{"lab":{"_id":"69ad52a4de79e566650fd2e0","accr_number":"1197","country":"CZ","accr_body":"ČIA","address":"Resslova 956/13, 500 02 Hradec Králové","categories":["construction"],"city":"Hradec Králové","imported_at":"2026-03-08T10:42:44.590Z","methods_count":65,"name":"M.I.S. a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1197_98_2025_CS.pdf","1197_98_2025_EN.pdf"],"scope_summary":"Pobieranie próbek kruszyw, mieszanek asfaltowych i mieszanki betonowej, badania asfaltów, mieszanek asfaltowych, gruntów, kruszyw, betonów, mieszanek do warstw związanych i niezwiązanych nawierzchni oraz badania na konstrukcjach, w zakresie określonym w załączniku do świadectwa.","search_text":"m.i.s. a.s. resslova 956/13, 500 02 hradec králové 1197","status":"active","updated_at":"2026-03-08T14:52:09.057Z","valid_from":"","valid_until":"07-04-2031","website":"www.mishk.cz","location":{"type":"Point","coordinates":[15.8327,50.2093]},"email_confidence":"high","email_mx":true,"email_source":"https://www.mishk.cz","map_coord":[50.216148,15.823985],"map_geo":"nominatim-street","certificate_date":"07.04.2026","certificate_no":"170/2026","certificate_replaces":"98/2025 z 03.03.2025","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pobieranie próbek kruszyw, mieszanek asfaltowych i mieszanki betonowej, badania asfaltów, mieszanek asfaltowych, gruntów, kruszyw, betonów, mieszanek do warstw związanych i niezwiązanych nawierzchni oraz badania na konstrukcjach, w zakresie określonym w załączniku do świadectwa.","en":"Sampling of aggregates, asphalt mixtures and fresh concrete, testing of bitumens, asphalt mixtures, soils, aggregates, concretes, mixtures for bound and unbound pavement layers and testing on structures, as specified in the appendix to this certificate.","zh":"集料、沥青混合料和新拌混凝土采样，沥青、沥青混合料、土、集料、混凝土、路面有结合料及无结合料层混合料检测以及结构现场检测，范围见本证书附件。","cs":"Vzorkování kameniva, asfaltových směsí a čerstvého betonu, zkoušení asfaltů, asfaltových směsí, zemin, kameniva, betonů, směsí pro stmelené a nestmelené vrstvy vozovek a zkoušení na konstrukcích, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Centralne Laboratorium Drogowe","lab_division_cs":"Centrální silniční laboratoř","lab_division_en":"Central Road Laboratory","lab_division_zh":"中央道路实验室","lab_locations":[{"code":null,"name":"M.I.S. a.s.","street":"Resslova 956/13","postal_code":"500 02","city":"Hradec Králové","is_hq":true,"address":"Resslova 956/13, 500 02 Hradec Králové","site":"50002|resslova956/13"},{"code":null,"name":"Hradec Králové","street":"Resslova 956/13","postal_code":"500 02","city":"Hradec Králové","is_hq":false,"address":"Resslova 956/13, 500 02 Hradec Králové","site":"50002|resslova956/13"},{"code":null,"name":"Nový Bydžov","street":"1. Máje 198","postal_code":"504 01","city":"Nový Bydžov","is_hq":false,"address":"1. Máje 198, 504 01 Nový Bydžov","site":"50401|1máje198"},{"code":null,"name":"Chrudim","street":"Za Pivovarem 611","postal_code":"537 01","city":"Chrudim","is_hq":false,"address":"Za Pivovarem 611, 537 01 Chrudim","site":"53701|zapivovarem611"}],"lab_locations_en":[{"code":null,"name":"M.I.S. a.s.","street":"Resslova 956/13","postal_code":"500 02","city":"Hradec Králové","is_hq":true,"address":"Resslova 956/13, 500 02 Hradec Králové","site":"50002|resslova956/13"},{"code":null,"name":"Hradec Králové","street":"Resslova 956/13","postal_code":"500 02","city":"Hradec Králové","is_hq":false,"address":"Resslova 956/13, 500 02 Hradec Králové","site":"50002|resslova956/13"},{"code":null,"name":"Nový Bydžov","street":"1. Máje 198","postal_code":"504 01","city":"Nový Bydžov","is_hq":false,"address":"1. Máje 198, 504 01 Nový Bydžov","site":"50401|1máje198"},{"code":null,"name":"Chrudim","street":"Za Pivovarem 611","postal_code":"537 01","city":"Chrudim","is_hq":false,"address":"Za Pivovarem 611, 537 01 Chrudim","site":"53701|zapivovarem611"}],"lab_locations_zh":[{"code":null,"name":"M.I.S. a.s.","street":"Resslova 956/13","postal_code":"500 02","city":"Hradec Králové","is_hq":true,"address":"Resslova 956/13, 500 02 Hradec Králové","site":"50002|resslova956/13"},{"code":null,"name":"赫拉德茨-克拉洛韦","street":"Resslova 956/13","postal_code":"500 02","city":"Hradec Králové","is_hq":false,"address":"Resslova 956/13, 500 02 Hradec Králové","site":"50002|resslova956/13"},{"code":null,"name":"新比良佐夫","street":"1. Máje 198","postal_code":"504 01","city":"Nový Bydžov","is_hq":false,"address":"1. Máje 198, 504 01 Nový Bydžov","site":"50401|1máje198"},{"code":null,"name":"赫鲁迪姆","street":"Za Pivovarem 611","postal_code":"537 01","city":"Chrudim","is_hq":false,"address":"Za Pivovarem 611, 537 01 Chrudim","site":"53701|zapivovarem611"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"CHRL","pl":"Chemiczne środki odladzające","en":"Chemical de-icing agents","zh":"化学除冰剂","cs":"Chemické rozmrazovací látky"},{"abbr":"IP","pl":"Procedura wewnętrzna (opracowana przez Centralne Laboratorium Drogowe)","en":"Internal procedure (test procedure prepared by the Central Road Laboratory)","zh":"内部程序（中央道路实验室编制的检测程序）","cs":"Interní postup (postup zkoušky zpracovaný Centrální silniční laboratoří)"},{"abbr":"TP 94","pl":"Warunki techniczne zatwierdzone przez Ministerstwo Transportu RC, Departament Dróg, 24.10.2013, nr 77/2016-120-TN/1, obowiązujące od 1.11.2013 – Ulepszanie gruntów","en":"Technical specifications approved by the Ministry of Transport of the Czech Republic, Roads Department, on 24 Oct 2013 under ref. 77/2016-120-TN/1, valid from 1 Nov 2013 – Soil treatment","zh":"捷克交通部道路司于2013年10月24日批准（文号77/2016-120-TN/1）、自2013年11月1日起生效的技术条件——土的改良","cs":"Technické podmínky schválené Ministerstvem dopravy ČR, Odborem pozemních komunikací dne 24. 10. 2013 pod č.j. 77/2016-120-TN/1 platné od 1. 11. 2013 - Úprava zemin"}],"scope_notes":[{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The laboratory is qualified to carry out standalone sampling.","zh":"实验室有能力独立开展采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."}],"source_lang":"cs","source_pdf_sha256":"8ec13cc3ba0fdef6295bede018eccf68210bc0d1605bbf39ec5a2ac9d50035f6","source_pdf_url":"https://www.cai.cz/OA/pdf/170_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"aaaee80ceb61635f5fbe25cf","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"1","test_object":"Grunty, materiały sypkie","test_object_en":"Soils, bulk materials","test_object_zh":"土、散体材料","test_object_cs":"Zeminy, sypaniny","methodology":"Statyczne badanie obciążeniowe płytą","methodology_en":"Static plate load test","methodology_zh":"静态平板荷载试验","methodology_cs":"Statická zatěžovací zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Statyczne badanie obciążeniowe płytą","reference":"ČSN 72 1006, příl. A, B, D","norm_bases":["ČSN 72 1006, příl. A, B, D"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, materiały sypkie Statyczne badanie obciążeniowe płytą Zeminy, sypaniny Statická zatěžovací zkouška ČSN 72 1006, příl. A, B, D Grunty, materialy sypkie Statyczne badanie obciazeniowe plyta Zeminy, sypaniny Staticka zatezovaci zkouska CSN 72 1006, pril. A, B, D","search_en":"Soils, bulk materials Static plate load test ČSN 72 1006, příl. A, B, D","search_zh":"土、散体材料 静态平板荷载试验 ČSN 72 1006, příl. A, B, D","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4474068e15ad30ccaca74272","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"1","test_object":"Grunty, materiały sypkie","test_object_en":"Soils, bulk materials","test_object_zh":"土、散体材料","test_object_cs":"Zeminy, sypaniny","methodology":"Statyczne badanie obciążeniowe płytą","methodology_en":"Static plate load test","methodology_zh":"静态平板荷载试验","methodology_cs":"Statická zatěžovací zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Statyczne badanie obciążeniowe płytą","reference":"ČSN 72 1006, příl. A, B, D","norm_bases":["ČSN 72 1006, příl. A, B, D"],"lab_section":"Chrudim","lab_section_en":"Chrudim","lab_section_zh":"赫鲁迪姆","lab_section_cs":"Chrudim","lab_address":"Za Pivovarem 611, 537 01 Chrudim","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, materiały sypkie Statyczne badanie obciążeniowe płytą Zeminy, sypaniny Statická zatěžovací zkouška ČSN 72 1006, příl. A, B, D Grunty, materialy sypkie Statyczne badanie obciazeniowe plyta Zeminy, sypaniny Staticka zatezovaci zkouska CSN 72 1006, pril. A, B, D","search_en":"Soils, bulk materials Static plate load test ČSN 72 1006, příl. A, B, D","search_zh":"土、散体材料 静态平板荷载试验 ČSN 72 1006, příl. A, B, D","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c1f66843677c92c134b0aed7","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"2","test_object":"Grunty, materiały sypkie, nawierzchnie i podłoże","test_object_en":"Soils, bulk materials, pavements and subgrade","test_object_zh":"土、散体材料、路面及路基","test_object_cs":"Zeminy, sypaniny, vozovky a podloží","methodology":"Udarowe badanie obciążeniowe lekką płytą dynamiczną","methodology_en":"Impact load test with light dynamic plate","methodology_zh":"轻型动力板冲击荷载试验","methodology_cs":"Rázová zatěžovací zkouška lehkou dynamickou deskou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Udarowe badanie obciążeniowe lekką płytą dynamiczną","reference":"ČSN 73 6192, skupina C","norm_bases":["ČSN 73 6192, skupina C"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, materiały sypkie, nawierzchnie i podłoże Udarowe badanie obciążeniowe lekką płytą dynamiczną Zeminy, sypaniny, vozovky a podloží Rázová zatěžovací zkouška lehkou dynamickou deskou ČSN 73 6192, skupina C Grunty, materialy sypkie, nawierzchnie i podloze Udarowe badanie obciazeniowe lekka plyta dynamiczna Zeminy, sypaniny, vozovky a podlozi Razova zatezovaci zkouska lehkou dynamickou deskou CSN 73 6192, skupina C","search_en":"Soils, bulk materials, pavements and subgrade Impact load test with light dynamic plate ČSN 73 6192, skupina C","search_zh":"土、散体材料、路面及路基 轻型动力板冲击荷载试验 ČSN 73 6192, skupina C","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"997f88026c548ddcd7e6e094","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"2","test_object":"Grunty, materiały sypkie, nawierzchnie i podłoże","test_object_en":"Soils, bulk materials, pavements and subgrade","test_object_zh":"土、散体材料、路面及路基","test_object_cs":"Zeminy, sypaniny, vozovky a podloží","methodology":"Udarowe badanie obciążeniowe lekką płytą dynamiczną","methodology_en":"Impact load test with light dynamic plate","methodology_zh":"轻型动力板冲击荷载试验","methodology_cs":"Rázová zatěžovací zkouška lehkou dynamickou deskou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Udarowe badanie obciążeniowe lekką płytą dynamiczną","reference":"ČSN 73 6192, skupina C","norm_bases":["ČSN 73 6192, skupina C"],"lab_section":"Chrudim","lab_section_en":"Chrudim","lab_section_zh":"赫鲁迪姆","lab_section_cs":"Chrudim","lab_address":"Za Pivovarem 611, 537 01 Chrudim","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, materiały sypkie, nawierzchnie i podłoże Udarowe badanie obciążeniowe lekką płytą dynamiczną Zeminy, sypaniny, vozovky a podloží Rázová zatěžovací zkouška lehkou dynamickou deskou ČSN 73 6192, skupina C Grunty, materialy sypkie, nawierzchnie i podloze Udarowe badanie obciazeniowe lekka plyta dynamiczna Zeminy, sypaniny, vozovky a podlozi Razova zatezovaci zkouska lehkou dynamickou deskou CSN 73 6192, skupina C","search_en":"Soils, bulk materials, pavements and subgrade Impact load test with light dynamic plate ČSN 73 6192, skupina C","search_zh":"土、散体材料、路面及路基 轻型动力板冲击荷载试验 ČSN 73 6192, skupina C","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"68b6dec5105b8c53678f854f","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"3","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie wilgotności metodą wagową","methodology_en":"Determination of water content by gravimetry","methodology_zh":"重量法含水率测定","methodology_cs":"Stanovení vlhkosti gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności metodą wagową","reference":"ČSN EN ISO 17892-1","norm_bases":["ČSN EN ISO 17892-1"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie wilgotności metodą wagową Zeminy Stanovení vlhkosti gravimetricky ČSN EN ISO 17892-1 Grunty Oznaczanie wilgotnosci metoda wagowa Zeminy Stanoveni vlhkosti gravimetricky CSN EN ISO 17892-1","search_en":"Soils Determination of water content by gravimetry ČSN EN ISO 17892-1","search_zh":"土 重量法含水率测定 ČSN EN ISO 17892-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1d5cb49f2207d68b540fe008","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"3","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie wilgotności metodą wagową","methodology_en":"Determination of water content by gravimetry","methodology_zh":"重量法含水率测定","methodology_cs":"Stanovení vlhkosti gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności metodą wagową","reference":"ČSN EN ISO 17892-1","norm_bases":["ČSN EN ISO 17892-1"],"lab_section":"Chrudim","lab_section_en":"Chrudim","lab_section_zh":"赫鲁迪姆","lab_section_cs":"Chrudim","lab_address":"Za Pivovarem 611, 537 01 Chrudim","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie wilgotności metodą wagową Zeminy Stanovení vlhkosti gravimetricky ČSN EN ISO 17892-1 Grunty Oznaczanie wilgotnosci metoda wagowa Zeminy Stanoveni vlhkosti gravimetricky CSN EN ISO 17892-1","search_en":"Soils Determination of water content by gravimetry ČSN EN ISO 17892-1","search_zh":"土 重量法含水率测定 ČSN EN ISO 17892-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e196f4ecdadce1e4c08e3d1b","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"4","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie granicy plastyczności","methodology_en":"Determination of plastic limit","methodology_zh":"塑限测定","methodology_cs":"Stanovení meze plasticity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie granicy plastyczności","reference":"ČSN 72 1013:1967; ČSN EN ISO 17892-12, čl. 5.5","norm_bases":["ČSN 72 1013:1967","ČSN EN ISO 17892-12, čl. 5.5"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie granicy plastyczności Zeminy Stanovení meze plasticity ČSN 72 1013:1967; ČSN EN ISO 17892-12, čl. 5.5 Grunty Oznaczanie granicy plastycznosci Zeminy Stanoveni meze plasticity CSN 72 1013:1967; CSN EN ISO 17892-12, cl. 5.5","search_en":"Soils Determination of plastic limit ČSN 72 1013:1967; ČSN EN ISO 17892-12, čl. 5.5","search_zh":"土 塑限测定 ČSN 72 1013:1967; ČSN EN ISO 17892-12, čl. 5.5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"58f304662f96accb99e3e9f5","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"5","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie granicy płynności","methodology_en":"Determination of liquid limit","methodology_zh":"液限测定","methodology_cs":"Stanovení meze tekutosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie granicy płynności","reference":"ČSN 72 1014:1967; ČSN EN ISO 17892-12, čl. 5.4","norm_bases":["ČSN 72 1014:1967","ČSN EN ISO 17892-12, čl. 5.4"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie granicy płynności Zeminy Stanovení meze tekutosti ČSN 72 1014:1967; ČSN EN ISO 17892-12, čl. 5.4 Grunty Oznaczanie granicy plynnosci Zeminy Stanoveni meze tekutosti CSN 72 1014:1967; CSN EN ISO 17892-12, cl. 5.4","search_en":"Soils Determination of liquid limit ČSN 72 1014:1967; ČSN EN ISO 17892-12, čl. 5.4","search_zh":"土 液限测定 ČSN 72 1014:1967; ČSN EN ISO 17892-12, čl. 5.4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"23abc9b91b16f0cc762c938a","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"6","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie gęstości objętościowej odniesienia i wilgotności – Proctor standardowy","methodology_en":"Determination of reference density and water content – standard Proctor","methodology_zh":"参考密度和含水率测定 – 标准普氏击实","methodology_cs":"Stanovení srovnávací objemové hmotnosti a vlhkosti – Proctor standard","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej odniesienia i wilgotności – Proctor standardowy","reference":"ČSN EN 13286-2, mimo čl. 7.3","norm_bases":["ČSN EN 13286-2, mimo čl. 7.3"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie gęstości objętościowej odniesienia i wilgotności – Proctor standardowy Zeminy Stanovení srovnávací objemové hmotnosti a vlhkosti – Proctor standard ČSN EN 13286-2, mimo čl. 7.3 Grunty Oznaczanie gestosci objetosciowej odniesienia i wilgotnosci – Proctor standardowy Zeminy Stanoveni srovnavaci objemove hmotnosti a vlhkosti – Proctor standard CSN EN 13286-2, mimo cl. 7.3","search_en":"Soils Determination of reference density and water content – standard Proctor ČSN EN 13286-2, mimo čl. 7.3","search_zh":"土 参考密度和含水率测定 – 标准普氏击实 ČSN EN 13286-2, mimo čl. 7.3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6871c861c344c0ce8fde06e8","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"7","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie gęstości objętościowej odniesienia i wilgotności – Proctor zmodyfikowany","methodology_en":"Determination of reference density and water content – modified Proctor","methodology_zh":"参考密度和含水率测定 – 修正普氏击实","methodology_cs":"Stanovení srovnávací objemové hmotnosti a vlhkosti – Proctor modifikovaný","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej odniesienia i wilgotności – Proctor zmodyfikowany","reference":"ČSN EN 13286-2, mimo čl. 7.6","norm_bases":["ČSN EN 13286-2, mimo čl. 7.6"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie gęstości objętościowej odniesienia i wilgotności – Proctor zmodyfikowany Zeminy Stanovení srovnávací objemové hmotnosti a vlhkosti – Proctor modifikovaný ČSN EN 13286-2, mimo čl. 7.6 Grunty Oznaczanie gestosci objetosciowej odniesienia i wilgotnosci – Proctor zmodyfikowany Zeminy Stanoveni srovnavaci objemove hmotnosti a vlhkosti – Proctor modifikovany CSN EN 13286-2, mimo cl. 7.6","search_en":"Soils Determination of reference density and water content – modified Proctor ČSN EN 13286-2, mimo čl. 7.6","search_zh":"土 参考密度和含水率测定 – 修正普氏击实 ČSN EN 13286-2, mimo čl. 7.6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a2155e6affc33358337fed61","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"8","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie gęstości objętościowej i wskaźnika zagęszczenia – metody wykopu (dołka)","methodology_en":"Determination of bulk density and degree of compaction – pit methods","methodology_zh":"密度及压实度测定 – 坑测法","methodology_cs":"Stanovení objemové hmotnosti a míry zhutnění – jamkové metody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej i wskaźnika zagęszczenia – metody wykopu (dołka)","reference":"ČSN 72 1010, čl. 35 až 44","norm_bases":["ČSN 72 1010, čl. 35 až 44"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie gęstości objętościowej i wskaźnika zagęszczenia – metody wykopu (dołka) Zeminy Stanovení objemové hmotnosti a míry zhutnění – jamkové metody ČSN 72 1010, čl. 35 až 44 Grunty Oznaczanie gestosci objetosciowej i wskaznika zageszczenia – metody wykopu (dolka) Zeminy Stanoveni objemove hmotnosti a miry zhutneni – jamkove metody CSN 72 1010, cl. 35 az 44","search_en":"Soils Determination of bulk density and degree of compaction – pit methods ČSN 72 1010, čl. 35 až 44","search_zh":"土 密度及压实度测定 – 坑测法 ČSN 72 1010, čl. 35 až 44","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8716baf83fab55aa8951709a","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"8","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie gęstości objętościowej i wskaźnika zagęszczenia – metody wykopu (dołka)","methodology_en":"Determination of bulk density and degree of compaction – pit methods","methodology_zh":"密度及压实度测定 – 坑测法","methodology_cs":"Stanovení objemové hmotnosti a míry zhutnění – jamkové metody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej i wskaźnika zagęszczenia – metody wykopu (dołka)","reference":"ČSN 72 1010, čl. 35 až 44","norm_bases":["ČSN 72 1010, čl. 35 až 44"],"lab_section":"Chrudim","lab_section_en":"Chrudim","lab_section_zh":"赫鲁迪姆","lab_section_cs":"Chrudim","lab_address":"Za Pivovarem 611, 537 01 Chrudim","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie gęstości objętościowej i wskaźnika zagęszczenia – metody wykopu (dołka) Zeminy Stanovení objemové hmotnosti a míry zhutnění – jamkové metody ČSN 72 1010, čl. 35 až 44 Grunty Oznaczanie gestosci objetosciowej i wskaznika zageszczenia – metody wykopu (dolka) Zeminy Stanoveni objemove hmotnosti a miry zhutneni – jamkove metody CSN 72 1010, cl. 35 az 44","search_en":"Soils Determination of bulk density and degree of compaction – pit methods ČSN 72 1010, čl. 35 až 44","search_zh":"土 密度及压实度测定 – 坑测法 ČSN 72 1010, čl. 35 až 44","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4fb9239c20d2d8d9f30dd94a","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"9","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie wskaźnika nośności gruntów (CBR, IBI)","methodology_en":"Determination of bearing ratio of soils (CBR, IBI)","methodology_zh":"土承载比测定（CBR、IBI）","methodology_cs":"Stanovení poměru únosnosti zemin (CBR, IBI)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wskaźnika nośności gruntów (CBR, IBI)","reference":"ČSN EN 13286-47","norm_bases":["ČSN EN 13286-47"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie wskaźnika nośności gruntów (CBR, IBI) Zeminy Stanovení poměru únosnosti zemin (CBR, IBI) ČSN EN 13286-47 Grunty Oznaczanie wskaznika nosnosci gruntow (CBR, IBI) Zeminy Stanoveni pomeru unosnosti zemin (CBR, IBI) CSN EN 13286-47","search_en":"Soils Determination of bearing ratio of soils (CBR, IBI) ČSN EN 13286-47","search_zh":"土 土承载比测定（CBR、IBI） ČSN EN 13286-47","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f2a70605c81c1db9852a7754","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"10","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"颗粒级配测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN 72 1017:1995; ČSN EN ISO 17892-4","norm_bases":["ČSN 72 1017:1995","ČSN EN ISO 17892-4"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie uziarnienia Zeminy Stanovení zrnitosti ČSN 72 1017:1995; ČSN EN ISO 17892-4 Grunty Oznaczanie uziarnienia Zeminy Stanoveni zrnitosti CSN 72 1017:1995; CSN EN ISO 17892-4","search_en":"Soils Determination of particle size distribution ČSN 72 1017:1995; ČSN EN ISO 17892-4","search_zh":"土 颗粒级配测定 ČSN 72 1017:1995; ČSN EN ISO 17892-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2d97ab9890fde8f753311a03","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"11","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie zawartości domieszek organicznych","methodology_en":"Determination of organic admixture content","methodology_zh":"有机杂质含量测定","methodology_cs":"Stanovení obsahu organických přimíšenin","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości domieszek organicznych","reference":"IP 31/10 (B. Klobouček a kolektiv - Silniční laboratoř, SNTL 1979, čl. 1.2.14)","norm_bases":["IP 31/10","B. Klobouček a kolektiv - Silniční laboratoř, SNTL 1979"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie zawartości domieszek organicznych Zeminy Stanovení obsahu organických přimíšenin IP 31/10 (B. Klobouček a kolektiv - Silniční laboratoř, SNTL 1979, čl. 1.2.14) Grunty Oznaczanie zawartosci domieszek organicznych Zeminy Stanoveni obsahu organickych primisenin IP 31/10 (B. Kloboucek a kolektiv - Silnicni laborator, SNTL 1979, cl. 1.2.14)","search_en":"Soils Determination of organic admixture content IP 31/10 (B. Klobouček a kolektiv - Silniční laboratoř, SNTL 1979, čl. 1.2.14)","search_zh":"土 有机杂质含量测定 IP 31/10 (B. Klobouček a kolektiv - Silniční laboratoř, SNTL 1979, čl. 1.2.14)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cd2e0418bb95725be3306d7d","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"12","test_object":"Grunty","test_object_en":"Soils","test_object_zh":"土","test_object_cs":"Zeminy","methodology":"Oznaczanie stopnia zagęszczenia (relatywnego)","methodology_en":"Determination of relative density","methodology_zh":"相对密实度测定","methodology_cs":"Stanovení relativní ulehlosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stopnia zagęszczenia (relatywnego)","reference":"ČSN 72 1018","norm_bases":["ČSN 72 1018"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty Oznaczanie stopnia zagęszczenia (relatywnego) Zeminy Stanovení relativní ulehlosti ČSN 72 1018 Grunty Oznaczanie stopnia zageszczenia (relatywnego) Zeminy Stanoveni relativni ulehlosti CSN 72 1018","search_en":"Soils Determination of relative density ČSN 72 1018","search_zh":"土 相对密实度测定 ČSN 72 1018","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d5bae9a97f532fc1ac63185f","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"13","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"颗粒级配测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie uziarnienia Kamenivo Stanovení zrnitosti ČSN EN 933-1 Kruszywo Oznaczanie uziarnienia Kamenivo Stanoveni zrnitosti CSN EN 933-1","search_en":"Aggregate Determination of particle size distribution ČSN EN 933-1","search_zh":"集料 颗粒级配测定 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"545533f32d27ed47a3de7872","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"13","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"颗粒级配测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":"Chrudim","lab_section_en":"Chrudim","lab_section_zh":"赫鲁迪姆","lab_section_cs":"Chrudim","lab_address":"Za Pivovarem 611, 537 01 Chrudim","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie uziarnienia Kamenivo Stanovení zrnitosti ČSN EN 933-1 Kruszywo Oznaczanie uziarnienia Kamenivo Stanoveni zrnitosti CSN EN 933-1","search_en":"Aggregate Determination of particle size distribution ČSN EN 933-1","search_zh":"集料 颗粒级配测定 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"170ae8cbb44fdf5b602fb333","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"14","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie udziału ziaren o wskaźniku kształtu 3 i większym","methodology_en":"Determination of proportion of particles with shape index 3 and greater","methodology_zh":"形状指数3及以上颗粒比例测定","methodology_cs":"Stanovení podílu zrn s indexem 3 a větším","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie udziału ziaren o wskaźniku kształtu 3 i większym","reference":"ČSN EN 933-4","norm_bases":["ČSN EN 933-4"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie udziału ziaren o wskaźniku kształtu 3 i większym Kamenivo Stanovení podílu zrn s indexem 3 a větším ČSN EN 933-4 Kruszywo Oznaczanie udzialu ziaren o wskazniku ksztaltu 3 i wiekszym Kamenivo Stanoveni podilu zrn s indexem 3 a vetsim CSN EN 933-4","search_en":"Aggregate Determination of proportion of particles with shape index 3 and greater ČSN EN 933-4","search_zh":"集料 形状指数3及以上颗粒比例测定 ČSN EN 933-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"650dc4b5ffded08cde8d077d","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"14","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie udziału ziaren o wskaźniku kształtu 3 i większym","methodology_en":"Determination of proportion of particles with shape index 3 and greater","methodology_zh":"形状指数3及以上颗粒比例测定","methodology_cs":"Stanovení podílu zrn s indexem 3 a větším","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie udziału ziaren o wskaźniku kształtu 3 i większym","reference":"ČSN EN 933-4","norm_bases":["ČSN EN 933-4"],"lab_section":"Chrudim","lab_section_en":"Chrudim","lab_section_zh":"赫鲁迪姆","lab_section_cs":"Chrudim","lab_address":"Za Pivovarem 611, 537 01 Chrudim","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie udziału ziaren o wskaźniku kształtu 3 i większym Kamenivo Stanovení podílu zrn s indexem 3 a větším ČSN EN 933-4 Kruszywo Oznaczanie udzialu ziaren o wskazniku ksztaltu 3 i wiekszym Kamenivo Stanoveni podilu zrn s indexem 3 a vetsim CSN EN 933-4","search_en":"Aggregate Determination of proportion of particles with shape index 3 and greater ČSN EN 933-4","search_zh":"集料 形状指数3及以上颗粒比例测定 ČSN EN 933-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4c9a0b6f2d273399981f7fa4","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"15","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie wskaźnika piaskowego","methodology_en":"Determination of sand equivalent","methodology_zh":"砂当量测定","methodology_cs":"Stanovení ekvivalentu písku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wskaźnika piaskowego","reference":"ČSN EN 933-8+A1","norm_bases":["ČSN EN 933-8+A1"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie wskaźnika piaskowego Kamenivo Stanovení ekvivalentu písku ČSN EN 933-8+A1 Kruszywo Oznaczanie wskaznika piaskowego Kamenivo Stanoveni ekvivalentu pisku CSN EN 933-8+A1","search_en":"Aggregate Determination of sand equivalent ČSN EN 933-8+A1","search_zh":"集料 砂当量测定 ČSN EN 933-8+A1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3c426ef585002e3ef15e19cd","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"16","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Ocena pyłów – badanie błękitem metylenowym","methodology_en":"Assessment of fines – methylene blue test","methodology_zh":"细颗粒评定 – 亚甲蓝试验","methodology_cs":"Posouzení jemných částic – zkouška methylenovou modří","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ocena pyłów – badanie błękitem metylenowym","reference":"ČSN EN 933-9","norm_bases":["ČSN EN 933-9"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Ocena pyłów – badanie błękitem metylenowym Kamenivo Posouzení jemných částic – zkouška methylenovou modří ČSN EN 933-9 Kruszywo Ocena pylow – badanie blekitem metylenowym Kamenivo Posouzeni jemnych castic – zkouska methylenovou modri CSN EN 933-9","search_en":"Aggregate Assessment of fines – methylene blue test ČSN EN 933-9","search_zh":"集料 细颗粒评定 – 亚甲蓝试验 ČSN EN 933-9","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9a3189af3d5e5a05def39d57","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"17","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie wilgotności metodą wagową","methodology_en":"Determination of water content by gravimetry","methodology_zh":"重量法含水率测定","methodology_cs":"Stanovení vlhkosti gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności metodą wagową","reference":"ČSN EN 1097-5","norm_bases":["ČSN EN 1097-5"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie wilgotności metodą wagową Kamenivo Stanovení vlhkosti gravimetricky ČSN EN 1097-5 Kruszywo Oznaczanie wilgotnosci metoda wagowa Kamenivo Stanoveni vlhkosti gravimetricky CSN EN 1097-5","search_en":"Aggregate Determination of water content by gravimetry ČSN EN 1097-5","search_zh":"集料 重量法含水率测定 ČSN EN 1097-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"83dedc4a4595775c5b9bdb0e","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"17","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie wilgotności metodą wagową","methodology_en":"Determination of water content by gravimetry","methodology_zh":"重量法含水率测定","methodology_cs":"Stanovení vlhkosti gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności metodą wagową","reference":"ČSN EN 1097-5","norm_bases":["ČSN EN 1097-5"],"lab_section":"Chrudim","lab_section_en":"Chrudim","lab_section_zh":"赫鲁迪姆","lab_section_cs":"Chrudim","lab_address":"Za Pivovarem 611, 537 01 Chrudim","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie wilgotności metodą wagową Kamenivo Stanovení vlhkosti gravimetricky ČSN EN 1097-5 Kruszywo Oznaczanie wilgotnosci metoda wagowa Kamenivo Stanoveni vlhkosti gravimetricky CSN EN 1097-5","search_en":"Aggregate Determination of water content by gravimetry ČSN EN 1097-5","search_zh":"集料 重量法含水率测定 ČSN EN 1097-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5964400543d7b6bc50c4161a","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"18","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie gęstości i nasiąkliwości","methodology_en":"Determination of particle density and water absorption","methodology_zh":"颗粒密度及吸水率测定","methodology_cs":"Stanovení objemové hmotnosti a nasákavosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości i nasiąkliwości","reference":"ČSN EN 1097-6","norm_bases":["ČSN EN 1097-6"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie gęstości i nasiąkliwości Kamenivo Stanovení objemové hmotnosti a nasákavosti ČSN EN 1097-6 Kruszywo Oznaczanie gestosci i nasiakliwosci Kamenivo Stanoveni objemove hmotnosti a nasakavosti CSN EN 1097-6","search_en":"Aggregate Determination of particle density and water absorption ČSN EN 1097-6","search_zh":"集料 颗粒密度及吸水率测定 ČSN EN 1097-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0ce5a0cc495393f9cb2980bb","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"19","test_object":"Wypełniacz","test_object_en":"Filler","test_object_zh":"填料","test_object_cs":"Filer","methodology":"Oznaczanie gęstości właściwej","methodology_en":"Determination of particle density","methodology_zh":"比重测定","methodology_cs":"Stanovení měrné hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości właściwej","reference":"ČSN EN 1097-7","norm_bases":["ČSN EN 1097-7"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wypełniacz Oznaczanie gęstości właściwej Filer Stanovení měrné hmotnosti ČSN EN 1097-7 Wypelniacz Oznaczanie gestosci wlasciwej Filer Stanoveni merne hmotnosti CSN EN 1097-7","search_en":"Filler Determination of particle density ČSN EN 1097-7","search_zh":"填料 比重测定 ČSN EN 1097-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f51cf35c2fede8b60a59226d","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"20","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie mrozoodporności","methodology_en":"Determination of resistance to freezing and thawing","methodology_zh":"抗冻性测定","methodology_cs":"Stanovení mrazuvzdornosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mrozoodporności","reference":"ČSN EN 1367-1","norm_bases":["ČSN EN 1367-1"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie mrozoodporności Kamenivo Stanovení mrazuvzdornosti ČSN EN 1367-1 Kruszywo Oznaczanie mrozoodpornosci Kamenivo Stanoveni mrazuvzdornosti CSN EN 1367-1","search_en":"Aggregate Determination of resistance to freezing and thawing ČSN EN 1367-1","search_zh":"集料 抗冻性测定 ČSN EN 1367-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d2e08dcb6bca4b9c81081898","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"21","test_object":"Asfalt","test_object_en":"Bitumen","test_object_zh":"沥青","test_object_cs":"Asfalt","methodology":"Oznaczanie penetracji igłą wraz z przygotowaniem próbek","methodology_en":"Determination of needle penetration, including sample preparation","methodology_zh":"针入度测定（含样品制备）","methodology_cs":"Stanovení penetrace jehlou, včetně přípravy vzorků","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie penetracji igłą wraz z przygotowaniem próbek","reference":"ČSN EN 1426; ČSN EN 12594","norm_bases":["ČSN EN 1426","ČSN EN 12594"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Asfalt Oznaczanie penetracji igłą wraz z przygotowaniem próbek Asfalt Stanovení penetrace jehlou, včetně přípravy vzorků ČSN EN 1426; ČSN EN 12594 Asfalt Oznaczanie penetracji igla wraz z przygotowaniem probek Asfalt Stanoveni penetrace jehlou, vcetne pripravy vzorku CSN EN 1426; CSN EN 12594","search_en":"Bitumen Determination of needle penetration, including sample preparation ČSN EN 1426; ČSN EN 12594","search_zh":"沥青 针入度测定（含样品制备） ČSN EN 1426; ČSN EN 12594","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"60b99e824bb732d4a73c9a8b","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"22","test_object":"Asfalt","test_object_en":"Bitumen","test_object_zh":"沥青","test_object_cs":"Asfalt","methodology":"Oznaczanie temperatury mięknienia – metoda Pierścień i Kula, wraz z przygotowaniem próbek","methodology_en":"Determination of softening point – ring and ball method, including sample preparation","methodology_zh":"软化点测定 – 环球法（含样品制备）","methodology_cs":"Stanovení bodu měknutí – metoda kroužek a kulička, včetně přípravy vzorků","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury mięknienia – metoda Pierścień i Kula, wraz z przygotowaniem próbek","reference":"ČSN EN 1427; ČSN EN 12594","norm_bases":["ČSN EN 1427","ČSN EN 12594"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Asfalt Oznaczanie temperatury mięknienia – metoda Pierścień i Kula, wraz z przygotowaniem próbek Asfalt Stanovení bodu měknutí – metoda kroužek a kulička, včetně přípravy vzorků ČSN EN 1427; ČSN EN 12594 Asfalt Oznaczanie temperatury mieknienia – metoda Pierscien i Kula, wraz z przygotowaniem probek Asfalt Stanoveni bodu meknuti – metoda krouzek a kulicka, vcetne pripravy vzorku CSN EN 1427; CSN EN 12594","search_en":"Bitumen Determination of softening point – ring and ball method, including sample preparation ČSN EN 1427; ČSN EN 12594","search_zh":"沥青 软化点测定 – 环球法（含样品制备） ČSN EN 1427; ČSN EN 12594","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4a2145bcd54eb9d185676120","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"23","test_object":"Asfalt","test_object_en":"Bitumen","test_object_zh":"沥青","test_object_cs":"Asfalt","methodology":"Oznaczanie przyczepności lepiszczy asfaltowych do kruszywa","methodology_en":"Determination of adhesion of bituminous binders to aggregate","methodology_zh":"沥青结合料与集料粘附性测定","methodology_cs":"Stanovení přilnavosti asfaltových pojiv ke kamenivu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przyczepności lepiszczy asfaltowych do kruszywa","reference":"ČSN 73 6161","norm_bases":["ČSN 73 6161"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Asfalt Oznaczanie przyczepności lepiszczy asfaltowych do kruszywa Asfalt Stanovení přilnavosti asfaltových pojiv ke kamenivu ČSN 73 6161 Asfalt Oznaczanie przyczepnosci lepiszczy asfaltowych do kruszywa Asfalt Stanoveni prilnavosti asfaltovych pojiv ke kamenivu CSN 73 6161","search_en":"Bitumen Determination of adhesion of bituminous binders to aggregate ČSN 73 6161","search_zh":"沥青 沥青结合料与集料粘附性测定 ČSN 73 6161","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"118a022ad9169f030d9cc00b","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"24","test_object":"Mieszanka asfaltowa, warstwa asfaltowa","test_object_en":"Asphalt mixture, asphalt layer","test_object_zh":"沥青混合料、沥青层","test_object_cs":"Asfaltová směs, asfaltová vrstva","methodology":"Oznaczanie gęstości objętościowej i zawartości wolnych przestrzeni","methodology_en":"Determination of density and air voids content","methodology_zh":"密度及空隙率测定","methodology_cs":"Stanovení objemové hmotnosti a mezerovitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej i zawartości wolnych przestrzeni","reference":"ČSN 73 6160:1986, čl. 64 až 89; ČSN EN 12697-5; ČSN EN 12697-6; ČSN EN 12697-8; ČSN EN 12697-29; ČSN EN 12697-30","norm_bases":["ČSN 73 6160:1986, čl. 64 až 89","ČSN EN 12697-5","ČSN EN 12697-6","ČSN EN 12697-8","ČSN EN 12697-29","ČSN EN 12697-30"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa, warstwa asfaltowa Oznaczanie gęstości objętościowej i zawartości wolnych przestrzeni Asfaltová směs, asfaltová vrstva Stanovení objemové hmotnosti a mezerovitosti ČSN 73 6160:1986, čl. 64 až 89; ČSN EN 12697-5; ČSN EN 12697-6; ČSN EN 12697-8; ČSN EN 12697-29; ČSN EN 12697-30 Mieszanka asfaltowa, warstwa asfaltowa Oznaczanie gestosci objetosciowej i zawartosci wolnych przestrzeni Asfaltova smes, asfaltova vrstva Stanoveni objemove hmotnosti a mezerovitosti CSN 73 6160:1986, cl. 64 az 89; CSN EN 12697-5; CSN EN 12697-6; CSN EN 12697-8; CSN EN 12697-29; CSN EN 12697-30","search_en":"Asphalt mixture, asphalt layer Determination of density and air voids content ČSN 73 6160:1986, čl. 64 až 89; ČSN EN 12697-5; ČSN EN 12697-6; ČSN EN 12697-8; ČSN EN 12697-29; ČSN EN 12697-30","search_zh":"沥青混合料、沥青层 密度及空隙率测定 ČSN 73 6160:1986, čl. 64 až 89; ČSN EN 12697-5; ČSN EN 12697-6; ČSN EN 12697-8; ČSN EN 12697-29; ČSN EN 12697-30","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9f4ccf6c17444d8fae352fd0","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"25","test_object":"Warstwa asfaltowa","test_object_en":"Asphalt layer","test_object_zh":"沥青层","test_object_cs":"Asfaltová vrstva","methodology":"Oznaczanie wskaźnika zagęszczenia na odwiertach","methodology_en":"Determination of degree of compaction on cores","methodology_zh":"芯样压实度测定","methodology_cs":"Stanovení míry zhutnění na vývrtech","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wskaźnika zagęszczenia na odwiertach","reference":"ČSN 73 6160, čl. 7.2 a), c)","norm_bases":["ČSN 73 6160, čl. 7.2 a), c)"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwa asfaltowa Oznaczanie wskaźnika zagęszczenia na odwiertach Asfaltová vrstva Stanovení míry zhutnění na vývrtech ČSN 73 6160, čl. 7.2 a), c) Warstwa asfaltowa Oznaczanie wskaznika zageszczenia na odwiertach Asfaltova vrstva Stanoveni miry zhutneni na vyvrtech CSN 73 6160, cl. 7.2 a), c)","search_en":"Asphalt layer Determination of degree of compaction on cores ČSN 73 6160, čl. 7.2 a), c)","search_zh":"沥青层 芯样压实度测定 ČSN 73 6160, čl. 7.2 a), c)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f54b4864af3d4308839912a5","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"26","test_object":"Mieszanka asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie zawartości lepiszcza rozpuszczalnego","methodology_en":"Determination of soluble binder content","methodology_zh":"可溶结合料含量测定","methodology_cs":"Stanovení obsahu rozpustného pojiva","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości lepiszcza rozpuszczalnego","reference":"ČSN EN 12697-1","norm_bases":["ČSN EN 12697-1"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa Oznaczanie zawartości lepiszcza rozpuszczalnego Asfaltová směs Stanovení obsahu rozpustného pojiva ČSN EN 12697-1 Mieszanka asfaltowa Oznaczanie zawartosci lepiszcza rozpuszczalnego Asfaltova smes Stanoveni obsahu rozpustneho pojiva CSN EN 12697-1","search_en":"Asphalt mixture Determination of soluble binder content ČSN EN 12697-1","search_zh":"沥青混合料 可溶结合料含量测定 ČSN EN 12697-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"668a57a1efbf95171e83e8c7","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"27","test_object":"Mieszanka asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"颗粒级配测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN EN 12697-2","norm_bases":["ČSN EN 12697-2"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa Oznaczanie uziarnienia Asfaltová směs Stanovení zrnitosti ČSN EN 12697-2 Mieszanka asfaltowa Oznaczanie uziarnienia Asfaltova smes Stanoveni zrnitosti CSN EN 12697-2","search_en":"Asphalt mixture Determination of particle size distribution ČSN EN 12697-2","search_zh":"沥青混合料 颗粒级配测定 ČSN EN 12697-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e6a6e33d8af7b09016af63fb","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"28","test_object":"Warstwa asfaltowa","test_object_en":"Asphalt layer","test_object_zh":"沥青层","test_object_cs":"Asfaltová vrstva","methodology":"Oznaczanie grubości na odwiertach","methodology_en":"Determination of thickness on cores","methodology_zh":"芯样厚度测定","methodology_cs":"Stanovení tloušťky na vývrtech","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie grubości na odwiertach","reference":"ČSN EN 12697-36, čl. 1, 2.1 až 2.3, 3, 4.1, 5, 6","norm_bases":["ČSN EN 12697-36, čl. 1, 2.1 až 2.3, 3, 4.1, 5, 6"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwa asfaltowa Oznaczanie grubości na odwiertach Asfaltová vrstva Stanovení tloušťky na vývrtech ČSN EN 12697-36, čl. 1, 2.1 až 2.3, 3, 4.1, 5, 6 Warstwa asfaltowa Oznaczanie grubosci na odwiertach Asfaltova vrstva Stanoveni tloustky na vyvrtech CSN EN 12697-36, cl. 1, 2.1 az 2.3, 3, 4.1, 5, 6","search_en":"Asphalt layer Determination of thickness on cores ČSN EN 12697-36, čl. 1, 2.1 až 2.3, 3, 4.1, 5, 6","search_zh":"沥青层 芯样厚度测定 ČSN EN 12697-36, čl. 1, 2.1 až 2.3, 3, 4.1, 5, 6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c78ca121545e8624a408d487","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"29","test_object":"Mieszanka asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Badanie spływności lepiszcza – metoda Schellenberga","methodology_en":"Binder drainage test – Schellenberg method","methodology_zh":"结合料析漏试验 – Schellenberg法","methodology_cs":"Zkouška stékavosti pojiva – Schellenbergova metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie spływności lepiszcza – metoda Schellenberga","reference":"ČSN EN 12697-18","norm_bases":["ČSN EN 12697-18"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa Badanie spływności lepiszcza – metoda Schellenberga Asfaltová směs Zkouška stékavosti pojiva – Schellenbergova metoda ČSN EN 12697-18 Mieszanka asfaltowa Badanie splywnosci lepiszcza – metoda Schellenberga Asfaltova smes Zkouska stekavosti pojiva – Schellenbergova metoda CSN EN 12697-18","search_en":"Asphalt mixture Binder drainage test – Schellenberg method ČSN EN 12697-18","search_zh":"沥青混合料 结合料析漏试验 – Schellenberg法 ČSN EN 12697-18","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cc7ea98429c096e7a370ccc7","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"30","test_object":"Warstwa asfaltowa","test_object_en":"Asphalt layer","test_object_zh":"沥青层","test_object_cs":"Asfaltová vrstva","methodology":"Badanie ścinania – połączenie warstw asfaltowych metodą Leutnera","methodology_en":"Shear test – bond between asphalt layers according to Leutner","methodology_zh":"Leutner剪切试验 – 沥青层间粘结","methodology_cs":"Smyková zkouška – spojení asfaltových vrstev podle Leutnera","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie ścinania – połączenie warstw asfaltowych metodą Leutnera","reference":"ČSN 73 6160, čl. 7.3","norm_bases":["ČSN 73 6160, čl. 7.3"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwa asfaltowa Badanie ścinania – połączenie warstw asfaltowych metodą Leutnera Asfaltová vrstva Smyková zkouška – spojení asfaltových vrstev podle Leutnera ČSN 73 6160, čl. 7.3 Warstwa asfaltowa Badanie scinania – polaczenie warstw asfaltowych metoda Leutnera Asfaltova vrstva Smykova zkouska – spojeni asfaltovych vrstev podle Leutnera CSN 73 6160, cl. 7.3","search_en":"Asphalt layer Shear test – bond between asphalt layers according to Leutner ČSN 73 6160, čl. 7.3","search_zh":"沥青层 Leutner剪切试验 – 沥青层间粘结 ČSN 73 6160, čl. 7.3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"365ede8c033b4098ed58bb6b","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"31","test_object":"Mieszanka asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie wrażliwości na działanie wody","methodology_en":"Determination of water sensitivity","methodology_zh":"水敏感性测定","methodology_cs":"Stanovení odolnosti vůči vodě","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wrażliwości na działanie wody","reference":"ČSN EN 12697-12","norm_bases":["ČSN EN 12697-12"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa Oznaczanie wrażliwości na działanie wody Asfaltová směs Stanovení odolnosti vůči vodě ČSN EN 12697-12 Mieszanka asfaltowa Oznaczanie wrazliwosci na dzialanie wody Asfaltova smes Stanoveni odolnosti vuci vode CSN EN 12697-12","search_en":"Asphalt mixture Determination of water sensitivity ČSN EN 12697-12","search_zh":"沥青混合料 水敏感性测定 ČSN EN 12697-12","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5fc00bb4ef79187f91bde6ba","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"32","test_object":"Mieszanka asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Oznaczanie wytrzymałości na rozciąganie pośrednie","methodology_en":"Determination of indirect tensile strength","methodology_zh":"间接拉伸强度测定","methodology_cs":"Stanovení pevnosti v příčném tahu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na rozciąganie pośrednie","reference":"ČSN EN 12697-23","norm_bases":["ČSN EN 12697-23"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa Oznaczanie wytrzymałości na rozciąganie pośrednie Asfaltová směs Stanovení pevnosti v příčném tahu ČSN EN 12697-23 Mieszanka asfaltowa Oznaczanie wytrzymalosci na rozciaganie posrednie Asfaltova smes Stanoveni pevnosti v pricnem tahu CSN EN 12697-23","search_en":"Asphalt mixture Determination of indirect tensile strength ČSN EN 12697-23","search_zh":"沥青混合料 间接拉伸强度测定 ČSN EN 12697-23","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"23a5aeb5726d73f91a364ccd","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"33","test_object":"Grunty ulepszone spoiwem","test_object_en":"Soils improved with binder","test_object_zh":"结合料改良土","test_object_cs":"Zeminy zlepšené pojivem","methodology":"Badanie równomierności i głębokości wymieszania","methodology_en":"Test of uniformity and depth of mixing","methodology_zh":"拌和均匀性及深度试验","methodology_cs":"Zkouška stejnoměrnosti a hloubky promísení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie równomierności i głębokości wymieszania","reference":"ČSN 73 6125:1994, příl. A.6; TP 94:2013, kap. 7.2","norm_bases":["ČSN 73 6125:1994, příl. A.6","TP 94:2013, kap. 7.2"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty ulepszone spoiwem Badanie równomierności i głębokości wymieszania Zeminy zlepšené pojivem Zkouška stejnoměrnosti a hloubky promísení ČSN 73 6125:1994, příl. A.6; TP 94:2013, kap. 7.2 Grunty ulepszone spoiwem Badanie rownomiernosci i glebokosci wymieszania Zeminy zlepsene pojivem Zkouska stejnomernosti a hloubky promiseni CSN 73 6125:1994, pril. A.6; TP 94:2013, kap. 7.2","search_en":"Soils improved with binder Test of uniformity and depth of mixing ČSN 73 6125:1994, příl. A.6; TP 94:2013, kap. 7.2","search_zh":"结合料改良土 拌和均匀性及深度试验 ČSN 73 6125:1994, příl. A.6; TP 94:2013, kap. 7.2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"16504c5729fa5d0c198dac00","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"33","test_object":"Grunty ulepszone spoiwem","test_object_en":"Soils improved with binder","test_object_zh":"结合料改良土","test_object_cs":"Zeminy zlepšené pojivem","methodology":"Badanie równomierności i głębokości wymieszania","methodology_en":"Test of uniformity and depth of mixing","methodology_zh":"拌和均匀性及深度试验","methodology_cs":"Zkouška stejnoměrnosti a hloubky promísení","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie równomierności i głębokości wymieszania","reference":"ČSN 73 6125:1994, příl. A.6; TP 94:2013, kap. 7.2","norm_bases":["ČSN 73 6125:1994, příl. A.6","TP 94:2013, kap. 7.2"],"lab_section":"Chrudim","lab_section_en":"Chrudim","lab_section_zh":"赫鲁迪姆","lab_section_cs":"Chrudim","lab_address":"Za Pivovarem 611, 537 01 Chrudim","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty ulepszone spoiwem Badanie równomierności i głębokości wymieszania Zeminy zlepšené pojivem Zkouška stejnoměrnosti a hloubky promísení ČSN 73 6125:1994, příl. A.6; TP 94:2013, kap. 7.2 Grunty ulepszone spoiwem Badanie rownomiernosci i glebokosci wymieszania Zeminy zlepsene pojivem Zkouska stejnomernosti a hloubky promiseni CSN 73 6125:1994, pril. A.6; TP 94:2013, kap. 7.2","search_en":"Soils improved with binder Test of uniformity and depth of mixing ČSN 73 6125:1994, příl. A.6; TP 94:2013, kap. 7.2","search_zh":"结合料改良土 拌和均匀性及深度试验 ČSN 73 6125:1994, příl. A.6; TP 94:2013, kap. 7.2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4ced6581101ded845fe808e","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"34","test_object":"Grunty ulepszone spoiwem","test_object_en":"Soils improved with binder","test_object_zh":"结合料改良土","test_object_cs":"Zeminy zlepšené pojivem","methodology":"Badanie dozowania spoiwa","methodology_en":"Binder dosage test","methodology_zh":"结合料掺量试验","methodology_cs":"Zkouška dávkování pojiva","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie dozowania spoiwa","reference":"TP 94:2013, kap. 7.2","norm_bases":["TP 94:2013, kap. 7.2"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty ulepszone spoiwem Badanie dozowania spoiwa Zeminy zlepšené pojivem Zkouška dávkování pojiva TP 94:2013, kap. 7.2 Grunty ulepszone spoiwem Badanie dozowania spoiwa Zeminy zlepsene pojivem Zkouska davkovani pojiva TP 94:2013, kap. 7.2","search_en":"Soils improved with binder Binder dosage test TP 94:2013, kap. 7.2","search_zh":"结合料改良土 结合料掺量试验 TP 94:2013, kap. 7.2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6b46ef87e4e3d9df9a4fe1ff","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"34","test_object":"Grunty ulepszone spoiwem","test_object_en":"Soils improved with binder","test_object_zh":"结合料改良土","test_object_cs":"Zeminy zlepšené pojivem","methodology":"Badanie dozowania spoiwa","methodology_en":"Binder dosage test","methodology_zh":"结合料掺量试验","methodology_cs":"Zkouška dávkování pojiva","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie dozowania spoiwa","reference":"TP 94:2013, kap. 7.2","norm_bases":["TP 94:2013, kap. 7.2"],"lab_section":"Chrudim","lab_section_en":"Chrudim","lab_section_zh":"赫鲁迪姆","lab_section_cs":"Chrudim","lab_address":"Za Pivovarem 611, 537 01 Chrudim","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty ulepszone spoiwem Badanie dozowania spoiwa Zeminy zlepšené pojivem Zkouška dávkování pojiva TP 94:2013, kap. 7.2 Grunty ulepszone spoiwem Badanie dozowania spoiwa Zeminy zlepsene pojivem Zkouska davkovani pojiva TP 94:2013, kap. 7.2","search_en":"Soils improved with binder Binder dosage test TP 94:2013, kap. 7.2","search_zh":"结合料改良土 结合料掺量试验 TP 94:2013, kap. 7.2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7557c596c4a181a6caca1ee7","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"35","test_object":"Warstwy izolacyjne, powłoki i powierzchnie betonu","test_object_en":"Insulating layers, coatings and concrete surfaces","test_object_zh":"防水层、涂层及混凝土表面","test_object_cs":"Izolační vrstvy, povlaky a povrchy betonů","methodology":"Oznaczanie przyczepności i wytrzymałości na rozciąganie","methodology_en":"Determination of adhesion and tensile strength","methodology_zh":"粘结力及抗拉强度测定","methodology_cs":"Stanovení přilnavosti a pevnosti v tahu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przyczepności i wytrzymałości na rozciąganie","reference":"ČSN 73 6242, příl. B","norm_bases":["ČSN 73 6242, příl. B"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwy izolacyjne, powłoki i powierzchnie betonu Oznaczanie przyczepności i wytrzymałości na rozciąganie Izolační vrstvy, povlaky a povrchy betonů Stanovení přilnavosti a pevnosti v tahu ČSN 73 6242, příl. B Warstwy izolacyjne, powloki i powierzchnie betonu Oznaczanie przyczepnosci i wytrzymalosci na rozciaganie Izolacni vrstvy, povlaky a povrchy betonu Stanoveni prilnavosti a pevnosti v tahu CSN 73 6242, pril. B","search_en":"Insulating layers, coatings and concrete surfaces Determination of adhesion and tensile strength ČSN 73 6242, příl. B","search_zh":"防水层、涂层及混凝土表面 粘结力及抗拉强度测定 ČSN 73 6242, příl. B","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"16da470e6f6bb921ecaae566","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"36","test_object":"Konstrukcje betonowe z warstwą uszczelniającą, powłoką lub izolacją","test_object_en":"Concrete structures with sealing layer, coating or waterproofing","test_object_zh":"带封闭层、涂层或防水层的混凝土结构","test_object_cs":"Betonové konstrukce opatřené pečetící vrstvou, nátěrem nebo izolací","methodology":"Badanie szczelności","methodology_en":"Impermeability test","methodology_zh":"抗渗试验","methodology_cs":"Zkouška nepropustnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie szczelności","reference":"ČSN 73 6242, příl. D","norm_bases":["ČSN 73 6242, příl. D"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Konstrukcje betonowe z warstwą uszczelniającą, powłoką lub izolacją Badanie szczelności Betonové konstrukce opatřené pečetící vrstvou, nátěrem nebo izolací Zkouška nepropustnosti ČSN 73 6242, příl. D Konstrukcje betonowe z warstwa uszczelniajaca, powloka lub izolacja Badanie szczelnosci Betonove konstrukce opatrene pecetici vrstvou, naterem nebo izolaci Zkouska nepropustnosti CSN 73 6242, pril. D","search_en":"Concrete structures with sealing layer, coating or waterproofing Impermeability test ČSN 73 6242, příl. D","search_zh":"带封闭层、涂层或防水层的混凝土结构 抗渗试验 ČSN 73 6242, příl. D","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1fd65b99172345582f510199","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"37","test_object":"Powierzchnia nawierzchni dróg i pomostów","test_object_en":"Surface of road pavements and bridge decks","test_object_zh":"路面及桥面表面","test_object_cs":"Povrch krytů vozovek a mostovek","methodology":"Oznaczanie makrotekstury","methodology_en":"Determination of macrotexture","methodology_zh":"宏观构造测定","methodology_cs":"Zjišťování makrotextury","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie makrotekstury","reference":"ČSN EN 13036-1","norm_bases":["ČSN EN 13036-1"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powierzchnia nawierzchni dróg i pomostów Oznaczanie makrotekstury Povrch krytů vozovek a mostovek Zjišťování makrotextury ČSN EN 13036-1 Powierzchnia nawierzchni drog i pomostow Oznaczanie makrotekstury Povrch krytu vozovek a mostovek Zjistovani makrotextury CSN EN 13036-1","search_en":"Surface of road pavements and bridge decks Determination of macrotexture ČSN EN 13036-1","search_zh":"路面及桥面表面 宏观构造测定 ČSN EN 13036-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"291e76dc07dffc39cbf87fb1","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"38","test_object":"Powierzchnia nawierzchni i warstw podbudowy dróg i pomostów","test_object_en":"Surface of pavements, base courses and bridge decks","test_object_zh":"路面、基层及桥面表面","test_object_cs":"Povrch krytů a podkladních vrstev vozovek a mostovek","methodology":"Pomiar nierówności podłużnej i poprzecznej łatą","methodology_en":"Measurement of longitudinal and transverse unevenness with a straightedge","methodology_zh":"直尺法纵向和横向平整度测量","methodology_cs":"Měření podélné a příčné nerovnosti latí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar nierówności podłużnej i poprzecznej łatą","reference":"ČSN 73 6175, kap. 3, 4 a 8","norm_bases":["ČSN 73 6175, kap. 3, 4 a 8"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powierzchnia nawierzchni i warstw podbudowy dróg i pomostów Pomiar nierówności podłużnej i poprzecznej łatą Povrch krytů a podkladních vrstev vozovek a mostovek Měření podélné a příčné nerovnosti latí ČSN 73 6175, kap. 3, 4 a 8 Powierzchnia nawierzchni i warstw podbudowy drog i pomostow Pomiar nierownosci podluznej i poprzecznej lata Povrch krytu a podkladnich vrstev vozovek a mostovek Mereni podelne a pricne nerovnosti lati CSN 73 6175, kap. 3, 4 a 8","search_en":"Surface of pavements, base courses and bridge decks Measurement of longitudinal and transverse unevenness with a straightedge ČSN 73 6175, kap. 3, 4 a 8","search_zh":"路面、基层及桥面表面 直尺法纵向和横向平整度测量 ČSN 73 6175, kap. 3, 4 a 8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"615a7676476cdcac745e1d5f","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"39","test_object":"Powierzchnia nawierzchni i warstw podbudowy dróg i pomostów","test_object_en":"Surface of pavements, base courses and bridge decks","test_object_zh":"路面、基层及桥面表面","test_object_cs":"Povrch krytů a podkladních vrstev vozovek a mostovek","methodology":"Pomiar nierówności podłużnej i poprzecznej planografem","methodology_en":"Measurement of longitudinal and transverse unevenness with a planograph","methodology_zh":"平整度仪纵向和横向平整度测量","methodology_cs":"Měření podélné a příčné nerovnosti planografem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar nierówności podłużnej i poprzecznej planografem","reference":"ČSN 73 6175, kap. 3, 4 a 9","norm_bases":["ČSN 73 6175, kap. 3, 4 a 9"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powierzchnia nawierzchni i warstw podbudowy dróg i pomostów Pomiar nierówności podłużnej i poprzecznej planografem Povrch krytů a podkladních vrstev vozovek a mostovek Měření podélné a příčné nerovnosti planografem ČSN 73 6175, kap. 3, 4 a 9 Powierzchnia nawierzchni i warstw podbudowy drog i pomostow Pomiar nierownosci podluznej i poprzecznej planografem Povrch krytu a podkladnich vrstev vozovek a mostovek Mereni podelne a pricne nerovnosti planografem CSN 73 6175, kap. 3, 4 a 9","search_en":"Surface of pavements, base courses and bridge decks Measurement of longitudinal and transverse unevenness with a planograph ČSN 73 6175, kap. 3, 4 a 9","search_zh":"路面、基层及桥面表面 平整度仪纵向和横向平整度测量 ČSN 73 6175, kap. 3, 4 a 9","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5253da73c41e812877c98a91","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"40","test_object":"Powierzchnia nawierzchni i poszczególnych warstw dróg i pomostów","test_object_en":"Surface of pavements and individual layers of roads and bridge decks","test_object_zh":"路面及各结构层和桥面表面","test_object_cs":"Povrch krytů a jednotlivých vrstev vozovek a mostovek","methodology":"Pomiar spadku poprzecznego","methodology_en":"Measurement of cross slope","methodology_zh":"横坡测量","methodology_cs":"Měření příčného sklonu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar spadku poprzecznego","reference":"IP 34/11 (ČSN 73 6121:2008, příl. A)","norm_bases":["IP 34/11","ČSN 73 6121:2008"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powierzchnia nawierzchni i poszczególnych warstw dróg i pomostów Pomiar spadku poprzecznego Povrch krytů a jednotlivých vrstev vozovek a mostovek Měření příčného sklonu IP 34/11 (ČSN 73 6121:2008, příl. A) Powierzchnia nawierzchni i poszczegolnych warstw drog i pomostow Pomiar spadku poprzecznego Povrch krytu a jednotlivych vrstev vozovek a mostovek Mereni pricneho sklonu IP 34/11 (CSN 73 6121:2008, pril. A)","search_en":"Surface of pavements and individual layers of roads and bridge decks Measurement of cross slope IP 34/11 (ČSN 73 6121:2008, příl. A)","search_zh":"路面及各结构层和桥面表面 横坡测量 IP 34/11 (ČSN 73 6121:2008, příl. A)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b443e5f86d552c50c815c0a4","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"41","test_object":"Warstwy asfaltowe nawierzchni","test_object_en":"Asphalt pavement layers","test_object_zh":"沥青路面层","test_object_cs":"Asfaltové vrstvy vozovek","methodology":"Oznaczanie wskaźnika zagęszczenia metodami nieniszczącymi","methodology_en":"Determination of degree of compaction by non-destructive methods","methodology_zh":"无损法压实度测定","methodology_cs":"Stanovení míry zhutnění nedestruktivními metodami","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wskaźnika zagęszczenia metodami nieniszczącymi","reference":"ČSN 73 6160, čl. 7.2 b","norm_bases":["ČSN 73 6160, čl. 7.2 b"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwy asfaltowe nawierzchni Oznaczanie wskaźnika zagęszczenia metodami nieniszczącymi Asfaltové vrstvy vozovek Stanovení míry zhutnění nedestruktivními metodami ČSN 73 6160, čl. 7.2 b Warstwy asfaltowe nawierzchni Oznaczanie wskaznika zageszczenia metodami nieniszczacymi Asfaltove vrstvy vozovek Stanoveni miry zhutneni nedestruktivnimi metodami CSN 73 6160, cl. 7.2 b","search_en":"Asphalt pavement layers Determination of degree of compaction by non-destructive methods ČSN 73 6160, čl. 7.2 b","search_zh":"沥青路面层 无损法压实度测定 ČSN 73 6160, čl. 7.2 b","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4b1f10e877ae3574b0d13291","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"42","test_object":"Mieszanka asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Badanie koleinowania","methodology_en":"Wheel tracking test","methodology_zh":"车辙试验","methodology_cs":"Zkouška pojíždění kolem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie koleinowania","reference":"ČSN EN 12697-22+A1","norm_bases":["ČSN EN 12697-22+A1"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa Badanie koleinowania Asfaltová směs Zkouška pojíždění kolem ČSN EN 12697-22+A1 Mieszanka asfaltowa Badanie koleinowania Asfaltova smes Zkouska pojizdeni kolem CSN EN 12697-22+A1","search_en":"Asphalt mixture Wheel tracking test ČSN EN 12697-22+A1","search_zh":"沥青混合料 车辙试验 ČSN EN 12697-22+A1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ba88cd882b532e75e51e8fc3","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"43","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metoda opadu stożka","methodology_en":"Determination of consistence – slump test","methodology_zh":"稠度测定 – 坍落度法","methodology_cs":"Stanovení konzistence – metoda sednutím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metoda opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":"Nový Bydžov","lab_section_en":"Nový Bydžov","lab_section_zh":"新比良佐夫","lab_section_cs":"Nový Bydžov","lab_address":"1. Máje 198, 504 01 Nový Bydžov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Oznaczanie konsystencji – metoda opadu stożka Čerstvý beton Stanovení konzistence – metoda sednutím ČSN EN 12350-2 Mieszanka betonowa (beton swiezy) Oznaczanie konsystencji – metoda opadu stozka Cerstvy beton Stanoveni konzistence – metoda sednutim CSN EN 12350-2","search_en":"Fresh concrete Determination of consistence – slump test ČSN EN 12350-2","search_zh":"新拌混凝土 稠度测定 – 坍落度法 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"11fd73db4f7e050f3534fce0","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"44","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metoda stolika rozpływowego","methodology_en":"Determination of consistence – flow table test","methodology_zh":"稠度测定 – 扩展度法","methodology_cs":"Stanovení konzistence – metoda rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metoda stolika rozpływowego","reference":"ČSN EN 12350-5","norm_bases":["ČSN EN 12350-5"],"lab_section":"Nový Bydžov","lab_section_en":"Nový Bydžov","lab_section_zh":"新比良佐夫","lab_section_cs":"Nový Bydžov","lab_address":"1. Máje 198, 504 01 Nový Bydžov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Oznaczanie konsystencji – metoda stolika rozpływowego Čerstvý beton Stanovení konzistence – metoda rozlitím ČSN EN 12350-5 Mieszanka betonowa (beton swiezy) Oznaczanie konsystencji – metoda stolika rozplywowego Cerstvy beton Stanoveni konzistence – metoda rozlitim CSN EN 12350-5","search_en":"Fresh concrete Determination of consistence – flow table test ČSN EN 12350-5","search_zh":"新拌混凝土 稠度测定 – 扩展度法 ČSN EN 12350-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7de676efee4fff9d9bc90f61","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"45","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie gęstości objętościowej","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":"Nový Bydžov","lab_section_en":"Nový Bydžov","lab_section_zh":"新比良佐夫","lab_section_cs":"Nový Bydžov","lab_address":"1. Máje 198, 504 01 Nový Bydžov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Oznaczanie gęstości objętościowej Čerstvý beton Stanovení objemové hmotnosti ČSN EN 12350-6 Mieszanka betonowa (beton swiezy) Oznaczanie gestosci objetosciowej Cerstvy beton Stanoveni objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Determination of density ČSN EN 12350-6","search_zh":"新拌混凝土 密度测定 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c70c717fc94a742bb3b1ef9f","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"46","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza – metody ciśnieniowe","methodology_en":"Determination of air content – pressure methods","methodology_zh":"含气量测定 – 压力法","methodology_cs":"Stanovení obsahu vzduchu – tlakové metody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza – metody ciśnieniowe","reference":"ČSN EN 12350-7, mimo čl. 4","norm_bases":["ČSN EN 12350-7, mimo čl. 4"],"lab_section":"Nový Bydžov","lab_section_en":"Nový Bydžov","lab_section_zh":"新比良佐夫","lab_section_cs":"Nový Bydžov","lab_address":"1. Máje 198, 504 01 Nový Bydžov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Oznaczanie zawartości powietrza – metody ciśnieniowe Čerstvý beton Stanovení obsahu vzduchu – tlakové metody ČSN EN 12350-7, mimo čl. 4 Mieszanka betonowa (beton swiezy) Oznaczanie zawartosci powietrza – metody cisnieniowe Cerstvy beton Stanoveni obsahu vzduchu – tlakove metody CSN EN 12350-7, mimo cl. 4","search_en":"Fresh concrete Determination of air content – pressure methods ČSN EN 12350-7, mimo čl. 4","search_zh":"新拌混凝土 含气量测定 – 压力法 ČSN EN 12350-7, mimo čl. 4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cafad6677836a8649cbed2db","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"47","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 12390-3","norm_bases":["ČSN EN 12390-3"],"lab_section":"Nový Bydžov","lab_section_en":"Nový Bydžov","lab_section_zh":"新比良佐夫","lab_section_cs":"Nový Bydžov","lab_address":"1. Máje 198, 504 01 Nový Bydžov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie Ztvrdlý beton Stanovení pevnosti v tlaku ČSN EN 12390-3 Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie Ztvrdly beton Stanoveni pevnosti v tlaku CSN EN 12390-3","search_en":"Hardened concrete Determination of compressive strength ČSN EN 12390-3","search_zh":"硬化混凝土 抗压强度测定 ČSN EN 12390-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"15e6ad554d29ded22b9a317b","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"48","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na rozciąganie przy zginaniu","methodology_en":"Determination of flexural tensile strength","methodology_zh":"弯拉强度测定","methodology_cs":"Stanovení pevnosti v tahu ohybem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na rozciąganie przy zginaniu","reference":"ČSN EN 12390-5","norm_bases":["ČSN EN 12390-5"],"lab_section":"Nový Bydžov","lab_section_en":"Nový Bydžov","lab_section_zh":"新比良佐夫","lab_section_cs":"Nový Bydžov","lab_address":"1. Máje 198, 504 01 Nový Bydžov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na rozciąganie przy zginaniu Ztvrdlý beton Stanovení pevnosti v tahu ohybem ČSN EN 12390-5 Beton stwardnialy Oznaczanie wytrzymalosci na rozciaganie przy zginaniu Ztvrdly beton Stanoveni pevnosti v tahu ohybem CSN EN 12390-5","search_en":"Hardened concrete Determination of flexural tensile strength ČSN EN 12390-5","search_zh":"硬化混凝土 弯拉强度测定 ČSN EN 12390-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e25b0a64e024e25abf7ecaf9","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"49","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości objętościowej","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej","reference":"ČSN EN 12390-7","norm_bases":["ČSN EN 12390-7"],"lab_section":"Nový Bydžov","lab_section_en":"Nový Bydžov","lab_section_zh":"新比良佐夫","lab_section_cs":"Nový Bydžov","lab_address":"1. Máje 198, 504 01 Nový Bydžov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości objętościowej Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7 Beton stwardnialy Oznaczanie gestosci objetosciowej Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7","search_en":"Hardened concrete Determination of density ČSN EN 12390-7","search_zh":"硬化混凝土 密度测定 ČSN EN 12390-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9a59b61b14f405f756e01da5","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"50","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie głębokości penetracji wody","methodology_en":"Determination of depth of penetration of water","methodology_zh":"渗水深度测定","methodology_cs":"Stanovení hloubky průsaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości penetracji wody","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":"Nový Bydžov","lab_section_en":"Nový Bydžov","lab_section_zh":"新比良佐夫","lab_section_cs":"Nový Bydžov","lab_address":"1. Máje 198, 504 01 Nový Bydžov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie głębokości penetracji wody Ztvrdlý beton Stanovení hloubky průsaku ČSN EN 12390-8 Beton stwardnialy Oznaczanie glebokosci penetracji wody Ztvrdly beton Stanoveni hloubky prusaku CSN EN 12390-8","search_en":"Hardened concrete Determination of depth of penetration of water ČSN EN 12390-8","search_zh":"硬化混凝土 渗水深度测定 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"87fe505c1bef144d0da514ba","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"51","test_object":"Powierzchnia stwardniałego betonu cementowego","test_object_en":"Surface of hardened cement concrete","test_object_zh":"硬化水泥混凝土表面","test_object_cs":"Povrch cementového ztvrdlého betonu","methodology":"Oznaczanie odporności powierzchni na działanie wody i chemicznych środków odladzających","methodology_en":"Determination of surface resistance to water and chemical de-icing agents","methodology_zh":"表面抗水及化学除冰剂性能测定","methodology_cs":"Stanovení odolnosti povrchu proti působení vody a CHRL","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności powierzchni na działanie wody i chemicznych środków odladzających","reference":"ČSN 73 1326, čl. 13 až 23, 30 až 44","norm_bases":["ČSN 73 1326, čl. 13 až 23, 30 až 44"],"lab_section":"Nový Bydžov","lab_section_en":"Nový Bydžov","lab_section_zh":"新比良佐夫","lab_section_cs":"Nový Bydžov","lab_address":"1. Máje 198, 504 01 Nový Bydžov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powierzchnia stwardniałego betonu cementowego Oznaczanie odporności powierzchni na działanie wody i chemicznych środków odladzających Povrch cementového ztvrdlého betonu Stanovení odolnosti povrchu proti působení vody a CHRL ČSN 73 1326, čl. 13 až 23, 30 až 44 Powierzchnia stwardnialego betonu cementowego Oznaczanie odpornosci powierzchni na dzialanie wody i chemicznych srodkow odladzajacych Povrch cementoveho ztvrdleho betonu Stanoveni odolnosti povrchu proti pusobeni vody a CHRL CSN 73 1326, cl. 13 az 23, 30 az 44","search_en":"Surface of hardened cement concrete Determination of surface resistance to water and chemical de-icing agents ČSN 73 1326, čl. 13 až 23, 30 až 44","search_zh":"硬化水泥混凝土表面 表面抗水及化学除冰剂性能测定 ČSN 73 1326, čl. 13 až 23, 30 až 44","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"daee1a16d7bf70c2dd32ed14","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"52","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wilgotności metodą wagową","methodology_en":"Determination of water content by gravimetry","methodology_zh":"重量法含水率测定","methodology_cs":"Stanovení vlhkosti gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności metodą wagową","reference":"ČSN 73 1316:1989, kap. 2.","norm_bases":["ČSN 73 1316:1989, kap. 2."],"lab_section":"Nový Bydžov","lab_section_en":"Nový Bydžov","lab_section_zh":"新比良佐夫","lab_section_cs":"Nový Bydžov","lab_address":"1. Máje 198, 504 01 Nový Bydžov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wilgotności metodą wagową Ztvrdlý beton Stanovení vlhkosti gravimetricky ČSN 73 1316:1989, kap. 2. Beton stwardnialy Oznaczanie wilgotnosci metoda wagowa Ztvrdly beton Stanoveni vlhkosti gravimetricky CSN 73 1316:1989, kap. 2.","search_en":"Hardened concrete Determination of water content by gravimetry ČSN 73 1316:1989, kap. 2.","search_zh":"硬化混凝土 重量法含水率测定 ČSN 73 1316:1989, kap. 2.","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a0a0f8e555783118f7f127af","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"53","test_object":"Świeży beton samozagęszczalny","test_object_en":"Fresh self-compacting concrete","test_object_zh":"新拌自密实混凝土","test_object_cs":"Čerstvý samozhutnitelný beton","methodology":"Oznaczanie konsystencji – metoda rozpływu stożka","methodology_en":"Determination of consistence – slump-flow test","methodology_zh":"稠度测定 – 坍落扩展度法","methodology_cs":"Stanovení konzistence – metoda sednutí - rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metoda rozpływu stożka","reference":"ČSN EN 12350-8","norm_bases":["ČSN EN 12350-8"],"lab_section":"Nový Bydžov","lab_section_en":"Nový Bydžov","lab_section_zh":"新比良佐夫","lab_section_cs":"Nový Bydžov","lab_address":"1. Máje 198, 504 01 Nový Bydžov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Świeży beton samozagęszczalny Oznaczanie konsystencji – metoda rozpływu stożka Čerstvý samozhutnitelný beton Stanovení konzistence – metoda sednutí - rozlitím ČSN EN 12350-8 Swiezy beton samozageszczalny Oznaczanie konsystencji – metoda rozplywu stozka Cerstvy samozhutnitelny beton Stanoveni konzistence – metoda sednuti - rozlitim CSN EN 12350-8","search_en":"Fresh self-compacting concrete Determination of consistence – slump-flow test ČSN EN 12350-8","search_zh":"新拌自密实混凝土 稠度测定 – 坍落扩展度法 ČSN EN 12350-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f5c320aa9008bb01cb41ea39","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"1","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Pobieranie próbek kruszywa","methodology_en":"Sampling of aggregate","methodology_zh":"集料取样","methodology_cs":"Odběr vzorků kameniva","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek kruszywa","reference":"ČSN EN 932-1","norm_bases":["ČSN EN 932-1"],"lab_section":"Chrudim","lab_section_en":"Chrudim","lab_section_zh":"赫鲁迪姆","lab_section_cs":"Chrudim","lab_address":"Za Pivovarem 611, 537 01 Chrudim","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Pobieranie próbek kruszywa Kamenivo Odběr vzorků kameniva ČSN EN 932-1 Kruszywo Pobieranie probek kruszywa Kamenivo Odber vzorku kameniva CSN EN 932-1","search_en":"Aggregate Sampling of aggregate ČSN EN 932-1","search_zh":"集料 集料取样 ČSN EN 932-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2219f0144abe7825d1fd852b","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"2","test_object":"Mieszanka asfaltowa","test_object_en":"Asphalt mixture","test_object_zh":"沥青混合料","test_object_cs":"Asfaltová směs","methodology":"Pobieranie próbek mieszanki asfaltowej","methodology_en":"Sampling of asphalt mixture","methodology_zh":"沥青混合料取样","methodology_cs":"Odběr vzorků asfaltové směsi","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek mieszanki asfaltowej","reference":"ČSN EN 12697-27, mimo čl. 4.2, 4.5, 4.6, 4.8 a 4.9","norm_bases":["ČSN EN 12697-27, mimo čl. 4.2, 4.5, 4.6, 4.8 a 4.9"],"lab_section":"Hradec Králové","lab_section_en":"Hradec Králové","lab_section_zh":"赫拉德茨-克拉洛韦","lab_section_cs":"Hradec Králové","lab_address":"Resslova 956/13, 500 02 Hradec Králové","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka asfaltowa Pobieranie próbek mieszanki asfaltowej Asfaltová směs Odběr vzorků asfaltové směsi ČSN EN 12697-27, mimo čl. 4.2, 4.5, 4.6, 4.8 a 4.9 Mieszanka asfaltowa Pobieranie probek mieszanki asfaltowej Asfaltova smes Odber vzorku asfaltove smesi CSN EN 12697-27, mimo cl. 4.2, 4.5, 4.6, 4.8 a 4.9","search_en":"Asphalt mixture Sampling of asphalt mixture ČSN EN 12697-27, mimo čl. 4.2, 4.5, 4.6, 4.8 a 4.9","search_zh":"沥青混合料 沥青混合料取样 ČSN EN 12697-27, mimo čl. 4.2, 4.5, 4.6, 4.8 a 4.9","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"edce33a23715e8c60344e9b9","lab_id":"69ad52a4de79e566650fd2e0","country":"CZ","accr_number":"1197","accr_body":"ČIA","row_label":"3","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Pobieranie próbek mieszanki betonowej","methodology_en":"Sampling of fresh concrete","methodology_zh":"新拌混凝土取样","methodology_cs":"Odběr vzorků čerstvého betonu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek mieszanki betonowej","reference":"ČSN EN 12350-1","norm_bases":["ČSN EN 12350-1"],"lab_section":"Nový Bydžov","lab_section_en":"Nový Bydžov","lab_section_zh":"新比良佐夫","lab_section_cs":"Nový Bydžov","lab_address":"1. Máje 198, 504 01 Nový Bydžov","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Pobieranie próbek mieszanki betonowej Čerstvý beton Odběr vzorků čerstvého betonu ČSN EN 12350-1 Mieszanka betonowa (beton swiezy) Pobieranie probek mieszanki betonowej Cerstvy beton Odber vzorku cerstveho betonu CSN EN 12350-1","search_en":"Fresh concrete Sampling of fresh concrete ČSN EN 12350-1","search_zh":"新拌混凝土 新拌混凝土取样 ČSN EN 12350-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}