{"lab":{"_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","address":"Smetanova 195, Sedlec, 332 02 Starý Plzenec","categories":["water","microbiology"],"city":"Starý Plzenec","imported_at":"2026-03-08T10:42:44.590Z","methods_count":37,"name":"KANALIZACE A VODOVODY Starý Plzenec, a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1260_585_2024_CS.pdf","1260_585_2024_EN.pdf"],"scope_summary":"Analiza chemiczna i mikrobiologiczna wód oraz pobieranie próbek.","search_text":"kanalizace a vodovody starý plzenec, a.s. smetanova 195, sedlec, 332 02 starý plzenec 1260","status":"active","updated_at":"2026-03-08T14:52:09.793Z","valid_from":"","valid_until":"11-05-2028","website":"www.kav-plzenec.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.kav-plzenec.cz","map_coord":[49.693907,13.485766],"map_geo":"nominatim-street","certificate_date":"04.11.2024","certificate_no":"585/2024","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Analiza chemiczna i mikrobiologiczna wód oraz pobieranie próbek.","en":"Chemical and microbiological analysis of waters and sampling.","zh":"水的化学和微生物分析以及采样。","cs":"Chemický a mikrobiologický rozbor vod a odběr vzorků."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Kanalizacji i Wodociągów Starý Plzenec","lab_division_cs":"Laboratoř Kanalizací a vodovodů Starý Plzenec","lab_division_en":"Laboratory of Sewerage and Waterworks Starý Plzenec","lab_division_zh":"旧比尔森排水与供水实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"9cbd8305ddf75a97eb20db60e89df16f9864b8948797f713ce82b53c3b78ea40","source_pdf_url":"https://www.cai.cz/OA/pdf/P585_2024_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"bf0dfb3bd1cf9dc13fbfb65c","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"1","test_object":"Woda pitna, woda surowa, woda w kąpieliskach (baseny)","test_object_en":"Drinking water, raw water, bathing water (swimming pools)","test_object_zh":"饮用水、原水、游泳用水（游泳池）","test_object_cs":"Pitná voda, surová voda, voda ke koupání (bazény)","methodology":"Oznaczanie Escherichia coli i bakterii grupy coli (metodą Colilert-18/QT)","methodology_en":"Determination of Escherichia coli and coliform bacteria (Colilert-18/QT method)","methodology_zh":"大肠埃希氏菌和大肠菌群的测定（Colilert-18/QT法）","methodology_cs":"Stanovení Escherichia coli a koliformních bakterií (metodou Colilert –18/QT)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda Colilert-18/QT","technique_en":"Colilert-18/QT method","technique_zh":"Colilert-18/QT法","technique_cs":"metodou Colilert –18/QT","techniques":["metoda Colilert-18/QT"],"techniques_en":["Colilert-18/QT method"],"techniques_zh":["Colilert-18/QT法"],"techniques_cs":["metodou Colilert –18/QT"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Escherichia coli i bakterii grupy coli (metodą Colilert-18/QT)\nmetoda Colilert-18/QT","reference":"SOP č. 41 (Návod k Colilert – 18/QT; ČSN EN ISO 9308-2)","norm_bases":["SOP č. 41","Návod k Colilert – 18/QT","ČSN EN ISO 9308-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, woda w kąpieliskach (baseny) Oznaczanie Escherichia coli i bakterii grupy coli (metodą Colilert-18/QT) metoda Colilert-18/QT Pitná voda, surová voda, voda ke koupání (bazény) Stanovení Escherichia coli a koliformních bakterií (metodou Colilert –18/QT) metodou Colilert –18/QT SOP č. 41 (Návod k Colilert – 18/QT; ČSN EN ISO 9308-2) Woda pitna, woda surowa, woda w kapieliskach (baseny) Oznaczanie Escherichia coli i bakterii grupy coli (metoda Colilert-18/QT) metoda Colilert-18/QT Pitna voda, surova voda, voda ke koupani (bazeny) Stanoveni Escherichia coli a koliformnich bakterii (metodou Colilert –18/QT) metodou Colilert –18/QT SOP c. 41 (Navod k Colilert – 18/QT; CSN EN ISO 9308-2)","search_en":"Drinking water, raw water, bathing water (swimming pools) Determination of Escherichia coli and coliform bacteria (Colilert-18/QT method) Colilert-18/QT method SOP č. 41 (Návod k Colilert – 18/QT; ČSN EN ISO 9308-2)","search_zh":"饮用水、原水、游泳用水（游泳池） 大肠埃希氏菌和大肠菌群的测定（Colilert-18/QT法） Colilert-18/QT法 SOP č. 41 (Návod k Colilert – 18/QT; ČSN EN ISO 9308-2)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9dd876b29d2e58febeaa30fa","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"2","test_object":"Woda pitna, woda surowa, woda w kąpieliskach (baseny)","test_object_en":"Drinking water, raw water, bathing water (swimming pools)","test_object_zh":"饮用水、原水、游泳用水（游泳池）","test_object_cs":"Pitná voda, surová voda, voda ke koupání (bazény)","methodology":"Oznaczanie mikroorganizmów hodowlanych w 36 °C i w 22 °C – metodą posiewu wgłębnego do agaru odżywczego","methodology_en":"Enumeration of culturable micro-organisms at 36 °C and at 22 °C – by inoculation in a nutrient agar culture medium","methodology_zh":"36 °C和22 °C可培养微生物的测定 – 营养琼脂培养基接种法","methodology_cs":"Stanovení kultivovatelných mikroorganismů při 36 °C a při 22 °C - metodou očkování do živného agarového kultivačního media","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"posiew wgłębny do agaru odżywczego","technique_en":"inoculation in a nutrient agar culture medium","technique_zh":"营养琼脂培养基接种法","technique_cs":"metodou očkování do živného agarového kultivačního media","techniques":["posiew wgłębny do agaru odżywczego"],"techniques_en":["inoculation in a nutrient agar culture medium"],"techniques_zh":["营养琼脂培养基接种法"],"techniques_cs":["metodou očkování do živného agarového kultivačního media"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mikroorganizmów hodowlanych w 36 °C i w 22 °C – metodą posiewu wgłębnego do agaru odżywczego\nposiew wgłębny do agaru odżywczego","reference":"SOP č. 03 (ČSN EN ISO 6222)","norm_bases":["SOP č. 03","ČSN EN ISO 6222"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, woda w kąpieliskach (baseny) Oznaczanie mikroorganizmów hodowlanych w 36 °C i w 22 °C – metodą posiewu wgłębnego do agaru odżywczego posiew wgłębny do agaru odżywczego Pitná voda, surová voda, voda ke koupání (bazény) Stanovení kultivovatelných mikroorganismů při 36 °C a při 22 °C - metodou očkování do živného agarového kultivačního media metodou očkování do živného agarového kultivačního media SOP č. 03 (ČSN EN ISO 6222) Woda pitna, woda surowa, woda w kapieliskach (baseny) Oznaczanie mikroorganizmow hodowlanych w 36 °C i w 22 °C – metoda posiewu wglebnego do agaru odzywczego posiew wglebny do agaru odzywczego Pitna voda, surova voda, voda ke koupani (bazeny) Stanoveni kultivovatelnych mikroorganismu pri 36 °C a pri 22 °C - metodou ockovani do zivneho agaroveho kultivacniho media metodou ockovani do zivneho agaroveho kultivacniho media SOP c. 03 (CSN EN ISO 6222)","search_en":"Drinking water, raw water, bathing water (swimming pools) Enumeration of culturable micro-organisms at 36 °C and at 22 °C – by inoculation in a nutrient agar culture medium inoculation in a nutrient agar culture medium SOP č. 03 (ČSN EN ISO 6222)","search_zh":"饮用水、原水、游泳用水（游泳池） 36 °C和22 °C可培养微生物的测定 – 营养琼脂培养基接种法 营养琼脂培养基接种法 SOP č. 03 (ČSN EN ISO 6222)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2681ff7e6a85f7d2e71690b5","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"3","test_object":"Woda pitna, woda surowa","test_object_en":"Drinking water, raw water","test_object_zh":"饮用水、原水","test_object_cs":"Pitná voda, surová voda","methodology":"Oznaczanie enterokoków jelitowych – metodą filtracji membranowej","methodology_en":"Enumeration of intestinal enterococci – membrane filtration method","methodology_zh":"肠球菌的测定 – 膜过滤法","methodology_cs":"Stanovení intestinálních enterokoků - metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda filtracji membranowej","technique_en":"membrane filtration method","technique_zh":"膜过滤法","technique_cs":"metodou membránové filtrace","techniques":["metoda filtracji membranowej"],"techniques_en":["membrane filtration method"],"techniques_zh":["膜过滤法"],"techniques_cs":["metodou membránové filtrace"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie enterokoków jelitowych – metodą filtracji membranowej\nmetoda filtracji membranowej","reference":"SOP č. 06 (ČSN EN ISO 7899–2)","norm_bases":["SOP č. 06","ČSN EN ISO 7899–2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa Oznaczanie enterokoków jelitowych – metodą filtracji membranowej metoda filtracji membranowej Pitná voda, surová voda Stanovení intestinálních enterokoků - metodou membránové filtrace metodou membránové filtrace SOP č. 06 (ČSN EN ISO 7899–2) Woda pitna, woda surowa Oznaczanie enterokokow jelitowych – metoda filtracji membranowej metoda filtracji membranowej Pitna voda, surova voda Stanoveni intestinalnich enterokoku - metodou membranove filtrace metodou membranove filtrace SOP c. 06 (CSN EN ISO 7899–2)","search_en":"Drinking water, raw water Enumeration of intestinal enterococci – membrane filtration method membrane filtration method SOP č. 06 (ČSN EN ISO 7899–2)","search_zh":"饮用水、原水 肠球菌的测定 – 膜过滤法 膜过滤法 SOP č. 06 (ČSN EN ISO 7899–2)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b6bbbb75a19881a1770970df","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"4","test_object":"Woda pitna, woda surowa, woda w kąpieliskach (baseny)","test_object_en":"Drinking water, raw water, bathing water (swimming pools)","test_object_zh":"饮用水、原水、游泳用水（游泳池）","test_object_cs":"Pitná voda, surová voda, voda ke koupání (bazény)","methodology":"Oznaczanie Pseudomonas aeruginosa – metodą filtracji membranowej","methodology_en":"Enumeration of Pseudomonas aeruginosa – membrane filtration method","methodology_zh":"铜绿假单胞菌的测定 – 膜过滤法","methodology_cs":"Stanovení Pseudomonas aeruginosa – metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda filtracji membranowej","technique_en":"membrane filtration method","technique_zh":"膜过滤法","technique_cs":"metodou membránové filtrace","techniques":["metoda filtracji membranowej"],"techniques_en":["membrane filtration method"],"techniques_zh":["膜过滤法"],"techniques_cs":["metodou membránové filtrace"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Pseudomonas aeruginosa – metodą filtracji membranowej\nmetoda filtracji membranowej","reference":"SOP č. 09 (ČSN EN ISO 16266)","norm_bases":["SOP č. 09","ČSN EN ISO 16266"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, woda w kąpieliskach (baseny) Oznaczanie Pseudomonas aeruginosa – metodą filtracji membranowej metoda filtracji membranowej Pitná voda, surová voda, voda ke koupání (bazény) Stanovení Pseudomonas aeruginosa – metodou membránové filtrace metodou membránové filtrace SOP č. 09 (ČSN EN ISO 16266) Woda pitna, woda surowa, woda w kapieliskach (baseny) Oznaczanie Pseudomonas aeruginosa – metoda filtracji membranowej metoda filtracji membranowej Pitna voda, surova voda, voda ke koupani (bazeny) Stanoveni Pseudomonas aeruginosa – metodou membranove filtrace metodou membranove filtrace SOP c. 09 (CSN EN ISO 16266)","search_en":"Drinking water, raw water, bathing water (swimming pools) Enumeration of Pseudomonas aeruginosa – membrane filtration method membrane filtration method SOP č. 09 (ČSN EN ISO 16266)","search_zh":"饮用水、原水、游泳用水（游泳池） 铜绿假单胞菌的测定 – 膜过滤法 膜过滤法 SOP č. 09 (ČSN EN ISO 16266)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b7bc9299b9da23ab4514a6b6","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"5","test_object":"Woda pitna, woda surowa","test_object_en":"Drinking water, raw water","test_object_zh":"饮用水、原水","test_object_cs":"Pitná voda, surová voda","methodology":"Oznaczanie termotolerancyjnych bakterii grupy coli – metodą filtracji membranowej","methodology_en":"Enumeration of thermotolerant coliform bacteria – membrane filtration method","methodology_zh":"耐热大肠菌群的测定 – 膜过滤法","methodology_cs":"Stanovení termotolerantních koliformních bakterií - metodou membránové filtrace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda filtracji membranowej","technique_en":"membrane filtration method","technique_zh":"膜过滤法","technique_cs":"metodou membránové filtrace","techniques":["metoda filtracji membranowej"],"techniques_en":["membrane filtration method"],"techniques_zh":["膜过滤法"],"techniques_cs":["metodou membránové filtrace"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie termotolerancyjnych bakterii grupy coli – metodą filtracji membranowej\nmetoda filtracji membranowej","reference":"SOP č. 32 (ČSN 75 7835)","norm_bases":["SOP č. 32","ČSN 75 7835"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa Oznaczanie termotolerancyjnych bakterii grupy coli – metodą filtracji membranowej metoda filtracji membranowej Pitná voda, surová voda Stanovení termotolerantních koliformních bakterií - metodou membránové filtrace metodou membránové filtrace SOP č. 32 (ČSN 75 7835) Woda pitna, woda surowa Oznaczanie termotolerancyjnych bakterii grupy coli – metoda filtracji membranowej metoda filtracji membranowej Pitna voda, surova voda Stanoveni termotolerantnich koliformnich bakterii - metodou membranove filtrace metodou membranove filtrace SOP c. 32 (CSN 75 7835)","search_en":"Drinking water, raw water Enumeration of thermotolerant coliform bacteria – membrane filtration method membrane filtration method SOP č. 32 (ČSN 75 7835)","search_zh":"饮用水、原水 耐热大肠菌群的测定 – 膜过滤法 膜过滤法 SOP č. 32 (ČSN 75 7835)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"906f023d11b4b037cd730662","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"7","test_object":"Woda pitna, woda surowa, ścieki, woda w kąpieliskach (baseny)","test_object_en":"Drinking water, raw water, waste water, bathing water (swimming pools)","test_object_zh":"饮用水、原水、废水、游泳用水（游泳池）","test_object_cs":"Pitná voda, surová voda, odpadní voda, voda ke koupání (bazény)","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda potencjometryczna","technique_en":"potentiometric method","technique_zh":"电位法","technique_cs":"potenciometricky","techniques":["metoda potencjometryczna"],"techniques_en":["potentiometric method"],"techniques_zh":["电位法"],"techniques_cs":["potenciometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną\nmetoda potencjometryczna","reference":"SOP č. 01 (ČSN ISO 10523)","norm_bases":["SOP č. 01","ČSN ISO 10523"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, ścieki, woda w kąpieliskach (baseny) Oznaczanie pH metodą potencjometryczną metoda potencjometryczna Pitná voda, surová voda, odpadní voda, voda ke koupání (bazény) Stanovení pH potenciometricky potenciometricky SOP č. 01 (ČSN ISO 10523) Woda pitna, woda surowa, scieki, woda w kapieliskach (baseny) Oznaczanie pH metoda potencjometryczna metoda potencjometryczna Pitna voda, surova voda, odpadni voda, voda ke koupani (bazeny) Stanoveni pH potenciometricky potenciometricky SOP c. 01 (CSN ISO 10523)","search_en":"Drinking water, raw water, waste water, bathing water (swimming pools) Determination of pH by potentiometry potentiometric method SOP č. 01 (ČSN ISO 10523)","search_zh":"饮用水、原水、废水、游泳用水（游泳池） 电位法测定pH 电位法 SOP č. 01 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7d7088b032936242d8200d5b","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"8","test_object":"Woda pitna, woda surowa","test_object_en":"Drinking water, raw water","test_object_zh":"饮用水、原水","test_object_cs":"Pitná voda, surová voda","methodology":"Oznaczanie wapnia metodą miareczkową","methodology_en":"Determination of calcium by titration","methodology_zh":"滴定法测定钙","methodology_cs":"Stanovení vápníku titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda miareczkowa","technique_en":"titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["metoda miareczkowa"],"techniques_en":["titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wapnia metodą miareczkową\nmetoda miareczkowa","reference":"SOP č. 10 (ČSN ISO 6058)","norm_bases":["SOP č. 10","ČSN ISO 6058"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa Oznaczanie wapnia metodą miareczkową metoda miareczkowa Pitná voda, surová voda Stanovení vápníku titračně titračně SOP č. 10 (ČSN ISO 6058) Woda pitna, woda surowa Oznaczanie wapnia metoda miareczkowa metoda miareczkowa Pitna voda, surova voda Stanoveni vapniku titracne titracne SOP c. 10 (CSN ISO 6058)","search_en":"Drinking water, raw water Determination of calcium by titration titration SOP č. 10 (ČSN ISO 6058)","search_zh":"饮用水、原水 滴定法测定钙 滴定法 SOP č. 10 (ČSN ISO 6058)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0c7b0c2706fa35dd1a33fe12","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"9","test_object":"Woda pitna, woda surowa","test_object_en":"Drinking water, raw water","test_object_zh":"饮用水、原水","test_object_cs":"Pitná voda, surová voda","methodology":"Oznaczanie sumy wapnia i magnezu (Ca+Mg) metodą miareczkową","methodology_en":"Determination of the sum of calcium and magnesium (Ca+Mg) by titration","methodology_zh":"滴定法测定钙镁总量（Ca+Mg）","methodology_cs":"Stanovení sumy vápníku a hořčíku (Ca+Mg) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda miareczkowa","technique_en":"titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["metoda miareczkowa"],"techniques_en":["titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie sumy wapnia i magnezu (Ca+Mg) metodą miareczkową\nmetoda miareczkowa","reference":"SOP č. 11 (ČSN ISO 6059)","norm_bases":["SOP č. 11","ČSN ISO 6059"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa Oznaczanie sumy wapnia i magnezu (Ca+Mg) metodą miareczkową metoda miareczkowa Pitná voda, surová voda Stanovení sumy vápníku a hořčíku (Ca+Mg) titračně titračně SOP č. 11 (ČSN ISO 6059) Woda pitna, woda surowa Oznaczanie sumy wapnia i magnezu (Ca+Mg) metoda miareczkowa metoda miareczkowa Pitna voda, surova voda Stanoveni sumy vapniku a horciku (Ca+Mg) titracne titracne SOP c. 11 (CSN ISO 6059)","search_en":"Drinking water, raw water Determination of the sum of calcium and magnesium (Ca+Mg) by titration titration SOP č. 11 (ČSN ISO 6059)","search_zh":"饮用水、原水 滴定法测定钙镁总量（Ca+Mg） 滴定法 SOP č. 11 (ČSN ISO 6059)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4c06ae7f7ab8fa86e8bc982","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"10","test_object":"Woda pitna, woda surowa, ścieki","test_object_en":"Drinking water, raw water, waste water","test_object_zh":"饮用水、原水、废水","test_object_cs":"Pitná voda, surová voda, odpadní voda","methodology":"Oznaczanie chlorków metodą miareczkową","methodology_en":"Determination of chlorides by titration","methodology_zh":"滴定法测定氯化物","methodology_cs":"Stanovení chloridů titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda miareczkowa","technique_en":"titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["metoda miareczkowa"],"techniques_en":["titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków metodą miareczkową\nmetoda miareczkowa","reference":"SOP č. 12 (ČSN ISO 9297)","norm_bases":["SOP č. 12","ČSN ISO 9297"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, ścieki Oznaczanie chlorków metodą miareczkową metoda miareczkowa Pitná voda, surová voda, odpadní voda Stanovení chloridů titračně titračně SOP č. 12 (ČSN ISO 9297) Woda pitna, woda surowa, scieki Oznaczanie chlorkow metoda miareczkowa metoda miareczkowa Pitna voda, surova voda, odpadni voda Stanoveni chloridu titracne titracne SOP c. 12 (CSN ISO 9297)","search_en":"Drinking water, raw water, waste water Determination of chlorides by titration titration SOP č. 12 (ČSN ISO 9297)","search_zh":"饮用水、原水、废水 滴定法测定氯化物 滴定法 SOP č. 12 (ČSN ISO 9297)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4f7fd897b8fcd9aef953b18b","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"11","test_object":"Woda pitna, woda surowa","test_object_en":"Drinking water, raw water","test_object_zh":"饮用水、原水","test_object_cs":"Pitná voda, surová voda","methodology":"Oznaczanie żelaza metodą spektrofotometryczną","methodology_en":"Determination of iron spectrophotometrically","methodology_zh":"分光光度法测定铁","methodology_cs":"Stanovení železa spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda spektrofotometryczna","technique_en":"spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["metoda spektrofotometryczna"],"techniques_en":["spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie żelaza metodą spektrofotometryczną\nmetoda spektrofotometryczna","reference":"SOP č. 13 (ČSN ISO 6332)","norm_bases":["SOP č. 13","ČSN ISO 6332"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa Oznaczanie żelaza metodą spektrofotometryczną metoda spektrofotometryczna Pitná voda, surová voda Stanovení železa spektrofotometricky spektrofotometricky SOP č. 13 (ČSN ISO 6332) Woda pitna, woda surowa Oznaczanie zelaza metoda spektrofotometryczna metoda spektrofotometryczna Pitna voda, surova voda Stanoveni zeleza spektrofotometricky spektrofotometricky SOP c. 13 (CSN ISO 6332)","search_en":"Drinking water, raw water Determination of iron spectrophotometrically spectrophotometric method SOP č. 13 (ČSN ISO 6332)","search_zh":"饮用水、原水 分光光度法测定铁 分光光度法 SOP č. 13 (ČSN ISO 6332)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8edc8fda20b871bf74938ba0","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"12","test_object":"Woda pitna, woda surowa","test_object_en":"Drinking water, raw water","test_object_zh":"饮用水、原水","test_object_cs":"Pitná voda, surová voda","methodology":"Oznaczanie manganu metodą spektrofotometryczną","methodology_en":"Determination of manganese spectrophotometrically","methodology_zh":"分光光度法测定锰","methodology_cs":"Stanovení manganu spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda spektrofotometryczna","technique_en":"spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["metoda spektrofotometryczna"],"techniques_en":["spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie manganu metodą spektrofotometryczną\nmetoda spektrofotometryczna","reference":"SOP č. 14 (ČSN ISO 6333)","norm_bases":["SOP č. 14","ČSN ISO 6333"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa Oznaczanie manganu metodą spektrofotometryczną metoda spektrofotometryczna Pitná voda, surová voda Stanovení manganu spektrofotometricky spektrofotometricky SOP č. 14 (ČSN ISO 6333) Woda pitna, woda surowa Oznaczanie manganu metoda spektrofotometryczna metoda spektrofotometryczna Pitna voda, surova voda Stanoveni manganu spektrofotometricky spektrofotometricky SOP c. 14 (CSN ISO 6333)","search_en":"Drinking water, raw water Determination of manganese spectrophotometrically spectrophotometric method SOP č. 14 (ČSN ISO 6333)","search_zh":"饮用水、原水 分光光度法测定锰 分光光度法 SOP č. 14 (ČSN ISO 6333)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"28c82a2b8d03cf6d87baeb5d","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"13","test_object":"Woda pitna, woda surowa","test_object_en":"Drinking water, raw water","test_object_zh":"饮用水、原水","test_object_cs":"Pitná voda, surová voda","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu metodą nadmanganianową (ChZTMn) metodą miareczkową","methodology_en":"Determination of chemical oxygen demand by permanganate (CODMn) by titration","methodology_zh":"滴定法测定高锰酸盐化学需氧量（CODMn）","methodology_cs":"Stanovení chemické spotřeby kyslíku manganistanem (CHSKMn) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda miareczkowa","technique_en":"titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["metoda miareczkowa"],"techniques_en":["titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu metodą nadmanganianową (ChZTMn) metodą miareczkową\nmetoda miareczkowa","reference":"SOP č. 15 (ČSN EN ISO 8467)","norm_bases":["SOP č. 15","ČSN EN ISO 8467"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa Oznaczanie chemicznego zapotrzebowania tlenu metodą nadmanganianową (ChZTMn) metodą miareczkową metoda miareczkowa Pitná voda, surová voda Stanovení chemické spotřeby kyslíku manganistanem (CHSKMn) titračně titračně SOP č. 15 (ČSN EN ISO 8467) Woda pitna, woda surowa Oznaczanie chemicznego zapotrzebowania tlenu metoda nadmanganianowa (ChZTMn) metoda miareczkowa metoda miareczkowa Pitna voda, surova voda Stanoveni chemicke spotreby kysliku manganistanem (CHSKMn) titracne titracne SOP c. 15 (CSN EN ISO 8467)","search_en":"Drinking water, raw water Determination of chemical oxygen demand by permanganate (CODMn) by titration titration SOP č. 15 (ČSN EN ISO 8467)","search_zh":"饮用水、原水 滴定法测定高锰酸盐化学需氧量（CODMn） 滴定法 SOP č. 15 (ČSN EN ISO 8467)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3a69ce5181d9fb14a859d517","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"14","test_object":"Ścieki, woda surowa","test_object_en":"Waste water, raw water","test_object_zh":"废水、原水","test_object_cs":"Odpadní voda, surová voda","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZTCr) metodą spektrofotometryczną","methodology_en":"Determination of chemical oxygen demand by potassium dichromate (CODCr) spectrophotometrically","methodology_zh":"分光光度法测定重铬酸钾化学需氧量（CODCr）","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem draselným (CHSKCr) spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda spektrofotometryczna","technique_en":"spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["metoda spektrofotometryczna"],"techniques_en":["spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZTCr) metodą spektrofotometryczną\nmetoda spektrofotometryczna","reference":"SOP č. 16 (ČSN ISO 15705; TNV 75 7520:2002)","norm_bases":["SOP č. 16","ČSN ISO 15705","TNV 75 7520:2002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda surowa Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZTCr) metodą spektrofotometryczną metoda spektrofotometryczna Odpadní voda, surová voda Stanovení chemické spotřeby kyslíku dichromanem draselným (CHSKCr) spektrofotometricky spektrofotometricky SOP č. 16 (ČSN ISO 15705; TNV 75 7520:2002) Scieki, woda surowa Oznaczanie chemicznego zapotrzebowania tlenu dichromianem potasu (ChZTCr) metoda spektrofotometryczna metoda spektrofotometryczna Odpadni voda, surova voda Stanoveni chemicke spotreby kysliku dichromanem draselnym (CHSKCr) spektrofotometricky spektrofotometricky SOP c. 16 (CSN ISO 15705; TNV 75 7520:2002)","search_en":"Waste water, raw water Determination of chemical oxygen demand by potassium dichromate (CODCr) spectrophotometrically spectrophotometric method SOP č. 16 (ČSN ISO 15705; TNV 75 7520:2002)","search_zh":"废水、原水 分光光度法测定重铬酸钾化学需氧量（CODCr） 分光光度法 SOP č. 16 (ČSN ISO 15705; TNV 75 7520:2002)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"212909f9df7ce2506d99f165","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"15","test_object":"Woda pitna, woda surowa, ścieki, woda w kąpieliskach (baseny)","test_object_en":"Drinking water, raw water, waste water, bathing water (swimming pools)","test_object_zh":"饮用水、原水、废水、游泳用水（游泳池）","test_object_cs":"Pitná voda, surová voda, odpadní voda, voda ke koupání (bazény)","methodology":"Oznaczanie azotanów metodą spektrofotometryczną z kwasem sulfosalicylowym oraz azot azotanowy obliczeniowo z wartości zmierzonych","methodology_en":"Determination of nitrates spectrophotometrically with sulfosalicylic acid and nitrate nitrogen by calculation from measured values","methodology_zh":"磺基水杨酸分光光度法测定硝酸盐，并由测量值计算硝酸盐氮","methodology_cs":"Stanovení dusičnanů spektrofotometricky s kyselinou sulfosalicylovou a dusičnanový dusík dopočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda spektrofotometryczna z kwasem sulfosalicylowym","technique_en":"spectrophotometric method with sulfosalicylic acid","technique_zh":"磺基水杨酸分光光度法","technique_cs":"spektrofotometricky s kyselinou sulfosalicylovou","techniques":["metoda spektrofotometryczna z kwasem sulfosalicylowym"],"techniques_en":["spectrophotometric method with sulfosalicylic acid"],"techniques_zh":["磺基水杨酸分光光度法"],"techniques_cs":["spektrofotometricky s kyselinou sulfosalicylovou"],"computed":["azot azotanowy"],"computed_en":["nitrate nitrogen"],"computed_zh":["硝酸盐氮"],"computed_cs":["dusičnanový dusík"],"activity":"Oznaczanie azotanów metodą spektrofotometryczną z kwasem sulfosalicylowym oraz azot azotanowy obliczeniowo z wartości zmierzonych\nmetoda spektrofotometryczna z kwasem sulfosalicylowym","reference":"SOP č. 17 (ČSN ISO 7890–3)","norm_bases":["SOP č. 17","ČSN ISO 7890–3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, ścieki, woda w kąpieliskach (baseny) Oznaczanie azotanów metodą spektrofotometryczną z kwasem sulfosalicylowym oraz azot azotanowy obliczeniowo z wartości zmierzonych metoda spektrofotometryczna z kwasem sulfosalicylowym azot azotanowy Pitná voda, surová voda, odpadní voda, voda ke koupání (bazény) Stanovení dusičnanů spektrofotometricky s kyselinou sulfosalicylovou a dusičnanový dusík dopočtem z naměřených hodnot spektrofotometricky s kyselinou sulfosalicylovou dusičnanový dusík SOP č. 17 (ČSN ISO 7890–3) Woda pitna, woda surowa, scieki, woda w kapieliskach (baseny) Oznaczanie azotanow metoda spektrofotometryczna z kwasem sulfosalicylowym oraz azot azotanowy obliczeniowo z wartosci zmierzonych metoda spektrofotometryczna z kwasem sulfosalicylowym azot azotanowy Pitna voda, surova voda, odpadni voda, voda ke koupani (bazeny) Stanoveni dusicnanu spektrofotometricky s kyselinou sulfosalicylovou a dusicnanovy dusik dopoctem z namerenych hodnot spektrofotometricky s kyselinou sulfosalicylovou dusicnanovy dusik SOP c. 17 (CSN ISO 7890–3)","search_en":"Drinking water, raw water, waste water, bathing water (swimming pools) Determination of nitrates spectrophotometrically with sulfosalicylic acid and nitrate nitrogen by calculation from measured values spectrophotometric method with sulfosalicylic acid nitrate nitrogen SOP č. 17 (ČSN ISO 7890–3)","search_zh":"饮用水、原水、废水、游泳用水（游泳池） 磺基水杨酸分光光度法测定硝酸盐，并由测量值计算硝酸盐氮 磺基水杨酸分光光度法 硝酸盐氮 SOP č. 17 (ČSN ISO 7890–3)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ff5fe7cb4bf89ef11ee6e33a","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"16","test_object":"Woda pitna, woda surowa, ścieki","test_object_en":"Drinking water, raw water, waste water","test_object_zh":"饮用水、原水、废水","test_object_cs":"Pitná voda, surová voda, odpadní voda","methodology":"Oznaczanie azotynów metodą spektrofotometryczną oraz azot azotynowy obliczeniowo z wartości zmierzonych","methodology_en":"Determination of nitrites spectrophotometrically and nitrite nitrogen by calculation from measured values","methodology_zh":"分光光度法测定亚硝酸盐，并由测量值计算亚硝酸盐氮","methodology_cs":"Stanovení dusitanů spektrofotometricky a dusitanový dusík dopočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda spektrofotometryczna","technique_en":"spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["metoda spektrofotometryczna"],"techniques_en":["spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":["azot azotynowy"],"computed_en":["nitrite nitrogen"],"computed_zh":["亚硝酸盐氮"],"computed_cs":["dusitanový dusík"],"activity":"Oznaczanie azotynów metodą spektrofotometryczną oraz azot azotynowy obliczeniowo z wartości zmierzonych\nmetoda spektrofotometryczna","reference":"SOP č. 18 (ČSN EN 26777)","norm_bases":["SOP č. 18","ČSN EN 26777"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, ścieki Oznaczanie azotynów metodą spektrofotometryczną oraz azot azotynowy obliczeniowo z wartości zmierzonych metoda spektrofotometryczna azot azotynowy Pitná voda, surová voda, odpadní voda Stanovení dusitanů spektrofotometricky a dusitanový dusík dopočtem z naměřených hodnot spektrofotometricky dusitanový dusík SOP č. 18 (ČSN EN 26777) Woda pitna, woda surowa, scieki Oznaczanie azotynow metoda spektrofotometryczna oraz azot azotynowy obliczeniowo z wartosci zmierzonych metoda spektrofotometryczna azot azotynowy Pitna voda, surova voda, odpadni voda Stanoveni dusitanu spektrofotometricky a dusitanovy dusik dopoctem z namerenych hodnot spektrofotometricky dusitanovy dusik SOP c. 18 (CSN EN 26777)","search_en":"Drinking water, raw water, waste water Determination of nitrites spectrophotometrically and nitrite nitrogen by calculation from measured values spectrophotometric method nitrite nitrogen SOP č. 18 (ČSN EN 26777)","search_zh":"饮用水、原水、废水 分光光度法测定亚硝酸盐，并由测量值计算亚硝酸盐氮 分光光度法 亚硝酸盐氮 SOP č. 18 (ČSN EN 26777)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bedd018c0c041dea489303f5","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"17","test_object":"Woda pitna, woda surowa, ścieki","test_object_en":"Drinking water, raw water, waste water","test_object_zh":"饮用水、原水、废水","test_object_cs":"Pitná voda, surová voda, odpadní voda","methodology":"Oznaczanie jonów amonowych metodą spektrofotometryczną oraz azot amonowy obliczeniowo z wartości zmierzonych","methodology_en":"Determination of ammonium ions spectrophotometrically and ammonium nitrogen by calculation from measured values","methodology_zh":"分光光度法测定铵离子，并由测量值计算氨氮","methodology_cs":"Stanovení amonných iontů spektrofotometricky a amoniakální dusík dopočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda spektrofotometryczna","technique_en":"spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["metoda spektrofotometryczna"],"techniques_en":["spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":["azot amonowy"],"computed_en":["ammonium nitrogen"],"computed_zh":["氨氮"],"computed_cs":["amoniakální dusík"],"activity":"Oznaczanie jonów amonowych metodą spektrofotometryczną oraz azot amonowy obliczeniowo z wartości zmierzonych\nmetoda spektrofotometryczna","reference":"SOP č. 19 (ČSN ISO 7150–1)","norm_bases":["SOP č. 19","ČSN ISO 7150–1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, ścieki Oznaczanie jonów amonowych metodą spektrofotometryczną oraz azot amonowy obliczeniowo z wartości zmierzonych metoda spektrofotometryczna azot amonowy Pitná voda, surová voda, odpadní voda Stanovení amonných iontů spektrofotometricky a amoniakální dusík dopočtem z naměřených hodnot spektrofotometricky amoniakální dusík SOP č. 19 (ČSN ISO 7150–1) Woda pitna, woda surowa, scieki Oznaczanie jonow amonowych metoda spektrofotometryczna oraz azot amonowy obliczeniowo z wartosci zmierzonych metoda spektrofotometryczna azot amonowy Pitna voda, surova voda, odpadni voda Stanoveni amonnych iontu spektrofotometricky a amoniakalni dusik dopoctem z namerenych hodnot spektrofotometricky amoniakalni dusik SOP c. 19 (CSN ISO 7150–1)","search_en":"Drinking water, raw water, waste water Determination of ammonium ions spectrophotometrically and ammonium nitrogen by calculation from measured values spectrophotometric method ammonium nitrogen SOP č. 19 (ČSN ISO 7150–1)","search_zh":"饮用水、原水、废水 分光光度法测定铵离子，并由测量值计算氨氮 分光光度法 氨氮 SOP č. 19 (ČSN ISO 7150–1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d61e48dc53680f96dea624a2","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"18","test_object":"Woda surowa, ścieki","test_object_en":"Raw water, waste water","test_object_zh":"原水、废水","test_object_cs":"Surová voda, odpadní voda","methodology":"Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach (BZTn) metodą elektrochemiczną z sondą membranową","methodology_en":"Determination of biochemical oxygen demand after n days (BODn) by electrochemical method with membrane probe","methodology_zh":"膜电极电化学法测定n天生化需氧量（BODn）","methodology_cs":"Stanovení biochemické spotřeby kyslíku po n dnech (BSKn) elektrochemickou metodou s membránovou sondou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda elektrochemiczna z sondą membranową","technique_en":"electrochemical method with membrane probe","technique_zh":"膜电极电化学法","technique_cs":"elektrochemickou metodou s membránovou sondou","techniques":["metoda elektrochemiczna z sondą membranową"],"techniques_en":["electrochemical method with membrane probe"],"techniques_zh":["膜电极电化学法"],"techniques_cs":["elektrochemickou metodou s membránovou sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach (BZTn) metodą elektrochemiczną z sondą membranową\nmetoda elektrochemiczna z sondą membranową","reference":"SOP č. 21-1, Příloha C (ČSN EN ISO 5815–1); SOP č. 26 (ČSN EN 1899–2)","norm_bases":["SOP č. 21-1, Příloha C","ČSN EN ISO 5815–1","SOP č. 26","ČSN EN 1899–2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda surowa, ścieki Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach (BZTn) metodą elektrochemiczną z sondą membranową metoda elektrochemiczna z sondą membranową Surová voda, odpadní voda Stanovení biochemické spotřeby kyslíku po n dnech (BSKn) elektrochemickou metodou s membránovou sondou elektrochemickou metodou s membránovou sondou SOP č. 21-1, Příloha C (ČSN EN ISO 5815–1); SOP č. 26 (ČSN EN 1899–2) Woda surowa, scieki Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach (BZTn) metoda elektrochemiczna z sonda membranowa metoda elektrochemiczna z sonda membranowa Surova voda, odpadni voda Stanoveni biochemicke spotreby kysliku po n dnech (BSKn) elektrochemickou metodou s membranovou sondou elektrochemickou metodou s membranovou sondou SOP c. 21-1, Priloha C (CSN EN ISO 5815–1); SOP c. 26 (CSN EN 1899–2)","search_en":"Raw water, waste water Determination of biochemical oxygen demand after n days (BODn) by electrochemical method with membrane probe electrochemical method with membrane probe SOP č. 21-1, Příloha C (ČSN EN ISO 5815–1); SOP č. 26 (ČSN EN 1899–2)","search_zh":"原水、废水 膜电极电化学法测定n天生化需氧量（BODn） 膜电极电化学法 SOP č. 21-1, Příloha C (ČSN EN ISO 5815–1); SOP č. 26 (ČSN EN 1899–2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6bf624b77c9b798b1fbe66aa","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"19","test_object":"Ścieki, woda surowa","test_object_en":"Waste water, raw water","test_object_zh":"废水、原水","test_object_cs":"Odpadní voda, surová voda","methodology":"Oznaczanie zawiesin suszonych w 105 °C metodą grawimetryczną","methodology_en":"Determination of suspended solids dried at 105 °C by gravimetry","methodology_zh":"重量法测定105 °C烘干的悬浮物","methodology_cs":"Stanovení nerozpuštěných látek sušených při 105 °C gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda grawimetryczna","technique_en":"gravimetric method","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda grawimetryczna"],"techniques_en":["gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesin suszonych w 105 °C metodą grawimetryczną\nmetoda grawimetryczna","reference":"SOP č. 22 (ČSN EN 872)","norm_bases":["SOP č. 22","ČSN EN 872"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, woda surowa Oznaczanie zawiesin suszonych w 105 °C metodą grawimetryczną metoda grawimetryczna Odpadní voda, surová voda Stanovení nerozpuštěných látek sušených při 105 °C gravimetricky gravimetricky SOP č. 22 (ČSN EN 872) Scieki, woda surowa Oznaczanie zawiesin suszonych w 105 °C metoda grawimetryczna metoda grawimetryczna Odpadni voda, surova voda Stanoveni nerozpustenych latek susenych pri 105 °C gravimetricky gravimetricky SOP c. 22 (CSN EN 872)","search_en":"Waste water, raw water Determination of suspended solids dried at 105 °C by gravimetry gravimetric method SOP č. 22 (ČSN EN 872)","search_zh":"废水、原水 重量法测定105 °C烘干的悬浮物 重量法 SOP č. 22 (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"72d81e8980bc67e86cc239cf","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"20","test_object":"Woda pitna, woda surowa, ścieki","test_object_en":"Drinking water, raw water, waste water","test_object_zh":"饮用水、原水、废水","test_object_cs":"Pitná voda, surová voda, odpadní voda","methodology":"Oznaczanie substancji rozpuszczonych suszonych w 105 °C i prażonych w 550 °C metodą grawimetryczną","methodology_en":"Determination of dissolved solids dried at 105 °C and ignited at 550 °C by gravimetry","methodology_zh":"重量法测定105 °C烘干和550 °C灼烧的溶解性物质","methodology_cs":"Stanovení rozpuštěných látek sušených při 105 °C a žíhaných při 550 °C gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda grawimetryczna","technique_en":"gravimetric method","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda grawimetryczna"],"techniques_en":["gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych suszonych w 105 °C i prażonych w 550 °C metodą grawimetryczną\nmetoda grawimetryczna","reference":"SOP č. 23 (ČSN 75 7346; ČSN 75 7347)","norm_bases":["SOP č. 23","ČSN 75 7346","ČSN 75 7347"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, ścieki Oznaczanie substancji rozpuszczonych suszonych w 105 °C i prażonych w 550 °C metodą grawimetryczną metoda grawimetryczna Pitná voda, surová voda, odpadní voda Stanovení rozpuštěných látek sušených při 105 °C a žíhaných při 550 °C gravimetricky gravimetricky SOP č. 23 (ČSN 75 7346; ČSN 75 7347) Woda pitna, woda surowa, scieki Oznaczanie substancji rozpuszczonych suszonych w 105 °C i prazonych w 550 °C metoda grawimetryczna metoda grawimetryczna Pitna voda, surova voda, odpadni voda Stanoveni rozpustenych latek susenych pri 105 °C a zihanych pri 550 °C gravimetricky gravimetricky SOP c. 23 (CSN 75 7346; CSN 75 7347)","search_en":"Drinking water, raw water, waste water Determination of dissolved solids dried at 105 °C and ignited at 550 °C by gravimetry gravimetric method SOP č. 23 (ČSN 75 7346; ČSN 75 7347)","search_zh":"饮用水、原水、废水 重量法测定105 °C烘干和550 °C灼烧的溶解性物质 重量法 SOP č. 23 (ČSN 75 7346; ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0ae939a8c70652b349ebb257","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"21","test_object":"Woda pitna, woda surowa, ścieki","test_object_en":"Drinking water, raw water, waste water","test_object_zh":"饮用水、原水、废水","test_object_cs":"Pitná voda, surová voda, odpadní voda","methodology":"Oznaczanie zdolności neutralizacji kwasów (zasadowości KNK4,5 i KNK8,3) metodą miareczkową","methodology_en":"Determination of acid neutralising capacity (KNK4.5 and KNK8.3) by titration","methodology_zh":"滴定法测定酸中和能力（KNK4.5和KNK8.3）","methodology_cs":"Stanovení kyselinové neutralizační kapacity (KNK4,5 a KNK8,3) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda miareczkowa","technique_en":"titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["metoda miareczkowa"],"techniques_en":["titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zdolności neutralizacji kwasów (zasadowości KNK4,5 i KNK8,3) metodą miareczkową\nmetoda miareczkowa","reference":"SOP č. 24 (ČSN EN ISO 9963–1)","norm_bases":["SOP č. 24","ČSN EN ISO 9963–1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, ścieki Oznaczanie zdolności neutralizacji kwasów (zasadowości KNK4,5 i KNK8,3) metodą miareczkową metoda miareczkowa Pitná voda, surová voda, odpadní voda Stanovení kyselinové neutralizační kapacity (KNK4,5 a KNK8,3) titračně titračně SOP č. 24 (ČSN EN ISO 9963–1) Woda pitna, woda surowa, scieki Oznaczanie zdolnosci neutralizacji kwasow (zasadowosci KNK4,5 i KNK8,3) metoda miareczkowa metoda miareczkowa Pitna voda, surova voda, odpadni voda Stanoveni kyselinove neutralizacni kapacity (KNK4,5 a KNK8,3) titracne titracne SOP c. 24 (CSN EN ISO 9963–1)","search_en":"Drinking water, raw water, waste water Determination of acid neutralising capacity (KNK4.5 and KNK8.3) by titration titration SOP č. 24 (ČSN EN ISO 9963–1)","search_zh":"饮用水、原水、废水 滴定法测定酸中和能力（KNK4.5和KNK8.3） 滴定法 SOP č. 24 (ČSN EN ISO 9963–1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0b8c4363d98206bbe56bc219","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"22","test_object":"Woda pitna, woda surowa, ścieki","test_object_en":"Drinking water, raw water, waste water","test_object_zh":"饮用水、原水、废水","test_object_cs":"Pitná voda, surová voda, odpadní voda","methodology":"Oznaczanie przewodności właściwej metodą konduktometryczną","methodology_en":"Determination of conductivity by conductometry","methodology_zh":"电导法测定电导率","methodology_cs":"Stanovení konduktivity konduktometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda konduktometryczna","technique_en":"conductometric method","technique_zh":"电导法","technique_cs":"konduktometricky","techniques":["metoda konduktometryczna"],"techniques_en":["conductometric method"],"techniques_zh":["电导法"],"techniques_cs":["konduktometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności właściwej metodą konduktometryczną\nmetoda konduktometryczna","reference":"SOP č. 25 (ČSN EN 27888)","norm_bases":["SOP č. 25","ČSN EN 27888"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, ścieki Oznaczanie przewodności właściwej metodą konduktometryczną metoda konduktometryczna Pitná voda, surová voda, odpadní voda Stanovení konduktivity konduktometricky konduktometricky SOP č. 25 (ČSN EN 27888) Woda pitna, woda surowa, scieki Oznaczanie przewodnosci wlasciwej metoda konduktometryczna metoda konduktometryczna Pitna voda, surova voda, odpadni voda Stanoveni konduktivity konduktometricky konduktometricky SOP c. 25 (CSN EN 27888)","search_en":"Drinking water, raw water, waste water Determination of conductivity by conductometry conductometric method SOP č. 25 (ČSN EN 27888)","search_zh":"饮用水、原水、废水 电导法测定电导率 电导法 SOP č. 25 (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a02480fcf6815c489b8c7070","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"23","test_object":"Woda surowa, ścieki","test_object_en":"Raw water, waste water","test_object_zh":"原水、废水","test_object_cs":"Surová voda, odpadní voda","methodology":"Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach (BZTn) metodą elektrochemiczną z sondą optyczną","methodology_en":"Determination of biochemical oxygen demand after n days (BODn) by electrochemical method with optical probe","methodology_zh":"光学探头电化学法测定n天生化需氧量（BODn）","methodology_cs":"Stanovení biochemické spotřeby kyslíku po n dnech (BSKn) elektrochemickou metodou s optickou sondou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda elektrochemiczna z sondą optyczną","technique_en":"electrochemical method with optical probe","technique_zh":"光学探头电化学法","technique_cs":"elektrochemickou metodou s optickou sondou","techniques":["metoda elektrochemiczna z sondą optyczną"],"techniques_en":["electrochemical method with optical probe"],"techniques_zh":["光学探头电化学法"],"techniques_cs":["elektrochemickou metodou s optickou sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach (BZTn) metodą elektrochemiczną z sondą optyczną\nmetoda elektrochemiczna z sondą optyczną","reference":"SOP č. 21-1 Příloha D (ČSN EN ISO 5815–1); SOP č. 26 (ČSN EN 1899–2)","norm_bases":["SOP č. 21-1 Příloha D","ČSN EN ISO 5815–1","SOP č. 26","ČSN EN 1899–2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda surowa, ścieki Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach (BZTn) metodą elektrochemiczną z sondą optyczną metoda elektrochemiczna z sondą optyczną Surová voda, odpadní voda Stanovení biochemické spotřeby kyslíku po n dnech (BSKn) elektrochemickou metodou s optickou sondou elektrochemickou metodou s optickou sondou SOP č. 21-1 Příloha D (ČSN EN ISO 5815–1); SOP č. 26 (ČSN EN 1899–2) Woda surowa, scieki Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach (BZTn) metoda elektrochemiczna z sonda optyczna metoda elektrochemiczna z sonda optyczna Surova voda, odpadni voda Stanoveni biochemicke spotreby kysliku po n dnech (BSKn) elektrochemickou metodou s optickou sondou elektrochemickou metodou s optickou sondou SOP c. 21-1 Priloha D (CSN EN ISO 5815–1); SOP c. 26 (CSN EN 1899–2)","search_en":"Raw water, waste water Determination of biochemical oxygen demand after n days (BODn) by electrochemical method with optical probe electrochemical method with optical probe SOP č. 21-1 Příloha D (ČSN EN ISO 5815–1); SOP č. 26 (ČSN EN 1899–2)","search_zh":"原水、废水 光学探头电化学法测定n天生化需氧量（BODn） 光学探头电化学法 SOP č. 21-1 Příloha D (ČSN EN ISO 5815–1); SOP č. 26 (ČSN EN 1899–2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fbfce1bed4c06bb5ec06c62a","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"24","test_object":"Woda pitna, woda surowa","test_object_en":"Drinking water, raw water","test_object_zh":"饮用水、原水","test_object_cs":"Pitná voda, surová voda","methodology":"Oznaczanie sumy wapnia i magnezu (Ca+Mg) metodą miareczkowania kompleksometrycznego oraz magnez (Mg) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of the sum of calcium and magnesium (Ca+Mg) by complexometric titration and magnesium (Mg) by calculation from measured values","methodology_zh":"络合滴定法测定钙镁总量（Ca+Mg），并由测量值计算镁（Mg）","methodology_cs":"Stanovení sumy vápníku a hořčíku (Ca+Mg) komplexometrickou titrací a hořčík (Mg) dopočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"miareczkowanie kompleksometryczne","technique_en":"complexometric titration","technique_zh":"络合滴定法","technique_cs":"komplexometrickou titrací","techniques":["miareczkowanie kompleksometryczne"],"techniques_en":["complexometric titration"],"techniques_zh":["络合滴定法"],"techniques_cs":["komplexometrickou titrací"],"computed":["magnez (Mg)"],"computed_en":["magnesium (Mg)"],"computed_zh":["镁（Mg）"],"computed_cs":["hořčík (Mg)"],"activity":"Oznaczanie sumy wapnia i magnezu (Ca+Mg) metodą miareczkowania kompleksometrycznego oraz magnez (Mg) obliczeniowo z wartości zmierzonych\nmiareczkowanie kompleksometryczne","reference":"SOP č. 27 (ČSN ISO 6058; ČSN ISO 6059)","norm_bases":["SOP č. 27","ČSN ISO 6058","ČSN ISO 6059"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa Oznaczanie sumy wapnia i magnezu (Ca+Mg) metodą miareczkowania kompleksometrycznego oraz magnez (Mg) obliczeniowo z wartości zmierzonych miareczkowanie kompleksometryczne magnez (Mg) Pitná voda, surová voda Stanovení sumy vápníku a hořčíku (Ca+Mg) komplexometrickou titrací a hořčík (Mg) dopočtem z naměřených hodnot komplexometrickou titrací hořčík (Mg) SOP č. 27 (ČSN ISO 6058; ČSN ISO 6059) Woda pitna, woda surowa Oznaczanie sumy wapnia i magnezu (Ca+Mg) metoda miareczkowania kompleksometrycznego oraz magnez (Mg) obliczeniowo z wartosci zmierzonych miareczkowanie kompleksometryczne magnez (Mg) Pitna voda, surova voda Stanoveni sumy vapniku a horciku (Ca+Mg) komplexometrickou titraci a horcik (Mg) dopoctem z namerenych hodnot komplexometrickou titraci horcik (Mg) SOP c. 27 (CSN ISO 6058; CSN ISO 6059)","search_en":"Drinking water, raw water Determination of the sum of calcium and magnesium (Ca+Mg) by complexometric titration and magnesium (Mg) by calculation from measured values complexometric titration magnesium (Mg) SOP č. 27 (ČSN ISO 6058; ČSN ISO 6059)","search_zh":"饮用水、原水 络合滴定法测定钙镁总量（Ca+Mg），并由测量值计算镁（Mg） 络合滴定法 镁（Mg） SOP č. 27 (ČSN ISO 6058; ČSN ISO 6059)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2d57e46210d76ffc1be8b69a","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"25","test_object":"Woda pitna, woda surowa, ścieki","test_object_en":"Drinking water, raw water, waste water","test_object_zh":"饮用水、原水、废水","test_object_cs":"Pitná voda, surová voda, odpadní voda","methodology":"Oznaczanie fosforu ogólnego metodą spektrofotometryczną","methodology_en":"Determination of total phosphorus spectrophotometrically","methodology_zh":"分光光度法测定总磷","methodology_cs":"Stanovení celkového fosforu spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda spektrofotometryczna","technique_en":"spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["metoda spektrofotometryczna"],"techniques_en":["spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforu ogólnego metodą spektrofotometryczną\nmetoda spektrofotometryczna","reference":"SOP č. 28 (ČSN EN ISO 6878)","norm_bases":["SOP č. 28","ČSN EN ISO 6878"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, ścieki Oznaczanie fosforu ogólnego metodą spektrofotometryczną metoda spektrofotometryczna Pitná voda, surová voda, odpadní voda Stanovení celkového fosforu spektrofotometricky spektrofotometricky SOP č. 28 (ČSN EN ISO 6878) Woda pitna, woda surowa, scieki Oznaczanie fosforu ogolnego metoda spektrofotometryczna metoda spektrofotometryczna Pitna voda, surova voda, odpadni voda Stanoveni celkoveho fosforu spektrofotometricky spektrofotometricky SOP c. 28 (CSN EN ISO 6878)","search_en":"Drinking water, raw water, waste water Determination of total phosphorus spectrophotometrically spectrophotometric method SOP č. 28 (ČSN EN ISO 6878)","search_zh":"饮用水、原水、废水 分光光度法测定总磷 分光光度法 SOP č. 28 (ČSN EN ISO 6878)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4a4e2b1394a0c6ea4dd5c1c6","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"26","test_object":"Woda pitna, woda surowa","test_object_en":"Drinking water, raw water","test_object_zh":"饮用水、原水","test_object_cs":"Pitná voda, surová voda","methodology":"Oznaczanie siarczanów metodą turbidymetryczną","methodology_en":"Determination of sulphates by turbidimetry","methodology_zh":"比浊法测定硫酸盐","methodology_cs":"Stanovení síranů turbidimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda turbidymetryczna","technique_en":"turbidimetric method","technique_zh":"比浊法","technique_cs":"turbidimetricky","techniques":["metoda turbidymetryczna"],"techniques_en":["turbidimetric method"],"techniques_zh":["比浊法"],"techniques_cs":["turbidimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie siarczanów metodą turbidymetryczną\nmetoda turbidymetryczna","reference":"SOP č. 30 (EPA 375.4)","norm_bases":["SOP č. 30","EPA 375.4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa Oznaczanie siarczanów metodą turbidymetryczną metoda turbidymetryczna Pitná voda, surová voda Stanovení síranů turbidimetricky turbidimetricky SOP č. 30 (EPA 375.4) Woda pitna, woda surowa Oznaczanie siarczanow metoda turbidymetryczna metoda turbidymetryczna Pitna voda, surova voda Stanoveni siranu turbidimetricky turbidimetricky SOP c. 30 (EPA 375.4)","search_en":"Drinking water, raw water Determination of sulphates by turbidimetry turbidimetric method SOP č. 30 (EPA 375.4)","search_zh":"饮用水、原水 比浊法测定硫酸盐 比浊法 SOP č. 30 (EPA 375.4)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"57ccbb5ec0f5dd172e12b557","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"27","test_object":"Woda pitna, woda surowa, ścieki","test_object_en":"Drinking water, raw water, waste water","test_object_zh":"饮用水、原水、废水","test_object_cs":"Pitná voda, surová voda, odpadní voda","methodology":"Oznaczanie glinu metodą spektrofotometryczną","methodology_en":"Determination of aluminium spectrophotometrically","methodology_zh":"分光光度法测定铝","methodology_cs":"Stanovení hliníku spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda spektrofotometryczna","technique_en":"spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["metoda spektrofotometryczna"],"techniques_en":["spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie glinu metodą spektrofotometryczną\nmetoda spektrofotometryczna","reference":"SOP č. 33 (ČSN ISO 10566)","norm_bases":["SOP č. 33","ČSN ISO 10566"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, ścieki Oznaczanie glinu metodą spektrofotometryczną metoda spektrofotometryczna Pitná voda, surová voda, odpadní voda Stanovení hliníku spektrofotometricky spektrofotometricky SOP č. 33 (ČSN ISO 10566) Woda pitna, woda surowa, scieki Oznaczanie glinu metoda spektrofotometryczna metoda spektrofotometryczna Pitna voda, surova voda, odpadni voda Stanoveni hliniku spektrofotometricky spektrofotometricky SOP c. 33 (CSN ISO 10566)","search_en":"Drinking water, raw water, waste water Determination of aluminium spectrophotometrically spectrophotometric method SOP č. 33 (ČSN ISO 10566)","search_zh":"饮用水、原水、废水 分光光度法测定铝 分光光度法 SOP č. 33 (ČSN ISO 10566)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7c31c3294fad96a6388b2d22","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"28","test_object":"Woda pitna, woda surowa","test_object_en":"Drinking water, raw water","test_object_zh":"饮用水、原水","test_object_cs":"Pitná voda, surová voda","methodology":"Oznaczanie ortofosforanów metodą spektrofotometryczną","methodology_en":"Determination of orthophosphates spectrophotometrically","methodology_zh":"分光光度法测定正磷酸盐","methodology_cs":"Stanovení ortofosforečnanů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda spektrofotometryczna","technique_en":"spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["metoda spektrofotometryczna"],"techniques_en":["spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ortofosforanów metodą spektrofotometryczną\nmetoda spektrofotometryczna","reference":"SOP č. 34 (ČSN EN ISO 6878)","norm_bases":["SOP č. 34","ČSN EN ISO 6878"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa Oznaczanie ortofosforanów metodą spektrofotometryczną metoda spektrofotometryczna Pitná voda, surová voda Stanovení ortofosforečnanů spektrofotometricky spektrofotometricky SOP č. 34 (ČSN EN ISO 6878) Woda pitna, woda surowa Oznaczanie ortofosforanow metoda spektrofotometryczna metoda spektrofotometryczna Pitna voda, surova voda Stanoveni ortofosforecnanu spektrofotometricky spektrofotometricky SOP c. 34 (CSN EN ISO 6878)","search_en":"Drinking water, raw water Determination of orthophosphates spectrophotometrically spectrophotometric method SOP č. 34 (ČSN EN ISO 6878)","search_zh":"饮用水、原水 分光光度法测定正磷酸盐 分光光度法 SOP č. 34 (ČSN EN ISO 6878)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"be75ba94d2e55d1d30b77424","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"29","test_object":"Woda pitna, woda surowa, ścieki, woda w kąpieliskach (baseny)","test_object_en":"Drinking water, raw water, waste water, bathing water (swimming pools)","test_object_zh":"饮用水、原水、废水、游泳用水（游泳池）","test_object_cs":"Pitná voda, surová voda, odpadní voda, voda ke koupání (bazény)","methodology":"Oznaczanie temperatury wody","methodology_en":"Determination of water temperature","methodology_zh":"水温的测定","methodology_cs":"Stanovení teploty vody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury wody","reference":"SOP č. 35 (ČSN 75 7342)","norm_bases":["SOP č. 35","ČSN 75 7342"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, ścieki, woda w kąpieliskach (baseny) Oznaczanie temperatury wody Pitná voda, surová voda, odpadní voda, voda ke koupání (bazény) Stanovení teploty vody SOP č. 35 (ČSN 75 7342) Woda pitna, woda surowa, scieki, woda w kapieliskach (baseny) Oznaczanie temperatury wody Pitna voda, surova voda, odpadni voda, voda ke koupani (bazeny) Stanoveni teploty vody SOP c. 35 (CSN 75 7342)","search_en":"Drinking water, raw water, waste water, bathing water (swimming pools) Determination of water temperature SOP č. 35 (ČSN 75 7342)","search_zh":"饮用水、原水、废水、游泳用水（游泳池） 水温的测定 SOP č. 35 (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8563478781cb946a27a69184","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"30","test_object":"Woda surowa, ścieki","test_object_en":"Raw water, waste water","test_object_zh":"原水、废水","test_object_cs":"Surová voda, odpadní voda","methodology":"Oznaczanie tlenu rozpuszczonego metodą elektrochemiczną z sondą membranową","methodology_en":"Determination of dissolved oxygen by electrochemical method with membrane probe","methodology_zh":"膜电极电化学法测定溶解氧","methodology_cs":"Stanovení rozpuštěného kyslíku elektrochemickou metodou s membránovou sondou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda elektrochemiczna z sondą membranową","technique_en":"electrochemical method with membrane probe","technique_zh":"膜电极电化学法","technique_cs":"elektrochemickou metodou s membránovou sondou","techniques":["metoda elektrochemiczna z sondą membranową"],"techniques_en":["electrochemical method with membrane probe"],"techniques_zh":["膜电极电化学法"],"techniques_cs":["elektrochemickou metodou s membránovou sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tlenu rozpuszczonego metodą elektrochemiczną z sondą membranową\nmetoda elektrochemiczna z sondą membranową","reference":"SOP č. 36 (ČSN EN ISO 5814)","norm_bases":["SOP č. 36","ČSN EN ISO 5814"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda surowa, ścieki Oznaczanie tlenu rozpuszczonego metodą elektrochemiczną z sondą membranową metoda elektrochemiczna z sondą membranową Surová voda, odpadní voda Stanovení rozpuštěného kyslíku elektrochemickou metodou s membránovou sondou elektrochemickou metodou s membránovou sondou SOP č. 36 (ČSN EN ISO 5814) Woda surowa, scieki Oznaczanie tlenu rozpuszczonego metoda elektrochemiczna z sonda membranowa metoda elektrochemiczna z sonda membranowa Surova voda, odpadni voda Stanoveni rozpusteneho kysliku elektrochemickou metodou s membranovou sondou elektrochemickou metodou s membranovou sondou SOP c. 36 (CSN EN ISO 5814)","search_en":"Raw water, waste water Determination of dissolved oxygen by electrochemical method with membrane probe electrochemical method with membrane probe SOP č. 36 (ČSN EN ISO 5814)","search_zh":"原水、废水 膜电极电化学法测定溶解氧 膜电极电化学法 SOP č. 36 (ČSN EN ISO 5814)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"92eea72574b5a03d7a09e728","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"31","test_object":"Woda pitna, woda w kąpieliskach (baseny)","test_object_en":"Drinking water, bathing water (swimming pools)","test_object_zh":"饮用水、游泳用水（游泳池）","test_object_cs":"Pitná voda, voda ke koupání (bazény)","methodology":"Oznaczanie chloru wolnego i całkowitego (zestaw Hach) oraz chloru związanego obliczeniowo z wartości zmierzonych","methodology_en":"Determination of free and total chlorine (Hach kit) and of combined chlorine by calculation from measured values","methodology_zh":"测定游离氯和总氯（Hach试剂盒），并由测量值计算结合氯","methodology_cs":"Stanovení volného a celkového chloru (set Hach) a vázaného chloru dopočtem z naměřených hodnot","parameters":[{"name":"chlor wolny","range":""},{"name":"chlor całkowity","range":""}],"parameters_en":[{"name":"free chlorine","range":""},{"name":"total chlorine","range":""}],"parameters_zh":[{"name":"游离氯","range":""},{"name":"总氯","range":""}],"parameters_cs":[{"name":"volného chloru","range":""},{"name":"celkového chloru","range":""}],"technique":"zestaw Hach","technique_en":"Hach kit","technique_zh":"Hach试剂盒","technique_cs":"set Hach","techniques":["zestaw Hach"],"techniques_en":["Hach kit"],"techniques_zh":["Hach试剂盒"],"techniques_cs":["set Hach"],"computed":["chlor związany"],"computed_en":["combined chlorine"],"computed_zh":["结合氯"],"computed_cs":["vázaného chloru"],"activity":"Oznaczanie chloru wolnego i całkowitego (zestaw Hach) oraz chloru związanego obliczeniowo z wartości zmierzonych\nZakres:\nchlor wolny\nchlor całkowity\nzestaw Hach","reference":"SOP č. 42 (ČSN EN ISO 7393-2; návod firmy Hach)","norm_bases":["SOP č. 42","ČSN EN ISO 7393-2","návod firmy Hach"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda w kąpieliskach (baseny) Oznaczanie chloru wolnego i całkowitego (zestaw Hach) oraz chloru związanego obliczeniowo z wartości zmierzonych zestaw Hach chlor wolny  chlor całkowity  chlor związany Pitná voda, voda ke koupání (bazény) Stanovení volného a celkového chloru (set Hach) a vázaného chloru dopočtem z naměřených hodnot set Hach volného chloru  celkového chloru  vázaného chloru SOP č. 42 (ČSN EN ISO 7393-2; návod firmy Hach) Woda pitna, woda w kapieliskach (baseny) Oznaczanie chloru wolnego i calkowitego (zestaw Hach) oraz chloru zwiazanego obliczeniowo z wartosci zmierzonych zestaw Hach chlor wolny  chlor calkowity  chlor zwiazany Pitna voda, voda ke koupani (bazeny) Stanoveni volneho a celkoveho chloru (set Hach) a vazaneho chloru dopoctem z namerenych hodnot set Hach volneho chloru  celkoveho chloru  vazaneho chloru SOP c. 42 (CSN EN ISO 7393-2; navod firmy Hach)","search_en":"Drinking water, bathing water (swimming pools) Determination of free and total chlorine (Hach kit) and of combined chlorine by calculation from measured values Hach kit free chlorine  total chlorine  combined chlorine SOP č. 42 (ČSN EN ISO 7393-2; návod firmy Hach)","search_zh":"饮用水、游泳用水（游泳池） 测定游离氯和总氯（Hach试剂盒），并由测量值计算结合氯 Hach试剂盒 游离氯  总氯  结合氯 SOP č. 42 (ČSN EN ISO 7393-2; návod firmy Hach)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cb580c54069f7f4a522dbd85","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"32","test_object":"Woda pitna, woda surowa, woda w kąpieliskach (baseny)","test_object_en":"Drinking water, raw water, bathing water (swimming pools)","test_object_zh":"饮用水、原水、游泳用水（游泳池）","test_object_cs":"Pitná voda, surová voda, voda ke koupání (bazény)","methodology":"Oznaczanie azotanów metodą spektrofotometryczną w zakresie UV","methodology_en":"Determination of nitrates spectrophotometrically in the UV region","methodology_zh":"紫外区分光光度法测定硝酸盐","methodology_cs":"Stanovení dusičnanů spektrofotometricky v UV oblasti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"spektrofotometria w zakresie UV","technique_en":"UV spectrophotometry","technique_zh":"紫外分光光度法","technique_cs":"spektrofotometricky v UV oblasti","techniques":["spektrofotometria w zakresie UV"],"techniques_en":["UV spectrophotometry"],"techniques_zh":["紫外分光光度法"],"techniques_cs":["spektrofotometricky v UV oblasti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotanów metodą spektrofotometryczną w zakresie UV\nspektrofotometria w zakresie UV","reference":"SOP č. 39 (Janoušek I., Fiala J.: Vodní hospodářství, 2, 1988, 51)","norm_bases":["SOP č. 39","Janoušek I., Fiala J.: Vodní hospodářství, 2, 1988, 51"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa, woda w kąpieliskach (baseny) Oznaczanie azotanów metodą spektrofotometryczną w zakresie UV spektrofotometria w zakresie UV Pitná voda, surová voda, voda ke koupání (bazény) Stanovení dusičnanů spektrofotometricky v UV oblasti spektrofotometricky v UV oblasti SOP č. 39 (Janoušek I., Fiala J.: Vodní hospodářství, 2, 1988, 51) Woda pitna, woda surowa, woda w kapieliskach (baseny) Oznaczanie azotanow metoda spektrofotometryczna w zakresie UV spektrofotometria w zakresie UV Pitna voda, surova voda, voda ke koupani (bazeny) Stanoveni dusicnanu spektrofotometricky v UV oblasti spektrofotometricky v UV oblasti SOP c. 39 (Janousek I., Fiala J.: Vodni hospodarstvi, 2, 1988, 51)","search_en":"Drinking water, raw water, bathing water (swimming pools) Determination of nitrates spectrophotometrically in the UV region UV spectrophotometry SOP č. 39 (Janoušek I., Fiala J.: Vodní hospodářství, 2, 1988, 51)","search_zh":"饮用水、原水、游泳用水（游泳池） 紫外区分光光度法测定硝酸盐 紫外分光光度法 SOP č. 39 (Janoušek I., Fiala J.: Vodní hospodářství, 2, 1988, 51)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5a0dff91e83db8a543db77d9","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"33","test_object":"Woda pitna","test_object_en":"Drinking water","test_object_zh":"饮用水","test_object_cs":"Pitná voda","methodology":"Oznaczanie barwy metodą spektrofotometryczną","methodology_en":"Determination of colour spectrophotometrically","methodology_zh":"分光光度法测定色度","methodology_cs":"Stanovení barvy spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda spektrofotometryczna","technique_en":"spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["metoda spektrofotometryczna"],"techniques_en":["spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie barwy metodą spektrofotometryczną\nmetoda spektrofotometryczna","reference":"SOP č. 40 (ČSN EN ISO 7887 Metoda B)","norm_bases":["SOP č. 40","ČSN EN ISO 7887 Metoda B"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna Oznaczanie barwy metodą spektrofotometryczną metoda spektrofotometryczna Pitná voda Stanovení barvy spektrofotometricky spektrofotometricky SOP č. 40 (ČSN EN ISO 7887 Metoda B) Woda pitna Oznaczanie barwy metoda spektrofotometryczna metoda spektrofotometryczna Pitna voda Stanoveni barvy spektrofotometricky spektrofotometricky SOP c. 40 (CSN EN ISO 7887 Metoda B)","search_en":"Drinking water Determination of colour spectrophotometrically spectrophotometric method SOP č. 40 (ČSN EN ISO 7887 Metoda B)","search_zh":"饮用水 分光光度法测定色度 分光光度法 SOP č. 40 (ČSN EN ISO 7887 Metoda B)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3e1edcf4d80912a00dce0ea7","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"34","test_object":"Woda w kąpieliskach (baseny)","test_object_en":"Bathing water (swimming pools)","test_object_zh":"游泳用水（游泳池）","test_object_cs":"Voda ke koupání (bazény)","methodology":"Oznaczanie potencjału oksydacyjno-redukcyjnego","methodology_en":"Determination of oxidation-reduction potential","methodology_zh":"氧化还原电位的测定","methodology_cs":"Stanovení oxidačně redukčního potenciálu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie potencjału oksydacyjno-redukcyjnego","reference":"SOP č. 107 (ČSN 75 7367)","norm_bases":["SOP č. 107","ČSN 75 7367"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda w kąpieliskach (baseny) Oznaczanie potencjału oksydacyjno-redukcyjnego Voda ke koupání (bazény) Stanovení oxidačně redukčního potenciálu SOP č. 107 (ČSN 75 7367) Woda w kapieliskach (baseny) Oznaczanie potencjalu oksydacyjno-redukcyjnego Voda ke koupani (bazeny) Stanoveni oxidacne redukcniho potencialu SOP c. 107 (CSN 75 7367)","search_en":"Bathing water (swimming pools) Determination of oxidation-reduction potential SOP č. 107 (ČSN 75 7367)","search_zh":"游泳用水（游泳池） 氧化还原电位的测定 SOP č. 107 (ČSN 75 7367)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1e502490fb7730453db043b3","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"35","test_object":"Woda pitna","test_object_en":"Drinking water","test_object_zh":"饮用水","test_object_cs":"Pitná voda","methodology":"Oznaczanie zapachu i smaku","methodology_en":"Determination of odour and taste","methodology_zh":"嗅和味的测定","methodology_cs":"Stanovení pachu a chuti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zapachu i smaku","reference":"SOP č. 111 (ČSN 75 7340; ČSN EN 1622)","norm_bases":["SOP č. 111","ČSN 75 7340","ČSN EN 1622"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna Oznaczanie zapachu i smaku Pitná voda Stanovení pachu a chuti SOP č. 111 (ČSN 75 7340; ČSN EN 1622) Woda pitna Oznaczanie zapachu i smaku Pitna voda Stanoveni pachu a chuti SOP c. 111 (CSN 75 7340; CSN EN 1622)","search_en":"Drinking water Determination of odour and taste SOP č. 111 (ČSN 75 7340; ČSN EN 1622)","search_zh":"饮用水 嗅和味的测定 SOP č. 111 (ČSN 75 7340; ČSN EN 1622)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a1f0678b0cec11b9b68c8db4","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"1","test_object":"Woda pitna","test_object_en":"Drinking water","test_object_zh":"饮用水","test_object_cs":"Pitná voda","methodology":"Pobieranie próbek wody pitnej","methodology_en":"Sampling of drinking water","methodology_zh":"饮用水采样","methodology_cs":"Odběr vzorků pitné vody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wody pitnej","reference":"SOP č. V1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 252/2004 Sb.; Vyhl. č. 83/2014 Sb.; Vyhl.č. 70/2018 Sb.; Vyhl.č. 371/2023 Sb.)","norm_bases":["SOP č. V1","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-5","ČSN EN ISO 5667-14","ČSN EN ISO 19458","Vyhl. č. 252/2004 Sb.","Vyhl. č. 83/2014 Sb.","Vyhl.č. 70/2018 Sb.","Vyhl.č. 371/2023 Sb."],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna Pobieranie próbek wody pitnej Pitná voda Odběr vzorků pitné vody SOP č. V1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 252/2004 Sb.; Vyhl. č. 83/2014 Sb.; Vyhl.č. 70/2018 Sb.; Vyhl.č. 371/2023 Sb.) Woda pitna Pobieranie probek wody pitnej Pitna voda Odber vzorku pitne vody SOP c. V1 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-5; CSN EN ISO 5667-14; CSN EN ISO 19458; Vyhl. c. 252/2004 Sb.; Vyhl. c. 83/2014 Sb.; Vyhl.c. 70/2018 Sb.; Vyhl.c. 371/2023 Sb.)","search_en":"Drinking water Sampling of drinking water SOP č. V1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 252/2004 Sb.; Vyhl. č. 83/2014 Sb.; Vyhl.č. 70/2018 Sb.; Vyhl.č. 371/2023 Sb.)","search_zh":"饮用水 饮用水采样 SOP č. V1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 252/2004 Sb.; Vyhl. č. 83/2014 Sb.; Vyhl.č. 70/2018 Sb.; Vyhl.č. 371/2023 Sb.)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"419853079ce152e3ddf3ede9","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"2","test_object":"Woda w kąpieliskach (sztuczne kąpieliska – baseny)","test_object_en":"Bathing water (artificial swimming facilities – pools)","test_object_zh":"游泳用水（人工游泳场所 – 游泳池）","test_object_cs":"Voda ke koupání (umělá koupaliště - bazény)","methodology":"Pobieranie próbek wód w kąpieliskach","methodology_en":"Sampling of bathing water","methodology_zh":"游泳用水采样","methodology_cs":"Odběr vzorků vod ke koupání","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód w kąpieliskach","reference":"SOP č. V2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 238/2011 Sb.; Vyhl. č. 97/2014 Sb.; Předpis č. 1/2016 Sb.)","norm_bases":["SOP č. V2","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-14","ČSN EN ISO 19458","Vyhl. č. 238/2011 Sb.","Vyhl. č. 97/2014 Sb.","Předpis č. 1/2016 Sb."],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda w kąpieliskach (sztuczne kąpieliska – baseny) Pobieranie próbek wód w kąpieliskach Voda ke koupání (umělá koupaliště - bazény) Odběr vzorků vod ke koupání SOP č. V2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 238/2011 Sb.; Vyhl. č. 97/2014 Sb.; Předpis č. 1/2016 Sb.) Woda w kapieliskach (sztuczne kapieliska – baseny) Pobieranie probek wod w kapieliskach Voda ke koupani (umela koupaliste - bazeny) Odber vzorku vod ke koupani SOP c. V2 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-14; CSN EN ISO 19458; Vyhl. c. 238/2011 Sb.; Vyhl. c. 97/2014 Sb.; Predpis c. 1/2016 Sb.)","search_en":"Bathing water (artificial swimming facilities – pools) Sampling of bathing water SOP č. V2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 238/2011 Sb.; Vyhl. č. 97/2014 Sb.; Předpis č. 1/2016 Sb.)","search_zh":"游泳用水（人工游泳场所 – 游泳池） 游泳用水采样 SOP č. V2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 238/2011 Sb.; Vyhl. č. 97/2014 Sb.; Předpis č. 1/2016 Sb.)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5d1e76c4f1efa33a98902d8f","lab_id":"69ad52a4de79e566650fd328","country":"CZ","accr_number":"1260","accr_body":"ČIA","row_label":"3","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní voda","methodology":"Pobieranie próbek ścieków ręcznie i automatycznym próbnikiem","methodology_en":"Sampling of waste water manually and with an automatic sampler","methodology_zh":"手动和自动采样器采集废水样品","methodology_cs":"Odběr vzorků odpadních vod manuálně a automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków ręcznie i automatycznym próbnikiem","reference":"SOP č. V3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","norm_bases":["SOP č. V3","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków ręcznie i automatycznym próbnikiem Odpadní voda Odběr vzorků odpadních vod manuálně a automatickým vzorkovačem SOP č. V3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14) Scieki Pobieranie probek sciekow recznie i automatycznym probnikiem Odpadni voda Odber vzorku odpadnich vod manualne a automatickym vzorkovacem SOP c. V3 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14)","search_en":"Waste water Sampling of waste water manually and with an automatic sampler SOP č. V3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","search_zh":"废水 手动和自动采样器采集废水样品 SOP č. V3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}