{"lab":{"_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","address":"Počerady č.p. 57, 440 01 Louny","categories":["water","environment","petro"],"city":"Louny","imported_at":"2026-03-08T10:42:44.590Z","methods_count":36,"name":"Elektrárna Počerady, a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1241_270_2025_CS.pdf","1241_270_2025_EN.pdf"],"scope_summary":"Analizy chemiczne wód odpadowych, powierzchniowych i technologicznych, gipsu, stabilizatu i produktów naftowych, w zakresie określonym w załączniku do świadectwa.","search_text":"elektrárna počerady, a.s. počerady č.p. 57, 440 01 louny 1241","status":"active","updated_at":"2026-03-08T14:52:09.232Z","valid_from":"","valid_until":"18-10-2027","website":"www.7.cz","map_coord":[50.357291,13.79692],"map_geo":"nominatim-city","certificate_date":"17.07.2026","certificate_no":"347/2026","certificate_replaces":"270/2025 z 04.06.2025","en_official":false,"fields_of_testing":[{"codes":"","pl":"Analizy chemiczne wód odpadowych, powierzchniowych i technologicznych, gipsu, stabilizatu i produktów naftowych, w zakresie określonym w załączniku do świadectwa.","en":"Chemical analyses of waste, surface and process water, gypsum, stabilizate and petroleum products, as specified in the appendix to this certificate.","zh":"废水、地表水和工艺用水、石膏、稳定化产物及石油产品的化学分析，范围见本证书附件。","cs":"Chemické analýzy odpadních, povrchových a technologických vod, sádrovce, stabilizátu a ropných produktů, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze","lab_division_cs":"Zkušební laboratoř","lab_division_en":"Testing Laboratory","lab_division_zh":"检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"AAS","pl":"Atomowy spektrofotometr absorpcyjny","en":"Atomic absorption spectrophotometer","zh":"原子吸收分光光度计","cs":"Atomový absorpční spektrofotometr"},{"abbr":"SPP","pl":"Standardowa procedura robocza","en":"Standard working procedure","zh":"标准工作程序","cs":"Standardní pracovní postup"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"6eab23f9211684ce754c53601791d3f967714352b82cbfa57d91c1028dc6602b","source_pdf_url":"https://www.cai.cz/OA/pdf/347_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"3d633af35f4f20e6c0c1435a","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"1","test_object":"Wody odpadowe, powierzchniowe, wody technologiczne","test_object_en":"Waste and surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní, povrchové vody, technologické vody","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法pH测定","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"SPP 3 (ČSN ISO 10523)","norm_bases":["SPP 3","ČSN ISO 10523"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie pH metodą potencjometryczną Odpadní, povrchové vody, technologické vody Stanovení pH potenciometricky SPP 3 (ČSN ISO 10523) Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie pH metoda potencjometryczna Odpadni, povrchove vody, technologicke vody Stanoveni pH potenciometricky SPP 3 (CSN ISO 10523)","search_en":"Waste and surface water, process water Determination of pH by potentiometry SPP 3 (ČSN ISO 10523)","search_zh":"废水、地表水、工艺用水 电位法pH测定 SPP 3 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"35046fc0358bbecfd9738067","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"2","test_object":"Wody odpadowe, powierzchniowe, wody technologiczne","test_object_en":"Waste and surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní, povrchové vody, technologické vody","methodology":"Oznaczanie przewodności elektrycznej właściwej","methodology_en":"Determination of electrical conductivity","methodology_zh":"电导率测定","methodology_cs":"Stanovení elektrické konduktivity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej właściwej","reference":"SPP 4 (ČSN EN 27888)","norm_bases":["SPP 4","ČSN EN 27888"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie przewodności elektrycznej właściwej Odpadní, povrchové vody, technologické vody Stanovení elektrické konduktivity SPP 4 (ČSN EN 27888) Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie przewodnosci elektrycznej wlasciwej Odpadni, povrchove vody, technologicke vody Stanoveni elektricke konduktivity SPP 4 (CSN EN 27888)","search_en":"Waste and surface water, process water Determination of electrical conductivity SPP 4 (ČSN EN 27888)","search_zh":"废水、地表水、工艺用水 电导率测定 SPP 4 (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f44f4bd48a55d3ccd4ff84d3","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"3","test_object":"Wody odpadowe, powierzchniowe, wody technologiczne","test_object_en":"Waste and surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní, povrchové vody, technologické vody","methodology":"Oznaczanie zawiesin (NL105) metodą wagową","methodology_en":"Determination of suspended solids (NL105) by gravimetry","methodology_zh":"重量法悬浮物（NL105）测定","methodology_cs":"Stanovení nerozpuštěných látek (NL105) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesin (NL105) metodą wagową","reference":"SPP 6 (ČSN EN 872)","norm_bases":["SPP 6","ČSN EN 872"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie zawiesin (NL105) metodą wagową Odpadní, povrchové vody, technologické vody Stanovení nerozpuštěných látek (NL105) gravimetricky SPP 6 (ČSN EN 872) Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie zawiesin (NL105) metoda wagowa Odpadni, povrchove vody, technologicke vody Stanoveni nerozpustenych latek (NL105) gravimetricky SPP 6 (CSN EN 872)","search_en":"Waste and surface water, process water Determination of suspended solids (NL105) by gravimetry SPP 6 (ČSN EN 872)","search_zh":"废水、地表水、工艺用水 重量法悬浮物（NL105）测定 SPP 6 (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4c97744f00a15593ba4a5785","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"4","test_object":"Wody odpadowe, powierzchniowe, wody technologiczne","test_object_en":"Waste and surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní, povrchové vody, technologické vody","methodology":"Oznaczanie substancji rozpuszczonych (RL105, RL550) metodą wagową","methodology_en":"Determination of dissolved solids (RL105, RL550) by gravimetry","methodology_zh":"重量法溶解性固体（RL105、RL550）测定","methodology_cs":"Stanovení rozpuštěných látek (RL105, RL550) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych (RL105, RL550) metodą wagową","reference":"SPP 7 (ČSN 75 7346)","norm_bases":["SPP 7","ČSN 75 7346"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie substancji rozpuszczonych (RL105, RL550) metodą wagową Odpadní, povrchové vody, technologické vody Stanovení rozpuštěných látek (RL105, RL550) gravimetricky SPP 7 (ČSN 75 7346) Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie substancji rozpuszczonych (RL105, RL550) metoda wagowa Odpadni, povrchove vody, technologicke vody Stanoveni rozpustenych latek (RL105, RL550) gravimetricky SPP 7 (CSN 75 7346)","search_en":"Waste and surface water, process water Determination of dissolved solids (RL105, RL550) by gravimetry SPP 7 (ČSN 75 7346)","search_zh":"废水、地表水、工艺用水 重量法溶解性固体（RL105、RL550）测定 SPP 7 (ČSN 75 7346)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4c48dc3a63adce7e57126ade","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"5","test_object":"Wody odpadowe, powierzchniowe, wody technologiczne","test_object_en":"Waste and surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní, povrchové vody, technologické vody","methodology":"Oznaczanie substancji rozpuszczonych jonowo metodą miareczkową (IRL)","methodology_en":"Determination of ionically dissolved substances by titration (IRL)","methodology_zh":"滴定法离子溶解性物质（IRL）测定","methodology_cs":"Stanovení iontově rozpuštěných látek titračně (IRL)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych jonowo metodą miareczkową (IRL)","reference":"SPP 8","norm_bases":["SPP 8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana. Literatura źródłowa: Horáková, Lischke, Grunwald. Chemické a fyzikální analýzy vod, SNTL, ALFA, 1986, wyd. I, rozdz. 2.12 i 2.22.2","note_en":"Process water: power plant operating water, demineralised water. Source literature: Horáková, Lischke, Grunwald. Chemické a fyzikální analýzy vod (Chemical and physical analyses of water), SNTL, ALFA, 1986, 1st edition, chapters 2.12 and 2.22.2","note_zh":"工艺用水：电厂运行用水、除盐水。参考文献：Horáková, Lischke, Grunwald. Chemické a fyzikální analýzy vod（水的化学和物理分析），SNTL, ALFA, 1986年第1版，第2.12章和第2.22.2章","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda. Zdrojová literatura: Horáková, Lischke, Grunwald. Chemické a fyzikální analýzy vod, SNTL, ALFA, 1986, I. vydání, kap. 2.12 a kap. 2.22.2","search_text":"Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie substancji rozpuszczonych jonowo metodą miareczkową (IRL) Odpadní, povrchové vody, technologické vody Stanovení iontově rozpuštěných látek titračně (IRL) SPP 8 Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie substancji rozpuszczonych jonowo metoda miareczkowa (IRL) Odpadni, povrchove vody, technologicke vody Stanoveni iontove rozpustenych latek titracne (IRL) SPP 8","search_en":"Waste and surface water, process water Determination of ionically dissolved substances by titration (IRL) SPP 8","search_zh":"废水、地表水、工艺用水 滴定法离子溶解性物质（IRL）测定 SPP 8","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3df5fe795be12f67c834546d","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"6","test_object":"Wody odpadowe, powierzchniowe, wody technologiczne","test_object_en":"Waste and surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní, povrchové vody, technologické vody","methodology":"Oznaczanie zdolności neutralizacji (ZNK 4,5, KNK4,5, KNK8,3) metodą miareczkową","methodology_en":"Determination of neutralising capacity (ZNK 4.5, KNK4.5, KNK8.3) by titration","methodology_zh":"滴定法测定中和能力（ZNK 4,5、KNK4,5、KNK8,3）","methodology_cs":"Stanovení neutralizační kapacity (ZNK 4,5, KNK4,5, KNK8,3) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zdolności neutralizacji (ZNK 4,5, KNK4,5, KNK8,3) metodą miareczkową","reference":"SPP 5 (ČSN 75 7372; ČSN EN ISO 9963-1)","norm_bases":["SPP 5","ČSN 75 7372","ČSN EN ISO 9963-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie zdolności neutralizacji (ZNK 4,5, KNK4,5, KNK8,3) metodą miareczkową Odpadní, povrchové vody, technologické vody Stanovení neutralizační kapacity (ZNK 4,5, KNK4,5, KNK8,3) titračně SPP 5 (ČSN 75 7372; ČSN EN ISO 9963-1) Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie zdolnosci neutralizacji (ZNK 4,5, KNK4,5, KNK8,3) metoda miareczkowa Odpadni, povrchove vody, technologicke vody Stanoveni neutralizacni kapacity (ZNK 4,5, KNK4,5, KNK8,3) titracne SPP 5 (CSN 75 7372; CSN EN ISO 9963-1)","search_en":"Waste and surface water, process water Determination of neutralising capacity (ZNK 4.5, KNK4.5, KNK8.3) by titration SPP 5 (ČSN 75 7372; ČSN EN ISO 9963-1)","search_zh":"废水、地表水、工艺用水 滴定法测定中和能力（ZNK 4,5、KNK4,5、KNK8,3） SPP 5 (ČSN 75 7372; ČSN EN ISO 9963-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cd6e79695e34e1232fb50564","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"7","test_object":"Wody odpadowe, powierzchniowe, wody technologiczne","test_object_en":"Waste and surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní, povrchové vody, technologické vody","methodology":"Oznaczanie sumy wapnia (Ca) i magnezu (Mg) metodą miareczkową","methodology_en":"Determination of the sum of calcium (Ca) and magnesium (Mg) by titration","methodology_zh":"滴定法测定钙（Ca）镁（Mg）总量","methodology_cs":"Stanovení sumy vápníku (Ca) a hořčíku (Mg) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie sumy wapnia (Ca) i magnezu (Mg) metodą miareczkową","reference":"SPP 13 (ČSN ISO 6059)","norm_bases":["SPP 13","ČSN ISO 6059"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie sumy wapnia (Ca) i magnezu (Mg) metodą miareczkową Odpadní, povrchové vody, technologické vody Stanovení sumy vápníku (Ca) a hořčíku (Mg) titračně SPP 13 (ČSN ISO 6059) Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie sumy wapnia (Ca) i magnezu (Mg) metoda miareczkowa Odpadni, povrchove vody, technologicke vody Stanoveni sumy vapniku (Ca) a horciku (Mg) titracne SPP 13 (CSN ISO 6059)","search_en":"Waste and surface water, process water Determination of the sum of calcium (Ca) and magnesium (Mg) by titration SPP 13 (ČSN ISO 6059)","search_zh":"废水、地表水、工艺用水 滴定法测定钙（Ca）镁（Mg）总量 SPP 13 (ČSN ISO 6059)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0d5190e19458438d71baa62d","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"8","test_object":"Wody powierzchniowe, wody technologiczne","test_object_en":"Surface water, process water","test_object_zh":"地表水、工艺用水","test_object_cs":"Povrchové vody, technologické vody","methodology":"Oznaczanie wapnia (Ca) metodą miareczkową i magnezu (Mg) obliczeniowo","methodology_en":"Determination of calcium (Ca) by titration and magnesium (Mg) by calculation","methodology_zh":"滴定法测定钙（Ca）并计算镁（Mg）","methodology_cs":"Stanovení vápníku (Ca) titračně a hořčíku (Mg) dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wapnia (Ca) metodą miareczkową i magnezu (Mg) obliczeniowo","reference":"SPP 14 (ČSN ISO 6058)","norm_bases":["SPP 14","ČSN ISO 6058"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Wody powierzchniowe, wody technologiczne Oznaczanie wapnia (Ca) metodą miareczkową i magnezu (Mg) obliczeniowo Povrchové vody, technologické vody Stanovení vápníku (Ca) titračně a hořčíku (Mg) dopočtem SPP 14 (ČSN ISO 6058) Wody powierzchniowe, wody technologiczne Oznaczanie wapnia (Ca) metoda miareczkowa i magnezu (Mg) obliczeniowo Povrchove vody, technologicke vody Stanoveni vapniku (Ca) titracne a horciku (Mg) dopoctem SPP 14 (CSN ISO 6058)","search_en":"Surface water, process water Determination of calcium (Ca) by titration and magnesium (Mg) by calculation SPP 14 (ČSN ISO 6058)","search_zh":"地表水、工艺用水 滴定法测定钙（Ca）并计算镁（Mg） SPP 14 (ČSN ISO 6058)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5df79c2bdabe6901854b8ce0","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"9","test_object":"Wody powierzchniowe, wody technologiczne","test_object_en":"Surface water, process water","test_object_zh":"地表水、工艺用水","test_object_cs":"Povrchové vody, technologické vody","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu metodą nadmanganianową (ChZT-Mn) metodą miareczkową","methodology_en":"Determination of chemical oxygen demand by permanganate (CODMn) by titration","methodology_zh":"滴定法测定高锰酸盐化学需氧量（CHSKMn）","methodology_cs":"Stanovení chemické spotřeby kyslíku manganistanem (CHSKMn) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu metodą nadmanganianową (ChZT-Mn) metodą miareczkową","reference":"SPP 9 (ČSN EN ISO 8467)","norm_bases":["SPP 9","ČSN EN ISO 8467"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Wody powierzchniowe, wody technologiczne Oznaczanie chemicznego zapotrzebowania tlenu metodą nadmanganianową (ChZT-Mn) metodą miareczkową Povrchové vody, technologické vody Stanovení chemické spotřeby kyslíku manganistanem (CHSKMn) titračně SPP 9 (ČSN EN ISO 8467) Wody powierzchniowe, wody technologiczne Oznaczanie chemicznego zapotrzebowania tlenu metoda nadmanganianowa (ChZT-Mn) metoda miareczkowa Povrchove vody, technologicke vody Stanoveni chemicke spotreby kysliku manganistanem (CHSKMn) titracne SPP 9 (CSN EN ISO 8467)","search_en":"Surface water, process water Determination of chemical oxygen demand by permanganate (CODMn) by titration SPP 9 (ČSN EN ISO 8467)","search_zh":"地表水、工艺用水 滴定法测定高锰酸盐化学需氧量（CHSKMn） SPP 9 (ČSN EN ISO 8467)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f5703c0d77aea84278ee3891","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"10","test_object":"Wody odpadowe, powierzchniowe","test_object_en":"Waste and surface water","test_object_zh":"废水、地表水","test_object_cs":"Odpadní, povrchové vody","methodology":"Oznaczanie siarczanów (SO42-) metodą miareczkową","methodology_en":"Determination of sulphates (SO42-) by titration","methodology_zh":"滴定法测定硫酸盐（SO42-）","methodology_cs":"Stanovení síranů (SO42-) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie siarczanów (SO42-) metodą miareczkową","reference":"SPP 15 (ČSN 75 7477)","norm_bases":["SPP 15","ČSN 75 7477"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody odpadowe, powierzchniowe Oznaczanie siarczanów (SO42-) metodą miareczkową Odpadní, povrchové vody Stanovení síranů (SO42-) titračně SPP 15 (ČSN 75 7477) Wody odpadowe, powierzchniowe Oznaczanie siarczanow (SO42-) metoda miareczkowa Odpadni, povrchove vody Stanoveni siranu (SO42-) titracne SPP 15 (CSN 75 7477)","search_en":"Waste and surface water Determination of sulphates (SO42-) by titration SPP 15 (ČSN 75 7477)","search_zh":"废水、地表水 滴定法测定硫酸盐（SO42-） SPP 15 (ČSN 75 7477)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7b1cfe847e555dbecb68ae2d","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"11","test_object":"Wody odpadowe, powierzchniowe","test_object_en":"Waste and surface water","test_object_zh":"废水、地表水","test_object_cs":"Odpadní, povrchové vody","methodology":"Oznaczanie chlorków (Cl-) metodą miareczkową (argentometryczną)","methodology_en":"Determination of chlorides (Cl-) by titration (argentometric)","methodology_zh":"滴定法（银量法）测定氯化物（Cl-）","methodology_cs":"Stanovení chloridů (Cl-) titračně (argentometricky)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków (Cl-) metodą miareczkową (argentometryczną)","reference":"SPP 16 (ČSN ISO 9297)","norm_bases":["SPP 16","ČSN ISO 9297"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody odpadowe, powierzchniowe Oznaczanie chlorków (Cl-) metodą miareczkową (argentometryczną) Odpadní, povrchové vody Stanovení chloridů (Cl-) titračně (argentometricky) SPP 16 (ČSN ISO 9297) Wody odpadowe, powierzchniowe Oznaczanie chlorkow (Cl-) metoda miareczkowa (argentometryczna) Odpadni, povrchove vody Stanoveni chloridu (Cl-) titracne (argentometricky) SPP 16 (CSN ISO 9297)","search_en":"Waste and surface water Determination of chlorides (Cl-) by titration (argentometric) SPP 16 (ČSN ISO 9297)","search_zh":"废水、地表水 滴定法（银量法）测定氯化物（Cl-） SPP 16 (ČSN ISO 9297)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cb54a1dd943ca79c2725a876","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"12","test_object":"Wody odpadowe, powierzchniowe, wody technologiczne","test_object_en":"Waste and surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní, povrchové vody, technologické vody","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu (ChZT-Cr) metodą spektrofotometryczną zestawem Merck","methodology_en":"Determination of chemical oxygen demand (CODCr) by spectrophotometry using a Merck kit","methodology_zh":"使用Merck试剂盒分光光度法测定化学需氧量（CHSKCr）","methodology_cs":"Stanovení chemické spotřeby kyslíku (CHSKCr) spektrofotometricky setem Merck","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu (ChZT-Cr) metodą spektrofotometryczną zestawem Merck","reference":"SPP 10 (ČSN ISO 15705, manuál firmy Merck)","norm_bases":["SPP 10","ČSN ISO 15705","manuál firmy Merck"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie chemicznego zapotrzebowania tlenu (ChZT-Cr) metodą spektrofotometryczną zestawem Merck Odpadní, povrchové vody, technologické vody Stanovení chemické spotřeby kyslíku (CHSKCr) spektrofotometricky setem Merck SPP 10 (ČSN ISO 15705, manuál firmy Merck) Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie chemicznego zapotrzebowania tlenu (ChZT-Cr) metoda spektrofotometryczna zestawem Merck Odpadni, povrchove vody, technologicke vody Stanoveni chemicke spotreby kysliku (CHSKCr) spektrofotometricky setem Merck SPP 10 (CSN ISO 15705, manual firmy Merck)","search_en":"Waste and surface water, process water Determination of chemical oxygen demand (CODCr) by spectrophotometry using a Merck kit SPP 10 (ČSN ISO 15705, manuál firmy Merck)","search_zh":"废水、地表水、工艺用水 使用Merck试剂盒分光光度法测定化学需氧量（CHSKCr） SPP 10 (ČSN ISO 15705, manuál firmy Merck)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1fbebfae05bb8c182b4543a6","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"13","test_object":"Wody odpadowe, powierzchniowe, wody technologiczne","test_object_en":"Waste and surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní, povrchové vody, technologické vody","methodology":"Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną zestawem Merck","methodology_en":"Determination of ammonium ions (NH4+) by spectrophotometry using a Merck kit","methodology_zh":"使用Merck试剂盒分光光度法测定铵离子（NH4+）","methodology_cs":"Stanovení amonných iontů (NH4+) spektrofotometricky setem Merck","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną zestawem Merck","reference":"SPP 22 (ČSN ISO 7150-1, manuál firmy Merck)","norm_bases":["SPP 22","ČSN ISO 7150-1","manuál firmy Merck"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną zestawem Merck Odpadní, povrchové vody, technologické vody Stanovení amonných iontů (NH4+) spektrofotometricky setem Merck SPP 22 (ČSN ISO 7150-1, manuál firmy Merck) Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie jonow amonowych (NH4+) metoda spektrofotometryczna zestawem Merck Odpadni, povrchove vody, technologicke vody Stanoveni amonnych iontu (NH4+) spektrofotometricky setem Merck SPP 22 (CSN ISO 7150-1, manual firmy Merck)","search_en":"Waste and surface water, process water Determination of ammonium ions (NH4+) by spectrophotometry using a Merck kit SPP 22 (ČSN ISO 7150-1, manuál firmy Merck)","search_zh":"废水、地表水、工艺用水 使用Merck试剂盒分光光度法测定铵离子（NH4+） SPP 22 (ČSN ISO 7150-1, manuál firmy Merck)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0b6e8928dd4e9b668dc0f3d7","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"14","test_object":"Wody odpadowe, powierzchniowe, wody technologiczne","test_object_en":"Waste and surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní, povrchové vody, technologické vody","methodology":"Oznaczanie fosforu ogólnego (Pcelk) metodą spektrofotometryczną zestawem Merck","methodology_en":"Determination of total phosphorus (Ptot) by spectrophotometry using a Merck kit","methodology_zh":"使用Merck试剂盒分光光度法测定总磷（Pcelk）","methodology_cs":"Stanovení celkového fosforu (Pcelk) spektrofotometricky setem Merck","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforu ogólnego (Pcelk) metodą spektrofotometryczną zestawem Merck","reference":"SPP 24 (ČSN EN ISO 6878, manuál firmy Merck)","norm_bases":["SPP 24","ČSN EN ISO 6878","manuál firmy Merck"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie fosforu ogólnego (Pcelk) metodą spektrofotometryczną zestawem Merck Odpadní, povrchové vody, technologické vody Stanovení celkového fosforu (Pcelk) spektrofotometricky setem Merck SPP 24 (ČSN EN ISO 6878, manuál firmy Merck) Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie fosforu ogolnego (Pcelk) metoda spektrofotometryczna zestawem Merck Odpadni, povrchove vody, technologicke vody Stanoveni celkoveho fosforu (Pcelk) spektrofotometricky setem Merck SPP 24 (CSN EN ISO 6878, manual firmy Merck)","search_en":"Waste and surface water, process water Determination of total phosphorus (Ptot) by spectrophotometry using a Merck kit SPP 24 (ČSN EN ISO 6878, manuál firmy Merck)","search_zh":"废水、地表水、工艺用水 使用Merck试剂盒分光光度法测定总磷（Pcelk） SPP 24 (ČSN EN ISO 6878, manuál firmy Merck)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8621e67af95a2e2b8fff3a48","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"15","test_object":"Ścieki, wody technologiczne","test_object_en":"Waste water, process water","test_object_zh":"废水、工艺用水","test_object_cs":"Odpadní vody, technologické vody","methodology":"Oznaczanie azotu ogólnego (Ncelk) metodą spektrofotometryczną zestawem Merck","methodology_en":"Determination of total nitrogen (Ntot) by spectrophotometry using a Merck kit","methodology_zh":"使用Merck试剂盒分光光度法测定总氮（Ncelk）","methodology_cs":"Stanovení celkového dusíku (Ncelk) spektrofotometricky setem Merck","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu ogólnego (Ncelk) metodą spektrofotometryczną zestawem Merck","reference":"SPP 36 (ČSN EN ISO 11905-1, manuál firmy Merck)","norm_bases":["SPP 36","ČSN EN ISO 11905-1","manuál firmy Merck"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Ścieki, wody technologiczne Oznaczanie azotu ogólnego (Ncelk) metodą spektrofotometryczną zestawem Merck Odpadní vody, technologické vody Stanovení celkového dusíku (Ncelk) spektrofotometricky setem Merck SPP 36 (ČSN EN ISO 11905-1, manuál firmy Merck) Scieki, wody technologiczne Oznaczanie azotu ogolnego (Ncelk) metoda spektrofotometryczna zestawem Merck Odpadni vody, technologicke vody Stanoveni celkoveho dusiku (Ncelk) spektrofotometricky setem Merck SPP 36 (CSN EN ISO 11905-1, manual firmy Merck)","search_en":"Waste water, process water Determination of total nitrogen (Ntot) by spectrophotometry using a Merck kit SPP 36 (ČSN EN ISO 11905-1, manuál firmy Merck)","search_zh":"废水、工艺用水 使用Merck试剂盒分光光度法测定总氮（Ncelk） SPP 36 (ČSN EN ISO 11905-1, manuál firmy Merck)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c9b0f513feb57647631e5497","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"16","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Oznaczanie ogólnego węgla organicznego (OWO) metodą spektrofotometryczną zestawem Merck","methodology_en":"Determination of total organic carbon (TOC) by spectrophotometry using a Merck kit","methodology_zh":"使用Merck试剂盒分光光度法测定总有机碳（TOC）","methodology_cs":"Stanovení celkového organického uhlíku (TOC) spektrofotometricky setem Merck","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ogólnego węgla organicznego (OWO) metodą spektrofotometryczną zestawem Merck","reference":"SPP 106 (ČSN EN 1484, manuál firmy Merck)","norm_bases":["SPP 106","ČSN EN 1484","manuál firmy Merck"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Oznaczanie ogólnego węgla organicznego (OWO) metodą spektrofotometryczną zestawem Merck Odpadní vody Stanovení celkového organického uhlíku (TOC) spektrofotometricky setem Merck SPP 106 (ČSN EN 1484, manuál firmy Merck) Scieki Oznaczanie ogolnego wegla organicznego (OWO) metoda spektrofotometryczna zestawem Merck Odpadni vody Stanoveni celkoveho organickeho uhliku (TOC) spektrofotometricky setem Merck SPP 106 (CSN EN 1484, manual firmy Merck)","search_en":"Waste water Determination of total organic carbon (TOC) by spectrophotometry using a Merck kit SPP 106 (ČSN EN 1484, manuál firmy Merck)","search_zh":"废水 使用Merck试剂盒分光光度法测定总有机碳（TOC） SPP 106 (ČSN EN 1484, manuál firmy Merck)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4e9f39bb56dd51957893e7d3","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"17","test_object":"Wody odpadowe, powierzchniowe","test_object_en":"Waste and surface water","test_object_zh":"废水、地表水","test_object_cs":"Odpadní, povrchové vody","methodology":"Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) sondą membranową","methodology_en":"Determination of biochemical oxygen demand (BOD5) by membrane probe","methodology_zh":"膜电极法测定生化需氧量（BSK5）","methodology_cs":"Stanovení biochemické spotřeby kyslíku (BSK5) membránovou sondou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) sondą membranową","reference":"SPP 12 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN EN ISO 5814)","norm_bases":["SPP 12","ČSN EN ISO 5815-1","ČSN EN 1899-2","ČSN EN ISO 5814"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody odpadowe, powierzchniowe Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) sondą membranową Odpadní, povrchové vody Stanovení biochemické spotřeby kyslíku (BSK5) membránovou sondou SPP 12 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN EN ISO 5814) Wody odpadowe, powierzchniowe Oznaczanie biochemicznego zapotrzebowania tlenu (BZT5) sonda membranowa Odpadni, povrchove vody Stanoveni biochemicke spotreby kysliku (BSK5) membranovou sondou SPP 12 (CSN EN ISO 5815-1; CSN EN 1899-2; CSN EN ISO 5814)","search_en":"Waste and surface water Determination of biochemical oxygen demand (BOD5) by membrane probe SPP 12 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN EN ISO 5814)","search_zh":"废水、地表水 膜电极法测定生化需氧量（BSK5） SPP 12 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN EN ISO 5814)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fa0079524efca06e29413a47","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"18","test_object":"Wody odpadowe, powierzchniowe, wody technologiczne","test_object_en":"Waste and surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní, povrchové vody, technologické vody","methodology":"Oznaczanie rozpuszczonych soli nieorganicznych (RAS) metodą wagową","methodology_en":"Determination of dissolved inorganic salts (RAS) by gravimetry","methodology_zh":"重量法测定溶解性无机盐（RAS）","methodology_cs":"Stanovení rozpuštěných anorganických solí (RAS) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rozpuszczonych soli nieorganicznych (RAS) metodą wagową","reference":"SPP 132 (ČSN 75 7347)","norm_bases":["SPP 132","ČSN 75 7347"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie rozpuszczonych soli nieorganicznych (RAS) metodą wagową Odpadní, povrchové vody, technologické vody Stanovení rozpuštěných anorganických solí (RAS) gravimetricky SPP 132 (ČSN 75 7347) Wody odpadowe, powierzchniowe, wody technologiczne Oznaczanie rozpuszczonych soli nieorganicznych (RAS) metoda wagowa Odpadni, povrchove vody, technologicke vody Stanoveni rozpustenych anorganickych soli (RAS) gravimetricky SPP 132 (CSN 75 7347)","search_en":"Waste and surface water, process water Determination of dissolved inorganic salts (RAS) by gravimetry SPP 132 (ČSN 75 7347)","search_zh":"废水、地表水、工艺用水 重量法测定溶解性无机盐（RAS） SPP 132 (ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8c076c5769882bc6abc70320","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"19","test_object":"Wody zasilające i kotłowe","test_object_en":"Feed and boiler water","test_object_zh":"给水和锅炉水","test_object_cs":"Napájecí a kotelní vody","methodology":"Oznaczanie żelaza (Fe) metodą AAS z kuwetą grafitową","methodology_en":"Determination of iron (Fe) by AAS with graphite furnace","methodology_zh":"石墨炉原子吸收光谱法测定铁（Fe）","methodology_cs":"Stanovení železa (Fe) a metodou AAS grafitovou kyvetou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie żelaza (Fe) metodą AAS z kuwetą grafitową","reference":"SPP 37 (ČSN EN ISO 15586)","norm_bases":["SPP 37","ČSN EN ISO 15586"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody zasilające i kotłowe Oznaczanie żelaza (Fe) metodą AAS z kuwetą grafitową Napájecí a kotelní vody Stanovení železa (Fe) a metodou AAS grafitovou kyvetou SPP 37 (ČSN EN ISO 15586) Wody zasilajace i kotlowe Oznaczanie zelaza (Fe) metoda AAS z kuweta grafitowa Napajeci a kotelni vody Stanoveni zeleza (Fe) a metodou AAS grafitovou kyvetou SPP 37 (CSN EN ISO 15586)","search_en":"Feed and boiler water Determination of iron (Fe) by AAS with graphite furnace SPP 37 (ČSN EN ISO 15586)","search_zh":"给水和锅炉水 石墨炉原子吸收光谱法测定铁（Fe） SPP 37 (ČSN EN ISO 15586)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"74a20f48991f2511d45013e3","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"20","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Oznaczanie kadmu (Cd) metodą AAS z kuwetą grafitową","methodology_en":"Determination of cadmium (Cd) by AAS with graphite furnace","methodology_zh":"石墨炉原子吸收光谱法测定镉（Cd）","methodology_cs":"Stanovení kadmia (Cd) metodou AAS grafitovou kyvetou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kadmu (Cd) metodą AAS z kuwetą grafitową","reference":"SPP 39 (ČSN EN ISO 5961)","norm_bases":["SPP 39","ČSN EN ISO 5961"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Oznaczanie kadmu (Cd) metodą AAS z kuwetą grafitową Odpadní vody Stanovení kadmia (Cd) metodou AAS grafitovou kyvetou SPP 39 (ČSN EN ISO 5961) Scieki Oznaczanie kadmu (Cd) metoda AAS z kuweta grafitowa Odpadni vody Stanoveni kadmia (Cd) metodou AAS grafitovou kyvetou SPP 39 (CSN EN ISO 5961)","search_en":"Waste water Determination of cadmium (Cd) by AAS with graphite furnace SPP 39 (ČSN EN ISO 5961)","search_zh":"废水 石墨炉原子吸收光谱法测定镉（Cd） SPP 39 (ČSN EN ISO 5961)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2d4d8d99a1b775919a0d11f4","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"21","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Oznaczanie niklu (Ni) metodą AAS z kuwetą grafitową","methodology_en":"Determination of nickel (Ni) by AAS with graphite furnace","methodology_zh":"石墨炉原子吸收光谱法测定镍（Ni）","methodology_cs":"Stanovení niklu (Ni) metodou AAS grafitovou kyvetou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie niklu (Ni) metodą AAS z kuwetą grafitową","reference":"SPP 97 (ČSN EN ISO 15586)","norm_bases":["SPP 97","ČSN EN ISO 15586"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Oznaczanie niklu (Ni) metodą AAS z kuwetą grafitową Odpadní vody Stanovení niklu (Ni) metodou AAS grafitovou kyvetou SPP 97 (ČSN EN ISO 15586) Scieki Oznaczanie niklu (Ni) metoda AAS z kuweta grafitowa Odpadni vody Stanoveni niklu (Ni) metodou AAS grafitovou kyvetou SPP 97 (CSN EN ISO 15586)","search_en":"Waste water Determination of nickel (Ni) by AAS with graphite furnace SPP 97 (ČSN EN ISO 15586)","search_zh":"废水 石墨炉原子吸收光谱法测定镍（Ni） SPP 97 (ČSN EN ISO 15586)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"842a3473cf1cbf9517fb8d54","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"22","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Oznaczanie cynku (Zn) metodą AAS z kuwetą grafitową","methodology_en":"Determination of zinc (Zn) by AAS with graphite furnace","methodology_zh":"石墨炉原子吸收光谱法测定锌（Zn）","methodology_cs":"Stanovení zinku (Zn) metodou AAS grafitovou kyvetou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cynku (Zn) metodą AAS z kuwetą grafitową","reference":"SPP 99 (ČSN EN ISO 15586)","norm_bases":["SPP 99","ČSN EN ISO 15586"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Oznaczanie cynku (Zn) metodą AAS z kuwetą grafitową Odpadní vody Stanovení zinku (Zn) metodou AAS grafitovou kyvetou SPP 99 (ČSN EN ISO 15586) Scieki Oznaczanie cynku (Zn) metoda AAS z kuweta grafitowa Odpadni vody Stanoveni zinku (Zn) metodou AAS grafitovou kyvetou SPP 99 (CSN EN ISO 15586)","search_en":"Waste water Determination of zinc (Zn) by AAS with graphite furnace SPP 99 (ČSN EN ISO 15586)","search_zh":"废水 石墨炉原子吸收光谱法测定锌（Zn） SPP 99 (ČSN EN ISO 15586)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0261629d8a561f5950121601","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"23","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Oznaczanie arsenu (As) metodą AAS z kuwetą grafitową","methodology_en":"Determination of arsenic (As) by AAS with graphite furnace","methodology_zh":"石墨炉原子吸收光谱法测定砷（As）","methodology_cs":"Stanovení arsenu (As) metodou AAS grafitovou kyvetou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie arsenu (As) metodą AAS z kuwetą grafitową","reference":"SPP 40 (ČSN EN ISO 15586)","norm_bases":["SPP 40","ČSN EN ISO 15586"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Oznaczanie arsenu (As) metodą AAS z kuwetą grafitową Odpadní vody Stanovení arsenu (As) metodou AAS grafitovou kyvetou SPP 40 (ČSN EN ISO 15586) Scieki Oznaczanie arsenu (As) metoda AAS z kuweta grafitowa Odpadni vody Stanoveni arsenu (As) metodou AAS grafitovou kyvetou SPP 40 (CSN EN ISO 15586)","search_en":"Waste water Determination of arsenic (As) by AAS with graphite furnace SPP 40 (ČSN EN ISO 15586)","search_zh":"废水 石墨炉原子吸收光谱法测定砷（As） SPP 40 (ČSN EN ISO 15586)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d4ea4a550374f03b66e31202","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"24","test_object":"Gips, wyciągi z gipsu","test_object_en":"Gypsum, gypsum leachates","test_object_zh":"石膏、石膏浸出液","test_object_cs":"Sádrovec, výluhy ze sádrovce","methodology":"Oznaczanie chlorków (Cl-) metodą miareczkową (potencjometryczną)","methodology_en":"Determination of chlorides (Cl-) by titration (potentiometric)","methodology_zh":"滴定法（电位法）测定氯化物（Cl-）","methodology_cs":"Stanovení chloridů (Cl-) titračně (potenciometricky)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków (Cl-) metodą miareczkową (potencjometryczną)","reference":"SPP 109 (Manuál firmy Mettler Toledo)","norm_bases":["SPP 109","Manuál firmy Mettler Toledo"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gips, wyciągi z gipsu Oznaczanie chlorków (Cl-) metodą miareczkową (potencjometryczną) Sádrovec, výluhy ze sádrovce Stanovení chloridů (Cl-) titračně (potenciometricky) SPP 109 (Manuál firmy Mettler Toledo) Gips, wyciagi z gipsu Oznaczanie chlorkow (Cl-) metoda miareczkowa (potencjometryczna) Sadrovec, vyluhy ze sadrovce Stanoveni chloridu (Cl-) titracne (potenciometricky) SPP 109 (Manual firmy Mettler Toledo)","search_en":"Gypsum, gypsum leachates Determination of chlorides (Cl-) by titration (potentiometric) SPP 109 (Manuál firmy Mettler Toledo)","search_zh":"石膏、石膏浸出液 滴定法（电位法）测定氯化物（Cl-） SPP 109 (Manuál firmy Mettler Toledo)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7b4368b2fdb758188908a305","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"25","test_object":"Gips, stabilizat, wyciągi z gipsu i stabilizatu","test_object_en":"Gypsum, stabilizate, leachates of gypsum and stabilizate","test_object_zh":"石膏、稳定化产物及其浸出液","test_object_cs":"Sádrovec, stabilizát, výluhy ze sádrovce, stabilizátu","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法pH测定","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"SPP 48 (ČSN 72 1070)","norm_bases":["SPP 48","ČSN 72 1070"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Stabilizat: certyfikowany wyrób na bazie popiołu","note_en":"Stabilizate: certified ash-based product","note_zh":"稳定化产物：经认证的灰基产品","note_cs":"Stabilizát: certifikovaný výrobek na bázi popela","search_text":"Gips, stabilizat, wyciągi z gipsu i stabilizatu Oznaczanie pH metodą potencjometryczną Sádrovec, stabilizát, výluhy ze sádrovce, stabilizátu Stanovení pH potenciometricky SPP 48 (ČSN 72 1070) Gips, stabilizat, wyciagi z gipsu i stabilizatu Oznaczanie pH metoda potencjometryczna Sadrovec, stabilizat, vyluhy ze sadrovce, stabilizatu Stanoveni pH potenciometricky SPP 48 (CSN 72 1070)","search_en":"Gypsum, stabilizate, leachates of gypsum and stabilizate Determination of pH by potentiometry SPP 48 (ČSN 72 1070)","search_zh":"石膏、稳定化产物及其浸出液 电位法pH测定 SPP 48 (ČSN 72 1070)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a63dc459d3ad445c16432201","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"26","test_object":"Oleje i produkty naftowe","test_object_en":"Oils and petroleum products","test_object_zh":"油品和石油产品","test_object_cs":"Oleje a ropné produkty","methodology":"Oznaczanie wody metodą kulometryczną Karla Fischera","methodology_en":"Determination of water by coulometric Karl Fischer titration","methodology_zh":"卡尔·费休库仑法测定水分","methodology_cs":"Stanovení vody coulometricky metodou Karl Fischer","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wody metodą kulometryczną Karla Fischera","reference":"SPP 77 (ČSN EN ISO 12937)","norm_bases":["SPP 77","ČSN EN ISO 12937"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Produkty naftowe: olej napędowy, ciecze hydrauliczne, oleje silnikowe, sprężarkowe, przekładniowe, turbinowe i przepracowane","note_en":"Petroleum products: diesel fuel, hydraulic fluids, engine, compressor, gear, turbine and used oils","note_zh":"石油产品：柴油、液压液、发动机油、压缩机油、齿轮油、汽轮机油和废油","note_cs":"Ropné produkty: nafta, hydraulické kapaliny, oleje motorové, kompresorové, převodové, turbínové a upotřebené","search_text":"Oleje i produkty naftowe Oznaczanie wody metodą kulometryczną Karla Fischera Oleje a ropné produkty Stanovení vody coulometricky metodou Karl Fischer SPP 77 (ČSN EN ISO 12937) Oleje i produkty naftowe Oznaczanie wody metoda kulometryczna Karla Fischera Oleje a ropne produkty Stanoveni vody coulometricky metodou Karl Fischer SPP 77 (CSN EN ISO 12937)","search_en":"Oils and petroleum products Determination of water by coulometric Karl Fischer titration SPP 77 (ČSN EN ISO 12937)","search_zh":"油品和石油产品 卡尔·费休库仑法测定水分 SPP 77 (ČSN EN ISO 12937)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7fdd1f1ffa51fd8569418156","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"27","test_object":"Oleje i produkty naftowe","test_object_en":"Oils and petroleum products","test_object_zh":"油品和石油产品","test_object_cs":"Oleje a ropné produkty","methodology":"Oznaczanie kodu czystości licznikiem cząstek","methodology_en":"Determination of cleanliness code by particle counter","methodology_zh":"颗粒计数器测定清洁度等级代码","methodology_cs":"Stanovení kódu čistoty čítačem částic","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kodu czystości licznikiem cząstek","reference":"SPP 79 (ČSN ISO 4406)","norm_bases":["SPP 79","ČSN ISO 4406"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Produkty naftowe: olej napędowy, ciecze hydrauliczne, oleje silnikowe, sprężarkowe, przekładniowe, turbinowe i przepracowane","note_en":"Petroleum products: diesel fuel, hydraulic fluids, engine, compressor, gear, turbine and used oils","note_zh":"石油产品：柴油、液压液、发动机油、压缩机油、齿轮油、汽轮机油和废油","note_cs":"Ropné produkty: nafta, hydraulické kapaliny, oleje motorové, kompresorové, převodové, turbínové a upotřebené","search_text":"Oleje i produkty naftowe Oznaczanie kodu czystości licznikiem cząstek Oleje a ropné produkty Stanovení kódu čistoty čítačem částic SPP 79 (ČSN ISO 4406) Oleje i produkty naftowe Oznaczanie kodu czystosci licznikiem czastek Oleje a ropne produkty Stanoveni kodu cistoty citacem castic SPP 79 (CSN ISO 4406)","search_en":"Oils and petroleum products Determination of cleanliness code by particle counter SPP 79 (ČSN ISO 4406)","search_zh":"油品和石油产品 颗粒计数器测定清洁度等级代码 SPP 79 (ČSN ISO 4406)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b9bda994bed8a27afd9752ec","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"28","test_object":"Oleje i produkty naftowe","test_object_en":"Oils and petroleum products","test_object_zh":"油品和石油产品","test_object_cs":"Oleje a ropné produkty","methodology":"Oznaczanie liczby kwasowej metodą kulometryczną","methodology_en":"Determination of acid number by coulometry","methodology_zh":"库仑法测定酸值","methodology_cs":"Stanovení čísla kyselosti coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby kwasowej metodą kulometryczną","reference":"SPP 75 (ČSN ISO 6618, Manuál firmy DIRAM)","norm_bases":["SPP 75","ČSN ISO 6618","Manuál firmy DIRAM"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Produkty naftowe: olej napędowy, ciecze hydrauliczne, oleje silnikowe, sprężarkowe, przekładniowe, turbinowe i przepracowane","note_en":"Petroleum products: diesel fuel, hydraulic fluids, engine, compressor, gear, turbine and used oils","note_zh":"石油产品：柴油、液压液、发动机油、压缩机油、齿轮油、汽轮机油和废油","note_cs":"Ropné produkty: nafta, hydraulické kapaliny, oleje motorové, kompresorové, převodové, turbínové a upotřebené","search_text":"Oleje i produkty naftowe Oznaczanie liczby kwasowej metodą kulometryczną Oleje a ropné produkty Stanovení čísla kyselosti coulometricky SPP 75 (ČSN ISO 6618, Manuál firmy DIRAM) Oleje i produkty naftowe Oznaczanie liczby kwasowej metoda kulometryczna Oleje a ropne produkty Stanoveni cisla kyselosti coulometricky SPP 75 (CSN ISO 6618, Manual firmy DIRAM)","search_en":"Oils and petroleum products Determination of acid number by coulometry SPP 75 (ČSN ISO 6618, Manuál firmy DIRAM)","search_zh":"油品和石油产品 库仑法测定酸值 SPP 75 (ČSN ISO 6618, Manuál firmy DIRAM)","categories":["petro"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8214da0bc3e8bb97b268f2f8","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"29","test_object":"Popiół lotny","test_object_en":"Fly ash","test_object_zh":"粉煤灰","test_object_cs":"Popílek","methodology":"Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną zestawem Merck","methodology_en":"Determination of ammonium ions (NH4+) by spectrophotometry using a Merck kit","methodology_zh":"使用Merck试剂盒分光光度法测定铵离子（NH4+）","methodology_cs":"Stanovení amonných iontů (NH4+) spektrofotometricky setem Merck","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną zestawem Merck","reference":"SPP 122 (ČSN ISO 7150-1, manuál firmy Merck)","norm_bases":["SPP 122","ČSN ISO 7150-1","manuál firmy Merck"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Popiół lotny Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną zestawem Merck Popílek Stanovení amonných iontů (NH4+) spektrofotometricky setem Merck SPP 122 (ČSN ISO 7150-1, manuál firmy Merck) Popiol lotny Oznaczanie jonow amonowych (NH4+) metoda spektrofotometryczna zestawem Merck Popilek Stanoveni amonnych iontu (NH4+) spektrofotometricky setem Merck SPP 122 (CSN ISO 7150-1, manual firmy Merck)","search_en":"Fly ash Determination of ammonium ions (NH4+) by spectrophotometry using a Merck kit SPP 122 (ČSN ISO 7150-1, manuál firmy Merck)","search_zh":"粉煤灰 使用Merck试剂盒分光光度法测定铵离子（NH4+） SPP 122 (ČSN ISO 7150-1, manuál firmy Merck)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7885e2879853686535077a10","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"30","test_object":"Zawiesina gipsowa","test_object_en":"Gypsum slurry","test_object_zh":"石膏浆液","test_object_cs":"Sádrovcová suspenze","methodology":"Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną zestawem Merck","methodology_en":"Determination of ammonium ions (NH4+) by spectrophotometry using a Merck kit","methodology_zh":"使用Merck试剂盒分光光度法测定铵离子（NH4+）","methodology_cs":"Stanovení amonných iontů (NH4+) spektrofotometricky setem Merck","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną zestawem Merck","reference":"SPP 123 (ČSN ISO 7150-1, manuál firmy Merck)","norm_bases":["SPP 123","ČSN ISO 7150-1","manuál firmy Merck"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zawiesina gipsowa Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną zestawem Merck Sádrovcová suspenze Stanovení amonných iontů (NH4+) spektrofotometricky setem Merck SPP 123 (ČSN ISO 7150-1, manuál firmy Merck) Zawiesina gipsowa Oznaczanie jonow amonowych (NH4+) metoda spektrofotometryczna zestawem Merck Sadrovcova suspenze Stanoveni amonnych iontu (NH4+) spektrofotometricky setem Merck SPP 123 (CSN ISO 7150-1, manual firmy Merck)","search_en":"Gypsum slurry Determination of ammonium ions (NH4+) by spectrophotometry using a Merck kit SPP 123 (ČSN ISO 7150-1, manuál firmy Merck)","search_zh":"石膏浆液 使用Merck试剂盒分光光度法测定铵离子（NH4+） SPP 123 (ČSN ISO 7150-1, manuál firmy Merck)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4471e5fe20346eb66edbc478","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"31","test_object":"Ścieki, wody powierzchniowe, wody technologiczne","test_object_en":"Waste water, surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní vody, povrchové vody, technologické vody","methodology":"Oznaczanie chlorków (Cl-) analizatorem Gallery z detekcją fotometryczną","methodology_en":"Determination of chlorides (Cl-) by Gallery analyser with photometric detection","methodology_zh":"Gallery分析仪光度检测法测定氯化物（Cl-）","methodology_cs":"Stanovení chloridů (Cl-) analyzátorem Gallery s fotometrickou detekcí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków (Cl-) analizatorem Gallery z detekcją fotometryczną","reference":"SPP 135 (postup Thermo Scientific; ČSN EN ISO 15923-1)","norm_bases":["SPP 135","postup Thermo Scientific","ČSN EN ISO 15923-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Ścieki, wody powierzchniowe, wody technologiczne Oznaczanie chlorków (Cl-) analizatorem Gallery z detekcją fotometryczną Odpadní vody, povrchové vody, technologické vody Stanovení chloridů (Cl-) analyzátorem Gallery s fotometrickou detekcí SPP 135 (postup Thermo Scientific; ČSN EN ISO 15923-1) Scieki, wody powierzchniowe, wody technologiczne Oznaczanie chlorkow (Cl-) analizatorem Gallery z detekcja fotometryczna Odpadni vody, povrchove vody, technologicke vody Stanoveni chloridu (Cl-) analyzatorem Gallery s fotometrickou detekci SPP 135 (postup Thermo Scientific; CSN EN ISO 15923-1)","search_en":"Waste water, surface water, process water Determination of chlorides (Cl-) by Gallery analyser with photometric detection SPP 135 (postup Thermo Scientific; ČSN EN ISO 15923-1)","search_zh":"废水、地表水、工艺用水 Gallery分析仪光度检测法测定氯化物（Cl-） SPP 135 (postup Thermo Scientific; ČSN EN ISO 15923-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9459a537981c595976482051","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"32","test_object":"Ścieki, wody powierzchniowe, wody technologiczne","test_object_en":"Waste water, surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní vody, povrchové vody, technologické vody","methodology":"Oznaczanie siarczanów (SO42-) analizatorem Gallery z detekcją fotometryczną","methodology_en":"Determination of sulphates (SO42-) by Gallery analyser with photometric detection","methodology_zh":"Gallery分析仪光度检测法测定硫酸盐（SO42-）","methodology_cs":"Stanovení síranů (SO42-) analyzátorem Gallery s fotometrickou detekcí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie siarczanów (SO42-) analizatorem Gallery z detekcją fotometryczną","reference":"SPP 136 (postup Thermo Scientific; ČSN EN ISO 15923-1)","norm_bases":["SPP 136","postup Thermo Scientific","ČSN EN ISO 15923-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Ścieki, wody powierzchniowe, wody technologiczne Oznaczanie siarczanów (SO42-) analizatorem Gallery z detekcją fotometryczną Odpadní vody, povrchové vody, technologické vody Stanovení síranů (SO42-) analyzátorem Gallery s fotometrickou detekcí SPP 136 (postup Thermo Scientific; ČSN EN ISO 15923-1) Scieki, wody powierzchniowe, wody technologiczne Oznaczanie siarczanow (SO42-) analizatorem Gallery z detekcja fotometryczna Odpadni vody, povrchove vody, technologicke vody Stanoveni siranu (SO42-) analyzatorem Gallery s fotometrickou detekci SPP 136 (postup Thermo Scientific; CSN EN ISO 15923-1)","search_en":"Waste water, surface water, process water Determination of sulphates (SO42-) by Gallery analyser with photometric detection SPP 136 (postup Thermo Scientific; ČSN EN ISO 15923-1)","search_zh":"废水、地表水、工艺用水 Gallery分析仪光度检测法测定硫酸盐（SO42-） SPP 136 (postup Thermo Scientific; ČSN EN ISO 15923-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c28a9052511cb311d3a60954","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"33","test_object":"Ścieki, wody powierzchniowe, wody technologiczne","test_object_en":"Waste water, surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní vody, povrchové vody, technologické vody","methodology":"Oznaczanie azotanów (NO3-) analizatorem Gallery z detekcją fotometryczną i azotu nieorganicznego (Nanorg) obliczeniowo","methodology_en":"Determination of nitrates (NO3-) by Gallery analyser with photometric detection and inorganic nitrogen (Ninorg) by calculation","methodology_zh":"Gallery分析仪光度检测法测定硝酸盐（NO3-）并计算无机氮（Nanorg）","methodology_cs":"Stanovení dusičnanů (NO3-) analyzátorem Gallery s fotometrickou detekcí a anorganického dusíku (Nanorg) dopočtem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotanów (NO3-) analizatorem Gallery z detekcją fotometryczną i azotu nieorganicznego (Nanorg) obliczeniowo","reference":"SPP 137 (postup Thermo Scientific; ČSN EN ISO 15923-1)","norm_bases":["SPP 137","postup Thermo Scientific","ČSN EN ISO 15923-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Ścieki, wody powierzchniowe, wody technologiczne Oznaczanie azotanów (NO3-) analizatorem Gallery z detekcją fotometryczną i azotu nieorganicznego (Nanorg) obliczeniowo Odpadní vody, povrchové vody, technologické vody Stanovení dusičnanů (NO3-) analyzátorem Gallery s fotometrickou detekcí a anorganického dusíku (Nanorg) dopočtem SPP 137 (postup Thermo Scientific; ČSN EN ISO 15923-1) Scieki, wody powierzchniowe, wody technologiczne Oznaczanie azotanow (NO3-) analizatorem Gallery z detekcja fotometryczna i azotu nieorganicznego (Nanorg) obliczeniowo Odpadni vody, povrchove vody, technologicke vody Stanoveni dusicnanu (NO3-) analyzatorem Gallery s fotometrickou detekci a anorganickeho dusiku (Nanorg) dopoctem SPP 137 (postup Thermo Scientific; CSN EN ISO 15923-1)","search_en":"Waste water, surface water, process water Determination of nitrates (NO3-) by Gallery analyser with photometric detection and inorganic nitrogen (Ninorg) by calculation SPP 137 (postup Thermo Scientific; ČSN EN ISO 15923-1)","search_zh":"废水、地表水、工艺用水 Gallery分析仪光度检测法测定硝酸盐（NO3-）并计算无机氮（Nanorg） SPP 137 (postup Thermo Scientific; ČSN EN ISO 15923-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"824b0559cb0ae25dc39b906d","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"34","test_object":"Ścieki, wody powierzchniowe, wody technologiczne","test_object_en":"Waste water, surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní vody, povrchové vody, technologické vody","methodology":"Oznaczanie azotynów (NO2-) analizatorem Gallery z detekcją fotometryczną","methodology_en":"Determination of nitrites (NO2-) by Gallery analyser with photometric detection","methodology_zh":"Gallery分析仪光度检测法测定亚硝酸盐（NO2-）","methodology_cs":"Stanovení dusitanů (NO2-) analyzátorem Gallery s fotometrickou detekcí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotynów (NO2-) analizatorem Gallery z detekcją fotometryczną","reference":"SPP 138 (postup Thermo Scientific; ČSN EN ISO 15923-1)","norm_bases":["SPP 138","postup Thermo Scientific","ČSN EN ISO 15923-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Ścieki, wody powierzchniowe, wody technologiczne Oznaczanie azotynów (NO2-) analizatorem Gallery z detekcją fotometryczną Odpadní vody, povrchové vody, technologické vody Stanovení dusitanů (NO2-) analyzátorem Gallery s fotometrickou detekcí SPP 138 (postup Thermo Scientific; ČSN EN ISO 15923-1) Scieki, wody powierzchniowe, wody technologiczne Oznaczanie azotynow (NO2-) analizatorem Gallery z detekcja fotometryczna Odpadni vody, povrchove vody, technologicke vody Stanoveni dusitanu (NO2-) analyzatorem Gallery s fotometrickou detekci SPP 138 (postup Thermo Scientific; CSN EN ISO 15923-1)","search_en":"Waste water, surface water, process water Determination of nitrites (NO2-) by Gallery analyser with photometric detection SPP 138 (postup Thermo Scientific; ČSN EN ISO 15923-1)","search_zh":"废水、地表水、工艺用水 Gallery分析仪光度检测法测定亚硝酸盐（NO2-） SPP 138 (postup Thermo Scientific; ČSN EN ISO 15923-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"794e8d2b3f9d844aa3702bf3","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"35","test_object":"Ścieki, wody powierzchniowe, wody technologiczne","test_object_en":"Waste water, surface water, process water","test_object_zh":"废水、地表水、工艺用水","test_object_cs":"Odpadní vody, povrchové vody, technologické vody","methodology":"Oznaczanie fluorków (F-) analizatorem Gallery z detekcją fotometryczną","methodology_en":"Determination of fluorides (F-) by Gallery analyser with photometric detection","methodology_zh":"Gallery分析仪光度检测法测定氟化物（F-）","methodology_cs":"Stanovení fluoridů (F-) analyzátorem Gallery s fotometrickou detekcí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fluorków (F-) analizatorem Gallery z detekcją fotometryczną","reference":"SPP 139 (postup Thermo Scientific; ČSN EN ISO 15923-1)","norm_bases":["SPP 139","postup Thermo Scientific","ČSN EN ISO 15923-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wody technologiczne: wody eksploatacyjne elektrowni, woda demineralizowana","note_en":"Process water: power plant operating water, demineralised water","note_zh":"工艺用水：电厂运行用水、除盐水","note_cs":"Technologické vody: provozní vody z elektrárny, demineralizovaná voda","search_text":"Ścieki, wody powierzchniowe, wody technologiczne Oznaczanie fluorków (F-) analizatorem Gallery z detekcją fotometryczną Odpadní vody, povrchové vody, technologické vody Stanovení fluoridů (F-) analyzátorem Gallery s fotometrickou detekcí SPP 139 (postup Thermo Scientific; ČSN EN ISO 15923-1) Scieki, wody powierzchniowe, wody technologiczne Oznaczanie fluorkow (F-) analizatorem Gallery z detekcja fotometryczna Odpadni vody, povrchove vody, technologicke vody Stanoveni fluoridu (F-) analyzatorem Gallery s fotometrickou detekci SPP 139 (postup Thermo Scientific; CSN EN ISO 15923-1)","search_en":"Waste water, surface water, process water Determination of fluorides (F-) by Gallery analyser with photometric detection SPP 139 (postup Thermo Scientific; ČSN EN ISO 15923-1)","search_zh":"废水、地表水、工艺用水 Gallery分析仪光度检测法测定氟化物（F-） SPP 139 (postup Thermo Scientific; ČSN EN ISO 15923-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"377eebc9903a95533846e5a2","lab_id":"69ad52a4de79e566650fd308","country":"CZ","accr_number":"1241","accr_body":"ČIA","row_label":"36","test_object":"Wodny roztwór mocznika, ciecze techniczne","test_object_en":"Aqueous urea solution, technical liquids","test_object_zh":"尿素水溶液、技术液体","test_object_cs":"Vodný roztok močoviny, technické kapaliny","methodology":"Oznaczanie mocznika analizatorem Gallery z detekcją fotometryczną","methodology_en":"Determination of urea by Gallery analyser with photometric detection","methodology_zh":"Gallery分析仪光度检测法测定尿素","methodology_cs":"Stanovení močoviny analyzátorem Gallery s fotometrickou detekcí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mocznika analizatorem Gallery z detekcją fotometryczną","reference":"SPP 141 (postup Thermo Scientific)","norm_bases":["SPP 141","postup Thermo Scientific"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wodny roztwór mocznika, ciecze techniczne Oznaczanie mocznika analizatorem Gallery z detekcją fotometryczną Vodný roztok močoviny, technické kapaliny Stanovení močoviny analyzátorem Gallery s fotometrickou detekcí SPP 141 (postup Thermo Scientific) Wodny roztwor mocznika, ciecze techniczne Oznaczanie mocznika analizatorem Gallery z detekcja fotometryczna Vodny roztok mocoviny, technicke kapaliny Stanoveni mocoviny analyzatorem Gallery s fotometrickou detekci SPP 141 (postup Thermo Scientific)","search_en":"Aqueous urea solution, technical liquids Determination of urea by Gallery analyser with photometric detection SPP 141 (postup Thermo Scientific)","search_zh":"尿素水溶液、技术液体 Gallery分析仪光度检测法测定尿素 SPP 141 (postup Thermo Scientific)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}