{"lab":{"_id":"69ad52a4de79e566650fd322","accr_number":"1255","country":"CZ","accr_body":"ČIA","address":"Chudobín č.p. 83, 783 21","categories":["water","environment","food","microbiology"],"city":"Chudobín","imported_at":"2026-03-08T10:42:44.590Z","methods_count":84,"name":"LITOLAB, spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1255_566_2025_CS.pdf","1255_566_2025_EN.pdf"],"scope_summary":"Analizy chemiczne i mikrobiologiczne wód, wyciągów wodnych, kompostów, osadów ściekowych, osadów dennych, gleb, roślin, pasz, produktów rolnych i napojów, pobieranie próbek wód, gleb, gruntów, kompostów, osadów, odpadów, pasz, produktów rolnych i osadów dennych, w zakresie określonym w załączniku do świadectwa.","search_text":"litolab, spol. s r.o. chudobín č.p. 83, 783 21 other","status":"active","updated_at":"2026-03-08T14:52:09.668Z","valid_from":"","valid_until":"04-04-2028","website":"www.litolab.cz","parsed_at":"2026-09-28T12:00:00.000Z","email_confidence":"high","email_mx":true,"email_source":"https://www.litolab.cz","certificate_date":"25.06.2026","certificate_no":"312/2026","certificate_replaces":"566/2025 z 07.11.2025","en_official":true,"fields_of_testing":[{"codes":"","pl":"Analizy chemiczne i mikrobiologiczne wód, wyciągów wodnych, kompostów, osadów ściekowych, osadów dennych, gleb, roślin, pasz, produktów rolnych i napojów, pobieranie próbek wód, gleb, gruntów, kompostów, osadów, odpadów, pasz, produktów rolnych i osadów dennych, w zakresie określonym w załączniku do świadectwa.","en":"Chemical and microbiological analysis of water, aqueous extracts, composts, water treatment plant sludge, sediments, soils, plants, feedstuffs, agricultural products and beverages, sampling of water, soils, composts, sludge, waste, feedstuffs, agricultural products and sediments to the extent as specified in the appendix to this Certificate.","zh":"水、水浸出液、堆肥、污水处理厂污泥、沉积物、土壤、植物、饲料、农产品和饮料的化学和微生物分析，水、土壤、土、堆肥、污泥、废物、饲料、农产品和沉积物的采样，范围见本证书附件。","cs":"Chemické a mikrobiologické analýzy vod, vodných výluhů, kompostů, čistírenských kalů, sedimentů, půd, rostlin, krmiv, zemědělských produktů a nápojů, vzorkování vod, půd, zemin, kompostů, kalů, odpadů, krmiv, zemědělských produktů a sedimentů, vymezené přílohou tohoto osvědčení."}],"flexible_scope":true,"flexible_scope_url":"https://litolab.cz/cs/ke-stazeni/","has_en":true,"has_zh":true,"lab_division":"LABORATORIUM BADAWCZE","lab_division_cs":"ZKUŠEBNÍ LABORATOŘ","lab_division_en":"TESTING LABORATORY","lab_division_zh":"检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","scope_legend":[{"abbr":"TNV","pl":"branżowa norma techniczna gospodarki wodnej","en":"industry technical standard of water management","zh":"水务行业技术标准","cs":"odvětvová technická norma vodního hospodářství"},{"abbr":"JPP","pl":"jednolita procedura robocza (ÚKZÚZ Brno)","en":"unified working procedure (ÚKZÚZ Brno)","zh":"统一工作程序（布尔诺ÚKZÚZ）","cs":"jednotný pracovní postup (ÚKZÚZ Brno)"},{"abbr":"ÚKZÚZ","pl":"Centralny Instytut Kontroli i Badań Rolniczych","en":"Central Institute for Supervising and Testing in Agriculture","zh":"中央农业监督检测研究所","cs":"Ústřední kontrolní a zkušební ústav zemědělský"},{"abbr":"STN","pl":"słowacka norma techniczna","en":"Slovak technical standard","zh":"斯洛伐克技术标准","cs":"slovenská technická norma"},{"abbr":"DIN","pl":"niemiecka norma krajowa","en":"German national standard","zh":"德国国家标准","cs":"německá národní norma"},{"abbr":"ITP","pl":"izotachoforeza","en":"isotachophoresis","zh":"等速电泳","cs":"izotachoforéza"},{"abbr":"AAS","pl":"absorpcyjna spektrometria atomowa","en":"atomic absorption spectrometry","zh":"原子吸收光谱","cs":"atomová absorpční spektrometrie"},{"abbr":"ICP-OES","pl":"optyczny spektrometr emisyjny z plazmą indukcyjnie sprzężoną","en":"inductively coupled plasma optical emission spectrometer","zh":"电感耦合等离子体发射光谱仪","cs":"optický emisní spektrometr s indukčně vázanou plazmou"},{"abbr":"NEL","pl":"niepolarne substancje ekstrahowane","en":"non-polar extractable substances","zh":"非极性可萃取物","cs":"nepolární extrahované látky"},{"abbr":"EL","pl":"substancje ekstrahowalne","en":"extractable substances","zh":"可萃取物","cs":"extrahovatelné látky"},{"abbr":"HPLC","pl":"wysokosprawna chromatografia cieczowa","en":"high-performance liquid chromatography","zh":"高效液相色谱","cs":"vysokoúčinná kapalinová chromatografie"},{"abbr":"GC","pl":"chromatografia gazowa","en":"gas chromatography","zh":"气相色谱","cs":"plynová chromatografie"},{"abbr":"ECD","pl":"detektor wychwytu elektronów","en":"electron capture detector","zh":"电子捕获检测器","cs":"detektor elektronového záchytu"},{"abbr":"FID","pl":"detektor płomieniowo-jonizacyjny","en":"flame ionization detector","zh":"火焰离子化检测器","cs":"plamenoionizační detektor"},{"abbr":"MS","pl":"detektor mas","en":"mass detector","zh":"质谱检测器","cs":"hmotnostní detektor"},{"abbr":"NPD","pl":"detektor azotowo-fosforowy (płomieniowy z metalem alkalicznym)","en":"nitrogen-phosphorus detector (flame detector with alkali metal)","zh":"氮磷检测器","cs":"plamenoionizační detektor s alkalickým kovem"},{"abbr":"MZČR","pl":"Ministerstwo Zdrowia Republiki Czeskiej","en":"Ministry of Health of the Czech Republic","zh":"捷克共和国卫生部","cs":"Ministerstvo zdravotnictví České republiky"},{"abbr":"LC/MS/MS","pl":"chromatografia cieczowa z tandemową spektrometrią mas","en":"liquid chromatography with tandem mass spectrometry","zh":"液相色谱-串联质谱","cs":"kapalinová chromatografie s hmotnostním detektorem"},{"abbr":"IC/MS/MS","pl":"chromatografia jonowa z tandemową spektrometrią mas","en":"ion chromatography with tandem mass spectrometry","zh":"离子色谱-串联质谱","cs":"iontová chromatografie s hmotnostním detektorem"},{"abbr":"GC/ECD","pl":"chromatografia gazowa z detektorem wychwytu elektronów","en":"gas chromatography with electron capture detector","zh":"气相色谱-电子捕获检测器","cs":"plynová chromatografie s detektorem elektronového záchytu"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"7e3e6bf0ed0c1b0359b8fe9104cda04119e9e342ef509a4abec6bbb6e980dfe3","source_pdf_url":"https://www.cai.cz/OA/pdf/312_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/312_2026_EN.pdf"},"methods":[{"_id":"3d95479cff3793503db570bf","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"1","test_object":"Wody, wyciągi wodne","test_object_en":"Water, aqueous extracts","test_object_zh":"水、水浸出液","test_object_cs":"Vody, vodné výluhy","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"SOP - 1 (ČSN ISO 10523)","norm_bases":["SOP - 1","ČSN ISO 10523"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne Oznaczanie pH metodą potencjometryczną Vody, vodné výluhy Stanovení pH potenciometricky SOP - 1 (ČSN ISO 10523) Wody, wyciagi wodne Oznaczanie pH metoda potencjometryczna Vody, vodne vyluhy Stanoveni pH potenciometricky SOP - 1 (CSN ISO 10523)","search_en":"Water, aqueous extracts Determination of pH by potentiometry SOP - 1 (ČSN ISO 10523)","search_zh":"水、水浸出液 电位法测定pH SOP - 1 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2a6c3bbc8e35737377f20239","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"2","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie przewodności elektrycznej właściwej","methodology_en":"Determination of electrical conductivity","methodology_zh":"电导率测定","methodology_cs":"Stanovení elektrické konduktivity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej właściwej","reference":"SOP - 2 (ČSN EN 27888)","norm_bases":["SOP - 2","ČSN EN 27888"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie przewodności elektrycznej właściwej Vody, vodné výluhy odpadů Stanovení elektrické konduktivity SOP - 2 (ČSN EN 27888) Wody, wyciagi wodne z odpadow Oznaczanie przewodnosci elektrycznej wlasciwej Vody, vodne vyluhy odpadu Stanoveni elektricke konduktivity SOP - 2 (CSN EN 27888)","search_en":"Water, aqueous extracts of waste Determination of electrical conductivity SOP - 2 (ČSN EN 27888)","search_zh":"水、废物水浸出液 电导率测定 SOP - 2 (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0ae03cb35f5cc82916464725","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"3","test_object":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane, wody powierzchniowe, odcieki i ścieki","test_object_en":"Drinking, raw, processed and treated water, surface, leachate and waste water","test_object_zh":"饮用水、原水、成品水和处理水、地表水、渗滤液和废水","test_object_cs":"Pitné, surové, vyrobené a upravené vody, povrchové, průsakové a odpadní vody","methodology":"Oznaczanie BZT-5 po inkubacji z czujnikiem optycznym","methodology_en":"Determination of BOD-5 after incubation using an optical sensor","methodology_zh":"培养后光学传感器法测定BOD-5","methodology_cs":"Stanovení BSK-5 po inkubaci s optickým senzorem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie BZT-5 po inkubacji z czujnikiem optycznym","reference":"SOP - 3 (ČSN EN ISO 5815-1; ČSN ISO 17289)","norm_bases":["SOP - 3","ČSN EN ISO 5815-1","ČSN ISO 17289"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane, wody powierzchniowe, odcieki i ścieki Oznaczanie BZT-5 po inkubacji z czujnikiem optycznym Pitné, surové, vyrobené a upravené vody, povrchové, průsakové a odpadní vody Stanovení BSK-5 po inkubaci s optickým senzorem SOP - 3 (ČSN EN ISO 5815-1; ČSN ISO 17289) Wody przeznaczone do spozycia, surowe, uzdatnione i przygotowane, wody powierzchniowe, odcieki i scieki Oznaczanie BZT-5 po inkubacji z czujnikiem optycznym Pitne, surove, vyrobene a upravene vody, povrchove, prusakove a odpadni vody Stanoveni BSK-5 po inkubaci s optickym senzorem SOP - 3 (CSN EN ISO 5815-1; CSN ISO 17289)","search_en":"Drinking, raw, processed and treated water, surface, leachate and waste water Determination of BOD-5 after incubation using an optical sensor SOP - 3 (ČSN EN ISO 5815-1; ČSN ISO 17289)","search_zh":"饮用水、原水、成品水和处理水、地表水、渗滤液和废水 培养后光学传感器法测定BOD-5 SOP - 3 (ČSN EN ISO 5815-1; ČSN ISO 17289)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e14c442844b508b7564b5347","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"4","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie kwasowej pojemności neutralizacyjnej (KNK) metodą miareczkową","methodology_en":"Determination of acid neutralizing capacity (ANC) by titration","methodology_zh":"滴定法测定酸中和容量（ANC）","methodology_cs":"Stanovení kyselinové neutralizační kapacity (KNK) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kwasowej pojemności neutralizacyjnej (KNK) metodą miareczkową","reference":"SOP - 4 (ČSN EN ISO 9963-1)","norm_bases":["SOP - 4","ČSN EN ISO 9963-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie kwasowej pojemności neutralizacyjnej (KNK) metodą miareczkową Vody, vodné výluhy odpadů Stanovení kyselinové neutralizační kapacity (KNK) titračně SOP - 4 (ČSN EN ISO 9963-1) Wody, wyciagi wodne z odpadow Oznaczanie kwasowej pojemnosci neutralizacyjnej (KNK) metoda miareczkowa Vody, vodne vyluhy odpadu Stanoveni kyselinove neutralizacni kapacity (KNK) titracne SOP - 4 (CSN EN ISO 9963-1)","search_en":"Water, aqueous extracts of waste Determination of acid neutralizing capacity (ANC) by titration SOP - 4 (ČSN EN ISO 9963-1)","search_zh":"水、废物水浸出液 滴定法测定酸中和容量（ANC） SOP - 4 (ČSN EN ISO 9963-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c28d0b376bfb15841d2c2934","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"5","test_object":"Wody, wyciągi wodne","test_object_en":"Water, aqueous extracts","test_object_zh":"水、水浸出液","test_object_cs":"Vody, vodné výluhy","methodology":"Oznaczanie rozpuszczonych anionów metodą chromatografii jonowej","methodology_en":"Determination of dissolved anions by liquid ion chromatography","methodology_zh":"离子色谱法测定溶解性阴离子","methodology_cs":"Stanovení rozpuštěných aniontů metodou kapalinové chromatografie iontů","parameters":[{"name":"Bromiany","range":""},{"name":"chloryny","range":""},{"name":"chlorany","range":""},{"name":"bromki","range":""},{"name":"chlorki","range":""},{"name":"fluorki","range":""},{"name":"azotany","range":""},{"name":"azotyny","range":""},{"name":"siarczany","range":""},{"name":"fosforany","range":""}],"parameters_en":[{"name":"Bromates","range":""},{"name":"chlorites","range":""},{"name":"chlorates","range":""},{"name":"bromides","range":""},{"name":"chlorides","range":""},{"name":"fluorides","range":""},{"name":"nitrates","range":""},{"name":"nitrites","range":""},{"name":"sulphates","range":""},{"name":"phosphates","range":""}],"parameters_zh":[{"name":"溴酸盐","range":""},{"name":"亚氯酸盐","range":""},{"name":"氯酸盐","range":""},{"name":"溴化物","range":""},{"name":"氯化物","range":""},{"name":"氟化物","range":""},{"name":"硝酸盐","range":""},{"name":"亚硝酸盐","range":""},{"name":"硫酸盐","range":""},{"name":"磷酸盐","range":""}],"parameters_cs":[{"name":"Bromičnany","range":""},{"name":"chloritany","range":""},{"name":"chlorečnany","range":""},{"name":"bromidy","range":""},{"name":"chloridy","range":""},{"name":"fluoridy","range":""},{"name":"dusičnany","range":""},{"name":"dusitany","range":""},{"name":"sírany","range":""},{"name":"fosforečnany","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rozpuszczonych anionów metodą chromatografii jonowej\nZakres:\nBromiany\nchloryny\nchlorany\nbromki\nchlorki\nfluorki\nazotany\nazotyny\nsiarczany\nfosforany","reference":"SOP - 5 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)","norm_bases":["SOP - 5","ČSN EN ISO 10304-1","ČSN EN ISO 10304-4","ČSN EN ISO 15061"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne Oznaczanie rozpuszczonych anionów metodą chromatografii jonowej Bromiany  chloryny  chlorany  bromki  chlorki  fluorki  azotany  azotyny  siarczany  fosforany  Vody, vodné výluhy Stanovení rozpuštěných aniontů metodou kapalinové chromatografie iontů Bromičnany  chloritany  chlorečnany  bromidy  chloridy  fluoridy  dusičnany  dusitany  sírany  fosforečnany  SOP - 5 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061) Wody, wyciagi wodne Oznaczanie rozpuszczonych anionow metoda chromatografii jonowej Bromiany  chloryny  chlorany  bromki  chlorki  fluorki  azotany  azotyny  siarczany  fosforany  Vody, vodne vyluhy Stanoveni rozpustenych aniontu metodou kapalinove chromatografie iontu Bromicnany  chloritany  chlorecnany  bromidy  chloridy  fluoridy  dusicnany  dusitany  sirany  fosforecnany  SOP - 5 (CSN EN ISO 10304-1; CSN EN ISO 10304-4; CSN EN ISO 15061)","search_en":"Water, aqueous extracts Determination of dissolved anions by liquid ion chromatography Bromates  chlorites  chlorates  bromides  chlorides  fluorides  nitrates  nitrites  sulphates  phosphates  SOP - 5 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)","search_zh":"水、水浸出液 离子色谱法测定溶解性阴离子 溴酸盐  亚氯酸盐  氯酸盐  溴化物  氯化物  氟化物  硝酸盐  亚硝酸盐  硫酸盐  磷酸盐  SOP - 5 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9ed9e7836884f92845903359","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"6","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (ChZT-Mn) – miareczkowo","methodology_en":"Determination of chemical oxygen demand with permanganate (COD-Mn) by titration","methodology_zh":"滴定法测定高锰酸盐化学需氧量（COD-Mn）","methodology_cs":"Stanovení chemické spotřeby kyslíku manganistanem (CHSK-Mn) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (ChZT-Mn) – miareczkowo","reference":"SOP - 6 (ČSN EN ISO 8467)","norm_bases":["SOP - 6","ČSN EN ISO 8467"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (ChZT-Mn) – miareczkowo Vody, vodné výluhy odpadů Stanovení chemické spotřeby kyslíku manganistanem (CHSK-Mn) titračně SOP - 6 (ČSN EN ISO 8467) Wody, wyciagi wodne z odpadow Oznaczanie chemicznego zapotrzebowania na tlen metoda nadmanganianowa (ChZT-Mn) – miareczkowo Vody, vodne vyluhy odpadu Stanoveni chemicke spotreby kysliku manganistanem (CHSK-Mn) titracne SOP - 6 (CSN EN ISO 8467)","search_en":"Water, aqueous extracts of waste Determination of chemical oxygen demand with permanganate (COD-Mn) by titration SOP - 6 (ČSN EN ISO 8467)","search_zh":"水、废物水浸出液 滴定法测定高锰酸盐化学需氧量（COD-Mn） SOP - 6 (ČSN EN ISO 8467)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"32f3f9393b623601142227ed","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"7","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie jonów amonowych metodą spektrofotometryczną, azotu amonowego i nieorganicznego obliczeniowo","methodology_en":"Determination of ammonium by spectrophotometry, ammonia and inorganic nitrogen by calculation","methodology_zh":"分光光度法测定铵离子，计算氨氮和无机氮","methodology_cs":"Stanovení amonných iontů spektrofotometricky, amoniakálního a anorganického dusíku dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych metodą spektrofotometryczną, azotu amonowego i nieorganicznego obliczeniowo","reference":"SOP - 7 (ČSN ISO 7150-1)","norm_bases":["SOP - 7","ČSN ISO 7150-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie jonów amonowych metodą spektrofotometryczną, azotu amonowego i nieorganicznego obliczeniowo Vody, vodné výluhy odpadů Stanovení amonných iontů spektrofotometricky, amoniakálního a anorganického dusíku dopočtem SOP - 7 (ČSN ISO 7150-1) Wody, wyciagi wodne z odpadow Oznaczanie jonow amonowych metoda spektrofotometryczna, azotu amonowego i nieorganicznego obliczeniowo Vody, vodne vyluhy odpadu Stanoveni amonnych iontu spektrofotometricky, amoniakalniho a anorganickeho dusiku dopoctem SOP - 7 (CSN ISO 7150-1)","search_en":"Water, aqueous extracts of waste Determination of ammonium by spectrophotometry, ammonia and inorganic nitrogen by calculation SOP - 7 (ČSN ISO 7150-1)","search_zh":"水、废物水浸出液 分光光度法测定铵离子，计算氨氮和无机氮 SOP - 7 (ČSN ISO 7150-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"22cf253f0f123b419c442142","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"8","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie azotanów metodą spektrofotometryczną i azotu azotanowego obliczeniowo","methodology_en":"Determination of nitrate by spectrophotometry and nitrate nitrogen by calculation","methodology_zh":"分光光度法测定硝酸盐，计算硝酸盐氮","methodology_cs":"Stanovení dusičnanů spektrofotometricky a dusičnanového dusíku dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotanów metodą spektrofotometryczną i azotu azotanowego obliczeniowo","reference":"SOP - 8 (ČSN 75 7455)","norm_bases":["SOP - 8","ČSN 75 7455"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie azotanów metodą spektrofotometryczną i azotu azotanowego obliczeniowo Vody, vodné výluhy odpadů Stanovení dusičnanů spektrofotometricky a dusičnanového dusíku dopočtem SOP - 8 (ČSN 75 7455) Wody, wyciagi wodne z odpadow Oznaczanie azotanow metoda spektrofotometryczna i azotu azotanowego obliczeniowo Vody, vodne vyluhy odpadu Stanoveni dusicnanu spektrofotometricky a dusicnanoveho dusiku dopoctem SOP - 8 (CSN 75 7455)","search_en":"Water, aqueous extracts of waste Determination of nitrate by spectrophotometry and nitrate nitrogen by calculation SOP - 8 (ČSN 75 7455)","search_zh":"水、废物水浸出液 分光光度法测定硝酸盐，计算硝酸盐氮 SOP - 8 (ČSN 75 7455)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e4745ec651870d6a6b720ea7","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"9","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie azotynów metodą spektrofotometryczną i azotu azotynowego obliczeniowo","methodology_en":"Determination of nitrite by spectrophotometry and nitrite nitrogen by calculation","methodology_zh":"分光光度法测定亚硝酸盐，计算亚硝酸盐氮","methodology_cs":"Stanovení dusitanů spektrofotometricky a dusitanového dusíku dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotynów metodą spektrofotometryczną i azotu azotynowego obliczeniowo","reference":"SOP - 10 (ČSN EN 26777)","norm_bases":["SOP - 10","ČSN EN 26777"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie azotynów metodą spektrofotometryczną i azotu azotynowego obliczeniowo Vody, vodné výluhy odpadů Stanovení dusitanů spektrofotometricky a dusitanového dusíku dopočtem SOP - 10 (ČSN EN 26777) Wody, wyciagi wodne z odpadow Oznaczanie azotynow metoda spektrofotometryczna i azotu azotynowego obliczeniowo Vody, vodne vyluhy odpadu Stanoveni dusitanu spektrofotometricky a dusitanoveho dusiku dopoctem SOP - 10 (CSN EN 26777)","search_en":"Water, aqueous extracts of waste Determination of nitrite by spectrophotometry and nitrite nitrogen by calculation SOP - 10 (ČSN EN 26777)","search_zh":"水、废物水浸出液 分光光度法测定亚硝酸盐，计算亚硝酸盐氮 SOP - 10 (ČSN EN 26777)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c02faf3dbfa6d956693792ab","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"10","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie chlorków metodą miareczkową","methodology_en":"Determination of chlorides by titration","methodology_zh":"滴定法测定氯化物","methodology_cs":"Stanovení chloridů titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków metodą miareczkową","reference":"SOP - 11 (ČSN ISO 9297)","norm_bases":["SOP - 11","ČSN ISO 9297"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie chlorków metodą miareczkową Vody, vodné výluhy odpadů Stanovení chloridů titračně SOP - 11 (ČSN ISO 9297) Wody, wyciagi wodne z odpadow Oznaczanie chlorkow metoda miareczkowa Vody, vodne vyluhy odpadu Stanoveni chloridu titracne SOP - 11 (CSN ISO 9297)","search_en":"Water, aqueous extracts of waste Determination of chlorides by titration SOP - 11 (ČSN ISO 9297)","search_zh":"水、废物水浸出液 滴定法测定氯化物 SOP - 11 (ČSN ISO 9297)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cd978b4f892c1d1b8eb8bfb1","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"11","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dichromianową (ChZT-Cr) spektrofotometrycznie","methodology_en":"Determination of chemical oxygen demand with dichromate (COD-Cr) by spectrophotometry","methodology_zh":"分光光度法测定重铬酸盐化学需氧量（COD-Cr）","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem (CHSK-Cr) spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dichromianową (ChZT-Cr) spektrofotometrycznie","reference":"SOP - 13 (ČSN ISO 15705)","norm_bases":["SOP - 13","ČSN ISO 15705"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie chemicznego zapotrzebowania na tlen metodą dichromianową (ChZT-Cr) spektrofotometrycznie Vody, vodné výluhy odpadů Stanovení chemické spotřeby kyslíku dichromanem (CHSK-Cr) spektrofotometricky SOP - 13 (ČSN ISO 15705) Wody, wyciagi wodne z odpadow Oznaczanie chemicznego zapotrzebowania na tlen metoda dichromianowa (ChZT-Cr) spektrofotometrycznie Vody, vodne vyluhy odpadu Stanoveni chemicke spotreby kysliku dichromanem (CHSK-Cr) spektrofotometricky SOP - 13 (CSN ISO 15705)","search_en":"Water, aqueous extracts of waste Determination of chemical oxygen demand with dichromate (COD-Cr) by spectrophotometry SOP - 13 (ČSN ISO 15705)","search_zh":"水、废物水浸出液 分光光度法测定重铬酸盐化学需氧量（COD-Cr） SOP - 13 (ČSN ISO 15705)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"447685ee2e7386f7696ba341","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"12","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie substancji rozpuszczonych (RL) i rozpuszczonych soli nieorganicznych (RAS) metodą wagową","methodology_en":"Determination of dissolved solids (DS) and dissolved inorganic salts by gravimetry","methodology_zh":"重量法测定溶解性物质和溶解性无机盐","methodology_cs":"Stanovení rozpuštěných látek (RL) a rozpuštěných anorganických solí (RAS) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych (RL) i rozpuszczonych soli nieorganicznych (RAS) metodą wagową","reference":"SOP - 14 (ČSN 75 7346; ČSN 75 7347)","norm_bases":["SOP - 14","ČSN 75 7346","ČSN 75 7347"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie substancji rozpuszczonych (RL) i rozpuszczonych soli nieorganicznych (RAS) metodą wagową Vody, vodné výluhy odpadů Stanovení rozpuštěných látek (RL) a rozpuštěných anorganických solí (RAS) gravimetricky SOP - 14 (ČSN 75 7346; ČSN 75 7347) Wody, wyciagi wodne z odpadow Oznaczanie substancji rozpuszczonych (RL) i rozpuszczonych soli nieorganicznych (RAS) metoda wagowa Vody, vodne vyluhy odpadu Stanoveni rozpustenych latek (RL) a rozpustenych anorganickych soli (RAS) gravimetricky SOP - 14 (CSN 75 7346; CSN 75 7347)","search_en":"Water, aqueous extracts of waste Determination of dissolved solids (DS) and dissolved inorganic salts by gravimetry SOP - 14 (ČSN 75 7346; ČSN 75 7347)","search_zh":"水、废物水浸出液 重量法测定溶解性物质和溶解性无机盐 SOP - 14 (ČSN 75 7346; ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f96ea6811b34874e32bba443","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"13","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie zawiesiny metodą wagową","methodology_en":"Determination of suspended solids by gravimetry","methodology_zh":"重量法测定悬浮物","methodology_cs":"Stanovení nerozpuštěných látek gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesiny metodą wagową","reference":"SOP - 15 (ČSN EN 872)","norm_bases":["SOP - 15","ČSN EN 872"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie zawiesiny metodą wagową Vody, vodné výluhy odpadů Stanovení nerozpuštěných látek gravimetricky SOP - 15 (ČSN EN 872) Wody, wyciagi wodne z odpadow Oznaczanie zawiesiny metoda wagowa Vody, vodne vyluhy odpadu Stanoveni nerozpustenych latek gravimetricky SOP - 15 (CSN EN 872)","search_en":"Water, aqueous extracts of waste Determination of suspended solids by gravimetry SOP - 15 (ČSN EN 872)","search_zh":"水、废物水浸出液 重量法测定悬浮物 SOP - 15 (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"afde3068e47be9891ff95c1d","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"14","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie ortofosforanów metodą spektrofotometryczną","methodology_en":"Determination of orthophosphate by spectrophotometry","methodology_zh":"分光光度法测定正磷酸盐","methodology_cs":"Stanovení ortofosforečnanů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ortofosforanów metodą spektrofotometryczną","reference":"SOP - 16 (ČSN EN ISO 6878)","norm_bases":["SOP - 16","ČSN EN ISO 6878"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie ortofosforanów metodą spektrofotometryczną Vody, vodné výluhy odpadů Stanovení ortofosforečnanů spektrofotometricky SOP - 16 (ČSN EN ISO 6878) Wody, wyciagi wodne z odpadow Oznaczanie ortofosforanow metoda spektrofotometryczna Vody, vodne vyluhy odpadu Stanoveni ortofosforecnanu spektrofotometricky SOP - 16 (CSN EN ISO 6878)","search_en":"Water, aqueous extracts of waste Determination of orthophosphate by spectrophotometry SOP - 16 (ČSN EN ISO 6878)","search_zh":"水、废物水浸出液 分光光度法测定正磷酸盐 SOP - 16 (ČSN EN ISO 6878)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bef2680bba75adf883763cc3","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"15","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie fluorków metodą spektrofotometryczną","methodology_en":"Determination of fluoride by spectrophotometry","methodology_zh":"分光光度法测定氟化物","methodology_cs":"Stanovení fluoridů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fluorków metodą spektrofotometryczną","reference":"SOP - 17 (TNV 75 7431)","norm_bases":["SOP - 17","TNV 75 7431"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie fluorków metodą spektrofotometryczną Vody, vodné výluhy odpadů Stanovení fluoridů spektrofotometricky SOP - 17 (TNV 75 7431) Wody, wyciagi wodne z odpadow Oznaczanie fluorkow metoda spektrofotometryczna Vody, vodne vyluhy odpadu Stanoveni fluoridu spektrofotometricky SOP - 17 (TNV 75 7431)","search_en":"Water, aqueous extracts of waste Determination of fluoride by spectrophotometry SOP - 17 (TNV 75 7431)","search_zh":"水、废物水浸出液 分光光度法测定氟化物 SOP - 17 (TNV 75 7431)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fb4293823015245150f32923","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"16","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie anionowych substancji powierzchniowo czynnych metodą spektrofotometryczną","methodology_en":"Determination of anionic surfactants by spectrophotometry","methodology_zh":"分光光度法测定阴离子表面活性剂","methodology_cs":"Stanovení aniontových tenzidů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie anionowych substancji powierzchniowo czynnych metodą spektrofotometryczną","reference":"SOP - 18 (ČSN EN 903)","norm_bases":["SOP - 18","ČSN EN 903"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie anionowych substancji powierzchniowo czynnych metodą spektrofotometryczną Vody, vodné výluhy odpadů Stanovení aniontových tenzidů spektrofotometricky SOP - 18 (ČSN EN 903) Wody, wyciagi wodne z odpadow Oznaczanie anionowych substancji powierzchniowo czynnych metoda spektrofotometryczna Vody, vodne vyluhy odpadu Stanoveni aniontovych tenzidu spektrofotometricky SOP - 18 (CSN EN 903)","search_en":"Water, aqueous extracts of waste Determination of anionic surfactants by spectrophotometry SOP - 18 (ČSN EN 903)","search_zh":"水、废物水浸出液 分光光度法测定阴离子表面活性剂 SOP - 18 (ČSN EN 903)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5c4cbd6e9033016e61926e31","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"17","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną","methodology_en":"Determination of univalent phenols by spectrophotometry","methodology_zh":"分光光度法测定一元酚","methodology_cs":"Stanovení jednosytných fenolů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną","reference":"SOP - 19 (ČSN ISO 6439)","norm_bases":["SOP - 19","ČSN ISO 6439"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną Vody, vodné výluhy odpadů Stanovení jednosytných fenolů spektrofotometricky SOP - 19 (ČSN ISO 6439) Wody, wyciagi wodne z odpadow Oznaczanie fenoli jednowodorotlenowych metoda spektrofotometryczna Vody, vodne vyluhy odpadu Stanoveni jednosytnych fenolu spektrofotometricky SOP - 19 (CSN ISO 6439)","search_en":"Water, aqueous extracts of waste Determination of univalent phenols by spectrophotometry SOP - 19 (ČSN ISO 6439)","search_zh":"水、废物水浸出液 分光光度法测定一元酚 SOP - 19 (ČSN ISO 6439)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e8666dd0643b32043c3391f4","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"18","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie chromu sześciowartościowego metodą spektrofotometryczną","methodology_en":"Determination of hexavalent chromium by spectrophotometry","methodology_zh":"分光光度法测定六价铬","methodology_cs":"Stanovení šestimocného chromu spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chromu sześciowartościowego metodą spektrofotometryczną","reference":"SOP - 20 (ČSN ISO 11083)","norm_bases":["SOP - 20","ČSN ISO 11083"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie chromu sześciowartościowego metodą spektrofotometryczną Vody, vodné výluhy odpadů Stanovení šestimocného chromu spektrofotometricky SOP - 20 (ČSN ISO 11083) Wody, wyciagi wodne z odpadow Oznaczanie chromu szesciowartosciowego metoda spektrofotometryczna Vody, vodne vyluhy odpadu Stanoveni sestimocneho chromu spektrofotometricky SOP - 20 (CSN ISO 11083)","search_en":"Water, aqueous extracts of waste Determination of hexavalent chromium by spectrophotometry SOP - 20 (ČSN ISO 11083)","search_zh":"水、废物水浸出液 分光光度法测定六价铬 SOP - 20 (ČSN ISO 11083)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4234f977f2d803f42698dad5","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"19","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metodą ICP-OES i twardości ogólnej obliczeniowo","methodology_en":"Determination of Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn by ICP-OES and total hardness by calculation","methodology_zh":"ICP-OES法测定Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn，计算总硬度","methodology_cs":"Stanovení Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metodou ICP-OES a celkové tvrdosti dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metodą ICP-OES i twardości ogólnej obliczeniowo","reference":"SOP – 21 (ČSN EN ISO 11885; ČSN EN 12457-4; ČSN EN ISO 15587-1)","norm_bases":["SOP – 21","ČSN EN ISO 11885","ČSN EN 12457-4","ČSN EN ISO 15587-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metodą ICP-OES i twardości ogólnej obliczeniowo Vody, vodné výluhy odpadů Stanovení Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metodou ICP-OES a celkové tvrdosti dopočtem SOP – 21 (ČSN EN ISO 11885; ČSN EN 12457-4; ČSN EN ISO 15587-1) Wody, wyciagi wodne z odpadow Oznaczanie Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metoda ICP-OES i twardosci ogolnej obliczeniowo Vody, vodne vyluhy odpadu Stanoveni Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metodou ICP-OES a celkove tvrdosti dopoctem SOP – 21 (CSN EN ISO 11885; CSN EN 12457-4; CSN EN ISO 15587-1)","search_en":"Water, aqueous extracts of waste Determination of Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn by ICP-OES and total hardness by calculation SOP – 21 (ČSN EN ISO 11885; ČSN EN 12457-4; ČSN EN ISO 15587-1)","search_zh":"水、废物水浸出液 ICP-OES法测定Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn，计算总硬度 SOP – 21 (ČSN EN ISO 11885; ČSN EN 12457-4; ČSN EN ISO 15587-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"223773e7e6c220cfd980083a","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"20","test_object":"Matryce stałe, mineralizaty matryc stałych","test_object_en":"Solid matrices, mineralizates of solid matrices","test_object_zh":"固体基质、固体基质消解液","test_object_cs":"Pevné matrice, mineralizáty pevných matric","methodology":"Oznaczanie Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metodą ICP-OES","methodology_en":"Determination of Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn by ICP-OES","methodology_zh":"ICP-OES法测定Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn","methodology_cs":"Stanovení Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metodou ICP-OES","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metodą ICP-OES","reference":"SOP - 21 A (ČSN EN ISO 11885; JPP ÚKZÚZ Brno Analýza půd II 2011; Analýza rostlinného materiálu 2005)","norm_bases":["SOP - 21 A","ČSN EN ISO 11885","JPP ÚKZÚZ Brno Analýza půd II 2011","Analýza rostlinného materiálu 2005"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Materiał pochodzenia roślinnego lub zwierzęcego, żywność, owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy, pasze, nawozy, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, piasek z piaskownic, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Material of plant or animal origin, food, fruit and vegetables, cereal grain, oilseeds, spices, feedstuffs, fertilisers, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, sandpit sand, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"植物或动物源材料、食品、水果和蔬菜、谷物籽粒、油料种子、香料、饲料、肥料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、沙坑沙、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Materiál rostlinného nebo živočišného původu, potraviny, plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření, krmiva, hnojiva, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, písek z pískovišť, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Matryce stałe, mineralizaty matryc stałych Oznaczanie Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metodą ICP-OES Pevné matrice, mineralizáty pevných matric Stanovení Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metodou ICP-OES SOP - 21 A (ČSN EN ISO 11885; JPP ÚKZÚZ Brno Analýza půd II 2011; Analýza rostlinného materiálu 2005) Matryce stale, mineralizaty matryc stalych Oznaczanie Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metoda ICP-OES Pevne matrice, mineralizaty pevnych matric Stanoveni Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn metodou ICP-OES SOP - 21 A (CSN EN ISO 11885; JPP UKZUZ Brno Analyza pud II 2011; Analyza rostlinneho materialu 2005)","search_en":"Solid matrices, mineralizates of solid matrices Determination of Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn by ICP-OES SOP - 21 A (ČSN EN ISO 11885; JPP ÚKZÚZ Brno Analýza půd II 2011; Analýza rostlinného materiálu 2005)","search_zh":"固体基质、固体基质消解液 ICP-OES法测定Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, S, Sb, Se, Tl, V, Zn SOP - 21 A (ČSN EN ISO 11885; JPP ÚKZÚZ Brno Analýza půd II 2011; Analýza rostlinného materiálu 2005)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ff3690c0b738e16af2e34073","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"21","test_object":"Wody, wyciągi wodne z odpadów, matryce stałe","test_object_en":"Water, aqueous extracts of waste, solid matrices","test_object_zh":"水、废物水浸出液、固体基质","test_object_cs":"Vody, vodné výluhy odpadů, Pevné matrice","methodology":"Oznaczanie rtęci całkowitej jednofunkcyjnym AAS","methodology_en":"Determination of total mercury by single-purpose AAS","methodology_zh":"专用原子吸收光谱仪测定总汞","methodology_cs":"Stanovení veškeré rtuti jednoúčelovým AAS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci całkowitej jednofunkcyjnym AAS","reference":"SOP - 22 (ČSN 75 7440)","norm_bases":["SOP - 22","ČSN 75 7440"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu | Materiał pochodzenia roślinnego lub zwierzęcego, żywność, owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy, pasze, nawozy, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, piasek z piaskownic, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended | Material of plant or animal origin, food, fruit and vegetables, cereal grain, oilseeds, spices, feedstuffs, fertilisers, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, sandpit sand, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液 | 植物或动物源材料、食品、水果和蔬菜、谷物籽粒、油料种子、香料、饲料、肥料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、沙坑沙、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění | Materiál rostlinného nebo živočišného původu, potraviny, plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření, krmiva, hnojiva, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, písek z pískovišť, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów, matryce stałe Oznaczanie rtęci całkowitej jednofunkcyjnym AAS Vody, vodné výluhy odpadů, Pevné matrice Stanovení veškeré rtuti jednoúčelovým AAS SOP - 22 (ČSN 75 7440) Wody, wyciagi wodne z odpadow, matryce stale Oznaczanie rteci calkowitej jednofunkcyjnym AAS Vody, vodne vyluhy odpadu, Pevne matrice Stanoveni veskere rtuti jednoucelovym AAS SOP - 22 (CSN 75 7440)","search_en":"Water, aqueous extracts of waste, solid matrices Determination of total mercury by single-purpose AAS SOP - 22 (ČSN 75 7440)","search_zh":"水、废物水浸出液、固体基质 专用原子吸收光谱仪测定总汞 SOP - 22 (ČSN 75 7440)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"26fa68ba00fc26f60584ccac","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"22","test_object":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe i basenowe, woda z automatów z napojami, napoje bezalkoholowe, matryce stałe","test_object_en":"Drinking, bottled, raw, processed, treated, surface and pool water, water from drinks dispensers, non-alcoholic beverages, solid matrices","test_object_zh":"饮用水、瓶装水、原水、成品水、处理水、地表水和泳池水、饮料机用水、无醇饮料、固体基质","test_object_cs":"Pitné, balené, surové, vyrobené, upravené, povrchové a bazénové vody, vody z nápojových automatů, nealkoholické nápoje, pevné matrice","methodology":"Oznaczanie bakterii z grupy coli i E. coli metodą filtrów membranowych","methodology_en":"Detection and enumeration of coliform bacteria and E-coli by membrane filtration","methodology_zh":"膜过滤法测定大肠菌群和大肠杆菌","methodology_cs":"Stanovení koliformních bakterií a E-coli metodou membránových filtrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii z grupy coli i E. coli metodą filtrów membranowych","reference":"SOP - 25 (ČSN EN ISO 9308-1:2015)","norm_bases":["SOP - 25","ČSN EN ISO 9308-1:2015"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe i basenowe, woda z automatów z napojami, napoje bezalkoholowe, matryce stałe Oznaczanie bakterii z grupy coli i E. coli metodą filtrów membranowych Pitné, balené, surové, vyrobené, upravené, povrchové a bazénové vody, vody z nápojových automatů, nealkoholické nápoje, pevné matrice Stanovení koliformních bakterií a E-coli metodou membránových filtrů SOP - 25 (ČSN EN ISO 9308-1:2015) Wody przeznaczone do spozycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe i basenowe, woda z automatow z napojami, napoje bezalkoholowe, matryce stale Oznaczanie bakterii z grupy coli i E. coli metoda filtrow membranowych Pitne, balene, surove, vyrobene, upravene, povrchove a bazenove vody, vody z napojovych automatu, nealkoholicke napoje, pevne matrice Stanoveni koliformnich bakterii a E-coli metodou membranovych filtru SOP - 25 (CSN EN ISO 9308-1:2015)","search_en":"Drinking, bottled, raw, processed, treated, surface and pool water, water from drinks dispensers, non-alcoholic beverages, solid matrices Detection and enumeration of coliform bacteria and E-coli by membrane filtration SOP - 25 (ČSN EN ISO 9308-1:2015)","search_zh":"饮用水、瓶装水、原水、成品水、处理水、地表水和泳池水、饮料机用水、无醇饮料、固体基质 膜过滤法测定大肠菌群和大肠杆菌 SOP - 25 (ČSN EN ISO 9308-1:2015)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7b6109bd72ffc1c134f6928a","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"23","test_object":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe i basenowe, woda z automatów z napojami, napoje bezalkoholowe, matryce stałe","test_object_en":"Drinking, bottled, raw, processed, treated, surface and pool water, water from drinks dispensers, non-alcoholic beverages, solid matrices","test_object_zh":"饮用水、瓶装水、原水、成品水、处理水、地表水和泳池水、饮料机用水、无醇饮料、固体基质","test_object_cs":"Pitné, balené, surové, vyrobené, upravené, povrchové a bazénové vody, vody z nápojových automatů, nealkoholické nápoje, pevné matrice","methodology":"Oznaczanie termotolerancyjnych bakterii z grupy coli metodą filtrów membranowych","methodology_en":"Detection and enumeration of thermotolerant coliform bacteria by membrane filtration","methodology_zh":"膜过滤法测定耐热大肠菌群","methodology_cs":"Stanovení termotolerantních koliformních bakterií metodou membránových filtrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie termotolerancyjnych bakterii z grupy coli metodą filtrów membranowych","reference":"SOP - 26 (ČSN 75 7835; AHEM 7/2001)","norm_bases":["SOP - 26","ČSN 75 7835","AHEM 7/2001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"AHEM 7/2001 = oznaczanie mikroorganizmów wskaźnikowych dla kryteriów mikrobiologicznych stosowania osadów na gruntach rolnych w rozumieniu rozporządzenia nr 382/2001 Sb. o warunkach stosowania przetworzonych osadów na gruntach rolnych, Praga 2001.","note_en":"AHEM 7/2001 = Determination of indicator microorganisms for microbiological criteria for the use of sludge on agricultural land under Decree No. 382/2001 Coll. on the conditions of use of treated sludge on agricultural land, Prague 2001.","note_zh":"AHEM 7/2001 = 按第382/2001号法令（关于处理污泥农用条件）测定污泥农用微生物标准的指示微生物，布拉格，2001年。","note_cs":"AHEM 7/2001 = Stanovení indikátorových mikroorganismů pro mikrobiologická kritéria pro použití kalů na zemědělské půdě ve smyslu vyhlášky č. 382/2001 Sb., o podmínkách použití upravovaných kalů na zemědělské půdě, Praha 2001.","search_text":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe i basenowe, woda z automatów z napojami, napoje bezalkoholowe, matryce stałe Oznaczanie termotolerancyjnych bakterii z grupy coli metodą filtrów membranowych Pitné, balené, surové, vyrobené, upravené, povrchové a bazénové vody, vody z nápojových automatů, nealkoholické nápoje, pevné matrice Stanovení termotolerantních koliformních bakterií metodou membránových filtrů SOP - 26 (ČSN 75 7835; AHEM 7/2001) Wody przeznaczone do spozycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe i basenowe, woda z automatow z napojami, napoje bezalkoholowe, matryce stale Oznaczanie termotolerancyjnych bakterii z grupy coli metoda filtrow membranowych Pitne, balene, surove, vyrobene, upravene, povrchove a bazenove vody, vody z napojovych automatu, nealkoholicke napoje, pevne matrice Stanoveni termotolerantnich koliformnich bakterii metodou membranovych filtru SOP - 26 (CSN 75 7835; AHEM 7/2001)","search_en":"Drinking, bottled, raw, processed, treated, surface and pool water, water from drinks dispensers, non-alcoholic beverages, solid matrices Detection and enumeration of thermotolerant coliform bacteria by membrane filtration SOP - 26 (ČSN 75 7835; AHEM 7/2001)","search_zh":"饮用水、瓶装水、原水、成品水、处理水、地表水和泳池水、饮料机用水、无醇饮料、固体基质 膜过滤法测定耐热大肠菌群 SOP - 26 (ČSN 75 7835; AHEM 7/2001)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"035e56c667ddbe90a4150aa0","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"24","test_object":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe i basenowe, woda z automatów z napojami, napoje bezalkoholowe, matryce stałe","test_object_en":"Drinking, bottled, raw, processed, treated, surface and pool water, water from drinks dispensers, non-alcoholic beverages, solid matrices","test_object_zh":"饮用水、瓶装水、原水、成品水、处理水、地表水和泳池水、饮料机用水、无醇饮料、固体基质","test_object_cs":"Pitné, balené, surové, vyrobené, upravené, povrchové a bazénové vody, vody z nápojových automatů, nealkoholické nápoje, pevné matrice","methodology":"Oznaczanie enterokoków jelitowych metodą filtrów membranowych","methodology_en":"Detection and enumeration of intestinal enterococci by membrane filtration method","methodology_zh":"膜过滤法测定肠道肠球菌","methodology_cs":"Stanovení intestinálních enterokoků metodou membránových filtrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie enterokoków jelitowych metodą filtrów membranowych","reference":"SOP – 27 (ČSN EN ISO 7899-2; AHEM 7/2001)","norm_bases":["SOP – 27","ČSN EN ISO 7899-2","AHEM 7/2001"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Materiał pochodzenia roślinnego lub zwierzęcego, żywność, owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy, pasze, nawozy, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, piasek z piaskownic, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu | AHEM 7/2001 = oznaczanie mikroorganizmów wskaźnikowych dla kryteriów mikrobiologicznych stosowania osadów na gruntach rolnych w rozumieniu rozporządzenia nr 382/2001 Sb. o warunkach stosowania przetworzonych osadów na gruntach rolnych, Praga 2001.","note_en":"Material of plant or animal origin, food, fruit and vegetables, cereal grain, oilseeds, spices, feedstuffs, fertilisers, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, sandpit sand, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended | AHEM 7/2001 = Determination of indicator microorganisms for microbiological criteria for the use of sludge on agricultural land under Decree No. 382/2001 Coll. on the conditions of use of treated sludge on agricultural land, Prague 2001.","note_zh":"植物或动物源材料、食品、水果和蔬菜、谷物籽粒、油料种子、香料、饲料、肥料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、沙坑沙、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料 | AHEM 7/2001 = 按第382/2001号法令（关于处理污泥农用条件）测定污泥农用微生物标准的指示微生物，布拉格，2001年。","note_cs":"Materiál rostlinného nebo živočišného původu, potraviny, plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření, krmiva, hnojiva, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, písek z pískovišť, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění | AHEM 7/2001 = Stanovení indikátorových mikroorganismů pro mikrobiologická kritéria pro použití kalů na zemědělské půdě ve smyslu vyhlášky č. 382/2001 Sb., o podmínkách použití upravovaných kalů na zemědělské půdě, Praha 2001.","search_text":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe i basenowe, woda z automatów z napojami, napoje bezalkoholowe, matryce stałe Oznaczanie enterokoków jelitowych metodą filtrów membranowych Pitné, balené, surové, vyrobené, upravené, povrchové a bazénové vody, vody z nápojových automatů, nealkoholické nápoje, pevné matrice Stanovení intestinálních enterokoků metodou membránových filtrů SOP – 27 (ČSN EN ISO 7899-2; AHEM 7/2001) Wody przeznaczone do spozycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe i basenowe, woda z automatow z napojami, napoje bezalkoholowe, matryce stale Oznaczanie enterokokow jelitowych metoda filtrow membranowych Pitne, balene, surove, vyrobene, upravene, povrchove a bazenove vody, vody z napojovych automatu, nealkoholicke napoje, pevne matrice Stanoveni intestinalnich enterokoku metodou membranovych filtru SOP – 27 (CSN EN ISO 7899-2; AHEM 7/2001)","search_en":"Drinking, bottled, raw, processed, treated, surface and pool water, water from drinks dispensers, non-alcoholic beverages, solid matrices Detection and enumeration of intestinal enterococci by membrane filtration method SOP – 27 (ČSN EN ISO 7899-2; AHEM 7/2001)","search_zh":"饮用水、瓶装水、原水、成品水、处理水、地表水和泳池水、饮料机用水、无醇饮料、固体基质 膜过滤法测定肠道肠球菌 SOP – 27 (ČSN EN ISO 7899-2; AHEM 7/2001)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5fb08202360e029f249dcaf5","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"25","test_object":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe i basenowe, woda z automatów z napojami i napoje bezalkoholowe","test_object_en":"Drinking, bottled, raw, processed, treated, surface and pool water, water from drinks dispensers and non-alcoholic beverages","test_object_zh":"饮用水、瓶装水、原水、成品水、处理水、地表水和泳池水、饮料机用水和无醇饮料","test_object_cs":"Pitné, balené, surové, vyrobené, upravené, povrchové a bazénové vody, vody z nápojových automatů a nealkoholické nápoje","methodology":"Oznaczanie liczby drobnoustrojów zdolnych do wzrostu przez posiew na agarowe podłoże hodowlane a) w 22 °C b) w 36 °C","methodology_en":"Enumeration of culturable microorganisms by inoculation in an agar culture medium a) at 22 °C b) at 36 °C","methodology_zh":"琼脂培养基接种法测定可培养微生物 a) 22 °C b) 36 °C","methodology_cs":"Stanovení kultivovatelných mikroorganismů očkováním do agarového kultivačního média a) při 22 °C b) při 36 °C","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby drobnoustrojów zdolnych do wzrostu przez posiew na agarowe podłoże hodowlane a) w 22 °C b) w 36 °C","reference":"SOP - 30 (ČSN EN ISO 6222)","norm_bases":["SOP - 30","ČSN EN ISO 6222"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe i basenowe, woda z automatów z napojami i napoje bezalkoholowe Oznaczanie liczby drobnoustrojów zdolnych do wzrostu przez posiew na agarowe podłoże hodowlane a) w 22 °C b) w 36 °C Pitné, balené, surové, vyrobené, upravené, povrchové a bazénové vody, vody z nápojových automatů a nealkoholické nápoje Stanovení kultivovatelných mikroorganismů očkováním do agarového kultivačního média a) při 22 °C b) při 36 °C SOP - 30 (ČSN EN ISO 6222) Wody przeznaczone do spozycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe i basenowe, woda z automatow z napojami i napoje bezalkoholowe Oznaczanie liczby drobnoustrojow zdolnych do wzrostu przez posiew na agarowe podloze hodowlane a) w 22 °C b) w 36 °C Pitne, balene, surove, vyrobene, upravene, povrchove a bazenove vody, vody z napojovych automatu a nealkoholicke napoje Stanoveni kultivovatelnych mikroorganismu ockovanim do agaroveho kultivacniho media a) pri 22 °C b) pri 36 °C SOP - 30 (CSN EN ISO 6222)","search_en":"Drinking, bottled, raw, processed, treated, surface and pool water, water from drinks dispensers and non-alcoholic beverages Enumeration of culturable microorganisms by inoculation in an agar culture medium a) at 22 °C b) at 36 °C SOP - 30 (ČSN EN ISO 6222)","search_zh":"饮用水、瓶装水、原水、成品水、处理水、地表水和泳池水、饮料机用水和无醇饮料 琼脂培养基接种法测定可培养微生物 a) 22 °C b) 36 °C SOP - 30 (ČSN EN ISO 6222)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"03e1e811a8777a9751b3212e","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"26","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie pH wymiennego metodą potencjometryczną","methodology_en":"Determination of exchangeable pH by potentiometry","methodology_zh":"电位法测定交换性pH","methodology_cs":"Stanovení výměnného pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH wymiennego metodą potencjometryczną","reference":"SOP - 31 (JPP ÚKZÚZ Brno 2010, Analýza půd I; ČSN EN ISO 10390; ČSN 46 5735)","norm_bases":["SOP - 31","JPP ÚKZÚZ Brno 2010, Analýza půd I","ČSN EN ISO 10390","ČSN 46 5735"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Materiał pochodzenia roślinnego lub zwierzęcego, żywność, owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy, pasze, nawozy, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, piasek z piaskownic, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Material of plant or animal origin, food, fruit and vegetables, cereal grain, oilseeds, spices, feedstuffs, fertilisers, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, sandpit sand, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"植物或动物源材料、食品、水果和蔬菜、谷物籽粒、油料种子、香料、饲料、肥料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、沙坑沙、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Materiál rostlinného nebo živočišného původu, potraviny, plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření, krmiva, hnojiva, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, písek z pískovišť, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Matryce stałe Oznaczanie pH wymiennego metodą potencjometryczną Pevné matrice Stanovení výměnného pH potenciometricky SOP - 31 (JPP ÚKZÚZ Brno 2010, Analýza půd I; ČSN EN ISO 10390; ČSN 46 5735) Matryce stale Oznaczanie pH wymiennego metoda potencjometryczna Pevne matrice Stanoveni vymenneho pH potenciometricky SOP - 31 (JPP UKZUZ Brno 2010, Analyza pud I; CSN EN ISO 10390; CSN 46 5735)","search_en":"Solid matrices Determination of exchangeable pH by potentiometry SOP - 31 (JPP ÚKZÚZ Brno 2010, Analýza půd I; ČSN EN ISO 10390; ČSN 46 5735)","search_zh":"固体基质 电位法测定交换性pH SOP - 31 (JPP ÚKZÚZ Brno 2010, Analýza půd I; ČSN EN ISO 10390; ČSN 46 5735)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43a8bacf0289b5359c54b57f","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"27","test_object":"Wszystkie rodzaje gleb","test_object_en":"All types of soils","test_object_zh":"各类土壤","test_object_cs":"Všechny druhy půd","methodology":"Oznaczanie Ca, Mg, K i P w wyciągu wg Mehlicha III metodą ICP-OES","methodology_en":"Determination of Ca, Mg, K and P in extract according to Mehlich III by ICP-OES","methodology_zh":"ICP-OES法测定Mehlich III浸提液中的Ca、Mg、K和P","methodology_cs":"Stanovení Ca, Mg, K a P ve výluhu dle Mehlicha III metodou ICP-OES","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Ca, Mg, K i P w wyciągu wg Mehlicha III metodą ICP-OES","reference":"SOP - 32 (JPP ÚKZÚZ Brno 2010, Analýza půd I)","norm_bases":["SOP - 32","JPP ÚKZÚZ Brno 2010, Analýza půd I"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wszystkie rodzaje gleb Oznaczanie Ca, Mg, K i P w wyciągu wg Mehlicha III metodą ICP-OES Všechny druhy půd Stanovení Ca, Mg, K a P ve výluhu dle Mehlicha III metodou ICP-OES SOP - 32 (JPP ÚKZÚZ Brno 2010, Analýza půd I) Wszystkie rodzaje gleb Oznaczanie Ca, Mg, K i P w wyciagu wg Mehlicha III metoda ICP-OES Vsechny druhy pud Stanoveni Ca, Mg, K a P ve vyluhu dle Mehlicha III metodou ICP-OES SOP - 32 (JPP UKZUZ Brno 2010, Analyza pud I)","search_en":"All types of soils Determination of Ca, Mg, K and P in extract according to Mehlich III by ICP-OES SOP - 32 (JPP ÚKZÚZ Brno 2010, Analýza půd I)","search_zh":"各类土壤 ICP-OES法测定Mehlich III浸提液中的Ca、Mg、K和P SOP - 32 (JPP ÚKZÚZ Brno 2010, Analýza půd I)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9d69a44a392d14ca6690790a","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"28","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie mętności metodą nefelometryczną","methodology_en":"Determination of turbidity by nephelometry","methodology_zh":"散射法测定浊度","methodology_cs":"Stanovení zákalu nefelometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mętności metodą nefelometryczną","reference":"SOP - 33 (ČSN EN ISO 7027-1)","norm_bases":["SOP - 33","ČSN EN ISO 7027-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun","search_text":"Wody Oznaczanie mętności metodą nefelometryczną Vody Stanovení zákalu nefelometricky SOP - 33 (ČSN EN ISO 7027-1) Wody Oznaczanie metnosci metoda nefelometryczna Vody Stanoveni zakalu nefelometricky SOP - 33 (CSN EN ISO 7027-1)","search_en":"Water Determination of turbidity by nephelometry SOP - 33 (ČSN EN ISO 7027-1)","search_zh":"水 散射法测定浊度 SOP - 33 (ČSN EN ISO 7027-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d5982b511ec2fab9c5f3a160","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"29","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie barwy metodą kolorymetryczną","methodology_en":"Determination of colour by colorimetry","methodology_zh":"比色法测定色度","methodology_cs":"Stanovení barvy kolorimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie barwy metodą kolorymetryczną","reference":"SOP - 34 (ČSN EN ISO 7887)","norm_bases":["SOP - 34","ČSN EN ISO 7887"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun","search_text":"Wody Oznaczanie barwy metodą kolorymetryczną Vody Stanovení barvy kolorimetricky SOP - 34 (ČSN EN ISO 7887) Wody Oznaczanie barwy metoda kolorymetryczna Vody Stanoveni barvy kolorimetricky SOP - 34 (CSN EN ISO 7887)","search_en":"Water Determination of colour by colorimetry SOP - 34 (ČSN EN ISO 7887)","search_zh":"水 比色法测定色度 SOP - 34 (ČSN EN ISO 7887)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3c6021f2c6996a72c0021e05","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"30","test_object":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane i powierzchniowe","test_object_en":"Drinking, bottled, raw, processed, treated and surface water","test_object_zh":"饮用水、瓶装水、原水、成品水、处理水和地表水","test_object_cs":"Pitné, balené, surové, vyrobené, upravené a povrchové vody","methodology":"Oznaczanie absorbancji","methodology_en":"Determination of absorbance","methodology_zh":"吸光度测定","methodology_cs":"Stanovení absorbance","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie absorbancji","reference":"SOP - 35 (ČSN 75 7360)","norm_bases":["SOP - 35","ČSN 75 7360"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane i powierzchniowe Oznaczanie absorbancji Pitné, balené, surové, vyrobené, upravené a povrchové vody Stanovení absorbance SOP - 35 (ČSN 75 7360) Wody przeznaczone do spozycia, butelkowane, surowe, uzdatnione, przygotowane i powierzchniowe Oznaczanie absorbancji Pitne, balene, surove, vyrobene, upravene a povrchove vody Stanoveni absorbance SOP - 35 (CSN 75 7360)","search_en":"Drinking, bottled, raw, processed, treated and surface water Determination of absorbance SOP - 35 (ČSN 75 7360)","search_zh":"饮用水、瓶装水、原水、成品水、处理水和地表水 吸光度测定 SOP - 35 (ČSN 75 7360)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fcf421ff3e1353cb3bd5a77b","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"31","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie cyjanków ogólnych metodą spektrofotometryczną","methodology_en":"Determination of total cyanide by spectrophotometry","methodology_zh":"分光光度法测定总氰化物","methodology_cs":"Stanovení veškerých kyanidů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cyjanków ogólnych metodą spektrofotometryczną","reference":"SOP - 36 (ČSN 75 7415)","norm_bases":["SOP - 36","ČSN 75 7415"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie cyjanków ogólnych metodą spektrofotometryczną Vody, vodné výluhy odpadů Stanovení veškerých kyanidů spektrofotometricky SOP - 36 (ČSN 75 7415) Wody, wyciagi wodne z odpadow Oznaczanie cyjankow ogolnych metoda spektrofotometryczna Vody, vodne vyluhy odpadu Stanoveni veskerych kyanidu spektrofotometricky SOP - 36 (CSN 75 7415)","search_en":"Water, aqueous extracts of waste Determination of total cyanide by spectrophotometry SOP - 36 (ČSN 75 7415)","search_zh":"水、废物水浸出液 分光光度法测定总氰化物 SOP - 36 (ČSN 75 7415)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"09db9195bef36a69e35c9346","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"32","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie NELIR metodą spektrometrii w podczerwieni","methodology_en":"Determination of NELIR by infrared spectrometry method","methodology_zh":"红外光谱法测定NELIR","methodology_cs":"Stanovení NELIR metodou infračervené spektrometrie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie NELIR metodą spektrometrii w podczerwieni","reference":"SOP - 37 (ČSN 75 7505:1998)","norm_bases":["SOP - 37","ČSN 75 7505:1998"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun","search_text":"Wody Oznaczanie NELIR metodą spektrometrii w podczerwieni Vody Stanovení NELIR metodou infračervené spektrometrie SOP - 37 (ČSN 75 7505:1998) Wody Oznaczanie NELIR metoda spektrometrii w podczerwieni Vody Stanoveni NELIR metodou infracervene spektrometrie SOP - 37 (CSN 75 7505:1998)","search_en":"Water Determination of NELIR by infrared spectrometry method SOP - 37 (ČSN 75 7505:1998)","search_zh":"水 红外光谱法测定NELIR SOP - 37 (ČSN 75 7505:1998)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ae9d9fead27593ea747c05ca","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"33","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie ELIR metodą spektrometrii w podczerwieni","methodology_en":"Determination of ELIR by infrared spectrometry method","methodology_zh":"红外光谱法测定ELIR","methodology_cs":"Stanovení ELIR metodou infračervené spektrometrie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ELIR metodą spektrometrii w podczerwieni","reference":"SOP - 38 (ČSN 75 7506)","norm_bases":["SOP - 38","ČSN 75 7506"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun","search_text":"Wody Oznaczanie ELIR metodą spektrometrii w podczerwieni Vody Stanovení ELIR metodou infračervené spektrometrie SOP - 38 (ČSN 75 7506) Wody Oznaczanie ELIR metoda spektrometrii w podczerwieni Vody Stanoveni ELIR metodou infracervene spektrometrie SOP - 38 (CSN 75 7506)","search_en":"Water Determination of ELIR by infrared spectrometry method SOP - 38 (ČSN 75 7506)","search_zh":"水 红外光谱法测定ELIR SOP - 38 (ČSN 75 7506)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9ae29421338f9a6ee62e4d30","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"34","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie azotu metodą mineralizacji utleniającej nadtlenodisiarczanem","methodology_en":"Determination of nitrogen – method using oxidative digestion with peroxodisulfate","methodology_zh":"过硫酸盐氧化消解法测定氮","methodology_cs":"Stanovení dusíku metodou oxidační mineralizace peroxodisíranem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu metodą mineralizacji utleniającej nadtlenodisiarczanem","reference":"SOP - 39 (ČSN EN ISO 11905-1)","norm_bases":["SOP - 39","ČSN EN ISO 11905-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun","search_text":"Wody Oznaczanie azotu metodą mineralizacji utleniającej nadtlenodisiarczanem Vody Stanovení dusíku metodou oxidační mineralizace peroxodisíranem SOP - 39 (ČSN EN ISO 11905-1) Wody Oznaczanie azotu metoda mineralizacji utleniajacej nadtlenodisiarczanem Vody Stanoveni dusiku metodou oxidacni mineralizace peroxodisiranem SOP - 39 (CSN EN ISO 11905-1)","search_en":"Water Determination of nitrogen – method using oxidative digestion with peroxodisulfate SOP - 39 (ČSN EN ISO 11905-1)","search_zh":"水 过硫酸盐氧化消解法测定氮 SOP - 39 (ČSN EN ISO 11905-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3f4db34b926dd468edc87eb6","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"35","test_object":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe oraz woda z kąpielisk, basenów i saun","test_object_en":"Drinking, bottled, raw, processed, treated, surface water and water from bathing places, swimming pools and saunas","test_object_zh":"饮用水、瓶装水、原水、成品水、处理水、地表水及游泳场所、泳池和桑拿用水","test_object_cs":"Pitné, balené, surové, vyrobené, upravené, povrchové vody a vody z koupališť, bazénů a saun","methodology":"Oznaczanie chloru wolnego i całkowitego metodą fotometryczną zestawem firmy HACH/HANNA instruments oraz chloru związanego obliczeniowo","methodology_en":"Determination of free and total chlorine by photometry by HACH/HANNA Instruments set and bound chlorine by calculation","methodology_zh":"使用HACH/HANNA instruments试剂套装光度法测定游离氯和总氯，计算结合氯","methodology_cs":"Stanovení volného a celkového chloru fotometricky setem firmy HACH/HANNA instruments a vázaného chloru dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chloru wolnego i całkowitego metodą fotometryczną zestawem firmy HACH/HANNA instruments oraz chloru związanego obliczeniowo","reference":"SOP – 40 návod firmy HACH; návod firmy HANNA instruments)","norm_bases":["SOP – 40","návod firmy HACH","návod firmy HANNA instruments"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe oraz woda z kąpielisk, basenów i saun Oznaczanie chloru wolnego i całkowitego metodą fotometryczną zestawem firmy HACH/HANNA instruments oraz chloru związanego obliczeniowo Pitné, balené, surové, vyrobené, upravené, povrchové vody a vody z koupališť, bazénů a saun Stanovení volného a celkového chloru fotometricky setem firmy HACH/HANNA instruments a vázaného chloru dopočtem SOP – 40 návod firmy HACH; návod firmy HANNA instruments) Wody przeznaczone do spozycia, butelkowane, surowe, uzdatnione, przygotowane, powierzchniowe oraz woda z kapielisk, basenow i saun Oznaczanie chloru wolnego i calkowitego metoda fotometryczna zestawem firmy HACH/HANNA instruments oraz chloru zwiazanego obliczeniowo Pitne, balene, surove, vyrobene, upravene, povrchove vody a vody z koupalist, bazenu a saun Stanoveni volneho a celkoveho chloru fotometricky setem firmy HACH/HANNA instruments a vazaneho chloru dopoctem SOP – 40 navod firmy HACH; navod firmy HANNA instruments)","search_en":"Drinking, bottled, raw, processed, treated, surface water and water from bathing places, swimming pools and saunas Determination of free and total chlorine by photometry by HACH/HANNA Instruments set and bound chlorine by calculation SOP – 40 návod firmy HACH; návod firmy HANNA instruments)","search_zh":"饮用水、瓶装水、原水、成品水、处理水、地表水及游泳场所、泳池和桑拿用水 使用HACH/HANNA instruments试剂套装光度法测定游离氯和总氯，计算结合氯 SOP – 40 návod firmy HACH; návod firmy HANNA instruments)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f57e13d7a40b27d83d80dc54","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"36","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie temperatury","methodology_en":"Determination of temperature","methodology_zh":"温度测定","methodology_cs":"Stanovení teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury","reference":"SOP - 41 (ČSN 75 7342)","norm_bases":["SOP - 41","ČSN 75 7342"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":true,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun","search_text":"Wody Oznaczanie temperatury Vody Stanovení teploty SOP - 41 (ČSN 75 7342) Wody Oznaczanie temperatury Vody Stanoveni teploty SOP - 41 (CSN 75 7342)","search_en":"Water Determination of temperature SOP - 41 (ČSN 75 7342)","search_zh":"水 温度测定 SOP - 41 (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c1ea18b36112b26c7f033212","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"37","test_object":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane i powierzchniowe, woda z automatów z napojami, napoje bezalkoholowe, woda z kąpielisk, basenów i saun","test_object_en":"Drinking, bottled, raw, processed, treated and surface water, water from drinks dispensers, non-alcoholic beverages, water from bathing places, swimming pools and saunas","test_object_zh":"饮用水、瓶装水、原水、成品水、处理水和地表水、饮料机用水、无醇饮料、游泳场所、泳池和桑拿用水","test_object_cs":"Pitné, balené, surové, vyrobené, upravené a povrchové vody, vody z nápojových automatů, nealkoholické nápoje, vody z koupališť, bazénů a saun","methodology":"Oznaczanie bakterii z rodzaju Legionella metodą filtrów membranowych","methodology_en":"Detection and enumeration of Legionella by membrane filtration","methodology_zh":"膜过滤法测定军团菌","methodology_cs":"Stanovení bakterií rodu Legionella metodou membránových filtrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii z rodzaju Legionella metodą filtrów membranowych","reference":"SOP - 43 (ČSN EN ISO 11731)","norm_bases":["SOP - 43","ČSN EN ISO 11731"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane i powierzchniowe, woda z automatów z napojami, napoje bezalkoholowe, woda z kąpielisk, basenów i saun Oznaczanie bakterii z rodzaju Legionella metodą filtrów membranowych Pitné, balené, surové, vyrobené, upravené a povrchové vody, vody z nápojových automatů, nealkoholické nápoje, vody z koupališť, bazénů a saun Stanovení bakterií rodu Legionella metodou membránových filtrů SOP - 43 (ČSN EN ISO 11731) Wody przeznaczone do spozycia, butelkowane, surowe, uzdatnione, przygotowane i powierzchniowe, woda z automatow z napojami, napoje bezalkoholowe, woda z kapielisk, basenow i saun Oznaczanie bakterii z rodzaju Legionella metoda filtrow membranowych Pitne, balene, surove, vyrobene, upravene a povrchove vody, vody z napojovych automatu, nealkoholicke napoje, vody z koupalist, bazenu a saun Stanoveni bakterii rodu Legionella metodou membranovych filtru SOP - 43 (CSN EN ISO 11731)","search_en":"Drinking, bottled, raw, processed, treated and surface water, water from drinks dispensers, non-alcoholic beverages, water from bathing places, swimming pools and saunas Detection and enumeration of Legionella by membrane filtration SOP - 43 (ČSN EN ISO 11731)","search_zh":"饮用水、瓶装水、原水、成品水、处理水和地表水、饮料机用水、无醇饮料、游泳场所、泳池和桑拿用水 膜过滤法测定军团菌 SOP - 43 (ČSN EN ISO 11731)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"534c0b0d3e684be6a452fab1","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"38","test_object":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane i powierzchniowe, woda z automatów z napojami, napoje bezalkoholowe, woda z kąpielisk, basenów i saun","test_object_en":"Drinking, bottled, raw, processed, treated and surface water, water from drinks dispensers, non-alcoholic beverages, water from bathing places, swimming pools and saunas","test_object_zh":"饮用水、瓶装水、原水、成品水、处理水和地表水、饮料机用水、无醇饮料、游泳场所、泳池和桑拿用水","test_object_cs":"Pitné, balené, surové, vyrobené, upravené a povrchové vody, vody z nápojových automatů, nealkoholické nápoje, vody z koupališť, bazénů a saun","methodology":"Oznaczanie Pseudomonas aeruginosa metodą filtrów membranowych","methodology_en":"Detection and enumeration of Pseudomonas aeruginosa by membrane filtration","methodology_zh":"膜过滤法测定铜绿假单胞菌","methodology_cs":"Stanovení Pseudomonas aeruginosa metodou membránových filtrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Pseudomonas aeruginosa metodą filtrów membranowych","reference":"SOP – 44 (ČSN EN ISO 16266)","norm_bases":["SOP – 44","ČSN EN ISO 16266"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane i powierzchniowe, woda z automatów z napojami, napoje bezalkoholowe, woda z kąpielisk, basenów i saun Oznaczanie Pseudomonas aeruginosa metodą filtrów membranowych Pitné, balené, surové, vyrobené, upravené a povrchové vody, vody z nápojových automatů, nealkoholické nápoje, vody z koupališť, bazénů a saun Stanovení Pseudomonas aeruginosa metodou membránových filtrů SOP – 44 (ČSN EN ISO 16266) Wody przeznaczone do spozycia, butelkowane, surowe, uzdatnione, przygotowane i powierzchniowe, woda z automatow z napojami, napoje bezalkoholowe, woda z kapielisk, basenow i saun Oznaczanie Pseudomonas aeruginosa metoda filtrow membranowych Pitne, balene, surove, vyrobene, upravene a povrchove vody, vody z napojovych automatu, nealkoholicke napoje, vody z koupalist, bazenu a saun Stanoveni Pseudomonas aeruginosa metodou membranovych filtru SOP – 44 (CSN EN ISO 16266)","search_en":"Drinking, bottled, raw, processed, treated and surface water, water from drinks dispensers, non-alcoholic beverages, water from bathing places, swimming pools and saunas Detection and enumeration of Pseudomonas aeruginosa by membrane filtration SOP – 44 (ČSN EN ISO 16266)","search_zh":"饮用水、瓶装水、原水、成品水、处理水和地表水、饮料机用水、无醇饮料、游泳场所、泳池和桑拿用水 膜过滤法测定铜绿假单胞菌 SOP – 44 (ČSN EN ISO 16266)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"275e017477675759d48c26d6","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"39","test_object":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane i powierzchniowe, woda z automatów z napojami, napoje bezalkoholowe, woda z kąpielisk, basenów i saun","test_object_en":"Drinking, bottled, raw, processed, treated and surface water, water from drinks dispensers, non-alcoholic beverages, water from bathing places, swimming pools and saunas","test_object_zh":"饮用水、瓶装水、原水、成品水、处理水和地表水、饮料机用水、无醇饮料、游泳场所、泳池和桑拿用水","test_object_cs":"Pitné, balené, surové, vyrobené, upravené a povrchové vody, vody z nápojových automatů, nealkoholické nápoje, vody z koupališť, bazénů a saun","methodology":"Oznaczanie gronkowców koagulazododatnich metodą filtrów membranowych","methodology_en":"Enumeration of coagulase-positive staphylococci by membrane filtration","methodology_zh":"膜过滤法测定凝固酶阳性葡萄球菌","methodology_cs":"Stanovení koagulázopozitivních stafylokoků metodou membránových filtrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gronkowców koagulazododatnich metodą filtrów membranowych","reference":"SOP - 45 (ČSN EN ISO 6888-1; ČSN EN ISO 6888-2)","norm_bases":["SOP - 45","ČSN EN ISO 6888-1","ČSN EN ISO 6888-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, przygotowane i powierzchniowe, woda z automatów z napojami, napoje bezalkoholowe, woda z kąpielisk, basenów i saun Oznaczanie gronkowców koagulazododatnich metodą filtrów membranowych Pitné, balené, surové, vyrobené, upravené a povrchové vody, vody z nápojových automatů, nealkoholické nápoje, vody z koupališť, bazénů a saun Stanovení koagulázopozitivních stafylokoků metodou membránových filtrů SOP - 45 (ČSN EN ISO 6888-1; ČSN EN ISO 6888-2) Wody przeznaczone do spozycia, butelkowane, surowe, uzdatnione, przygotowane i powierzchniowe, woda z automatow z napojami, napoje bezalkoholowe, woda z kapielisk, basenow i saun Oznaczanie gronkowcow koagulazododatnich metoda filtrow membranowych Pitne, balene, surove, vyrobene, upravene a povrchove vody, vody z napojovych automatu, nealkoholicke napoje, vody z koupalist, bazenu a saun Stanoveni koagulazopozitivnich stafylokoku metodou membranovych filtru SOP - 45 (CSN EN ISO 6888-1; CSN EN ISO 6888-2)","search_en":"Drinking, bottled, raw, processed, treated and surface water, water from drinks dispensers, non-alcoholic beverages, water from bathing places, swimming pools and saunas Enumeration of coagulase-positive staphylococci by membrane filtration SOP - 45 (ČSN EN ISO 6888-1; ČSN EN ISO 6888-2)","search_zh":"饮用水、瓶装水、原水、成品水、处理水和地表水、饮料机用水、无醇饮料、游泳场所、泳池和桑拿用水 膜过滤法测定凝固酶阳性葡萄球菌 SOP - 45 (ČSN EN ISO 6888-1; ČSN EN ISO 6888-2)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"af894a2ff12e5ecaefd42b93","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"40","test_object":"Pasze, matryce stałe, napoje bezalkoholowe","test_object_en":"Feedstuffs, solid matrices, non-alcoholic beverages","test_object_zh":"饲料、固体基质、无醇饮料","test_object_cs":"Krmiva, pevné matrice, nealkoholické nápoje","methodology":"Oznaczanie liczby drożdży i pleśni techniką liczenia kolonii","methodology_en":"Enumeration of yeasts and moulds by colony count technique","methodology_zh":"菌落计数法测定酵母和霉菌数","methodology_cs":"Stanovení počtu kvasinek a plísní technikou počítání kolonií","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby drożdży i pleśni techniką liczenia kolonii","reference":"SOP – 46 (ČSN ISO 21527-1; ČSN ISO 21527-2)","norm_bases":["SOP – 46","ČSN ISO 21527-1","ČSN ISO 21527-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Materiał pochodzenia roślinnego lub zwierzęcego, żywność, owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy, pasze, nawozy, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, piasek z piaskownic, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Material of plant or animal origin, food, fruit and vegetables, cereal grain, oilseeds, spices, feedstuffs, fertilisers, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, sandpit sand, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"植物或动物源材料、食品、水果和蔬菜、谷物籽粒、油料种子、香料、饲料、肥料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、沙坑沙、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Materiál rostlinného nebo živočišného původu, potraviny, plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření, krmiva, hnojiva, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, písek z pískovišť, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Pasze, matryce stałe, napoje bezalkoholowe Oznaczanie liczby drożdży i pleśni techniką liczenia kolonii Krmiva, pevné matrice, nealkoholické nápoje Stanovení počtu kvasinek a plísní technikou počítání kolonií SOP – 46 (ČSN ISO 21527-1; ČSN ISO 21527-2) Pasze, matryce stale, napoje bezalkoholowe Oznaczanie liczby drozdzy i plesni technika liczenia kolonii Krmiva, pevne matrice, nealkoholicke napoje Stanoveni poctu kvasinek a plisni technikou pocitani kolonii SOP – 46 (CSN ISO 21527-1; CSN ISO 21527-2)","search_en":"Feedstuffs, solid matrices, non-alcoholic beverages Enumeration of yeasts and moulds by colony count technique SOP – 46 (ČSN ISO 21527-1; ČSN ISO 21527-2)","search_zh":"饲料、固体基质、无醇饮料 菌落计数法测定酵母和霉菌数 SOP – 46 (ČSN ISO 21527-1; ČSN ISO 21527-2)","categories":["microbiology","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dde16f581c080be5ae45a361","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"41","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie substancji humusowych metodą spektrofotometryczną","methodology_en":"Determination of humic substances by spectrophotometry","methodology_zh":"分光光度法测定腐殖质","methodology_cs":"Stanovení huminových látek spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji humusowych metodą spektrofotometryczną","reference":"SOP – 47 (ČSN 75 7536)","norm_bases":["SOP – 47","ČSN 75 7536"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun","search_text":"Wody Oznaczanie substancji humusowych metodą spektrofotometryczną Vody Stanovení huminových látek spektrofotometricky SOP – 47 (ČSN 75 7536) Wody Oznaczanie substancji humusowych metoda spektrofotometryczna Vody Stanoveni huminovych latek spektrofotometricky SOP – 47 (CSN 75 7536)","search_en":"Water Determination of humic substances by spectrophotometry SOP – 47 (ČSN 75 7536)","search_zh":"水 分光光度法测定腐殖质 SOP – 47 (ČSN 75 7536)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8853868b602c6676e8c0ed39","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"42","test_object":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione i przygotowane","test_object_en":"Drinking, bottled, raw, processed and treated water","test_object_zh":"饮用水、瓶装水、原水、成品水和处理水","test_object_cs":"Pitné, balené, surové, vyrobené a upravené vody","methodology":"Oznaczanie zapachu i smaku metodą orientacyjnej analizy sensorycznej","methodology_en":"Determination of odour and flavour by preliminary sensory analysis","methodology_zh":"初步感官分析法测定气味和味道","methodology_cs":"Stanovení pachu a chuti orientační senzorickou analýzou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zapachu i smaku metodą orientacyjnej analizy sensorycznej","reference":"SOP – 48 ČSN 75 7340; ČSN EN 1622)","norm_bases":["SOP – 48","ČSN 75 7340","ČSN EN 1622"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione i przygotowane Oznaczanie zapachu i smaku metodą orientacyjnej analizy sensorycznej Pitné, balené, surové, vyrobené a upravené vody Stanovení pachu a chuti orientační senzorickou analýzou SOP – 48 ČSN 75 7340; ČSN EN 1622) Wody przeznaczone do spozycia, butelkowane, surowe, uzdatnione i przygotowane Oznaczanie zapachu i smaku metoda orientacyjnej analizy sensorycznej Pitne, balene, surove, vyrobene a upravene vody Stanoveni pachu a chuti orientacni senzorickou analyzou SOP – 48 CSN 75 7340; CSN EN 1622)","search_en":"Drinking, bottled, raw, processed and treated water Determination of odour and flavour by preliminary sensory analysis SOP – 48 ČSN 75 7340; ČSN EN 1622)","search_zh":"饮用水、瓶装水、原水、成品水和处理水 初步感官分析法测定气味和味道 SOP – 48 ČSN 75 7340; ČSN EN 1622)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2045c2bed512f9250765d2d5","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"43","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie wilgotności (suchej masy) metodą wagową","methodology_en":"Determination of moisture (dry matter) content by gravimetry","methodology_zh":"重量法测定水分（干物质）","methodology_cs":"Stanovení vlhkosti (sušiny) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności (suchej masy) metodą wagową","reference":"SOP – 61 (ČSN 46 7092-3; Nařízení komise (ES) č. 152/2009, příloha č. III, \"A\"; ČSN 46 5735)","norm_bases":["SOP – 61","ČSN 46 7092-3","Nařízení komise (ES) č. 152/2009","ČSN 46 5735"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Materiał pochodzenia roślinnego lub zwierzęcego, żywność, owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy, pasze, nawozy, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, piasek z piaskownic, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Material of plant or animal origin, food, fruit and vegetables, cereal grain, oilseeds, spices, feedstuffs, fertilisers, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, sandpit sand, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"植物或动物源材料、食品、水果和蔬菜、谷物籽粒、油料种子、香料、饲料、肥料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、沙坑沙、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Materiál rostlinného nebo živočišného původu, potraviny, plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření, krmiva, hnojiva, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, písek z pískovišť, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Matryce stałe Oznaczanie wilgotności (suchej masy) metodą wagową Pevné matrice Stanovení vlhkosti (sušiny) gravimetricky SOP – 61 (ČSN 46 7092-3; Nařízení komise (ES) č. 152/2009, příloha č. III, \"A\"; ČSN 46 5735) Matryce stale Oznaczanie wilgotnosci (suchej masy) metoda wagowa Pevne matrice Stanoveni vlhkosti (susiny) gravimetricky SOP – 61 (CSN 46 7092-3; Narizeni komise (ES) c. 152/2009, priloha c. III, \"A\"; CSN 46 5735)","search_en":"Solid matrices Determination of moisture (dry matter) content by gravimetry SOP – 61 (ČSN 46 7092-3; Nařízení komise (ES) č. 152/2009, příloha č. III, \"A\"; ČSN 46 5735)","search_zh":"固体基质 重量法测定水分（干物质） SOP – 61 (ČSN 46 7092-3; Nařízení komise (ES) č. 152/2009, příloha č. III, \"A\"; ČSN 46 5735)","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"adae1b2ea29c9d8d9ee7f378","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"44","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie azotu ogólnego i substancji azotowych metodą Dumasa","methodology_en":"Determination of total nitrogen and nitrogenous substances – Dumas method","methodology_zh":"杜马斯法测定总氮和含氮物质","methodology_cs":"Stanovení celkového dusíku a dusíkatých látek dle Dumase","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu ogólnego i substancji azotowych metodą Dumasa","reference":"SOP - 62 (ČSN EN ISO 16634-1)","norm_bases":["SOP - 62","ČSN EN ISO 16634-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Materiał pochodzenia roślinnego lub zwierzęcego, żywność, owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy, pasze, nawozy, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, piasek z piaskownic, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Material of plant or animal origin, food, fruit and vegetables, cereal grain, oilseeds, spices, feedstuffs, fertilisers, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, sandpit sand, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"植物或动物源材料、食品、水果和蔬菜、谷物籽粒、油料种子、香料、饲料、肥料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、沙坑沙、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Materiál rostlinného nebo živočišného původu, potraviny, plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření, krmiva, hnojiva, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, písek z pískovišť, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Matryce stałe Oznaczanie azotu ogólnego i substancji azotowych metodą Dumasa Pevné matrice Stanovení celkového dusíku a dusíkatých látek dle Dumase SOP - 62 (ČSN EN ISO 16634-1) Matryce stale Oznaczanie azotu ogolnego i substancji azotowych metoda Dumasa Pevne matrice Stanoveni celkoveho dusiku a dusikatych latek dle Dumase SOP - 62 (CSN EN ISO 16634-1)","search_en":"Solid matrices Determination of total nitrogen and nitrogenous substances – Dumas method SOP - 62 (ČSN EN ISO 16634-1)","search_zh":"固体基质 杜马斯法测定总氮和含氮物质 SOP - 62 (ČSN EN ISO 16634-1)","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e79ad89d9183ee79f8df2f36","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"45","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie popiołu (substancji organicznych) metodą wagową","methodology_en":"Determination of ash (organic substances) by gravimetry","methodology_zh":"重量法测定灰分（有机物）","methodology_cs":"Stanovení popela (organických látek) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie popiołu (substancji organicznych) metodą wagową","reference":"SOP – 63 (Nařízení komise (ES) č. 152/2009, příloha III, \"M\"; ČSN 46 5735)","norm_bases":["SOP – 63","Nařízení komise (ES) č. 152/2009","ČSN 46 5735"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Materiał pochodzenia roślinnego lub zwierzęcego, żywność, owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy, pasze, nawozy, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, piasek z piaskownic, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Material of plant or animal origin, food, fruit and vegetables, cereal grain, oilseeds, spices, feedstuffs, fertilisers, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, sandpit sand, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"植物或动物源材料、食品、水果和蔬菜、谷物籽粒、油料种子、香料、饲料、肥料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、沙坑沙、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Materiál rostlinného nebo živočišného původu, potraviny, plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření, krmiva, hnojiva, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, písek z pískovišť, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Matryce stałe Oznaczanie popiołu (substancji organicznych) metodą wagową Pevné matrice Stanovení popela (organických látek) gravimetricky SOP – 63 (Nařízení komise (ES) č. 152/2009, příloha III, \"M\"; ČSN 46 5735) Matryce stale Oznaczanie popiolu (substancji organicznych) metoda wagowa Pevne matrice Stanoveni popela (organickych latek) gravimetricky SOP – 63 (Narizeni komise (ES) c. 152/2009, priloha III, \"M\"; CSN 46 5735)","search_en":"Solid matrices Determination of ash (organic substances) by gravimetry SOP – 63 (Nařízení komise (ES) č. 152/2009, příloha III, \"M\"; ČSN 46 5735)","search_zh":"固体基质 重量法测定灰分（有机物） SOP – 63 (Nařízení komise (ES) č. 152/2009, příloha III, \"M\"; ČSN 46 5735)","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fea1535713db2f7ab24359c3","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"46","test_object":"Pasze","test_object_en":"Feedstuffs","test_object_zh":"饲料","test_object_cs":"Krmiva","methodology":"Oznaczanie tłuszczu metodą wagową","methodology_en":"Determination of fat by gravimetry","methodology_zh":"重量法测定脂肪","methodology_cs":"Stanovení tuku gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tłuszczu metodą wagową","reference":"SOP – 64 (Nařízení komise (ES) č. 152/2009, příloha III, \"H\")","norm_bases":["SOP – 64","Nařízení komise (ES) č. 152/2009"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze Oznaczanie tłuszczu metodą wagową Krmiva Stanovení tuku gravimetricky SOP – 64 (Nařízení komise (ES) č. 152/2009, příloha III, \"H\") Pasze Oznaczanie tluszczu metoda wagowa Krmiva Stanoveni tuku gravimetricky SOP – 64 (Narizeni komise (ES) c. 152/2009, priloha III, \"H\")","search_en":"Feedstuffs Determination of fat by gravimetry SOP – 64 (Nařízení komise (ES) č. 152/2009, příloha III, \"H\")","search_zh":"饲料 重量法测定脂肪 SOP – 64 (Nařízení komise (ES) č. 152/2009, příloha III, \"H\")","categories":["food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a870ae0a56090c70c6833a48","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"47","test_object":"Pasze, pofermenty z biogazowni","test_object_en":"Feedstuffs, digestates from biogas plants","test_object_zh":"饲料、沼气站沼渣","test_object_cs":"Krmiva, digestáty z BPS","methodology":"Oznaczanie kwasów kiszonkowych metodą izotachoforezy (ITP)","methodology_en":"Determination of silage acids by ITP method","methodology_zh":"等速电泳法测定青贮酸","methodology_cs":"Stanovení silážních kyselin metodou ITP","parameters":[{"name":"Kwas octowy","range":""},{"name":"kwas mlekowy","range":""},{"name":"kwas propionowy","range":""},{"name":"kwas masłowy","range":""}],"parameters_en":[{"name":"Acetic acid","range":""},{"name":"lactic acid","range":""},{"name":"propionic acid","range":""},{"name":"butyric acid","range":""}],"parameters_zh":[{"name":"乙酸","range":""},{"name":"乳酸","range":""},{"name":"丙酸","range":""},{"name":"丁酸","range":""}],"parameters_cs":[{"name":"Kyselina octová","range":""},{"name":"kyselina mléčná","range":""},{"name":"kyselina propionová","range":""},{"name":"kyselina máselná","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kwasów kiszonkowych metodą izotachoforezy (ITP)\nZakres:\nKwas octowy\nkwas mlekowy\nkwas propionowy\nkwas masłowy","reference":"SOP - 65 (ČSN 46 7092-42)","norm_bases":["SOP - 65","ČSN 46 7092-42"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze, pofermenty z biogazowni Oznaczanie kwasów kiszonkowych metodą izotachoforezy (ITP) Kwas octowy  kwas mlekowy  kwas propionowy  kwas masłowy  Krmiva, digestáty z BPS Stanovení silážních kyselin metodou ITP Kyselina octová  kyselina mléčná  kyselina propionová  kyselina máselná  SOP - 65 (ČSN 46 7092-42) Pasze, pofermenty z biogazowni Oznaczanie kwasow kiszonkowych metoda izotachoforezy (ITP) Kwas octowy  kwas mlekowy  kwas propionowy  kwas maslowy  Krmiva, digestaty z BPS Stanoveni silaznich kyselin metodou ITP Kyselina octova  kyselina mlecna  kyselina propionova  kyselina maselna  SOP - 65 (CSN 46 7092-42)","search_en":"Feedstuffs, digestates from biogas plants Determination of silage acids by ITP method Acetic acid  lactic acid  propionic acid  butyric acid  SOP - 65 (ČSN 46 7092-42)","search_zh":"饲料、沼气站沼渣 等速电泳法测定青贮酸 乙酸  乳酸  丙酸  丁酸  SOP - 65 (ČSN 46 7092-42)","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1f4493b2129aaa174573cde9","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"48","test_object":"Pasze, odchody zwierząt gospodarskich","test_object_en":"Feedstuffs, livestock excrements","test_object_zh":"饲料、畜禽粪便","test_object_cs":"Krmiva, exkrementy hospodářských zvířat","methodology":"Oznaczanie zawartości włókna metodą wagową","methodology_en":"Determination of fibre content by gravimetry","methodology_zh":"重量法测定纤维含量","methodology_cs":"Stanovení obsahu vlákniny gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości włókna metodą wagową","reference":"SOP – 66 (Nařízení komise (ES) č. 152/2009, příloha III, \"I\"; ČSN ISO 6541)","norm_bases":["SOP – 66","Nařízení komise (ES) č. 152/2009","ČSN ISO 6541"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze, odchody zwierząt gospodarskich Oznaczanie zawartości włókna metodą wagową Krmiva, exkrementy hospodářských zvířat Stanovení obsahu vlákniny gravimetricky SOP – 66 (Nařízení komise (ES) č. 152/2009, příloha III, \"I\"; ČSN ISO 6541) Pasze, odchody zwierzat gospodarskich Oznaczanie zawartosci wlokna metoda wagowa Krmiva, exkrementy hospodarskych zvirat Stanoveni obsahu vlakniny gravimetricky SOP – 66 (Narizeni komise (ES) c. 152/2009, priloha III, \"I\"; CSN ISO 6541)","search_en":"Feedstuffs, livestock excrements Determination of fibre content by gravimetry SOP – 66 (Nařízení komise (ES) č. 152/2009, příloha III, \"I\"; ČSN ISO 6541)","search_zh":"饲料、畜禽粪便 重量法测定纤维含量 SOP – 66 (Nařízení komise (ES) č. 152/2009, příloha III, \"I\"; ČSN ISO 6541)","categories":["food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"29a0e0045d9dcb5b909d737c","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"49","test_object":"Pasze, odchody zwierząt gospodarskich","test_object_en":"Feedstuffs, livestock excrements","test_object_zh":"饲料、畜禽粪便","test_object_cs":"Krmiva, exkrementy hospodářských zvířat","methodology":"Oznaczanie zawartości skrobi metodą polarymetryczną","methodology_en":"Determination of starch content by polarimetry","methodology_zh":"旋光法测定淀粉含量","methodology_cs":"Stanovení obsahu škrobu polarimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości skrobi metodą polarymetryczną","reference":"SOP – 67 (Nařízení komise (ES) č. 152/2009, příloha III, \"L\")","norm_bases":["SOP – 67","Nařízení komise (ES) č. 152/2009"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze, odchody zwierząt gospodarskich Oznaczanie zawartości skrobi metodą polarymetryczną Krmiva, exkrementy hospodářských zvířat Stanovení obsahu škrobu polarimetricky SOP – 67 (Nařízení komise (ES) č. 152/2009, příloha III, \"L\") Pasze, odchody zwierzat gospodarskich Oznaczanie zawartosci skrobi metoda polarymetryczna Krmiva, exkrementy hospodarskych zvirat Stanoveni obsahu skrobu polarimetricky SOP – 67 (Narizeni komise (ES) c. 152/2009, priloha III, \"L\")","search_en":"Feedstuffs, livestock excrements Determination of starch content by polarimetry SOP – 67 (Nařízení komise (ES) č. 152/2009, příloha III, \"L\")","search_zh":"饲料、畜禽粪便 旋光法测定淀粉含量 SOP – 67 (Nařízení komise (ES) č. 152/2009, příloha III, \"L\")","categories":["food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"abb4927f41f7c38292d76e1e","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"50","test_object":"Pasze, odchody zwierząt gospodarskich","test_object_en":"Feedstuffs, livestock excrements","test_object_zh":"饲料、畜禽粪便","test_object_cs":"Krmiva, exkrementy hospodářských zvířat","methodology":"Oznaczanie zawartości cukrów metodą miareczkową","methodology_en":"Determination of sugar content by titration","methodology_zh":"滴定法测定糖含量","methodology_cs":"Stanovení obsahu cukrů titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości cukrów metodą miareczkową","reference":"SOP – 68 (Nařízení komise (ES) č. 152/2009, příloha III, \"J\")","norm_bases":["SOP – 68","Nařízení komise (ES) č. 152/2009"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze, odchody zwierząt gospodarskich Oznaczanie zawartości cukrów metodą miareczkową Krmiva, exkrementy hospodářských zvířat Stanovení obsahu cukrů titračně SOP – 68 (Nařízení komise (ES) č. 152/2009, příloha III, \"J\") Pasze, odchody zwierzat gospodarskich Oznaczanie zawartosci cukrow metoda miareczkowa Krmiva, exkrementy hospodarskych zvirat Stanoveni obsahu cukru titracne SOP – 68 (Narizeni komise (ES) c. 152/2009, priloha III, \"J\")","search_en":"Feedstuffs, livestock excrements Determination of sugar content by titration SOP – 68 (Nařízení komise (ES) č. 152/2009, příloha III, \"J\")","search_zh":"饲料、畜禽粪便 滴定法测定糖含量 SOP – 68 (Nařízení komise (ES) č. 152/2009, příloha III, \"J\")","categories":["food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f6603e8b75a53d38157b7f0d","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"51","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie zawartości azotu amonowego metodą spektrofotometryczną i azotu mineralnego obliczeniowo","methodology_en":"Determination of the content of ammonia nitrogen by spectrophotometry and mineral nitrogen by calculation","methodology_zh":"分光光度法测定氨氮含量，计算矿质氮","methodology_cs":"Stanovení obsahu amoniakálního dusíku spektrofotometricky a minerálního dusíku dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu amonowego metodą spektrofotometryczną i azotu mineralnego obliczeniowo","reference":"SOP – 70 (JPP ÚKZÚZ Brno 2011, Analýza půd III)","norm_bases":["SOP – 70","JPP ÚKZÚZ Brno 2011, Analýza půd III"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Materiał pochodzenia roślinnego lub zwierzęcego, żywność, owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy, pasze, nawozy, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, piasek z piaskownic, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Material of plant or animal origin, food, fruit and vegetables, cereal grain, oilseeds, spices, feedstuffs, fertilisers, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, sandpit sand, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"植物或动物源材料、食品、水果和蔬菜、谷物籽粒、油料种子、香料、饲料、肥料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、沙坑沙、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Materiál rostlinného nebo živočišného původu, potraviny, plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření, krmiva, hnojiva, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, písek z pískovišť, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Matryce stałe Oznaczanie zawartości azotu amonowego metodą spektrofotometryczną i azotu mineralnego obliczeniowo Pevné matrice Stanovení obsahu amoniakálního dusíku spektrofotometricky a minerálního dusíku dopočtem SOP – 70 (JPP ÚKZÚZ Brno 2011, Analýza půd III) Matryce stale Oznaczanie zawartosci azotu amonowego metoda spektrofotometryczna i azotu mineralnego obliczeniowo Pevne matrice Stanoveni obsahu amoniakalniho dusiku spektrofotometricky a mineralniho dusiku dopoctem SOP – 70 (JPP UKZUZ Brno 2011, Analyza pud III)","search_en":"Solid matrices Determination of the content of ammonia nitrogen by spectrophotometry and mineral nitrogen by calculation SOP – 70 (JPP ÚKZÚZ Brno 2011, Analýza půd III)","search_zh":"固体基质 分光光度法测定氨氮含量，计算矿质氮 SOP – 70 (JPP ÚKZÚZ Brno 2011, Analýza půd III)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9cb79dbadfa096ea676d8ee4","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"52","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie zawartości azotu azotanowego metodą potencjometryczną","methodology_en":"Determination of the content of nitrate nitrogen by potentiometry","methodology_zh":"电位法测定硝酸盐氮含量","methodology_cs":"Stanovení obsahu dusičnanového dusíku potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu azotanowego metodą potencjometryczną","reference":"SOP - 72 (JPP ÚKZÚZ Brno 2005, Analýza rostlinného materiálu; JPP ÚKZÚZ Brno 2011, Analýza půd III)","norm_bases":["SOP - 72","JPP ÚKZÚZ Brno 2005, Analýza rostlinného materiálu","JPP ÚKZÚZ Brno 2011, Analýza půd III"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Materiał pochodzenia roślinnego lub zwierzęcego, żywność, owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy, pasze, nawozy, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, piasek z piaskownic, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Material of plant or animal origin, food, fruit and vegetables, cereal grain, oilseeds, spices, feedstuffs, fertilisers, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, sandpit sand, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"植物或动物源材料、食品、水果和蔬菜、谷物籽粒、油料种子、香料、饲料、肥料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、沙坑沙、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Materiál rostlinného nebo živočišného původu, potraviny, plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření, krmiva, hnojiva, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, písek z pískovišť, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Matryce stałe Oznaczanie zawartości azotu azotanowego metodą potencjometryczną Pevné matrice Stanovení obsahu dusičnanového dusíku potenciometricky SOP - 72 (JPP ÚKZÚZ Brno 2005, Analýza rostlinného materiálu; JPP ÚKZÚZ Brno 2011, Analýza půd III) Matryce stale Oznaczanie zawartosci azotu azotanowego metoda potencjometryczna Pevne matrice Stanoveni obsahu dusicnanoveho dusiku potenciometricky SOP - 72 (JPP UKZUZ Brno 2005, Analyza rostlinneho materialu; JPP UKZUZ Brno 2011, Analyza pud III)","search_en":"Solid matrices Determination of the content of nitrate nitrogen by potentiometry SOP - 72 (JPP ÚKZÚZ Brno 2005, Analýza rostlinného materiálu; JPP ÚKZÚZ Brno 2011, Analýza půd III)","search_zh":"固体基质 电位法测定硝酸盐氮含量 SOP - 72 (JPP ÚKZÚZ Brno 2005, Analýza rostlinného materiálu; JPP ÚKZÚZ Brno 2011, Analýza půd III)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a2d334f03c724016205d2f53","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"53","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů,","methodology":"Oznaczanie rozpuszczonego węgla organicznego (DOC) i ogólnego węgla organicznego (TOC) metodą spektrometryczną","methodology_en":"Determination of dissolved organic carbon (DOC) and total organic carbon (TOC) by spectrometry","methodology_zh":"光谱法测定溶解性有机碳（DOC）和总有机碳（TOC）","methodology_cs":"Stanovení rozpuštěného organického uhlíku (DOC) a celkového organického uhlíku (TOC) spektrometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rozpuszczonego węgla organicznego (DOC) i ogólnego węgla organicznego (TOC) metodą spektrometryczną","reference":"SOP – 77 (ČSN EN 1484)","norm_bases":["SOP – 77","ČSN EN 1484"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie rozpuszczonego węgla organicznego (DOC) i ogólnego węgla organicznego (TOC) metodą spektrometryczną Vody, vodné výluhy odpadů, Stanovení rozpuštěného organického uhlíku (DOC) a celkového organického uhlíku (TOC) spektrometricky SOP – 77 (ČSN EN 1484) Wody, wyciagi wodne z odpadow Oznaczanie rozpuszczonego wegla organicznego (DOC) i ogolnego wegla organicznego (TOC) metoda spektrometryczna Vody, vodne vyluhy odpadu, Stanoveni rozpusteneho organickeho uhliku (DOC) a celkoveho organickeho uhliku (TOC) spektrometricky SOP – 77 (CSN EN 1484)","search_en":"Water, aqueous extracts of waste Determination of dissolved organic carbon (DOC) and total organic carbon (TOC) by spectrometry SOP – 77 (ČSN EN 1484)","search_zh":"水、废物水浸出液 光谱法测定溶解性有机碳（DOC）和总有机碳（TOC） SOP – 77 (ČSN EN 1484)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"19548bc8dde37b9f1249b7e3","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"54","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie ekstrahowalnych związków chloroorganicznych (EOX) metodą kulometryczną","methodology_en":"Determination of extractable organically bound halogens (EOX) by coulometry","methodology_zh":"库仑法测定可萃取有机卤素（EOX）","methodology_cs":"Stanovení extrahovatelných organicky vázaných halogenů (EOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ekstrahowalnych związków chloroorganicznych (EOX) metodą kulometryczną","reference":"SOP - 78 (DIN 38414-S17)","norm_bases":["SOP - 78","DIN 38414-S17"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Materiał pochodzenia roślinnego lub zwierzęcego, żywność, owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy, pasze, nawozy, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, piasek z piaskownic, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Material of plant or animal origin, food, fruit and vegetables, cereal grain, oilseeds, spices, feedstuffs, fertilisers, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, sandpit sand, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"植物或动物源材料、食品、水果和蔬菜、谷物籽粒、油料种子、香料、饲料、肥料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、沙坑沙、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Materiál rostlinného nebo živočišného původu, potraviny, plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření, krmiva, hnojiva, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, písek z pískovišť, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Matryce stałe Oznaczanie ekstrahowalnych związków chloroorganicznych (EOX) metodą kulometryczną Pevné matrice Stanovení extrahovatelných organicky vázaných halogenů (EOX) coulometricky SOP - 78 (DIN 38414-S17) Matryce stale Oznaczanie ekstrahowalnych zwiazkow chloroorganicznych (EOX) metoda kulometryczna Pevne matrice Stanoveni extrahovatelnych organicky vazanych halogenu (EOX) coulometricky SOP - 78 (DIN 38414-S17)","search_en":"Solid matrices Determination of extractable organically bound halogens (EOX) by coulometry SOP - 78 (DIN 38414-S17)","search_zh":"固体基质 库仑法测定可萃取有机卤素（EOX） SOP - 78 (DIN 38414-S17)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7acdbc371b25e5ec8552ee6c","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"55","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie adsorbowalnych związków chloroorganicznych (AOX) metodą kulometryczną","methodology_en":"Determination of adsorbable organically bound halogens (AOX) by coulometry","methodology_zh":"库仑法测定可吸附有机卤素（AOX）","methodology_cs":"Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie adsorbowalnych związków chloroorganicznych (AOX) metodą kulometryczną","reference":"SOP - 80 (ČSN EN ISO 9562)","norm_bases":["SOP - 80","ČSN EN ISO 9562"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie adsorbowalnych związków chloroorganicznych (AOX) metodą kulometryczną Vody, vodné výluhy odpadů Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky SOP - 80 (ČSN EN ISO 9562) Wody, wyciagi wodne z odpadow Oznaczanie adsorbowalnych zwiazkow chloroorganicznych (AOX) metoda kulometryczna Vody, vodne vyluhy odpadu Stanoveni adsorbovatelnych organicky vazanych halogenu (AOX) coulometricky SOP - 80 (CSN EN ISO 9562)","search_en":"Water, aqueous extracts of waste Determination of adsorbable organically bound halogens (AOX) by coulometry SOP - 80 (ČSN EN ISO 9562)","search_zh":"水、废物水浸出液 库仑法测定可吸附有机卤素（AOX） SOP - 80 (ČSN EN ISO 9562)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b15f6b2b15c4c1108a6b007b","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"56","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie adsorbowalnych związków chloroorganicznych (AOX) metodą kulometryczną","methodology_en":"Determination of adsorbable organically bound halogens (AOX) by coulometry","methodology_zh":"库仑法测定可吸附有机卤素（AOX）","methodology_cs":"Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie adsorbowalnych związków chloroorganicznych (AOX) metodą kulometryczną","reference":"SOP - 80 A (ČSN EN 16166; DIN 38414-S18)","norm_bases":["SOP - 80 A","ČSN EN 16166","DIN 38414-S18"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Materiał pochodzenia roślinnego, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Material of plant origin, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"植物源材料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Materiál rostlinného původu, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Matryce stałe Oznaczanie adsorbowalnych związków chloroorganicznych (AOX) metodą kulometryczną Pevné matrice Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky SOP - 80 A (ČSN EN 16166; DIN 38414-S18) Matryce stale Oznaczanie adsorbowalnych zwiazkow chloroorganicznych (AOX) metoda kulometryczna Pevne matrice Stanoveni adsorbovatelnych organicky vazanych halogenu (AOX) coulometricky SOP - 80 A (CSN EN 16166; DIN 38414-S18)","search_en":"Solid matrices Determination of adsorbable organically bound halogens (AOX) by coulometry SOP - 80 A (ČSN EN 16166; DIN 38414-S18)","search_zh":"固体基质 库仑法测定可吸附有机卤素（AOX） SOP - 80 A (ČSN EN 16166; DIN 38414-S18)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4c3573d31fe547c0b3cb835a","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"57","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie lotnych związków organicznych metodą chromatografii gazowej z detektorem FID, ECD, MS oraz sumy THM i sumy ksylenów obliczeniowo","methodology_en":"Determination of volatile organic compounds by gas chromatography with FID, ECD, MS detector and sum of THM and sum of xylenes by calculation","methodology_zh":"气相色谱（FID、ECD、MS检测）法测定挥发性有机物，计算三卤甲烷和二甲苯总量","methodology_cs":"Stanovení těkavých organických látek metodou plynové chromatografie s detektorem FID, ECD, MS a sumy THM a sumy xylenů dopočtem","parameters":[{"name":"Benzen","range":""},{"name":"toluen","range":""},{"name":"etylobenzen","range":""},{"name":"m-ksylen","range":""},{"name":"o-ksylen","range":""},{"name":"p-ksylen","range":""},{"name":"tetrachlorometan","range":""},{"name":"trichlorometan","range":""},{"name":"bromodichlorometan","range":""},{"name":"dibromochlorometan","range":""},{"name":"1,1-dichloroeten","range":""},{"name":"1,4-dichlorobenzen","range":""},{"name":"1,2-dichloroetan","range":""},{"name":"1,1,1-trichloroetan","range":""},{"name":"trichloroeten","range":""},{"name":"tetrachloroeten","range":""},{"name":"styren","range":""},{"name":"chlorek metylu","range":""},{"name":"trans-1,2-dichloroeten","range":""},{"name":"cis-1,2-dichloroeten","range":""},{"name":"chlorobenzen","range":""},{"name":"bromoform","range":""},{"name":"1,2-dichlorobenzen","range":""},{"name":"1,3-dichlorobenzen","range":""},{"name":"trihalometany","range":""}],"parameters_en":[{"name":"Benzene","range":""},{"name":"toluene","range":""},{"name":"ethylbenzene","range":""},{"name":"m-xylene","range":""},{"name":"o-xylene","range":""},{"name":"p-xylene","range":""},{"name":"tetrachloromethane","range":""},{"name":"trichloromethane","range":""},{"name":"bromodichloromethane","range":""},{"name":"dibromochloromethane","range":""},{"name":"1,1-dichloroethene","range":""},{"name":"1,4-dichlorobenzene","range":""},{"name":"1,2-dichloroethane","range":""},{"name":"1,1,1-trichloroethane","range":""},{"name":"trichloroethene","range":""},{"name":"tetrachloroethene","range":""},{"name":"styrene","range":""},{"name":"methyl chloride","range":""},{"name":"trans-1,2-dichloroethene","range":""},{"name":"cis-1,2-dichloroethene","range":""},{"name":"chlorobenzene","range":""},{"name":"bromoform","range":""},{"name":"1,2-dichlorobenzene","range":""},{"name":"1,3-dichlorobenzene","range":""},{"name":"trihalomethanes","range":""}],"parameters_zh":[{"name":"苯","range":""},{"name":"甲苯","range":""},{"name":"乙苯","range":""},{"name":"间二甲苯","range":""},{"name":"邻二甲苯","range":""},{"name":"对二甲苯","range":""},{"name":"四氯化碳","range":""},{"name":"三氯甲烷","range":""},{"name":"一溴二氯甲烷","range":""},{"name":"二溴一氯甲烷","range":""},{"name":"1,1-二氯乙烯","range":""},{"name":"1,4-二氯苯","range":""},{"name":"1,2-二氯乙烷","range":""},{"name":"1,1,1-三氯乙烷","range":""},{"name":"三氯乙烯","range":""},{"name":"四氯乙烯","range":""},{"name":"苯乙烯","range":""},{"name":"氯甲烷","range":""},{"name":"反-1,2-二氯乙烯","range":""},{"name":"顺-1,2-二氯乙烯","range":""},{"name":"氯苯","range":""},{"name":"三溴甲烷","range":""},{"name":"1,2-二氯苯","range":""},{"name":"1,3-二氯苯","range":""},{"name":"三卤甲烷","range":""}],"parameters_cs":[{"name":"Benzen","range":""},{"name":"toluen","range":""},{"name":"ethylbenzen","range":""},{"name":"m-xylen","range":""},{"name":"o-xylen","range":""},{"name":"p-xylen","range":""},{"name":"tetrachlormethan","range":""},{"name":"trichlormethan","range":""},{"name":"bromdichlormethan","range":""},{"name":"dibromchlormethan","range":""},{"name":"1,1-dichlorethen","range":""},{"name":"1,4-dichlorbenzen","range":""},{"name":"1,2-dichlorethan","range":""},{"name":"1,1,1-trichlorethan","range":""},{"name":"trichlorethen","range":""},{"name":"tetrachlorethen","range":""},{"name":"styren","range":""},{"name":"metylchlorid","range":""},{"name":"trans-1,2-dichlorethen","range":""},{"name":"cis-1,2-dichlorethen","range":""},{"name":"chlorbenzen","range":""},{"name":"bromoform","range":""},{"name":"1,2-dichlorbenzen","range":""},{"name":"1,3-dichlorbenzen","range":""},{"name":"trihalomethany","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma trihalometanów (THM)","suma benzenu, toluenu, etylobenzenu i ksylenów (BTEX)","suma ksylenów"],"computed_en":["sum of trihalomethanes (THM)","sum of benzene, toluene, ethylbenzene and xylenes (BTEX)","sum of xylenes"],"computed_zh":["三卤甲烷总量","苯、甲苯、乙苯和二甲苯总量（BTEX）","二甲苯总量"],"computed_cs":["suma trihalometanů (THM)","suma benzenu+toluenu+ethylbenzenu+ xylenů (BTEX)","suma xylenů"],"activity":"Oznaczanie lotnych związków organicznych metodą chromatografii gazowej z detektorem FID, ECD, MS oraz sumy THM i sumy ksylenów obliczeniowo\nZakres:\nBenzen\ntoluen\netylobenzen\nm-ksylen\no-ksylen\np-ksylen\ntetrachlorometan\ntrichlorometan\nbromodichlorometan\ndibromochlorometan\n1,1-dichloroeten\n1,4-dichlorobenzen\n1,2-dichloroetan\n1,1,1-trichloroetan\ntrichloroeten\ntetrachloroeten\nstyren\nchlorek metylu\ntrans-1,2-dichloroeten\ncis-1,2-dichloroeten\nchlorobenzen\nbromoform\n1,2-dichlorobenzen\n1,3-dichlorobenzen\ntrihalometany","reference":"SOP - 81 (ČSN EN ISO 15680; ČSN EN ISO 10301)","norm_bases":["SOP - 81","ČSN EN ISO 15680","ČSN EN ISO 10301"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun","search_text":"Wody Oznaczanie lotnych związków organicznych metodą chromatografii gazowej z detektorem FID, ECD, MS oraz sumy THM i sumy ksylenów obliczeniowo Benzen  toluen  etylobenzen  m-ksylen  o-ksylen  p-ksylen  tetrachlorometan  trichlorometan  bromodichlorometan  dibromochlorometan  1,1-dichloroeten  1,4-dichlorobenzen  1,2-dichloroetan  1,1,1-trichloroetan  trichloroeten  tetrachloroeten  styren  chlorek metylu  trans-1,2-dichloroeten  cis-1,2-dichloroeten  chlorobenzen  bromoform  1,2-dichlorobenzen  1,3-dichlorobenzen  trihalometany  suma trihalometanów (THM) suma benzenu, toluenu, etylobenzenu i ksylenów (BTEX) suma ksylenów Vody Stanovení těkavých organických látek metodou plynové chromatografie s detektorem FID, ECD, MS a sumy THM a sumy xylenů dopočtem Benzen  toluen  ethylbenzen  m-xylen  o-xylen  p-xylen  tetrachlormethan  trichlormethan  bromdichlormethan  dibromchlormethan  1,1-dichlorethen  1,4-dichlorbenzen  1,2-dichlorethan  1,1,1-trichlorethan  trichlorethen  tetrachlorethen  styren  metylchlorid  trans-1,2-dichlorethen  cis-1,2-dichlorethen  chlorbenzen  bromoform  1,2-dichlorbenzen  1,3-dichlorbenzen  trihalomethany  suma trihalometanů (THM) suma benzenu+toluenu+ethylbenzenu+ xylenů (BTEX) suma xylenů SOP - 81 (ČSN EN ISO 15680; ČSN EN ISO 10301) Wody Oznaczanie lotnych zwiazkow organicznych metoda chromatografii gazowej z detektorem FID, ECD, MS oraz sumy THM i sumy ksylenow obliczeniowo Benzen  toluen  etylobenzen  m-ksylen  o-ksylen  p-ksylen  tetrachlorometan  trichlorometan  bromodichlorometan  dibromochlorometan  1,1-dichloroeten  1,4-dichlorobenzen  1,2-dichloroetan  1,1,1-trichloroetan  trichloroeten  tetrachloroeten  styren  chlorek metylu  trans-1,2-dichloroeten  cis-1,2-dichloroeten  chlorobenzen  bromoform  1,2-dichlorobenzen  1,3-dichlorobenzen  trihalometany  suma trihalometanow (THM) suma benzenu, toluenu, etylobenzenu i ksylenow (BTEX) suma ksylenow Vody Stanoveni tekavych organickych latek metodou plynove chromatografie s detektorem FID, ECD, MS a sumy THM a sumy xylenu dopoctem Benzen  toluen  ethylbenzen  m-xylen  o-xylen  p-xylen  tetrachlormethan  trichlormethan  bromdichlormethan  dibromchlormethan  1,1-dichlorethen  1,4-dichlorbenzen  1,2-dichlorethan  1,1,1-trichlorethan  trichlorethen  tetrachlorethen  styren  metylchlorid  trans-1,2-dichlorethen  cis-1,2-dichlorethen  chlorbenzen  bromoform  1,2-dichlorbenzen  1,3-dichlorbenzen  trihalomethany  suma trihalometanu (THM) suma benzenu+toluenu+ethylbenzenu+ xylenu (BTEX) suma xylenu SOP - 81 (CSN EN ISO 15680; CSN EN ISO 10301)","search_en":"Water Determination of volatile organic compounds by gas chromatography with FID, ECD, MS detector and sum of THM and sum of xylenes by calculation Benzene  toluene  ethylbenzene  m-xylene  o-xylene  p-xylene  tetrachloromethane  trichloromethane  bromodichloromethane  dibromochloromethane  1,1-dichloroethene  1,4-dichlorobenzene  1,2-dichloroethane  1,1,1-trichloroethane  trichloroethene  tetrachloroethene  styrene  methyl chloride  trans-1,2-dichloroethene  cis-1,2-dichloroethene  chlorobenzene  bromoform  1,2-dichlorobenzene  1,3-dichlorobenzene  trihalomethanes  sum of trihalomethanes (THM) sum of benzene, toluene, ethylbenzene and xylenes (BTEX) sum of xylenes SOP - 81 (ČSN EN ISO 15680; ČSN EN ISO 10301)","search_zh":"水 气相色谱（FID、ECD、MS检测）法测定挥发性有机物，计算三卤甲烷和二甲苯总量 苯  甲苯  乙苯  间二甲苯  邻二甲苯  对二甲苯  四氯化碳  三氯甲烷  一溴二氯甲烷  二溴一氯甲烷  1,1-二氯乙烯  1,4-二氯苯  1,2-二氯乙烷  1,1,1-三氯乙烷  三氯乙烯  四氯乙烯  苯乙烯  氯甲烷  反-1,2-二氯乙烯  顺-1,2-二氯乙烯  氯苯  三溴甲烷  1,2-二氯苯  1,3-二氯苯  三卤甲烷  三卤甲烷总量 苯、甲苯、乙苯和二甲苯总量（BTEX） 二甲苯总量 SOP - 81 (ČSN EN ISO 15680; ČSN EN ISO 10301)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"793bf6f9ee3c05b730722f73","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"58","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie lotnych związków organicznych metodą chromatografii gazowej z detektorem FID, ECD, MS oraz sumy BTEX obliczeniowo","methodology_en":"Determination of volatile organic compounds by gas chromatography with FID, ECD, MS detector and sum of BTEX by calculation","methodology_zh":"气相色谱（FID、ECD、MS检测）法测定挥发性有机物，计算BTEX总量","methodology_cs":"Stanovení těkavých organických látek metodou plynové chromatografie s detektorem FID, ECD, MS a sumy BTEX dopočtem","parameters":[{"name":"Benzen","range":""},{"name":"toluen","range":""},{"name":"etylobenzen","range":""},{"name":"m-ksylen","range":""},{"name":"o-ksylen","range":""},{"name":"p-ksylen","range":""},{"name":"tetrachlorometan","range":""},{"name":"trichlorometan","range":""},{"name":"bromodichlorometan","range":""},{"name":"dibromochlorometan","range":""},{"name":"1,1-dichloroeten","range":""},{"name":"1,4-dichlorobenzen","range":""},{"name":"1,2-dichloroetan","range":""},{"name":"1,1,1-trichloroetan","range":""},{"name":"trichloroeten","range":""},{"name":"tetrachloroeten","range":""},{"name":"styren","range":""},{"name":"chlorek metylu","range":""},{"name":"trans-1,2-dichloroeten","range":""},{"name":"cis-1,2-dichloroeten","range":""},{"name":"chlorobenzen","range":""},{"name":"bromoform","range":""},{"name":"1,2-dichlorobenzen","range":""},{"name":"1,3-dichlorobenzen","range":""},{"name":"trihalometany","range":""}],"parameters_en":[{"name":"Benzene","range":""},{"name":"toluene","range":""},{"name":"ethylbenzene","range":""},{"name":"m-xylene","range":""},{"name":"o-xylene","range":""},{"name":"p-xylene","range":""},{"name":"tetrachloromethane","range":""},{"name":"trichloromethane","range":""},{"name":"bromodichloromethane","range":""},{"name":"dibromochloromethane","range":""},{"name":"1,1-dichloroethene","range":""},{"name":"1,4-dichlorobenzene","range":""},{"name":"1,2-dichloroethane","range":""},{"name":"1,1,1-trichloroethane","range":""},{"name":"trichloroethene","range":""},{"name":"tetrachloroethene","range":""},{"name":"styrene","range":""},{"name":"methyl chloride","range":""},{"name":"trans-1,2-dichloroethene","range":""},{"name":"cis-1,2-dichloroethene","range":""},{"name":"chlorobenzene","range":""},{"name":"bromoform","range":""},{"name":"1,2-dichlorobenzene","range":""},{"name":"1,3-dichlorobenzene","range":""},{"name":"trihalomethanes","range":""}],"parameters_zh":[{"name":"苯","range":""},{"name":"甲苯","range":""},{"name":"乙苯","range":""},{"name":"间二甲苯","range":""},{"name":"邻二甲苯","range":""},{"name":"对二甲苯","range":""},{"name":"四氯化碳","range":""},{"name":"三氯甲烷","range":""},{"name":"一溴二氯甲烷","range":""},{"name":"二溴一氯甲烷","range":""},{"name":"1,1-二氯乙烯","range":""},{"name":"1,4-二氯苯","range":""},{"name":"1,2-二氯乙烷","range":""},{"name":"1,1,1-三氯乙烷","range":""},{"name":"三氯乙烯","range":""},{"name":"四氯乙烯","range":""},{"name":"苯乙烯","range":""},{"name":"氯甲烷","range":""},{"name":"反-1,2-二氯乙烯","range":""},{"name":"顺-1,2-二氯乙烯","range":""},{"name":"氯苯","range":""},{"name":"三溴甲烷","range":""},{"name":"1,2-二氯苯","range":""},{"name":"1,3-二氯苯","range":""},{"name":"三卤甲烷","range":""}],"parameters_cs":[{"name":"Benzen","range":""},{"name":"toluen","range":""},{"name":"ethylbenzen","range":""},{"name":"m-xylen","range":""},{"name":"o-xylen","range":""},{"name":"p-xylen","range":""},{"name":"tetrachlormethan","range":""},{"name":"trichlormethan","range":""},{"name":"bromdichlormethan","range":""},{"name":"dibromchlormethan","range":""},{"name":"1,1-dichlorethen","range":""},{"name":"1,4-dichlorbenzen","range":""},{"name":"1,2-dichlorethan","range":""},{"name":"1,1,1-trichlorethan","range":""},{"name":"trichlorethen","range":""},{"name":"tetrachlorethen","range":""},{"name":"styren","range":""},{"name":"metylchlorid","range":""},{"name":"trans-1,2-dichlorethen","range":""},{"name":"cis-1,2-dichlorethen","range":""},{"name":"chlorbenzen","range":""},{"name":"bromoform","range":""},{"name":"1,2-dichlorbenzen","range":""},{"name":"1,3-dichlorbenzen","range":""},{"name":"trihalomethany","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma trihalometanów (THM)","suma benzenu, toluenu, etylobenzenu i ksylenów (BTEX)","suma ksylenów"],"computed_en":["sum of trihalomethanes (THM)","sum of benzene, toluene, ethylbenzene and xylenes (BTEX)","sum of xylenes"],"computed_zh":["三卤甲烷总量","苯、甲苯、乙苯和二甲苯总量（BTEX）","二甲苯总量"],"computed_cs":["suma trihalometanů (THM)","suma benzenu+toluenu+ethylbenzenu+ xylenů (BTEX)","suma xylenů"],"activity":"Oznaczanie lotnych związków organicznych metodą chromatografii gazowej z detektorem FID, ECD, MS oraz sumy BTEX obliczeniowo\nZakres:\nBenzen\ntoluen\netylobenzen\nm-ksylen\no-ksylen\np-ksylen\ntetrachlorometan\ntrichlorometan\nbromodichlorometan\ndibromochlorometan\n1,1-dichloroeten\n1,4-dichlorobenzen\n1,2-dichloroetan\n1,1,1-trichloroetan\ntrichloroeten\ntetrachloroeten\nstyren\nchlorek metylu\ntrans-1,2-dichloroeten\ncis-1,2-dichloroeten\nchlorobenzen\nbromoform\n1,2-dichlorobenzen\n1,3-dichlorobenzen\ntrihalometany","reference":"SOP - 81 A (ČSN EN ISO 15680; ČSN EN ISO 10301)","norm_bases":["SOP - 81 A","ČSN EN ISO 15680","ČSN EN ISO 10301"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Materiał pochodzenia roślinnego, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Material of plant origin, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"植物源材料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Materiál rostlinného původu, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Matryce stałe Oznaczanie lotnych związków organicznych metodą chromatografii gazowej z detektorem FID, ECD, MS oraz sumy BTEX obliczeniowo Benzen  toluen  etylobenzen  m-ksylen  o-ksylen  p-ksylen  tetrachlorometan  trichlorometan  bromodichlorometan  dibromochlorometan  1,1-dichloroeten  1,4-dichlorobenzen  1,2-dichloroetan  1,1,1-trichloroetan  trichloroeten  tetrachloroeten  styren  chlorek metylu  trans-1,2-dichloroeten  cis-1,2-dichloroeten  chlorobenzen  bromoform  1,2-dichlorobenzen  1,3-dichlorobenzen  trihalometany  suma trihalometanów (THM) suma benzenu, toluenu, etylobenzenu i ksylenów (BTEX) suma ksylenów Pevné matrice Stanovení těkavých organických látek metodou plynové chromatografie s detektorem FID, ECD, MS a sumy BTEX dopočtem Benzen  toluen  ethylbenzen  m-xylen  o-xylen  p-xylen  tetrachlormethan  trichlormethan  bromdichlormethan  dibromchlormethan  1,1-dichlorethen  1,4-dichlorbenzen  1,2-dichlorethan  1,1,1-trichlorethan  trichlorethen  tetrachlorethen  styren  metylchlorid  trans-1,2-dichlorethen  cis-1,2-dichlorethen  chlorbenzen  bromoform  1,2-dichlorbenzen  1,3-dichlorbenzen  trihalomethany  suma trihalometanů (THM) suma benzenu+toluenu+ethylbenzenu+ xylenů (BTEX) suma xylenů SOP - 81 A (ČSN EN ISO 15680; ČSN EN ISO 10301) Matryce stale Oznaczanie lotnych zwiazkow organicznych metoda chromatografii gazowej z detektorem FID, ECD, MS oraz sumy BTEX obliczeniowo Benzen  toluen  etylobenzen  m-ksylen  o-ksylen  p-ksylen  tetrachlorometan  trichlorometan  bromodichlorometan  dibromochlorometan  1,1-dichloroeten  1,4-dichlorobenzen  1,2-dichloroetan  1,1,1-trichloroetan  trichloroeten  tetrachloroeten  styren  chlorek metylu  trans-1,2-dichloroeten  cis-1,2-dichloroeten  chlorobenzen  bromoform  1,2-dichlorobenzen  1,3-dichlorobenzen  trihalometany  suma trihalometanow (THM) suma benzenu, toluenu, etylobenzenu i ksylenow (BTEX) suma ksylenow Pevne matrice Stanoveni tekavych organickych latek metodou plynove chromatografie s detektorem FID, ECD, MS a sumy BTEX dopoctem Benzen  toluen  ethylbenzen  m-xylen  o-xylen  p-xylen  tetrachlormethan  trichlormethan  bromdichlormethan  dibromchlormethan  1,1-dichlorethen  1,4-dichlorbenzen  1,2-dichlorethan  1,1,1-trichlorethan  trichlorethen  tetrachlorethen  styren  metylchlorid  trans-1,2-dichlorethen  cis-1,2-dichlorethen  chlorbenzen  bromoform  1,2-dichlorbenzen  1,3-dichlorbenzen  trihalomethany  suma trihalometanu (THM) suma benzenu+toluenu+ethylbenzenu+ xylenu (BTEX) suma xylenu SOP - 81 A (CSN EN ISO 15680; CSN EN ISO 10301)","search_en":"Solid matrices Determination of volatile organic compounds by gas chromatography with FID, ECD, MS detector and sum of BTEX by calculation Benzene  toluene  ethylbenzene  m-xylene  o-xylene  p-xylene  tetrachloromethane  trichloromethane  bromodichloromethane  dibromochloromethane  1,1-dichloroethene  1,4-dichlorobenzene  1,2-dichloroethane  1,1,1-trichloroethane  trichloroethene  tetrachloroethene  styrene  methyl chloride  trans-1,2-dichloroethene  cis-1,2-dichloroethene  chlorobenzene  bromoform  1,2-dichlorobenzene  1,3-dichlorobenzene  trihalomethanes  sum of trihalomethanes (THM) sum of benzene, toluene, ethylbenzene and xylenes (BTEX) sum of xylenes SOP - 81 A (ČSN EN ISO 15680; ČSN EN ISO 10301)","search_zh":"固体基质 气相色谱（FID、ECD、MS检测）法测定挥发性有机物，计算BTEX总量 苯  甲苯  乙苯  间二甲苯  邻二甲苯  对二甲苯  四氯化碳  三氯甲烷  一溴二氯甲烷  二溴一氯甲烷  1,1-二氯乙烯  1,4-二氯苯  1,2-二氯乙烷  1,1,1-三氯乙烷  三氯乙烯  四氯乙烯  苯乙烯  氯甲烷  反-1,2-二氯乙烯  顺-1,2-二氯乙烯  氯苯  三溴甲烷  1,2-二氯苯  1,3-二氯苯  三卤甲烷  三卤甲烷总量 苯、甲苯、乙苯和二甲苯总量（BTEX） 二甲苯总量 SOP - 81 A (ČSN EN ISO 15680; ČSN EN ISO 10301)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2538985a3acff8cf7d3390f4","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"59","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie polichlorowanych bifenyli (PCB) – oznaczanie bezpośrednie metodą GC-ECD i suma PCB obliczeniowo","methodology_en":"Determination of polychlorinated biphenyls (PCB) – direct determination by GC-ECD and sum of PCB by calculation","methodology_zh":"GC-ECD直接测定多氯联苯，计算PCB总量","methodology_cs":"Stanovení polychlorovaných bifenylů (PCB) Přímé stanovení metodou GC-ECD a sumy PCB dopočtem","parameters":[{"name":"Kongener PCB 28","range":""},{"name":"Kongener PCB 52","range":""},{"name":"Kongener PCB 101","range":""},{"name":"Kongener PCB 118","range":""},{"name":"Kongener PCB 153","range":""},{"name":"Kongener PCB 138","range":""},{"name":"Kongener PCB 180","range":""}],"parameters_en":[{"name":"PCB congener 28","range":""},{"name":"PCB congener 52","range":""},{"name":"PCB congener 101","range":""},{"name":"PCB congener 118","range":""},{"name":"PCB congener 153","range":""},{"name":"PCB congener 138","range":""},{"name":"PCB congener 180","range":""}],"parameters_zh":[{"name":"多氯联苯同系物28","range":""},{"name":"多氯联苯同系物52","range":""},{"name":"多氯联苯同系物101","range":""},{"name":"多氯联苯同系物118","range":""},{"name":"多氯联苯同系物153","range":""},{"name":"多氯联苯同系物138","range":""},{"name":"多氯联苯同系物180","range":""}],"parameters_cs":[{"name":"Kongenery PCB 28","range":""},{"name":"Kongenery PCB 52","range":""},{"name":"Kongenery PCB 101","range":""},{"name":"Kongenery PCB 118","range":""},{"name":"Kongenery PCB 153","range":""},{"name":"Kongenery PCB 138","range":""},{"name":"Kongenery PCB 180","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma PCB"],"computed_en":["sum of PCB"],"computed_zh":["PCB总量"],"computed_cs":["suma PCB"],"activity":"Oznaczanie polichlorowanych bifenyli (PCB) – oznaczanie bezpośrednie metodą GC-ECD i suma PCB obliczeniowo\nZakres:\nKongener PCB 28\nKongener PCB 52\nKongener PCB 101\nKongener PCB 118\nKongener PCB 153\nKongener PCB 138\nKongener PCB 180","reference":"SOP - 82 (ČSN EN ISO 6468)","norm_bases":["SOP - 82","ČSN EN ISO 6468"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun","search_text":"Wody Oznaczanie polichlorowanych bifenyli (PCB) – oznaczanie bezpośrednie metodą GC-ECD i suma PCB obliczeniowo Kongener PCB 28  Kongener PCB 52  Kongener PCB 101  Kongener PCB 118  Kongener PCB 153  Kongener PCB 138  Kongener PCB 180  suma PCB Vody Stanovení polychlorovaných bifenylů (PCB) Přímé stanovení metodou GC-ECD a sumy PCB dopočtem Kongenery PCB 28  Kongenery PCB 52  Kongenery PCB 101  Kongenery PCB 118  Kongenery PCB 153  Kongenery PCB 138  Kongenery PCB 180  suma PCB SOP - 82 (ČSN EN ISO 6468) Wody Oznaczanie polichlorowanych bifenyli (PCB) – oznaczanie bezposrednie metoda GC-ECD i suma PCB obliczeniowo Kongener PCB 28  Kongener PCB 52  Kongener PCB 101  Kongener PCB 118  Kongener PCB 153  Kongener PCB 138  Kongener PCB 180  suma PCB Vody Stanoveni polychlorovanych bifenylu (PCB) Prime stanoveni metodou GC-ECD a sumy PCB dopoctem Kongenery PCB 28  Kongenery PCB 52  Kongenery PCB 101  Kongenery PCB 118  Kongenery PCB 153  Kongenery PCB 138  Kongenery PCB 180  suma PCB SOP - 82 (CSN EN ISO 6468)","search_en":"Water Determination of polychlorinated biphenyls (PCB) – direct determination by GC-ECD and sum of PCB by calculation PCB congener 28  PCB congener 52  PCB congener 101  PCB congener 118  PCB congener 153  PCB congener 138  PCB congener 180  sum of PCB SOP - 82 (ČSN EN ISO 6468)","search_zh":"水 GC-ECD直接测定多氯联苯，计算PCB总量 多氯联苯同系物28  多氯联苯同系物52  多氯联苯同系物101  多氯联苯同系物118  多氯联苯同系物153  多氯联苯同系物138  多氯联苯同系物180  PCB总量 SOP - 82 (ČSN EN ISO 6468)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3d36864b05b705587dd24f13","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"60","test_object":"Matryce stałe","test_object_en":"Solid matrices","test_object_zh":"固体基质","test_object_cs":"Pevné matrice","methodology":"Oznaczanie polichlorowanych bifenyli (PCB) – oznaczanie bezpośrednie metodą GC-ECD i suma PCB obliczeniowo","methodology_en":"Determination of polychlorinated biphenyls (PCB) – direct determination by GC-ECD and sum of PCB by calculation","methodology_zh":"GC-ECD直接测定多氯联苯，计算PCB总量","methodology_cs":"Stanovení polychlorovaných bifenylů (PCB) Přímé stanovení metodou GC-ECD a sumy PCB dopočtem","parameters":[{"name":"Kongener PCB 28","range":""},{"name":"Kongener PCB 52","range":""},{"name":"Kongener PCB 101","range":""},{"name":"Kongener PCB 118","range":""},{"name":"Kongener PCB 153","range":""},{"name":"Kongener PCB 138","range":""},{"name":"Kongener PCB 180","range":""}],"parameters_en":[{"name":"PCB congener 28","range":""},{"name":"PCB congener 52","range":""},{"name":"PCB congener 101","range":""},{"name":"PCB congener 118","range":""},{"name":"PCB congener 153","range":""},{"name":"PCB congener 138","range":""},{"name":"PCB congener 180","range":""}],"parameters_zh":[{"name":"多氯联苯同系物28","range":""},{"name":"多氯联苯同系物52","range":""},{"name":"多氯联苯同系物101","range":""},{"name":"多氯联苯同系物118","range":""},{"name":"多氯联苯同系物153","range":""},{"name":"多氯联苯同系物138","range":""},{"name":"多氯联苯同系物180","range":""}],"parameters_cs":[{"name":"Kongenery PCB 28","range":""},{"name":"Kongenery PCB 52","range":""},{"name":"Kongenery PCB 101","range":""},{"name":"Kongenery PCB 118","range":""},{"name":"Kongenery PCB 153","range":""},{"name":"Kongenery PCB 138","range":""},{"name":"Kongenery PCB 180","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma PCB"],"computed_en":["sum of PCB"],"computed_zh":["PCB总量"],"computed_cs":["suma PCB"],"activity":"Oznaczanie polichlorowanych bifenyli (PCB) – oznaczanie bezpośrednie metodą GC-ECD i suma PCB obliczeniowo\nZakres:\nKongener PCB 28\nKongener PCB 52\nKongener PCB 101\nKongener PCB 118\nKongener PCB 153\nKongener PCB 138\nKongener PCB 180","reference":"SOP - 82 A (ČSN EN 17322; ČSN EN 15741)","norm_bases":["SOP - 82 A","ČSN EN 17322","ČSN EN 15741"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Materiał pochodzenia roślinnego, gleby, grunty, gnojowica, obornik, odchody, osady, osady denne, komposty, surowce do kompostów, podłoża, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Material of plant origin, soils, earths, slurry, manure, excrements, sludge, sediments, composts, compost raw materials, substrates, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"植物源材料、土壤、土、粪浆、厩肥、粪便、污泥、沉积物、堆肥、堆肥原料、基质、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Materiál rostlinného původu, půdy, zeminy, kejdy, hnoje, exkrementy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Matryce stałe Oznaczanie polichlorowanych bifenyli (PCB) – oznaczanie bezpośrednie metodą GC-ECD i suma PCB obliczeniowo Kongener PCB 28  Kongener PCB 52  Kongener PCB 101  Kongener PCB 118  Kongener PCB 153  Kongener PCB 138  Kongener PCB 180  suma PCB Pevné matrice Stanovení polychlorovaných bifenylů (PCB) Přímé stanovení metodou GC-ECD a sumy PCB dopočtem Kongenery PCB 28  Kongenery PCB 52  Kongenery PCB 101  Kongenery PCB 118  Kongenery PCB 153  Kongenery PCB 138  Kongenery PCB 180  suma PCB SOP - 82 A (ČSN EN 17322; ČSN EN 15741) Matryce stale Oznaczanie polichlorowanych bifenyli (PCB) – oznaczanie bezposrednie metoda GC-ECD i suma PCB obliczeniowo Kongener PCB 28  Kongener PCB 52  Kongener PCB 101  Kongener PCB 118  Kongener PCB 153  Kongener PCB 138  Kongener PCB 180  suma PCB Pevne matrice Stanoveni polychlorovanych bifenylu (PCB) Prime stanoveni metodou GC-ECD a sumy PCB dopoctem Kongenery PCB 28  Kongenery PCB 52  Kongenery PCB 101  Kongenery PCB 118  Kongenery PCB 153  Kongenery PCB 138  Kongenery PCB 180  suma PCB SOP - 82 A (CSN EN 17322; CSN EN 15741)","search_en":"Solid matrices Determination of polychlorinated biphenyls (PCB) – direct determination by GC-ECD and sum of PCB by calculation PCB congener 28  PCB congener 52  PCB congener 101  PCB congener 118  PCB congener 153  PCB congener 138  PCB congener 180  sum of PCB SOP - 82 A (ČSN EN 17322; ČSN EN 15741)","search_zh":"固体基质 GC-ECD直接测定多氯联苯，计算PCB总量 多氯联苯同系物28  多氯联苯同系物52  多氯联苯同系物101  多氯联苯同系物118  多氯联苯同系物153  多氯联苯同系物138  多氯联苯同系物180  PCB总量 SOP - 82 A (ČSN EN 17322; ČSN EN 15741)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0cfa0246476466ca79d2a18f","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"61","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie pestycydów chloroorganicznych (OCP) metodą GC-ECD i sumy substancji pestycydowych obliczeniowo","methodology_en":"Determination of organochlorinated pesticides (OCP) by GC-ECD and total pesticide substances by calculation","methodology_zh":"GC-ECD法测定有机氯农药，计算农药总量","methodology_cs":"Stanovení organochlorových pesticidů (OCP) metodou GC-ECD a pesticidních látek celkem dopočtem","parameters":[{"name":"Trifluralina","range":""},{"name":"HCB (heksachlorobenzen)","range":""},{"name":"α-HCH","range":""},{"name":"lindan","range":""},{"name":"β-HCH","range":""},{"name":"heptachlor","range":""},{"name":"δ-HCH","range":""},{"name":"aldryna","range":""},{"name":"α-endosulfan","range":""},{"name":"β-endosulfan","range":""},{"name":"p,p'-DDE","range":""},{"name":"p,p'-DDD","range":""},{"name":"p,p'-DDT","range":""},{"name":"dieldryna","range":""},{"name":"endryna","range":""},{"name":"metoksychlor","range":""}],"parameters_en":[{"name":"Trifluralin","range":""},{"name":"HCB (hexachlorobenzene)","range":""},{"name":"α-HCH","range":""},{"name":"lindane","range":""},{"name":"β-HCH","range":""},{"name":"heptachlor","range":""},{"name":"δ-HCH","range":""},{"name":"aldrin","range":""},{"name":"α-endosulfan","range":""},{"name":"β-endosulfan","range":""},{"name":"p,p'-DDE","range":""},{"name":"p,p'-DDD","range":""},{"name":"p,p'-DDT","range":""},{"name":"dieldrin","range":""},{"name":"endrin","range":""},{"name":"methoxychlor","range":""}],"parameters_zh":[{"name":"氟乐灵","range":""},{"name":"六氯苯（HCB）","range":""},{"name":"α-六六六","range":""},{"name":"林丹","range":""},{"name":"β-六六六","range":""},{"name":"七氯","range":""},{"name":"δ-六六六","range":""},{"name":"艾氏剂","range":""},{"name":"α-硫丹","range":""},{"name":"β-硫丹","range":""},{"name":"p,p'-滴滴伊","range":""},{"name":"p,p'-滴滴滴","range":""},{"name":"p,p'-滴滴涕","range":""},{"name":"狄氏剂","range":""},{"name":"异狄氏剂","range":""},{"name":"甲氧滴滴涕","range":""}],"parameters_cs":[{"name":"Trifluralin","range":""},{"name":"HCB","range":""},{"name":"α-HCH","range":""},{"name":"lindan","range":""},{"name":"β-HCH","range":""},{"name":"heptachlor","range":""},{"name":"δ-HCH","range":""},{"name":"aldrin","range":""},{"name":"α-endosulfan","range":""},{"name":"β- endosulfan","range":""},{"name":"p,p’-DDE","range":""},{"name":"p,p‘-DDD","range":""},{"name":"p,p‘-DDT","range":""},{"name":"dieldrin","range":""},{"name":"endrin","range":""},{"name":"methoxychlor","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma substancji pestycydowych (PL)"],"computed_en":["sum of pesticide substances (PL)"],"computed_zh":["农药物质总量（PL）"],"computed_cs":["suma pesticidních látek (PL)"],"activity":"Oznaczanie pestycydów chloroorganicznych (OCP) metodą GC-ECD i sumy substancji pestycydowych obliczeniowo\nZakres:\nTrifluralina\nHCB (heksachlorobenzen)\nα-HCH\nlindan\nβ-HCH\nheptachlor\nδ-HCH\naldryna\nα-endosulfan\nβ-endosulfan\np,p'-DDE\np,p'-DDD\np,p'-DDT\ndieldryna\nendryna\nmetoksychlor","reference":"SOP - 83 (ČSN EN ISO 6468)","norm_bases":["SOP - 83","ČSN EN ISO 6468"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun","search_text":"Wody Oznaczanie pestycydów chloroorganicznych (OCP) metodą GC-ECD i sumy substancji pestycydowych obliczeniowo Trifluralina  HCB (heksachlorobenzen)  α-HCH  lindan  β-HCH  heptachlor  δ-HCH  aldryna  α-endosulfan  β-endosulfan  p,p'-DDE  p,p'-DDD  p,p'-DDT  dieldryna  endryna  metoksychlor  suma substancji pestycydowych (PL) Vody Stanovení organochlorových pesticidů (OCP) metodou GC-ECD a pesticidních látek celkem dopočtem Trifluralin  HCB  α-HCH  lindan  β-HCH  heptachlor  δ-HCH  aldrin  α-endosulfan  β- endosulfan  p,p’-DDE  p,p‘-DDD  p,p‘-DDT  dieldrin  endrin  methoxychlor  suma pesticidních látek (PL) SOP - 83 (ČSN EN ISO 6468) Wody Oznaczanie pestycydow chloroorganicznych (OCP) metoda GC-ECD i sumy substancji pestycydowych obliczeniowo Trifluralina  HCB (heksachlorobenzen)  α-HCH  lindan  β-HCH  heptachlor  δ-HCH  aldryna  α-endosulfan  β-endosulfan  p,p'-DDE  p,p'-DDD  p,p'-DDT  dieldryna  endryna  metoksychlor  suma substancji pestycydowych (PL) Vody Stanoveni organochlorovych pesticidu (OCP) metodou GC-ECD a pesticidnich latek celkem dopoctem Trifluralin  HCB  α-HCH  lindan  β-HCH  heptachlor  δ-HCH  aldrin  α-endosulfan  β- endosulfan  p,p’-DDE  p,p‘-DDD  p,p‘-DDT  dieldrin  endrin  methoxychlor  suma pesticidnich latek (PL) SOP - 83 (CSN EN ISO 6468)","search_en":"Water Determination of organochlorinated pesticides (OCP) by GC-ECD and total pesticide substances by calculation Trifluralin  HCB (hexachlorobenzene)  α-HCH  lindane  β-HCH  heptachlor  δ-HCH  aldrin  α-endosulfan  β-endosulfan  p,p'-DDE  p,p'-DDD  p,p'-DDT  dieldrin  endrin  methoxychlor  sum of pesticide substances (PL) SOP - 83 (ČSN EN ISO 6468)","search_zh":"水 GC-ECD法测定有机氯农药，计算农药总量 氟乐灵  六氯苯（HCB）  α-六六六  林丹  β-六六六  七氯  δ-六六六  艾氏剂  α-硫丹  β-硫丹  p,p'-滴滴伊  p,p'-滴滴滴  p,p'-滴滴涕  狄氏剂  异狄氏剂  甲氧滴滴涕  农药物质总量（PL） SOP - 83 (ČSN EN ISO 6468)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5ffbf29526281f7894d1bd36","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"62","test_object":"Gleby, osady denne, osady (szlamy)","test_object_en":"Soils, sediments, sludge","test_object_zh":"土壤、沉积物、污泥","test_object_cs":"Půdy, sedimenty, kaly","methodology":"Oznaczanie pestycydów chloroorganicznych (OCP) metodą GC-ECD","methodology_en":"Determination of organochlorinated pesticides (OCP) by GC-ECD","methodology_zh":"GC-ECD法测定有机氯农药","methodology_cs":"Stanovení organochlorových pesticidů (OCP) metodou GC-ECD","parameters":[{"name":"Trifluralina","range":""},{"name":"HCB (heksachlorobenzen)","range":""},{"name":"α-HCH","range":""},{"name":"lindan","range":""},{"name":"β-HCH","range":""},{"name":"heptachlor","range":""},{"name":"δ-HCH","range":""},{"name":"aldryna","range":""},{"name":"α-endosulfan","range":""},{"name":"β-endosulfan","range":""},{"name":"p,p'-DDE","range":""},{"name":"p,p'-DDD","range":""},{"name":"p,p'-DDT","range":""},{"name":"dieldryna","range":""},{"name":"endryna","range":""},{"name":"metoksychlor","range":""}],"parameters_en":[{"name":"Trifluralin","range":""},{"name":"HCB (hexachlorobenzene)","range":""},{"name":"α-HCH","range":""},{"name":"lindane","range":""},{"name":"β-HCH","range":""},{"name":"heptachlor","range":""},{"name":"δ-HCH","range":""},{"name":"aldrin","range":""},{"name":"α-endosulfan","range":""},{"name":"β-endosulfan","range":""},{"name":"p,p'-DDE","range":""},{"name":"p,p'-DDD","range":""},{"name":"p,p'-DDT","range":""},{"name":"dieldrin","range":""},{"name":"endrin","range":""},{"name":"methoxychlor","range":""}],"parameters_zh":[{"name":"氟乐灵","range":""},{"name":"六氯苯（HCB）","range":""},{"name":"α-六六六","range":""},{"name":"林丹","range":""},{"name":"β-六六六","range":""},{"name":"七氯","range":""},{"name":"δ-六六六","range":""},{"name":"艾氏剂","range":""},{"name":"α-硫丹","range":""},{"name":"β-硫丹","range":""},{"name":"p,p'-滴滴伊","range":""},{"name":"p,p'-滴滴滴","range":""},{"name":"p,p'-滴滴涕","range":""},{"name":"狄氏剂","range":""},{"name":"异狄氏剂","range":""},{"name":"甲氧滴滴涕","range":""}],"parameters_cs":[{"name":"Trifluralin","range":""},{"name":"HCB","range":""},{"name":"α-HCH","range":""},{"name":"lindan","range":""},{"name":"β-HCH","range":""},{"name":"heptachlor","range":""},{"name":"δ-HCH","range":""},{"name":"aldrin","range":""},{"name":"α-endosulfan","range":""},{"name":"β- endosulfan","range":""},{"name":"p,p’-DDE","range":""},{"name":"p,p‘-DDD","range":""},{"name":"p,p‘-DDT","range":""},{"name":"dieldrin","range":""},{"name":"endrin","range":""},{"name":"methoxychlor","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma substancji pestycydowych (PL)"],"computed_en":["sum of pesticide substances (PL)"],"computed_zh":["农药物质总量（PL）"],"computed_cs":["suma pesticidních látek (PL)"],"activity":"Oznaczanie pestycydów chloroorganicznych (OCP) metodą GC-ECD\nZakres:\nTrifluralina\nHCB (heksachlorobenzen)\nα-HCH\nlindan\nβ-HCH\nheptachlor\nδ-HCH\naldryna\nα-endosulfan\nβ-endosulfan\np,p'-DDE\np,p'-DDD\np,p'-DDT\ndieldryna\nendryna\nmetoksychlor","reference":"SOP - 83 A (ČSN EN 15741; EPA Method 608; EPA Method 3550; EPA 3620)","norm_bases":["SOP - 83 A","ČSN EN 15741","EPA Method 608","EPA Method 3550","EPA 3620"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady denne, osady (szlamy) Oznaczanie pestycydów chloroorganicznych (OCP) metodą GC-ECD Trifluralina  HCB (heksachlorobenzen)  α-HCH  lindan  β-HCH  heptachlor  δ-HCH  aldryna  α-endosulfan  β-endosulfan  p,p'-DDE  p,p'-DDD  p,p'-DDT  dieldryna  endryna  metoksychlor  suma substancji pestycydowych (PL) Půdy, sedimenty, kaly Stanovení organochlorových pesticidů (OCP) metodou GC-ECD Trifluralin  HCB  α-HCH  lindan  β-HCH  heptachlor  δ-HCH  aldrin  α-endosulfan  β- endosulfan  p,p’-DDE  p,p‘-DDD  p,p‘-DDT  dieldrin  endrin  methoxychlor  suma pesticidních látek (PL) SOP - 83 A (ČSN EN 15741; EPA Method 608; EPA Method 3550; EPA 3620) Gleby, osady denne, osady (szlamy) Oznaczanie pestycydow chloroorganicznych (OCP) metoda GC-ECD Trifluralina  HCB (heksachlorobenzen)  α-HCH  lindan  β-HCH  heptachlor  δ-HCH  aldryna  α-endosulfan  β-endosulfan  p,p'-DDE  p,p'-DDD  p,p'-DDT  dieldryna  endryna  metoksychlor  suma substancji pestycydowych (PL) Pudy, sedimenty, kaly Stanoveni organochlorovych pesticidu (OCP) metodou GC-ECD Trifluralin  HCB  α-HCH  lindan  β-HCH  heptachlor  δ-HCH  aldrin  α-endosulfan  β- endosulfan  p,p’-DDE  p,p‘-DDD  p,p‘-DDT  dieldrin  endrin  methoxychlor  suma pesticidnich latek (PL) SOP - 83 A (CSN EN 15741; EPA Method 608; EPA Method 3550; EPA 3620)","search_en":"Soils, sediments, sludge Determination of organochlorinated pesticides (OCP) by GC-ECD Trifluralin  HCB (hexachlorobenzene)  α-HCH  lindane  β-HCH  heptachlor  δ-HCH  aldrin  α-endosulfan  β-endosulfan  p,p'-DDE  p,p'-DDD  p,p'-DDT  dieldrin  endrin  methoxychlor  sum of pesticide substances (PL) SOP - 83 A (ČSN EN 15741; EPA Method 608; EPA Method 3550; EPA 3620)","search_zh":"土壤、沉积物、污泥 GC-ECD法测定有机氯农药 氟乐灵  六氯苯（HCB）  α-六六六  林丹  β-六六六  七氯  δ-六六六  艾氏剂  α-硫丹  β-硫丹  p,p'-滴滴伊  p,p'-滴滴滴  p,p'-滴滴涕  狄氏剂  异狄氏剂  甲氧滴滴涕  农药物质总量（PL） SOP - 83 A (ČSN EN 15741; EPA Method 608; EPA Method 3550; EPA 3620)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cbd2e92a3aa39e023882768c","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"63","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie herbicydów triazynowych metodą GC-NPD","methodology_en":"Determination of triazine herbicides by GC-NPD method","methodology_zh":"GC-NPD法测定三嗪类除草剂","methodology_cs":"Stanovení triazinových herbicidů metodou GC-NPD","parameters":[{"name":"Desetyloatrazyna","range":""},{"name":"atrazyna","range":""},{"name":"symazyna","range":""},{"name":"terbutyloazyna","range":""},{"name":"sebutyloazyna","range":""},{"name":"prometryna","range":""},{"name":"terbutryna","range":""},{"name":"cyjanazyna","range":""},{"name":"metazachlor","range":""},{"name":"atrazyna-desizopropyl","range":""}],"parameters_en":[{"name":"Desethylatrazine","range":""},{"name":"atrazine","range":""},{"name":"simazine","range":""},{"name":"terbuthylazine","range":""},{"name":"sebuthylazine","range":""},{"name":"prometryn","range":""},{"name":"terbutryn","range":""},{"name":"cyanazine","range":""},{"name":"metazachlor","range":""},{"name":"atrazine-desisopropyl","range":""}],"parameters_zh":[{"name":"脱乙基莠去津","range":""},{"name":"莠去津","range":""},{"name":"西玛津","range":""},{"name":"特丁津","range":""},{"name":"另丁津","range":""},{"name":"扑草净","range":""},{"name":"特丁净","range":""},{"name":"氰草津","range":""},{"name":"吡唑草胺","range":""},{"name":"脱异丙基莠去津","range":""}],"parameters_cs":[{"name":"Desethylatrazin","range":""},{"name":"atrazin","range":""},{"name":"simazin","range":""},{"name":"terbuthylazin","range":""},{"name":"sebuthylazin","range":""},{"name":"prometryn","range":""},{"name":"terbutryn","range":""},{"name":"cyanazin","range":""},{"name":"metazachlor","range":""},{"name":"atrazine-desizopropyl","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie herbicydów triazynowych metodą GC-NPD\nZakres:\nDesetyloatrazyna\natrazyna\nsymazyna\nterbutyloazyna\nsebutyloazyna\nprometryna\nterbutryna\ncyjanazyna\nmetazachlor\natrazyna-desizopropyl","reference":"SOP - 84 (ČSN EN ISO 10695)","norm_bases":["SOP - 84","ČSN EN ISO 10695"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun","search_text":"Wody Oznaczanie herbicydów triazynowych metodą GC-NPD Desetyloatrazyna  atrazyna  symazyna  terbutyloazyna  sebutyloazyna  prometryna  terbutryna  cyjanazyna  metazachlor  atrazyna-desizopropyl  Vody Stanovení triazinových herbicidů metodou GC-NPD Desethylatrazin  atrazin  simazin  terbuthylazin  sebuthylazin  prometryn  terbutryn  cyanazin  metazachlor  atrazine-desizopropyl  SOP - 84 (ČSN EN ISO 10695) Wody Oznaczanie herbicydow triazynowych metoda GC-NPD Desetyloatrazyna  atrazyna  symazyna  terbutyloazyna  sebutyloazyna  prometryna  terbutryna  cyjanazyna  metazachlor  atrazyna-desizopropyl  Vody Stanoveni triazinovych herbicidu metodou GC-NPD Desethylatrazin  atrazin  simazin  terbuthylazin  sebuthylazin  prometryn  terbutryn  cyanazin  metazachlor  atrazine-desizopropyl  SOP - 84 (CSN EN ISO 10695)","search_en":"Water Determination of triazine herbicides by GC-NPD method Desethylatrazine  atrazine  simazine  terbuthylazine  sebuthylazine  prometryn  terbutryn  cyanazine  metazachlor  atrazine-desisopropyl  SOP - 84 (ČSN EN ISO 10695)","search_zh":"水 GC-NPD法测定三嗪类除草剂 脱乙基莠去津  莠去津  西玛津  特丁津  另丁津  扑草净  特丁净  氰草津  吡唑草胺  脱异丙基莠去津  SOP - 84 (ČSN EN ISO 10695)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"393db265c2858c6892169f20","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"64","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie sumy węglowodorów C10 – C40 metodą GC-FID","methodology_en":"Determination of the sum of hydrocarbons C10 – C40 by GC-FID","methodology_zh":"GC-FID法测定C10-C40烃总量","methodology_cs":"Stanovení sumy uhlovodíků C10 – C40 metodou GC-FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie sumy węglowodorów C10 – C40 metodą GC-FID","reference":"SOP - 85 (ČSN EN ISO 9377-2)","norm_bases":["SOP - 85","ČSN EN ISO 9377-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun","search_text":"Wody Oznaczanie sumy węglowodorów C10 – C40 metodą GC-FID Vody Stanovení sumy uhlovodíků C10 – C40 metodou GC-FID SOP - 85 (ČSN EN ISO 9377-2) Wody Oznaczanie sumy weglowodorow C10 – C40 metoda GC-FID Vody Stanoveni sumy uhlovodiku C10 – C40 metodou GC-FID SOP - 85 (CSN EN ISO 9377-2)","search_en":"Water Determination of the sum of hydrocarbons C10 – C40 by GC-FID SOP - 85 (ČSN EN ISO 9377-2)","search_zh":"水 GC-FID法测定C10-C40烃总量 SOP - 85 (ČSN EN ISO 9377-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ffb56e1ade281c68ae4a1210","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"65","test_object":"Gleby, osady denne, osady (szlamy) i odpady","test_object_en":"Soils, sludge, sediments and waste","test_object_zh":"土壤、沉积物、污泥和废物","test_object_cs":"Půdy, sedimenty, kaly a odpady","methodology":"Oznaczanie sumy węglowodorów C10 – C40 metodą GC-FID","methodology_en":"Determination of the sum of hydrocarbons C10 – C40 by GC-FID","methodology_zh":"GC-FID法测定C10-C40烃总量","methodology_cs":"Stanovení sumy uhlovodíků C10 – C40 metodou GC-FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie sumy węglowodorów C10 – C40 metodą GC-FID","reference":"SOP - 85 A (ČSN EN 14039)","norm_bases":["SOP - 85 A","ČSN EN 14039"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Gleby, grunty, osady, osady denne, komposty, surowce do kompostów, podłoża, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane, mieszanki bitumiczne i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Soils, earths, sludge, sediments, composts, compost raw materials, substrates, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste, asphalt mixtures and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"土壤、土、污泥、沉积物、堆肥、堆肥原料、基质、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物、沥青混合料及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Půdy, zeminy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady, asfaltové směsi a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Gleby, osady denne, osady (szlamy) i odpady Oznaczanie sumy węglowodorów C10 – C40 metodą GC-FID Půdy, sedimenty, kaly a odpady Stanovení sumy uhlovodíků C10 – C40 metodou GC-FID SOP - 85 A (ČSN EN 14039) Gleby, osady denne, osady (szlamy) i odpady Oznaczanie sumy weglowodorow C10 – C40 metoda GC-FID Pudy, sedimenty, kaly a odpady Stanoveni sumy uhlovodiku C10 – C40 metodou GC-FID SOP - 85 A (CSN EN 14039)","search_en":"Soils, sludge, sediments and waste Determination of the sum of hydrocarbons C10 – C40 by GC-FID SOP - 85 A (ČSN EN 14039)","search_zh":"土壤、沉积物、污泥和废物 GC-FID法测定C10-C40烃总量 SOP - 85 A (ČSN EN 14039)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9ce202b8efaa4f3f942b7900","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"66","test_object":"Wody, wyciągi wodne z odpadów","test_object_en":"Water, aqueous extracts of waste","test_object_zh":"水、废物水浸出液","test_object_cs":"Vody, vodné výluhy odpadů","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą HPLC z detekcją fluorescencyjną i suma WWA obliczeniowo","methodology_en":"Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detection and sum of PAH by calculation","methodology_zh":"HPLC-荧光检测法测定多环芳烃，计算PAH总量","methodology_cs":"Stanovení polycyklických aromatických uhlovodíků (PAU) metodou HPLC s fluorescenční detekcí a sumy PAU dopočtem","parameters":[{"name":"Fluoranten","range":""},{"name":"antracen","range":""},{"name":"benzo(a)antracen","range":""},{"name":"dibenz(a,b)antracen","range":""},{"name":"chryzen","range":""},{"name":"piren","range":""},{"name":"benzo(a)piren","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"benzo(g,h,i)perylen","range":""},{"name":"indeno(1,2,3-c,d)piren","range":""},{"name":"acenaften","range":""},{"name":"acenaftylen","range":""},{"name":"fluoren","range":""},{"name":"naftalen","range":""},{"name":"fenantren","range":""}],"parameters_en":[{"name":"Fluoranthene","range":""},{"name":"anthracene","range":""},{"name":"benzo(a)anthracene","range":""},{"name":"dibenz(a,b)anthracene","range":""},{"name":"chrysene","range":""},{"name":"pyrene","range":""},{"name":"benzo(a)pyrene","range":""},{"name":"benzo(b)fluoranthene","range":""},{"name":"benzo(k)fluoranthene","range":""},{"name":"benzo(g,h,i)perylene","range":""},{"name":"indeno(1,2,3-c,d)pyrene","range":""},{"name":"acenaphthene","range":""},{"name":"acenaphthylene","range":""},{"name":"fluorene","range":""},{"name":"naphthalene","range":""},{"name":"phenanthrene","range":""}],"parameters_zh":[{"name":"荧蒽","range":""},{"name":"蒽","range":""},{"name":"苯并(a)蒽","range":""},{"name":"二苯并(a,b)蒽","range":""},{"name":"䓛","range":""},{"name":"芘","range":""},{"name":"苯并(a)芘","range":""},{"name":"苯并(b)荧蒽","range":""},{"name":"苯并(k)荧蒽","range":""},{"name":"苯并(g,h,i)苝","range":""},{"name":"茚并(1,2,3-c,d)芘","range":""},{"name":"苊","range":""},{"name":"苊烯","range":""},{"name":"芴","range":""},{"name":"萘","range":""},{"name":"菲","range":""}],"parameters_cs":[{"name":"Fluoranthen","range":""},{"name":"anthracen","range":""},{"name":"benzo(a)anthracen","range":""},{"name":"dibenz(a,b)anthracen","range":""},{"name":"chrysen","range":""},{"name":"pyren","range":""},{"name":"benzo(a)pyren","range":""},{"name":"benzo(b)fluoranthen","range":""},{"name":"benzo(k)fluoranthen","range":""},{"name":"benzo(g,h,i )perylen","range":""},{"name":"indeno(1,2,3-c,d)pyren","range":""},{"name":"acenaften","range":""},{"name":"acenaftylen","range":""},{"name":"fluoren","range":""},{"name":"naftalen","range":""},{"name":"fenanthren","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma WWA"],"computed_en":["sum of PAH"],"computed_zh":["PAH总量"],"computed_cs":["suma PAU"],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą HPLC z detekcją fluorescencyjną i suma WWA obliczeniowo\nZakres:\nFluoranten\nantracen\nbenzo(a)antracen\ndibenz(a,b)antracen\nchryzen\npiren\nbenzo(a)piren\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(g,h,i)perylen\nindeno(1,2,3-c,d)piren\nacenaften\nacenaftylen\nfluoren\nnaftalen\nfenantren","reference":"SOP - 91 (ČSN 75 7554:1998; ČSN EN ISO 17993)","norm_bases":["SOP - 91","ČSN 75 7554:1998","ČSN EN ISO 17993"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Wody przeznaczone do spożycia, surowe, uzdatnione i przygotowane; podziemne, źródlane, powierzchniowe, ciepła woda użytkowa, odcieki i ścieki, wody butelkowane, woda z automatów z napojami, woda z kąpielisk, basenów i saun | Wyciągi wodne z odpadów obojętnych, ulegających biodegradacji, ciekłych, komunalnych, osadów z oczyszczalni ścieków, odpadów kompostowalnych, urobku ziemnego, odpadów zmieszanych i innych materiałów zaliczonych do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Drinking, raw, processed and treated; ground, spring, surface, domestic hot water, leachate and waste water, bottled water, water from drinks dispensers, water from bathing places, swimming pools and saunas | Aqueous extracts of inert, biodegradable, liquid and municipal waste, sewage sludge, compostable waste, excavated soil, mixed waste and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"饮用水、原水、成品水和处理水；地下水、泉水、地表水、生活热水、渗滤液和废水、瓶装水、饮料机用水、游泳场所、泳池和桑拿用水 | 惰性废物、可生物降解废物、液态废物、城市废物、污水处理厂污泥、可堆肥废物、开挖土、混合废物及按第273/2021号法令（现行版本）归类为废物的其他材料的水浸出液","note_cs":"Pitné, surové, vyrobené a upravené; podzemní, pramenité, povrchové, teplé užitkové vody, průsakové a odpadní vody, balené vody, vody z nápojových automatů, vody z koupališť, bazénů a saun | Vodné výluhy inertních odpadů, biologicky rozložitelných odpadů, kapalných odpadů, komunálních odpadů, kalů z ČOV, kompostovatelných odpadů, výkopových zemin, směsných odpadů a ostatních materiálů zařazených jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Wody, wyciągi wodne z odpadów Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą HPLC z detekcją fluorescencyjną i suma WWA obliczeniowo Fluoranten  antracen  benzo(a)antracen  dibenz(a,b)antracen  chryzen  piren  benzo(a)piren  benzo(b)fluoranten  benzo(k)fluoranten  benzo(g,h,i)perylen  indeno(1,2,3-c,d)piren  acenaften  acenaftylen  fluoren  naftalen  fenantren  suma WWA Vody, vodné výluhy odpadů Stanovení polycyklických aromatických uhlovodíků (PAU) metodou HPLC s fluorescenční detekcí a sumy PAU dopočtem Fluoranthen  anthracen  benzo(a)anthracen  dibenz(a,b)anthracen  chrysen  pyren  benzo(a)pyren  benzo(b)fluoranthen  benzo(k)fluoranthen  benzo(g,h,i )perylen  indeno(1,2,3-c,d)pyren  acenaften  acenaftylen  fluoren  naftalen  fenanthren  suma PAU SOP - 91 (ČSN 75 7554:1998; ČSN EN ISO 17993) Wody, wyciagi wodne z odpadow Oznaczanie wielopierscieniowych weglowodorow aromatycznych (WWA) metoda HPLC z detekcja fluorescencyjna i suma WWA obliczeniowo Fluoranten  antracen  benzo(a)antracen  dibenz(a,b)antracen  chryzen  piren  benzo(a)piren  benzo(b)fluoranten  benzo(k)fluoranten  benzo(g,h,i)perylen  indeno(1,2,3-c,d)piren  acenaften  acenaftylen  fluoren  naftalen  fenantren  suma WWA Vody, vodne vyluhy odpadu Stanoveni polycyklickych aromatickych uhlovodiku (PAU) metodou HPLC s fluorescencni detekci a sumy PAU dopoctem Fluoranthen  anthracen  benzo(a)anthracen  dibenz(a,b)anthracen  chrysen  pyren  benzo(a)pyren  benzo(b)fluoranthen  benzo(k)fluoranthen  benzo(g,h,i )perylen  indeno(1,2,3-c,d)pyren  acenaften  acenaftylen  fluoren  naftalen  fenanthren  suma PAU SOP - 91 (CSN 75 7554:1998; CSN EN ISO 17993)","search_en":"Water, aqueous extracts of waste Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detection and sum of PAH by calculation Fluoranthene  anthracene  benzo(a)anthracene  dibenz(a,b)anthracene  chrysene  pyrene  benzo(a)pyrene  benzo(b)fluoranthene  benzo(k)fluoranthene  benzo(g,h,i)perylene  indeno(1,2,3-c,d)pyrene  acenaphthene  acenaphthylene  fluorene  naphthalene  phenanthrene  sum of PAH SOP - 91 (ČSN 75 7554:1998; ČSN EN ISO 17993)","search_zh":"水、废物水浸出液 HPLC-荧光检测法测定多环芳烃，计算PAH总量 荧蒽  蒽  苯并(a)蒽  二苯并(a,b)蒽  䓛  芘  苯并(a)芘  苯并(b)荧蒽  苯并(k)荧蒽  苯并(g,h,i)苝  茚并(1,2,3-c,d)芘  苊  苊烯  芴  萘  菲  PAH总量 SOP - 91 (ČSN 75 7554:1998; ČSN EN ISO 17993)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3084c4f52490539e8fa55a50","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"67","test_object":"Gleby, osady denne, osady (szlamy) i odpady","test_object_en":"Soils, sludge, sediments and waste","test_object_zh":"土壤、沉积物、污泥和废物","test_object_cs":"Půdy, sedimenty, kaly a odpady","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą HPLC z detekcją fluorescencyjną i suma WWA obliczeniowo","methodology_en":"Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detection and sum of PAH by calculation","methodology_zh":"HPLC-荧光检测法测定多环芳烃，计算PAH总量","methodology_cs":"Stanovení polycyklických aromatických uhlovodíků (PAU) metodou HPLC s fluorescenční detekcí a sumy PAU dopočtem","parameters":[{"name":"Fluoranten","range":""},{"name":"antracen","range":""},{"name":"benzo(a)antracen","range":""},{"name":"dibenz(a,b)antracen","range":""},{"name":"chryzen","range":""},{"name":"piren","range":""},{"name":"benzo(a)piren","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"benzo(g,h,i)perylen","range":""},{"name":"indeno(1,2,3-c,d)piren","range":""},{"name":"acenaften","range":""},{"name":"acenaftylen","range":""},{"name":"fluoren","range":""},{"name":"naftalen","range":""},{"name":"fenantren","range":""}],"parameters_en":[{"name":"Fluoranthene","range":""},{"name":"anthracene","range":""},{"name":"benzo(a)anthracene","range":""},{"name":"dibenz(a,b)anthracene","range":""},{"name":"chrysene","range":""},{"name":"pyrene","range":""},{"name":"benzo(a)pyrene","range":""},{"name":"benzo(b)fluoranthene","range":""},{"name":"benzo(k)fluoranthene","range":""},{"name":"benzo(g,h,i)perylene","range":""},{"name":"indeno(1,2,3-c,d)pyrene","range":""},{"name":"acenaphthene","range":""},{"name":"acenaphthylene","range":""},{"name":"fluorene","range":""},{"name":"naphthalene","range":""},{"name":"phenanthrene","range":""}],"parameters_zh":[{"name":"荧蒽","range":""},{"name":"蒽","range":""},{"name":"苯并(a)蒽","range":""},{"name":"二苯并(a,b)蒽","range":""},{"name":"䓛","range":""},{"name":"芘","range":""},{"name":"苯并(a)芘","range":""},{"name":"苯并(b)荧蒽","range":""},{"name":"苯并(k)荧蒽","range":""},{"name":"苯并(g,h,i)苝","range":""},{"name":"茚并(1,2,3-c,d)芘","range":""},{"name":"苊","range":""},{"name":"苊烯","range":""},{"name":"芴","range":""},{"name":"萘","range":""},{"name":"菲","range":""}],"parameters_cs":[{"name":"Fluoranthen","range":""},{"name":"anthracen","range":""},{"name":"benzo(a)anthracen","range":""},{"name":"dibenz(a,b)anthracen","range":""},{"name":"chrysen","range":""},{"name":"pyren","range":""},{"name":"benzo(a)pyren","range":""},{"name":"benzo(b)fluoranthen","range":""},{"name":"benzo(k)fluoranthen","range":""},{"name":"benzo(g,h,i )perylen","range":""},{"name":"indeno(1,2,3-c,d)pyren","range":""},{"name":"acenaften","range":""},{"name":"acenaftylen","range":""},{"name":"fluoren","range":""},{"name":"naftalen","range":""},{"name":"fenanthren","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma WWA"],"computed_en":["sum of PAH"],"computed_zh":["PAH总量"],"computed_cs":["suma PAU"],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą HPLC z detekcją fluorescencyjną i suma WWA obliczeniowo\nZakres:\nFluoranten\nantracen\nbenzo(a)antracen\ndibenz(a,b)antracen\nchryzen\npiren\nbenzo(a)piren\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(g,h,i)perylen\nindeno(1,2,3-c,d)piren\nacenaften\nacenaftylen\nfluoren\nnaftalen\nfenantren","reference":"SOP - 91 A (ČSN EN 17503; TNV 75 8055:2004; JPP ÚKZÚZ Brno 2011, Analýza půd II)","norm_bases":["SOP - 91 A","ČSN EN 17503","TNV 75 8055:2004","JPP ÚKZÚZ Brno 2011, Analýza půd II"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Gleby, grunty, osady, osady denne, komposty, surowce do kompostów, podłoża, odpady obojętne, ulegające biodegradacji, ciekłe, komunalne, kompostowalne, urobek ziemny, odpady zmieszane, mieszanki bitumiczne i inne materiały zaliczone do odpadów zgodnie z rozporządzeniem nr 273/2021 Sb. w obowiązującym brzmieniu","note_en":"Soils, earths, sludge, sediments, composts, compost raw materials, substrates, inert, biodegradable, liquid, municipal and compostable waste, excavated soil, mixed waste, asphalt mixtures and other materials classified as waste under Decree No. 273/2021 Coll., as amended","note_zh":"土壤、土、污泥、沉积物、堆肥、堆肥原料、基质、惰性废物、可生物降解废物、液态废物、城市废物、可堆肥废物、开挖土、混合废物、沥青混合料及按第273/2021号法令（现行版本）归类为废物的其他材料","note_cs":"Půdy, zeminy, kaly, sedimenty, komposty, suroviny do kompostů, substráty, inertní odpady, biologicky rozložitelné odpady, kapalné odpady, komunální odpady, kompostovatelné odpady, výkopové zeminy, směsné odpady, asfaltové směsi a ostatní materiály zařazené jako odpad v souladu s vyhláškou č. 273/2021 Sb. v platném znění","search_text":"Gleby, osady denne, osady (szlamy) i odpady Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą HPLC z detekcją fluorescencyjną i suma WWA obliczeniowo Fluoranten  antracen  benzo(a)antracen  dibenz(a,b)antracen  chryzen  piren  benzo(a)piren  benzo(b)fluoranten  benzo(k)fluoranten  benzo(g,h,i)perylen  indeno(1,2,3-c,d)piren  acenaften  acenaftylen  fluoren  naftalen  fenantren  suma WWA Půdy, sedimenty, kaly a odpady Stanovení polycyklických aromatických uhlovodíků (PAU) metodou HPLC s fluorescenční detekcí a sumy PAU dopočtem Fluoranthen  anthracen  benzo(a)anthracen  dibenz(a,b)anthracen  chrysen  pyren  benzo(a)pyren  benzo(b)fluoranthen  benzo(k)fluoranthen  benzo(g,h,i )perylen  indeno(1,2,3-c,d)pyren  acenaften  acenaftylen  fluoren  naftalen  fenanthren  suma PAU SOP - 91 A (ČSN EN 17503; TNV 75 8055:2004; JPP ÚKZÚZ Brno 2011, Analýza půd II) Gleby, osady denne, osady (szlamy) i odpady Oznaczanie wielopierscieniowych weglowodorow aromatycznych (WWA) metoda HPLC z detekcja fluorescencyjna i suma WWA obliczeniowo Fluoranten  antracen  benzo(a)antracen  dibenz(a,b)antracen  chryzen  piren  benzo(a)piren  benzo(b)fluoranten  benzo(k)fluoranten  benzo(g,h,i)perylen  indeno(1,2,3-c,d)piren  acenaften  acenaftylen  fluoren  naftalen  fenantren  suma WWA Pudy, sedimenty, kaly a odpady Stanoveni polycyklickych aromatickych uhlovodiku (PAU) metodou HPLC s fluorescencni detekci a sumy PAU dopoctem Fluoranthen  anthracen  benzo(a)anthracen  dibenz(a,b)anthracen  chrysen  pyren  benzo(a)pyren  benzo(b)fluoranthen  benzo(k)fluoranthen  benzo(g,h,i )perylen  indeno(1,2,3-c,d)pyren  acenaften  acenaftylen  fluoren  naftalen  fenanthren  suma PAU SOP - 91 A (CSN EN 17503; TNV 75 8055:2004; JPP UKZUZ Brno 2011, Analyza pud II)","search_en":"Soils, sludge, sediments and waste Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detection and sum of PAH by calculation Fluoranthene  anthracene  benzo(a)anthracene  dibenz(a,b)anthracene  chrysene  pyrene  benzo(a)pyrene  benzo(b)fluoranthene  benzo(k)fluoranthene  benzo(g,h,i)perylene  indeno(1,2,3-c,d)pyrene  acenaphthene  acenaphthylene  fluorene  naphthalene  phenanthrene  sum of PAH SOP - 91 A (ČSN EN 17503; TNV 75 8055:2004; JPP ÚKZÚZ Brno 2011, Analýza půd II)","search_zh":"土壤、沉积物、污泥和废物 HPLC-荧光检测法测定多环芳烃，计算PAH总量 荧蒽  蒽  苯并(a)蒽  二苯并(a,b)蒽  䓛  芘  苯并(a)芘  苯并(b)荧蒽  苯并(k)荧蒽  苯并(g,h,i)苝  茚并(1,2,3-c,d)芘  苊  苊烯  芴  萘  菲  PAH总量 SOP - 91 A (ČSN EN 17503; TNV 75 8055:2004; JPP ÚKZÚZ Brno 2011, Analýza půd II)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8e7fdea91d8310716eec43be","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"68","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie pestycydów i farmaceutyków metodą LC/MS/MS (tryb negatywny i pozytywny) oraz ich sumy obliczeniowo z wartości zmierzonych","methodology_en":"Determination of pesticides and pharmaceuticals by LC/MS/MS (negative and positive mode) and their sums by calculation from measured values","methodology_zh":"LC/MS/MS法（负离子和正离子模式）测定农药和药物，由测量值计算总量","methodology_cs":"Stanovení pesticidů a farmak metodou LC/MS/MS (negativní a pozitivní mode) a jejich sumy dopočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pestycydów i farmaceutyków metodą LC/MS/MS (tryb negatywny i pozytywny) oraz ich sumy obliczeniowo z wartości zmierzonych","reference":"SOP - 100 (EPA Method 1694)","norm_bases":["SOP - 100","EPA Method 1694"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Woda przeznaczona do spożycia, podziemna, surowa i powierzchniowa | Oznaczane substancje (nazwy zwyczajowe jak w oryginale): 1,2,4-triazol, 2,6-dichlorbenzamid, acetochlor, acetochlor ESA, acetochlor OA, alachlor, alachlor ESA, alachlor OA, atrazin, atrazin 2‐hydroxy, atrazin desethyl, atrazin desethyl-desisopropyl, atrazin desisopropyl, azoxystrobin, azoxystrobin o‐demethyl, bentazon, boskalid, carbendazim, desmetryn, diflufenikan, dimethachlor, dimethachlor CGA 369873, dimethachlor ESA, dimethachlor OA, dimethenamid, dimethenamid ESA, dimethenamid OA, dimoxystrobin, epoxikonazol, ethofumesate, ETU (ethylenthiomočovina), fluazifop-P, flufenacet ESA, hexazinon, chloridazon, chloridazon desphenyl, chloridazon methyl-desphenyl, chlorothalonil R417888, chlorothalonil R471811, chlorotoluron, chlorotoluron desmethyl, imazamox, isoproturon, isoproturon monodesmethyl, lenacil, MCPA, MCPP, metamitron, metazachlor, metazachlor ESA, metazachlor OA, methoxyfenozid, metolachlor, metolachlor ESA, metolachlor OA, metribuzin, metribuzin desamino, metribuzin desaminodiketo, metribuzin diketo, nicosulfuron, pethoxamid, pethoxamid ESA picloram, prometryn, propachlor ESA, propikonazol,, quinmerac, simazin, simazin 2-hydroxy, terbuthylazin, terbuthylazin 2-hydroxy, terbuthylazin desethyl, terbutryn, thiamethoxam, 2,4,5-T, ametryn, bisfenol A, bromoxynil, clopyralid, clomazone, cyanazin, diazinon, dimethoat, chlorfenvinphos, metalaxyl, prometon, propachlor, propazin, quizalofop-P, sebutylazin, simetryn, tebuconazole","note_en":"Drinking, ground, raw and surface water | Determined substances (common names as in the original): 1,2,4-triazol, 2,6-dichlorbenzamid, acetochlor, acetochlor ESA, acetochlor OA, alachlor, alachlor ESA, alachlor OA, atrazin, atrazin 2‐hydroxy, atrazin desethyl, atrazin desethyl-desisopropyl, atrazin desisopropyl, azoxystrobin, azoxystrobin o‐demethyl, bentazon, boskalid, carbendazim, desmetryn, diflufenikan, dimethachlor, dimethachlor CGA 369873, dimethachlor ESA, dimethachlor OA, dimethenamid, dimethenamid ESA, dimethenamid OA, dimoxystrobin, epoxikonazol, ethofumesate, ETU (ethylenthiomočovina), fluazifop-P, flufenacet ESA, hexazinon, chloridazon, chloridazon desphenyl, chloridazon methyl-desphenyl, chlorothalonil R417888, chlorothalonil R471811, chlorotoluron, chlorotoluron desmethyl, imazamox, isoproturon, isoproturon monodesmethyl, lenacil, MCPA, MCPP, metamitron, metazachlor, metazachlor ESA, metazachlor OA, methoxyfenozid, metolachlor, metolachlor ESA, metolachlor OA, metribuzin, metribuzin desamino, metribuzin desaminodiketo, metribuzin diketo, nicosulfuron, pethoxamid, pethoxamid ESA picloram, prometryn, propachlor ESA, propikonazol,, quinmerac, simazin, simazin 2-hydroxy, terbuthylazin, terbuthylazin 2-hydroxy, terbuthylazin desethyl, terbutryn, thiamethoxam, 2,4,5-T, ametryn, bisfenol A, bromoxynil, clopyralid, clomazone, cyanazin, diazinon, dimethoat, chlorfenvinphos, metalaxyl, prometon, propachlor, propazin, quizalofop-P, sebutylazin, simetryn, tebuconazole","note_zh":"饮用水、地下水、原水和地表水 | 测定物质（通用名称，同原文）：1,2,4-triazol, 2,6-dichlorbenzamid, acetochlor, acetochlor ESA, acetochlor OA, alachlor, alachlor ESA, alachlor OA, atrazin, atrazin 2‐hydroxy, atrazin desethyl, atrazin desethyl-desisopropyl, atrazin desisopropyl, azoxystrobin, azoxystrobin o‐demethyl, bentazon, boskalid, carbendazim, desmetryn, diflufenikan, dimethachlor, dimethachlor CGA 369873, dimethachlor ESA, dimethachlor OA, dimethenamid, dimethenamid ESA, dimethenamid OA, dimoxystrobin, epoxikonazol, ethofumesate, ETU (ethylenthiomočovina), fluazifop-P, flufenacet ESA, hexazinon, chloridazon, chloridazon desphenyl, chloridazon methyl-desphenyl, chlorothalonil R417888, chlorothalonil R471811, chlorotoluron, chlorotoluron desmethyl, imazamox, isoproturon, isoproturon monodesmethyl, lenacil, MCPA, MCPP, metamitron, metazachlor, metazachlor ESA, metazachlor OA, methoxyfenozid, metolachlor, metolachlor ESA, metolachlor OA, metribuzin, metribuzin desamino, metribuzin desaminodiketo, metribuzin diketo, nicosulfuron, pethoxamid, pethoxamid ESA picloram, prometryn, propachlor ESA, propikonazol,, quinmerac, simazin, simazin 2-hydroxy, terbuthylazin, terbuthylazin 2-hydroxy, terbuthylazin desethyl, terbutryn, thiamethoxam, 2,4,5-T, ametryn, bisfenol A, bromoxynil, clopyralid, clomazone, cyanazin, diazinon, dimethoat, chlorfenvinphos, metalaxyl, prometon, propachlor, propazin, quizalofop-P, sebutylazin, simetryn, tebuconazole","note_cs":"Voda pitná, podzemní, surová a povrchová | 1,2,4-triazol, 2,6-dichlorbenzamid, acetochlor, acetochlor ESA, acetochlor OA, alachlor, alachlor ESA, alachlor OA, atrazin, atrazin 2‐hydroxy, atrazin desethyl, atrazin desethyl-desisopropyl, atrazin desisopropyl, azoxystrobin, azoxystrobin o‐demethyl, bentazon, boskalid, carbendazim, desmetryn, diflufenikan, dimethachlor, dimethachlor CGA 369873, dimethachlor ESA, dimethachlor OA, dimethenamid, dimethenamid ESA, dimethenamid OA, dimoxystrobin, epoxikonazol, ethofumesate, ETU (ethylenthiomočovina), fluazifop-P, flufenacet ESA, hexazinon, chloridazon, chloridazon desphenyl, chloridazon methyl-desphenyl, chlorothalonil R417888, chlorothalonil R471811, chlorotoluron, chlorotoluron desmethyl, imazamox, isoproturon, isoproturon monodesmethyl, lenacil, MCPA, MCPP, metamitron, metazachlor, metazachlor ESA, metazachlor OA, methoxyfenozid, metolachlor, metolachlor ESA, metolachlor OA, metribuzin, metribuzin desamino, metribuzin desaminodiketo, metribuzin diketo, nicosulfuron, pethoxamid, pethoxamid ESA picloram, prometryn, propachlor ESA, propikonazol,, quinmerac, simazin, simazin 2-hydroxy, terbuthylazin, terbuthylazin 2-hydroxy, terbuthylazin desethyl, terbutryn, thiamethoxam, 2,4,5-T, ametryn, bisfenol A, bromoxynil, clopyralid, clomazone, cyanazin, diazinon, dimethoat, chlorfenvinphos, metalaxyl, prometon, propachlor, propazin, quizalofop-P, sebutylazin, simetryn, tebuconazole","search_text":"Wody Oznaczanie pestycydów i farmaceutyków metodą LC/MS/MS (tryb negatywny i pozytywny) oraz ich sumy obliczeniowo z wartości zmierzonych Vody Stanovení pesticidů a farmak metodou LC/MS/MS (negativní a pozitivní mode) a jejich sumy dopočtem z naměřených hodnot SOP - 100 (EPA Method 1694) Wody Oznaczanie pestycydow i farmaceutykow metoda LC/MS/MS (tryb negatywny i pozytywny) oraz ich sumy obliczeniowo z wartosci zmierzonych Vody Stanoveni pesticidu a farmak metodou LC/MS/MS (negativni a pozitivni mode) a jejich sumy dopoctem z namerenych hodnot SOP - 100 (EPA Method 1694)","search_en":"Water Determination of pesticides and pharmaceuticals by LC/MS/MS (negative and positive mode) and their sums by calculation from measured values SOP - 100 (EPA Method 1694)","search_zh":"水 LC/MS/MS法（负离子和正离子模式）测定农药和药物，由测量值计算总量 SOP - 100 (EPA Method 1694)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6a33755fe1e4d683d7da9a16","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"69","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie glifosatu i pestycydów polarnych metodą IC/MS/MS oraz ich sumy obliczeniowo z wartości zmierzonych","methodology_en":"Determination of glyphosate and polar pesticides by IC/MS/MS and their sums by calculation from measured values","methodology_zh":"IC/MS/MS法测定草甘膦和极性农药，由测量值计算总量","methodology_cs":"Stanovení glyfosátu a polárních pesticidů metodou IC/MS/MS a jejich sumy dopočtem z naměřených hodnot","parameters":[{"name":"Glifosat","range":""},{"name":"AMPA","range":""},{"name":"Chlopyralid","range":""},{"name":"Dikamba","range":""},{"name":"Glufosynat","range":""}],"parameters_en":[{"name":"Glyphosate","range":""},{"name":"AMPA","range":""},{"name":"Clopyralid","range":""},{"name":"Dicamba","range":""},{"name":"Glyphosinate","range":""}],"parameters_zh":[{"name":"草甘膦","range":""},{"name":"氨甲基膦酸（AMPA）","range":""},{"name":"二氯吡啶酸","range":""},{"name":"麦草畏","range":""},{"name":"草铵膦","range":""}],"parameters_cs":[{"name":"Glyfosát","range":""},{"name":"AMPA","range":""},{"name":"Clopyralid","range":""},{"name":"Dicamba","range":""},{"name":"Glyfosinát","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie glifosatu i pestycydów polarnych metodą IC/MS/MS oraz ich sumy obliczeniowo z wartości zmierzonych\nZakres:\nGlifosat\nAMPA\nChlopyralid\nDikamba\nGlufosynat","reference":"SOP - 101 (Thermo Fischer Scientific, Application Note 666)","norm_bases":["SOP - 101","Thermo Fischer Scientific, Application Note 666"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Woda przeznaczona do spożycia, podziemna, surowa i powierzchniowa | Publikacja fachowa – Application Note 666: rutynowa analiza pestycydów polarnych w wodzie na niskich poziomach metodą chromatografii jonowej sprzężonej z potrójnym kwadrupolowym spektrometrem mas – nota aplikacyjna Thermo Fisher Scientific","note_en":"Drinking, ground, raw and surface water | Specialized publication – Application Note 666: Routine analysis of polar pesticides in water at low mg/l levels by ion chromatography coupled to triple quadrupole mass spectrometr – Thermo Fisher Scientific application note","note_zh":"饮用水、地下水、原水和地表水 | 专业出版物——应用说明666：离子色谱-三重四极杆质谱法常规分析水中低浓度极性农药——赛默飞世尔应用说明","note_cs":"Voda pitná, podzemní, surová a povrchová | Odborná publikace – Application Note 666: Routine analysis of polar pesticides in water at low mg/l levels by ion chromatography coupled to triple quadrupole mass spectrometr – Thermo Fisher Scientific application note","search_text":"Wody Oznaczanie glifosatu i pestycydów polarnych metodą IC/MS/MS oraz ich sumy obliczeniowo z wartości zmierzonych Glifosat  AMPA  Chlopyralid  Dikamba  Glufosynat  Vody Stanovení glyfosátu a polárních pesticidů metodou IC/MS/MS a jejich sumy dopočtem z naměřených hodnot Glyfosát  AMPA  Clopyralid  Dicamba  Glyfosinát  SOP - 101 (Thermo Fischer Scientific, Application Note 666) Wody Oznaczanie glifosatu i pestycydow polarnych metoda IC/MS/MS oraz ich sumy obliczeniowo z wartosci zmierzonych Glifosat  AMPA  Chlopyralid  Dikamba  Glufosynat  Vody Stanoveni glyfosatu a polarnich pesticidu metodou IC/MS/MS a jejich sumy dopoctem z namerenych hodnot Glyfosat  AMPA  Clopyralid  Dicamba  Glyfosinat  SOP - 101 (Thermo Fischer Scientific, Application Note 666)","search_en":"Water Determination of glyphosate and polar pesticides by IC/MS/MS and their sums by calculation from measured values Glyphosate  AMPA  Clopyralid  Dicamba  Glyphosinate  SOP - 101 (Thermo Fischer Scientific, Application Note 666)","search_zh":"水 IC/MS/MS法测定草甘膦和极性农药，由测量值计算总量 草甘膦  氨甲基膦酸（AMPA）  二氯吡啶酸  麦草畏  草铵膦  SOP - 101 (Thermo Fischer Scientific, Application Note 666)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6c2a31e27a4930eaa83706d1","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"70","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie wodzianu chloralu metodą GC/ECD","methodology_en":"Determination of chloral hydrate by GC/ECD","methodology_zh":"GC/ECD法测定水合氯醛","methodology_cs":"Stanovení chloral hydrátu metodou GC/ECD","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wodzianu chloralu metodą GC/ECD","reference":"SOP - 102 (EPA Method 551.1)","norm_bases":["SOP - 102","EPA Method 551.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Woda przeznaczona do spożycia, podziemna, surowa, powierzchniowa oraz woda z kąpielisk i basenów","note_en":"Drinking, ground, raw, surface water and water from bathing places and swimming pools","note_zh":"饮用水、地下水、原水、地表水及游泳场所和泳池用水","note_cs":"Voda pitná, podzemní, surová, povrchová a voda z koupališť a bazénů","search_text":"Wody Oznaczanie wodzianu chloralu metodą GC/ECD Vody Stanovení chloral hydrátu metodou GC/ECD SOP - 102 (EPA Method 551.1) Wody Oznaczanie wodzianu chloralu metoda GC/ECD Vody Stanoveni chloral hydratu metodou GC/ECD SOP - 102 (EPA Method 551.1)","search_en":"Water Determination of chloral hydrate by GC/ECD SOP - 102 (EPA Method 551.1)","search_zh":"水 GC/ECD法测定水合氯醛 SOP - 102 (EPA Method 551.1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c81ba0d7cd338d1b8b6bba17","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"71","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie kwasów halogenooctowych metodą IC/MS/MS oraz ich sumy obliczeniowo z wartości zmierzonych","methodology_en":"Determination of haloacetic acids by IC/MS/MS method and their sums by calculation from measured values","methodology_zh":"IC/MS/MS法测定卤乙酸，由测量值计算总量","methodology_cs":"Stanovení halogenoctových kyselin metodou IC/MS/MS a jejich sumy dopočtem z naměřených hodnot","parameters":[{"name":"Kwas dichlorooctowy","range":""},{"name":"kwas dibromooctowy","range":""},{"name":"kwas monobromooctowy","range":""},{"name":"kwas monochlorooctowy","range":""},{"name":"kwas trichlorooctowy","range":""}],"parameters_en":[{"name":"Dichloroacetic acid","range":""},{"name":"dibromoacetic acid","range":""},{"name":"monobromoacetic acid","range":""},{"name":"monochloroacetic acid","range":""},{"name":"trichloroacetic acid","range":""}],"parameters_zh":[{"name":"二氯乙酸","range":""},{"name":"二溴乙酸","range":""},{"name":"一溴乙酸","range":""},{"name":"一氯乙酸","range":""},{"name":"三氯乙酸","range":""}],"parameters_cs":[{"name":"Kyselina dichloroctová","range":""},{"name":"kyselina dibromoctová","range":""},{"name":"kyselina monobromoctová","range":""},{"name":"kyselina monochloroctová","range":""},{"name":"kyselina trichloroctová","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kwasów halogenooctowych metodą IC/MS/MS oraz ich sumy obliczeniowo z wartości zmierzonych\nZakres:\nKwas dichlorooctowy\nkwas dibromooctowy\nkwas monobromooctowy\nkwas monochlorooctowy\nkwas trichlorooctowy","reference":"SOP 103 (EPA Method 557.2)","norm_bases":["SOP 103","EPA Method 557.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Woda przeznaczona do spożycia, podziemna, surowa i powierzchniowa","note_en":"Drinking, ground, raw and surface water","note_zh":"饮用水、地下水、原水和地表水","note_cs":"Voda pitná, podzemní, surová a povrchová","search_text":"Wody Oznaczanie kwasów halogenooctowych metodą IC/MS/MS oraz ich sumy obliczeniowo z wartości zmierzonych Kwas dichlorooctowy  kwas dibromooctowy  kwas monobromooctowy  kwas monochlorooctowy  kwas trichlorooctowy  Vody Stanovení halogenoctových kyselin metodou IC/MS/MS a jejich sumy dopočtem z naměřených hodnot Kyselina dichloroctová  kyselina dibromoctová  kyselina monobromoctová  kyselina monochloroctová  kyselina trichloroctová  SOP 103 (EPA Method 557.2) Wody Oznaczanie kwasow halogenooctowych metoda IC/MS/MS oraz ich sumy obliczeniowo z wartosci zmierzonych Kwas dichlorooctowy  kwas dibromooctowy  kwas monobromooctowy  kwas monochlorooctowy  kwas trichlorooctowy  Vody Stanoveni halogenoctovych kyselin metodou IC/MS/MS a jejich sumy dopoctem z namerenych hodnot Kyselina dichloroctova  kyselina dibromoctova  kyselina monobromoctova  kyselina monochloroctova  kyselina trichloroctova  SOP 103 (EPA Method 557.2)","search_en":"Water Determination of haloacetic acids by IC/MS/MS method and their sums by calculation from measured values Dichloroacetic acid  dibromoacetic acid  monobromoacetic acid  monochloroacetic acid  trichloroacetic acid  SOP 103 (EPA Method 557.2)","search_zh":"水 IC/MS/MS法测定卤乙酸，由测量值计算总量 二氯乙酸  二溴乙酸  一溴乙酸  一氯乙酸  三氯乙酸  SOP 103 (EPA Method 557.2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0eeb6322b3a5129d1739dba3","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"72","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie alkilofenoli metodą LC/MS/MS","methodology_en":"Determination of alkylphenols by LC/MS/MS method","methodology_zh":"LC/MS/MS法测定烷基酚","methodology_cs":"Stanovení alkylfenolů metodou LC/MS/MS","parameters":[{"name":"Bisfenol A","range":""}],"parameters_en":[{"name":"Bisphenol A","range":""}],"parameters_zh":[{"name":"双酚A","range":""}],"parameters_cs":[{"name":"Bisfenol A","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie alkilofenoli metodą LC/MS/MS\nBisfenol A","reference":"SOP 104 (ELGA-VEOLIA application note)","norm_bases":["SOP 104","ELGA-VEOLIA application note"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Woda przeznaczona do spożycia, podziemna, surowa i powierzchniowa | Publikacja fachowa – Application Note: woda ultraczysta niezbędna do bezpośredniego oznaczania bisfenolu A metodą HPLC/MS/MS – nota aplikacyjna ELGA-VEOLIA","note_en":"Drinking, ground, raw and surface water | Specialized publication – Application Note: Ultrapure water essencial for direct determination of bisphenol A by HPLC/MS/MS – ELGA-VEOLIA application note","note_zh":"饮用水、地下水、原水和地表水 | 专业出版物——应用说明：HPLC/MS/MS直接测定双酚A所需的超纯水——ELGA-VEOLIA应用说明","note_cs":"Voda pitná, podzemní, surová a povrchová | Odborná publikace – Application Note: Ultrapure water essencial for direct determination of bisphenol A by HPLC/MS/MS – ELGA-VEOLIA application note","search_text":"Wody Oznaczanie alkilofenoli metodą LC/MS/MS Bisfenol A  Vody Stanovení alkylfenolů metodou LC/MS/MS Bisfenol A  SOP 104 (ELGA-VEOLIA application note) Wody Oznaczanie alkilofenoli metoda LC/MS/MS Bisfenol A  Vody Stanoveni alkylfenolu metodou LC/MS/MS Bisfenol A  SOP 104 (ELGA-VEOLIA application note)","search_en":"Water Determination of alkylphenols by LC/MS/MS method Bisphenol A  SOP 104 (ELGA-VEOLIA application note)","search_zh":"水 LC/MS/MS法测定烷基酚 双酚A  SOP 104 (ELGA-VEOLIA application note)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9b3f8e8db5275ed2a43419e3","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"73","test_object":"Wody","test_object_en":"Water","test_object_zh":"水","test_object_cs":"Vody","methodology":"Oznaczanie związków per- i polifluoroalkilowych (PFAS) metodą LC/MS/MS oraz ich sumy obliczeniowo z wartości zmierzonych","methodology_en":"Determination of per- and poly-fluorinated alkyl substances (PFAS) by LC/MS/MS method and their sum by calculation from measured values","methodology_zh":"LC/MS/MS法测定全氟和多氟烷基化合物（PFAS），由测量值计算总量","methodology_cs":"Stanovení per- a polyfluorovaných alkylových sloučenin (PFAS) metodou LC/MS/MS a jejich sumy dopočtem z naměřených hodnot","parameters":[{"name":"Kwas perfluorobutanowy (PFBA)","range":""},{"name":"Kwas perfluoropentanowy (PFPeA)","range":""},{"name":"Kwas perfluoroheksanowy (PFHxA)","range":""},{"name":"Kwas perfluoroheptanowy (PFHpA)","range":""},{"name":"Kwas perfluorooktanowy (PFOA)","range":""},{"name":"Kwas perfluorononanowy (PFNA)","range":""},{"name":"Kwas perfluorodekanowy (PFDA)","range":""},{"name":"Kwas perfluoroundekanowy (PFUnDA)","range":""},{"name":"Kwas perfluorododekanowy (PFDoDA)","range":""},{"name":"Kwas perfluorotridekanowy (PFTrDA)","range":""},{"name":"Kwas perfluorobutanosulfonowy (PFBS)","range":""},{"name":"Kwas perfluoropentanosulfonowy (PFPeS)","range":""},{"name":"Kwas perfluoroheksanosulfonowy (PFHxS)","range":""},{"name":"Kwas perfluoroheptanosulfonowy (PFHpS)","range":""},{"name":"Kwas perfluorooktanosulfonowy (PFOS)","range":""},{"name":"Kwas perfluorononanosulfonowy (PFNS)","range":""},{"name":"Kwas perfluorodekanosulfonowy (PFDS)","range":""},{"name":"Kwas perfluoroundekanosulfonowy (PFUnDS)","range":""},{"name":"Kwas perfluorododekanosulfonowy (PFDoDS)","range":""},{"name":"Kwas perfluorotridekanosulfonowy (PFTrDS)","range":""}],"parameters_en":[{"name":"perfluorobutanoic acid (PFBA)","range":""},{"name":"perfluoropentanoic acid (PFPeA)","range":""},{"name":"perfluorohexanoic acid (PFHxA)","range":""},{"name":"perfluoroheptanoic acid (PFHpA)","range":""},{"name":"perfluorooctanoic acid (PFOA)","range":""},{"name":"perfluorononanoic acid (PFNA)","range":""},{"name":"perfluorodecanoic acid (PFDA)","range":""},{"name":"perfluoroundecanoic acid (PFUnDA)","range":""},{"name":"perfluorododecanoic acid (PFDoDA)","range":""},{"name":"perfluorotridecanoic acid (PFTrDA)","range":""},{"name":"perfluorobutanesulfonic acid (PFBS)","range":""},{"name":"perfluoropentanesulfonic acid (PFPeS)","range":""},{"name":"perfluorohexanesulfonic acid (PFHxS)","range":""},{"name":"perfluoroheptanesulfonic acid (PFHpS)","range":""},{"name":"perfluorooctanesulfonic acid (PFOS)","range":""},{"name":"perfluorononanesulfonic acid (PFNS)","range":""},{"name":"perfluorodecanesulfonic acid (PFDS)","range":""},{"name":"perfluoroundecanesulfonic acid (PFUnDS)","range":""},{"name":"perfluorododecanesulfonic acid (PFDoDS)","range":""},{"name":"perfluorotridecanesulfonic acid (PFTrDS)","range":""}],"parameters_zh":[{"name":"全氟丁酸（PFBA）","range":""},{"name":"全氟戊酸（PFPeA）","range":""},{"name":"全氟己酸（PFHxA）","range":""},{"name":"全氟庚酸（PFHpA）","range":""},{"name":"全氟辛酸（PFOA）","range":""},{"name":"全氟壬酸（PFNA）","range":""},{"name":"全氟癸酸（PFDA）","range":""},{"name":"全氟十一酸（PFUnDA）","range":""},{"name":"全氟十二酸（PFDoDA）","range":""},{"name":"全氟十三酸（PFTrDA）","range":""},{"name":"全氟丁烷磺酸（PFBS）","range":""},{"name":"全氟戊烷磺酸（PFPeS）","range":""},{"name":"全氟己烷磺酸（PFHxS）","range":""},{"name":"全氟庚烷磺酸（PFHpS）","range":""},{"name":"全氟辛烷磺酸（PFOS）","range":""},{"name":"全氟壬烷磺酸（PFNS）","range":""},{"name":"全氟癸烷磺酸（PFDS）","range":""},{"name":"全氟十一烷磺酸（PFUnDS）","range":""},{"name":"全氟十二烷磺酸（PFDoDS）","range":""},{"name":"全氟十三烷磺酸（PFTrDS）","range":""}],"parameters_cs":[{"name":"perfluorobutanová kyselina (PFBA)","range":""},{"name":"perfluoropentanová kyselina (PFPeA)","range":""},{"name":"perfluorohexanová kyselina (PFHxA)","range":""},{"name":"perfluoroheptanová kyselina (PFHpA)","range":""},{"name":"perfluoroktanová kyselina (PFOA)","range":""},{"name":"perfluorononanová kyselina (PFNA)","range":""},{"name":"perfluorodekanová kyselina (PFDA)","range":""},{"name":"perfluoroundekanová kyselina (PFUnDA)","range":""},{"name":"perflurododekanová kyselina (PFDoDA)","range":""},{"name":"perflurotridekanová kyselina (PFTrDA)","range":""},{"name":"perfluorobutansulfonová kyselina (PFBS)","range":""},{"name":"perfluoropentansulfonová kyselina (PFPeS)","range":""},{"name":"perfluorohexansulfonová kyselina (PFHxS)","range":""},{"name":"perfluoroheptansulfonová kyselina (PFHpS)","range":""},{"name":"perfluoroktansulfonová kyselina (PFOS)","range":""},{"name":"perfluorononansulfonová kyselina (PFNS)","range":""},{"name":"perfluorodekansulfonová kyselina (PFDS)","range":""},{"name":"perfluoroundekansulfonová kyselina (PFUnDS)","range":""},{"name":"perfluorododekansulfonová kyselina (PFDoDS)","range":""},{"name":"perfluorotridekansulfonová kyselina (PFTrDS)","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["Suma PFAS (z obliczeń)"],"computed_en":["sum of PFAS"],"computed_zh":["PFAS总量（计算）"],"computed_cs":["suma PFAS"],"activity":"Oznaczanie związków per- i polifluoroalkilowych (PFAS) metodą LC/MS/MS oraz ich sumy obliczeniowo z wartości zmierzonych\nZakres:\nKwas perfluorobutanowy (PFBA)\nKwas perfluoropentanowy (PFPeA)\nKwas perfluoroheksanowy (PFHxA)\nKwas perfluoroheptanowy (PFHpA)\nKwas perfluorooktanowy (PFOA)\nKwas perfluorononanowy (PFNA)\nKwas perfluorodekanowy (PFDA)\nKwas perfluoroundekanowy (PFUnDA)\nKwas perfluorododekanowy (PFDoDA)\nKwas perfluorotridekanowy (PFTrDA)\nKwas perfluorobutanosulfonowy (PFBS)\nKwas perfluoropentanosulfonowy (PFPeS)\nKwas perfluoroheksanosulfonowy (PFHxS)\nKwas perfluoroheptanosulfonowy (PFHpS)\nKwas perfluorooktanosulfonowy (PFOS)\nKwas perfluorononanosulfonowy (PFNS)\nKwas perfluorodekanosulfonowy (PFDS)\nKwas perfluoroundekanosulfonowy (PFUnDS)\nKwas perfluorododekanosulfonowy (PFDoDS)\nKwas perfluorotridekanosulfonowy (PFTrDS)","reference":"SOP 105 (EPA Method 533; EPA Method 537.1)","norm_bases":["SOP 105","EPA Method 533","EPA Method 537.1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Woda przeznaczona do spożycia, podziemna, surowa, powierzchniowa oraz woda z kąpielisk i basenów","note_en":"Drinking, ground, raw, surface water and water from bathing places and swimming pools","note_zh":"饮用水、地下水、原水、地表水及游泳场所和泳池用水","note_cs":"Voda pitná, podzemní, surová, povrchová a voda z koupališť a bazénů","search_text":"Wody Oznaczanie związków per- i polifluoroalkilowych (PFAS) metodą LC/MS/MS oraz ich sumy obliczeniowo z wartości zmierzonych Kwas perfluorobutanowy (PFBA)  Kwas perfluoropentanowy (PFPeA)  Kwas perfluoroheksanowy (PFHxA)  Kwas perfluoroheptanowy (PFHpA)  Kwas perfluorooktanowy (PFOA)  Kwas perfluorononanowy (PFNA)  Kwas perfluorodekanowy (PFDA)  Kwas perfluoroundekanowy (PFUnDA)  Kwas perfluorododekanowy (PFDoDA)  Kwas perfluorotridekanowy (PFTrDA)  Kwas perfluorobutanosulfonowy (PFBS)  Kwas perfluoropentanosulfonowy (PFPeS)  Kwas perfluoroheksanosulfonowy (PFHxS)  Kwas perfluoroheptanosulfonowy (PFHpS)  Kwas perfluorooktanosulfonowy (PFOS)  Kwas perfluorononanosulfonowy (PFNS)  Kwas perfluorodekanosulfonowy (PFDS)  Kwas perfluoroundekanosulfonowy (PFUnDS)  Kwas perfluorododekanosulfonowy (PFDoDS)  Kwas perfluorotridekanosulfonowy (PFTrDS)  Suma PFAS (z obliczeń) Vody Stanovení per- a polyfluorovaných alkylových sloučenin (PFAS) metodou LC/MS/MS a jejich sumy dopočtem z naměřených hodnot perfluorobutanová kyselina (PFBA)  perfluoropentanová kyselina (PFPeA)  perfluorohexanová kyselina (PFHxA)  perfluoroheptanová kyselina (PFHpA)  perfluoroktanová kyselina (PFOA)  perfluorononanová kyselina (PFNA)  perfluorodekanová kyselina (PFDA)  perfluoroundekanová kyselina (PFUnDA)  perflurododekanová kyselina (PFDoDA)  perflurotridekanová kyselina (PFTrDA)  perfluorobutansulfonová kyselina (PFBS)  perfluoropentansulfonová kyselina (PFPeS)  perfluorohexansulfonová kyselina (PFHxS)  perfluoroheptansulfonová kyselina (PFHpS)  perfluoroktansulfonová kyselina (PFOS)  perfluorononansulfonová kyselina (PFNS)  perfluorodekansulfonová kyselina (PFDS)  perfluoroundekansulfonová kyselina (PFUnDS)  perfluorododekansulfonová kyselina (PFDoDS)  perfluorotridekansulfonová kyselina (PFTrDS)  suma PFAS SOP 105 (EPA Method 533; EPA Method 537.1) Wody Oznaczanie zwiazkow per- i polifluoroalkilowych (PFAS) metoda LC/MS/MS oraz ich sumy obliczeniowo z wartosci zmierzonych Kwas perfluorobutanowy (PFBA)  Kwas perfluoropentanowy (PFPeA)  Kwas perfluoroheksanowy (PFHxA)  Kwas perfluoroheptanowy (PFHpA)  Kwas perfluorooktanowy (PFOA)  Kwas perfluorononanowy (PFNA)  Kwas perfluorodekanowy (PFDA)  Kwas perfluoroundekanowy (PFUnDA)  Kwas perfluorododekanowy (PFDoDA)  Kwas perfluorotridekanowy (PFTrDA)  Kwas perfluorobutanosulfonowy (PFBS)  Kwas perfluoropentanosulfonowy (PFPeS)  Kwas perfluoroheksanosulfonowy (PFHxS)  Kwas perfluoroheptanosulfonowy (PFHpS)  Kwas perfluorooktanosulfonowy (PFOS)  Kwas perfluorononanosulfonowy (PFNS)  Kwas perfluorodekanosulfonowy (PFDS)  Kwas perfluoroundekanosulfonowy (PFUnDS)  Kwas perfluorododekanosulfonowy (PFDoDS)  Kwas perfluorotridekanosulfonowy (PFTrDS)  Suma PFAS (z obliczen) Vody Stanoveni per- a polyfluorovanych alkylovych sloucenin (PFAS) metodou LC/MS/MS a jejich sumy dopoctem z namerenych hodnot perfluorobutanova kyselina (PFBA)  perfluoropentanova kyselina (PFPeA)  perfluorohexanova kyselina (PFHxA)  perfluoroheptanova kyselina (PFHpA)  perfluoroktanova kyselina (PFOA)  perfluorononanova kyselina (PFNA)  perfluorodekanova kyselina (PFDA)  perfluoroundekanova kyselina (PFUnDA)  perflurododekanova kyselina (PFDoDA)  perflurotridekanova kyselina (PFTrDA)  perfluorobutansulfonova kyselina (PFBS)  perfluoropentansulfonova kyselina (PFPeS)  perfluorohexansulfonova kyselina (PFHxS)  perfluoroheptansulfonova kyselina (PFHpS)  perfluoroktansulfonova kyselina (PFOS)  perfluorononansulfonova kyselina (PFNS)  perfluorodekansulfonova kyselina (PFDS)  perfluoroundekansulfonova kyselina (PFUnDS)  perfluorododekansulfonova kyselina (PFDoDS)  perfluorotridekansulfonova kyselina (PFTrDS)  suma PFAS SOP 105 (EPA Method 533; EPA Method 537.1)","search_en":"Water Determination of per- and poly-fluorinated alkyl substances (PFAS) by LC/MS/MS method and their sum by calculation from measured values perfluorobutanoic acid (PFBA)  perfluoropentanoic acid (PFPeA)  perfluorohexanoic acid (PFHxA)  perfluoroheptanoic acid (PFHpA)  perfluorooctanoic acid (PFOA)  perfluorononanoic acid (PFNA)  perfluorodecanoic acid (PFDA)  perfluoroundecanoic acid (PFUnDA)  perfluorododecanoic acid (PFDoDA)  perfluorotridecanoic acid (PFTrDA)  perfluorobutanesulfonic acid (PFBS)  perfluoropentanesulfonic acid (PFPeS)  perfluorohexanesulfonic acid (PFHxS)  perfluoroheptanesulfonic acid (PFHpS)  perfluorooctanesulfonic acid (PFOS)  perfluorononanesulfonic acid (PFNS)  perfluorodecanesulfonic acid (PFDS)  perfluoroundecanesulfonic acid (PFUnDS)  perfluorododecanesulfonic acid (PFDoDS)  perfluorotridecanesulfonic acid (PFTrDS)  sum of PFAS SOP 105 (EPA Method 533; EPA Method 537.1)","search_zh":"水 LC/MS/MS法测定全氟和多氟烷基化合物（PFAS），由测量值计算总量 全氟丁酸（PFBA）  全氟戊酸（PFPeA）  全氟己酸（PFHxA）  全氟庚酸（PFHpA）  全氟辛酸（PFOA）  全氟壬酸（PFNA）  全氟癸酸（PFDA）  全氟十一酸（PFUnDA）  全氟十二酸（PFDoDA）  全氟十三酸（PFTrDA）  全氟丁烷磺酸（PFBS）  全氟戊烷磺酸（PFPeS）  全氟己烷磺酸（PFHxS）  全氟庚烷磺酸（PFHpS）  全氟辛烷磺酸（PFOS）  全氟壬烷磺酸（PFNS）  全氟癸烷磺酸（PFDS）  全氟十一烷磺酸（PFUnDS）  全氟十二烷磺酸（PFDoDS）  全氟十三烷磺酸（PFTrDS）  PFAS总量（计算） SOP 105 (EPA Method 533; EPA Method 537.1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"89f91087c669c200c2b91c35","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"1","test_object":"Wody surowe, uzdatnione, przeznaczone do spożycia, ciepła woda użytkowa i woda używana do produkcji żywności i napojów, wody butelkowane","test_object_en":"Raw, processed, drinking and domestic hot water and water used in food and beverage production, bottled water","test_object_zh":"原水、成品水、饮用水、生活热水及食品饮料生产用水、瓶装水","test_object_cs":"Surové, vyrobené, pitné teplé užitkové vody a vody užívané při výrobě potravin a nápojů, balené vody","methodology":"Ręczne pobieranie próbek wody przeznaczonej do spożycia","methodology_en":"Manual sampling of drinking water","methodology_zh":"手动饮用水采样","methodology_cs":"Odběr vzorků pitné vody manuálně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ręczne pobieranie próbek wody przeznaczonej do spożycia","reference":"SOP V-1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 19458; ČSN EN ISO 5667-14)","norm_bases":["SOP V-1","ČSN EN ISO 5667-3","ČSN ISO 5667-5","ČSN EN ISO 19458","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody surowe, uzdatnione, przeznaczone do spożycia, ciepła woda użytkowa i woda używana do produkcji żywności i napojów, wody butelkowane Ręczne pobieranie próbek wody przeznaczonej do spożycia Surové, vyrobené, pitné teplé užitkové vody a vody užívané při výrobě potravin a nápojů, balené vody Odběr vzorků pitné vody manuálně SOP V-1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 19458; ČSN EN ISO 5667-14) Wody surowe, uzdatnione, przeznaczone do spozycia, ciepla woda uzytkowa i woda uzywana do produkcji zywnosci i napojow, wody butelkowane Reczne pobieranie probek wody przeznaczonej do spozycia Surove, vyrobene, pitne teple uzitkove vody a vody uzivane pri vyrobe potravin a napoju, balene vody Odber vzorku pitne vody manualne SOP V-1 (CSN EN ISO 5667-3; CSN ISO 5667-5; CSN EN ISO 19458; CSN EN ISO 5667-14)","search_en":"Raw, processed, drinking and domestic hot water and water used in food and beverage production, bottled water Manual sampling of drinking water SOP V-1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 19458; ČSN EN ISO 5667-14)","search_zh":"原水、成品水、饮用水、生活热水及食品饮料生产用水、瓶装水 手动饮用水采样 SOP V-1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 19458; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2d6595ce08db7f02ad977288","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"2","test_object":"Wody podziemne","test_object_en":"Ground water","test_object_zh":"地下水","test_object_cs":"Podzemní vody","methodology":"Pobieranie próbek wód podziemnych ręcznie lub przez pompowanie","methodology_en":"Sampling of ground water manually or by pumping","methodology_zh":"手动或泵抽地下水采样","methodology_cs":"Odběr vzorků podzemních vod manuálně nebo čerpáním","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód podziemnych ręcznie lub przez pompowanie","reference":"SOP V-2 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 19458; ČSN EN ISO 5667-14)","norm_bases":["SOP V-2","ČSN EN ISO 5667-3","ČSN ISO 5667-11","ČSN EN ISO 19458","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody podziemne Pobieranie próbek wód podziemnych ręcznie lub przez pompowanie Podzemní vody Odběr vzorků podzemních vod manuálně nebo čerpáním SOP V-2 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 19458; ČSN EN ISO 5667-14) Wody podziemne Pobieranie probek wod podziemnych recznie lub przez pompowanie Podzemni vody Odber vzorku podzemnich vod manualne nebo cerpanim SOP V-2 (CSN EN ISO 5667-3; CSN ISO 5667-11; CSN EN ISO 19458; CSN EN ISO 5667-14)","search_en":"Ground water Sampling of ground water manually or by pumping SOP V-2 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 19458; ČSN EN ISO 5667-14)","search_zh":"地下水 手动或泵抽地下水采样 SOP V-2 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 19458; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bbc2be7e78140fbf2dd3b9b6","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"3","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Pobieranie próbek ścieków ręcznie lub automatycznym próbnikiem","methodology_en":"Sampling of waste water manually or with an automatic sampler","methodology_zh":"手动或自动采样器废水采样","methodology_cs":"Odběr vzorků odpadních vod manuálně nebo automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków ręcznie lub automatycznym próbnikiem","reference":"SOP V-3 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","norm_bases":["SOP V-3","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków ręcznie lub automatycznym próbnikiem Odpadní vody Odběr vzorků odpadních vod manuálně nebo automatickým vzorkovačem SOP V-3 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14) Scieki Pobieranie probek sciekow recznie lub automatycznym probnikiem Odpadni vody Odber vzorku odpadnich vod manualne nebo automatickym vzorkovacem SOP V-3 (CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14)","search_en":"Waste water Sampling of waste water manually or with an automatic sampler SOP V-3 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","search_zh":"废水 手动或自动采样器废水采样 SOP V-3 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43fa03e9b0d9bc46146f5d56","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"4","test_object":"Wody powierzchniowe ze zbiorników wodnych, rzek i potoków","test_object_en":"Surface water from reservoirs, rivers and streams","test_object_zh":"水库、河流和溪流地表水","test_object_cs":"Povrchové vody z vodních nádrží, řek a potoků","methodology":"Pobieranie próbek wód powierzchniowych ręcznie, przez pompowanie lub automatycznym próbnikiem","methodology_en":"Sampling of surface water manually, by pumping or with an automatic sampler","methodology_zh":"手动、泵抽或自动采样器地表水采样","methodology_cs":"Odběr vzorků povrchových vod manuálně, čerpáním nebo automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód powierzchniowych ręcznie, przez pompowanie lub automatycznym próbnikiem","reference":"SOP V-4 (ČSN EN ISO 5667-3; ČSN EN ISO 5667-4; ČSN ISO 5667-6; ČSN EN ISO 19458; ČSN EN ISO 5667-14)","norm_bases":["SOP V-4","ČSN EN ISO 5667-3","ČSN EN ISO 5667-4","ČSN ISO 5667-6","ČSN EN ISO 19458","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe ze zbiorników wodnych, rzek i potoków Pobieranie próbek wód powierzchniowych ręcznie, przez pompowanie lub automatycznym próbnikiem Povrchové vody z vodních nádrží, řek a potoků Odběr vzorků povrchových vod manuálně, čerpáním nebo automatickým vzorkovačem SOP V-4 (ČSN EN ISO 5667-3; ČSN EN ISO 5667-4; ČSN ISO 5667-6; ČSN EN ISO 19458; ČSN EN ISO 5667-14) Wody powierzchniowe ze zbiornikow wodnych, rzek i potokow Pobieranie probek wod powierzchniowych recznie, przez pompowanie lub automatycznym probnikiem Povrchove vody z vodnich nadrzi, rek a potoku Odber vzorku povrchovych vod manualne, cerpanim nebo automatickym vzorkovacem SOP V-4 (CSN EN ISO 5667-3; CSN EN ISO 5667-4; CSN ISO 5667-6; CSN EN ISO 19458; CSN EN ISO 5667-14)","search_en":"Surface water from reservoirs, rivers and streams Sampling of surface water manually, by pumping or with an automatic sampler SOP V-4 (ČSN EN ISO 5667-3; ČSN EN ISO 5667-4; ČSN ISO 5667-6; ČSN EN ISO 19458; ČSN EN ISO 5667-14)","search_zh":"水库、河流和溪流地表水 手动、泵抽或自动采样器地表水采样 SOP V-4 (ČSN EN ISO 5667-3; ČSN EN ISO 5667-4; ČSN ISO 5667-6; ČSN EN ISO 19458; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7ef2aa5957d3a3fc4aa2e0d1","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"5","test_object":"Woda z kąpielisk, basenów i saun","test_object_en":"Water from bathing places, swimming pools and saunas","test_object_zh":"游泳场所、泳池和桑拿用水","test_object_cs":"Vody z koupališť, bazénů a saun","methodology":"Ręczne pobieranie próbek wody z kąpielisk","methodology_en":"Manual sampling of water from bathing places","methodology_zh":"手动游泳场所用水采样","methodology_cs":"Odběr vzorků vod z koupališť manuálně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ręczne pobieranie próbek wody z kąpielisk","reference":"SOP V-5 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 5667-14)","norm_bases":["SOP V-5","Vyhláška č. 238/2011 Sb.","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda z kąpielisk, basenów i saun Ręczne pobieranie próbek wody z kąpielisk Vody z koupališť, bazénů a saun Odběr vzorků vod z koupališť manuálně SOP V-5 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 5667-14) Woda z kapielisk, basenow i saun Reczne pobieranie probek wody z kapielisk Vody z koupalist, bazenu a saun Odber vzorku vod z koupalist manualne SOP V-5 (Vyhlaska c. 238/2011 Sb.; CSN EN ISO 5667-14)","search_en":"Water from bathing places, swimming pools and saunas Manual sampling of water from bathing places SOP V-5 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 5667-14)","search_zh":"游泳场所、泳池和桑拿用水 手动游泳场所用水采样 SOP V-5 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"62c831099cc232ddda99ea8d","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"6","test_object":"Odpady, komposty","test_object_en":"Waste, composts","test_object_zh":"废物、堆肥","test_object_cs":"Odpady, komposty","methodology":"Pobieranie próbek odpadów i kompostów","methodology_en":"Sampling of waste and composts","methodology_zh":"废物和堆肥采样","methodology_cs":"Vzorkování odpadů a kompostů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek odpadów i kompostów","reference":"SOP V-6 (Metodický pokyn MŽP ČR ke vzorkování odpadů - Věstník MŽP ČR č. 6/2008; Vyhláška č. 273/2021 Sb.; ČSN EN 14899; ČSN 46 5735)","norm_bases":["SOP V-6","Metodický pokyn MŽP ČR ke vzorkování odpadů - Věstník MŽP ČR č. 6/2008","Vyhláška č. 273/2021 Sb.","ČSN EN 14899","ČSN 46 5735"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Odpady, komposty Pobieranie próbek odpadów i kompostów Odpady, komposty Vzorkování odpadů a kompostů SOP V-6 (Metodický pokyn MŽP ČR ke vzorkování odpadů - Věstník MŽP ČR č. 6/2008; Vyhláška č. 273/2021 Sb.; ČSN EN 14899; ČSN 46 5735) Odpady, komposty Pobieranie probek odpadow i kompostow Odpady, komposty Vzorkovani odpadu a kompostu SOP V-6 (Metodicky pokyn MZP CR ke vzorkovani odpadu - Vestnik MZP CR c. 6/2008; Vyhlaska c. 273/2021 Sb.; CSN EN 14899; CSN 46 5735)","search_en":"Waste, composts Sampling of waste and composts SOP V-6 (Metodický pokyn MŽP ČR ke vzorkování odpadů - Věstník MŽP ČR č. 6/2008; Vyhláška č. 273/2021 Sb.; ČSN EN 14899; ČSN 46 5735)","search_zh":"废物、堆肥 废物和堆肥采样 SOP V-6 (Metodický pokyn MŽP ČR ke vzorkování odpadů - Věstník MŽP ČR č. 6/2008; Vyhláška č. 273/2021 Sb.; ČSN EN 14899; ČSN 46 5735)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e31149d5c700f6ccd831fba5","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"7","test_object":"Gleby","test_object_en":"Soils","test_object_zh":"土壤","test_object_cs":"Půdy","methodology":"Pobieranie próbek gleb rolniczych","methodology_en":"Sampling of agricultural soils","methodology_zh":"农业土壤采样","methodology_cs":"Vzorkování zemědělských půd","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek gleb rolniczych","reference":"SOP V-7 (Metodika monitorování zemědělských a lesních půd, UKZÚZ 1995; Vyhláška č. 275/1998 Sb.)","norm_bases":["SOP V-7","Metodika monitorování zemědělských a lesních půd, UKZÚZ 1995","Vyhláška č. 275/1998 Sb."],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby Pobieranie próbek gleb rolniczych Půdy Vzorkování zemědělských půd SOP V-7 (Metodika monitorování zemědělských a lesních půd, UKZÚZ 1995; Vyhláška č. 275/1998 Sb.) Gleby Pobieranie probek gleb rolniczych Pudy Vzorkovani zemedelskych pud SOP V-7 (Metodika monitorovani zemedelskych a lesnich pud, UKZUZ 1995; Vyhlaska c. 275/1998 Sb.)","search_en":"Soils Sampling of agricultural soils SOP V-7 (Metodika monitorování zemědělských a lesních půd, UKZÚZ 1995; Vyhláška č. 275/1998 Sb.)","search_zh":"土壤 农业土壤采样 SOP V-7 (Metodika monitorování zemědělských a lesních půd, UKZÚZ 1995; Vyhláška č. 275/1998 Sb.)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aaa2f17978eaea6e7abcb1e7","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"8","test_object":"Osady (szlamy)","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kaly","methodology":"Pobieranie próbek osadów ściekowych","methodology_en":"Sampling of sewage sludge","methodology_zh":"污水处理厂污泥采样","methodology_cs":"Vzorkování čistírenských kalů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek osadów ściekowych","reference":"SOP V-8 (ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; Vyhláška č. 437/2016 Sb.)","norm_bases":["SOP V-8","ČSN EN ISO 5667-13","ČSN EN ISO 5667-14","ČSN EN ISO 5667-15","Vyhláška č. 437/2016 Sb."],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady (szlamy) Pobieranie próbek osadów ściekowych Kaly Vzorkování čistírenských kalů SOP V-8 (ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; Vyhláška č. 437/2016 Sb.) Osady (szlamy) Pobieranie probek osadow sciekowych Kaly Vzorkovani cistirenskych kalu SOP V-8 (CSN EN ISO 5667-13; CSN EN ISO 5667-14; CSN EN ISO 5667-15; Vyhlaska c. 437/2016 Sb.)","search_en":"Sludge Sampling of sewage sludge SOP V-8 (ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; Vyhláška č. 437/2016 Sb.)","search_zh":"污泥 污水处理厂污泥采样 SOP V-8 (ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; Vyhláška č. 437/2016 Sb.)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2f8b37895cb5ea7e5e39c63c","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"9","test_object":"Pasze","test_object_en":"Feedstuffs","test_object_zh":"饲料","test_object_cs":"Krmiva","methodology":"Pobieranie próbek pasz","methodology_en":"Sampling of feedstuffs","methodology_zh":"饲料采样","methodology_cs":"Vzorkování krmiv","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek pasz","reference":"SOP V-9 (Nařízení komise (ES) č. 152/2009, příloha č. I; Vyhláška č. 415/2009 Sb.)","norm_bases":["SOP V-9","Nařízení komise (ES) č. 152/2009, příloha č. I","Vyhláška č. 415/2009 Sb."],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze Pobieranie próbek pasz Krmiva Vzorkování krmiv SOP V-9 (Nařízení komise (ES) č. 152/2009, příloha č. I; Vyhláška č. 415/2009 Sb.) Pasze Pobieranie probek pasz Krmiva Vzorkovani krmiv SOP V-9 (Narizeni komise (ES) c. 152/2009, priloha c. I; Vyhlaska c. 415/2009 Sb.)","search_en":"Feedstuffs Sampling of feedstuffs SOP V-9 (Nařízení komise (ES) č. 152/2009, příloha č. I; Vyhláška č. 415/2009 Sb.)","search_zh":"饲料 饲料采样 SOP V-9 (Nařízení komise (ES) č. 152/2009, příloha č. I; Vyhláška č. 415/2009 Sb.)","categories":["food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"02d1411619de46c5f2f9083b","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"10","test_object":"Owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy","test_object_en":"Fruit and vegetables, cereal grain, oilseeds, spices","test_object_zh":"水果和蔬菜、谷物籽粒、油料种子、香料","test_object_cs":"Plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření","methodology":"Pobieranie próbek produktów rolnych","methodology_en":"Sampling of agricultural products","methodology_zh":"农产品采样","methodology_cs":"Vzorkování zemědělských produktů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek produktów rolnych","reference":"SOP V-11 (Nařízení vlády č.79/2007 Sb.; Nařízení komise (ES) č. 152/2009; Vyhláška č. 415/2009 Sb.; ČSN ISO 6639-2)","norm_bases":["SOP V-11","Nařízení vlády č.79/2007 Sb.","Nařízení komise (ES) č. 152/2009","Vyhláška č. 415/2009 Sb.","ČSN ISO 6639-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Owoce i warzywa, ziarno zbóż, nasiona oleiste, przyprawy Pobieranie próbek produktów rolnych Plody ovoce a zeleniny, zrno obilnin, semena olejnin, koření Vzorkování zemědělských produktů SOP V-11 (Nařízení vlády č.79/2007 Sb.; Nařízení komise (ES) č. 152/2009; Vyhláška č. 415/2009 Sb.; ČSN ISO 6639-2) Owoce i warzywa, ziarno zboz, nasiona oleiste, przyprawy Pobieranie probek produktow rolnych Plody ovoce a zeleniny, zrno obilnin, semena olejnin, koreni Vzorkovani zemedelskych produktu SOP V-11 (Narizeni vlady c.79/2007 Sb.; Narizeni komise (ES) c. 152/2009; Vyhlaska c. 415/2009 Sb.; CSN ISO 6639-2)","search_en":"Fruit and vegetables, cereal grain, oilseeds, spices Sampling of agricultural products SOP V-11 (Nařízení vlády č.79/2007 Sb.; Nařízení komise (ES) č. 152/2009; Vyhláška č. 415/2009 Sb.; ČSN ISO 6639-2)","search_zh":"水果和蔬菜、谷物籽粒、油料种子、香料 农产品采样 SOP V-11 (Nařízení vlády č.79/2007 Sb.; Nařízení komise (ES) č. 152/2009; Vyhláška č. 415/2009 Sb.; ČSN ISO 6639-2)","categories":["food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":82,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"af079a66be7a26d676684c3d","lab_id":"69ad52a4de79e566650fd322","country":"CZ","accr_number":"1255","accr_body":"ČIA","row_label":"11","test_object":"Osady denne","test_object_en":"Bottom sediments","test_object_zh":"底泥","test_object_cs":"Dnové sedimenty","methodology":"Pobieranie próbek osadów dennych ręcznie lub próbnikiem","methodology_en":"Sampling of sediments manually or with a sampler","methodology_zh":"手动或采样器沉积物采样","methodology_cs":"Vzorkování sedimentů manuálně nebo vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek osadów dennych ręcznie lub próbnikiem","reference":"SOP V-12 (ČSN ISO 5667-12)","norm_bases":["SOP V-12","ČSN ISO 5667-12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady denne Pobieranie próbek osadów dennych ręcznie lub próbnikiem Dnové sedimenty Vzorkování sedimentů manuálně nebo vzorkovačem SOP V-12 (ČSN ISO 5667-12) Osady denne Pobieranie probek osadow dennych recznie lub probnikiem Dnove sedimenty Vzorkovani sedimentu manualne nebo vzorkovacem SOP V-12 (CSN ISO 5667-12)","search_en":"Bottom sediments Sampling of sediments manually or with a sampler SOP V-12 (ČSN ISO 5667-12)","search_zh":"底泥 手动或采样器沉积物采样 SOP V-12 (ČSN ISO 5667-12)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":83,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}