EPA 8080)","categories":["environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5aa7952ec8268513856bba3c","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"55","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie fenoli i chlorofenoli metodą GC/MSD i obliczenie ich sum z wartości zmierzonych","methodology_en":"Determination of phenols and chlorophenols by GC/MSD and calculation of their sums from measured values","methodology_zh":"GC/MSD法测定酚类和氯酚并由测量值计算其总和","methodology_cs":"Stanovení fenolů a chlorfenolů metodou GC/MSD a výpočet sum fenolů a chlorfenolů z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fenoli i chlorofenoli metodą GC/MSD i obliczenie ich sum z wartości zmierzonych","reference":"AO04A (ČSN EN 12673)","norm_bases":["AO04A","ČSN EN 12673"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): Fenol, p-kresol, m-kresol, o-kresol, 2-CF, 3-CF, 4-CF, 2,6-DCF, 2,4+2,5-DCF, 3,5-DCF, 2,3-DCF, 3,4-DCF, 2,4,6-TCF, 2,3,6-TCF, 2,4,5-TCF, 2,3,5,6-TTCF, 2,3,4,6-TTCF, 2,3,4,5-TTCF, α-naftol, β-naftol, PCF, 4-chlor-3-methylfenol, 2,4-dimethylfenol, 4-n-nonylfenol, 4-terc.-oktylfenol, 4-n-oktylfenol, bisphenol A, nonylfenoly, tetrabrombisphenol-A, triclosan, 4-chlor-2-methylfenol, 2,6-di-tert-butylfenol (2,6-DTBP), 2,6-dimethylfenol (2,6-DMF), 2,4,6-tri-tert-butylfenol (2,4,6-TTBP), 4-(1,1-dimethylpropyl)-fenol, bisfenol F (BPF), bisfenol BP (BP-BP), bisfenol M (BPM), bisfenol P (BPP), bisfenol Z (BPZ), bisfenol TMC (BP-TMC).","note_en":"Determined analytes (analyte names as in the Czech original): Fenol, p-kresol, m-kresol, o-kresol, 2-CF, 3-CF, 4-CF, 2,6-DCF, 2,4+2,5-DCF, 3,5-DCF, 2,3-DCF, 3,4-DCF, 2,4,6-TCF, 2,3,6-TCF, 2,4,5-TCF, 2,3,5,6-TTCF, 2,3,4,6-TTCF, 2,3,4,5-TTCF, α-naftol, β-naftol, PCF, 4-chlor-3-methylfenol, 2,4-dimethylfenol, 4-n-nonylfenol, 4-terc.-oktylfenol, 4-n-oktylfenol, bisphenol A, nonylfenoly, tetrabrombisphenol-A, triclosan, 4-chlor-2-methylfenol, 2,6-di-tert-butylfenol (2,6-DTBP), 2,6-dimethylfenol (2,6-DMF), 2,4,6-tri-tert-butylfenol (2,4,6-TTBP), 4-(1,1-dimethylpropyl)-fenol, bisfenol F (BPF), bisfenol BP (BP-BP), bisfenol M (BPM), bisfenol P (BPP), bisfenol Z (BPZ), bisfenol TMC (BP-TMC).","note_zh":"测定的分析物（分析物名称同捷克语原文）：Fenol, p-kresol, m-kresol, o-kresol, 2-CF, 3-CF, 4-CF, 2,6-DCF, 2,4+2,5-DCF, 3,5-DCF, 2,3-DCF, 3,4-DCF, 2,4,6-TCF, 2,3,6-TCF, 2,4,5-TCF, 2,3,5,6-TTCF, 2,3,4,6-TTCF, 2,3,4,5-TTCF, α-naftol, β-naftol, PCF, 4-chlor-3-methylfenol, 2,4-dimethylfenol, 4-n-nonylfenol, 4-terc.-oktylfenol, 4-n-oktylfenol, bisphenol A, nonylfenoly, tetrabrombisphenol-A, triclosan, 4-chlor-2-methylfenol, 2,6-di-tert-butylfenol (2,6-DTBP), 2,6-dimethylfenol (2,6-DMF), 2,4,6-tri-tert-butylfenol (2,4,6-TTBP), 4-(1,1-dimethylpropyl)-fenol, bisfenol F (BPF), bisfenol BP (BP-BP), bisfenol M (BPM), bisfenol P (BPP), bisfenol Z (BPZ), bisfenol TMC (BP-TMC).","note_cs":"Fenol, p-kresol, m-kresol, o-kresol, 2-CF, 3-CF, 4-CF, 2,6-DCF, 2,4+2,5-DCF, 3,5-DCF, 2,3-DCF, 3,4-DCF, 2,4,6-TCF, 2,3,6-TCF, 2,4,5-TCF, 2,3,5,6-TTCF, 2,3,4,6-TTCF, 2,3,4,5-TTCF, α-naftol, β-naftol, PCF, 4-chlor-3-methylfenol, 2,4-dimethylfenol, 4-n-nonylfenol, 4-terc.-oktylfenol, 4-n-oktylfenol, bisphenol A, nonylfenoly, tetrabrombisphenol-A, triclosan, 4-chlor-2-methylfenol, 2,6-di-tert-butylfenol (2,6-DTBP), 2,6-dimethylfenol (2,6-DMF), 2,4,6-tri-tert-butylfenol (2,4,6-TTBP), 4-(1,1-dimethylpropyl)-fenol, bisfenol F (BPF), bisfenol BP (BP-BP), bisfenol M (BPM), bisfenol P (BPP), bisfenol Z (BPZ), bisfenol TMC (BP-TMC).","search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie fenoli i chlorofenoli metodą GC/MSD i obliczenie ich sum z wartości zmierzonych Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení fenolů a chlorfenolů metodou GC/MSD a výpočet sum fenolů a chlorfenolů z naměřených hodnot AO04A (ČSN EN 12673) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie fenoli i chlorofenoli metoda GC/MSD i obliczenie ich sum z wartosci zmierzonych Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni fenolu a chlorfenolu metodou GC/MSD a vypocet sum fenolu a chlorfenolu z namerenych hodnot AO04A (CSN EN 12673)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of phenols and chlorophenols by GC/MSD and calculation of their sums from measured values AO04A (ČSN EN 12673)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 GC/MSD法测定酚类和氯酚并由测量值计算其总和 AO04A (ČSN EN 12673)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"98a32f9000d33d4296649ccf","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"56","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, dializat z próbnika pasywnego","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, dialysate from a passive sampler","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器透析液","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, dialyzát z pasivního vzorkovače","methodology":"Oznaczanie fenoli i chlorofenoli metodą GC/MSD i obliczenie ich sum z wartości zmierzonych","methodology_en":"Determination of phenols and chlorophenols by GC/MSD and calculation of their sums from measured values","methodology_zh":"GC/MSD法测定酚类和氯酚并由测量值计算其总和","methodology_cs":"Stanovení fenolů a chlorfenolů metodou GC/MSD a výpočet sum fenolů a chlorfenolů z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fenoli i chlorofenoli metodą GC/MSD i obliczenie ich sum z wartości zmierzonych","reference":"AO04B (EPA 8041. A)","norm_bases":["AO04B","EPA 8041. A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): Fenol, p-kresol, m-kresol, o-kresol, 2-CF, 3-CF, 4-CF, 2,6-DCF, 2,4+2,5-DCF, 3,5-DCF, 2,3-DCF, 3,4-DCF, 2,4,6-TCF, 2,3,6-TCF, 2,4,5-TCF, 2,3,5,6-TTCF, 2,3,4,6-TTCF, 2,3,4,5-TTCF, α-naftol, β-naftol, PCF, 4-chlor-3-methylfenol, 2,4-dimethylfenol, 4-terc.-oktylfenol, 4-n-oktylfenol, bisphenol A, nonylfenoly, 4-n-nonylfenol, tetrabrombisphenol-A, triclosan, 4-chlor-2-methylfenol, 2,6-di-tert-butylfenol (2,6-DTBP), 2,6-dimethylfenol (2,6-DMF), 2,4,6-tri-tert-butylfenol (2,4,6-TTBP), 4-(1,1-dimethylpropyl)-fenol, bisfenol F (BPF), bisfenol BP (BP-BP), bisfenol M (BPM), bisfenol P (BPP), bisfenol Z (BPZ), bisfenol TMC (BP-TMC).","note_en":"Determined analytes (analyte names as in the Czech original): Fenol, p-kresol, m-kresol, o-kresol, 2-CF, 3-CF, 4-CF, 2,6-DCF, 2,4+2,5-DCF, 3,5-DCF, 2,3-DCF, 3,4-DCF, 2,4,6-TCF, 2,3,6-TCF, 2,4,5-TCF, 2,3,5,6-TTCF, 2,3,4,6-TTCF, 2,3,4,5-TTCF, α-naftol, β-naftol, PCF, 4-chlor-3-methylfenol, 2,4-dimethylfenol, 4-terc.-oktylfenol, 4-n-oktylfenol, bisphenol A, nonylfenoly, 4-n-nonylfenol, tetrabrombisphenol-A, triclosan, 4-chlor-2-methylfenol, 2,6-di-tert-butylfenol (2,6-DTBP), 2,6-dimethylfenol (2,6-DMF), 2,4,6-tri-tert-butylfenol (2,4,6-TTBP), 4-(1,1-dimethylpropyl)-fenol, bisfenol F (BPF), bisfenol BP (BP-BP), bisfenol M (BPM), bisfenol P (BPP), bisfenol Z (BPZ), bisfenol TMC (BP-TMC).","note_zh":"测定的分析物（分析物名称同捷克语原文）：Fenol, p-kresol, m-kresol, o-kresol, 2-CF, 3-CF, 4-CF, 2,6-DCF, 2,4+2,5-DCF, 3,5-DCF, 2,3-DCF, 3,4-DCF, 2,4,6-TCF, 2,3,6-TCF, 2,4,5-TCF, 2,3,5,6-TTCF, 2,3,4,6-TTCF, 2,3,4,5-TTCF, α-naftol, β-naftol, PCF, 4-chlor-3-methylfenol, 2,4-dimethylfenol, 4-terc.-oktylfenol, 4-n-oktylfenol, bisphenol A, nonylfenoly, 4-n-nonylfenol, tetrabrombisphenol-A, triclosan, 4-chlor-2-methylfenol, 2,6-di-tert-butylfenol (2,6-DTBP), 2,6-dimethylfenol (2,6-DMF), 2,4,6-tri-tert-butylfenol (2,4,6-TTBP), 4-(1,1-dimethylpropyl)-fenol, bisfenol F (BPF), bisfenol BP (BP-BP), bisfenol M (BPM), bisfenol P (BPP), bisfenol Z (BPZ), bisfenol TMC (BP-TMC).","note_cs":"Fenol, p-kresol, m-kresol, o-kresol, 2-CF, 3-CF, 4-CF, 2,6-DCF, 2,4+2,5-DCF, 3,5-DCF, 2,3-DCF, 3,4-DCF, 2,4,6-TCF, 2,3,6-TCF, 2,4,5-TCF, 2,3,5,6-TTCF, 2,3,4,6-TTCF, 2,3,4,5-TTCF, α-naftol, β-naftol, PCF, 4-chlor-3-methylfenol, 2,4-dimethylfenol, 4-terc.-oktylfenol, 4-n-oktylfenol, bisphenol A, nonylfenoly, 4-n-nonylfenol, tetrabrombisphenol-A, triclosan, 4-chlor-2-methylfenol, 2,6-di-tert-butylfenol (2,6-DTBP), 2,6-dimethylfenol (2,6-DMF), 2,4,6-tri-tert-butylfenol (2,4,6-TTBP), 4-(1,1-dimethylpropyl)-fenol, bisfenol F (BPF), bisfenol BP (BP-BP), bisfenol M (BPM), bisfenol P (BPP), bisfenol Z (BPZ), bisfenol TMC (BP-TMC).","search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, dializat z próbnika pasywnego Oznaczanie fenoli i chlorofenoli metodą GC/MSD i obliczenie ich sum z wartości zmierzonych Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, dialyzát z pasivního vzorkovače Stanovení fenolů a chlorfenolů metodou GC/MSD a výpočet sum fenolů a chlorfenolů z naměřených hodnot AO04B (EPA 8041. A) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale, dializat z probnika pasywnego Oznaczanie fenoli i chlorofenoli metoda GC/MSD i obliczenie ich sum z wartosci zmierzonych Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady, dialyzat z pasivniho vzorkovace Stanoveni fenolu a chlorfenolu metodou GC/MSD a vypocet sum fenolu a chlorfenolu z namerenych hodnot AO04B (EPA 8041. A)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, dialysate from a passive sampler Determination of phenols and chlorophenols by GC/MSD and calculation of their sums from measured values AO04B (EPA 8041. A)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器透析液 GC/MSD法测定酚类和氯酚并由测量值计算其总和 AO04B (EPA 8041. A)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e3a8148ff73a707ef11303fb","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"57","test_object":"Materiał zwierzęcy i roślinny","test_object_en":"Animal and plant material","test_object_zh":"动物和植物材料","test_object_cs":"Živočišný a rostlinný materiál","methodology":"Oznaczanie fenoli i chlorofenoli metodą GC/MSD i obliczenie ich sum z wartości zmierzonych","methodology_en":"Determination of phenols and chlorophenols by GC/MSD and calculation of their sums from measured values","methodology_zh":"GC/MSD法测定酚类和氯酚并由测量值计算其总和","methodology_cs":"Stanovení fenolů a chlorfenolů metodou GC/MSD a výpočet sum fenolů a chlorfenolů z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fenoli i chlorofenoli metodą GC/MSD i obliczenie ich sum z wartości zmierzonych","reference":"AO04C (EPA 8041.A)","norm_bases":["AO04C","EPA 8041.A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): Fenol, p-kresol, m-kresol, o-kresol, 2-CF, 3-CF, 4-CF, 2,6-DCF, 2,4+2,5-DCF, 3,5-DCF, 2,3-DCF, 3,4-DCF, 2,4,6-TCF, 2,3,6-TCF, 2,4,5-TCF, 2,3,5,6-TTCF, 2,3,4,6-TTCF, 2,3,4,5-TTCF, α-naftol, β-naftol, PCF, 4-chlor-3-methylfenol, 2,4-dimethylfenol, 4-terc.-oktylfenol, 4-n-oktylfenol, bisphenol A, nonylfenoly, 4-n-nonylfenol, tetrabrombisphenol-A, triclosan, 4-chlor-2-methylfenol, 2,6-di-tert-butylfenol (2,6-DTBP), 2,6-dimethylfenol (2,6-DMF), 2,4,6-tri-tert-butylfenol (2,4,6-TTBP), 4-(1,1-dimethylpropyl)-fenolbisfenol F (BPF), bisfenol BP (BP-BP), bisfenol M (BPM), bisfenol P (BPP), bisfenol Z (BPZ), bisfenol TMC (BP-TMC).","note_en":"Determined analytes (analyte names as in the Czech original): Fenol, p-kresol, m-kresol, o-kresol, 2-CF, 3-CF, 4-CF, 2,6-DCF, 2,4+2,5-DCF, 3,5-DCF, 2,3-DCF, 3,4-DCF, 2,4,6-TCF, 2,3,6-TCF, 2,4,5-TCF, 2,3,5,6-TTCF, 2,3,4,6-TTCF, 2,3,4,5-TTCF, α-naftol, β-naftol, PCF, 4-chlor-3-methylfenol, 2,4-dimethylfenol, 4-terc.-oktylfenol, 4-n-oktylfenol, bisphenol A, nonylfenoly, 4-n-nonylfenol, tetrabrombisphenol-A, triclosan, 4-chlor-2-methylfenol, 2,6-di-tert-butylfenol (2,6-DTBP), 2,6-dimethylfenol (2,6-DMF), 2,4,6-tri-tert-butylfenol (2,4,6-TTBP), 4-(1,1-dimethylpropyl)-fenolbisfenol F (BPF), bisfenol BP (BP-BP), bisfenol M (BPM), bisfenol P (BPP), bisfenol Z (BPZ), bisfenol TMC (BP-TMC).","note_zh":"测定的分析物（分析物名称同捷克语原文）：Fenol, p-kresol, m-kresol, o-kresol, 2-CF, 3-CF, 4-CF, 2,6-DCF, 2,4+2,5-DCF, 3,5-DCF, 2,3-DCF, 3,4-DCF, 2,4,6-TCF, 2,3,6-TCF, 2,4,5-TCF, 2,3,5,6-TTCF, 2,3,4,6-TTCF, 2,3,4,5-TTCF, α-naftol, β-naftol, PCF, 4-chlor-3-methylfenol, 2,4-dimethylfenol, 4-terc.-oktylfenol, 4-n-oktylfenol, bisphenol A, nonylfenoly, 4-n-nonylfenol, tetrabrombisphenol-A, triclosan, 4-chlor-2-methylfenol, 2,6-di-tert-butylfenol (2,6-DTBP), 2,6-dimethylfenol (2,6-DMF), 2,4,6-tri-tert-butylfenol (2,4,6-TTBP), 4-(1,1-dimethylpropyl)-fenolbisfenol F (BPF), bisfenol BP (BP-BP), bisfenol M (BPM), bisfenol P (BPP), bisfenol Z (BPZ), bisfenol TMC (BP-TMC).","note_cs":"Fenol, p-kresol, m-kresol, o-kresol, 2-CF, 3-CF, 4-CF, 2,6-DCF, 2,4+2,5-DCF, 3,5-DCF, 2,3-DCF, 3,4-DCF, 2,4,6-TCF, 2,3,6-TCF, 2,4,5-TCF, 2,3,5,6-TTCF, 2,3,4,6-TTCF, 2,3,4,5-TTCF, α-naftol, β-naftol, PCF, 4-chlor-3-methylfenol, 2,4-dimethylfenol, 4-terc.-oktylfenol, 4-n-oktylfenol, bisphenol A, nonylfenoly, 4-n-nonylfenol, tetrabrombisphenol-A, triclosan, 4-chlor-2-methylfenol, 2,6-di-tert-butylfenol (2,6-DTBP), 2,6-dimethylfenol (2,6-DMF), 2,4,6-tri-tert-butylfenol (2,4,6-TTBP), 4-(1,1-dimethylpropyl)-fenolbisfenol F (BPF), bisfenol BP (BP-BP), bisfenol M (BPM), bisfenol P (BPP), bisfenol Z (BPZ), bisfenol TMC (BP-TMC).","search_text":"Materiał zwierzęcy i roślinny Oznaczanie fenoli i chlorofenoli metodą GC/MSD i obliczenie ich sum z wartości zmierzonych Živočišný a rostlinný materiál Stanovení fenolů a chlorfenolů metodou GC/MSD a výpočet sum fenolů a chlorfenolů z naměřených hodnot AO04C (EPA 8041.A) Material zwierzecy i roslinny Oznaczanie fenoli i chlorofenoli metoda GC/MSD i obliczenie ich sum z wartosci zmierzonych Zivocisny a rostlinny material Stanoveni fenolu a chlorfenolu metodou GC/MSD a vypocet sum fenolu a chlorfenolu z namerenych hodnot AO04C (EPA 8041.A)","search_en":"Animal and plant material Determination of phenols and chlorophenols by GC/MSD and calculation of their sums from measured values AO04C (EPA 8041.A)","search_zh":"动物和植物材料 GC/MSD法测定酚类和氯酚并由测量值计算其总和 AO04C (EPA 8041.A)","categories":["environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f6935009e65284db36d46b3d","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"58","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FD i obliczenie ich sumy z wartości zmierzonych","methodology_en":"Determination of polycyclic aromatic hydrocarbons by HPLC/FD and calculation of their sum from measured values","methodology_zh":"HPLC/FD法测定多环芳烃并由测量值计算其总和","methodology_cs":"Stanovení polycyklických aromatických uhlovodíků metodou HPLC/FD a výpočet sumy polycyklických aromatických uhlovodíků z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FD i obliczenie ich sumy z wartości zmierzonych","reference":"AO05A (ČSN EN ISO 17993 ČSN 75 7554)","norm_bases":["AO05A","ČSN EN ISO 17993","ČSN 75 7554"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): Naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren","note_en":"Determined analytes (analyte names as in the Czech original): Naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren","note_zh":"测定的分析物（分析物名称同捷克语原文）：Naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren","note_cs":"Naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren","search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FD i obliczenie ich sumy z wartości zmierzonych Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení polycyklických aromatických uhlovodíků metodou HPLC/FD a výpočet sumy polycyklických aromatických uhlovodíků z naměřených hodnot AO05A (ČSN EN ISO 17993 ČSN 75 7554) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie wielopierscieniowych weglowodorow aromatycznych metoda HPLC/FD i obliczenie ich sumy z wartosci zmierzonych Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni polycyklickych aromatickych uhlovodiku metodou HPLC/FD a vypocet sumy polycyklickych aromatickych uhlovodiku z namerenych hodnot AO05A (CSN EN ISO 17993 CSN 75 7554)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of polycyclic aromatic hydrocarbons by HPLC/FD and calculation of their sum from measured values AO05A (ČSN EN ISO 17993 ČSN 75 7554)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 HPLC/FD法测定多环芳烃并由测量值计算其总和 AO05A (ČSN EN ISO 17993 ČSN 75 7554)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"67fd7870c0b56d7637385f3a","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"59","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FD i obliczenie ich sumy z wartości zmierzonych","methodology_en":"Determination of polycyclic aromatic hydrocarbons by HPLC/FD and calculation of their sum from measured values","methodology_zh":"HPLC/FD法测定多环芳烃并由测量值计算其总和","methodology_cs":"Stanovení polycyklických aromatických uhlovodíků metodou HPLC/FD a výpočet sumy polycyklických aromatických uhlovodíků z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FD i obliczenie ich sumy z wartości zmierzonych","reference":"AO05B (ČSN EN 16181; EPA 8310)","norm_bases":["AO05B","ČSN EN 16181","EPA 8310"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): Naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren","note_en":"Determined analytes (analyte names as in the Czech original): Naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren","note_zh":"测定的分析物（分析物名称同捷克语原文）：Naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren","note_cs":"Naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren","search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FD i obliczenie ich sumy z wartości zmierzonych Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady Stanovení polycyklických aromatických uhlovodíků metodou HPLC/FD a výpočet sumy polycyklických aromatických uhlovodíků z naměřených hodnot AO05B (ČSN EN 16181; EPA 8310) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale Oznaczanie wielopierscieniowych weglowodorow aromatycznych metoda HPLC/FD i obliczenie ich sumy z wartosci zmierzonych Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady Stanoveni polycyklickych aromatickych uhlovodiku metodou HPLC/FD a vypocet sumy polycyklickych aromatickych uhlovodiku z namerenych hodnot AO05B (CSN EN 16181; EPA 8310)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste Determination of polycyclic aromatic hydrocarbons by HPLC/FD and calculation of their sum from measured values AO05B (ČSN EN 16181; EPA 8310)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物 HPLC/FD法测定多环芳烃并由测量值计算其总和 AO05B (ČSN EN 16181; EPA 8310)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5747fd33ad1ef48f76ccf5fc","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"60","test_object":"Materiał zwierzęcy i roślinny","test_object_en":"Animal and plant material","test_object_zh":"动物和植物材料","test_object_cs":"Živočišný a rostlinný materiál","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FD i obliczenie ich sumy z wartości zmierzonych","methodology_en":"Determination of polycyclic aromatic hydrocarbons by HPLC/FD and calculation of their sum from measured values","methodology_zh":"HPLC/FD法测定多环芳烃并由测量值计算其总和","methodology_cs":"Stanovení polycyklických aromatických uhlovodíků metodou HPLC/FD a výpočet sumy polycyklických aromatických uhlovodíků z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FD i obliczenie ich sumy z wartości zmierzonych","reference":"AO05C (EPA 8310)","norm_bases":["AO05C","EPA 8310"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): Naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren","note_en":"Determined analytes (analyte names as in the Czech original): Naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren","note_zh":"测定的分析物（分析物名称同捷克语原文）：Naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren","note_cs":"Naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren","search_text":"Materiał zwierzęcy i roślinny Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FD i obliczenie ich sumy z wartości zmierzonych Živočišný a rostlinný materiál Stanovení polycyklických aromatických uhlovodíků metodou HPLC/FD a výpočet sumy polycyklických aromatických uhlovodíků z naměřených hodnot AO05C (EPA 8310) Material zwierzecy i roslinny Oznaczanie wielopierscieniowych weglowodorow aromatycznych metoda HPLC/FD i obliczenie ich sumy z wartosci zmierzonych Zivocisny a rostlinny material Stanoveni polycyklickych aromatickych uhlovodiku metodou HPLC/FD a vypocet sumy polycyklickych aromatickych uhlovodiku z namerenych hodnot AO05C (EPA 8310)","search_en":"Animal and plant material Determination of polycyclic aromatic hydrocarbons by HPLC/FD and calculation of their sum from measured values AO05C (EPA 8310)","search_zh":"动物和植物材料 HPLC/FD法测定多环芳烃并由测量值计算其总和 AO05C (EPA 8310)","categories":["environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c82cafac0caf917e00b38d4a","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"61","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody technologiczne i morskie, wyciągi","test_object_en":"Drinking, surface, ground, waste, process and sea water, leachates","test_object_zh":"饮用水、地表水、地下水、废水、工艺用水和海水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní, technologické a mořské, výluhy","methodology":"Oznaczanie pestycydów azotowych i fosforowych metodą GC/MSD i obliczenie sumy pestycydów z wartości zmierzonych","methodology_en":"Determination of N and P pesticides by GC/MSD and calculation of the sum of pesticides from measured values","methodology_zh":"GC/MSD法测定含氮和含磷农药并由测量值计算农药总和","methodology_cs":"Stanovení N a P pesticidů metodou GC/MSD a výpočet sumy pesticidů z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pestycydów azotowych i fosforowych metodą GC/MSD i obliczenie sumy pestycydów z wartości zmierzonych","reference":"AO06A (ČSN EN ISO 10695)","norm_bases":["AO06A","ČSN EN ISO 10695"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): Desisopropylatrazin, desethylatrazin, simazin, atrazin, propazin, terbuthylazin, sebuthylazin, ametryn, prometryn, terbutryn, cyanazin, desmetryn, trifluralin, acetochlor, alachlor, metolachlor, matazachlor, propachlor, pendimethalin, lenacil, hexazinon, chlorpyrifos, chlorpyrifos-methyl, chlorfenvinfos, parathion, dichlobenil, dimethoate, diazinon, naftalen, bis(2-diethylhexyl)ftalát (DEHF), dimethachlor, metribuzin, fenpropidin, fenpropimorph, irgarol, quinoxyfen (chinoxyfen), picolinafen, malathion, parathion-methyl, parathion-ethyl, DEET, triclosan, triethylphosphate (TEP), triisobuthylphospate (TiBP), tributhylphospate (TBP), triphenylphospate (TPP), tris(2-chloroethyl)-phosphate (TCEP), tris(2-butoxyethyl)phosphate (TBEP), tris(1-chloro-2-propyl)phosphate (TCPP), biphenyl, fenitrothion, fenthion, flusilazol, metalaxyl, dichlorvos, aclonifen, bifenox, dicloran.","note_en":"Determined analytes (analyte names as in the Czech original): Desisopropylatrazin, desethylatrazin, simazin, atrazin, propazin, terbuthylazin, sebuthylazin, ametryn, prometryn, terbutryn, cyanazin, desmetryn, trifluralin, acetochlor, alachlor, metolachlor, matazachlor, propachlor, pendimethalin, lenacil, hexazinon, chlorpyrifos, chlorpyrifos-methyl, chlorfenvinfos, parathion, dichlobenil, dimethoate, diazinon, naftalen, bis(2-diethylhexyl)ftalát (DEHF), dimethachlor, metribuzin, fenpropidin, fenpropimorph, irgarol, quinoxyfen (chinoxyfen), picolinafen, malathion, parathion-methyl, parathion-ethyl, DEET, triclosan, triethylphosphate (TEP), triisobuthylphospate (TiBP), tributhylphospate (TBP), triphenylphospate (TPP), tris(2-chloroethyl)-phosphate (TCEP), tris(2-butoxyethyl)phosphate (TBEP), tris(1-chloro-2-propyl)phosphate (TCPP), biphenyl, fenitrothion, fenthion, flusilazol, metalaxyl, dichlorvos, aclonifen, bifenox, dicloran.","note_zh":"测定的分析物（分析物名称同捷克语原文）：Desisopropylatrazin, desethylatrazin, simazin, atrazin, propazin, terbuthylazin, sebuthylazin, ametryn, prometryn, terbutryn, cyanazin, desmetryn, trifluralin, acetochlor, alachlor, metolachlor, matazachlor, propachlor, pendimethalin, lenacil, hexazinon, chlorpyrifos, chlorpyrifos-methyl, chlorfenvinfos, parathion, dichlobenil, dimethoate, diazinon, naftalen, bis(2-diethylhexyl)ftalát (DEHF), dimethachlor, metribuzin, fenpropidin, fenpropimorph, irgarol, quinoxyfen (chinoxyfen), picolinafen, malathion, parathion-methyl, parathion-ethyl, DEET, triclosan, triethylphosphate (TEP), triisobuthylphospate (TiBP), tributhylphospate (TBP), triphenylphospate (TPP), tris(2-chloroethyl)-phosphate (TCEP), tris(2-butoxyethyl)phosphate (TBEP), tris(1-chloro-2-propyl)phosphate (TCPP), biphenyl, fenitrothion, fenthion, flusilazol, metalaxyl, dichlorvos, aclonifen, bifenox, dicloran.","note_cs":"Desisopropylatrazin, desethylatrazin, simazin, atrazin, propazin, terbuthylazin, sebuthylazin, ametryn, prometryn, terbutryn, cyanazin, desmetryn, trifluralin, acetochlor, alachlor, metolachlor, matazachlor, propachlor, pendimethalin, lenacil, hexazinon, chlorpyrifos, chlorpyrifos-methyl, chlorfenvinfos, parathion, dichlobenil, dimethoate, diazinon, naftalen, bis(2-diethylhexyl)ftalát (DEHF), dimethachlor, metribuzin, fenpropidin, fenpropimorph, irgarol, quinoxyfen (chinoxyfen), picolinafen, malathion, parathion-methyl, parathion-ethyl, DEET, triclosan, triethylphosphate (TEP), triisobuthylphospate (TiBP), tributhylphospate (TBP), triphenylphospate (TPP), tris(2-chloroethyl)-phosphate (TCEP), tris(2-butoxyethyl)phosphate (TBEP), tris(1-chloro-2-propyl)phosphate (TCPP), biphenyl, fenitrothion, fenthion, flusilazol, metalaxyl, dichlorvos, aclonifen, bifenox, dicloran.","search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody technologiczne i morskie, wyciągi Oznaczanie pestycydów azotowych i fosforowych metodą GC/MSD i obliczenie sumy pestycydów z wartości zmierzonych Vody pitné, povrchové, podzemní, odpadní, technologické a mořské, výluhy Stanovení N a P pesticidů metodou GC/MSD a výpočet sumy pesticidů z naměřených hodnot AO06A (ČSN EN ISO 10695) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wody technologiczne i morskie, wyciagi Oznaczanie pestycydow azotowych i fosforowych metoda GC/MSD i obliczenie sumy pestycydow z wartosci zmierzonych Vody pitne, povrchove, podzemni, odpadni, technologicke a morske, vyluhy Stanoveni N a P pesticidu metodou GC/MSD a vypocet sumy pesticidu z namerenych hodnot AO06A (CSN EN ISO 10695)","search_en":"Drinking, surface, ground, waste, process and sea water, leachates Determination of N and P pesticides by GC/MSD and calculation of the sum of pesticides from measured values AO06A (ČSN EN ISO 10695)","search_zh":"饮用水、地表水、地下水、废水、工艺用水和海水、浸出液 GC/MSD法测定含氮和含磷农药并由测量值计算农药总和 AO06A (ČSN EN ISO 10695)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0153a57612a2e7bd9c30fca7","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"62","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody technologiczne i morskie, wyciągi","test_object_en":"Drinking, surface, ground, waste, process and sea water, leachates","test_object_zh":"饮用水、地表水、地下水、废水、工艺用水和海水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické a mořské, výluhy","methodology":"Oznaczanie nitrozwiązków aromatycznych i anilin metodą GC/MSD i obliczenie ich sum z wartości zmierzonych","methodology_en":"Determination of nitroaromatics and anilines by GC/MSD and calculation of their sums from measured values","methodology_zh":"GC/MSD法测定硝基芳烃和苯胺类并由测量值计算其总和","methodology_cs":"Stanovení nitroaromátů a anilinů metodou GC/MSD a výpočet sum nitroaromátů a anilinů z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie nitrozwiązków aromatycznych i anilin metodą GC/MSD i obliczenie ich sum z wartości zmierzonych","reference":"AO09A (EPA 8270; EPA 609)","norm_bases":["AO09A","EPA 8270","EPA 609"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): Nitrobenzen, 2-nitrotoluen, 3-nitrotoluen, 4-nitrotoluen, 2,4-dinitrotoluen, 2,6- dinitrotoluen, 1-chlor-3-nitrobenzen, 1-chlor-4-nitrobenzen, 1-chlor-2-nitrobenzen, 1-chlor-2,4-dinitrobenzen, 1,4-dichlor-2-dinitrobenzen, 2,4-dichlor-nitrobenzen, 1,3-dinitrobenzen, 1,2- dinitrobenzen, anilin, N-ethylanilin, N,N-diethylanilin, trimethylanilin, 2,4-dichloranilin, 3,4-dichloranilin, 2-ethylanilin, 2,5-dichlortoluen, 2-chloranilin, 3 ,4 (suma 3 i 4)-chloranilin, 4-chlor-2-nitrotoluen, 2-chlor-4-nitrotoluen, 1,2-dichlor-4-nitrobenzen, 1,2-dichlor-3-nitrobenzen, 1-chlornaftalen, 4-chlor-2-nitroanilin, bis(1,3-dichlor-2-propyl)ether, bis(2,3-dichlor-1-propyl)ether, 1,3-dichlor-2-propyl-2´,3´-dichlor-1´-propylether, TCPE, 2-chlornaftalen, 3-chloranilin, 4-chloranilin, benzidine, 3,3´-dichlorobenzidine, difenylamin, pentachloroanilin.","note_en":"Determined analytes (analyte names as in the Czech original): Nitrobenzen, 2-nitrotoluen, 3-nitrotoluen, 4-nitrotoluen, 2,4-dinitrotoluen, 2,6- dinitrotoluen, 1-chlor-3-nitrobenzen, 1-chlor-4-nitrobenzen, 1-chlor-2-nitrobenzen, 1-chlor-2,4-dinitrobenzen, 1,4-dichlor-2-dinitrobenzen, 2,4-dichlor-nitrobenzen, 1,3-dinitrobenzen, 1,2- dinitrobenzen, anilin, N-ethylanilin, N,N-diethylanilin, trimethylanilin, 2,4-dichloranilin, 3,4-dichloranilin, 2-ethylanilin, 2,5-dichlortoluen, 2-chloranilin, 3 ,4 (sum of 3 and 4)-chloranilin, 4-chlor-2-nitrotoluen, 2-chlor-4-nitrotoluen, 1,2-dichlor-4-nitrobenzen, 1,2-dichlor-3-nitrobenzen, 1-chlornaftalen, 4-chlor-2-nitroanilin, bis(1,3-dichlor-2-propyl)ether, bis(2,3-dichlor-1-propyl)ether, 1,3-dichlor-2-propyl-2´,3´-dichlor-1´-propylether, TCPE, 2-chlornaftalen, 3-chloranilin, 4-chloranilin, benzidine, 3,3´-dichlorobenzidine, difenylamin, pentachloroanilin.","note_zh":"测定的分析物（分析物名称同捷克语原文）：Nitrobenzen, 2-nitrotoluen, 3-nitrotoluen, 4-nitrotoluen, 2,4-dinitrotoluen, 2,6- dinitrotoluen, 1-chlor-3-nitrobenzen, 1-chlor-4-nitrobenzen, 1-chlor-2-nitrobenzen, 1-chlor-2,4-dinitrobenzen, 1,4-dichlor-2-dinitrobenzen, 2,4-dichlor-nitrobenzen, 1,3-dinitrobenzen, 1,2- dinitrobenzen, anilin, N-ethylanilin, N,N-diethylanilin, trimethylanilin, 2,4-dichloranilin, 3,4-dichloranilin, 2-ethylanilin, 2,5-dichlortoluen, 2-chloranilin, 3 ,4 (sum of 3 and 4)-chloranilin, 4-chlor-2-nitrotoluen, 2-chlor-4-nitrotoluen, 1,2-dichlor-4-nitrobenzen, 1,2-dichlor-3-nitrobenzen, 1-chlornaftalen, 4-chlor-2-nitroanilin, bis(1,3-dichlor-2-propyl)ether, bis(2,3-dichlor-1-propyl)ether, 1,3-dichlor-2-propyl-2´,3´-dichlor-1´-propylether, TCPE, 2-chlornaftalen, 3-chloranilin, 4-chloranilin, benzidine, 3,3´-dichlorobenzidine, difenylamin, pentachloroanilin.","note_cs":"Nitrobenzen, 2-nitrotoluen, 3-nitrotoluen, 4-nitrotoluen, 2,4-dinitrotoluen, 2,6- dinitrotoluen, 1-chlor-3-nitrobenzen, 1-chlor-4-nitrobenzen, 1-chlor-2-nitrobenzen, 1-chlor-2,4-dinitrobenzen, 1,4-dichlor-2-dinitrobenzen, 2,4-dichlor-nitrobenzen, 1,3-dinitrobenzen, 1,2- dinitrobenzen, anilin, N-ethylanilin, N,N-diethylanilin, trimethylanilin, 2,4-dichloranilin, 3,4-dichloranilin, 2-ethylanilin, 2,5-dichlortoluen, 2-chloranilin, 3 ,4 (suma 3 a 4)-chloranilin, 4-chlor-2-nitrotoluen, 2-chlor-4-nitrotoluen, 1,2-dichlor-4-nitrobenzen, 1,2-dichlor-3-nitrobenzen, 1-chlornaftalen, 4-chlor-2-nitroanilin, bis(1,3-dichlor-2-propyl)ether, bis(2,3-dichlor-1-propyl)ether, 1,3-dichlor-2-propyl-2´,3´-dichlor-1´-propylether, TCPE, 2-chlornaftalen, 3-chloranilin, 4-chloranilin, benzidine, 3,3´-dichlorobenzidine, difenylamin, pentachloroanilin.","search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody technologiczne i morskie, wyciągi Oznaczanie nitrozwiązków aromatycznych i anilin metodą GC/MSD i obliczenie ich sum z wartości zmierzonych Vody pitné, povrchové, podzemní, odpadní a technologické a mořské, výluhy Stanovení nitroaromátů a anilinů metodou GC/MSD a výpočet sum nitroaromátů a anilinů z naměřených hodnot AO09A (EPA 8270; EPA 609) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wody technologiczne i morskie, wyciagi Oznaczanie nitrozwiazkow aromatycznych i anilin metoda GC/MSD i obliczenie ich sum z wartosci zmierzonych Vody pitne, povrchove, podzemni, odpadni a technologicke a morske, vyluhy Stanoveni nitroaromatu a anilinu metodou GC/MSD a vypocet sum nitroaromatu a anilinu z namerenych hodnot AO09A (EPA 8270; EPA 609)","search_en":"Drinking, surface, ground, waste, process and sea water, leachates Determination of nitroaromatics and anilines by GC/MSD and calculation of their sums from measured values AO09A (EPA 8270; EPA 609)","search_zh":"饮用水、地表水、地下水、废水、工艺用水和海水、浸出液 GC/MSD法测定硝基芳烃和苯胺类并由测量值计算其总和 AO09A (EPA 8270; EPA 609)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f18c06132ec70803b1963288","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"63","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady","methodology":"Oznaczanie nitrozwiązków aromatycznych i anilin metodą GC/MSD i obliczenie ich sum z wartości zmierzonych","methodology_en":"Determination of nitroaromatics and anilines by GC/MSD and calculation of their sums from measured values","methodology_zh":"GC/MSD法测定硝基芳烃和苯胺类并由测量值计算其总和","methodology_cs":"Stanovení nitroaromátů a anilinů metodou GC/MSD a výpočet sum nitroaromátů a anilinů z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie nitrozwiązków aromatycznych i anilin metodą GC/MSD i obliczenie ich sum z wartości zmierzonych","reference":"AO09B (EPA 8270; EPA 609)","norm_bases":["AO09B","EPA 8270","EPA 609"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): Anilin, azobenzen, benzidin, Bis-(2-chlorethoxy)methan, Bis-(1,3-dichlorpropyl)ether, Bis-(2,3-dichlorpropyl)ether, 1,3-dichlorpropyl-2,3-dichlorpropylether, 4-bromfenylether, 2-chloranilin, 3-chloranilin, 4-chloranilin, 1-chlor-2,4-dinitrobenzen, 4-chlorfenylether, 4-chlor-3-methylfenol, 1-chlornaftalen, 2-chlornaftalen, 4-chlor-2-nitroanilin, 2-chlor-4-nitrotoluen, 4-chlor-2-nitrotoluen, DEET, diazinon, 3,3‘-dichlorbenzidin, 2,4-dichloranilin, 3,4-dichloranilin, 3,4-dichlor-nitrobenzen, 2,4-dinitrotoluen, 2,6-dinitrotoluen, N-ethylanilin, fenitrotihion, fenylether, hexachlorbutadien, hexachlorcyklopentadien, hexachlorethan, 2-methyl-4,6-dinitrofenol (DNOK), 2-nitroanilin, nitrobenzen, 2-nitrofenol, 4-nitrofenol, N-nitroso-di-N-propylamin, 2-nitrotoluen, 3-nitrotoluen, 4-nitrotoluen, tributylfosfát, trifluralin.","note_en":"Determined analytes (analyte names as in the Czech original): Anilin, azobenzen, benzidin, Bis-(2-chlorethoxy)methan, Bis-(1,3-dichlorpropyl)ether, Bis-(2,3-dichlorpropyl)ether, 1,3-dichlorpropyl-2,3-dichlorpropylether, 4-bromfenylether, 2-chloranilin, 3-chloranilin, 4-chloranilin, 1-chlor-2,4-dinitrobenzen, 4-chlorfenylether, 4-chlor-3-methylfenol, 1-chlornaftalen, 2-chlornaftalen, 4-chlor-2-nitroanilin, 2-chlor-4-nitrotoluen, 4-chlor-2-nitrotoluen, DEET, diazinon, 3,3‘-dichlorbenzidin, 2,4-dichloranilin, 3,4-dichloranilin, 3,4-dichlor-nitrobenzen, 2,4-dinitrotoluen, 2,6-dinitrotoluen, N-ethylanilin, fenitrotihion, fenylether, hexachlorbutadien, hexachlorcyklopentadien, hexachlorethan, 2-methyl-4,6-dinitrofenol (DNOK), 2-nitroanilin, nitrobenzen, 2-nitrofenol, 4-nitrofenol, N-nitroso-di-N-propylamin, 2-nitrotoluen, 3-nitrotoluen, 4-nitrotoluen, tributylfosfát, trifluralin.","note_zh":"测定的分析物（分析物名称同捷克语原文）：Anilin, azobenzen, benzidin, Bis-(2-chlorethoxy)methan, Bis-(1,3-dichlorpropyl)ether, Bis-(2,3-dichlorpropyl)ether, 1,3-dichlorpropyl-2,3-dichlorpropylether, 4-bromfenylether, 2-chloranilin, 3-chloranilin, 4-chloranilin, 1-chlor-2,4-dinitrobenzen, 4-chlorfenylether, 4-chlor-3-methylfenol, 1-chlornaftalen, 2-chlornaftalen, 4-chlor-2-nitroanilin, 2-chlor-4-nitrotoluen, 4-chlor-2-nitrotoluen, DEET, diazinon, 3,3‘-dichlorbenzidin, 2,4-dichloranilin, 3,4-dichloranilin, 3,4-dichlor-nitrobenzen, 2,4-dinitrotoluen, 2,6-dinitrotoluen, N-ethylanilin, fenitrotihion, fenylether, hexachlorbutadien, hexachlorcyklopentadien, hexachlorethan, 2-methyl-4,6-dinitrofenol (DNOK), 2-nitroanilin, nitrobenzen, 2-nitrofenol, 4-nitrofenol, N-nitroso-di-N-propylamin, 2-nitrotoluen, 3-nitrotoluen, 4-nitrotoluen, tributylfosfát, trifluralin.","note_cs":"Anilin, azobenzen, benzidin, Bis-(2-chlorethoxy)methan, Bis-(1,3-dichlorpropyl)ether, Bis-(2,3-dichlorpropyl)ether, 1,3-dichlorpropyl-2,3-dichlorpropylether, 4-bromfenylether, 2-chloranilin, 3-chloranilin, 4-chloranilin, 1-chlor-2,4-dinitrobenzen, 4-chlorfenylether, 4-chlor-3-methylfenol, 1-chlornaftalen, 2-chlornaftalen, 4-chlor-2-nitroanilin, 2-chlor-4-nitrotoluen, 4-chlor-2-nitrotoluen, DEET, diazinon, 3,3‘-dichlorbenzidin, 2,4-dichloranilin, 3,4-dichloranilin, 3,4-dichlor-nitrobenzen, 2,4-dinitrotoluen, 2,6-dinitrotoluen, N-ethylanilin, fenitrotihion, fenylether, hexachlorbutadien, hexachlorcyklopentadien, hexachlorethan, 2-methyl-4,6-dinitrofenol (DNOK), 2-nitroanilin, nitrobenzen, 2-nitrofenol, 4-nitrofenol, N-nitroso-di-N-propylamin, 2-nitrotoluen, 3-nitrotoluen, 4-nitrotoluen, tributylfosfát, trifluralin.","search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe Oznaczanie nitrozwiązków aromatycznych i anilin metodą GC/MSD i obliczenie ich sum z wartości zmierzonych Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady Stanovení nitroaromátů a anilinů metodou GC/MSD a výpočet sum nitroaromátů a anilinů z naměřených hodnot AO09B (EPA 8270; EPA 609) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale Oznaczanie nitrozwiazkow aromatycznych i anilin metoda GC/MSD i obliczenie ich sum z wartosci zmierzonych Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady Stanoveni nitroaromatu a anilinu metodou GC/MSD a vypocet sum nitroaromatu a anilinu z namerenych hodnot AO09B (EPA 8270; EPA 609)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste Determination of nitroaromatics and anilines by GC/MSD and calculation of their sums from measured values AO09B (EPA 8270; EPA 609)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物 GC/MSD法测定硝基芳烃和苯胺类并由测量值计算其总和 AO09B (EPA 8270; EPA 609)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f69f438aecc717c2ac497734","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"64","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie kwasów aminopolikarboksylowych (EDTA, NTA, PDTA) metodą GC/NPD","methodology_en":"Determination of aminopolycarboxylic acids (EDTA, NTA, PDTA) by GC/NPD","methodology_zh":"GC/NPD法测定氨基多羧酸（EDTA、NTA、PDTA）","methodology_cs":"Stanovení aminopolykarboxylových kyselin (EDTA, NTA, PDTA) metodou GC/NPD","parameters":[{"name":"NTA (kwas nitrylotrioctowy)","range":""},{"name":"EDTA (kwas etylenodiaminotetraoctowy)","range":""},{"name":"1,3-PDTA (kwas 1,3-propylenodiaminotetraoctowy)","range":""}],"parameters_en":[{"name":"NTA (nitrilotriacetic acid)","range":""},{"name":"EDTA (ethylenediaminetetraacetic acid)","range":""},{"name":"1,3-PDTA (1,3-propylenediaminetetraacetic acid)","range":""}],"parameters_zh":[{"name":"NTA（次氮基三乙酸）","range":""},{"name":"EDTA（乙二胺四乙酸）","range":""},{"name":"1,3-PDTA（1,3-丙二胺四乙酸）","range":""}],"parameters_cs":[{"name":"NTA","range":""},{"name":"EDTA","range":""},{"name":"1,3-PDTA","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kwasów aminopolikarboksylowych (EDTA, NTA, PDTA) metodą GC/NPD\nZakres:\nNTA (kwas nitrylotrioctowy)\nEDTA (kwas etylenodiaminotetraoctowy)\n1,3-PDTA (kwas 1,3-propylenodiaminotetraoctowy)","reference":"AO11A (ČSN EN ISO 16588)","norm_bases":["AO11A","ČSN EN ISO 16588"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie kwasów aminopolikarboksylowych (EDTA, NTA, PDTA) metodą GC/NPD NTA (kwas nitrylotrioctowy)  EDTA (kwas etylenodiaminotetraoctowy)  1,3-PDTA (kwas 1,3-propylenodiaminotetraoctowy)  Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení aminopolykarboxylových kyselin (EDTA, NTA, PDTA) metodou GC/NPD NTA  EDTA  1,3-PDTA  AO11A (ČSN EN ISO 16588) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie kwasow aminopolikarboksylowych (EDTA, NTA, PDTA) metoda GC/NPD NTA (kwas nitrylotrioctowy)  EDTA (kwas etylenodiaminotetraoctowy)  1,3-PDTA (kwas 1,3-propylenodiaminotetraoctowy)  Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni aminopolykarboxylovych kyselin (EDTA, NTA, PDTA) metodou GC/NPD NTA  EDTA  1,3-PDTA  AO11A (CSN EN ISO 16588)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of aminopolycarboxylic acids (EDTA, NTA, PDTA) by GC/NPD NTA (nitrilotriacetic acid)  EDTA (ethylenediaminetetraacetic acid)  1,3-PDTA (1,3-propylenediaminetetraacetic acid)  AO11A (ČSN EN ISO 16588)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 GC/NPD法测定氨基多羧酸（EDTA、NTA、PDTA） NTA（次氮基三乙酸）  EDTA（乙二胺四乙酸）  1,3-PDTA（1,3-丙二胺四乙酸）  AO11A (ČSN EN ISO 16588)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c079a6119e90a008c0e6cbb6","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"65","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie węglowodorów C10 do C40 metodą GC/FID","methodology_en":"Determination of C10 to C40 hydrocarbons by GC/FID","methodology_zh":"GC/FID法测定C10至C40烃","methodology_cs":"Stanovení uhlovodíků C10 až C40 metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C10 do C40 metodą GC/FID","reference":"AO14A (ČSN EN ISO 9377-2)","norm_bases":["AO14A","ČSN EN ISO 9377-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): aliph. >C10-C12, aliph. >C12-C16, aliph. >C16-C21, aliph. >C21-C36, aliph. >C36>C40, arom. >C10-C12, arom. >C12-C16, arom. >C16-C21, arom. >C21-C36.","note_en":"Determined analytes (analyte names as in the Czech original): aliph. >C10-C12, aliph. >C12-C16, aliph. >C16-C21, aliph. >C21-C36, aliph. >C36>C40, arom. >C10-C12, arom. >C12-C16, arom. >C16-C21, arom. >C21-C36.","note_zh":"测定的分析物（分析物名称同捷克语原文）：aliph. >C10-C12, aliph. >C12-C16, aliph. >C16-C21, aliph. >C21-C36, aliph. >C36>C40, arom. >C10-C12, arom. >C12-C16, arom. >C16-C21, arom. >C21-C36.","note_cs":"aliph. >C10-C12, aliph. >C12-C16, aliph. >C16-C21, aliph. >C21-C36, aliph. >C36>C40, arom. >C10-C12, arom. >C12-C16, arom. >C16-C21, arom. >C21-C36.","search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie węglowodorów C10 do C40 metodą GC/FID Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení uhlovodíků C10 až C40 metodou GC/FID AO14A (ČSN EN ISO 9377-2) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie weglowodorow C10 do C40 metoda GC/FID Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni uhlovodiku C10 az C40 metodou GC/FID AO14A (CSN EN ISO 9377-2)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of C10 to C40 hydrocarbons by GC/FID AO14A (ČSN EN ISO 9377-2)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 GC/FID法测定C10至C40烃 AO14A (ČSN EN ISO 9377-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e8dd66e98440b23db9fe936b","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"66","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, dializat z próbnika pasywnego","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, dialysate from a passive sampler","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器透析液","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, dialyzát z pasivního vzorkovače","methodology":"Oznaczanie zawartości węglowodorów C10 do C40 metodą GC/FID","methodology_en":"Determination of C10 to C40 hydrocarbon content by GC/FID","methodology_zh":"GC/FID法测定C10至C40烃含量","methodology_cs":"Stanovení obsahu uhlovodíků C10 až C40 metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości węglowodorów C10 do C40 metodą GC/FID","reference":"AO14B (ČSN EN 14039; ČSN EN ISO 16703)","norm_bases":["AO14B","ČSN EN 14039","ČSN EN ISO 16703"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): aliph. >C10-C12, aliph. >C12-C16, aliph. >C16-C21, aliph. >C21-C36, aliph. >C36>C40, arom. >C10-C12, arom. >C12-C16, arom. >C16-C21, arom. >C21-C36.","note_en":"Determined analytes (analyte names as in the Czech original): aliph. >C10-C12, aliph. >C12-C16, aliph. >C16-C21, aliph. >C21-C36, aliph. >C36>C40, arom. >C10-C12, arom. >C12-C16, arom. >C16-C21, arom. >C21-C36.","note_zh":"测定的分析物（分析物名称同捷克语原文）：aliph. >C10-C12, aliph. >C12-C16, aliph. >C16-C21, aliph. >C21-C36, aliph. >C36>C40, arom. >C10-C12, arom. >C12-C16, arom. >C16-C21, arom. >C21-C36.","note_cs":"aliph. >C10-C12, aliph. >C12-C16, aliph. >C16-C21, aliph. >C21-C36, aliph. >C36>C40, arom. >C10-C12, arom. >C12-C16, arom. >C16-C21, arom. >C21-C36.","search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, dializat z próbnika pasywnego Oznaczanie zawartości węglowodorów C10 do C40 metodą GC/FID Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, dialyzát z pasivního vzorkovače Stanovení obsahu uhlovodíků C10 až C40 metodou GC/FID AO14B (ČSN EN 14039; ČSN EN ISO 16703) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale, dializat z probnika pasywnego Oznaczanie zawartosci weglowodorow C10 do C40 metoda GC/FID Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady, dialyzat z pasivniho vzorkovace Stanoveni obsahu uhlovodiku C10 az C40 metodou GC/FID AO14B (CSN EN 14039; CSN EN ISO 16703)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, dialysate from a passive sampler Determination of C10 to C40 hydrocarbon content by GC/FID AO14B (ČSN EN 14039; ČSN EN ISO 16703)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器透析液 GC/FID法测定C10至C40烃含量 AO14B (ČSN EN 14039; ČSN EN ISO 16703)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c1bddaabde5d7b22c2156b5b","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"67","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne i ścieki","test_object_en":"Drinking, surface, ground and waste water","test_object_zh":"饮用水、地表水、地下水和废水","test_object_cs":"Vody pitné, povrchové, podzemní a odpadní","methodology":"Oznaczanie pestycydów i leków metodą LC/MS/MS i obliczenie ich sum z wartości zmierzonych","methodology_en":"Determination of pesticides and pharmaceuticals by LC/MS/MS and calculation of their sums from measured values","methodology_zh":"LC/MS/MS法测定农药和药物并由测量值计算其总和","methodology_cs":"Stanovení pesticidů a léčiv metodou LC/MS/MS a výpočet sum pesticidů a léčiv z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pestycydów i leków metodą LC/MS/MS i obliczenie ich sum z wartości zmierzonych","reference":"AO17A (ČSN ISO 25101; ČSN EN 15637; EPA 1694; EPA 535; EPA 536; EPA 539)","norm_bases":["AO17A","ČSN ISO 25101","ČSN EN 15637","EPA 1694","EPA 535","EPA 536","EPA 539"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): 4-acetamidoantipyrin, acetaminophen, acesulfam, acetamiprid, amoxicillin, azitromycin, acetochlor, acetochlor-ESA, acebutolol, allopurinol, amitriptilline, ampicillin, kwas antranilowy, azoxystrobin acetochlor-OA, kwas acetylosalicylowy, aclonifen, alachlor, alachlor-ESA, alachlor-OA, aldicarb, ametryn, atenolol, aminopyralid, amitraz, atorvastatin, atraton, atrazin, atrazin-desethyl-desisopropyl, atrazin-2-hydroxy, avobenzon (butyl-methoxydibenzoylmethan), azoxystrobin o-demethyl, bentazon, benzophenon, buturon, benzotriazol, benzotriazol-methyl, betaxolol, bezafibrat, bisfenol A, bromacil, bromoxynil bifenox, boscalid, butachlor, butylfosfát, carbamazepin, carbendazim, carbofuran, carboxin, cefazoline, cefotaxime, celecoxib, cetirizin, citalopram, claritromycin, clethodim, cotinine, cyprodinil, cyproconazol, ciprofloxacin, clomazon, clopyralid, cyanazin, DCSA, decylbenzensulfonát (LAS-C10), DEET, desethylatrazin, desisopropylatrazin, desmedipham, desmethylcitalopram, desmetryn, diatrizoate, diazinon, 2,6-dichlorbenzamid, dichlormid, dimethachlor CGA 369873, dimethenamid, dimethenamid ESA, dimethenamid OA, desogestrel, dibuthylfosfát (DBP), dicamba, diclofenac, dichlorprop (2,4-DP), dichlorvos, dimethachlor, dimethachlor ESA, dimethachlor OA, dimethoate, diuron, diaverdin, difenoconazol, diflufenican, dichlobenil, diltiazem, dimethomorph, dimoxystrobin, diuron-desmethyl, dodecafluoro-3H-4,8-dioxanonanoate (ADONA), dodecylbenzensulfonát (LAS-C12), dosulepin, doxycyklin, enalapril, enrofloxacin, epoxiconazol, ethinylestradiol (EE2), ethofumesat, erytromycin, alfa-estradiol, beta-estradiol (E2), estriol (E3), estrone (E1), estron-3-sulfát, famoxadon, fenarimol, fenbendazol, fenitrothion, fenofibrat, fexofenadine, fenuron, flusilazol, fenthion, fenhexamid, fipronil, fluazifop, fluazifop-p-butyl, flufenacet, flufenacet ESA, flufenacet OA, flukonazol, fluopikolid, fluoxetin, fluroxypyr, FOSA, N-Methyl-FOSA, fenpropidin, fenpropimorph, foramsulfuron, gabapentin, gabapentin laktam, gemfibrozil, haloxyfop-methyl, alfa-hexabromcyklododekan, beta-hexabromcyklododekan, gama-hexabromcyklododekan, hexazinon, hydrochlorthiazid, chloramphenicol, chlorbromuron, chlorfenvinfos, chloridazon, chloridazon-desphenyl, chloridazon-methyl-desphenyl, chlorpyrifos, chlorpyrifos-methyl, chlorsulfuron, chlortetracyklin, chlortoluron, chlortoluron-N-desmethyl, ibuprofen, imazalil, imazethapyr, imidacloprid, impramine, iodosulfuron-methyl, ipkonazol, iprovalikarb, isoproturon-desmethyl (1-(4-isopropylphenyl)urea), indomethacin, iprodione, isoproturon-monodesmethyl, iohexol, iomeprol, iopamidol, iopromid, ivermectin, irbesartan, irgarol (cybutryn), isoproturon, ketoprofen, klindamycin, kwas klofibrowy, klothianidin, klotrimazol, kresoxim-methyl, kofein, kwas chlorooctowy (MCAA), kwas bromooctowy (MBAA), kwas dichlorooctowy (DCAA), kwas trichlorooctowy (TCAA), kwas bromochlorooctowy (BCAA), kwas dibromooctowy (DBAA), kwas bromodichlorooctowy (BDCAA), kwas chlorodibromooctowy (CDBAA), kwas tribromooctowy (TBAA), lamotrigin, lansoprazol, levonorgestrel, lenacil, lidokain, lincomycin, linuron, malathion, maprotiline, MCPA, MCPB, MCPP (mecoprop), medroxyprogesteron, MeFOSA, melamin, mepanipyrim, metformin, methamidophos, methidathion, methoxyfenozid, metribuzin-desamino, mefenpyr-diethyl, metaflumizon, methiocarb, metalaxyl, metamitron, metazachlor, metazachlor ESA, metazachlor OA, metconazol, methabenzthiazuron, metobromuron, metolachlor, metolachlor-ESA, metolachlor-OA, metoprolol, metoxuron, metribuzin, MEtribuzin-diketo, metribuzin-desamino-diketo, mikonazol, monensin, monolinuron, monuron, maproxen, napropamid, nicotin, nicosulfuron, norfloxacin, nortriptiline, ofloxacin, oktokrylen, omeprazol, omethoat, oxacilin, oxadiazon, oxybenzon (benzofenon-3), oxypurinol, oxytetracyklin, pendimethalin, penicilin G, penicilin V, penkonazol, pentoxifyllin, 2-perfluorohexyl ethanol (6:2 FTOH), perfluoro-2-methyl-3-oxahexanoate, 2-perfluorooktyl ethanol (8:2 FTOH), pethoxamid, pethoxamid ESA, PFHxS, PFNA, phosalone, phosphamidon, phorate, phthalylsulfathiazol, pirimicarb, pirimiphos methyl, propamocarb, propaquizafop, pyridate, PFBA, PFPeA, PFHxA, PFHxDA, PFHpA, PFNA, PFDA, PFUdA, PFDoA, PFTrDA, PFTeDA, PFBS, PFHxS, PFHpS, PFDS, PFOA, PFODA, PFDS, PFOS, 1H,1H,2H,2H- PFOS (6:2-FTS), phenmedipham, phenazon, picolinafen, picloram, piperacilin, primidon, progesteron, prochloraz, prometryn, propachlor, propachlor-ESA, propachlor OA, propargit, propazin, propiconazol, propyphenazon, propyzamid, prosulfocarb, prothioconazole, pyraklostrobin, rimsulfuron, roxitromycin, quinmerac, quinoxyfen (chinoxyfen), kwas salicylowy, sebuthylazin, sertralin, simazin, simazin 2-hydroxy, sitagliptin, sotalol, spiroxamin, sulfachlorpyridazine, sulfaclozin, sulfadiazin, sulfadimethoxin, sulfadoxin, sulfamerazin, sulfamethazin, sulfamethoxazol, sulfamonomethoxin, sulfapyridin, sulfathiazol, sulfosulfuron, tebuconazol, telmisartan, terbuthylazin, terbuthylazin-desethyl, terbuthylazin-2-hydroxy, terbutryn, terbuthylazin-des-2-hydroxy, tiamulin, thiacloprid, thiophanate-methyl, triadimefon, triadimenol, triallate, triasulfuron, tribenuron-methyl, triclosan, trifloxystrobin, triticonazol, testosteron, tetracyklin, tetrakonazol, thiacloprid, thiamethoxam, thifensulfuron-methyl, torasemid, tramadol, trazodone, 1,2,4-triazol, tributhylfosfát (TBP), tridecylbenzensulfonát (LAS-C13), triethylfosfát (TEP), trifenylfosfát TPP), triflusulfuron-methyl, triisobutylfosfát (TiBP), trimethoprim, trinexapac, tris-2-butoxyethyl-fosfát (TBEP), tris(2-chlorethyl)fosfát (TCEP), tris(2-chlorisopropyl)fosfát (TCPP), tylosin, undecylbenzensulfonát (LAS-C11), 2,4-D, 2,4-DB, 2,4,5-T, 1-(4-isopropylphenyl)urea, kwas 3-fenoksybenzoesowy, 3-methyl-4-nitrofenol, N-chloroacetyl-2,6-diethylaniline, valsartan, kwas walsartanowy (w oryginale „valtarsanová”), venlafaxin, venlafaxin-O-desmethyl, verapamil, warfarin, kwas perfluoroundekanosulfonowy (PFUnDS), kwas perfluorododekanosulfonowy (PFDoDS), kwas perfluorotridekanosulfonowy (PFTrDS), amisulprid, propranolol, bromuconazol, climbazol, cyazofamid, amisulbrom, itraconazol, ketoconazol, 6-PPD, 6-PPD-quinon, abamectin, abamectin B1a (avermectin B1a), abamectin B1b (avermectin B1b), octisalat, sucralose, candesartan, mesotrion, guanylurea, mefentrifluconazol, PFPeS, PFNS, HFPO-DA (GenX), F-Diox acid (C6O4), trifluoroacetic acid (TFA).","note_en":"Determined analytes (analyte names as in the Czech original): 4-acetamidoantipyrin, acetaminophen, acesulfam, acetamiprid, amoxicillin, azitromycin, acetochlor, acetochlor-ESA, acebutolol, allopurinol, amitriptilline, ampicillin, anthranilic acid, azoxystrobin acetochlor-OA, acetylsalicylic acid, aclonifen, alachlor, alachlor-ESA, alachlor-OA, aldicarb, ametryn, atenolol, aminopyralid, amitraz, atorvastatin, atraton, atrazin, atrazin-desethyl-desisopropyl, atrazin-2-hydroxy, avobenzon (butyl-methoxydibenzoylmethan), azoxystrobin o-demethyl, bentazon, benzophenon, buturon, benzotriazol, benzotriazol-methyl, betaxolol, bezafibrat, bisfenol A, bromacil, bromoxynil bifenox, boscalid, butachlor, butylfosfát, carbamazepin, carbendazim, carbofuran, carboxin, cefazoline, cefotaxime, celecoxib, cetirizin, citalopram, claritromycin, clethodim, cotinine, cyprodinil, cyproconazol, ciprofloxacin, clomazon, clopyralid, cyanazin, DCSA, decylbenzensulfonát (LAS-C10), DEET, desethylatrazin, desisopropylatrazin, desmedipham, desmethylcitalopram, desmetryn, diatrizoate, diazinon, 2,6-dichlorbenzamid, dichlormid, dimethachlor CGA 369873, dimethenamid, dimethenamid ESA, dimethenamid OA, desogestrel, dibuthylfosfát (DBP), dicamba, diclofenac, dichlorprop (2,4-DP), dichlorvos, dimethachlor, dimethachlor ESA, dimethachlor OA, dimethoate, diuron, diaverdin, difenoconazol, diflufenican, dichlobenil, diltiazem, dimethomorph, dimoxystrobin, diuron-desmethyl, dodecafluoro-3H-4,8-dioxanonanoate (ADONA), dodecylbenzensulfonát (LAS-C12), dosulepin, doxycyklin, enalapril, enrofloxacin, epoxiconazol, ethinylestradiol (EE2), ethofumesat, erytromycin, alfa-estradiol, beta-estradiol (E2), estriol (E3), estrone (E1), estron-3-sulfát, famoxadon, fenarimol, fenbendazol, fenitrothion, fenofibrat, fexofenadine, fenuron, flusilazol, fenthion, fenhexamid, fipronil, fluazifop, fluazifop-p-butyl, flufenacet, flufenacet ESA, flufenacet OA, flukonazol, fluopikolid, fluoxetin, fluroxypyr, FOSA, N-Methyl-FOSA, fenpropidin, fenpropimorph, foramsulfuron, gabapentin, gabapentin laktam, gemfibrozil, haloxyfop-methyl, alfa-hexabromcyklododekan, beta-hexabromcyklododekan, gama-hexabromcyklododekan, hexazinon, hydrochlorthiazid, chloramphenicol, chlorbromuron, chlorfenvinfos, chloridazon, chloridazon-desphenyl, chloridazon-methyl-desphenyl, chlorpyrifos, chlorpyrifos-methyl, chlorsulfuron, chlortetracyklin, chlortoluron, chlortoluron-N-desmethyl, ibuprofen, imazalil, imazethapyr, imidacloprid, impramine, iodosulfuron-methyl, ipkonazol, iprovalikarb, isoproturon-desmethyl (1-(4-isopropylphenyl)urea), indomethacin, iprodione, isoproturon-monodesmethyl, iohexol, iomeprol, iopamidol, iopromid, ivermectin, irbesartan, irgarol (cybutryn), isoproturon, ketoprofen, klindamycin, clofibric acid, klothianidin, klotrimazol, kresoxim-methyl, kofein, chloroacetic acid (MCAA), bromoacetic acid (MBAA), dichloroacetic acid (DCAA), trichloroacetic acid (TCAA), bromochloroacetic acid (BCAA), dibromoacetic acid (DBAA), bromodichloroacetic acid (BDCAA), chlorodibromoacetic acid (CDBAA), tribromoacetic acid (TBAA), lamotrigin, lansoprazol, levonorgestrel, lenacil, lidokain, lincomycin, linuron, malathion, maprotiline, MCPA, MCPB, MCPP (mecoprop), medroxyprogesteron, MeFOSA, melamin, mepanipyrim, metformin, methamidophos, methidathion, methoxyfenozid, metribuzin-desamino, mefenpyr-diethyl, metaflumizon, methiocarb, metalaxyl, metamitron, metazachlor, metazachlor ESA, metazachlor OA, metconazol, methabenzthiazuron, metobromuron, metolachlor, metolachlor-ESA, metolachlor-OA, metoprolol, metoxuron, metribuzin, MEtribuzin-diketo, metribuzin-desamino-diketo, mikonazol, monensin, monolinuron, monuron, maproxen, napropamid, nicotin, nicosulfuron, norfloxacin, nortriptiline, ofloxacin, oktokrylen, omeprazol, omethoat, oxacilin, oxadiazon, oxybenzon (benzofenon-3), oxypurinol, oxytetracyklin, pendimethalin, penicilin G, penicilin V, penkonazol, pentoxifyllin, 2-perfluorohexyl ethanol (6:2 FTOH), perfluoro-2-methyl-3-oxahexanoate, 2-perfluorooktyl ethanol (8:2 FTOH), pethoxamid, pethoxamid ESA, PFHxS, PFNA, phosalone, phosphamidon, phorate, phthalylsulfathiazol, pirimicarb, pirimiphos methyl, propamocarb, propaquizafop, pyridate, PFBA, PFPeA, PFHxA, PFHxDA, PFHpA, PFNA, PFDA, PFUdA, PFDoA, PFTrDA, PFTeDA, PFBS, PFHxS, PFHpS, PFDS, PFOA, PFODA, PFDS, PFOS, 1H,1H,2H,2H- PFOS (6:2-FTS), phenmedipham, phenazon, picolinafen, picloram, piperacilin, primidon, progesteron, prochloraz, prometryn, propachlor, propachlor-ESA, propachlor OA, propargit, propazin, propiconazol, propyphenazon, propyzamid, prosulfocarb, prothioconazole, pyraklostrobin, rimsulfuron, roxitromycin, quinmerac, quinoxyfen (chinoxyfen), salicylic acid, sebuthylazin, sertralin, simazin, simazin 2-hydroxy, sitagliptin, sotalol, spiroxamin, sulfachlorpyridazine, sulfaclozin, sulfadiazin, sulfadimethoxin, sulfadoxin, sulfamerazin, sulfamethazin, sulfamethoxazol, sulfamonomethoxin, sulfapyridin, sulfathiazol, sulfosulfuron, tebuconazol, telmisartan, terbuthylazin, terbuthylazin-desethyl, terbuthylazin-2-hydroxy, terbutryn, terbuthylazin-des-2-hydroxy, tiamulin, thiacloprid, thiophanate-methyl, triadimefon, triadimenol, triallate, triasulfuron, tribenuron-methyl, triclosan, trifloxystrobin, triticonazol, testosteron, tetracyklin, tetrakonazol, thiacloprid, thiamethoxam, thifensulfuron-methyl, torasemid, tramadol, trazodone, 1,2,4-triazol, tributhylfosfát (TBP), tridecylbenzensulfonát (LAS-C13), triethylfosfát (TEP), trifenylfosfát TPP), triflusulfuron-methyl, triisobutylfosfát (TiBP), trimethoprim, trinexapac, tris-2-butoxyethyl-fosfát (TBEP), tris(2-chlorethyl)fosfát (TCEP), tris(2-chlorisopropyl)fosfát (TCPP), tylosin, undecylbenzensulfonát (LAS-C11), 2,4-D, 2,4-DB, 2,4,5-T, 1-(4-isopropylphenyl)urea, 3-phenoxybenzoic acid, 3-methyl-4-nitrofenol, N-chloroacetyl-2,6-diethylaniline, valsartan, valsartan acid (“valtarsanová” in the original), venlafaxin, venlafaxin-O-desmethyl, verapamil, warfarin, perfluoroundecanesulfonic acid (PFUnDS), perfluorododecanesulfonic acid (PFDoDS), perfluorotridecanesulfonic acid (PFTrDS), amisulprid, propranolol, bromuconazol, climbazol, cyazofamid, amisulbrom, itraconazol, ketoconazol, 6-PPD, 6-PPD-quinon, abamectin, abamectin B1a (avermectin B1a), abamectin B1b (avermectin B1b), octisalat, sucralose, candesartan, mesotrion, guanylurea, mefentrifluconazol, PFPeS, PFNS, HFPO-DA (GenX), F-Diox acid (C6O4), trifluoroacetic acid (TFA).","note_zh":"测定的分析物（分析物名称同捷克语原文）：4-acetamidoantipyrin, acetaminophen, acesulfam, acetamiprid, amoxicillin, azitromycin, acetochlor, acetochlor-ESA, acebutolol, allopurinol, amitriptilline, ampicillin, anthranilic acid, azoxystrobin acetochlor-OA, acetylsalicylic acid, aclonifen, alachlor, alachlor-ESA, alachlor-OA, aldicarb, ametryn, atenolol, aminopyralid, amitraz, atorvastatin, atraton, atrazin, atrazin-desethyl-desisopropyl, atrazin-2-hydroxy, avobenzon (butyl-methoxydibenzoylmethan), azoxystrobin o-demethyl, bentazon, benzophenon, buturon, benzotriazol, benzotriazol-methyl, betaxolol, bezafibrat, bisfenol A, bromacil, bromoxynil bifenox, boscalid, butachlor, butylfosfát, carbamazepin, carbendazim, carbofuran, carboxin, cefazoline, cefotaxime, celecoxib, cetirizin, citalopram, claritromycin, clethodim, cotinine, cyprodinil, cyproconazol, ciprofloxacin, clomazon, clopyralid, cyanazin, DCSA, decylbenzensulfonát (LAS-C10), DEET, desethylatrazin, desisopropylatrazin, desmedipham, desmethylcitalopram, desmetryn, diatrizoate, diazinon, 2,6-dichlorbenzamid, dichlormid, dimethachlor CGA 369873, dimethenamid, dimethenamid ESA, dimethenamid OA, desogestrel, dibuthylfosfát (DBP), dicamba, diclofenac, dichlorprop (2,4-DP), dichlorvos, dimethachlor, dimethachlor ESA, dimethachlor OA, dimethoate, diuron, diaverdin, difenoconazol, diflufenican, dichlobenil, diltiazem, dimethomorph, dimoxystrobin, diuron-desmethyl, dodecafluoro-3H-4,8-dioxanonanoate (ADONA), dodecylbenzensulfonát (LAS-C12), dosulepin, doxycyklin, enalapril, enrofloxacin, epoxiconazol, ethinylestradiol (EE2), ethofumesat, erytromycin, alfa-estradiol, beta-estradiol (E2), estriol (E3), estrone (E1), estron-3-sulfát, famoxadon, fenarimol, fenbendazol, fenitrothion, fenofibrat, fexofenadine, fenuron, flusilazol, fenthion, fenhexamid, fipronil, fluazifop, fluazifop-p-butyl, flufenacet, flufenacet ESA, flufenacet OA, flukonazol, fluopikolid, fluoxetin, fluroxypyr, FOSA, N-Methyl-FOSA, fenpropidin, fenpropimorph, foramsulfuron, gabapentin, gabapentin laktam, gemfibrozil, haloxyfop-methyl, alfa-hexabromcyklododekan, beta-hexabromcyklododekan, gama-hexabromcyklododekan, hexazinon, hydrochlorthiazid, chloramphenicol, chlorbromuron, chlorfenvinfos, chloridazon, chloridazon-desphenyl, chloridazon-methyl-desphenyl, chlorpyrifos, chlorpyrifos-methyl, chlorsulfuron, chlortetracyklin, chlortoluron, chlortoluron-N-desmethyl, ibuprofen, imazalil, imazethapyr, imidacloprid, impramine, iodosulfuron-methyl, ipkonazol, iprovalikarb, isoproturon-desmethyl (1-(4-isopropylphenyl)urea), indomethacin, iprodione, isoproturon-monodesmethyl, iohexol, iomeprol, iopamidol, iopromid, ivermectin, irbesartan, irgarol (cybutryn), isoproturon, ketoprofen, klindamycin, clofibric acid, klothianidin, klotrimazol, kresoxim-methyl, kofein, chloroacetic acid (MCAA), bromoacetic acid (MBAA), dichloroacetic acid (DCAA), trichloroacetic acid (TCAA), bromochloroacetic acid (BCAA), dibromoacetic acid (DBAA), bromodichloroacetic acid (BDCAA), chlorodibromoacetic acid (CDBAA), tribromoacetic acid (TBAA), lamotrigin, lansoprazol, levonorgestrel, lenacil, lidokain, lincomycin, linuron, malathion, maprotiline, MCPA, MCPB, MCPP (mecoprop), medroxyprogesteron, MeFOSA, melamin, mepanipyrim, metformin, methamidophos, methidathion, methoxyfenozid, metribuzin-desamino, mefenpyr-diethyl, metaflumizon, methiocarb, metalaxyl, metamitron, metazachlor, metazachlor ESA, metazachlor OA, metconazol, methabenzthiazuron, metobromuron, metolachlor, metolachlor-ESA, metolachlor-OA, metoprolol, metoxuron, metribuzin, MEtribuzin-diketo, metribuzin-desamino-diketo, mikonazol, monensin, monolinuron, monuron, maproxen, napropamid, nicotin, nicosulfuron, norfloxacin, nortriptiline, ofloxacin, oktokrylen, omeprazol, omethoat, oxacilin, oxadiazon, oxybenzon (benzofenon-3), oxypurinol, oxytetracyklin, pendimethalin, penicilin G, penicilin V, penkonazol, pentoxifyllin, 2-perfluorohexyl ethanol (6:2 FTOH), perfluoro-2-methyl-3-oxahexanoate, 2-perfluorooktyl ethanol (8:2 FTOH), pethoxamid, pethoxamid ESA, PFHxS, PFNA, phosalone, phosphamidon, phorate, phthalylsulfathiazol, pirimicarb, pirimiphos methyl, propamocarb, propaquizafop, pyridate, PFBA, PFPeA, PFHxA, PFHxDA, PFHpA, PFNA, PFDA, PFUdA, PFDoA, PFTrDA, PFTeDA, PFBS, PFHxS, PFHpS, PFDS, PFOA, PFODA, PFDS, PFOS, 1H,1H,2H,2H- PFOS (6:2-FTS), phenmedipham, phenazon, picolinafen, picloram, piperacilin, primidon, progesteron, prochloraz, prometryn, propachlor, propachlor-ESA, propachlor OA, propargit, propazin, propiconazol, propyphenazon, propyzamid, prosulfocarb, prothioconazole, pyraklostrobin, rimsulfuron, roxitromycin, quinmerac, quinoxyfen (chinoxyfen), salicylic acid, sebuthylazin, sertralin, simazin, simazin 2-hydroxy, sitagliptin, sotalol, spiroxamin, sulfachlorpyridazine, sulfaclozin, sulfadiazin, sulfadimethoxin, sulfadoxin, sulfamerazin, sulfamethazin, sulfamethoxazol, sulfamonomethoxin, sulfapyridin, sulfathiazol, sulfosulfuron, tebuconazol, telmisartan, terbuthylazin, terbuthylazin-desethyl, terbuthylazin-2-hydroxy, terbutryn, terbuthylazin-des-2-hydroxy, tiamulin, thiacloprid, thiophanate-methyl, triadimefon, triadimenol, triallate, triasulfuron, tribenuron-methyl, triclosan, trifloxystrobin, triticonazol, testosteron, tetracyklin, tetrakonazol, thiacloprid, thiamethoxam, thifensulfuron-methyl, torasemid, tramadol, trazodone, 1,2,4-triazol, tributhylfosfát (TBP), tridecylbenzensulfonát (LAS-C13), triethylfosfát (TEP), trifenylfosfát TPP), triflusulfuron-methyl, triisobutylfosfát (TiBP), trimethoprim, trinexapac, tris-2-butoxyethyl-fosfát (TBEP), tris(2-chlorethyl)fosfát (TCEP), tris(2-chlorisopropyl)fosfát (TCPP), tylosin, undecylbenzensulfonát (LAS-C11), 2,4-D, 2,4-DB, 2,4,5-T, 1-(4-isopropylphenyl)urea, 3-phenoxybenzoic acid, 3-methyl-4-nitrofenol, N-chloroacetyl-2,6-diethylaniline, valsartan, valsartan acid (“valtarsanová” in the original), venlafaxin, venlafaxin-O-desmethyl, verapamil, warfarin, perfluoroundecanesulfonic acid (PFUnDS), perfluorododecanesulfonic acid (PFDoDS), perfluorotridecanesulfonic acid (PFTrDS), amisulprid, propranolol, bromuconazol, climbazol, cyazofamid, amisulbrom, itraconazol, ketoconazol, 6-PPD, 6-PPD-quinon, abamectin, abamectin B1a (avermectin B1a), abamectin B1b (avermectin B1b), octisalat, sucralose, candesartan, mesotrion, guanylurea, mefentrifluconazol, PFPeS, PFNS, HFPO-DA (GenX), F-Diox acid (C6O4), trifluoroacetic acid (TFA).","note_cs":"4-acetamidoantipyrin, acetaminophen, acesulfam, acetamiprid, amoxicillin, azitromycin, acetochlor, acetochlor-ESA, acebutolol, allopurinol, amitriptilline, ampicillin, anthranilová kyselina, azoxystrobin acetochlor-OA, acetylsalicylová kyselina, aclonifen, alachlor, alachlor-ESA, alachlor-OA, aldicarb, ametryn, atenolol, aminopyralid, amitraz, atorvastatin, atraton, atrazin, atrazin-desethyl-desisopropyl, atrazin-2-hydroxy, avobenzon (butyl-methoxydibenzoylmethan), azoxystrobin o-demethyl, bentazon, benzophenon, buturon, benzotriazol, benzotriazol-methyl, betaxolol, bezafibrat, bisfenol A, bromacil, bromoxynil bifenox, boscalid, butachlor, butylfosfát, carbamazepin, carbendazim, carbofuran, carboxin, cefazoline, cefotaxime, celecoxib, cetirizin, citalopram, claritromycin, clethodim, cotinine, cyprodinil, cyproconazol, ciprofloxacin, clomazon, clopyralid, cyanazin, DCSA, decylbenzensulfonát (LAS-C10), DEET, desethylatrazin, desisopropylatrazin, desmedipham, desmethylcitalopram, desmetryn, diatrizoate, diazinon, 2,6-dichlorbenzamid, dichlormid, dimethachlor CGA 369873, dimethenamid, dimethenamid ESA, dimethenamid OA, desogestrel, dibuthylfosfát (DBP), dicamba, diclofenac, dichlorprop (2,4-DP), dichlorvos, dimethachlor, dimethachlor ESA, dimethachlor OA, dimethoate, diuron, diaverdin, difenoconazol, diflufenican, dichlobenil, diltiazem, dimethomorph, dimoxystrobin, diuron-desmethyl, dodecafluoro-3H-4,8-dioxanonanoate (ADONA), dodecylbenzensulfonát (LAS-C12), dosulepin, doxycyklin, enalapril, enrofloxacin, epoxiconazol, ethinylestradiol (EE2), ethofumesat, erytromycin, alfa-estradiol, beta-estradiol (E2), estriol (E3), estrone (E1), estron-3-sulfát, famoxadon, fenarimol, fenbendazol, fenitrothion, fenofibrat, fexofenadine, fenuron, flusilazol, fenthion, fenhexamid, fipronil, fluazifop, fluazifop-p-butyl, flufenacet, flufenacet ESA, flufenacet OA, flukonazol, fluopikolid, fluoxetin, fluroxypyr, FOSA, N-Methyl-FOSA, fenpropidin, fenpropimorph, foramsulfuron, gabapentin, gabapentin laktam, gemfibrozil, haloxyfop-methyl, alfa-hexabromcyklododekan, beta-hexabromcyklododekan, gama-hexabromcyklododekan, hexazinon, hydrochlorthiazid, chloramphenicol, chlorbromuron, chlorfenvinfos, chloridazon, chloridazon-desphenyl, chloridazon-methyl-desphenyl, chlorpyrifos, chlorpyrifos-methyl, chlorsulfuron, chlortetracyklin, chlortoluron, chlortoluron-N-desmethyl, ibuprofen, imazalil, imazethapyr, imidacloprid, impramine, iodosulfuron-methyl, ipkonazol, iprovalikarb, isoproturon-desmethyl (1-(4-isopropylphenyl)urea), indomethacin, iprodione, isoproturon-monodesmethyl, iohexol, iomeprol, iopamidol, iopromid, ivermectin, irbesartan, irgarol (cybutryn), isoproturon, ketoprofen, klindamycin, klofibrová kyselina, klothianidin, klotrimazol, kresoxim-methyl, kofein, kyselina chloroctová (MCAA), kyselina bromoctová (MBAA), kyselina dichloroctová (DCAA), kyselina trichloroctová (TCAA), kyselina bromchloroctová (BCAA), kyselina dibromoctová (DBAA), kyselina bromdichloroctová (BDCAA), kyselina chlordibromoctová (CDBAA), kyselina tribromoctová (TBAA), lamotrigin, lansoprazol, levonorgestrel, lenacil, lidokain, lincomycin, linuron, malathion, maprotiline, MCPA, MCPB, MCPP (mecoprop), medroxyprogesteron, MeFOSA, melamin, mepanipyrim, metformin, methamidophos, methidathion, methoxyfenozid, metribuzin-desamino, mefenpyr-diethyl, metaflumizon, methiocarb, metalaxyl, metamitron, metazachlor, metazachlor ESA, metazachlor OA, metconazol, methabenzthiazuron, metobromuron, metolachlor, metolachlor-ESA, metolachlor-OA, metoprolol, metoxuron, metribuzin, MEtribuzin-diketo, metribuzin-desamino-diketo, mikonazol, monensin, monolinuron, monuron, maproxen, napropamid, nicotin, nicosulfuron, norfloxacin, nortriptiline, ofloxacin, oktokrylen, omeprazol, omethoat, oxacilin, oxadiazon, oxybenzon (benzofenon-3), oxypurinol, oxytetracyklin, pendimethalin, penicilin G, penicilin V, penkonazol, pentoxifyllin, 2-perfluorohexyl ethanol (6:2 FTOH), perfluoro-2-methyl-3-oxahexanoate, 2-perfluorooktyl ethanol (8:2 FTOH), pethoxamid, pethoxamid ESA, PFHxS, PFNA, phosalone, phosphamidon, phorate, phthalylsulfathiazol, pirimicarb, pirimiphos methyl, propamocarb, propaquizafop, pyridate, PFBA, PFPeA, PFHxA, PFHxDA, PFHpA, PFNA, PFDA, PFUdA, PFDoA, PFTrDA, PFTeDA, PFBS, PFHxS, PFHpS, PFDS, PFOA, PFODA, PFDS, PFOS, 1H,1H,2H,2H- PFOS (6:2-FTS), phenmedipham, phenazon, picolinafen, picloram, piperacilin, primidon, progesteron, prochloraz, prometryn, propachlor, propachlor-ESA, propachlor OA, propargit, propazin, propiconazol, propyphenazon, propyzamid, prosulfocarb, prothioconazole, pyraklostrobin, rimsulfuron, roxitromycin, quinmerac, quinoxyfen (chinoxyfen), salicylová kyselina, sebuthylazin, sertralin, simazin, simazin 2-hydroxy, sitagliptin, sotalol, spiroxamin, sulfachlorpyridazine, sulfaclozin, sulfadiazin, sulfadimethoxin, sulfadoxin, sulfamerazin, sulfamethazin, sulfamethoxazol, sulfamonomethoxin, sulfapyridin, sulfathiazol, sulfosulfuron, tebuconazol, telmisartan, terbuthylazin, terbuthylazin-desethyl, terbuthylazin-2-hydroxy, terbutryn, terbuthylazin-des-2-hydroxy, tiamulin, thiacloprid, thiophanate-methyl, triadimefon, triadimenol, triallate, triasulfuron, tribenuron-methyl, triclosan, trifloxystrobin, triticonazol, testosteron, tetracyklin, tetrakonazol, thiacloprid, thiamethoxam, thifensulfuron-methyl, torasemid, tramadol, trazodone, 1,2,4-triazol, tributhylfosfát (TBP), tridecylbenzensulfonát (LAS-C13), triethylfosfát (TEP), trifenylfosfát TPP), triflusulfuron-methyl, triisobutylfosfát (TiBP), trimethoprim, trinexapac, tris-2-butoxyethyl-fosfát (TBEP), tris(2-chlorethyl)fosfát (TCEP), tris(2-chlorisopropyl)fosfát (TCPP), tylosin, undecylbenzensulfonát (LAS-C11), 2,4-D, 2,4-DB, 2,4,5-T, 1-(4-isopropylphenyl)urea, 3-fenoxybenzoová kyselina, 3-methyl-4-nitrofenol, N-chloroacetyl-2,6-diethylaniline, valsartan, valtarsanová kyselina, venlafaxin, venlafaxin-O-desmethyl, verapamil, warfarin, perfluorundekansulfonová kyselina (PFUnDS), perfluordodekansulfonová kyselina (PFDoDS), perfluortridekansulfonová kyselina (PFTrDS), amisulprid, propranolol, bromuconazol, climbazol, cyazofamid, amisulbrom, itraconazol, ketoconazol, 6-PPD, 6-PPD-quinon, abamectin, abamectin B1a (avermectin B1a), abamectin B1b (avermectin B1b), octisalat, sucralose, candesartan, mesotrion, guanylurea, mefentrifluconazol, PFPeS, PFNS, HFPO-DA (GenX), F-Diox acid (C6O4), trifluoroacetic acid (TFA).","search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne i ścieki Oznaczanie pestycydów i leków metodą LC/MS/MS i obliczenie ich sum z wartości zmierzonych Vody pitné, povrchové, podzemní a odpadní Stanovení pesticidů a léčiv metodou LC/MS/MS a výpočet sum pesticidů a léčiv z naměřených hodnot AO17A (ČSN ISO 25101; ČSN EN 15637; EPA 1694; EPA 535; EPA 536; EPA 539) Wody przeznaczone do spozycia, powierzchniowe, podziemne i scieki Oznaczanie pestycydow i lekow metoda LC/MS/MS i obliczenie ich sum z wartosci zmierzonych Vody pitne, povrchove, podzemni a odpadni Stanoveni pesticidu a leciv metodou LC/MS/MS a vypocet sum pesticidu a leciv z namerenych hodnot AO17A (CSN ISO 25101; CSN EN 15637; EPA 1694; EPA 535; EPA 536; EPA 539)","search_en":"Drinking, surface, ground and waste water Determination of pesticides and pharmaceuticals by LC/MS/MS and calculation of their sums from measured values AO17A (ČSN ISO 25101; ČSN EN 15637; EPA 1694; EPA 535; EPA 536; EPA 539)","search_zh":"饮用水、地表水、地下水和废水 LC/MS/MS法测定农药和药物并由测量值计算其总和 AO17A (ČSN ISO 25101; ČSN EN 15637; EPA 1694; EPA 535; EPA 536; EPA 539)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"493fa64f3f566dd1117e1cef","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"68","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, eluat z próbnika pasywnego","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, eluate from a passive sampler","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器洗脱液","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, eluát z pasivního vzorkovače","methodology":"Oznaczanie pestycydów i leków metodą LC/MS/MS i obliczenie ich sum z wartości zmierzonych","methodology_en":"Determination of pesticides and pharmaceuticals by LC/MS/MS and calculation of their sums from measured values","methodology_zh":"LC/MS/MS法测定农药和药物并由测量值计算其总和","methodology_cs":"Stanovení pesticidů a léčiv metodou LC/MS/MS a výpočet sum pesticidů a léčiv z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pestycydów i leków metodą LC/MS/MS i obliczenie ich sum z wartości zmierzonych","reference":"AO17B (ČSN EN 15637; EPA 1694)","norm_bases":["AO17B","ČSN EN 15637","EPA 1694"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): Acetaminophen, acetamiprid, acebutolol, acetochlor, acetochlor-ESA, acetochlor-OA, aclonifen, alachlor, alachlor-ESA, alachlor-OA, aldicarb, ametryn, N-chloroacetyl-2,6-diethylaniline, kwas antranilowy, atenolol, atorvastatin, atraton, atrazin, atrazin-desethyl-desisopropyl, atrazin-2-hydroxy, azitromycin, azoxystrobin, bentazon, benzotriazol, benzotriazol-methyl, , betaxolol, bifenox, boscalid, bromacil, bromoxynil, buturon, butylfosfát, carbamazepin, carbendazim, carbofuran, carboxin, celecoxib, clomazon, cotinine, cyanazin, cyproconazol, DEET, desethylatrazin, desisopropylatrazin, desmedipham, desmetryn, diatrizoate, diazinon, dibuthylfosfát (DBP), diaverdin, difenoconazol, diflufenican, dichlobenil, diltiazem, dimethomorph, dimoxystrobin, diuron-desmethyl, dicamba, diclofenac, 2,6-dichlorbenzamid, dichlorprop (2,4-DP), dichlorvos, dimethachlor, dimethachlor-ESA, dimethoate, diuron, epoxiconazol, ethofumesat, enalapril, erytromycin, fenarimol, fenpropidin, fenpropimorph fenitrothion, fenofibrat, kwas 3-fenoksybenzoesowy, fenthion, fenuron, fenhexamid, fipronil, flusilazol, fluazifop, fluazifop-p-butyl, flufenacet, fluroxypyr, FOSA, MeFOSA, gabapentin, gemfibrozil, alfa-hexabromcyklododekan, beta-hexabromcyklododekan, gama-hexabromcyklododekan, hexazinon, chloramphenicol, chlorbromuron, chlorfenvinphos, chloridazon, chloridazon-methyl-desphenyl, chlorpyrifos, chlorpyrifos-methyl, chlorsulfuron, chlortoluron, chlortoluron-N-desmethyl, ibuprofen, imazethapyr, indomethacin, iprodione, isoproturon-monodesmethyl, iohexol, iomeprol, iopamidol, iopromid, irgarol (cybutryn), isoproturon, ketoprofen, klaritromycin, klothianidin, kofein, kwas klofibrowy, kresoxim-methyl, lansoprazol, levonorgestrel, lenacil, linuron, malathion, MCPA, MCPB, MCPP (mecoprop), medroxyprogesteron, mefenpyrdiethyl, mepanipyrim, metalaxyl, metamitron, metazachlor, metazachlor-ESA, metconazol, methabenzthiazuron, methamidophos, methidathion, methoxyfenozid, metribuzin-desamino, metobromuron, metolachlor, metolachlor-ESA, metolachlor-OA, metoprolol, metoxuron, metribuzin, monolinuron, monuron, napropamid, naproxen, nicotin, nicosulfuron, 3-methyl-4-nitrofenol, omeprazol, oxacilin, pethoxamid, PFHxS, PFNA, phenazon, phosalone, phosphamidon, phorate, pirimicarb, propamocarb, propaquizafop, pyridate, pendimethalin, pentoxifyllin, PFOA, PFOS, phenmedipham, picolinafen, primidon, prochloraz, prometryn, propachlor, propachlor ESA, propargit, propazin, propiconazol, propyphenazon, propyzamid, prosulfocarb, rimsulfuron, quinmerac, quinoxyfen (chinoxyfen), roxitromycin, sebuthylazin, simazin, simazin 2-hydroxy, sotalol, spiroxamin, sulfadiazin, sulfadimethoxin, sulfamerazin, sulfamethazin, sulfamethoxazol, sulfapyridin, sulfosulfuron, tebuconazol, terbuthylazin, terbuthylazin-des-2-hydroxy, terbuthylazin-desethyl, terbuthylazin-2-hydroxy, terbutryn, thiacloprid, tiamulin, thiamethoxam, thiophanate-methyl, thifensulfuron-methyl, tramadol, tributhylfosfát (TBP), trifenylfosfát (TPP), triflusulfuron-methyl, trimethoprim, tris-2-butoxyethyl-fosfát (TBEP), triisobutylfosfát (TiBP), tris(2-chlorethyl)fosfát (TCEP), tris(2-chlorisopropyl)fosfát (TCPP), tylosin, 2,4-D, 2,4,5-T, 2,4,5-TPbezafibratcyprodinil, triadimefon, triadimenol, triallate, triasulfuron, tribenuron-methyl, trifloxystrobin, trinexapac, triticonazol, 1-(4-isopropylphenyl)urea, verapamil, warfarin.","note_en":"Determined analytes (analyte names as in the Czech original): Acetaminophen, acetamiprid, acebutolol, acetochlor, acetochlor-ESA, acetochlor-OA, aclonifen, alachlor, alachlor-ESA, alachlor-OA, aldicarb, ametryn, N-chloroacetyl-2,6-diethylaniline, anthranilic acid, atenolol, atorvastatin, atraton, atrazin, atrazin-desethyl-desisopropyl, atrazin-2-hydroxy, azitromycin, azoxystrobin, bentazon, benzotriazol, benzotriazol-methyl, , betaxolol, bifenox, boscalid, bromacil, bromoxynil, buturon, butylfosfát, carbamazepin, carbendazim, carbofuran, carboxin, celecoxib, clomazon, cotinine, cyanazin, cyproconazol, DEET, desethylatrazin, desisopropylatrazin, desmedipham, desmetryn, diatrizoate, diazinon, dibuthylfosfát (DBP), diaverdin, difenoconazol, diflufenican, dichlobenil, diltiazem, dimethomorph, dimoxystrobin, diuron-desmethyl, dicamba, diclofenac, 2,6-dichlorbenzamid, dichlorprop (2,4-DP), dichlorvos, dimethachlor, dimethachlor-ESA, dimethoate, diuron, epoxiconazol, ethofumesat, enalapril, erytromycin, fenarimol, fenpropidin, fenpropimorph fenitrothion, fenofibrat, 3-phenoxybenzoic acid, fenthion, fenuron, fenhexamid, fipronil, flusilazol, fluazifop, fluazifop-p-butyl, flufenacet, fluroxypyr, FOSA, MeFOSA, gabapentin, gemfibrozil, alfa-hexabromcyklododekan, beta-hexabromcyklododekan, gama-hexabromcyklododekan, hexazinon, chloramphenicol, chlorbromuron, chlorfenvinphos, chloridazon, chloridazon-methyl-desphenyl, chlorpyrifos, chlorpyrifos-methyl, chlorsulfuron, chlortoluron, chlortoluron-N-desmethyl, ibuprofen, imazethapyr, indomethacin, iprodione, isoproturon-monodesmethyl, iohexol, iomeprol, iopamidol, iopromid, irgarol (cybutryn), isoproturon, ketoprofen, klaritromycin, klothianidin, kofein, clofibric acid, kresoxim-methyl, lansoprazol, levonorgestrel, lenacil, linuron, malathion, MCPA, MCPB, MCPP (mecoprop), medroxyprogesteron, mefenpyrdiethyl, mepanipyrim, metalaxyl, metamitron, metazachlor, metazachlor-ESA, metconazol, methabenzthiazuron, methamidophos, methidathion, methoxyfenozid, metribuzin-desamino, metobromuron, metolachlor, metolachlor-ESA, metolachlor-OA, metoprolol, metoxuron, metribuzin, monolinuron, monuron, napropamid, naproxen, nicotin, nicosulfuron, 3-methyl-4-nitrofenol, omeprazol, oxacilin, pethoxamid, PFHxS, PFNA, phenazon, phosalone, phosphamidon, phorate, pirimicarb, propamocarb, propaquizafop, pyridate, pendimethalin, pentoxifyllin, PFOA, PFOS, phenmedipham, picolinafen, primidon, prochloraz, prometryn, propachlor, propachlor ESA, propargit, propazin, propiconazol, propyphenazon, propyzamid, prosulfocarb, rimsulfuron, quinmerac, quinoxyfen (chinoxyfen), roxitromycin, sebuthylazin, simazin, simazin 2-hydroxy, sotalol, spiroxamin, sulfadiazin, sulfadimethoxin, sulfamerazin, sulfamethazin, sulfamethoxazol, sulfapyridin, sulfosulfuron, tebuconazol, terbuthylazin, terbuthylazin-des-2-hydroxy, terbuthylazin-desethyl, terbuthylazin-2-hydroxy, terbutryn, thiacloprid, tiamulin, thiamethoxam, thiophanate-methyl, thifensulfuron-methyl, tramadol, tributhylfosfát (TBP), trifenylfosfát (TPP), triflusulfuron-methyl, trimethoprim, tris-2-butoxyethyl-fosfát (TBEP), triisobutylfosfát (TiBP), tris(2-chlorethyl)fosfát (TCEP), tris(2-chlorisopropyl)fosfát (TCPP), tylosin, 2,4-D, 2,4,5-T, 2,4,5-TPbezafibratcyprodinil, triadimefon, triadimenol, triallate, triasulfuron, tribenuron-methyl, trifloxystrobin, trinexapac, triticonazol, 1-(4-isopropylphenyl)urea, verapamil, warfarin.","note_zh":"测定的分析物（分析物名称同捷克语原文）：Acetaminophen, acetamiprid, acebutolol, acetochlor, acetochlor-ESA, acetochlor-OA, aclonifen, alachlor, alachlor-ESA, alachlor-OA, aldicarb, ametryn, N-chloroacetyl-2,6-diethylaniline, anthranilic acid, atenolol, atorvastatin, atraton, atrazin, atrazin-desethyl-desisopropyl, atrazin-2-hydroxy, azitromycin, azoxystrobin, bentazon, benzotriazol, benzotriazol-methyl, , betaxolol, bifenox, boscalid, bromacil, bromoxynil, buturon, butylfosfát, carbamazepin, carbendazim, carbofuran, carboxin, celecoxib, clomazon, cotinine, cyanazin, cyproconazol, DEET, desethylatrazin, desisopropylatrazin, desmedipham, desmetryn, diatrizoate, diazinon, dibuthylfosfát (DBP), diaverdin, difenoconazol, diflufenican, dichlobenil, diltiazem, dimethomorph, dimoxystrobin, diuron-desmethyl, dicamba, diclofenac, 2,6-dichlorbenzamid, dichlorprop (2,4-DP), dichlorvos, dimethachlor, dimethachlor-ESA, dimethoate, diuron, epoxiconazol, ethofumesat, enalapril, erytromycin, fenarimol, fenpropidin, fenpropimorph fenitrothion, fenofibrat, 3-phenoxybenzoic acid, fenthion, fenuron, fenhexamid, fipronil, flusilazol, fluazifop, fluazifop-p-butyl, flufenacet, fluroxypyr, FOSA, MeFOSA, gabapentin, gemfibrozil, alfa-hexabromcyklododekan, beta-hexabromcyklododekan, gama-hexabromcyklododekan, hexazinon, chloramphenicol, chlorbromuron, chlorfenvinphos, chloridazon, chloridazon-methyl-desphenyl, chlorpyrifos, chlorpyrifos-methyl, chlorsulfuron, chlortoluron, chlortoluron-N-desmethyl, ibuprofen, imazethapyr, indomethacin, iprodione, isoproturon-monodesmethyl, iohexol, iomeprol, iopamidol, iopromid, irgarol (cybutryn), isoproturon, ketoprofen, klaritromycin, klothianidin, kofein, clofibric acid, kresoxim-methyl, lansoprazol, levonorgestrel, lenacil, linuron, malathion, MCPA, MCPB, MCPP (mecoprop), medroxyprogesteron, mefenpyrdiethyl, mepanipyrim, metalaxyl, metamitron, metazachlor, metazachlor-ESA, metconazol, methabenzthiazuron, methamidophos, methidathion, methoxyfenozid, metribuzin-desamino, metobromuron, metolachlor, metolachlor-ESA, metolachlor-OA, metoprolol, metoxuron, metribuzin, monolinuron, monuron, napropamid, naproxen, nicotin, nicosulfuron, 3-methyl-4-nitrofenol, omeprazol, oxacilin, pethoxamid, PFHxS, PFNA, phenazon, phosalone, phosphamidon, phorate, pirimicarb, propamocarb, propaquizafop, pyridate, pendimethalin, pentoxifyllin, PFOA, PFOS, phenmedipham, picolinafen, primidon, prochloraz, prometryn, propachlor, propachlor ESA, propargit, propazin, propiconazol, propyphenazon, propyzamid, prosulfocarb, rimsulfuron, quinmerac, quinoxyfen (chinoxyfen), roxitromycin, sebuthylazin, simazin, simazin 2-hydroxy, sotalol, spiroxamin, sulfadiazin, sulfadimethoxin, sulfamerazin, sulfamethazin, sulfamethoxazol, sulfapyridin, sulfosulfuron, tebuconazol, terbuthylazin, terbuthylazin-des-2-hydroxy, terbuthylazin-desethyl, terbuthylazin-2-hydroxy, terbutryn, thiacloprid, tiamulin, thiamethoxam, thiophanate-methyl, thifensulfuron-methyl, tramadol, tributhylfosfát (TBP), trifenylfosfát (TPP), triflusulfuron-methyl, trimethoprim, tris-2-butoxyethyl-fosfát (TBEP), triisobutylfosfát (TiBP), tris(2-chlorethyl)fosfát (TCEP), tris(2-chlorisopropyl)fosfát (TCPP), tylosin, 2,4-D, 2,4,5-T, 2,4,5-TPbezafibratcyprodinil, triadimefon, triadimenol, triallate, triasulfuron, tribenuron-methyl, trifloxystrobin, trinexapac, triticonazol, 1-(4-isopropylphenyl)urea, verapamil, warfarin.","note_cs":"Acetaminophen, acetamiprid, acebutolol, acetochlor, acetochlor-ESA, acetochlor-OA, aclonifen, alachlor, alachlor-ESA, alachlor-OA, aldicarb, ametryn, N-chloroacetyl-2,6-diethylaniline, anthranilová kyselina, atenolol, atorvastatin, atraton, atrazin, atrazin-desethyl-desisopropyl, atrazin-2-hydroxy, azitromycin, azoxystrobin, bentazon, benzotriazol, benzotriazol-methyl, , betaxolol, bifenox, boscalid, bromacil, bromoxynil, buturon, butylfosfát, carbamazepin, carbendazim, carbofuran, carboxin, celecoxib, clomazon, cotinine, cyanazin, cyproconazol, DEET, desethylatrazin, desisopropylatrazin, desmedipham, desmetryn, diatrizoate, diazinon, dibuthylfosfát (DBP), diaverdin, difenoconazol, diflufenican, dichlobenil, diltiazem, dimethomorph, dimoxystrobin, diuron-desmethyl, dicamba, diclofenac, 2,6-dichlorbenzamid, dichlorprop (2,4-DP), dichlorvos, dimethachlor, dimethachlor-ESA, dimethoate, diuron, epoxiconazol, ethofumesat, enalapril, erytromycin, fenarimol, fenpropidin, fenpropimorph fenitrothion, fenofibrat, 3-fenoxybenzoová kyselina, fenthion, fenuron, fenhexamid, fipronil, flusilazol, fluazifop, fluazifop-p-butyl, flufenacet, fluroxypyr, FOSA, MeFOSA, gabapentin, gemfibrozil, alfa-hexabromcyklododekan, beta-hexabromcyklododekan, gama-hexabromcyklododekan, hexazinon, chloramphenicol, chlorbromuron, chlorfenvinphos, chloridazon, chloridazon-methyl-desphenyl, chlorpyrifos, chlorpyrifos-methyl, chlorsulfuron, chlortoluron, chlortoluron-N-desmethyl, ibuprofen, imazethapyr, indomethacin, iprodione, isoproturon-monodesmethyl, iohexol, iomeprol, iopamidol, iopromid, irgarol (cybutryn), isoproturon, ketoprofen, klaritromycin, klothianidin, kofein, klofibrová kyselina, kresoxim-methyl, lansoprazol, levonorgestrel, lenacil, linuron, malathion, MCPA, MCPB, MCPP (mecoprop), medroxyprogesteron, mefenpyrdiethyl, mepanipyrim, metalaxyl, metamitron, metazachlor, metazachlor-ESA, metconazol, methabenzthiazuron, methamidophos, methidathion, methoxyfenozid, metribuzin-desamino, metobromuron, metolachlor, metolachlor-ESA, metolachlor-OA, metoprolol, metoxuron, metribuzin, monolinuron, monuron, napropamid, naproxen, nicotin, nicosulfuron, 3-methyl-4-nitrofenol, omeprazol, oxacilin, pethoxamid, PFHxS, PFNA, phenazon, phosalone, phosphamidon, phorate, pirimicarb, propamocarb, propaquizafop, pyridate, pendimethalin, pentoxifyllin, PFOA, PFOS, phenmedipham, picolinafen, primidon, prochloraz, prometryn, propachlor, propachlor ESA, propargit, propazin, propiconazol, propyphenazon, propyzamid, prosulfocarb, rimsulfuron, quinmerac, quinoxyfen (chinoxyfen), roxitromycin, sebuthylazin, simazin, simazin 2-hydroxy, sotalol, spiroxamin, sulfadiazin, sulfadimethoxin, sulfamerazin, sulfamethazin, sulfamethoxazol, sulfapyridin, sulfosulfuron, tebuconazol, terbuthylazin, terbuthylazin-des-2-hydroxy, terbuthylazin-desethyl, terbuthylazin-2-hydroxy, terbutryn, thiacloprid, tiamulin, thiamethoxam, thiophanate-methyl, thifensulfuron-methyl, tramadol, tributhylfosfát (TBP), trifenylfosfát (TPP), triflusulfuron-methyl, trimethoprim, tris-2-butoxyethyl-fosfát (TBEP), triisobutylfosfát (TiBP), tris(2-chlorethyl)fosfát (TCEP), tris(2-chlorisopropyl)fosfát (TCPP), tylosin, 2,4-D, 2,4,5-T, 2,4,5-TPbezafibratcyprodinil, triadimefon, triadimenol, triallate, triasulfuron, tribenuron-methyl, trifloxystrobin, trinexapac, triticonazol, 1-(4-isopropylphenyl)urea, verapamil, warfarin.","search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, eluat z próbnika pasywnego Oznaczanie pestycydów i leków metodą LC/MS/MS i obliczenie ich sum z wartości zmierzonych Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, eluát z pasivního vzorkovače Stanovení pesticidů a léčiv metodou LC/MS/MS a výpočet sum pesticidů a léčiv z naměřených hodnot AO17B (ČSN EN 15637; EPA 1694) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale, eluat z probnika pasywnego Oznaczanie pestycydow i lekow metoda LC/MS/MS i obliczenie ich sum z wartosci zmierzonych Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady, eluat z pasivniho vzorkovace Stanoveni pesticidu a leciv metodou LC/MS/MS a vypocet sum pesticidu a leciv z namerenych hodnot AO17B (CSN EN 15637; EPA 1694)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, eluate from a passive sampler Determination of pesticides and pharmaceuticals by LC/MS/MS and calculation of their sums from measured values AO17B (ČSN EN 15637; EPA 1694)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器洗脱液 LC/MS/MS法测定农药和药物并由测量值计算其总和 AO17B (ČSN EN 15637; EPA 1694)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bc85353f52acb07bebf7af15","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"69","test_object":"Materiał zwierzęcy i roślinny","test_object_en":"Animal and plant material","test_object_zh":"动物和植物材料","test_object_cs":"Živočišný a rostlinný materiál","methodology":"Oznaczanie pestycydów i leków metodą LC/MS/MS i obliczenie ich sum z wartości zmierzonych","methodology_en":"Determination of pesticides and pharmaceuticals by LC/MS/MS and calculation of their sums from measured values","methodology_zh":"LC/MS/MS法测定农药和药物并由测量值计算其总和","methodology_cs":"Stanovení pesticidů a léčiv metodou LC/MS/MS a výpočet sum pesticidů a léčiv z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pestycydów i leków metodą LC/MS/MS i obliczenie ich sum z wartości zmierzonych","reference":"AO17C ČSN EN 15637; EPA 1694)","norm_bases":["AO17C","ČSN EN 15637","EPA 1694"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): Acetochlor, alachlor, aldicarb, ametryn, atrazin, atrazin-2-hydroxy, bentazon, boscalid, butylfosfát, carbamazepin, carbendazim, carbofuran, clomazon, cyanazin, desethylatrazin, desisopropylatrazin, desmedipham, desmetryn, diatrizoate, dibuthylfosfát, dichlorprop (2,4-DP), dichlorvos, dimetachlor, dimethoate, diuron, epoxiconazol, ethofumesat, fenpropidin, fenpropimorph, hexazinon, chlorbromuron, chlorfenvinphos, chloridazon, chlorpyrifos, chlorpyrifos-methyl, chlorsulfuron, chlortoluron, chlortoluron-N-desmethyl, ibuprofen, iohexol, iomeprol, iopamidol, iopromid, irgarol (cybutryn), isoproturon, ketoprofen, kofein, lenacil, linuron, malathion, MCPA, MCPP, metalaxyl, metamitron, metazachlor, metconazol, methabenzthiazuron, metobromuron, metolachlor, metoprolol, metoxuron, metribuzin, monolinuron, monuron, naproxen, pendimethalin, pentoxifyllin, PFOA, PFOS, phenmedipham, picolinafen, primidon, prochloraz, prometryn, propachlor, propazin, propiconazol, propyphenazon, propyzamid, quinoxyfen (chinoxyfen), roxitromycin, sebuthylazin, simazin, spiroxamin, sulfadimethoxin, sulfamerazin, sulfamethazin, sulfamethoxazol, tebuconazol, terbuthylazin, terbuthylazin-desethyl, terbuthylazin-2-hydroxy, terbutryn, tramadol, tributhylfosfát (TBP), triethylfosfát (TEP), trifenylfosfát (TPP), triisobutylfosfát (TiBP), trimethoprim, tris-2-butoxyethyl-fosfát (TBEP), tris(2-chlorethyl)fosfát (TCEP), tylosin, 2,4-D, 2,4,5-T, 2,4,5-TP.","note_en":"Determined analytes (analyte names as in the Czech original): Acetochlor, alachlor, aldicarb, ametryn, atrazin, atrazin-2-hydroxy, bentazon, boscalid, butylfosfát, carbamazepin, carbendazim, carbofuran, clomazon, cyanazin, desethylatrazin, desisopropylatrazin, desmedipham, desmetryn, diatrizoate, dibuthylfosfát, dichlorprop (2,4-DP), dichlorvos, dimetachlor, dimethoate, diuron, epoxiconazol, ethofumesat, fenpropidin, fenpropimorph, hexazinon, chlorbromuron, chlorfenvinphos, chloridazon, chlorpyrifos, chlorpyrifos-methyl, chlorsulfuron, chlortoluron, chlortoluron-N-desmethyl, ibuprofen, iohexol, iomeprol, iopamidol, iopromid, irgarol (cybutryn), isoproturon, ketoprofen, kofein, lenacil, linuron, malathion, MCPA, MCPP, metalaxyl, metamitron, metazachlor, metconazol, methabenzthiazuron, metobromuron, metolachlor, metoprolol, metoxuron, metribuzin, monolinuron, monuron, naproxen, pendimethalin, pentoxifyllin, PFOA, PFOS, phenmedipham, picolinafen, primidon, prochloraz, prometryn, propachlor, propazin, propiconazol, propyphenazon, propyzamid, quinoxyfen (chinoxyfen), roxitromycin, sebuthylazin, simazin, spiroxamin, sulfadimethoxin, sulfamerazin, sulfamethazin, sulfamethoxazol, tebuconazol, terbuthylazin, terbuthylazin-desethyl, terbuthylazin-2-hydroxy, terbutryn, tramadol, tributhylfosfát (TBP), triethylfosfát (TEP), trifenylfosfát (TPP), triisobutylfosfát (TiBP), trimethoprim, tris-2-butoxyethyl-fosfát (TBEP), tris(2-chlorethyl)fosfát (TCEP), tylosin, 2,4-D, 2,4,5-T, 2,4,5-TP.","note_zh":"测定的分析物（分析物名称同捷克语原文）：Acetochlor, alachlor, aldicarb, ametryn, atrazin, atrazin-2-hydroxy, bentazon, boscalid, butylfosfát, carbamazepin, carbendazim, carbofuran, clomazon, cyanazin, desethylatrazin, desisopropylatrazin, desmedipham, desmetryn, diatrizoate, dibuthylfosfát, dichlorprop (2,4-DP), dichlorvos, dimetachlor, dimethoate, diuron, epoxiconazol, ethofumesat, fenpropidin, fenpropimorph, hexazinon, chlorbromuron, chlorfenvinphos, chloridazon, chlorpyrifos, chlorpyrifos-methyl, chlorsulfuron, chlortoluron, chlortoluron-N-desmethyl, ibuprofen, iohexol, iomeprol, iopamidol, iopromid, irgarol (cybutryn), isoproturon, ketoprofen, kofein, lenacil, linuron, malathion, MCPA, MCPP, metalaxyl, metamitron, metazachlor, metconazol, methabenzthiazuron, metobromuron, metolachlor, metoprolol, metoxuron, metribuzin, monolinuron, monuron, naproxen, pendimethalin, pentoxifyllin, PFOA, PFOS, phenmedipham, picolinafen, primidon, prochloraz, prometryn, propachlor, propazin, propiconazol, propyphenazon, propyzamid, quinoxyfen (chinoxyfen), roxitromycin, sebuthylazin, simazin, spiroxamin, sulfadimethoxin, sulfamerazin, sulfamethazin, sulfamethoxazol, tebuconazol, terbuthylazin, terbuthylazin-desethyl, terbuthylazin-2-hydroxy, terbutryn, tramadol, tributhylfosfát (TBP), triethylfosfát (TEP), trifenylfosfát (TPP), triisobutylfosfát (TiBP), trimethoprim, tris-2-butoxyethyl-fosfát (TBEP), tris(2-chlorethyl)fosfát (TCEP), tylosin, 2,4-D, 2,4,5-T, 2,4,5-TP.","note_cs":"Acetochlor, alachlor, aldicarb, ametryn, atrazin, atrazin-2-hydroxy, bentazon, boscalid, butylfosfát, carbamazepin, carbendazim, carbofuran, clomazon, cyanazin, desethylatrazin, desisopropylatrazin, desmedipham, desmetryn, diatrizoate, dibuthylfosfát, dichlorprop (2,4-DP), dichlorvos, dimetachlor, dimethoate, diuron, epoxiconazol, ethofumesat, fenpropidin, fenpropimorph, hexazinon, chlorbromuron, chlorfenvinphos, chloridazon, chlorpyrifos, chlorpyrifos-methyl, chlorsulfuron, chlortoluron, chlortoluron-N-desmethyl, ibuprofen, iohexol, iomeprol, iopamidol, iopromid, irgarol (cybutryn), isoproturon, ketoprofen, kofein, lenacil, linuron, malathion, MCPA, MCPP, metalaxyl, metamitron, metazachlor, metconazol, methabenzthiazuron, metobromuron, metolachlor, metoprolol, metoxuron, metribuzin, monolinuron, monuron, naproxen, pendimethalin, pentoxifyllin, PFOA, PFOS, phenmedipham, picolinafen, primidon, prochloraz, prometryn, propachlor, propazin, propiconazol, propyphenazon, propyzamid, quinoxyfen (chinoxyfen), roxitromycin, sebuthylazin, simazin, spiroxamin, sulfadimethoxin, sulfamerazin, sulfamethazin, sulfamethoxazol, tebuconazol, terbuthylazin, terbuthylazin-desethyl, terbuthylazin-2-hydroxy, terbutryn, tramadol, tributhylfosfát (TBP), triethylfosfát (TEP), trifenylfosfát (TPP), triisobutylfosfát (TiBP), trimethoprim, tris-2-butoxyethyl-fosfát (TBEP), tris(2-chlorethyl)fosfát (TCEP), tylosin, 2,4-D, 2,4,5-T, 2,4,5-TP.","search_text":"Materiał zwierzęcy i roślinny Oznaczanie pestycydów i leków metodą LC/MS/MS i obliczenie ich sum z wartości zmierzonych Živočišný a rostlinný materiál Stanovení pesticidů a léčiv metodou LC/MS/MS a výpočet sum pesticidů a léčiv z naměřených hodnot AO17C ČSN EN 15637; EPA 1694) Material zwierzecy i roslinny Oznaczanie pestycydow i lekow metoda LC/MS/MS i obliczenie ich sum z wartosci zmierzonych Zivocisny a rostlinny material Stanoveni pesticidu a leciv metodou LC/MS/MS a vypocet sum pesticidu a leciv z namerenych hodnot AO17C CSN EN 15637; EPA 1694)","search_en":"Animal and plant material Determination of pesticides and pharmaceuticals by LC/MS/MS and calculation of their sums from measured values AO17C ČSN EN 15637; EPA 1694)","search_zh":"动物和植物材料 LC/MS/MS法测定农药和药物并由测量值计算其总和 AO17C ČSN EN 15637; EPA 1694)","categories":["environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c939827517c8edaafa5ac4d6","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"70","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie PCB, pestycydów chloroorganicznych (OCP), polibromowanych difenyloeterów (PBDE), ftalanu bis(2-dietyloheksylu) (DEHP), związków piżmowych, pyretroidów i chloroalkanów C10 do C13 oraz C14 do C17 metodą GC/MS/MS, GC/EI-MSD, GC/NCI-MSD i obliczenie sum pestycydów i innych grup substancji z wartości zmierzonych","methodology_en":"Determination of PCB, organochlorine pesticides (OCP), polybrominated diphenyl ethers (PBDE), bis(2-diethylhexyl) phthalate (DEHP), musk compounds, pyrethroids and C10 to C13 and C14 to C17 chlorinated alkanes by GC/MS/MS, GC/EI-MSD, GC/NCI-MSD and calculation of sums of pesticides and other groups of substances from measured values","methodology_zh":"GC/MS/MS、GC/EI-MSD、GC/NCI-MSD法测定PCB、有机氯农药（OCP）、多溴二苯醚（PBDE）、邻苯二甲酸双(2-二乙基己基)酯（DEHP）、麝香类、拟除虫菊酯及C10至C13和C14至C17氯化烷烃，并由测量值计算农药及其他类别物质总和","methodology_cs":"Stanovení polychlorovaných bifenylů (PCB), organochlorových pesticidů (OCP), polybromovaných difenyletherů (PBDE), bis(2-diethylhexyl)ftalátu (DEHP), mošusových látek, pyrethroidů a chlorovaných alkanů C10 až C13 a C14 až C17 metodou GC/MS/MS, GC/EI-MSD, GC/NCI-MSD a výpočet sum pesticidů a dalších skupin látek z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie PCB, pestycydów chloroorganicznych (OCP), polibromowanych difenyloeterów (PBDE), ftalanu bis(2-dietyloheksylu) (DEHP), związków piżmowych, pyretroidów i chloroalkanów C10 do C13 oraz C14 do C17 metodą GC/MS/MS, GC/EI-MSD, GC/NCI-MSD i obliczenie sum pestycydów i innych grup substancji z wartości zmierzonych","reference":"AO18A (ČSN EN ISO 6468; ČSN EN ISO 18856; ISO 12010)","norm_bases":["AO18A","ČSN EN ISO 6468","ČSN EN ISO 18856","ISO 12010"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): PCB-6, PCB-7, PCB28, PCB31, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, heptachlor, methoxychlor, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, o,p-DDE, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-183, PBDE-209, DEHF, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, alachlor, chlorpyriphos, chlorpyriphos-methyl, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, trifluralin, propyzamide, chlorothalonil, triallate, ethofumesate, fluazifop-p-butyl, bifenthrine, deltamethrin, azoxystrobin, cypermethrin, α-cypermethrin, zeta-cypermethrin, beta-cyfluthrin, lambda-cyhalothrin, tau-fluvalinat, tefluthrin, musk keton, musk xylene, galaxolide (HHCB), tonalide (AHTN), 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, 1,2,4,5-tetrachlorbenzen, hexachlorbutadien (HCBD), chlordan, toxaphen, pentachlornitrobenzen, chloroalkany C10-C13, chloroalkany C14-C17, hexabromobenzen (HBB), pentabromoethylbenzen (PBEB), decabromodiphenylethane (DBDPE), bis(2-Ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), 1,2-bis(2,4,6-tribromophenoxy) ethane (BTBPE), 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (TBB), hexabromocyklododecane (HBCDD), dicofol, dimethylftalát (DMP), diethylftalát (DEP), dipropylftalát (DPP), diisobutylftalát (DiBP), dibutylftalát (DBP), butylbenzylftalát (BBzP), dipentylftalát (DPeP), dihexylftalát (DHP), dicyklohexylftalát (DCHP), bis(2-ethylhexyl)ftalát (DEHP), dioktylftalát (DOP), diisononylftalát (DiNP), diisodecylftalát (DIDP), naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenzo[a,h]anthracene, benzo[g,h,i]perylene, indeno[c,d]pyrene, 3,6-dimethylphenanthrene, perylene, benzo[a]fluorene, 1-methylnaphthalene, 4,4-dibromdiphenyl ether, hexabrombifenyl, bromopropylate, butralin, esfenvalerate, fenarimol, fenpropathrin, isofenphos, mirex, nitrofen, oxyfluorfen, permethrin, resmethrin, demeton, 2,4-D-1-butylester, 2,4-D-1-isobutylester, mirex, procymidone, propetamphos, quinalphos, tetrasul, tecnazene, vinclozolin, chlordecone (kepone), 4,4-Methylenebis(2,6-Di-Tert-butylphenol), 2-ethylhexyl-4-methoxycinnamát (Parsol SCX), 2,6-diterc-butyl-4-methylfenol, dekamethylcyklopentasiloxan, dekamethyltetratasiloxan (L4), dodekamethylcyklohexasiloxan, dodekamethylpentasiloxan (L5), 1,1,1,3,5,5,5-heptamethyltrisiloxan, 1,1,1,3,5,5,5-heptamethyltrisiloxan modyfikowany tlenkiem alkilenu, hexamethylcyklotrisiloxan, 1,1,3,3,5,5-hexamethyltrisiloxan, oktamethylcyklotetrasiloxan, oktamethyltrisiloxan (L3), etoxazol.","note_en":"Determined analytes (analyte names as in the Czech original): PCB-6, PCB-7, PCB28, PCB31, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, heptachlor, methoxychlor, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, o,p-DDE, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-183, PBDE-209, DEHF, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, alachlor, chlorpyriphos, chlorpyriphos-methyl, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, trifluralin, propyzamide, chlorothalonil, triallate, ethofumesate, fluazifop-p-butyl, bifenthrine, deltamethrin, azoxystrobin, cypermethrin, α-cypermethrin, zeta-cypermethrin, beta-cyfluthrin, lambda-cyhalothrin, tau-fluvalinat, tefluthrin, musk keton, musk xylene, galaxolide (HHCB), tonalide (AHTN), 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, 1,2,4,5-tetrachlorbenzen, hexachlorbutadien (HCBD), chlordan, toxaphen, pentachlornitrobenzen, chlorinated alkanes C10-C13, chlorinated alkanes C14-C17, hexabromobenzen (HBB), pentabromoethylbenzen (PBEB), decabromodiphenylethane (DBDPE), bis(2-Ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), 1,2-bis(2,4,6-tribromophenoxy) ethane (BTBPE), 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (TBB), hexabromocyklododecane (HBCDD), dicofol, dimethylftalát (DMP), diethylftalát (DEP), dipropylftalát (DPP), diisobutylftalát (DiBP), dibutylftalát (DBP), butylbenzylftalát (BBzP), dipentylftalát (DPeP), dihexylftalát (DHP), dicyklohexylftalát (DCHP), bis(2-ethylhexyl)ftalát (DEHP), dioktylftalát (DOP), diisononylftalát (DiNP), diisodecylftalát (DIDP), naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenzo[a,h]anthracene, benzo[g,h,i]perylene, indeno[c,d]pyrene, 3,6-dimethylphenanthrene, perylene, benzo[a]fluorene, 1-methylnaphthalene, 4,4-dibromdiphenyl ether, hexabrombifenyl, bromopropylate, butralin, esfenvalerate, fenarimol, fenpropathrin, isofenphos, mirex, nitrofen, oxyfluorfen, permethrin, resmethrin, demeton, 2,4-D-1-butylester, 2,4-D-1-isobutylester, mirex, procymidone, propetamphos, quinalphos, tetrasul, tecnazene, vinclozolin, chlordecone (kepone), 4,4-Methylenebis(2,6-Di-Tert-butylphenol), 2-ethylhexyl-4-methoxycinnamát (Parsol SCX), 2,6-diterc-butyl-4-methylfenol, dekamethylcyklopentasiloxan, dekamethyltetratasiloxan (L4), dodekamethylcyklohexasiloxan, dodekamethylpentasiloxan (L5), 1,1,1,3,5,5,5-heptamethyltrisiloxan, 1,1,1,3,5,5,5-heptamethyltrisiloxan modified with alkylene oxide, hexamethylcyklotrisiloxan, 1,1,3,3,5,5-hexamethyltrisiloxan, oktamethylcyklotetrasiloxan, oktamethyltrisiloxan (L3), etoxazol.","note_zh":"测定的分析物（分析物名称同捷克语原文）：PCB-6, PCB-7, PCB28, PCB31, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, heptachlor, methoxychlor, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, o,p-DDE, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-183, PBDE-209, DEHF, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, alachlor, chlorpyriphos, chlorpyriphos-methyl, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, trifluralin, propyzamide, chlorothalonil, triallate, ethofumesate, fluazifop-p-butyl, bifenthrine, deltamethrin, azoxystrobin, cypermethrin, α-cypermethrin, zeta-cypermethrin, beta-cyfluthrin, lambda-cyhalothrin, tau-fluvalinat, tefluthrin, musk keton, musk xylene, galaxolide (HHCB), tonalide (AHTN), 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, 1,2,4,5-tetrachlorbenzen, hexachlorbutadien (HCBD), chlordan, toxaphen, pentachlornitrobenzen, chlorinated alkanes C10-C13, chlorinated alkanes C14-C17, hexabromobenzen (HBB), pentabromoethylbenzen (PBEB), decabromodiphenylethane (DBDPE), bis(2-Ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), 1,2-bis(2,4,6-tribromophenoxy) ethane (BTBPE), 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (TBB), hexabromocyklododecane (HBCDD), dicofol, dimethylftalát (DMP), diethylftalát (DEP), dipropylftalát (DPP), diisobutylftalát (DiBP), dibutylftalát (DBP), butylbenzylftalát (BBzP), dipentylftalát (DPeP), dihexylftalát (DHP), dicyklohexylftalát (DCHP), bis(2-ethylhexyl)ftalát (DEHP), dioktylftalát (DOP), diisononylftalát (DiNP), diisodecylftalát (DIDP), naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenzo[a,h]anthracene, benzo[g,h,i]perylene, indeno[c,d]pyrene, 3,6-dimethylphenanthrene, perylene, benzo[a]fluorene, 1-methylnaphthalene, 4,4-dibromdiphenyl ether, hexabrombifenyl, bromopropylate, butralin, esfenvalerate, fenarimol, fenpropathrin, isofenphos, mirex, nitrofen, oxyfluorfen, permethrin, resmethrin, demeton, 2,4-D-1-butylester, 2,4-D-1-isobutylester, mirex, procymidone, propetamphos, quinalphos, tetrasul, tecnazene, vinclozolin, chlordecone (kepone), 4,4-Methylenebis(2,6-Di-Tert-butylphenol), 2-ethylhexyl-4-methoxycinnamát (Parsol SCX), 2,6-diterc-butyl-4-methylfenol, dekamethylcyklopentasiloxan, dekamethyltetratasiloxan (L4), dodekamethylcyklohexasiloxan, dodekamethylpentasiloxan (L5), 1,1,1,3,5,5,5-heptamethyltrisiloxan, 1,1,1,3,5,5,5-heptamethyltrisiloxan modified with alkylene oxide, hexamethylcyklotrisiloxan, 1,1,3,3,5,5-hexamethyltrisiloxan, oktamethylcyklotetrasiloxan, oktamethyltrisiloxan (L3), etoxazol.","note_cs":"PCB-6, PCB-7, PCB28, PCB31, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, heptachlor, methoxychlor, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, o,p-DDE, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-183, PBDE-209, DEHF, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, alachlor, chlorpyriphos, chlorpyriphos-methyl, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, trifluralin, propyzamide, chlorothalonil, triallate, ethofumesate, fluazifop-p-butyl, bifenthrine, deltamethrin, azoxystrobin, cypermethrin, α-cypermethrin, zeta-cypermethrin, beta-cyfluthrin, lambda-cyhalothrin, tau-fluvalinat, tefluthrin, musk keton, musk xylene, galaxolide (HHCB), tonalide (AHTN), 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, 1,2,4,5-tetrachlorbenzen, hexachlorbutadien (HCBD), chlordan, toxaphen, pentachlornitrobenzen, chlorované alkany C10-C13, chlorované alkany C14-C17, hexabromobenzen (HBB), pentabromoethylbenzen (PBEB), decabromodiphenylethane (DBDPE), bis(2-Ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), 1,2-bis(2,4,6-tribromophenoxy) ethane (BTBPE), 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (TBB), hexabromocyklododecane (HBCDD), dicofol, dimethylftalát (DMP), diethylftalát (DEP), dipropylftalát (DPP), diisobutylftalát (DiBP), dibutylftalát (DBP), butylbenzylftalát (BBzP), dipentylftalát (DPeP), dihexylftalát (DHP), dicyklohexylftalát (DCHP), bis(2-ethylhexyl)ftalát (DEHP), dioktylftalát (DOP), diisononylftalát (DiNP), diisodecylftalát (DIDP), naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenzo[a,h]anthracene, benzo[g,h,i]perylene, indeno[c,d]pyrene, 3,6-dimethylphenanthrene, perylene, benzo[a]fluorene, 1-methylnaphthalene, 4,4-dibromdiphenyl ether, hexabrombifenyl, bromopropylate, butralin, esfenvalerate, fenarimol, fenpropathrin, isofenphos, mirex, nitrofen, oxyfluorfen, permethrin, resmethrin, demeton, 2,4-D-1-butylester, 2,4-D-1-isobutylester, mirex, procymidone, propetamphos, quinalphos, tetrasul, tecnazene, vinclozolin, chlordecone (kepone), 4,4-Methylenebis(2,6-Di-Tert-butylphenol), 2-ethylhexyl-4-methoxycinnamát (Parsol SCX), 2,6-diterc-butyl-4-methylfenol, dekamethylcyklopentasiloxan, dekamethyltetratasiloxan (L4), dodekamethylcyklohexasiloxan, dodekamethylpentasiloxan (L5), 1,1,1,3,5,5,5-heptamethyltrisiloxan, 1,1,1,3,5,5,5-heptamethyltrisiloxan-modifikovaný alkylenoxidem, hexamethylcyklotrisiloxan, 1,1,3,3,5,5-hexamethyltrisiloxan, oktamethylcyklotetrasiloxan, oktamethyltrisiloxan (L3), etoxazol.","search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie PCB, pestycydów chloroorganicznych (OCP), polibromowanych difenyloeterów (PBDE), ftalanu bis(2-dietyloheksylu) (DEHP), związków piżmowych, pyretroidów i chloroalkanów C10 do C13 oraz C14 do C17 metodą GC/MS/MS, GC/EI-MSD, GC/NCI-MSD i obliczenie sum pestycydów i innych grup substancji z wartości zmierzonych Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení polychlorovaných bifenylů (PCB), organochlorových pesticidů (OCP), polybromovaných difenyletherů (PBDE), bis(2-diethylhexyl)ftalátu (DEHP), mošusových látek, pyrethroidů a chlorovaných alkanů C10 až C13 a C14 až C17 metodou GC/MS/MS, GC/EI-MSD, GC/NCI-MSD a výpočet sum pesticidů a dalších skupin látek z naměřených hodnot AO18A (ČSN EN ISO 6468; ČSN EN ISO 18856; ISO 12010) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie PCB, pestycydow chloroorganicznych (OCP), polibromowanych difenyloeterow (PBDE), ftalanu bis(2-dietyloheksylu) (DEHP), zwiazkow pizmowych, pyretroidow i chloroalkanow C10 do C13 oraz C14 do C17 metoda GC/MS/MS, GC/EI-MSD, GC/NCI-MSD i obliczenie sum pestycydow i innych grup substancji z wartosci zmierzonych Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni polychlorovanych bifenylu (PCB), organochlorovych pesticidu (OCP), polybromovanych difenyletheru (PBDE), bis(2-diethylhexyl)ftalatu (DEHP), mosusovych latek, pyrethroidu a chlorovanych alkanu C10 az C13 a C14 az C17 metodou GC/MS/MS, GC/EI-MSD, GC/NCI-MSD a vypocet sum pesticidu a dalsich skupin latek z namerenych hodnot AO18A (CSN EN ISO 6468; CSN EN ISO 18856; ISO 12010)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of PCB, organochlorine pesticides (OCP), polybrominated diphenyl ethers (PBDE), bis(2-diethylhexyl) phthalate (DEHP), musk compounds, pyrethroids and C10 to C13 and C14 to C17 chlorinated alkanes by GC/MS/MS, GC/EI-MSD, GC/NCI-MSD and calculation of sums of pesticides and other groups of substances from measured values AO18A (ČSN EN ISO 6468; ČSN EN ISO 18856; ISO 12010)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 GC/MS/MS、GC/EI-MSD、GC/NCI-MSD法测定PCB、有机氯农药（OCP）、多溴二苯醚（PBDE）、邻苯二甲酸双(2-二乙基己基)酯（DEHP）、麝香类、拟除虫菊酯及C10至C13和C14至C17氯化烷烃，并由测量值计算农药及其他类别物质总和 AO18A (ČSN EN ISO 6468; ČSN EN ISO 18856; ISO 12010)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"56038f7fd7af9aa80467cac8","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"71","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, dializat z próbnika pasywnego","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, dialysate from a passive sampler","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器透析液","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, dialyzát z pasivního vzorkovače","methodology":"Oznaczanie PCB, pestycydów chloroorganicznych (OCP), polibromowanych difenyloeterów (PBDE), ftalanu bis(2-dietyloheksylu) (DEHP), związków piżmowych, pyretroidów i chloroalkanów C10 do C13 oraz C14 do C17 metodą GC/MS/MS, GC/EI-MSD, GC/NCI-MSD i obliczenie sum pestycydów i innych grup substancji z wartości zmierzonych","methodology_en":"Determination of PCB, organochlorine pesticides (OCP), polybrominated diphenyl ethers (PBDE), bis(2-diethylhexyl) phthalate (DEHP), musk compounds, pyrethroids and C10 to C13 and C14 to C17 chlorinated alkanes by GC/MS/MS, GC/EI-MSD, GC/NCI-MSD and calculation of sums of pesticides and other groups of substances from measured values","methodology_zh":"GC/MS/MS、GC/EI-MSD、GC/NCI-MSD法测定PCB、有机氯农药（OCP）、多溴二苯醚（PBDE）、邻苯二甲酸双(2-二乙基己基)酯（DEHP）、麝香类、拟除虫菊酯及C10至C13和C14至C17氯化烷烃，并由测量值计算农药及其他类别物质总和","methodology_cs":"Stanovení polychlorovaných bifenylů (PCB), organochlorových pesticidů (OCP), polybromovaných difenyletherů (PBDE), bis(2-diethylhexyl)ftalátu (DEHP), mošusových látek, pyrethroidů a chlorovaných alkanů C10 až C13 a C14 až C17 metodou GC/MS/MS, GC/EI-MSD, GC/NCI-MSD a výpočet sum pesticidů a dalších skupin látek z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie PCB, pestycydów chloroorganicznych (OCP), polibromowanych difenyloeterów (PBDE), ftalanu bis(2-dietyloheksylu) (DEHP), związków piżmowych, pyretroidów i chloroalkanów C10 do C13 oraz C14 do C17 metodą GC/MS/MS, GC/EI-MSD, GC/NCI-MSD i obliczenie sum pestycydów i innych grup substancji z wartości zmierzonych","reference":"AO18B (ČSN EN ISO 18856; ČSN EN ISO 22032; ČSN EN 16167; ČSN EN ISO 18635)","norm_bases":["AO18B","ČSN EN ISO 18856","ČSN EN ISO 22032","ČSN EN 16167","ČSN EN ISO 18635"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): PCB-6, PCB-7, PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, heptachlor, methoxychlor, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, o,p-DDE, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-183, PBDE-209, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, alachlor, chlorpyriphos, chlorpyriphos-methyl, chlorfenvinphos, methyltriclosan, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, trifluralin, propyzamide, chlorothalonil, triallate, ethofumesate, fluazifop-p-butyl, bifenthrine, deltamethrin, azoxystrobin, cypermethrin, α-cypermethrin, zeta-cypermethrin, musk keton, musk xylene, galaxolide (HHCB), tonalide (AHTN), 1,2,4,5-tetrachlorbenzen; chlordan, toxaphen, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, pentachlornitrobenzen, hexachlorbutadien (HCBD), chloroalkany C10-C13, chloroalkany C14-C17, hexabromobenzen (HBB), pentabromoethylbenzen (PBEB), decabromodiphenylethane (DBDPE), bis(2-Ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), 1,2-bis(2,4,6-tribromophenoxy) ethane (BTBPE), 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (TBB), hexabromocyklododecane (HBCDD), dicofol, dimethylftalát (DMP), diethylftalát (DEP), dipropylftalát (DPP), diisobutylftalát (DiBP), dibutylftalát (DBP), butylbenzylftalát (BBzP), dipentylftalát (DPeP), dihexylftalát (DHP), dicyklohexylftalát (DCHP), bis(2-ethylhexyl)ftalát (DEHP), dioktylftalát (DOP), diisononylftalát (DiNP), diisodecylftalát (DIDP), naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren, 13C12-PCB-1, 13C12-PCB-1, 13C12-PCB-8, 13C12-PCB-37, 13C12-PCB-54, acenaphthene-D10, fluorene-D10, phenanthrene-D10, chrysene-D12, octachloronaphthalene, hexabrombifenyl, chlordecone (kepone), mirex, 2-ethylhexyl 4-methoxy cinnamat, beta-cyfluthrin, esfenvalerat, permethrin, resmethrin, tefluthrin, lambda-cyhalothrin, tau-fluvalinat.","note_en":"Determined analytes (analyte names as in the Czech original): PCB-6, PCB-7, PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, heptachlor, methoxychlor, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, o,p-DDE, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-183, PBDE-209, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, alachlor, chlorpyriphos, chlorpyriphos-methyl, chlorfenvinphos, methyltriclosan, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, trifluralin, propyzamide, chlorothalonil, triallate, ethofumesate, fluazifop-p-butyl, bifenthrine, deltamethrin, azoxystrobin, cypermethrin, α-cypermethrin, zeta-cypermethrin, musk keton, musk xylene, galaxolide (HHCB), tonalide (AHTN), 1,2,4,5-tetrachlorbenzen; chlordan, toxaphen, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, pentachlornitrobenzen, hexachlorbutadien (HCBD), chlorinated alkanes C10-C13, chlorinated alkanes C14-C17, hexabromobenzen (HBB), pentabromoethylbenzen (PBEB), decabromodiphenylethane (DBDPE), bis(2-Ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), 1,2-bis(2,4,6-tribromophenoxy) ethane (BTBPE), 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (TBB), hexabromocyklododecane (HBCDD), dicofol, dimethylftalát (DMP), diethylftalát (DEP), dipropylftalát (DPP), diisobutylftalát (DiBP), dibutylftalát (DBP), butylbenzylftalát (BBzP), dipentylftalát (DPeP), dihexylftalát (DHP), dicyklohexylftalát (DCHP), bis(2-ethylhexyl)ftalát (DEHP), dioktylftalát (DOP), diisononylftalát (DiNP), diisodecylftalát (DIDP), naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren, 13C12-PCB-1, 13C12-PCB-1, 13C12-PCB-8, 13C12-PCB-37, 13C12-PCB-54, acenaphthene-D10, fluorene-D10, phenanthrene-D10, chrysene-D12, octachloronaphthalene, hexabrombifenyl, chlordecone (kepone), mirex, 2-ethylhexyl 4-methoxy cinnamat, beta-cyfluthrin, esfenvalerat, permethrin, resmethrin, tefluthrin, lambda-cyhalothrin, tau-fluvalinat.","note_zh":"测定的分析物（分析物名称同捷克语原文）：PCB-6, PCB-7, PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, heptachlor, methoxychlor, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, o,p-DDE, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-183, PBDE-209, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, alachlor, chlorpyriphos, chlorpyriphos-methyl, chlorfenvinphos, methyltriclosan, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, trifluralin, propyzamide, chlorothalonil, triallate, ethofumesate, fluazifop-p-butyl, bifenthrine, deltamethrin, azoxystrobin, cypermethrin, α-cypermethrin, zeta-cypermethrin, musk keton, musk xylene, galaxolide (HHCB), tonalide (AHTN), 1,2,4,5-tetrachlorbenzen; chlordan, toxaphen, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, pentachlornitrobenzen, hexachlorbutadien (HCBD), chlorinated alkanes C10-C13, chlorinated alkanes C14-C17, hexabromobenzen (HBB), pentabromoethylbenzen (PBEB), decabromodiphenylethane (DBDPE), bis(2-Ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), 1,2-bis(2,4,6-tribromophenoxy) ethane (BTBPE), 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (TBB), hexabromocyklododecane (HBCDD), dicofol, dimethylftalát (DMP), diethylftalát (DEP), dipropylftalát (DPP), diisobutylftalát (DiBP), dibutylftalát (DBP), butylbenzylftalát (BBzP), dipentylftalát (DPeP), dihexylftalát (DHP), dicyklohexylftalát (DCHP), bis(2-ethylhexyl)ftalát (DEHP), dioktylftalát (DOP), diisononylftalát (DiNP), diisodecylftalát (DIDP), naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren, 13C12-PCB-1, 13C12-PCB-1, 13C12-PCB-8, 13C12-PCB-37, 13C12-PCB-54, acenaphthene-D10, fluorene-D10, phenanthrene-D10, chrysene-D12, octachloronaphthalene, hexabrombifenyl, chlordecone (kepone), mirex, 2-ethylhexyl 4-methoxy cinnamat, beta-cyfluthrin, esfenvalerat, permethrin, resmethrin, tefluthrin, lambda-cyhalothrin, tau-fluvalinat.","note_cs":"PCB-6, PCB-7, PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, heptachlor, methoxychlor, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, o,p-DDE, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-183, PBDE-209, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, alachlor, chlorpyriphos, chlorpyriphos-methyl, chlorfenvinphos, methyltriclosan, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, trifluralin, propyzamide, chlorothalonil, triallate, ethofumesate, fluazifop-p-butyl, bifenthrine, deltamethrin, azoxystrobin, cypermethrin, α-cypermethrin, zeta-cypermethrin, musk keton, musk xylene, galaxolide (HHCB), tonalide (AHTN), 1,2,4,5-tetrachlorbenzen; chlordan, toxaphen, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, pentachlornitrobenzen, hexachlorbutadien (HCBD), chlorované alkany C10-C13, chlorované alkany C14-C17, hexabromobenzen (HBB), pentabromoethylbenzen (PBEB), decabromodiphenylethane (DBDPE), bis(2-Ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), 1,2-bis(2,4,6-tribromophenoxy) ethane (BTBPE), 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (TBB), hexabromocyklododecane (HBCDD), dicofol, dimethylftalát (DMP), diethylftalát (DEP), dipropylftalát (DPP), diisobutylftalát (DiBP), dibutylftalát (DBP), butylbenzylftalát (BBzP), dipentylftalát (DPeP), dihexylftalát (DHP), dicyklohexylftalát (DCHP), bis(2-ethylhexyl)ftalát (DEHP), dioktylftalát (DOP), diisononylftalát (DiNP), diisodecylftalát (DIDP), naftalen, acenaftylen, acenaften, fluoren, fenanthren, anthracen, fluoranthen, pyren, benzo/a/anthracen, chrysen, benzo/b/fluorathen, benzo/k/fluoranthen, benzo/a/pyren, dibenzo/ah/anthracen, benzo/ghi/perylen, indeno/cd/pyren, 13C12-PCB-1, 13C12-PCB-1, 13C12-PCB-8, 13C12-PCB-37, 13C12-PCB-54, acenaphthene-D10, fluorene-D10, phenanthrene-D10, chrysene-D12, octachloronaphthalene, hexabrombifenyl, chlordecone (kepone), mirex, 2-ethylhexyl 4-methoxy cinnamat, beta-cyfluthrin, esfenvalerat, permethrin, resmethrin, tefluthrin, lambda-cyhalothrin, tau-fluvalinat.","search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, dializat z próbnika pasywnego Oznaczanie PCB, pestycydów chloroorganicznych (OCP), polibromowanych difenyloeterów (PBDE), ftalanu bis(2-dietyloheksylu) (DEHP), związków piżmowych, pyretroidów i chloroalkanów C10 do C13 oraz C14 do C17 metodą GC/MS/MS, GC/EI-MSD, GC/NCI-MSD i obliczenie sum pestycydów i innych grup substancji z wartości zmierzonych Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, dialyzát z pasivního vzorkovače Stanovení polychlorovaných bifenylů (PCB), organochlorových pesticidů (OCP), polybromovaných difenyletherů (PBDE), bis(2-diethylhexyl)ftalátu (DEHP), mošusových látek, pyrethroidů a chlorovaných alkanů C10 až C13 a C14 až C17 metodou GC/MS/MS, GC/EI-MSD, GC/NCI-MSD a výpočet sum pesticidů a dalších skupin látek z naměřených hodnot AO18B (ČSN EN ISO 18856; ČSN EN ISO 22032; ČSN EN 16167; ČSN EN ISO 18635) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale, dializat z probnika pasywnego Oznaczanie PCB, pestycydow chloroorganicznych (OCP), polibromowanych difenyloeterow (PBDE), ftalanu bis(2-dietyloheksylu) (DEHP), zwiazkow pizmowych, pyretroidow i chloroalkanow C10 do C13 oraz C14 do C17 metoda GC/MS/MS, GC/EI-MSD, GC/NCI-MSD i obliczenie sum pestycydow i innych grup substancji z wartosci zmierzonych Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady, dialyzat z pasivniho vzorkovace Stanoveni polychlorovanych bifenylu (PCB), organochlorovych pesticidu (OCP), polybromovanych difenyletheru (PBDE), bis(2-diethylhexyl)ftalatu (DEHP), mosusovych latek, pyrethroidu a chlorovanych alkanu C10 az C13 a C14 az C17 metodou GC/MS/MS, GC/EI-MSD, GC/NCI-MSD a vypocet sum pesticidu a dalsich skupin latek z namerenych hodnot AO18B (CSN EN ISO 18856; CSN EN ISO 22032; CSN EN 16167; CSN EN ISO 18635)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, dialysate from a passive sampler Determination of PCB, organochlorine pesticides (OCP), polybrominated diphenyl ethers (PBDE), bis(2-diethylhexyl) phthalate (DEHP), musk compounds, pyrethroids and C10 to C13 and C14 to C17 chlorinated alkanes by GC/MS/MS, GC/EI-MSD, GC/NCI-MSD and calculation of sums of pesticides and other groups of substances from measured values AO18B (ČSN EN ISO 18856; ČSN EN ISO 22032; ČSN EN 16167; ČSN EN ISO 18635)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器透析液 GC/MS/MS、GC/EI-MSD、GC/NCI-MSD法测定PCB、有机氯农药（OCP）、多溴二苯醚（PBDE）、邻苯二甲酸双(2-二乙基己基)酯（DEHP）、麝香类、拟除虫菊酯及C10至C13和C14至C17氯化烷烃，并由测量值计算农药及其他类别物质总和 AO18B (ČSN EN ISO 18856; ČSN EN ISO 22032; ČSN EN 16167; ČSN EN ISO 18635)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b82e65c160070fd43dffa11d","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"72","test_object":"Materiał zwierzęcy i roślinny","test_object_en":"Animal and plant material","test_object_zh":"动物和植物材料","test_object_cs":"Živočišný a rostlinný materiál","methodology":"Oznaczanie PCB, pestycydów chloroorganicznych (OCP), polibromowanych difenyloeterów (PBDE), ftalanu bis(2-dietyloheksylu) (DEHP), związków piżmowych, pyretroidów i chloroalkanów C10 do C13 oraz C14 do C17 metodą GC/MS/MS, GC/EI-MSD, GC/NCI-MSD i obliczenie sum pestycydów i innych grup substancji z wartości zmierzonych","methodology_en":"Determination of PCB, organochlorine pesticides (OCP), polybrominated diphenyl ethers (PBDE), bis(2-diethylhexyl) phthalate (DEHP), musk compounds, pyrethroids and C10 to C13 and C14 to C17 chlorinated alkanes by GC/MS/MS, GC/EI-MSD, GC/NCI-MSD and calculation of sums of pesticides and other groups of substances from measured values","methodology_zh":"GC/MS/MS、GC/EI-MSD、GC/NCI-MSD法测定PCB、有机氯农药（OCP）、多溴二苯醚（PBDE）、邻苯二甲酸双(2-二乙基己基)酯（DEHP）、麝香类、拟除虫菊酯及C10至C13和C14至C17氯化烷烃，并由测量值计算农药及其他类别物质总和","methodology_cs":"Stanovení polychlorovaných bifenylů (PCB), organochlorových pesticidů (OCP), polybromovaných difenyletherů (PBDE), bis(2-diethylhexyl)ftalátu (DEHP), mošusových látek, pyrethroidů a chlorovaných alkanů C10 až C13 a C14 až C17, metodou GC/MS/MS, GC/EI-MSD, GC/NCI-MSD a výpočet sum pesticidů a dalších skupin látek z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie PCB, pestycydów chloroorganicznych (OCP), polibromowanych difenyloeterów (PBDE), ftalanu bis(2-dietyloheksylu) (DEHP), związków piżmowych, pyretroidów i chloroalkanów C10 do C13 oraz C14 do C17 metodą GC/MS/MS, GC/EI-MSD, GC/NCI-MSD i obliczenie sum pestycydów i innych grup substancji z wartości zmierzonych","reference":"AO18C (ČSN EN ISO 18856; EN ISO 22032; ISO 12010)","norm_bases":["AO18C","ČSN EN ISO 18856","EN ISO 22032","ISO 12010"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality (nazwy analitów jak w oryginale czeskim): PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, heptachlor, methoxychlor, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, o,p-DDE, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-183, PBDE-209, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, alachlor, chlorpyriphos, chlorpyriphos-methyl, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, trifluralin, propyzamide, chlorethalonil, triallate, ethofumesate, fluazifop-p-butyl, bifenthrine, deltamethrin, azoxystrobin, cypermethrin, α-cypermethrin, zeta-cypermethrin, musk keton, musk xylene, galaxolide (HHCB), tonalide (AHTN), 1,2,4,5-tetrachlorbenzen, chlordan, toxaphen, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, pentachlornitrobenzen, hexachlorbutadien (HCBD), chloroalkany C10-C13, chloroalkany C14-C17., DEHP.","note_en":"Determined analytes (analyte names as in the Czech original): PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, heptachlor, methoxychlor, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, o,p-DDE, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-183, PBDE-209, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, alachlor, chlorpyriphos, chlorpyriphos-methyl, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, trifluralin, propyzamide, chlorethalonil, triallate, ethofumesate, fluazifop-p-butyl, bifenthrine, deltamethrin, azoxystrobin, cypermethrin, α-cypermethrin, zeta-cypermethrin, musk keton, musk xylene, galaxolide (HHCB), tonalide (AHTN), 1,2,4,5-tetrachlorbenzen, chlordan, toxaphen, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, pentachlornitrobenzen, hexachlorbutadien (HCBD), chlorinated alkanes C10-C13, chlorinated alkanes C14-C17., DEHP.","note_zh":"测定的分析物（分析物名称同捷克语原文）：PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, heptachlor, methoxychlor, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, o,p-DDE, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-183, PBDE-209, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, alachlor, chlorpyriphos, chlorpyriphos-methyl, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, trifluralin, propyzamide, chlorethalonil, triallate, ethofumesate, fluazifop-p-butyl, bifenthrine, deltamethrin, azoxystrobin, cypermethrin, α-cypermethrin, zeta-cypermethrin, musk keton, musk xylene, galaxolide (HHCB), tonalide (AHTN), 1,2,4,5-tetrachlorbenzen, chlordan, toxaphen, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, pentachlornitrobenzen, hexachlorbutadien (HCBD), chlorinated alkanes C10-C13, chlorinated alkanes C14-C17., DEHP.","note_cs":"PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, PCB194, HCB, α-HCH, β-HCH, γ-HCH, δ-HCH, ε-HCH, heptachlor, methoxychlor, p,p‘-DDE, o,p-DDD, p,p‘-DDD, o,p-DDT, p,p‘-DDT, o,p-DDE, PBDE-28, PBDE-47, PBDE-99, PBDE-100, PBDE153, PBDE-154, PBDE-183, PBDE-209, α-endosulfan, β-endosulfan, endrin, dieldrin, aldrin, isodrin, alachlor, chlorpyriphos, chlorpyriphos-methyl, pentachlorbenzen, oktachlorstyren, cis-heptachlorepoxid, trans-heptachlorepoxid, trifluralin, propyzamide, chlorethalonil, triallate, ethofumesate, fluazifop-p-butyl, bifenthrine, deltamethrin, azoxystrobin, cypermethrin, α-cypermethrin, zeta-cypermethrin, musk keton, musk xylene, galaxolide (HHCB), tonalide (AHTN), 1,2,4,5-tetrachlorbenzen, chlordan, toxaphen, 1,3,5-trichlorbenzen, 1,2,4-trichlorbenzen, 1,2,3-trichlorbenzen, pentachlornitrobenzen, hexachlorbutadien (HCBD), chlorované alkany C10-C13, chlorované alkany C14-C17., DEHP.","search_text":"Materiał zwierzęcy i roślinny Oznaczanie PCB, pestycydów chloroorganicznych (OCP), polibromowanych difenyloeterów (PBDE), ftalanu bis(2-dietyloheksylu) (DEHP), związków piżmowych, pyretroidów i chloroalkanów C10 do C13 oraz C14 do C17 metodą GC/MS/MS, GC/EI-MSD, GC/NCI-MSD i obliczenie sum pestycydów i innych grup substancji z wartości zmierzonych Živočišný a rostlinný materiál Stanovení polychlorovaných bifenylů (PCB), organochlorových pesticidů (OCP), polybromovaných difenyletherů (PBDE), bis(2-diethylhexyl)ftalátu (DEHP), mošusových látek, pyrethroidů a chlorovaných alkanů C10 až C13 a C14 až C17, metodou GC/MS/MS, GC/EI-MSD, GC/NCI-MSD a výpočet sum pesticidů a dalších skupin látek z naměřených hodnot AO18C (ČSN EN ISO 18856; EN ISO 22032; ISO 12010) Material zwierzecy i roslinny Oznaczanie PCB, pestycydow chloroorganicznych (OCP), polibromowanych difenyloeterow (PBDE), ftalanu bis(2-dietyloheksylu) (DEHP), zwiazkow pizmowych, pyretroidow i chloroalkanow C10 do C13 oraz C14 do C17 metoda GC/MS/MS, GC/EI-MSD, GC/NCI-MSD i obliczenie sum pestycydow i innych grup substancji z wartosci zmierzonych Zivocisny a rostlinny material Stanoveni polychlorovanych bifenylu (PCB), organochlorovych pesticidu (OCP), polybromovanych difenyletheru (PBDE), bis(2-diethylhexyl)ftalatu (DEHP), mosusovych latek, pyrethroidu a chlorovanych alkanu C10 az C13 a C14 az C17, metodou GC/MS/MS, GC/EI-MSD, GC/NCI-MSD a vypocet sum pesticidu a dalsich skupin latek z namerenych hodnot AO18C (CSN EN ISO 18856; EN ISO 22032; ISO 12010)","search_en":"Animal and plant material Determination of PCB, organochlorine pesticides (OCP), polybrominated diphenyl ethers (PBDE), bis(2-diethylhexyl) phthalate (DEHP), musk compounds, pyrethroids and C10 to C13 and C14 to C17 chlorinated alkanes by GC/MS/MS, GC/EI-MSD, GC/NCI-MSD and calculation of sums of pesticides and other groups of substances from measured values AO18C (ČSN EN ISO 18856; EN ISO 22032; ISO 12010)","search_zh":"动物和植物材料 GC/MS/MS、GC/EI-MSD、GC/NCI-MSD法测定PCB、有机氯农药（OCP）、多溴二苯醚（PBDE）、邻苯二甲酸双(2-二乙基己基)酯（DEHP）、麝香类、拟除虫菊酯及C10至C13和C14至C17氯化烷烃，并由测量值计算农药及其他类别物质总和 AO18C (ČSN EN ISO 18856; EN ISO 22032; ISO 12010)","categories":["environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"36ca6f11b2b601e754693b1a","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"73","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody technologiczne i morskie, wyciągi","test_object_en":"Drinking, surface, ground, waste, process and sea water, leachates","test_object_zh":"饮用水、地表水、地下水、废水、工艺用水和海水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní, technologické a mořské, výluhy","methodology":"Oznaczanie związków cynoorganicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych","methodology_en":"Determination of organotin compounds by GC/MSD and calculation of their sum from measured values","methodology_zh":"GC/MSD法测定有机锡化合物并由测量值计算其总和","methodology_cs":"Stanovení organocíničitých sloučenin metodou GC/MSD a výpočet sumy organocíničitých sloučenin z naměřených hodnot","parameters":[{"name":"Monobutylocyna (MBT)","range":""},{"name":"dibutylocyna (DBT)","range":""},{"name":"tributylocyna (TBT)","range":""},{"name":"trifenylocyna (TPhT)","range":""},{"name":"tetrabutylocyna (TTBT)","range":""},{"name":"tricykloheksylocyna","range":""},{"name":"monofenylocyna","range":""},{"name":"difenylocyna","range":""}],"parameters_en":[{"name":"Monobutyltin (MBT)","range":""},{"name":"dibutyltin (DBT)","range":""},{"name":"tributyltin (TBT)","range":""},{"name":"triphenyltin (TPhT)","range":""},{"name":"tetrabutyltin (TTBT)","range":""},{"name":"tricyclohexyltin","range":""},{"name":"monophenyltin","range":""},{"name":"diphenyltin","range":""}],"parameters_zh":[{"name":"一丁基锡（MBT）","range":""},{"name":"二丁基锡（DBT）","range":""},{"name":"三丁基锡（TBT）","range":""},{"name":"三苯基锡（TPhT）","range":""},{"name":"四丁基锡（TTBT）","range":""},{"name":"三环己基锡","range":""},{"name":"一苯基锡","range":""},{"name":"二苯基锡","range":""}],"parameters_cs":[{"name":"Monobutylcín (MBT)","range":""},{"name":"dibutylcín (DBT)","range":""},{"name":"tributylcín (TBT)","range":""},{"name":"trifenylcín (TPhT)","range":""},{"name":"tetrabutylcín (TTBT)","range":""},{"name":"tricyklohexylcín","range":""},{"name":"monofenylcín","range":""},{"name":"difenylcín","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie związków cynoorganicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych\nZakres:\nMonobutylocyna (MBT)\ndibutylocyna (DBT)\ntributylocyna (TBT)\ntrifenylocyna (TPhT)\ntetrabutylocyna (TTBT)\ntricykloheksylocyna\nmonofenylocyna\ndifenylocyna","reference":"AO19A (ČSN EN ISO 17353)","norm_bases":["AO19A","ČSN EN ISO 17353"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki, wody technologiczne i morskie, wyciągi Oznaczanie związków cynoorganicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych Monobutylocyna (MBT)  dibutylocyna (DBT)  tributylocyna (TBT)  trifenylocyna (TPhT)  tetrabutylocyna (TTBT)  tricykloheksylocyna  monofenylocyna  difenylocyna  Vody pitné, povrchové, podzemní, odpadní, technologické a mořské, výluhy Stanovení organocíničitých sloučenin metodou GC/MSD a výpočet sumy organocíničitých sloučenin z naměřených hodnot Monobutylcín (MBT)  dibutylcín (DBT)  tributylcín (TBT)  trifenylcín (TPhT)  tetrabutylcín (TTBT)  tricyklohexylcín  monofenylcín  difenylcín  AO19A (ČSN EN ISO 17353) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki, wody technologiczne i morskie, wyciagi Oznaczanie zwiazkow cynoorganicznych metoda GC/MSD i obliczenie ich sumy z wartosci zmierzonych Monobutylocyna (MBT)  dibutylocyna (DBT)  tributylocyna (TBT)  trifenylocyna (TPhT)  tetrabutylocyna (TTBT)  tricykloheksylocyna  monofenylocyna  difenylocyna  Vody pitne, povrchove, podzemni, odpadni, technologicke a morske, vyluhy Stanoveni organocinicitych sloucenin metodou GC/MSD a vypocet sumy organocinicitych sloucenin z namerenych hodnot Monobutylcin (MBT)  dibutylcin (DBT)  tributylcin (TBT)  trifenylcin (TPhT)  tetrabutylcin (TTBT)  tricyklohexylcin  monofenylcin  difenylcin  AO19A (CSN EN ISO 17353)","search_en":"Drinking, surface, ground, waste, process and sea water, leachates Determination of organotin compounds by GC/MSD and calculation of their sum from measured values Monobutyltin (MBT)  dibutyltin (DBT)  tributyltin (TBT)  triphenyltin (TPhT)  tetrabutyltin (TTBT)  tricyclohexyltin  monophenyltin  diphenyltin  AO19A (ČSN EN ISO 17353)","search_zh":"饮用水、地表水、地下水、废水、工艺用水和海水、浸出液 GC/MSD法测定有机锡化合物并由测量值计算其总和 一丁基锡（MBT）  二丁基锡（DBT）  三丁基锡（TBT）  三苯基锡（TPhT）  四丁基锡（TTBT）  三环己基锡  一苯基锡  二苯基锡  AO19A (ČSN EN ISO 17353)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1a7c5dbf9e9585207798c468","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"74","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, dializat z próbnika pasywnego","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, dialysate from a passive sampler","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器透析液","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, dialyzát z pasivního vzorkovače","methodology":"Oznaczanie związków cynoorganicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych","methodology_en":"Determination of organotin compounds by GC/MSD and calculation of their sum from measured values","methodology_zh":"GC/MSD法测定有机锡化合物并由测量值计算其总和","methodology_cs":"Stanovení organocíničitých sloučenin metodou GC/MSD a výpočet sumy organocíničitých sloučenin z naměřených hodnot","parameters":[{"name":"Monobutylocyna (MBT)","range":""},{"name":"dibutylocyna (DBT)","range":""},{"name":"tributylocyna (TBT)","range":""},{"name":"trifenylocyna (TPhT)","range":""},{"name":"tetrabutylocyna (TTBT)","range":""},{"name":"tricykloheksylocyna","range":""},{"name":"monofenylocyna","range":""},{"name":"difenylocyna","range":""}],"parameters_en":[{"name":"Monobutyltin (MBT)","range":""},{"name":"dibutyltin (DBT)","range":""},{"name":"tributyltin (TBT)","range":""},{"name":"triphenyltin (TPhT)","range":""},{"name":"tetrabutyltin (TTBT)","range":""},{"name":"tricyclohexyltin","range":""},{"name":"monophenyltin","range":""},{"name":"diphenyltin","range":""}],"parameters_zh":[{"name":"一丁基锡（MBT）","range":""},{"name":"二丁基锡（DBT）","range":""},{"name":"三丁基锡（TBT）","range":""},{"name":"三苯基锡（TPhT）","range":""},{"name":"四丁基锡（TTBT）","range":""},{"name":"三环己基锡","range":""},{"name":"一苯基锡","range":""},{"name":"二苯基锡","range":""}],"parameters_cs":[{"name":"Monobutylcín (MBT)","range":""},{"name":"dibutylcín (DBT)","range":""},{"name":"tributylcín (TBT)","range":""},{"name":"trifenylcín (TPhT)","range":""},{"name":"tetrabutylcín (TTBT)","range":""},{"name":"tricyklohexylcín","range":""},{"name":"monofenylcín","range":""},{"name":"difenylcín","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie związków cynoorganicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych\nZakres:\nMonobutylocyna (MBT)\ndibutylocyna (DBT)\ntributylocyna (TBT)\ntrifenylocyna (TPhT)\ntetrabutylocyna (TTBT)\ntricykloheksylocyna\nmonofenylocyna\ndifenylocyna","reference":"AO19B (ČSN EN ISO 23161)","norm_bases":["AO19B","ČSN EN ISO 23161"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe, dializat z próbnika pasywnego Oznaczanie związków cynoorganicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych Monobutylocyna (MBT)  dibutylocyna (DBT)  tributylocyna (TBT)  trifenylocyna (TPhT)  tetrabutylocyna (TTBT)  tricykloheksylocyna  monofenylocyna  difenylocyna  Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady, dialyzát z pasivního vzorkovače Stanovení organocíničitých sloučenin metodou GC/MSD a výpočet sumy organocíničitých sloučenin z naměřených hodnot Monobutylcín (MBT)  dibutylcín (DBT)  tributylcín (TBT)  trifenylcín (TPhT)  tetrabutylcín (TTBT)  tricyklohexylcín  monofenylcín  difenylcín  AO19B (ČSN EN ISO 23161) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale, dializat z probnika pasywnego Oznaczanie zwiazkow cynoorganicznych metoda GC/MSD i obliczenie ich sumy z wartosci zmierzonych Monobutylocyna (MBT)  dibutylocyna (DBT)  tributylocyna (TBT)  trifenylocyna (TPhT)  tetrabutylocyna (TTBT)  tricykloheksylocyna  monofenylocyna  difenylocyna  Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady, dialyzat z pasivniho vzorkovace Stanoveni organocinicitych sloucenin metodou GC/MSD a vypocet sumy organocinicitych sloucenin z namerenych hodnot Monobutylcin (MBT)  dibutylcin (DBT)  tributylcin (TBT)  trifenylcin (TPhT)  tetrabutylcin (TTBT)  tricyklohexylcin  monofenylcin  difenylcin  AO19B (CSN EN ISO 23161)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste, dialysate from a passive sampler Determination of organotin compounds by GC/MSD and calculation of their sum from measured values Monobutyltin (MBT)  dibutyltin (DBT)  tributyltin (TBT)  triphenyltin (TPhT)  tetrabutyltin (TTBT)  tricyclohexyltin  monophenyltin  diphenyltin  AO19B (ČSN EN ISO 23161)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物、被动采样器透析液 GC/MSD法测定有机锡化合物并由测量值计算其总和 一丁基锡（MBT）  二丁基锡（DBT）  三丁基锡（TBT）  三苯基锡（TPhT）  四丁基锡（TTBT）  三环己基锡  一苯基锡  二苯基锡  AO19B (ČSN EN ISO 23161)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cbd3754099cc9fca2f8d9711","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"75","test_object":"Materiał zwierzęcy i roślinny","test_object_en":"Animal and plant material","test_object_zh":"动物和植物材料","test_object_cs":"Živočišný a rostlinný materiál","methodology":"Oznaczanie związków cynoorganicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych","methodology_en":"Determination of organotin compounds by GC/MSD and calculation of their sum from measured values","methodology_zh":"GC/MSD法测定有机锡化合物并由测量值计算其总和","methodology_cs":"Stanovení organocíničitých sloučenin metodou GC/MSD a výpočet sumy organocíničitých sloučenin z naměřených hodnot","parameters":[{"name":"Monobutylocyna (MBT)","range":""},{"name":"dibutylocyna (DBT)","range":""},{"name":"tributylocyna (TBT)","range":""},{"name":"trifenylocyna (TPhT)","range":""},{"name":"tetrabutylocyna (TTBT)","range":""},{"name":"tricykloheksylocyna","range":""},{"name":"monofenylocyna","range":""},{"name":"difenylocyna","range":""}],"parameters_en":[{"name":"Monobutyltin (MBT)","range":""},{"name":"dibutyltin (DBT)","range":""},{"name":"tributyltin (TBT)","range":""},{"name":"triphenyltin (TPhT)","range":""},{"name":"tetrabutyltin (TTBT)","range":""},{"name":"tricyclohexyltin","range":""},{"name":"monophenyltin","range":""},{"name":"diphenyltin","range":""}],"parameters_zh":[{"name":"一丁基锡（MBT）","range":""},{"name":"二丁基锡（DBT）","range":""},{"name":"三丁基锡（TBT）","range":""},{"name":"三苯基锡（TPhT）","range":""},{"name":"四丁基锡（TTBT）","range":""},{"name":"三环己基锡","range":""},{"name":"一苯基锡","range":""},{"name":"二苯基锡","range":""}],"parameters_cs":[{"name":"Monobutylcín (MBT)","range":""},{"name":"dibutylcín (DBT)","range":""},{"name":"tributylcín (TBT)","range":""},{"name":"trifenylcín (TPhT)","range":""},{"name":"tetrabutylcín (TTBT)","range":""},{"name":"tricyklohexylcín","range":""},{"name":"monofenylcín","range":""},{"name":"difenylcín","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie związków cynoorganicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych\nZakres:\nMonobutylocyna (MBT)\ndibutylocyna (DBT)\ntributylocyna (TBT)\ntrifenylocyna (TPhT)\ntetrabutylocyna (TTBT)\ntricykloheksylocyna\nmonofenylocyna\ndifenylocyna","reference":"AO19C (ČSN EN ISO 23161)","norm_bases":["AO19C","ČSN EN ISO 23161"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał zwierzęcy i roślinny Oznaczanie związków cynoorganicznych metodą GC/MSD i obliczenie ich sumy z wartości zmierzonych Monobutylocyna (MBT)  dibutylocyna (DBT)  tributylocyna (TBT)  trifenylocyna (TPhT)  tetrabutylocyna (TTBT)  tricykloheksylocyna  monofenylocyna  difenylocyna  Živočišný a rostlinný materiál Stanovení organocíničitých sloučenin metodou GC/MSD a výpočet sumy organocíničitých sloučenin z naměřených hodnot Monobutylcín (MBT)  dibutylcín (DBT)  tributylcín (TBT)  trifenylcín (TPhT)  tetrabutylcín (TTBT)  tricyklohexylcín  monofenylcín  difenylcín  AO19C (ČSN EN ISO 23161) Material zwierzecy i roslinny Oznaczanie zwiazkow cynoorganicznych metoda GC/MSD i obliczenie ich sumy z wartosci zmierzonych Monobutylocyna (MBT)  dibutylocyna (DBT)  tributylocyna (TBT)  trifenylocyna (TPhT)  tetrabutylocyna (TTBT)  tricykloheksylocyna  monofenylocyna  difenylocyna  Zivocisny a rostlinny material Stanoveni organocinicitych sloucenin metodou GC/MSD a vypocet sumy organocinicitych sloucenin z namerenych hodnot Monobutylcin (MBT)  dibutylcin (DBT)  tributylcin (TBT)  trifenylcin (TPhT)  tetrabutylcin (TTBT)  tricyklohexylcin  monofenylcin  difenylcin  AO19C (CSN EN ISO 23161)","search_en":"Animal and plant material Determination of organotin compounds by GC/MSD and calculation of their sum from measured values Monobutyltin (MBT)  dibutyltin (DBT)  tributyltin (TBT)  triphenyltin (TPhT)  tetrabutyltin (TTBT)  tricyclohexyltin  monophenyltin  diphenyltin  AO19C (ČSN EN ISO 23161)","search_zh":"动物和植物材料 GC/MSD法测定有机锡化合物并由测量值计算其总和 一丁基锡（MBT）  二丁基锡（DBT）  三丁基锡（TBT）  三苯基锡（TPhT）  四丁基锡（TTBT）  三环己基锡  一苯基锡  二苯基锡  AO19C (ČSN EN ISO 23161)","categories":["environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9944712d532fef9ebe759fb4","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"76","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie parakwatu i dikwatu metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych","methodology_en":"Determination of paraquat and diquat by LC/MS/MS and calculation of the sum of pesticides from measured values","methodology_zh":"LC/MS/MS法测定百草枯和敌草快并由测量值计算农药总和","methodology_cs":"Stanovení paraquatu a diquatu metodou LC/MS/MS a výpočet sumy pesticidů z naměřených hodnot","parameters":[{"name":"Parakwat","range":""},{"name":"dikwat","range":""},{"name":"chlormekwat","range":""},{"name":"mepikwat","range":""}],"parameters_en":[{"name":"Paraquat","range":""},{"name":"diquat","range":""},{"name":"chlormequat","range":""},{"name":"mepiquat","range":""}],"parameters_zh":[{"name":"百草枯","range":""},{"name":"敌草快","range":""},{"name":"矮壮素","range":""},{"name":"甲哌鎓","range":""}],"parameters_cs":[{"name":"Paraquat","range":""},{"name":"diquat","range":""},{"name":"chlormequat","range":""},{"name":"mepiquat","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie parakwatu i dikwatu metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych\nZakres:\nParakwat\ndikwat\nchlormekwat\nmepikwat","reference":"AO20A (LCGC Eur. 2004, 17(11a), s. 51-52)","norm_bases":["AO20A","LCGC Eur. 2004, 17(11a), s. 51-52"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie parakwatu i dikwatu metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych Parakwat  dikwat  chlormekwat  mepikwat  Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení paraquatu a diquatu metodou LC/MS/MS a výpočet sumy pesticidů z naměřených hodnot Paraquat  diquat  chlormequat  mepiquat  AO20A (LCGC Eur. 2004, 17(11a), s. 51-52) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie parakwatu i dikwatu metoda LC/MS/MS i obliczenie sumy pestycydow z wartosci zmierzonych Parakwat  dikwat  chlormekwat  mepikwat  Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni paraquatu a diquatu metodou LC/MS/MS a vypocet sumy pesticidu z namerenych hodnot Paraquat  diquat  chlormequat  mepiquat  AO20A (LCGC Eur. 2004, 17(11a), s. 51-52)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of paraquat and diquat by LC/MS/MS and calculation of the sum of pesticides from measured values Paraquat  diquat  chlormequat  mepiquat  AO20A (LCGC Eur. 2004, 17(11a), s. 51-52)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 LC/MS/MS法测定百草枯和敌草快并由测量值计算农药总和 百草枯  敌草快  矮壮素  甲哌鎓  AO20A (LCGC Eur. 2004, 17(11a), s. 51-52)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1f7dd5756f815da3ae7ca5cd","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"77","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady","methodology":"Oznaczanie parakwatu i dikwatu metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych","methodology_en":"Determination of paraquat and diquat by LC/MS/MS and calculation of the sum of pesticides from measured values","methodology_zh":"LC/MS/MS法测定百草枯和敌草快并由测量值计算农药总和","methodology_cs":"Stanovení paraquatu a diquatu metodou LC/MS/MS a výpočet sumy pesticidů z naměřených hodnot","parameters":[{"name":"Parakwat","range":""},{"name":"dikwat","range":""},{"name":"chlormekwat","range":""},{"name":"mepikwat","range":""}],"parameters_en":[{"name":"Paraquat","range":""},{"name":"diquat","range":""},{"name":"chlormequat","range":""},{"name":"mepiquat","range":""}],"parameters_zh":[{"name":"百草枯","range":""},{"name":"敌草快","range":""},{"name":"矮壮素","range":""},{"name":"甲哌鎓","range":""}],"parameters_cs":[{"name":"Paraquat","range":""},{"name":"diquat","range":""},{"name":"chlormequat","range":""},{"name":"mepiquat","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie parakwatu i dikwatu metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych\nZakres:\nParakwat\ndikwat\nchlormekwat\nmepikwat","reference":"AO20B (J. Chromatogr. A, 1196-1197, 2008, s. 110-116)","norm_bases":["AO20B","J. Chromatogr. A, 1196-1197, 2008, s. 110-116"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe Oznaczanie parakwatu i dikwatu metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych Parakwat  dikwat  chlormekwat  mepikwat  Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady Stanovení paraquatu a diquatu metodou LC/MS/MS a výpočet sumy pesticidů z naměřených hodnot Paraquat  diquat  chlormequat  mepiquat  AO20B (J. Chromatogr. A, 1196-1197, 2008, s. 110-116) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale Oznaczanie parakwatu i dikwatu metoda LC/MS/MS i obliczenie sumy pestycydow z wartosci zmierzonych Parakwat  dikwat  chlormekwat  mepikwat  Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady Stanoveni paraquatu a diquatu metodou LC/MS/MS a vypocet sumy pesticidu z namerenych hodnot Paraquat  diquat  chlormequat  mepiquat  AO20B (J. Chromatogr. A, 1196-1197, 2008, s. 110-116)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste Determination of paraquat and diquat by LC/MS/MS and calculation of the sum of pesticides from measured values Paraquat  diquat  chlormequat  mepiquat  AO20B (J. Chromatogr. A, 1196-1197, 2008, s. 110-116)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物 LC/MS/MS法测定百草枯和敌草快并由测量值计算农药总和 百草枯  敌草快  矮壮素  甲哌鎓  AO20B (J. Chromatogr. A, 1196-1197, 2008, s. 110-116)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"09e67a2d5aea44edfd3e9982","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"78","test_object":"Materiał zwierzęcy i roślinny","test_object_en":"Animal and plant material","test_object_zh":"动物和植物材料","test_object_cs":"Živočišný a rostlinný materiál","methodology":"Oznaczanie parakwatu i dikwatu metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych","methodology_en":"Determination of paraquat and diquat by LC/MS/MS and calculation of the sum of pesticides from measured values","methodology_zh":"LC/MS/MS法测定百草枯和敌草快并由测量值计算农药总和","methodology_cs":"Stanovení paraquatu a diquatu metodou LC/MS/MS a výpočet sumy pesticidů z naměřených hodnot","parameters":[{"name":"Parakwat","range":""},{"name":"dikwat","range":""},{"name":"chlormekwat","range":""},{"name":"mepikwat","range":""}],"parameters_en":[{"name":"Paraquat","range":""},{"name":"diquat","range":""},{"name":"chlormequat","range":""},{"name":"mepiquat","range":""}],"parameters_zh":[{"name":"百草枯","range":""},{"name":"敌草快","range":""},{"name":"矮壮素","range":""},{"name":"甲哌鎓","range":""}],"parameters_cs":[{"name":"Paraquat","range":""},{"name":"diquat","range":""},{"name":"chlormequat","range":""},{"name":"mepiquat","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie parakwatu i dikwatu metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych\nZakres:\nParakwat\ndikwat\nchlormekwat\nmepikwat","reference":"AO20C (J. Chromatogr. A, 1196-1197, 2008, s. 110-116)","norm_bases":["AO20C","J. Chromatogr. A, 1196-1197, 2008, s. 110-116"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał zwierzęcy i roślinny Oznaczanie parakwatu i dikwatu metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych Parakwat  dikwat  chlormekwat  mepikwat  Živočišný a rostlinný materiál Stanovení paraquatu a diquatu metodou LC/MS/MS a výpočet sumy pesticidů z naměřených hodnot Paraquat  diquat  chlormequat  mepiquat  AO20C (J. Chromatogr. A, 1196-1197, 2008, s. 110-116) Material zwierzecy i roslinny Oznaczanie parakwatu i dikwatu metoda LC/MS/MS i obliczenie sumy pestycydow z wartosci zmierzonych Parakwat  dikwat  chlormekwat  mepikwat  Zivocisny a rostlinny material Stanoveni paraquatu a diquatu metodou LC/MS/MS a vypocet sumy pesticidu z namerenych hodnot Paraquat  diquat  chlormequat  mepiquat  AO20C (J. Chromatogr. A, 1196-1197, 2008, s. 110-116)","search_en":"Animal and plant material Determination of paraquat and diquat by LC/MS/MS and calculation of the sum of pesticides from measured values Paraquat  diquat  chlormequat  mepiquat  AO20C (J. Chromatogr. A, 1196-1197, 2008, s. 110-116)","search_zh":"动物和植物材料 LC/MS/MS法测定百草枯和敌草快并由测量值计算农药总和 百草枯  敌草快  矮壮素  甲哌鎓  AO20C (J. Chromatogr. A, 1196-1197, 2008, s. 110-116)","categories":["environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"88944b8e4c0d08d850b72155","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"79","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie glifosatu, glufosynatu i kwasu (aminometylo)fosfonowego (AMPA) metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych","methodology_en":"Determination of glyphosate, glufosinate and (aminomethyl)phosphonic acid (AMPA) by LC/MS/MS and calculation of the sum of pesticides from measured values","methodology_zh":"LC/MS/MS法测定草甘膦、草铵膦和氨甲基膦酸（AMPA）并由测量值计算农药总和","methodology_cs":"Stanovení glyfosátu, glufosinátu a (aminomethyl)fosfonové kyseliny (AMPA) metodou LC/MS/MS a výpočet sumy pesticidů z naměřených hodnot","parameters":[{"name":"Glifosat","range":""},{"name":"glufosynat","range":""},{"name":"AMPA (kwas aminometylofosfonowy)","range":""}],"parameters_en":[{"name":"Glyphosate","range":""},{"name":"glufosinate","range":""},{"name":"AMPA (aminomethylphosphonic acid)","range":""}],"parameters_zh":[{"name":"草甘膦","range":""},{"name":"草铵膦","range":""},{"name":"氨甲基膦酸（AMPA）","range":""}],"parameters_cs":[{"name":"Glyphosat","range":""},{"name":"glufosinát","range":""},{"name":"AMPA","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie glifosatu, glufosynatu i kwasu (aminometylo)fosfonowego (AMPA) metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych\nZakres:\nGlifosat\nglufosynat\nAMPA (kwas aminometylofosfonowy)","reference":"AO21A (ČSN ISO 21458; Anal. Bioanal. Chem., 391, J. Chromatogr. A, 1081, 2005, s. 145-155)","norm_bases":["AO21A","ČSN ISO 21458","Anal. Bioanal. Chem., 391","J. Chromatogr. A, 1081, 2005, s. 145-155"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie glifosatu, glufosynatu i kwasu (aminometylo)fosfonowego (AMPA) metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych Glifosat  glufosynat  AMPA (kwas aminometylofosfonowy)  Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení glyfosátu, glufosinátu a (aminomethyl)fosfonové kyseliny (AMPA) metodou LC/MS/MS a výpočet sumy pesticidů z naměřených hodnot Glyphosat  glufosinát  AMPA  AO21A (ČSN ISO 21458; Anal. Bioanal. Chem., 391, J. Chromatogr. A, 1081, 2005, s. 145-155) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie glifosatu, glufosynatu i kwasu (aminometylo)fosfonowego (AMPA) metoda LC/MS/MS i obliczenie sumy pestycydow z wartosci zmierzonych Glifosat  glufosynat  AMPA (kwas aminometylofosfonowy)  Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni glyfosatu, glufosinatu a (aminomethyl)fosfonove kyseliny (AMPA) metodou LC/MS/MS a vypocet sumy pesticidu z namerenych hodnot Glyphosat  glufosinat  AMPA  AO21A (CSN ISO 21458; Anal. Bioanal. Chem., 391, J. Chromatogr. A, 1081, 2005, s. 145-155)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of glyphosate, glufosinate and (aminomethyl)phosphonic acid (AMPA) by LC/MS/MS and calculation of the sum of pesticides from measured values Glyphosate  glufosinate  AMPA (aminomethylphosphonic acid)  AO21A (ČSN ISO 21458; Anal. Bioanal. Chem., 391, J. Chromatogr. A, 1081, 2005, s. 145-155)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 LC/MS/MS法测定草甘膦、草铵膦和氨甲基膦酸（AMPA）并由测量值计算农药总和 草甘膦  草铵膦  氨甲基膦酸（AMPA）  AO21A (ČSN ISO 21458; Anal. Bioanal. Chem., 391, J. Chromatogr. A, 1081, 2005, s. 145-155)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0bafd9d4e0f992b3864b24d5","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"80","test_object":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe","test_object_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste","test_object_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物","test_object_cs":"Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady","methodology":"Oznaczanie glifosatu i kwasu (aminometylo)fosfonowego (AMPA) metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych","methodology_en":"Determination of glyphosate and (aminomethyl)phosphonic acid (AMPA) by LC/MS/MS and calculation of the sum of pesticides from measured values","methodology_zh":"LC/MS/MS法测定草甘膦和氨甲基膦酸（AMPA）并由测量值计算农药总和","methodology_cs":"Stanovení glyfosátu a (aminomethyl)fosfonové kyseliny (AMPA) metodou LC/MS/MS a výpočet sumy pesticidů z naměřených hodnot","parameters":[{"name":"Glifosat","range":""},{"name":"AMPA (kwas aminometylofosfonowy)","range":""}],"parameters_en":[{"name":"Glyphosate","range":""},{"name":"AMPA (aminomethylphosphonic acid)","range":""}],"parameters_zh":[{"name":"草甘膦","range":""},{"name":"氨甲基膦酸（AMPA）","range":""}],"parameters_cs":[{"name":"Glyphosat","range":""},{"name":"AMPA","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie glifosatu i kwasu (aminometylo)fosfonowego (AMPA) metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych\nZakres:\nGlifosat\nAMPA (kwas aminometylofosfonowy)","reference":"AO21B (ČSN ISO 21458; J. Chromatogr. A, 1081, 2005, s. 145-155)","norm_bases":["AO21B","ČSN ISO 21458","J. Chromatogr. A, 1081, 2005, s. 145-155"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadające, odpady stałe Oznaczanie glifosatu i kwasu (aminometylo)fosfonowego (AMPA) metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych Glifosat  AMPA (kwas aminometylofosfonowy)  Půdy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelné plaveniny, pevné odpady Stanovení glyfosátu a (aminomethyl)fosfonové kyseliny (AMPA) metodou LC/MS/MS a výpočet sumy pesticidů z naměřených hodnot Glyphosat  AMPA  AO21B (ČSN ISO 21458; J. Chromatogr. A, 1081, 2005, s. 145-155) Gleby, grunty, osady denne, osady, zawiesiny, zawiesiny opadajace, odpady stale Oznaczanie glifosatu i kwasu (aminometylo)fosfonowego (AMPA) metoda LC/MS/MS i obliczenie sumy pestycydow z wartosci zmierzonych Glifosat  AMPA (kwas aminometylofosfonowy)  Pudy, zeminy, sedimenty, kaly, plaveniny, sedimentovatelne plaveniny, pevne odpady Stanoveni glyfosatu a (aminomethyl)fosfonove kyseliny (AMPA) metodou LC/MS/MS a vypocet sumy pesticidu z namerenych hodnot Glyphosat  AMPA  AO21B (CSN ISO 21458; J. Chromatogr. A, 1081, 2005, s. 145-155)","search_en":"Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste Determination of glyphosate and (aminomethyl)phosphonic acid (AMPA) by LC/MS/MS and calculation of the sum of pesticides from measured values Glyphosate  AMPA (aminomethylphosphonic acid)  AO21B (ČSN ISO 21458; J. Chromatogr. A, 1081, 2005, s. 145-155)","search_zh":"土壤、土、沉积物、污泥、悬移质、可沉降悬移质、固体废物 LC/MS/MS法测定草甘膦和氨甲基膦酸（AMPA）并由测量值计算农药总和 草甘膦  氨甲基膦酸（AMPA）  AO21B (ČSN ISO 21458; J. Chromatogr. A, 1081, 2005, s. 145-155)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"003f832c5b68d05ef70cfdc0","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"81","test_object":"Materiał zwierzęcy i roślinny","test_object_en":"Animal and plant material","test_object_zh":"动物和植物材料","test_object_cs":"Živočišný a rostlinný materiál","methodology":"Oznaczanie glifosatu i kwasu (aminometylo)fosfonowego (AMPA) metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych","methodology_en":"Determination of glyphosate and (aminomethyl)phosphonic acid (AMPA) by LC/MS/MS and calculation of the sum of pesticides from measured values","methodology_zh":"LC/MS/MS法测定草甘膦和氨甲基膦酸（AMPA）并由测量值计算农药总和","methodology_cs":"Stanovení glyfosátu a (aminomethyl)fosfonové kyseliny (AMPA) metodou LC/MS/MS a výpočet sumy pesticidů z naměřených hodnot","parameters":[{"name":"Glifosat","range":""},{"name":"AMPA (kwas aminometylofosfonowy)","range":""}],"parameters_en":[{"name":"Glyphosate","range":""},{"name":"AMPA (aminomethylphosphonic acid)","range":""}],"parameters_zh":[{"name":"草甘膦","range":""},{"name":"氨甲基膦酸（AMPA）","range":""}],"parameters_cs":[{"name":"Glyphosat","range":""},{"name":"AMPA","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie glifosatu i kwasu (aminometylo)fosfonowego (AMPA) metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych\nZakres:\nGlifosat\nAMPA (kwas aminometylofosfonowy)","reference":"AO21C (J. Chromatogr. A, 1081, 2005, s. 145-155)","norm_bases":["AO21C","J. Chromatogr. A, 1081, 2005, s. 145-155"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał zwierzęcy i roślinny Oznaczanie glifosatu i kwasu (aminometylo)fosfonowego (AMPA) metodą LC/MS/MS i obliczenie sumy pestycydów z wartości zmierzonych Glifosat  AMPA (kwas aminometylofosfonowy)  Živočišný a rostlinný materiál Stanovení glyfosátu a (aminomethyl)fosfonové kyseliny (AMPA) metodou LC/MS/MS a výpočet sumy pesticidů z naměřených hodnot Glyphosat  AMPA  AO21C (J. Chromatogr. A, 1081, 2005, s. 145-155) Material zwierzecy i roslinny Oznaczanie glifosatu i kwasu (aminometylo)fosfonowego (AMPA) metoda LC/MS/MS i obliczenie sumy pestycydow z wartosci zmierzonych Glifosat  AMPA (kwas aminometylofosfonowy)  Zivocisny a rostlinny material Stanoveni glyfosatu a (aminomethyl)fosfonove kyseliny (AMPA) metodou LC/MS/MS a vypocet sumy pesticidu z namerenych hodnot Glyphosat  AMPA  AO21C (J. Chromatogr. A, 1081, 2005, s. 145-155)","search_en":"Animal and plant material Determination of glyphosate and (aminomethyl)phosphonic acid (AMPA) by LC/MS/MS and calculation of the sum of pesticides from measured values Glyphosate  AMPA (aminomethylphosphonic acid)  AO21C (J. Chromatogr. A, 1081, 2005, s. 145-155)","search_zh":"动物和植物材料 LC/MS/MS法测定草甘膦和氨甲基膦酸（AMPA）并由测量值计算农药总和 草甘膦  氨甲基膦酸（AMPA）  AO21C (J. Chromatogr. A, 1081, 2005, s. 145-155)","categories":["environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4679fdab6df233bef334b617","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"82","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie całkowitej aktywności objętościowej alfa metodą scyntylacyjną i obliczenie całkowitej dawki orientacyjnej z wartości zmierzonych","methodology_en":"Determination of gross alpha volume activity by the scintillation method and calculation of the total indicative dose from measured values","methodology_zh":"闪烁法测定总α体积活度并由测量值计算总指示剂量","methodology_cs":"Stanovení celkové objemové aktivity alfa scintilační metodou a výpočet celkové indikativní dávky z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie całkowitej aktywności objętościowej alfa metodą scyntylacyjną i obliczenie całkowitej dawki orientacyjnej z wartości zmierzonych","reference":"AR01A (ČSN 75 7611; Doporučení SÚJB „Měření a hodnocení obsahu přírodních radionuklidů ve vodě dodávané k veřejnému zásobování pitnou vodou Rev.1, SÚJB 2012)","norm_bases":["AR01A","ČSN 75 7611","Doporučení SÚJB „Měření a hodnocení obsahu přírodních radionuklidů ve vodě dodávané k veřejnému zásobování pitnou vodou Rev.1, SÚJB 2012"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie całkowitej aktywności objętościowej alfa metodą scyntylacyjną i obliczenie całkowitej dawki orientacyjnej z wartości zmierzonych Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení celkové objemové aktivity alfa scintilační metodou a výpočet celkové indikativní dávky z naměřených hodnot AR01A (ČSN 75 7611; Doporučení SÚJB „Měření a hodnocení obsahu přírodních radionuklidů ve vodě dodávané k veřejnému zásobování pitnou vodou Rev.1, SÚJB 2012) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie calkowitej aktywnosci objetosciowej alfa metoda scyntylacyjna i obliczenie calkowitej dawki orientacyjnej z wartosci zmierzonych Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni celkove objemove aktivity alfa scintilacni metodou a vypocet celkove indikativni davky z namerenych hodnot AR01A (CSN 75 7611; Doporuceni SUJB „Mereni a hodnoceni obsahu prirodnich radionuklidu ve vode dodavane k verejnemu zasobovani pitnou vodou Rev.1, SUJB 2012)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of gross alpha volume activity by the scintillation method and calculation of the total indicative dose from measured values AR01A (ČSN 75 7611; Doporučení SÚJB „Měření a hodnocení obsahu přírodních radionuklidů ve vodě dodávané k veřejnému zásobování pitnou vodou Rev.1, SÚJB 2012)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 闪烁法测定总α体积活度并由测量值计算总指示剂量 AR01A (ČSN 75 7611; Doporučení SÚJB „Měření a hodnocení obsahu přírodních radionuklidů ve vodě dodávané k veřejnému zásobování pitnou vodou Rev.1, SÚJB 2012)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"49efd9c88e2a1ecf72375e39","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"83","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie całkowitej aktywności objętościowej beta proporcjonalną sondą gazową","methodology_en":"Determination of gross beta volume activity with a gas proportional probe","methodology_zh":"气体正比探头测定总β体积活度","methodology_cs":"Stanovení celkové objemové aktivity beta proporcionální plynovou sondou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie całkowitej aktywności objętościowej beta proporcjonalną sondą gazową","reference":"AR02A (ČSN 75 7612)","norm_bases":["AR02A","ČSN 75 7612"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie całkowitej aktywności objętościowej beta proporcjonalną sondą gazową Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení celkové objemové aktivity beta proporcionální plynovou sondou AR02A (ČSN 75 7612) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie calkowitej aktywnosci objetosciowej beta proporcjonalna sonda gazowa Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni celkove objemove aktivity beta proporcionalni plynovou sondou AR02A (CSN 75 7612)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of gross beta volume activity with a gas proportional probe AR02A (ČSN 75 7612)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 气体正比探头测定总β体积活度 AR02A (ČSN 75 7612)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":82,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ca2be381c9f26e7645caeb0f","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"84","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi","test_object_en":"Drinking, surface, ground, waste and process water, leachates","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy","methodology":"Oznaczanie aktywności objętościowej radu-226 i radonu-222 metodą emanometryczną","methodology_en":"Determination of radium-226 and radon-222 volume activity by emanometry","methodology_zh":"射气法测定镭-226和氡-222体积活度","methodology_cs":"Stanovení objemové aktivity radia-226 a radonu-222 emanometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie aktywności objętościowej radu-226 i radonu-222 metodą emanometryczną","reference":"AR04A (ČSN 75 7623; ČSN 75 7624)","norm_bases":["AR04A","ČSN 75 7623","ČSN 75 7624"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi Oznaczanie aktywności objętościowej radu-226 i radonu-222 metodą emanometryczną Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy Stanovení objemové aktivity radia-226 a radonu-222 emanometricky AR04A (ČSN 75 7623; ČSN 75 7624) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi Oznaczanie aktywnosci objetosciowej radu-226 i radonu-222 metoda emanometryczna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy Stanoveni objemove aktivity radia-226 a radonu-222 emanometricky AR04A (CSN 75 7623; CSN 75 7624)","search_en":"Drinking, surface, ground, waste and process water, leachates Determination of radium-226 and radon-222 volume activity by emanometry AR04A (ČSN 75 7623; ČSN 75 7624)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液 射气法测定镭-226和氡-222体积活度 AR04A (ČSN 75 7623; ČSN 75 7624)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":83,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eef257e103a7858d0195d101","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"85","test_object":"Wody przeznaczone do spożycia, powierzchniowe, surowe i uzdatnione","test_object_en":"Drinking, surface, raw and treated water","test_object_zh":"饮用水、地表水、原水和处理水","test_object_cs":"Vody pitné, povrchové, surové a upravené","methodology":"Oznaczanie biosestonu, abiosestonu, fitoplanktonu i biomasy objętościowej fitoplanktonu metodą mikroskopową","methodology_en":"Determination of bioseston, abioseston, phytoplankton and phytoplankton volume biomass by microscopy","methodology_zh":"显微镜法测定生物悬浮物、非生物悬浮物、浮游植物及浮游植物体积生物量","methodology_cs":"Stanovení biosestonu, abiosestonu, fytoplanktonu a objemové biomasy fytoplanktonu mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biosestonu, abiosestonu, fitoplanktonu i biomasy objętościowej fitoplanktonu metodą mikroskopową","reference":"BB01A (ČSN 75 7712; ČSN 75 7713; ČSN EN 15204; Heteša, J., Marvan, P.: Metodika odběru a zpracování vzorků fytoplanktonu tekoucích vod, VÚV, 2006)","norm_bases":["BB01A","ČSN 75 7712","ČSN 75 7713","ČSN EN 15204","Heteša, J., Marvan, P.: Metodika odběru a zpracování vzorků fytoplanktonu tekoucích vod, VÚV, 2006"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, surowe i uzdatnione Oznaczanie biosestonu, abiosestonu, fitoplanktonu i biomasy objętościowej fitoplanktonu metodą mikroskopową Vody pitné, povrchové, surové a upravené Stanovení biosestonu, abiosestonu, fytoplanktonu a objemové biomasy fytoplanktonu mikroskopicky BB01A (ČSN 75 7712; ČSN 75 7713; ČSN EN 15204; Heteša, J., Marvan, P.: Metodika odběru a zpracování vzorků fytoplanktonu tekoucích vod, VÚV, 2006) Wody przeznaczone do spozycia, powierzchniowe, surowe i uzdatnione Oznaczanie biosestonu, abiosestonu, fitoplanktonu i biomasy objetosciowej fitoplanktonu metoda mikroskopowa Vody pitne, povrchove, surove a upravene Stanoveni biosestonu, abiosestonu, fytoplanktonu a objemove biomasy fytoplanktonu mikroskopicky BB01A (CSN 75 7712; CSN 75 7713; CSN EN 15204; Hetesa, J., Marvan, P.: Metodika odberu a zpracovani vzorku fytoplanktonu tekoucich vod, VUV, 2006)","search_en":"Drinking, surface, raw and treated water Determination of bioseston, abioseston, phytoplankton and phytoplankton volume biomass by microscopy BB01A (ČSN 75 7712; ČSN 75 7713; ČSN EN 15204; Heteša, J., Marvan, P.: Metodika odběru a zpracování vzorků fytoplanktonu tekoucích vod, VÚV, 2006)","search_zh":"饮用水、地表水、原水和处理水 显微镜法测定生物悬浮物、非生物悬浮物、浮游植物及浮游植物体积生物量 BB01A (ČSN 75 7712; ČSN 75 7713; ČSN EN 15204; Heteša, J., Marvan, P.: Metodika odběru a zpracování vzorků fytoplanktonu tekoucích vod, VÚV, 2006)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":84,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"866d3de383b6aa5bfd260021","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"86","test_object":"Zespoły organizmów wodnych","test_object_en":"Communities of aquatic organisms","test_object_zh":"水生生物群落","test_object_cs":"Společenstva vodních organismů","methodology":"Oznaczanie indeksu saprobowości","methodology_en":"Determination of the saprobic index","methodology_zh":"污水生物指数测定","methodology_cs":"Stanovení saprobního indexu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie indeksu saprobowości","reference":"BB02A (ČSN 75 7716)","norm_bases":["BB02A","ČSN 75 7716"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zespoły organizmów wodnych Oznaczanie indeksu saprobowości Společenstva vodních organismů Stanovení saprobního indexu BB02A (ČSN 75 7716) Zespoly organizmow wodnych Oznaczanie indeksu saprobowosci Spolecenstva vodnich organismu Stanoveni saprobniho indexu BB02A (CSN 75 7716)","search_en":"Communities of aquatic organisms Determination of the saprobic index BB02A (ČSN 75 7716)","search_zh":"水生生物群落 污水生物指数测定 BB02A (ČSN 75 7716)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":85,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"29d9604138e99b8e96139dd8","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"87","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Vody povrchové","methodology":"Oznaczanie stężenia chlorofilu a i produktów jego rozkładu metodą spektrofotometryczną","methodology_en":"Determination of chlorophyll a and its degradation products by spectrophotometry","methodology_zh":"分光光度法测定叶绿素a及其降解产物浓度","methodology_cs":"Stanovení koncentrace chlorofylu-a a jeho rozkladných produktů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia chlorofilu a i produktów jego rozkładu metodą spektrofotometryczną","reference":"BB03A (ČSN ISO 10260)","norm_bases":["BB03A","ČSN ISO 10260"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Oznaczanie stężenia chlorofilu a i produktów jego rozkładu metodą spektrofotometryczną Vody povrchové Stanovení koncentrace chlorofylu-a a jeho rozkladných produktů spektrofotometricky BB03A (ČSN ISO 10260) Wody powierzchniowe Oznaczanie stezenia chlorofilu a i produktow jego rozkladu metoda spektrofotometryczna Vody povrchove Stanoveni koncentrace chlorofylu-a a jeho rozkladnych produktu spektrofotometricky BB03A (CSN ISO 10260)","search_en":"Surface water Determination of chlorophyll a and its degradation products by spectrophotometry BB03A (ČSN ISO 10260)","search_zh":"地表水 分光光度法测定叶绿素a及其降解产物浓度 BB03A (ČSN ISO 10260)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":86,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7fc3e284784d3d5e4c720211","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"88","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Vody povrchové","methodology":"Oznaczanie stężenia chlorofilu a i produktów jego rozkładu metodą fluorymetryczną","methodology_en":"Determination of chlorophyll a and its degradation products by fluorometry","methodology_zh":"荧光法测定叶绿素a及其降解产物浓度","methodology_cs":"Stanovení koncentrace chlorofylu-a a jeho rozkladných produktů fluorometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia chlorofilu a i produktów jego rozkładu metodą fluorymetryczną","reference":"BB07A (EPA 445.0, 1997)","norm_bases":["BB07A","EPA 445.0, 1997"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Oznaczanie stężenia chlorofilu a i produktów jego rozkładu metodą fluorymetryczną Vody povrchové Stanovení koncentrace chlorofylu-a a jeho rozkladných produktů fluorometricky BB07A (EPA 445.0, 1997) Wody powierzchniowe Oznaczanie stezenia chlorofilu a i produktow jego rozkladu metoda fluorymetryczna Vody povrchove Stanoveni koncentrace chlorofylu-a a jeho rozkladnych produktu fluorometricky BB07A (EPA 445.0, 1997)","search_en":"Surface water Determination of chlorophyll a and its degradation products by fluorometry BB07A (EPA 445.0, 1997)","search_zh":"地表水 荧光法测定叶绿素a及其降解产物浓度 BB07A (EPA 445.0, 1997)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":87,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"254235742685e7c7e63ee26d","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"89","test_object":"Wody przeznaczone do spożycia, surowe i uzdatnione","test_object_en":"Drinking, raw and treated water","test_object_zh":"饮用水、原水和处理水","test_object_cs":"Vody pitné, surové a upravené","methodology":"Oznaczanie żywych i martwych organizmów autotroficznych metodą epifluorescencyjną","methodology_en":"Determination of live and dead autotrophic organisms by epifluorescence","methodology_zh":"落射荧光法测定活的和死的自养生物","methodology_cs":"Stanovení živých a mrtvých autotrofních organismů epifluorescenčně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie żywych i martwych organizmów autotroficznych metodą epifluorescencyjną","reference":"BB09A (ČSN 75 7712)","norm_bases":["BB09A","ČSN 75 7712"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, surowe i uzdatnione Oznaczanie żywych i martwych organizmów autotroficznych metodą epifluorescencyjną Vody pitné, surové a upravené Stanovení živých a mrtvých autotrofních organismů epifluorescenčně BB09A (ČSN 75 7712) Wody przeznaczone do spozycia, surowe i uzdatnione Oznaczanie zywych i martwych organizmow autotroficznych metoda epifluorescencyjna Vody pitne, surove a upravene Stanoveni zivych a mrtvych autotrofnich organismu epifluorescencne BB09A (CSN 75 7712)","search_en":"Drinking, raw and treated water Determination of live and dead autotrophic organisms by epifluorescence BB09A (ČSN 75 7712)","search_zh":"饮用水、原水和处理水 落射荧光法测定活的和死的自养生物 BB09A (ČSN 75 7712)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":88,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"58d8125e9e27919628360896","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"90","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Vody povrchové","methodology":"Oznaczanie biomasy (suchej masy) zooplanktonu metodą wagową","methodology_en":"Determination of zooplankton biomass (dry matter) by gravimetry","methodology_zh":"重量法测定浮游动物生物量（干物质）","methodology_cs":"Stanovení biomasy (sušiny) zooplanktonu gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biomasy (suchej masy) zooplanktonu metodą wagową","reference":"BB11A (ČSN 75 7346; Straškraba, M. a kol.: Metodika sledování a hodnocení jakosti vody vodárenských nádrží, HBÚ ČSAV, 1992)","norm_bases":["BB11A","ČSN 75 7346","Straškraba, M. a kol.: Metodika sledování a hodnocení jakosti vody vodárenských nádrží, HBÚ ČSAV, 1992"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Oznaczanie biomasy (suchej masy) zooplanktonu metodą wagową Vody povrchové Stanovení biomasy (sušiny) zooplanktonu gravimetricky BB11A (ČSN 75 7346; Straškraba, M. a kol.: Metodika sledování a hodnocení jakosti vody vodárenských nádrží, HBÚ ČSAV, 1992) Wody powierzchniowe Oznaczanie biomasy (suchej masy) zooplanktonu metoda wagowa Vody povrchove Stanoveni biomasy (susiny) zooplanktonu gravimetricky BB11A (CSN 75 7346; Straskraba, M. a kol.: Metodika sledovani a hodnoceni jakosti vody vodarenskych nadrzi, HBU CSAV, 1992)","search_en":"Surface water Determination of zooplankton biomass (dry matter) by gravimetry BB11A (ČSN 75 7346; Straškraba, M. a kol.: Metodika sledování a hodnocení jakosti vody vodárenských nádrží, HBÚ ČSAV, 1992)","search_zh":"地表水 重量法测定浮游动物生物量（干物质） BB11A (ČSN 75 7346; Straškraba, M. a kol.: Metodika sledování a hodnocení jakosti vody vodárenských nádrží, HBÚ ČSAV, 1992)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":89,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0ab78f80684bc0bfcf9d92f4","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"91","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Vody povrchové","methodology":"Oznaczanie biomasy objętościowej organizmów autotroficznych metodą mikroskopową z analizą obrazu","methodology_en":"Determination of volume biomass of autotrophic organisms by microscopy with image analysis","methodology_zh":"显微图像分析法测定自养生物体积生物量","methodology_cs":"Stanovení objemové biomasy autotrofních organismů, mikroskopicky pomocí analýzy obrazu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biomasy objętościowej organizmów autotroficznych metodą mikroskopową z analizą obrazu","reference":"BB12A (Manual LUCIA, verze 4.6 a NIS-Elements, verze 3.2x)","norm_bases":["BB12A","Manual LUCIA, verze 4.6 a NIS-Elements, verze 3.2x"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Oznaczanie biomasy objętościowej organizmów autotroficznych metodą mikroskopową z analizą obrazu Vody povrchové Stanovení objemové biomasy autotrofních organismů, mikroskopicky pomocí analýzy obrazu BB12A (Manual LUCIA, verze 4.6 a NIS-Elements, verze 3.2x) Wody powierzchniowe Oznaczanie biomasy objetosciowej organizmow autotroficznych metoda mikroskopowa z analiza obrazu Vody povrchove Stanoveni objemove biomasy autotrofnich organismu, mikroskopicky pomoci analyzy obrazu BB12A (Manual LUCIA, verze 4.6 a NIS-Elements, verze 3.2x)","search_en":"Surface water Determination of volume biomass of autotrophic organisms by microscopy with image analysis BB12A (Manual LUCIA, verze 4.6 a NIS-Elements, verze 3.2x)","search_zh":"地表水 显微图像分析法测定自养生物体积生物量 BB12A (Manual LUCIA, verze 4.6 a NIS-Elements, verze 3.2x)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":90,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a587b695d28d0b704d5e5ab5","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"92","test_object":"Osad czynny","test_object_en":"Activated sludge","test_object_zh":"活性污泥","test_object_cs":"Aktivovaný kal","methodology":"Analiza mikroskopowa i ocena biologiczna osadu czynnego","methodology_en":"Microscopic analysis and biological assessment of activated sludge","methodology_zh":"活性污泥显微分析和生物学评价","methodology_cs":"Mikroskopický rozbor a biologické hodnocení aktivovaného kalu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Analiza mikroskopowa i ocena biologiczna osadu czynnego","reference":"BB13B (Technické doporučení II-E-22, Hydroprojekt, 2003)","norm_bases":["BB13B","Technické doporučení II-E-22, Hydroprojekt, 2003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad czynny Analiza mikroskopowa i ocena biologiczna osadu czynnego Aktivovaný kal Mikroskopický rozbor a biologické hodnocení aktivovaného kalu BB13B (Technické doporučení II-E-22, Hydroprojekt, 2003) Osad czynny Analiza mikroskopowa i ocena biologiczna osadu czynnego Aktivovany kal Mikroskopicky rozbor a biologicke hodnoceni aktivovaneho kalu BB13B (Technicke doporuceni II-E-22, Hydroprojekt, 2003)","search_en":"Activated sludge Microscopic analysis and biological assessment of activated sludge BB13B (Technické doporučení II-E-22, Hydroprojekt, 2003)","search_zh":"活性污泥 活性污泥显微分析和生物学评价 BB13B (Technické doporučení II-E-22, Hydroprojekt, 2003)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":91,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fc37e49303f7442783c8aa8f","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"93","test_object":"Wody powierzchniowe, surowe i uzdatnione, rozmyte osady denne","test_object_en":"Surface, raw and treated water, suspended sediments","test_object_zh":"地表水、原水和处理水、悬浮沉积物","test_object_cs":"Vody povrchové, surové a upravené, rozplavené sedimenty","methodology":"Oznaczanie sinic planktonowych metodą mikroskopową","methodology_en":"Determination of planktonic cyanobacteria by microscopy","methodology_zh":"显微镜法测定浮游蓝藻","methodology_cs":"Stanovení planktonních sinic mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie sinic planktonowych metodą mikroskopową","reference":"BB15A (ČSN 75 7717)","norm_bases":["BB15A","ČSN 75 7717"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, surowe i uzdatnione, rozmyte osady denne Oznaczanie sinic planktonowych metodą mikroskopową Vody povrchové, surové a upravené, rozplavené sedimenty Stanovení planktonních sinic mikroskopicky BB15A (ČSN 75 7717) Wody powierzchniowe, surowe i uzdatnione, rozmyte osady denne Oznaczanie sinic planktonowych metoda mikroskopowa Vody povrchove, surove a upravene, rozplavene sedimenty Stanoveni planktonnich sinic mikroskopicky BB15A (CSN 75 7717)","search_en":"Surface, raw and treated water, suspended sediments Determination of planktonic cyanobacteria by microscopy BB15A (ČSN 75 7717)","search_zh":"地表水、原水和处理水、悬浮沉积物 显微镜法测定浮游蓝藻 BB15A (ČSN 75 7717)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":92,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"54febbf2560eb39e8f1c7a44","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"94","test_object":"Wody powierzchniowe, podziemne, przeznaczone do spożycia, ścieki i wody technologiczne","test_object_en":"Surface, ground, drinking, waste and process water","test_object_zh":"地表水、地下水、饮用水、废水和工艺用水","test_object_cs":"Vody povrchové, podzemní, pitné, odpadní a technologické","methodology":"Obrazowanie obiektów mikroskopowych metodą skaningowej mikroskopii elektronowej i wykorzystanie dużego powiększenia przy oznaczaniu wybranych grup organizmów w próbkach fitoplanktonu i fitobentosu","methodology_en":"Imaging of microscopic objects by scanning electron microscopy and use of high magnification to identify selected groups of organisms in phytoplankton and phytobenthos samples","methodology_zh":"扫描电子显微镜成像及高倍放大鉴定浮游植物和底栖植物样品中的选定生物类群","methodology_cs":"Zobrazení mikroskopických objektů pomocí skenování elektronové mikroskopie a využití velkého zvětšení při určování vybraných skupin organismů ve vzorcích fytoplanktonu a fytobentosu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Obrazowanie obiektów mikroskopowych metodą skaningowej mikroskopii elektronowej i wykorzystanie dużego powiększenia przy oznaczaniu wybranych grup organizmów w próbkach fitoplanktonu i fitobentosu","reference":"BB16A (Uživatelská příručka Phenom)","norm_bases":["BB16A","Uživatelská příručka Phenom"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, podziemne, przeznaczone do spożycia, ścieki i wody technologiczne Obrazowanie obiektów mikroskopowych metodą skaningowej mikroskopii elektronowej i wykorzystanie dużego powiększenia przy oznaczaniu wybranych grup organizmów w próbkach fitoplanktonu i fitobentosu Vody povrchové, podzemní, pitné, odpadní a technologické Zobrazení mikroskopických objektů pomocí skenování elektronové mikroskopie a využití velkého zvětšení při určování vybraných skupin organismů ve vzorcích fytoplanktonu a fytobentosu BB16A (Uživatelská příručka Phenom) Wody powierzchniowe, podziemne, przeznaczone do spozycia, scieki i wody technologiczne Obrazowanie obiektow mikroskopowych metoda skaningowej mikroskopii elektronowej i wykorzystanie duzego powiekszenia przy oznaczaniu wybranych grup organizmow w probkach fitoplanktonu i fitobentosu Vody povrchove, podzemni, pitne, odpadni a technologicke Zobrazeni mikroskopickych objektu pomoci skenovani elektronove mikroskopie a vyuziti velkeho zvetseni pri urcovani vybranych skupin organismu ve vzorcich fytoplanktonu a fytobentosu BB16A (Uzivatelska prirucka Phenom)","search_en":"Surface, ground, drinking, waste and process water Imaging of microscopic objects by scanning electron microscopy and use of high magnification to identify selected groups of organisms in phytoplankton and phytobenthos samples BB16A (Uživatelská příručka Phenom)","search_zh":"地表水、地下水、饮用水、废水和工艺用水 扫描电子显微镜成像及高倍放大鉴定浮游植物和底栖植物样品中的选定生物类群 BB16A (Uživatelská příručka Phenom)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":93,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25335a723e9c7920d0a19588","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"95","test_object":"Osady denne, grunty, odpady stałe","test_object_en":"Sediments, earths, solid waste","test_object_zh":"沉积物、土、固体废物","test_object_cs":"Sedimenty, zeminy, pevné odpady","methodology":"Obrazowanie obiektów mikroskopowych metodą skaningowej mikroskopii elektronowej i wykorzystanie dużego powiększenia przy oznaczaniu wybranych grup organizmów","methodology_en":"Imaging of microscopic objects by scanning electron microscopy and use of high magnification to identify selected groups of organisms","methodology_zh":"扫描电子显微镜成像及高倍放大鉴定选定生物类群","methodology_cs":"Zobrazení mikroskopických objektů pomocí skenování elektronové mikroskopie a využití velkého zvětšení při určování vybraných skupin organismů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Obrazowanie obiektów mikroskopowych metodą skaningowej mikroskopii elektronowej i wykorzystanie dużego powiększenia przy oznaczaniu wybranych grup organizmów","reference":"BB16B (Uživatelská příručka Phenom)","norm_bases":["BB16B","Uživatelská příručka Phenom"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady denne, grunty, odpady stałe Obrazowanie obiektów mikroskopowych metodą skaningowej mikroskopii elektronowej i wykorzystanie dużego powiększenia przy oznaczaniu wybranych grup organizmów Sedimenty, zeminy, pevné odpady Zobrazení mikroskopických objektů pomocí skenování elektronové mikroskopie a využití velkého zvětšení při určování vybraných skupin organismů BB16B (Uživatelská příručka Phenom) Osady denne, grunty, odpady stale Obrazowanie obiektow mikroskopowych metoda skaningowej mikroskopii elektronowej i wykorzystanie duzego powiekszenia przy oznaczaniu wybranych grup organizmow Sedimenty, zeminy, pevne odpady Zobrazeni mikroskopickych objektu pomoci skenovani elektronove mikroskopie a vyuziti velkeho zvetseni pri urcovani vybranych skupin organismu BB16B (Uzivatelska prirucka Phenom)","search_en":"Sediments, earths, solid waste Imaging of microscopic objects by scanning electron microscopy and use of high magnification to identify selected groups of organisms BB16B (Uživatelská příručka Phenom)","search_zh":"沉积物、土、固体废物 扫描电子显微镜成像及高倍放大鉴定选定生物类群 BB16B (Uživatelská příručka Phenom)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":94,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5cd3e4da1d8df6ed493fb8b3","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"96","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi, chemikalia","test_object_en":"Drinking, surface, ground, waste and process water, leachates, chemicals","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液、化学品","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy, chemikálie","methodology":"Testy toksyczności ostrej – hamowanie ruchliwości Daphnia magna","methodology_en":"Acute toxicity tests – inhibition of the mobility of Daphnia magna","methodology_zh":"急性毒性试验–大型溞活动抑制","methodology_cs":"Testy akutní toxicity – inhibice pohyblivosti Daphnia magna","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Testy toksyczności ostrej – hamowanie ruchliwości Daphnia magna","reference":"BE02A (ČSN EN ISO 6341)","norm_bases":["BE02A","ČSN EN ISO 6341"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi, chemikalia Testy toksyczności ostrej – hamowanie ruchliwości Daphnia magna Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy, chemikálie Testy akutní toxicity – inhibice pohyblivosti Daphnia magna BE02A (ČSN EN ISO 6341) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi, chemikalia Testy toksycznosci ostrej – hamowanie ruchliwosci Daphnia magna Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy, chemikalie Testy akutni toxicity – inhibice pohyblivosti Daphnia magna BE02A (CSN EN ISO 6341)","search_en":"Drinking, surface, ground, waste and process water, leachates, chemicals Acute toxicity tests – inhibition of the mobility of Daphnia magna BE02A (ČSN EN ISO 6341)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液、化学品 急性毒性试验–大型溞活动抑制 BE02A (ČSN EN ISO 6341)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":95,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"149b20b0e3314f3f52da9920","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"97","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi, chemikalia","test_object_en":"Drinking, surface, ground, waste and process water, leachates, chemicals","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液、化学品","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy, chemikálie","methodology":"Testy toksyczności ostrej – hamowanie wzrostu korzenia Sinapis alba","methodology_en":"Acute toxicity tests – inhibition of Sinapis alba root growth","methodology_zh":"急性毒性试验–白芥根生长抑制","methodology_cs":"Testy akutní toxicity – inhibice růstu kořene Sinapis alba","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Testy toksyczności ostrej – hamowanie wzrostu korzenia Sinapis alba","reference":"BE03A (Metodický pokyn 8, Věstník MŽP ČR, roč. XVII, č.4/2007)","norm_bases":["BE03A","Metodický pokyn 8, Věstník MŽP ČR, roč. XVII, č.4/2007"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi, chemikalia Testy toksyczności ostrej – hamowanie wzrostu korzenia Sinapis alba Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy, chemikálie Testy akutní toxicity – inhibice růstu kořene Sinapis alba BE03A (Metodický pokyn 8, Věstník MŽP ČR, roč. XVII, č.4/2007) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi, chemikalia Testy toksycznosci ostrej – hamowanie wzrostu korzenia Sinapis alba Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy, chemikalie Testy akutni toxicity – inhibice rustu korene Sinapis alba BE03A (Metodicky pokyn 8, Vestnik MZP CR, roc. XVII, c.4/2007)","search_en":"Drinking, surface, ground, waste and process water, leachates, chemicals Acute toxicity tests – inhibition of Sinapis alba root growth BE03A (Metodický pokyn 8, Věstník MŽP ČR, roč. XVII, č.4/2007)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液、化学品 急性毒性试验–白芥根生长抑制 BE03A (Metodický pokyn 8, Věstník MŽP ČR, roč. XVII, č.4/2007)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":96,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5ab53a3db28d87a9403b16c0","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"98","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi, chemikalia","test_object_en":"Drinking, surface, ground, waste and process water, leachates, chemicals","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液、化学品","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy, chemikálie","methodology":"Testy toksyczności ostrej – hamowanie wzrostu glonów słodkowodnych Desmodesmus subspicatus","methodology_en":"Acute toxicity tests – freshwater algal growth inhibition with Desmodesmus subspicatus","methodology_zh":"急性毒性试验–淡水藻类（Desmodesmus subspicatus）生长抑制","methodology_cs":"Testy akutní toxicity – inhibice růstu sladkovodních řas Desmodesmus subspicatus","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Testy toksyczności ostrej – hamowanie wzrostu glonów słodkowodnych Desmodesmus subspicatus","reference":"BE04A (ČSN EN ISO 8692)","norm_bases":["BE04A","ČSN EN ISO 8692"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi, chemikalia Testy toksyczności ostrej – hamowanie wzrostu glonów słodkowodnych Desmodesmus subspicatus Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy, chemikálie Testy akutní toxicity – inhibice růstu sladkovodních řas Desmodesmus subspicatus BE04A (ČSN EN ISO 8692) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi, chemikalia Testy toksycznosci ostrej – hamowanie wzrostu glonow slodkowodnych Desmodesmus subspicatus Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy, chemikalie Testy akutni toxicity – inhibice rustu sladkovodnich ras Desmodesmus subspicatus BE04A (CSN EN ISO 8692)","search_en":"Drinking, surface, ground, waste and process water, leachates, chemicals Acute toxicity tests – freshwater algal growth inhibition with Desmodesmus subspicatus BE04A (ČSN EN ISO 8692)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液、化学品 急性毒性试验–淡水藻类（Desmodesmus subspicatus）生长抑制 BE04A (ČSN EN ISO 8692)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":97,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"85aec3ecf844ddd4c9b9efb8","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"99","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi, chemikalia","test_object_en":"Drinking, surface, ground, waste and process water, leachates, chemicals","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液、化学品","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy, chemikálie","methodology":"Testy toksyczności ostrej – bakteryjny test bioluminescencyjny","methodology_en":"Acute toxicity tests – bacterial bioluminescence test","methodology_zh":"急性毒性试验–细菌生物发光试验","methodology_cs":"Testy akutní toxicity – bakteriální bioluminiscenční test","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Testy toksyczności ostrej – bakteryjny test bioluminescencyjny","reference":"BE06A (ČSN EN ISO 11348-2)","norm_bases":["BE06A","ČSN EN ISO 11348-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne, wyciągi, chemikalia Testy toksyczności ostrej – bakteryjny test bioluminescencyjny Vody pitné, povrchové, podzemní, odpadní a technologické, výluhy, chemikálie Testy akutní toxicity – bakteriální bioluminiscenční test BE06A (ČSN EN ISO 11348-2) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne, wyciagi, chemikalia Testy toksycznosci ostrej – bakteryjny test bioluminescencyjny Vody pitne, povrchove, podzemni, odpadni a technologicke, vyluhy, chemikalie Testy akutni toxicity – bakterialni bioluminiscencni test BE06A (CSN EN ISO 11348-2)","search_en":"Drinking, surface, ground, waste and process water, leachates, chemicals Acute toxicity tests – bacterial bioluminescence test BE06A (ČSN EN ISO 11348-2)","search_zh":"饮用水、地表水、地下水、废水和工艺用水、浸出液、化学品 急性毒性试验–细菌生物发光试验 BE06A (ČSN EN ISO 11348-2)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":98,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f2ae76a7f4ef334e0d85ab7b","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"100","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne","test_object_en":"Drinking, surface, ground, waste and process water","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické","methodology":"Oznaczanie bakterii grupy coli i termotolerancyjnych bakterii grupy coli metodą filtracji membranowej","methodology_en":"Enumeration of coliform and thermotolerant coliform bacteria by membrane filtration","methodology_zh":"膜过滤法测定大肠菌群和耐热大肠菌群","methodology_cs":"Stanovení koliformních a termotolerantních koliformních bakterií metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii grupy coli i termotolerancyjnych bakterii grupy coli metodą filtracji membranowej","reference":"BM01A (ČSN 75 7835; ČSN 75 7837)","norm_bases":["BM01A","ČSN 75 7835","ČSN 75 7837"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne Oznaczanie bakterii grupy coli i termotolerancyjnych bakterii grupy coli metodą filtracji membranowej Vody pitné, povrchové, podzemní, odpadní a technologické Stanovení koliformních a termotolerantních koliformních bakterií metodou membránové filtrace BM01A (ČSN 75 7835; ČSN 75 7837) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne Oznaczanie bakterii grupy coli i termotolerancyjnych bakterii grupy coli metoda filtracji membranowej Vody pitne, povrchove, podzemni, odpadni a technologicke Stanoveni koliformnich a termotolerantnich koliformnich bakterii metodou membranove filtrace BM01A (CSN 75 7835; CSN 75 7837)","search_en":"Drinking, surface, ground, waste and process water Enumeration of coliform and thermotolerant coliform bacteria by membrane filtration BM01A (ČSN 75 7835; ČSN 75 7837)","search_zh":"饮用水、地表水、地下水、废水和工艺用水 膜过滤法测定大肠菌群和耐热大肠菌群 BM01A (ČSN 75 7835; ČSN 75 7837)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":99,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2c408a76fc568f955f343667","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"101","test_object":"Wody powierzchniowe, podziemne i ścieki","test_object_en":"Surface, ground and waste water","test_object_zh":"地表水、地下水和废水","test_object_cs":"Vody povrchové, podzemní a odpadní","methodology":"Oznaczanie bakterii grupy coli i termotolerancyjnych bakterii grupy coli metodą posiewu bezpośredniego","methodology_en":"Enumeration of coliform and thermotolerant coliform bacteria by direct plating","methodology_zh":"直接涂布法测定大肠菌群和耐热大肠菌群","methodology_cs":"Stanovení koliformních a termotolerantních koliformních bakterií metodou přímého výsevu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii grupy coli i termotolerancyjnych bakterii grupy coli metodą posiewu bezpośredniego","reference":"BM02A (ČSN 75 7835; ČSN 75 7837)","norm_bases":["BM02A","ČSN 75 7835","ČSN 75 7837"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, podziemne i ścieki Oznaczanie bakterii grupy coli i termotolerancyjnych bakterii grupy coli metodą posiewu bezpośredniego Vody povrchové, podzemní a odpadní Stanovení koliformních a termotolerantních koliformních bakterií metodou přímého výsevu BM02A (ČSN 75 7835; ČSN 75 7837) Wody powierzchniowe, podziemne i scieki Oznaczanie bakterii grupy coli i termotolerancyjnych bakterii grupy coli metoda posiewu bezposredniego Vody povrchove, podzemni a odpadni Stanoveni koliformnich a termotolerantnich koliformnich bakterii metodou primeho vysevu BM02A (CSN 75 7835; CSN 75 7837)","search_en":"Surface, ground and waste water Enumeration of coliform and thermotolerant coliform bacteria by direct plating BM02A (ČSN 75 7835; ČSN 75 7837)","search_zh":"地表水、地下水和废水 直接涂布法测定大肠菌群和耐热大肠菌群 BM02A (ČSN 75 7835; ČSN 75 7837)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":100,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ef67b98a14a1f8538591f5a6","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"102","test_object":"Osady, osady denne i bioodpady","test_object_en":"Sludge, sediments and biowaste","test_object_zh":"污泥、沉积物和生物废物","test_object_cs":"Kaly, sedimenty a bioodpady","methodology":"Oznaczanie termotolerancyjnych bakterii grupy coli metodą filtracji membranowej","methodology_en":"Enumeration of thermotolerant coliform bacteria by membrane filtration","methodology_zh":"膜过滤法测定耐热大肠菌群","methodology_cs":"Stanovení termotolerantních koliformních bakterií metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie termotolerancyjnych bakterii grupy coli metodą filtracji membranowej","reference":"BM02B (ČSN 75 7835; Matějů, L.: Metodický návod pro stanovení indikátorových organismů, AHEM 1/2008)","norm_bases":["BM02B","ČSN 75 7835","Matějů, L.: Metodický návod pro stanovení indikátorových organismů, AHEM 1/2008"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady, osady denne i bioodpady Oznaczanie termotolerancyjnych bakterii grupy coli metodą filtracji membranowej Kaly, sedimenty a bioodpady Stanovení termotolerantních koliformních bakterií metodou membránové filtrace BM02B (ČSN 75 7835; Matějů, L.: Metodický návod pro stanovení indikátorových organismů, AHEM 1/2008) Osady, osady denne i bioodpady Oznaczanie termotolerancyjnych bakterii grupy coli metoda filtracji membranowej Kaly, sedimenty a bioodpady Stanoveni termotolerantnich koliformnich bakterii metodou membranove filtrace BM02B (CSN 75 7835; Mateju, L.: Metodicky navod pro stanoveni indikatorovych organismu, AHEM 1/2008)","search_en":"Sludge, sediments and biowaste Enumeration of thermotolerant coliform bacteria by membrane filtration BM02B (ČSN 75 7835; Matějů, L.: Metodický návod pro stanovení indikátorových organismů, AHEM 1/2008)","search_zh":"污泥、沉积物和生物废物 膜过滤法测定耐热大肠菌群 BM02B (ČSN 75 7835; Matějů, L.: Metodický návod pro stanovení indikátorových organismů, AHEM 1/2008)","categories":["microbiology","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":101,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6fcbb8d5a296e3d039df7c08","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"103","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne","test_object_en":"Drinking, surface, ground, waste and process water","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické","methodology":"Oznaczanie enterokoków jelitowych metodą filtracji membranowej","methodology_en":"Enumeration of intestinal enterococci by membrane filtration","methodology_zh":"膜过滤法测定肠球菌","methodology_cs":"Stanovení intestinálních enterokoků metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie enterokoków jelitowych metodą filtracji membranowej","reference":"BM05A (ČSN EN ISO 7899-2)","norm_bases":["BM05A","ČSN EN ISO 7899-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne Oznaczanie enterokoków jelitowych metodą filtracji membranowej Vody pitné, povrchové, podzemní, odpadní a technologické Stanovení intestinálních enterokoků metodou membránové filtrace BM05A (ČSN EN ISO 7899-2) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne Oznaczanie enterokokow jelitowych metoda filtracji membranowej Vody pitne, povrchove, podzemni, odpadni a technologicke Stanoveni intestinalnich enterokoku metodou membranove filtrace BM05A (CSN EN ISO 7899-2)","search_en":"Drinking, surface, ground, waste and process water Enumeration of intestinal enterococci by membrane filtration BM05A (ČSN EN ISO 7899-2)","search_zh":"饮用水、地表水、地下水、废水和工艺用水 膜过滤法测定肠球菌 BM05A (ČSN EN ISO 7899-2)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":102,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6e45b90710a282d44e435b12","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"104","test_object":"Osady, osady denne i bioodpady","test_object_en":"Sludge, sediments and biowaste","test_object_zh":"污泥、沉积物和生物废物","test_object_cs":"Kaly, sedimenty a bioodpady","methodology":"Oznaczanie enterokoków jelitowych metodą filtracji membranowej","methodology_en":"Enumeration of intestinal enterococci by membrane filtration","methodology_zh":"膜过滤法测定肠球菌","methodology_cs":"Stanovení intestinálních enterokoků metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie enterokoków jelitowych metodą filtracji membranowej","reference":"BM05B (ČSN EN ISO 7899-2; Matějů, L.: Metodický návod pro stanovení indikátorových organismů, AHEM 1/2008)","norm_bases":["BM05B","ČSN EN ISO 7899-2","Matějů, L.: Metodický návod pro stanovení indikátorových organismů, AHEM 1/2008"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady, osady denne i bioodpady Oznaczanie enterokoków jelitowych metodą filtracji membranowej Kaly, sedimenty a bioodpady Stanovení intestinálních enterokoků metodou membránové filtrace BM05B (ČSN EN ISO 7899-2; Matějů, L.: Metodický návod pro stanovení indikátorových organismů, AHEM 1/2008) Osady, osady denne i bioodpady Oznaczanie enterokokow jelitowych metoda filtracji membranowej Kaly, sedimenty a bioodpady Stanoveni intestinalnich enterokoku metodou membranove filtrace BM05B (CSN EN ISO 7899-2; Mateju, L.: Metodicky navod pro stanoveni indikatorovych organismu, AHEM 1/2008)","search_en":"Sludge, sediments and biowaste Enumeration of intestinal enterococci by membrane filtration BM05B (ČSN EN ISO 7899-2; Matějů, L.: Metodický návod pro stanovení indikátorových organismů, AHEM 1/2008)","search_zh":"污泥、沉积物和生物废物 膜过滤法测定肠球菌 BM05B (ČSN EN ISO 7899-2; Matějů, L.: Metodický návod pro stanovení indikátorových organismů, AHEM 1/2008)","categories":["microbiology","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":103,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7cb8b16b22f90067842c9d66","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"105","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne","test_object_en":"Drinking, surface, ground, waste and process water","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické","methodology":"Oznaczanie Escherichia coli, identyfikacja i oznaczanie ilościowe z użyciem substratu fluorogenicznego metodą filtracji membranowej","methodology_en":"Determination of Escherichia coli, identification and enumeration using a fluorogenic substrate by membrane filtration","methodology_zh":"膜过滤-荧光底物法鉴定和定量测定大肠埃希氏菌","methodology_cs":"Stanovení Escherichia coli, identifikace a kvantitativní stanovení pomocí fluorogenního substrátu metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Escherichia coli, identyfikacja i oznaczanie ilościowe z użyciem substratu fluorogenicznego metodą filtracji membranowej","reference":"BM09A (ČSN 75 7835)","norm_bases":["BM09A","ČSN 75 7835"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne Oznaczanie Escherichia coli, identyfikacja i oznaczanie ilościowe z użyciem substratu fluorogenicznego metodą filtracji membranowej Vody pitné, povrchové, podzemní, odpadní a technologické Stanovení Escherichia coli, identifikace a kvantitativní stanovení pomocí fluorogenního substrátu metodou membránové filtrace BM09A (ČSN 75 7835) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne Oznaczanie Escherichia coli, identyfikacja i oznaczanie ilosciowe z uzyciem substratu fluorogenicznego metoda filtracji membranowej Vody pitne, povrchove, podzemni, odpadni a technologicke Stanoveni Escherichia coli, identifikace a kvantitativni stanoveni pomoci fluorogenniho substratu metodou membranove filtrace BM09A (CSN 75 7835)","search_en":"Drinking, surface, ground, waste and process water Determination of Escherichia coli, identification and enumeration using a fluorogenic substrate by membrane filtration BM09A (ČSN 75 7835)","search_zh":"饮用水、地表水、地下水、废水和工艺用水 膜过滤-荧光底物法鉴定和定量测定大肠埃希氏菌 BM09A (ČSN 75 7835)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":104,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ee20e6c33c5731e439308a16","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"106","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne","test_object_en":"Drinking, surface, ground, waste and process water","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické","methodology":"Wykrywanie obecności bakterii z rodzaju Salmonella metodą hodowlaną","methodology_en":"Detection of Salmonella bacteria by culture","methodology_zh":"培养法检测沙门氏菌属细菌","methodology_cs":"Průkaz přítomnosti bakterií rodu Salmonella kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie obecności bakterii z rodzaju Salmonella metodą hodowlaną","reference":"BM10A (ČSN ISO 19250)","norm_bases":["BM10A","ČSN ISO 19250"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne Wykrywanie obecności bakterii z rodzaju Salmonella metodą hodowlaną Vody pitné, povrchové, podzemní, odpadní a technologické Průkaz přítomnosti bakterií rodu Salmonella kultivačně BM10A (ČSN ISO 19250) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne Wykrywanie obecnosci bakterii z rodzaju Salmonella metoda hodowlana Vody pitne, povrchove, podzemni, odpadni a technologicke Prukaz pritomnosti bakterii rodu Salmonella kultivacne BM10A (CSN ISO 19250)","search_en":"Drinking, surface, ground, waste and process water Detection of Salmonella bacteria by culture BM10A (ČSN ISO 19250)","search_zh":"饮用水、地表水、地下水、废水和工艺用水 培养法检测沙门氏菌属细菌 BM10A (ČSN ISO 19250)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":105,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b2436313a77205134e4612b5","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"107","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne","test_object_en":"Drinking, surface, ground, waste and process water","test_object_zh":"饮用水、地表水、地下水、废水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní a technologické","methodology":"Oznaczanie przetrwalników beztlenowców redukujących siarczyny (klostridiów) metodą filtracji membranowej","methodology_en":"Enumeration of spores of sulphite-reducing anaerobes (clostridia) by membrane filtration","methodology_zh":"膜过滤法测定亚硫酸盐还原厌氧菌（梭菌）孢子","methodology_cs":"Stanovení spor siřičitany redukujících anaerobů (klostridií) metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przetrwalników beztlenowców redukujących siarczyny (klostridiów) metodą filtracji membranowej","reference":"BM11A (ČSN EN 26461-2)","norm_bases":["BM11A","ČSN EN 26461-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne, ścieki i wody technologiczne Oznaczanie przetrwalników beztlenowców redukujących siarczyny (klostridiów) metodą filtracji membranowej Vody pitné, povrchové, podzemní, odpadní a technologické Stanovení spor siřičitany redukujících anaerobů (klostridií) metodou membránové filtrace BM11A (ČSN EN 26461-2) Wody przeznaczone do spozycia, powierzchniowe, podziemne, scieki i wody technologiczne Oznaczanie przetrwalnikow beztlenowcow redukujacych siarczyny (klostridiow) metoda filtracji membranowej Vody pitne, povrchove, podzemni, odpadni a technologicke Stanoveni spor siricitany redukujicich anaerobu (klostridii) metodou membranove filtrace BM11A (CSN EN 26461-2)","search_en":"Drinking, surface, ground, waste and process water Enumeration of spores of sulphite-reducing anaerobes (clostridia) by membrane filtration BM11A (ČSN EN 26461-2)","search_zh":"饮用水、地表水、地下水、废水和工艺用水 膜过滤法测定亚硫酸盐还原厌氧菌（梭菌）孢子 BM11A (ČSN EN 26461-2)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":106,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d76ddd28fea2142ddff4a4a7","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"108","test_object":"Wody przeznaczone do spożycia, powierzchniowe i podziemne","test_object_en":"Drinking, surface and ground water","test_object_zh":"饮用水、地表水和地下水","test_object_cs":"Vody pitné, povrchové a podzemní","methodology":"Oznaczanie Clostridium perfringens metodą filtracji membranowej","methodology_en":"Enumeration of Clostridium perfringens by membrane filtration","methodology_zh":"膜过滤法测定产气荚膜梭菌","methodology_cs":"Stanovení Clostridium perfringens metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Clostridium perfringens metodą filtracji membranowej","reference":"BM12A (Vyhláška č. 252/2004 Sb., Příloha č. 6)","norm_bases":["BM12A","Vyhláška č. 252/2004 Sb., Příloha č. 6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe i podziemne Oznaczanie Clostridium perfringens metodą filtracji membranowej Vody pitné, povrchové a podzemní Stanovení Clostridium perfringens metodou membránové filtrace BM12A (Vyhláška č. 252/2004 Sb., Příloha č. 6) Wody przeznaczone do spozycia, powierzchniowe i podziemne Oznaczanie Clostridium perfringens metoda filtracji membranowej Vody pitne, povrchove a podzemni Stanoveni Clostridium perfringens metodou membranove filtrace BM12A (Vyhlaska c. 252/2004 Sb., Priloha c. 6)","search_en":"Drinking, surface and ground water Enumeration of Clostridium perfringens by membrane filtration BM12A (Vyhláška č. 252/2004 Sb., Příloha č. 6)","search_zh":"饮用水、地表水和地下水 膜过滤法测定产气荚膜梭菌 BM12A (Vyhláška č. 252/2004 Sb., Příloha č. 6)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":107,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"016349f1a83195fcba2c9df6","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"109","test_object":"Wody przeznaczone do spożycia, butelkowane, technologiczne i basenowe","test_object_en":"Drinking, bottled, process and swimming pool water","test_object_zh":"饮用水、瓶装水、工艺用水和泳池水","test_object_cs":"Vody pitné, balené, technologické a bazénové","methodology":"Oznaczanie Pseudomonas aeruginosa metodą filtracji membranowej","methodology_en":"Enumeration of Pseudomonas aeruginosa by membrane filtration","methodology_zh":"膜过滤法测定铜绿假单胞菌","methodology_cs":"Stanovení Pseudomonas aeruginosa metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Pseudomonas aeruginosa metodą filtracji membranowej","reference":"BM13A (ČSN EN ISO 16266)","norm_bases":["BM13A","ČSN EN ISO 16266"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, butelkowane, technologiczne i basenowe Oznaczanie Pseudomonas aeruginosa metodą filtracji membranowej Vody pitné, balené, technologické a bazénové Stanovení Pseudomonas aeruginosa metodou membránové filtrace BM13A (ČSN EN ISO 16266) Wody przeznaczone do spozycia, butelkowane, technologiczne i basenowe Oznaczanie Pseudomonas aeruginosa metoda filtracji membranowej Vody pitne, balene, technologicke a bazenove Stanoveni Pseudomonas aeruginosa metodou membranove filtrace BM13A (CSN EN ISO 16266)","search_en":"Drinking, bottled, process and swimming pool water Enumeration of Pseudomonas aeruginosa by membrane filtration BM13A (ČSN EN ISO 16266)","search_zh":"饮用水、瓶装水、工艺用水和泳池水 膜过滤法测定铜绿假单胞菌 BM13A (ČSN EN ISO 16266)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":108,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fbf14999b951c6df80435d1e","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"110","test_object":"Wody przeznaczone do spożycia, podziemne i technologiczne","test_object_en":"Drinking, ground and process water","test_object_zh":"饮用水、地下水和工艺用水","test_object_cs":"Vody pitné, podzemní a technologické","methodology":"Oznaczanie Escherichia coli i bakterii grupy coli metodą filtracji membranowej","methodology_en":"Enumeration of Escherichia coli and coliform bacteria by membrane filtration","methodology_zh":"膜过滤法测定大肠埃希氏菌和大肠菌群","methodology_cs":"Stanovení Escherichia coli a koliformních bakterií metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Escherichia coli i bakterii grupy coli metodą filtracji membranowej","reference":"BM14A (ČSN EN ISO 9308-1)","norm_bases":["BM14A","ČSN EN ISO 9308-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, podziemne i technologiczne Oznaczanie Escherichia coli i bakterii grupy coli metodą filtracji membranowej Vody pitné, podzemní a technologické Stanovení Escherichia coli a koliformních bakterií metodou membránové filtrace BM14A (ČSN EN ISO 9308-1) Wody przeznaczone do spozycia, podziemne i technologiczne Oznaczanie Escherichia coli i bakterii grupy coli metoda filtracji membranowej Vody pitne, podzemni a technologicke Stanoveni Escherichia coli a koliformnich bakterii metodou membranove filtrace BM14A (CSN EN ISO 9308-1)","search_en":"Drinking, ground and process water Enumeration of Escherichia coli and coliform bacteria by membrane filtration BM14A (ČSN EN ISO 9308-1)","search_zh":"饮用水、地下水和工艺用水 膜过滤法测定大肠埃希氏菌和大肠菌群 BM14A (ČSN EN ISO 9308-1)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":109,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e6d800f3d1a6ec62f67a9aa0","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"111","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne i technologiczne","test_object_en":"Drinking, surface, ground and process water","test_object_zh":"饮用水、地表水、地下水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní a technologické","methodology":"Oznaczanie mikroorganizmów hodowalnych w 22 °C i 36 °C metodą posiewu bezpośredniego do podłoża agarowego","methodology_en":"Enumeration of culturable micro-organisms at 22 °C and 36 °C by direct inoculation into agar medium","methodology_zh":"直接接种琼脂培养基法测定22 °C和36 °C可培养微生物","methodology_cs":"Stanovení kultivovatelných mikroorganismů při 22 °C a 36 °C metodou přímého výsevu do agarového média","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mikroorganizmów hodowalnych w 22 °C i 36 °C metodą posiewu bezpośredniego do podłoża agarowego","reference":"BM15A (ČSN EN ISO 6222)","norm_bases":["BM15A","ČSN EN ISO 6222"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne i technologiczne Oznaczanie mikroorganizmów hodowalnych w 22 °C i 36 °C metodą posiewu bezpośredniego do podłoża agarowego Vody pitné, povrchové, podzemní a technologické Stanovení kultivovatelných mikroorganismů při 22 °C a 36 °C metodou přímého výsevu do agarového média BM15A (ČSN EN ISO 6222) Wody przeznaczone do spozycia, powierzchniowe, podziemne i technologiczne Oznaczanie mikroorganizmow hodowalnych w 22 °C i 36 °C metoda posiewu bezposredniego do podloza agarowego Vody pitne, povrchove, podzemni a technologicke Stanoveni kultivovatelnych mikroorganismu pri 22 °C a 36 °C metodou primeho vysevu do agaroveho media BM15A (CSN EN ISO 6222)","search_en":"Drinking, surface, ground and process water Enumeration of culturable micro-organisms at 22 °C and 36 °C by direct inoculation into agar medium BM15A (ČSN EN ISO 6222)","search_zh":"饮用水、地表水、地下水和工艺用水 直接接种琼脂培养基法测定22 °C和36 °C可培养微生物 BM15A (ČSN EN ISO 6222)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":110,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f98f62f0f920ed7465f70eac","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"112","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne i technologiczne","test_object_en":"Drinking, surface, ground and process water","test_object_zh":"饮用水、地表水、地下水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní a technologické","methodology":"Oznaczanie bakterii grupy coli i Escherichia coli metodą Colilert-18 Quanti-Tray","methodology_en":"Enumeration of coliform bacteria and Escherichia coli by the Colilert-18 Quanti-Tray method","methodology_zh":"Colilert-18 Quanti-Tray法测定大肠菌群和大肠埃希氏菌","methodology_cs":"Stanovení koliformních bakterií a Escherichia coli metodou Colilert-18 Quanti-Tray","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii grupy coli i Escherichia coli metodą Colilert-18 Quanti-Tray","reference":"BM16A (ČSN EN ISO 9308-2)","norm_bases":["BM16A","ČSN EN ISO 9308-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne i technologiczne Oznaczanie bakterii grupy coli i Escherichia coli metodą Colilert-18 Quanti-Tray Vody pitné, povrchové, podzemní a technologické Stanovení koliformních bakterií a Escherichia coli metodou Colilert-18 Quanti-Tray BM16A (ČSN EN ISO 9308-2) Wody przeznaczone do spozycia, powierzchniowe, podziemne i technologiczne Oznaczanie bakterii grupy coli i Escherichia coli metoda Colilert-18 Quanti-Tray Vody pitne, povrchove, podzemni a technologicke Stanoveni koliformnich bakterii a Escherichia coli metodou Colilert-18 Quanti-Tray BM16A (CSN EN ISO 9308-2)","search_en":"Drinking, surface, ground and process water Enumeration of coliform bacteria and Escherichia coli by the Colilert-18 Quanti-Tray method BM16A (ČSN EN ISO 9308-2)","search_zh":"饮用水、地表水、地下水和工艺用水 Colilert-18 Quanti-Tray法测定大肠菌群和大肠埃希氏菌 BM16A (ČSN EN ISO 9308-2)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":111,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"67f2859287fb21b46c7adb3c","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"113","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne i technologiczne","test_object_en":"Drinking, surface, ground and process water","test_object_zh":"饮用水、地表水、地下水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní a technologické","methodology":"Oznaczanie enterokoków jelitowych metodą Enterolert-E Quanti-Tray","methodology_en":"Enumeration of intestinal enterococci by the Enterolert-E Quanti-Tray method","methodology_zh":"Enterolert-E Quanti-Tray法测定肠球菌","methodology_cs":"Stanovení intestinálních enterokoků metodou Enterolert–E Quanti-Tray","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie enterokoków jelitowych metodą Enterolert-E Quanti-Tray","reference":"BM19A (Návod, IDEXX, Quanti-Tray/2000)","norm_bases":["BM19A","Návod, IDEXX, Quanti-Tray/2000"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne i technologiczne Oznaczanie enterokoków jelitowych metodą Enterolert-E Quanti-Tray Vody pitné, povrchové, podzemní a technologické Stanovení intestinálních enterokoků metodou Enterolert–E Quanti-Tray BM19A (Návod, IDEXX, Quanti-Tray/2000) Wody przeznaczone do spozycia, powierzchniowe, podziemne i technologiczne Oznaczanie enterokokow jelitowych metoda Enterolert-E Quanti-Tray Vody pitne, povrchove, podzemni a technologicke Stanoveni intestinalnich enterokoku metodou Enterolert–E Quanti-Tray BM19A (Navod, IDEXX, Quanti-Tray/2000)","search_en":"Drinking, surface, ground and process water Enumeration of intestinal enterococci by the Enterolert-E Quanti-Tray method BM19A (Návod, IDEXX, Quanti-Tray/2000)","search_zh":"饮用水、地表水、地下水和工艺用水 Enterolert-E Quanti-Tray法测定肠球菌 BM19A (Návod, IDEXX, Quanti-Tray/2000)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":112,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ac0a4c6f05ff0a04cdd8521e","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"114","test_object":"Wody przeznaczone do spożycia, powierzchniowe, podziemne i technologiczne","test_object_en":"Drinking, surface, ground and process water","test_object_zh":"饮用水、地表水、地下水和工艺用水","test_object_cs":"Vody pitné, povrchové, podzemní a technologické","methodology":"Metoda oznaczania liczby gronkowców koagulazododatnich metodą filtracji membranowej","methodology_en":"Method for the enumeration of coagulase-positive staphylococci by membrane filtration","methodology_zh":"膜过滤法测定凝固酶阳性葡萄球菌数","methodology_cs":"Metoda stanovení počtu koagulázopozitivních stafylokoků metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Metoda oznaczania liczby gronkowców koagulazododatnich metodą filtracji membranowej","reference":"BM20A (ČSN EN ISO 6888-1)","norm_bases":["BM20A","ČSN EN ISO 6888-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe, podziemne i technologiczne Metoda oznaczania liczby gronkowców koagulazododatnich metodą filtracji membranowej Vody pitné, povrchové, podzemní a technologické Metoda stanovení počtu koagulázopozitivních stafylokoků metodou membránové filtrace BM20A (ČSN EN ISO 6888-1) Wody przeznaczone do spozycia, powierzchniowe, podziemne i technologiczne Metoda oznaczania liczby gronkowcow koagulazododatnich metoda filtracji membranowej Vody pitne, povrchove, podzemni a technologicke Metoda stanoveni poctu koagulazopozitivnich stafylokoku metodou membranove filtrace BM20A (CSN EN ISO 6888-1)","search_en":"Drinking, surface, ground and process water Method for the enumeration of coagulase-positive staphylococci by membrane filtration BM20A (ČSN EN ISO 6888-1)","search_zh":"饮用水、地表水、地下水和工艺用水 膜过滤法测定凝固酶阳性葡萄球菌数 BM20A (ČSN EN ISO 6888-1)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":113,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dd2665cbbbffc5d7fb2b6ca4","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"115","test_object":"Wody przeznaczone do spożycia, podziemne, powierzchniowe i technologiczne","test_object_en":"Drinking, ground, surface and process water","test_object_zh":"饮用水、地下水、地表水和工艺用水","test_object_cs":"Vody pitné, podzemní, povrchové a technologické","methodology":"Oznaczanie Clostridium perfringens metodą filtracji membranowej","methodology_en":"Enumeration of Clostridium perfringens by membrane filtration","methodology_zh":"膜过滤法测定产气荚膜梭菌","methodology_cs":"Stanovení Clostridium perfringens metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Clostridium perfringens metodą filtracji membranowej","reference":"BM22A (ČSN EN ISO 14189)","norm_bases":["BM22A","ČSN EN ISO 14189"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, podziemne, powierzchniowe i technologiczne Oznaczanie Clostridium perfringens metodą filtracji membranowej Vody pitné, podzemní, povrchové a technologické Stanovení Clostridium perfringens metodou membránové filtrace BM22A (ČSN EN ISO 14189) Wody przeznaczone do spozycia, podziemne, powierzchniowe i technologiczne Oznaczanie Clostridium perfringens metoda filtracji membranowej Vody pitne, podzemni, povrchove a technologicke Stanoveni Clostridium perfringens metodou membranove filtrace BM22A (CSN EN ISO 14189)","search_en":"Drinking, ground, surface and process water Enumeration of Clostridium perfringens by membrane filtration BM22A (ČSN EN ISO 14189)","search_zh":"饮用水、地下水、地表水和工艺用水 膜过滤法测定产气荚膜梭菌 BM22A (ČSN EN ISO 14189)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":114,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ec042aa7fe2ab7a5bce028d0","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"116","test_object":"Wody powierzchniowe, ścieki i wody technologiczne","test_object_en":"Surface, waste and process water","test_object_zh":"地表水、废水和工艺用水","test_object_cs":"Vody povrchové, odpadní a technologické","methodology":"Oznaczanie zespołu obrostów metodą mikroskopową","methodology_en":"Determination of periphyton community by microscopy","methodology_zh":"显微镜法测定附着生物群落","methodology_cs":"Stanovení společenstva nárostů mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zespołu obrostów metodą mikroskopową","reference":"BT08A (ČSN 75 7715)","norm_bases":["BT08A","ČSN 75 7715"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe, ścieki i wody technologiczne Oznaczanie zespołu obrostów metodą mikroskopową Vody povrchové, odpadní a technologické Stanovení společenstva nárostů mikroskopicky BT08A (ČSN 75 7715) Wody powierzchniowe, scieki i wody technologiczne Oznaczanie zespolu obrostow metoda mikroskopowa Vody povrchove, odpadni a technologicke Stanoveni spolecenstva narostu mikroskopicky BT08A (CSN 75 7715)","search_en":"Surface, waste and process water Determination of periphyton community by microscopy BT08A (ČSN 75 7715)","search_zh":"地表水、废水和工艺用水 显微镜法测定附着生物群落 BT08A (ČSN 75 7715)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":115,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"12b772122744ef6c350de328","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"117","test_object":"Wody powierzchniowe płynące","test_object_en":"Surface running water","test_object_zh":"地表流水","test_object_cs":"Vody povrchové tekoucí","methodology":"Monitoring zespołu makrofitów w jednolitych częściach wód kategorii rzeka","methodology_en":"Monitoring of the macrophyte community of river water bodies","methodology_zh":"河流类水体大型水生植物群落监测","methodology_cs":"Sledování společenstva makrofyt vodních útvarů kategorie řeka","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Monitoring zespołu makrofitów w jednolitych częściach wód kategorii rzeka","reference":"BT11A (ČSN EN 14184; Grulich, V., Vydrová, A.: Metodika odběru a zpracování vzorků makrofyt tekoucích vod, VÚV, 2006)","norm_bases":["BT11A","ČSN EN 14184","Grulich, V., Vydrová, A.: Metodika odběru a zpracování vzorků makrofyt tekoucích vod, VÚV, 2006"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe płynące Monitoring zespołu makrofitów w jednolitych częściach wód kategorii rzeka Vody povrchové tekoucí Sledování společenstva makrofyt vodních útvarů kategorie řeka BT11A (ČSN EN 14184; Grulich, V., Vydrová, A.: Metodika odběru a zpracování vzorků makrofyt tekoucích vod, VÚV, 2006) Wody powierzchniowe plynace Monitoring zespolu makrofitow w jednolitych czesciach wod kategorii rzeka Vody povrchove tekouci Sledovani spolecenstva makrofyt vodnich utvaru kategorie reka BT11A (CSN EN 14184; Grulich, V., Vydrova, A.: Metodika odberu a zpracovani vzorku makrofyt tekoucich vod, VUV, 2006)","search_en":"Surface running water Monitoring of the macrophyte community of river water bodies BT11A (ČSN EN 14184; Grulich, V., Vydrová, A.: Metodika odběru a zpracování vzorků makrofyt tekoucích vod, VÚV, 2006)","search_zh":"地表流水 河流类水体大型水生植物群落监测 BT11A (ČSN EN 14184; Grulich, V., Vydrová, A.: Metodika odběru a zpracování vzorků makrofyt tekoucích vod, VÚV, 2006)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":116,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1e5221525c3fe05bb49c1a0a","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"118","test_object":"Wody powierzchniowe stojące","test_object_en":"Surface standing water","test_object_zh":"地表静水","test_object_cs":"Vody povrchové stojaté","methodology":"Oznaczanie zespołu fitoplanktonu w komorze do liczenia","methodology_en":"Determination of phytoplankton community in a counting chamber","methodology_zh":"计数室法测定浮游植物群落","methodology_cs":"Stanovení společenstva fytoplanktonu v počítací komůrce","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zespołu fitoplanktonu w komorze do liczenia","reference":"BT12A (ČSN EN 15204; Komárková, J.: Metodika odběru a zpracování vzorků fytoplanktonu stojatých vod, VÚV, 2006)","norm_bases":["BT12A","ČSN EN 15204","Komárková, J.: Metodika odběru a zpracování vzorků fytoplanktonu stojatých vod, VÚV, 2006"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe stojące Oznaczanie zespołu fitoplanktonu w komorze do liczenia Vody povrchové stojaté Stanovení společenstva fytoplanktonu v počítací komůrce BT12A (ČSN EN 15204; Komárková, J.: Metodika odběru a zpracování vzorků fytoplanktonu stojatých vod, VÚV, 2006) Wody powierzchniowe stojace Oznaczanie zespolu fitoplanktonu w komorze do liczenia Vody povrchove stojate Stanoveni spolecenstva fytoplanktonu v pocitaci komurce BT12A (CSN EN 15204; Komarkova, J.: Metodika odberu a zpracovani vzorku fytoplanktonu stojatych vod, VUV, 2006)","search_en":"Surface standing water Determination of phytoplankton community in a counting chamber BT12A (ČSN EN 15204; Komárková, J.: Metodika odběru a zpracování vzorků fytoplanktonu stojatých vod, VÚV, 2006)","search_zh":"地表静水 计数室法测定浮游植物群落 BT12A (ČSN EN 15204; Komárková, J.: Metodika odběru a zpracování vzorků fytoplanktonu stojatých vod, VÚV, 2006)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":117,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"929803e09e9f7bd3c9842b7b","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"119","test_object":"Wody powierzchniowe stojące","test_object_en":"Surface standing water","test_object_zh":"地表静水","test_object_cs":"Vody povrchové stojaté","methodology":"Monitoring zespołu makrofitów w jednolitych częściach wód kategorii jezioro","methodology_en":"Monitoring of the macrophyte community of lake water bodies","methodology_zh":"湖泊类水体大型水生植物群落监测","methodology_cs":"Sledování společenstva makrofyt vodních útvarů kategorie jezero","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Monitoring zespołu makrofitów w jednolitych częściach wód kategorii jezioro","reference":"BT16A (Chocholoušková, Z., Duras, J., Kučera, T.: Metodika odběru a zpracování vzorků makrofyt stojatých vod, VÚV, 2009)","norm_bases":["BT16A","Chocholoušková, Z., Duras, J., Kučera, T.: Metodika odběru a zpracování vzorků makrofyt stojatých vod, VÚV, 2009"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe stojące Monitoring zespołu makrofitów w jednolitych częściach wód kategorii jezioro Vody povrchové stojaté Sledování společenstva makrofyt vodních útvarů kategorie jezero BT16A (Chocholoušková, Z., Duras, J., Kučera, T.: Metodika odběru a zpracování vzorků makrofyt stojatých vod, VÚV, 2009) Wody powierzchniowe stojace Monitoring zespolu makrofitow w jednolitych czesciach wod kategorii jezioro Vody povrchove stojate Sledovani spolecenstva makrofyt vodnich utvaru kategorie jezero BT16A (Chocholouskova, Z., Duras, J., Kucera, T.: Metodika odberu a zpracovani vzorku makrofyt stojatych vod, VUV, 2009)","search_en":"Surface standing water Monitoring of the macrophyte community of lake water bodies BT16A (Chocholoušková, Z., Duras, J., Kučera, T.: Metodika odběru a zpracování vzorků makrofyt stojatých vod, VÚV, 2009)","search_zh":"地表静水 湖泊类水体大型水生植物群落监测 BT16A (Chocholoušková, Z., Duras, J., Kučera, T.: Metodika odběru a zpracování vzorků makrofyt stojatých vod, VÚV, 2009)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":118,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"12a57368f532d3702e9851f6","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"120","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Vody povrchové","methodology":"Oznaczanie zespołu makrozoobentosu jednolitych części wód kategorii rzeka i jezioro","methodology_en":"Determination of the macrozoobenthos community of river and lake water bodies","methodology_zh":"河流和湖泊类水体大型底栖动物群落测定","methodology_cs":"Stanovení společenstva makrozoobentosu vodních útvarů kategorie řeka a jezero","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zespołu makrozoobentosu jednolitych części wód kategorii rzeka i jezioro","reference":"BT21A (ČSN 75 7701; ČSN 75 7714; ČSN EN ISO 10870; Kokeš, J., Němejcová, D.: Metodika odběru a zpracování makrozoobentosu tekoucích vod metodou PERLA, VÚV, 2006; Němejcová, D. a kol.: Metodika odběru a zpracování vzorků makrozoobentosu velkých nebroditelných řek, VÚV, 2013; Adámek, Z.: Metodika odběru a zpracování vzorků makrozoobentosu stojatých vod, VÚV, 2006)","norm_bases":["BT21A","ČSN 75 7701","ČSN 75 7714","ČSN EN ISO 10870","Kokeš, J., Němejcová, D.: Metodika odběru a zpracování makrozoobentosu tekoucích vod metodou PERLA, VÚV, 2006","Němejcová, D. a kol.: Metodika odběru a zpracování vzorků makrozoobentosu velkých nebroditelných řek, VÚV, 2013","Adámek, Z.: Metodika odběru a zpracování vzorků makrozoobentosu stojatých vod, VÚV, 2006"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Oznaczanie zespołu makrozoobentosu jednolitych części wód kategorii rzeka i jezioro Vody povrchové Stanovení společenstva makrozoobentosu vodních útvarů kategorie řeka a jezero BT21A (ČSN 75 7701; ČSN 75 7714; ČSN EN ISO 10870; Kokeš, J., Němejcová, D.: Metodika odběru a zpracování makrozoobentosu tekoucích vod metodou PERLA, VÚV, 2006; Němejcová, D. a kol.: Metodika odběru a zpracování vzorků makrozoobentosu velkých nebroditelných řek, VÚV, 2013; Adámek, Z.: Metodika odběru a zpracování vzorků makrozoobentosu stojatých vod, VÚV, 2006) Wody powierzchniowe Oznaczanie zespolu makrozoobentosu jednolitych czesci wod kategorii rzeka i jezioro Vody povrchove Stanoveni spolecenstva makrozoobentosu vodnich utvaru kategorie reka a jezero BT21A (CSN 75 7701; CSN 75 7714; CSN EN ISO 10870; Kokes, J., Nemejcova, D.: Metodika odberu a zpracovani makrozoobentosu tekoucich vod metodou PERLA, VUV, 2006; Nemejcova, D. a kol.: Metodika odberu a zpracovani vzorku makrozoobentosu velkych nebroditelnych rek, VUV, 2013; Adamek, Z.: Metodika odberu a zpracovani vzorku makrozoobentosu stojatych vod, VUV, 2006)","search_en":"Surface water Determination of the macrozoobenthos community of river and lake water bodies BT21A (ČSN 75 7701; ČSN 75 7714; ČSN EN ISO 10870; Kokeš, J., Němejcová, D.: Metodika odběru a zpracování makrozoobentosu tekoucích vod metodou PERLA, VÚV, 2006; Němejcová, D. a kol.: Metodika odběru a zpracování vzorků makrozoobentosu velkých nebroditelných řek, VÚV, 2013; Adámek, Z.: Metodika odběru a zpracování vzorků makrozoobentosu stojatých vod, VÚV, 2006)","search_zh":"地表水 河流和湖泊类水体大型底栖动物群落测定 BT21A (ČSN 75 7701; ČSN 75 7714; ČSN EN ISO 10870; Kokeš, J., Němejcová, D.: Metodika odběru a zpracování makrozoobentosu tekoucích vod metodou PERLA, VÚV, 2006; Němejcová, D. a kol.: Metodika odběru a zpracování vzorků makrozoobentosu velkých nebroditelných řek, VÚV, 2013; Adámek, Z.: Metodika odběru a zpracování vzorků makrozoobentosu stojatých vod, VÚV, 2006)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":119,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ba9285a7d4d17fdacc007cfd","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"121","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Vody povrchové","methodology":"Oznaczanie zespołu fitobentosu jednolitych części wód kategorii rzeka i jezioro","methodology_en":"Determination of the phytobenthos community of river and lake water bodies","methodology_zh":"河流和湖泊类水体底栖植物群落测定","methodology_cs":"Stanovení společenstva fytobentosu vodních útvarů kategorie řeka a jezero","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zespołu fitobentosu jednolitych części wód kategorii rzeka i jezioro","reference":"BT22A (ČSN EN 13946; ČSN EN 14407; ČSN 75 7715; Marvan, P., Heteša, J.: Metodika odběru a zpracování vzorků fytobentosu tekoucích vod. VÚV, 2006; Marvan, P., Kozáková, M.: Metodika odběru a zpracování vzorků fytobentosu stojatých vod, VÚV, 2006)","norm_bases":["BT22A","ČSN EN 13946","ČSN EN 14407","ČSN 75 7715","Marvan, P., Heteša, J.: Metodika odběru a zpracování vzorků fytobentosu tekoucích vod. VÚV, 2006","Marvan, P., Kozáková, M.: Metodika odběru a zpracování vzorků fytobentosu stojatých vod, VÚV, 2006"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Oznaczanie zespołu fitobentosu jednolitych części wód kategorii rzeka i jezioro Vody povrchové Stanovení společenstva fytobentosu vodních útvarů kategorie řeka a jezero BT22A (ČSN EN 13946; ČSN EN 14407; ČSN 75 7715; Marvan, P., Heteša, J.: Metodika odběru a zpracování vzorků fytobentosu tekoucích vod. VÚV, 2006; Marvan, P., Kozáková, M.: Metodika odběru a zpracování vzorků fytobentosu stojatých vod, VÚV, 2006) Wody powierzchniowe Oznaczanie zespolu fitobentosu jednolitych czesci wod kategorii rzeka i jezioro Vody povrchove Stanoveni spolecenstva fytobentosu vodnich utvaru kategorie reka a jezero BT22A (CSN EN 13946; CSN EN 14407; CSN 75 7715; Marvan, P., Hetesa, J.: Metodika odberu a zpracovani vzorku fytobentosu tekoucich vod. VUV, 2006; Marvan, P., Kozakova, M.: Metodika odberu a zpracovani vzorku fytobentosu stojatych vod, VUV, 2006)","search_en":"Surface water Determination of the phytobenthos community of river and lake water bodies BT22A (ČSN EN 13946; ČSN EN 14407; ČSN 75 7715; Marvan, P., Heteša, J.: Metodika odběru a zpracování vzorků fytobentosu tekoucích vod. VÚV, 2006; Marvan, P., Kozáková, M.: Metodika odběru a zpracování vzorků fytobentosu stojatých vod, VÚV, 2006)","search_zh":"地表水 河流和湖泊类水体底栖植物群落测定 BT22A (ČSN EN 13946; ČSN EN 14407; ČSN 75 7715; Marvan, P., Heteša, J.: Metodika odběru a zpracování vzorků fytobentosu tekoucích vod. VÚV, 2006; Marvan, P., Kozáková, M.: Metodika odběru a zpracování vzorků fytobentosu stojatých vod, VÚV, 2006)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":120,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4a0cb24afef3c519d45fac97","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"122","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Vody povrchové","methodology":"Oznaczanie zespołu zooplanktonu jednolitych części wód kategorii jezioro","methodology_en":"Determination of the zooplankton community of lake water bodies","methodology_zh":"湖泊类水体浮游动物群落测定","methodology_cs":"Stanovení společenstva zooplanktonu vodních útvarů kategorie jezero","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zespołu zooplanktonu jednolitych części wód kategorii jezioro","reference":"BT23A (ČSN EN 15110; Přikryl, I.: Metodika odběru a zpracování vzorků zooplanktonu stojatých vod, VÚV, 2006)","norm_bases":["BT23A","ČSN EN 15110","Přikryl, I.: Metodika odběru a zpracování vzorků zooplanktonu stojatých vod, VÚV, 2006"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Oznaczanie zespołu zooplanktonu jednolitych części wód kategorii jezioro Vody povrchové Stanovení společenstva zooplanktonu vodních útvarů kategorie jezero BT23A (ČSN EN 15110; Přikryl, I.: Metodika odběru a zpracování vzorků zooplanktonu stojatých vod, VÚV, 2006) Wody powierzchniowe Oznaczanie zespolu zooplanktonu jednolitych czesci wod kategorii jezioro Vody povrchove Stanoveni spolecenstva zooplanktonu vodnich utvaru kategorie jezero BT23A (CSN EN 15110; Prikryl, I.: Metodika odberu a zpracovani vzorku zooplanktonu stojatych vod, VUV, 2006)","search_en":"Surface water Determination of the zooplankton community of lake water bodies BT23A (ČSN EN 15110; Přikryl, I.: Metodika odběru a zpracování vzorků zooplanktonu stojatých vod, VÚV, 2006)","search_zh":"地表水 湖泊类水体浮游动物群落测定 BT23A (ČSN EN 15110; Přikryl, I.: Metodika odběru a zpracování vzorků zooplanktonu stojatých vod, VÚV, 2006)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":121,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"824234bc831f678440e0ff47","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"1","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Pobieranie próbki prostej ścieków (pobór ręczny)","methodology_en":"Collection of a spot sample of waste water (manual sampling)","methodology_zh":"废水瞬时样采集（人工采样）","methodology_cs":"Odběr prostého vzorku odpadních vod (manuální odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbki prostej ścieków (pobór ręczny)","reference":"VV01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","norm_bases":["VV01","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14","ČSN 75 7315"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbki prostej ścieków (pobór ręczny) Odpadní vody Odběr prostého vzorku odpadních vod (manuální odběr) VV01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) Scieki Pobieranie probki prostej sciekow (pobor reczny) Odpadni vody Odber prosteho vzorku odpadnich vod (manualni odber) VV01 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14; CSN 75 7315)","search_en":"Waste water Collection of a spot sample of waste water (manual sampling) VV01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","search_zh":"废水 废水瞬时样采集（人工采样） VV01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":122,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"edb3ecebfb48b41b32f38f24","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"2","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Pobieranie próbki zmieszanej ścieków proporcjonalnej do czasu (pobór automatycznym próbnikiem lub ręczny)","methodology_en":"Collection of a time-proportional composite sample of waste water (automatic sampler or manual sampling)","methodology_zh":"废水时间比例混合样采集（自动采样器或人工采样）","methodology_cs":"Odběr směsného časově závislého vzorku odpadních vod (odběr automatickým vzorkovačem příp. odběr manuální)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbki zmieszanej ścieków proporcjonalnej do czasu (pobór automatycznym próbnikiem lub ręczny)","reference":"VV02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","norm_bases":["VV02","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14","ČSN 75 7315"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbki zmieszanej ścieków proporcjonalnej do czasu (pobór automatycznym próbnikiem lub ręczny) Odpadní vody Odběr směsného časově závislého vzorku odpadních vod (odběr automatickým vzorkovačem příp. odběr manuální) VV02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) Scieki Pobieranie probki zmieszanej sciekow proporcjonalnej do czasu (pobor automatycznym probnikiem lub reczny) Odpadni vody Odber smesneho casove zavisleho vzorku odpadnich vod (odber automatickym vzorkovacem prip. odber manualni) VV02 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14; CSN 75 7315)","search_en":"Waste water Collection of a time-proportional composite sample of waste water (automatic sampler or manual sampling) VV02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","search_zh":"废水 废水时间比例混合样采集（自动采样器或人工采样） VV02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":123,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2fe6f2d2cc18e8bd0d660833","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"3","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Pobieranie próbki zmieszanej ścieków proporcjonalnej do przepływu (pobór automatycznym próbnikiem)","methodology_en":"Collection of a flow-proportional composite sample of waste water (automatic sampler)","methodology_zh":"废水流量比例混合样采集（自动采样器）","methodology_cs":"Odběr směsného průtokově závislého vzorku odpadních vod (odběr automatickým vzorkovačem)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbki zmieszanej ścieków proporcjonalnej do przepływu (pobór automatycznym próbnikiem)","reference":"VV03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","norm_bases":["VV03","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbki zmieszanej ścieków proporcjonalnej do przepływu (pobór automatycznym próbnikiem) Odpadní vody Odběr směsného průtokově závislého vzorku odpadních vod (odběr automatickým vzorkovačem) VV03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14) Scieki Pobieranie probki zmieszanej sciekow proporcjonalnej do przeplywu (pobor automatycznym probnikiem) Odpadni vody Odber smesneho prutokove zavisleho vzorku odpadnich vod (odber automatickym vzorkovacem) VV03 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14)","search_en":"Waste water Collection of a flow-proportional composite sample of waste water (automatic sampler) VV03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","search_zh":"废水 废水流量比例混合样采集（自动采样器） VV03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":124,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"55ddafd968be0dfd46072c9c","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"4","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchové vody","methodology":"Pobieranie próbek ze zbiorników wodnych","methodology_en":"Sampling from water reservoirs","methodology_zh":"水库采样","methodology_cs":"Odběr vzorku z vodních nádrží","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ze zbiorników wodnych","reference":"VV05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","norm_bases":["VV05","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-4","ČSN EN ISO 5667-14","ČSN EN ISO 19458"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Pobieranie próbek ze zbiorników wodnych Povrchové vody Odběr vzorku z vodních nádrží VV05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-14; ČSN EN ISO 19458) Wody powierzchniowe Pobieranie probek ze zbiornikow wodnych Povrchove vody Odber vzorku z vodnich nadrzi VV05 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-4; CSN EN ISO 5667-14; CSN EN ISO 19458)","search_en":"Surface water Sampling from water reservoirs VV05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","search_zh":"地表水 水库采样 VV05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":125,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e17278004fe8bee82b48b70d","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"5","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchové vody","methodology":"Pobieranie próbek z rzek i potoków","methodology_en":"Sampling from rivers and streams","methodology_zh":"河流和溪流采样","methodology_cs":"Odběr vzorku z řek a potoků","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek z rzek i potoków","reference":"VV06 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","norm_bases":["VV06","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-6","ČSN EN ISO 5667-14","ČSN EN ISO 19458"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Pobieranie próbek z rzek i potoków Povrchové vody Odběr vzorku z řek a potoků VV06 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458) Wody powierzchniowe Pobieranie probek z rzek i potokow Povrchove vody Odber vzorku z rek a potoku VV06 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-6; CSN EN ISO 5667-14; CSN EN ISO 19458)","search_en":"Surface water Sampling from rivers and streams VV06 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","search_zh":"地表水 河流和溪流采样 VV06 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":126,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"76770a44f5f4a9a512f169b1","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"6","test_object":"Wody przeznaczone do spożycia","test_object_en":"Drinking water","test_object_zh":"饮用水","test_object_cs":"Pitné vody","methodology":"Pobieranie próbek wody przeznaczonej do spożycia","methodology_en":"Sampling of drinking water","methodology_zh":"饮用水采样","methodology_cs":"Odběr vzorku pitné vody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wody przeznaczonej do spożycia","reference":"VV07 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","norm_bases":["VV07","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-5","ČSN ISO 5667-11","ČSN EN ISO 5667-14","ČSN EN ISO 19458"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia Pobieranie próbek wody przeznaczonej do spożycia Pitné vody Odběr vzorku pitné vody VV07 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458) Wody przeznaczone do spozycia Pobieranie probek wody przeznaczonej do spozycia Pitne vody Odber vzorku pitne vody VV07 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-5; CSN ISO 5667-11; CSN EN ISO 5667-14; CSN EN ISO 19458)","search_en":"Drinking water Sampling of drinking water VV07 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","search_zh":"饮用水 饮用水采样 VV07 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":127,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a72332c1012d1da38063051f","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"7","test_object":"Osad denny, grunty","test_object_en":"Sediment, earths","test_object_zh":"沉积物、土","test_object_cs":"Sediment, zeminy","methodology":"Pobieranie próbek osadu dennego","methodology_en":"Sampling of bottom sediment","methodology_zh":"底部沉积物采样","methodology_cs":"Odběr vzorku dnového sedimentu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek osadu dennego","reference":"VS01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)","norm_bases":["VS01","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-12","ČSN EN ISO 5667-14","ČSN EN ISO 5667-15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad denny, grunty Pobieranie próbek osadu dennego Sediment, zeminy Odběr vzorku dnového sedimentu VS01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15) Osad denny, grunty Pobieranie probek osadu dennego Sediment, zeminy Odber vzorku dnoveho sedimentu VS01 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-12; CSN EN ISO 5667-14; CSN EN ISO 5667-15)","search_en":"Sediment, earths Sampling of bottom sediment VS01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)","search_zh":"沉积物、土 底部沉积物采样 VS01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":128,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3f0cf529208d8b6ef49f3299","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"8","test_object":"Osady","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kaly","methodology":"Pobieranie próbek osadów z oczyszczalni ścieków i stacji uzdatniania wody","methodology_en":"Sampling of sludge from wastewater treatment plants and water treatment plants","methodology_zh":"污水处理厂和水厂污泥采样","methodology_cs":"Odběr vzorků kalů z čistíren a úpraven vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek osadów z oczyszczalni ścieków i stacji uzdatniania wody","reference":"VK01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14)","norm_bases":["VK01","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-13","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady Pobieranie próbek osadów z oczyszczalni ścieków i stacji uzdatniania wody Kaly Odběr vzorků kalů z čistíren a úpraven vod VK01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14) Osady Pobieranie probek osadow z oczyszczalni sciekow i stacji uzdatniania wody Kaly Odber vzorku kalu z cistiren a upraven vod VK01 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-13; CSN EN ISO 5667-14)","search_en":"Sludge Sampling of sludge from wastewater treatment plants and water treatment plants VK01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14)","search_zh":"污泥 污水处理厂和水厂污泥采样 VK01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":129,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"171b28304c95305ee161e877","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"9","test_object":"Odpady pastowate, stałe i ciekłe","test_object_en":"Paste-like, solid and liquid waste","test_object_zh":"膏状、固体和液体废物","test_object_cs":"Pastovité, tuhé a kapalné odpady","methodology":"Pobieranie próbek odpadów","methodology_en":"Sampling of waste","methodology_zh":"废物采样","methodology_cs":"Odběr vzorku odpadu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek odpadów","reference":"VO01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN 14899; ČSN 01 5111; ČSN 01 5112; Metodický pokyn MŽP č. 6 ke vzorkování odpadů, Věstník MŽP, částka 4, duben 2008)","norm_bases":["VO01","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-14","ČSN EN 14899","ČSN 01 5111","ČSN 01 5112","Metodický pokyn MŽP č. 6 ke vzorkování odpadů, Věstník MŽP, částka 4, duben 2008"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Odpady pastowate, stałe i ciekłe Pobieranie próbek odpadów Pastovité, tuhé a kapalné odpady Odběr vzorku odpadu VO01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN 14899; ČSN 01 5111; ČSN 01 5112; Metodický pokyn MŽP č. 6 ke vzorkování odpadů, Věstník MŽP, částka 4, duben 2008) Odpady pastowate, stale i ciekle Pobieranie probek odpadow Pastovite, tuhe a kapalne odpady Odber vzorku odpadu VO01 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-14; CSN EN 14899; CSN 01 5111; CSN 01 5112; Metodicky pokyn MZP c. 6 ke vzorkovani odpadu, Vestnik MZP, castka 4, duben 2008)","search_en":"Paste-like, solid and liquid waste Sampling of waste VO01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN 14899; ČSN 01 5111; ČSN 01 5112; Metodický pokyn MŽP č. 6 ke vzorkování odpadů, Věstník MŽP, částka 4, duben 2008)","search_zh":"膏状、固体和液体废物 废物采样 VO01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN 14899; ČSN 01 5111; ČSN 01 5112; Metodický pokyn MŽP č. 6 ke vzorkování odpadů, Věstník MŽP, částka 4, duben 2008)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":130,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"17e19492ed6173ff1afcb3a1","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"10","test_object":"Wody powierzchniowe i podziemne","test_object_en":"Surface and ground water","test_object_zh":"地表水和地下水","test_object_cs":"Povrchové a podzemní vody","methodology":"Pobieranie próbek wody surowej","methodology_en":"Sampling of raw water","methodology_zh":"原水采样","methodology_cs":"Odběr vzorku surové vody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wody surowej","reference":"VV09 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","norm_bases":["VV09","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-4","ČSN ISO 5667-5","ČSN ISO 5667-11","ČSN EN ISO 5667-14","ČSN EN ISO 19458"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe i podziemne Pobieranie próbek wody surowej Povrchové a podzemní vody Odběr vzorku surové vody VV09 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458) Wody powierzchniowe i podziemne Pobieranie probek wody surowej Povrchove a podzemni vody Odber vzorku surove vody VV09 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-4; CSN ISO 5667-5; CSN ISO 5667-11; CSN EN ISO 5667-14; CSN EN ISO 19458)","search_en":"Surface and ground water Sampling of raw water VV09 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","search_zh":"地表水和地下水 原水采样 VV09 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":131,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0c6a56cb9ea9441a2521ae24","lab_id":"69ad52a4de79e566650fd32c","country":"CZ","accr_number":"1264","accr_body":"ČIA","row_label":"11","test_object":"Wody przeznaczone do spożycia, powierzchniowe i ścieki","test_object_en":"Drinking, surface and waste water","test_object_zh":"饮用水、地表水和废水","test_object_cs":"Pitné, povrchové a odpadní vody","methodology":"Pobieranie próbek wód za pomocą próbnika pasywnego","methodology_en":"Water sampling using a passive sampler","methodology_zh":"被动采样器水样采集","methodology_cs":"Odběr vzorku vod pomocí pasivního vzorkovače","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód za pomocą próbnika pasywnego","reference":"VV10 (ČSN EN ISO 5667-23)","norm_bases":["VV10","ČSN EN ISO 5667-23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, powierzchniowe i ścieki Pobieranie próbek wód za pomocą próbnika pasywnego Pitné, povrchové a odpadní vody Odběr vzorku vod pomocí pasivního vzorkovače VV10 (ČSN EN ISO 5667-23) Wody przeznaczone do spozycia, powierzchniowe i scieki Pobieranie probek wod za pomoca probnika pasywnego Pitne, povrchove a odpadni vody Odber vzorku vod pomoci pasivniho vzorkovace VV10 (CSN EN ISO 5667-23)","search_en":"Drinking, surface and waste water Water sampling using a passive sampler VV10 (ČSN EN ISO 5667-23)","search_zh":"饮用水、地表水和废水 被动采样器水样采集 VV10 (ČSN EN ISO 5667-23)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":132,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}