{"lab":{"_id":"69ad52a4de79e566650fd270","accr_number":"1115","country":"CZ","accr_body":"ČIA","address":"Jiřího Potůčka 115, Trnová, 530 09 Pardubice","categories":["construction"],"city":"Pardubice","imported_at":"2026-03-08T10:42:44.590Z","methods_count":35,"name":"Ústav stavebního zkušebnictví s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1115_150_2024_CS.pdf","1115_150_2024_EN.pdf"],"scope_summary":"Pobieranie próbek i badania mieszanki betonowej, laboratoryjne i terenowe badania materiałów budowlanych, mas, wyrobów, prefabrykatów, konstrukcji budowlanych i ziemnych oraz grubości powłok malarskich.","search_text":"ústav stavebního zkušebnictví s.r.o. jiřího potůčka 115, trnová, 530 09 pardubice 1115","status":"active","updated_at":"2026-03-08T14:52:06.560Z","valid_from":"","valid_until":"02-04-2029","website":"www.uszpce.cz","location":{"type":"Point","coordinates":[15.7812,50.0343]},"email_confidence":"high","email_mx":true,"email_source":"https://www.uszpce.cz","map_coord":[50.05729,15.755723],"map_geo":"nominatim-street","certificate_date":"02.04.2024","certificate_no":"150/2024","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pobieranie próbek i badania mieszanki betonowej, laboratoryjne i terenowe badania materiałów budowlanych, mas, wyrobów, prefabrykatów, konstrukcji budowlanych i ziemnych oraz grubości powłok malarskich.","en":"Sampling and testing of fresh concrete, laboratory and field tests of building materials, compounds, products, precast elements, building and earth structures and of coating thickness.","zh":"新拌混凝土的取样和检测，建筑材料、材料混合物、制品、预制构件、建筑和土方结构以及涂层厚度的实验室和现场试验。","cs":"Odběr a zkoušení čerstvého betonu, laboratorní a polní zkoušky stavebních materiálů, hmot, výrobků, dílců, stavebních a zemních konstrukcí a tloušťky nátěrů."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze","lab_division_cs":"Zkušební laboratoř","lab_division_en":"Testing Laboratory","lab_division_zh":"检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"TN","pl":"Przepis wewnętrzny","en":"Internal regulation","zh":"内部规程","cs":"Interní předpis"},{"abbr":"CHRL","pl":"Chemiczne środki odladzające","en":"Chemical de-icing agents","zh":"化学除冰剂","cs":"Chemické rozmrazovací látky"},{"abbr":"LDD","pl":"Lekka płyta dynamiczna","en":"Light dynamic plate","zh":"轻型动力板","cs":"Lehká dynamická deska"},{"abbr":"NB","pl":"Załącznik krajowy NB","en":"National annex NB","zh":"国家附录NB","cs":"Národní příloha NB"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"07a060380b6428666f8e40754093a8150680250da131c44cdc27454a6c364b3e","source_pdf_url":"https://www.cai.cz/OA/pdf/P150_2024_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"239953ba3d93d4d56f38fdd7","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"1","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Badanie konsystencji metodą opadu stożka","methodology_en":"Slump test","methodology_zh":"坍落度试验","methodology_cs":"Zkouška sednutím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie konsystencji metodą opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa Badanie konsystencji metodą opadu stożka Čerstvý beton Zkouška sednutím ČSN EN 12350-2 Mieszanka betonowa Badanie konsystencji metoda opadu stozka Cerstvy beton Zkouska sednutim CSN EN 12350-2","search_en":"Fresh concrete Slump test ČSN EN 12350-2","search_zh":"新拌混凝土 坍落度试验 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2b1e7d7e69791d4bd1e3f380","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"2","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Badanie konsystencji metodą stolika rozpływowego","methodology_en":"Flow table test","methodology_zh":"流动台试验","methodology_cs":"Zkouška rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie konsystencji metodą stolika rozpływowego","reference":"ČSN EN 12350-5","norm_bases":["ČSN EN 12350-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa Badanie konsystencji metodą stolika rozpływowego Čerstvý beton Zkouška rozlitím ČSN EN 12350-5 Mieszanka betonowa Badanie konsystencji metoda stolika rozplywowego Cerstvy beton Zkouska rozlitim CSN EN 12350-5","search_en":"Fresh concrete Flow table test ČSN EN 12350-5","search_zh":"新拌混凝土 流动台试验 ČSN EN 12350-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e2a096feb3710c9b59a4ba83","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"3","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Badanie gęstości","methodology_en":"Density test","methodology_zh":"密度试验","methodology_cs":"Zkouška objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie gęstości","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa Badanie gęstości Čerstvý beton Zkouška objemové hmotnosti ČSN EN 12350-6 Mieszanka betonowa Badanie gestosci Cerstvy beton Zkouska objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Density test ČSN EN 12350-6","search_zh":"新拌混凝土 密度试验 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f2c9e025d992e5c4bc322934","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"4","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Badanie zawartości powietrza. Metoda ciśnieniowa","methodology_en":"Air content test. Pressure method","methodology_zh":"含气量试验。压力法","methodology_cs":"Zkouška obsahu vzduchu. Tlaková metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie zawartości powietrza. Metoda ciśnieniowa","reference":"ČSN EN 12350-7, mimo kap. 5","norm_bases":["ČSN EN 12350-7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa Badanie zawartości powietrza. Metoda ciśnieniowa Čerstvý beton Zkouška obsahu vzduchu. Tlaková metoda ČSN EN 12350-7, mimo kap. 5 Mieszanka betonowa Badanie zawartosci powietrza. Metoda cisnieniowa Cerstvy beton Zkouska obsahu vzduchu. Tlakova metoda CSN EN 12350-7, mimo kap. 5","search_en":"Fresh concrete Air content test. Pressure method ČSN EN 12350-7, mimo kap. 5","search_zh":"新拌混凝土 含气量试验。压力法 ČSN EN 12350-7, mimo kap. 5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5a02768334b8f931fa33eb58","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"5","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Badanie wytrzymałości na ściskanie","methodology_en":"Compressive strength test","methodology_zh":"抗压强度试验","methodology_cs":"Zkouška pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie wytrzymałości na ściskanie","reference":"ČSN EN 12390-3; ČSN EN 12504-1","norm_bases":["ČSN EN 12390-3","ČSN EN 12504-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Badanie wytrzymałości na ściskanie Ztvrdlý beton Zkouška pevnosti v tlaku ČSN EN 12390-3; ČSN EN 12504-1 Beton stwardnialy Badanie wytrzymalosci na sciskanie Ztvrdly beton Zkouska pevnosti v tlaku CSN EN 12390-3; CSN EN 12504-1","search_en":"Hardened concrete Compressive strength test ČSN EN 12390-3; ČSN EN 12504-1","search_zh":"硬化混凝土 抗压强度试验 ČSN EN 12390-3; ČSN EN 12504-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f2b9725a530ec3d71439b8a4","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"6","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Badanie wytrzymałości na rozciąganie przy zginaniu","methodology_en":"Flexural tensile strength test","methodology_zh":"抗折强度试验","methodology_cs":"Zkouška pevnosti v tahu ohybem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie wytrzymałości na rozciąganie przy zginaniu","reference":"ČSN EN 12390-5","norm_bases":["ČSN EN 12390-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Badanie wytrzymałości na rozciąganie przy zginaniu Ztvrdlý beton Zkouška pevnosti v tahu ohybem ČSN EN 12390-5 Beton stwardnialy Badanie wytrzymalosci na rozciaganie przy zginaniu Ztvrdly beton Zkouska pevnosti v tahu ohybem CSN EN 12390-5","search_en":"Hardened concrete Flexural tensile strength test ČSN EN 12390-5","search_zh":"硬化混凝土 抗折强度试验 ČSN EN 12390-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"491e37b9be1f6059d9c6480a","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"7","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Badanie gęstości","methodology_en":"Density test","methodology_zh":"密度试验","methodology_cs":"Zkouška objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie gęstości","reference":"ČSN EN 12390-7","norm_bases":["ČSN EN 12390-7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Badanie gęstości Ztvrdlý beton Zkouška objemové hmotnosti ČSN EN 12390-7 Beton stwardnialy Badanie gestosci Ztvrdly beton Zkouska objemove hmotnosti CSN EN 12390-7","search_en":"Hardened concrete Density test ČSN EN 12390-7","search_zh":"硬化混凝土 密度试验 ČSN EN 12390-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6093437660b512b454db8d76","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"8","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Badanie głębokości penetracji wody pod ciśnieniem","methodology_en":"Test of depth of penetration of water under pressure","methodology_zh":"压力水渗透深度试验","methodology_cs":"Zkouška hloubky průsaku tlakovou vodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie głębokości penetracji wody pod ciśnieniem","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Badanie głębokości penetracji wody pod ciśnieniem Ztvrdlý beton Zkouška hloubky průsaku tlakovou vodou ČSN EN 12390-8 Beton stwardnialy Badanie glebokosci penetracji wody pod cisnieniem Ztvrdly beton Zkouska hloubky prusaku tlakovou vodou CSN EN 12390-8","search_en":"Hardened concrete Test of depth of penetration of water under pressure ČSN EN 12390-8","search_zh":"硬化混凝土 压力水渗透深度试验 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4f2b51d1db917bd034e3926b","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"9","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Badanie mrozoodporności","methodology_en":"Frost resistance test","methodology_zh":"抗冻性试验","methodology_cs":"Zkouška mrazuvzdornosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie mrozoodporności","reference":"ČSN 73 1322","norm_bases":["ČSN 73 1322"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Badanie mrozoodporności Ztvrdlý beton Zkouška mrazuvzdornosti ČSN 73 1322 Beton stwardnialy Badanie mrozoodpornosci Ztvrdly beton Zkouska mrazuvzdornosti CSN 73 1322","search_en":"Hardened concrete Frost resistance test ČSN 73 1322","search_zh":"硬化混凝土 抗冻性试验 ČSN 73 1322","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b589ba008c9caf641e1aedd6","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"10","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Badanie odporności powierzchni na działanie wody i chemicznych środków odladzających (CHRL)","methodology_en":"Test of surface resistance to water and chemical de-icing agents","methodology_zh":"表面耐水和化学除冰剂作用试验","methodology_cs":"Zkouška odolnosti povrchu proti působení vody a CHRL","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności powierzchni na działanie wody i chemicznych środków odladzających (CHRL)","reference":"ČSN 73 1326, metoda A a C","norm_bases":["ČSN 73 1326"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Badanie odporności powierzchni na działanie wody i chemicznych środków odladzających (CHRL) Ztvrdlý beton Zkouška odolnosti povrchu proti působení vody a CHRL ČSN 73 1326, metoda A a C Beton stwardnialy Badanie odpornosci powierzchni na dzialanie wody i chemicznych srodkow odladzajacych (CHRL) Ztvrdly beton Zkouska odolnosti povrchu proti pusobeni vody a CHRL CSN 73 1326, metoda A a C","search_en":"Hardened concrete Test of surface resistance to water and chemical de-icing agents ČSN 73 1326, metoda A a C","search_zh":"硬化混凝土 表面耐水和化学除冰剂作用试验 ČSN 73 1326, metoda A a C","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e61df683b013374927e1474b","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"11","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Badanie wytrzymałości młotkiem Schmidta (sklerometrem)","methodology_en":"Strength testing with the Schmidt rebound hammer","methodology_zh":"回弹仪（施密特锤）强度检测","methodology_cs":"Zkoušení pevnosti Schmidtovým tvrdoměrem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie wytrzymałości młotkiem Schmidta (sklerometrem)","reference":"ČSN 73 1373, kap. 6.2, 6.3; ČSN EN 12504-2","norm_bases":["ČSN 73 1373","ČSN EN 12504-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Badanie wytrzymałości młotkiem Schmidta (sklerometrem) Ztvrdlý beton Zkoušení pevnosti Schmidtovým tvrdoměrem ČSN 73 1373, kap. 6.2, 6.3; ČSN EN 12504-2 Beton stwardnialy Badanie wytrzymalosci mlotkiem Schmidta (sklerometrem) Ztvrdly beton Zkouseni pevnosti Schmidtovym tvrdomerem CSN 73 1373, kap. 6.2, 6.3; CSN EN 12504-2","search_en":"Hardened concrete Strength testing with the Schmidt rebound hammer ČSN 73 1373, kap. 6.2, 6.3; ČSN EN 12504-2","search_zh":"硬化混凝土 回弹仪（施密特锤）强度检测 ČSN 73 1373, kap. 6.2, 6.3; ČSN EN 12504-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e163c617faf27f69e335e306","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"12","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"骨料","test_object_cs":"Kamenivo","methodology":"Badanie uziarnienia metodą analizy sitowej","methodology_en":"Particle size distribution test by sieving","methodology_zh":"筛分法颗粒级配试验","methodology_cs":"Zkouška zrnitosti sítovým rozborem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie uziarnienia metodą analizy sitowej","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Badanie uziarnienia metodą analizy sitowej Kamenivo Zkouška zrnitosti sítovým rozborem ČSN EN 933-1 Kruszywo Badanie uziarnienia metoda analizy sitowej Kamenivo Zkouska zrnitosti sitovym rozborem CSN EN 933-1","search_en":"Aggregates Particle size distribution test by sieving ČSN EN 933-1","search_zh":"骨料 筛分法颗粒级配试验 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8a0512318cd7f3a6b8493998","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"13","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"骨料","test_object_cs":"Kamenivo","methodology":"Oznaczanie wilgotności","methodology_en":"Determination of moisture content","methodology_zh":"含水率的测定","methodology_cs":"Stanovení vlhkosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności","reference":"ČSN EN 1097-5","norm_bases":["ČSN EN 1097-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie wilgotności Kamenivo Stanovení vlhkosti ČSN EN 1097-5 Kruszywo Oznaczanie wilgotnosci Kamenivo Stanoveni vlhkosti CSN EN 1097-5","search_en":"Aggregates Determination of moisture content ČSN EN 1097-5","search_zh":"骨料 含水率的测定 ČSN EN 1097-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d4b3925299cfb7988e25cc05","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"14","test_object":"Zaprawy","test_object_en":"Mortars","test_object_zh":"砂浆","test_object_cs":"Malty","methodology":"Badanie urabialności","methodology_en":"Workability test","methodology_zh":"工作性试验","methodology_cs":"Zkouška zpracovatelnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie urabialności","reference":"ČSN EN 1015-3","norm_bases":["ČSN EN 1015-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zaprawy Badanie urabialności Malty Zkouška zpracovatelnosti ČSN EN 1015-3 Zaprawy Badanie urabialnosci Malty Zkouska zpracovatelnosti CSN EN 1015-3","search_en":"Mortars Workability test ČSN EN 1015-3","search_zh":"砂浆 工作性试验 ČSN EN 1015-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7c066225e16f33a8c69f13ed","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"15","test_object":"Zaprawy","test_object_en":"Mortars","test_object_zh":"砂浆","test_object_cs":"Malty","methodology":"Badanie wytrzymałości na rozciąganie przy zginaniu i na ściskanie","methodology_en":"Test of flexural and compressive strength","methodology_zh":"抗折强度和抗压强度试验","methodology_cs":"Zkouška pevnosti v tahu za ohybu a v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie wytrzymałości na rozciąganie przy zginaniu i na ściskanie","reference":"ČSN EN 1015-11","norm_bases":["ČSN EN 1015-11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zaprawy Badanie wytrzymałości na rozciąganie przy zginaniu i na ściskanie Malty Zkouška pevnosti v tahu za ohybu a v tlaku ČSN EN 1015-11 Zaprawy Badanie wytrzymalosci na rozciaganie przy zginaniu i na sciskanie Malty Zkouska pevnosti v tahu za ohybu a v tlaku CSN EN 1015-11","search_en":"Mortars Test of flexural and compressive strength ČSN EN 1015-11","search_zh":"砂浆 抗折强度和抗压强度试验 ČSN EN 1015-11","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"944a541d87f68c74a9d53402","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"16","test_object":"Zaprawy","test_object_en":"Mortars","test_object_zh":"砂浆","test_object_cs":"Malty","methodology":"Badanie przyczepności do podłoża","methodology_en":"Test of adhesive strength to the substrate","methodology_zh":"与基层粘结强度试验","methodology_cs":"Zkouška přídržnosti k podkladu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie przyczepności do podłoża","reference":"ČSN EN 1015-12","norm_bases":["ČSN EN 1015-12"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zaprawy Badanie przyczepności do podłoża Malty Zkouška přídržnosti k podkladu ČSN EN 1015-12 Zaprawy Badanie przyczepnosci do podloza Malty Zkouska pridrznosti k podkladu CSN EN 1015-12","search_en":"Mortars Test of adhesive strength to the substrate ČSN EN 1015-12","search_zh":"砂浆 与基层粘结强度试验 ČSN EN 1015-12","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e35c69428b594cef2f6e0c62","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"17","test_object":"Zaprawy","test_object_en":"Mortars","test_object_zh":"砂浆","test_object_cs":"Malty","methodology":"Badanie mrozoodporności","methodology_en":"Frost resistance test","methodology_zh":"抗冻性试验","methodology_cs":"Zkouška mrazuvzdornosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie mrozoodporności","reference":"ČSN 72 2452","norm_bases":["ČSN 72 2452"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zaprawy Badanie mrozoodporności Malty Zkouška mrazuvzdornosti ČSN 72 2452 Zaprawy Badanie mrozoodpornosci Malty Zkouska mrazuvzdornosti CSN 72 2452","search_en":"Mortars Frost resistance test ČSN 72 2452","search_zh":"砂浆 抗冻性试验 ČSN 72 2452","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bd41325cb6504b0ab2d9fcc8","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"18","test_object":"Materiały na jastrychy","test_object_en":"Screed materials","test_object_zh":"找平层材料","test_object_cs":"Potěrové materiály","methodology":"Badanie wytrzymałości na rozciąganie przy zginaniu i na ściskanie","methodology_en":"Test of flexural and compressive strength","methodology_zh":"抗折强度和抗压强度试验","methodology_cs":"Zkouška pevnosti v tahu za ohybu a v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie wytrzymałości na rozciąganie przy zginaniu i na ściskanie","reference":"ČSN EN 13892-2","norm_bases":["ČSN EN 13892-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiały na jastrychy Badanie wytrzymałości na rozciąganie przy zginaniu i na ściskanie Potěrové materiály Zkouška pevnosti v tahu za ohybu a v tlaku ČSN EN 13892-2 Materialy na jastrychy Badanie wytrzymalosci na rozciaganie przy zginaniu i na sciskanie Poterove materialy Zkouska pevnosti v tahu za ohybu a v tlaku CSN EN 13892-2","search_en":"Screed materials Test of flexural and compressive strength ČSN EN 13892-2","search_zh":"找平层材料 抗折强度和抗压强度试验 ČSN EN 13892-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2c703dfa5c9346a7fa716918","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"19","test_object":"Elementy murowe","test_object_en":"Masonry units","test_object_zh":"砌块","test_object_cs":"Zdicí prvky","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度的测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 772-1+A1; ČSN 72 2605, kap. V. A.","norm_bases":["ČSN EN 772-1+A1","ČSN 72 2605"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Elementy murowe Oznaczanie wytrzymałości na ściskanie Zdicí prvky Stanovení pevnosti v tlaku ČSN EN 772-1+A1; ČSN 72 2605, kap. V. A. Elementy murowe Oznaczanie wytrzymalosci na sciskanie Zdici prvky Stanoveni pevnosti v tlaku CSN EN 772-1+A1; CSN 72 2605, kap. V. A.","search_en":"Masonry units Determination of compressive strength ČSN EN 772-1+A1; ČSN 72 2605, kap. V. A.","search_zh":"砌块 抗压强度的测定 ČSN EN 772-1+A1; ČSN 72 2605, kap. V. A.","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7074e6e179f045659a14dd1e","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"20","test_object":"Elementy murowe","test_object_en":"Masonry units","test_object_zh":"砌块","test_object_cs":"Zdicí prvky","methodology":"Oznaczanie nasiąkliwości","methodology_en":"Determination of water absorption","methodology_zh":"吸水率的测定","methodology_cs":"Stanovení nasákavosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie nasiąkliwości","reference":"ČSN EN 772-11","norm_bases":["ČSN EN 772-11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Elementy murowe Oznaczanie nasiąkliwości Zdicí prvky Stanovení nasákavosti ČSN EN 772-11 Elementy murowe Oznaczanie nasiakliwosci Zdici prvky Stanoveni nasakavosti CSN EN 772-11","search_en":"Masonry units Determination of water absorption ČSN EN 772-11","search_zh":"砌块 吸水率的测定 ČSN EN 772-11","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5fb76e8fd9a19744a1baca55","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"21","test_object":"Elementy murowe","test_object_en":"Masonry units","test_object_zh":"砌块","test_object_cs":"Zdicí prvky","methodology":"Oznaczanie gęstości w stanie suchym","methodology_en":"Determination of dry density","methodology_zh":"干密度的测定","methodology_cs":"Stanovení objemové hmotnosti za sucha","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości w stanie suchym","reference":"ČSN EN 772-13; ČSN 72 2603 kap. II/A a C","norm_bases":["ČSN EN 772-13","ČSN 72 2603"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Elementy murowe Oznaczanie gęstości w stanie suchym Zdicí prvky Stanovení objemové hmotnosti za sucha ČSN EN 772-13; ČSN 72 2603 kap. II/A a C Elementy murowe Oznaczanie gestosci w stanie suchym Zdici prvky Stanoveni objemove hmotnosti za sucha CSN EN 772-13; CSN 72 2603 kap. II/A a C","search_en":"Masonry units Determination of dry density ČSN EN 772-13; ČSN 72 2603 kap. II/A a C","search_zh":"砌块 干密度的测定 ČSN EN 772-13; ČSN 72 2603 kap. II/A a C","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"61cb8a05e003946428ca12d6","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"22","test_object":"Elementy murowe","test_object_en":"Masonry units","test_object_zh":"砌块","test_object_cs":"Zdicí prvky","methodology":"Oznaczanie wymiarów","methodology_en":"Determination of dimensions","methodology_zh":"尺寸的测定","methodology_cs":"Stanovení rozměrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wymiarów","reference":"ČSN EN 772-16; ČSN 72 2602","norm_bases":["ČSN EN 772-16","ČSN 72 2602"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Elementy murowe Oznaczanie wymiarów Zdicí prvky Stanovení rozměrů ČSN EN 772-16; ČSN 72 2602 Elementy murowe Oznaczanie wymiarow Zdici prvky Stanoveni rozmeru CSN EN 772-16; CSN 72 2602","search_en":"Masonry units Determination of dimensions ČSN EN 772-16; ČSN 72 2602","search_zh":"砌块 尺寸的测定 ČSN EN 772-16; ČSN 72 2602","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bafa7b145cc939c198dec052","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"23","test_object":"Beton, elementy murowe, materiały budowlane","test_object_en":"Concrete, masonry units, building materials","test_object_zh":"混凝土、砌块、建筑材料","test_object_cs":"Beton, zdící prvky, stavební materiály","methodology":"Oznaczanie wilgotności i nasiąkliwości","methodology_en":"Determination of moisture content and water absorption","methodology_zh":"含水率和吸水率的测定","methodology_cs":"Stanovení vlhkosti a nasákavosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności i nasiąkliwości","reference":"TN-07 (ČSN 73 1316:2003)","norm_bases":["TN-07","ČSN 73 1316:2003"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton, elementy murowe, materiały budowlane Oznaczanie wilgotności i nasiąkliwości Beton, zdící prvky, stavební materiály Stanovení vlhkosti a nasákavosti TN-07 (ČSN 73 1316:2003) Beton, elementy murowe, materialy budowlane Oznaczanie wilgotnosci i nasiakliwosci Beton, zdici prvky, stavebni materialy Stanoveni vlhkosti a nasakavosti TN-07 (CSN 73 1316:2003)","search_en":"Concrete, masonry units, building materials Determination of moisture content and water absorption TN-07 (ČSN 73 1316:2003)","search_zh":"混凝土、砌块、建筑材料 含水率和吸水率的测定 TN-07 (ČSN 73 1316:2003)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"338219f81361973e87267632","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"24","test_object":"Mieszanki niezwiązane i mieszanki związane spoiwami hydraulicznymi","test_object_en":"Unbound and hydraulically bound mixtures","test_object_zh":"无结合料混合料和水硬性结合料稳定混合料","test_object_cs":"Nestmelené směsi a směsi stmelené hydraulickými pojivy","methodology":"Badanie wytrzymałości na ściskanie","methodology_en":"Compressive strength test","methodology_zh":"抗压强度试验","methodology_cs":"Zkouška pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie wytrzymałości na ściskanie","reference":"ČSN EN 13286-41","norm_bases":["ČSN EN 13286-41"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanki niezwiązane i mieszanki związane spoiwami hydraulicznymi Badanie wytrzymałości na ściskanie Nestmelené směsi a směsi stmelené hydraulickými pojivy Zkouška pevnosti v tlaku ČSN EN 13286-41 Mieszanki niezwiazane i mieszanki zwiazane spoiwami hydraulicznymi Badanie wytrzymalosci na sciskanie Nestmelene smesi a smesi stmelene hydraulickymi pojivy Zkouska pevnosti v tlaku CSN EN 13286-41","search_en":"Unbound and hydraulically bound mixtures Compressive strength test ČSN EN 13286-41","search_zh":"无结合料混合料和水硬性结合料稳定混合料 抗压强度试验 ČSN EN 13286-41","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7aed8e6faf4def74b3e3f324","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"25","test_object":"Mieszanki niezwiązane i mieszanki związane spoiwami hydraulicznymi","test_object_en":"Unbound and hydraulically bound mixtures","test_object_zh":"无结合料混合料和水硬性结合料稳定混合料","test_object_cs":"Nestmelené směsi a směsi stmelené hydraulickými pojivy","methodology":"Oznaczanie laboratoryjnej gęstości objętościowej odniesienia i wilgotności – badanie Proctora","methodology_en":"Determination of laboratory reference density and water content – Proctor test","methodology_zh":"实验室参考密度和含水率的测定 – 普氏击实试验","methodology_cs":"Stanovení laboratorní srovnávací objemové hmotnosti a vlhkosti - Proctorova zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie laboratoryjnej gęstości objętościowej odniesienia i wilgotności – badanie Proctora","reference":"ČSN EN 13286-2, články 7.1, 7.2, 7.4, 7.5, příloha NB","norm_bases":["ČSN EN 13286-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanki niezwiązane i mieszanki związane spoiwami hydraulicznymi Oznaczanie laboratoryjnej gęstości objętościowej odniesienia i wilgotności – badanie Proctora Nestmelené směsi a směsi stmelené hydraulickými pojivy Stanovení laboratorní srovnávací objemové hmotnosti a vlhkosti - Proctorova zkouška ČSN EN 13286-2, články 7.1, 7.2, 7.4, 7.5, příloha NB Mieszanki niezwiazane i mieszanki zwiazane spoiwami hydraulicznymi Oznaczanie laboratoryjnej gestosci objetosciowej odniesienia i wilgotnosci – badanie Proctora Nestmelene smesi a smesi stmelene hydraulickymi pojivy Stanoveni laboratorni srovnavaci objemove hmotnosti a vlhkosti - Proctorova zkouska CSN EN 13286-2, clanky 7.1, 7.2, 7.4, 7.5, priloha NB","search_en":"Unbound and hydraulically bound mixtures Determination of laboratory reference density and water content – Proctor test ČSN EN 13286-2, články 7.1, 7.2, 7.4, 7.5, příloha NB","search_zh":"无结合料混合料和水硬性结合料稳定混合料 实验室参考密度和含水率的测定 – 普氏击实试验 ČSN EN 13286-2, články 7.1, 7.2, 7.4, 7.5, příloha NB","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1a98b211605fa1db09f2a15a","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"26","test_object":"Mieszanki związane spoiwami hydraulicznymi","test_object_en":"Hydraulically bound mixtures","test_object_zh":"水硬性结合料稳定混合料","test_object_cs":"Směsi stmelené hydraulickými pojivy","methodology":"Oznaczanie odporności na mróz i wodę","methodology_en":"Determination of resistance to frost and water","methodology_zh":"抗冻和耐水性的测定","methodology_cs":"Stanovení odolnosti proti mrazu a vodě","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności na mróz i wodę","reference":"ČSN 73 6124-1 příloha A","norm_bases":["ČSN 73 6124-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanki związane spoiwami hydraulicznymi Oznaczanie odporności na mróz i wodę Směsi stmelené hydraulickými pojivy Stanovení odolnosti proti mrazu a vodě ČSN 73 6124-1 příloha A Mieszanki zwiazane spoiwami hydraulicznymi Oznaczanie odpornosci na mroz i wode Smesi stmelene hydraulickymi pojivy Stanoveni odolnosti proti mrazu a vode CSN 73 6124-1 priloha A","search_en":"Hydraulically bound mixtures Determination of resistance to frost and water ČSN 73 6124-1 příloha A","search_zh":"水硬性结合料稳定混合料 抗冻和耐水性的测定 ČSN 73 6124-1 příloha A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25d0643e7aace05f00f62265","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"27","test_object":"Grunty, materiały sypkie, warstwy konstrukcyjne","test_object_en":"Soils, bulk materials, structural layers","test_object_zh":"土、散料、结构层","test_object_cs":"Zeminy, sypaniny, konstrukční vrstvy","methodology":"Badanie płytą statyczną (próbne obciążenie statyczne)","methodology_en":"Static plate load test","methodology_zh":"静载试验","methodology_cs":"Statická zatěžovací zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie płytą statyczną (próbne obciążenie statyczne)","reference":"ČSN 72 1006, příloha A, B, D","norm_bases":["ČSN 72 1006"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, materiały sypkie, warstwy konstrukcyjne Badanie płytą statyczną (próbne obciążenie statyczne) Zeminy, sypaniny, konstrukční vrstvy Statická zatěžovací zkouška ČSN 72 1006, příloha A, B, D Grunty, materialy sypkie, warstwy konstrukcyjne Badanie plyta statyczna (probne obciazenie statyczne) Zeminy, sypaniny, konstrukcni vrstvy Staticka zatezovaci zkouska CSN 72 1006, priloha A, B, D","search_en":"Soils, bulk materials, structural layers Static plate load test ČSN 72 1006, příloha A, B, D","search_zh":"土、散料、结构层 静载试验 ČSN 72 1006, příloha A, B, D","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2a1505de9ecb2b3ba47f69a9","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"28","test_object":"Grunty, warstwy konstrukcyjne","test_object_en":"Soils, structural layers","test_object_zh":"土、结构层","test_object_cs":"Zeminy, konstrukční vrstvy","methodology":"Oznaczanie gęstości objętościowej – metoda laboratoryjna","methodology_en":"Determination of bulk density – laboratory method","methodology_zh":"密度的测定 – 实验室法","methodology_cs":"Stanovení objemové hmotnosti - laboratorní metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej – metoda laboratoryjna","reference":"ČSN 72 1010, kap. III","norm_bases":["ČSN 72 1010"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, warstwy konstrukcyjne Oznaczanie gęstości objętościowej – metoda laboratoryjna Zeminy, konstrukční vrstvy Stanovení objemové hmotnosti - laboratorní metoda ČSN 72 1010, kap. III Grunty, warstwy konstrukcyjne Oznaczanie gestosci objetosciowej – metoda laboratoryjna Zeminy, konstrukcni vrstvy Stanoveni objemove hmotnosti - laboratorni metoda CSN 72 1010, kap. III","search_en":"Soils, structural layers Determination of bulk density – laboratory method ČSN 72 1010, kap. III","search_zh":"土、结构层 密度的测定 – 实验室法 ČSN 72 1010, kap. III","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"48421ff49d6def929168a62b","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"29","test_object":"Grunty, warstwy konstrukcyjne","test_object_en":"Soils, structural layers","test_object_zh":"土、结构层","test_object_cs":"Zeminy, konstrukční vrstvy","methodology":"Oznaczanie gęstości objętościowej – metody polowe","methodology_en":"Determination of bulk density – field methods","methodology_zh":"密度的测定 – 现场法","methodology_cs":"Stanovení objemové hmotnosti - polní metody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej – metody polowe","reference":"ČSN 72 1010, kap. IIIA, IIID-1","norm_bases":["ČSN 72 1010"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, warstwy konstrukcyjne Oznaczanie gęstości objętościowej – metody polowe Zeminy, konstrukční vrstvy Stanovení objemové hmotnosti - polní metody ČSN 72 1010, kap. IIIA, IIID-1 Grunty, warstwy konstrukcyjne Oznaczanie gestosci objetosciowej – metody polowe Zeminy, konstrukcni vrstvy Stanoveni objemove hmotnosti - polni metody CSN 72 1010, kap. IIIA, IIID-1","search_en":"Soils, structural layers Determination of bulk density – field methods ČSN 72 1010, kap. IIIA, IIID-1","search_zh":"土、结构层 密度的测定 – 现场法 ČSN 72 1010, kap. IIIA, IIID-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8ffbe3065352e1125bac1ad4","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"30","test_object":"Grunty, warstwy konstrukcyjne","test_object_en":"Soils, structural layers","test_object_zh":"土、结构层","test_object_cs":"Zeminy, konstrukční vrstvy","methodology":"Oznaczanie wilgotności","methodology_en":"Determination of moisture content","methodology_zh":"含水率的测定","methodology_cs":"Stanovení vlhkosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności","reference":"ČSN EN ISO 17892-1","norm_bases":["ČSN EN ISO 17892-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, warstwy konstrukcyjne Oznaczanie wilgotności Zeminy, konstrukční vrstvy Stanovení vlhkosti ČSN EN ISO 17892-1 Grunty, warstwy konstrukcyjne Oznaczanie wilgotnosci Zeminy, konstrukcni vrstvy Stanoveni vlhkosti CSN EN ISO 17892-1","search_en":"Soils, structural layers Determination of moisture content ČSN EN ISO 17892-1","search_zh":"土、结构层 含水率的测定 ČSN EN ISO 17892-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"48f501ec641848080fbd2a21","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"31","test_object":"Grunty, warstwy konstrukcyjne","test_object_en":"Soils, structural layers","test_object_zh":"土、结构层","test_object_cs":"Zeminy, konstrukční vrstvy","methodology":"Badania obciążeniem udarowym lekką płytą dynamiczną (LDD)","methodology_en":"Impact load tests with the light dynamic plate (LDD)","methodology_zh":"轻型动力板（LDD）冲击荷载试验","methodology_cs":"Rázové zatěžovací zkoušky LDD","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badania obciążeniem udarowym lekką płytą dynamiczną (LDD)","reference":"ČSN 73 6192, zařízení skupiny C","norm_bases":["ČSN 73 6192"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, warstwy konstrukcyjne Badania obciążeniem udarowym lekką płytą dynamiczną (LDD) Zeminy, konstrukční vrstvy Rázové zatěžovací zkoušky LDD ČSN 73 6192, zařízení skupiny C Grunty, warstwy konstrukcyjne Badania obciazeniem udarowym lekka plyta dynamiczna (LDD) Zeminy, konstrukcni vrstvy Razove zatezovaci zkousky LDD CSN 73 6192, zarizeni skupiny C","search_en":"Soils, structural layers Impact load tests with the light dynamic plate (LDD) ČSN 73 6192, zařízení skupiny C","search_zh":"土、结构层 轻型动力板（LDD）冲击荷载试验 ČSN 73 6192, zařízení skupiny C","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7b781cd01b73689c25eb1822","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"32","test_object":"Wykończenia powierzchni konstrukcji budowlanych","test_object_en":"Surface finishes of building structures","test_object_zh":"建筑结构表面处理层","test_object_cs":"Povrchové úpravy stavebních konstrukcí","methodology":"Badanie przyczepności do podłoża","methodology_en":"Test of adhesive strength to the substrate","methodology_zh":"与基层粘结强度试验","methodology_cs":"Zkouška přídržnosti k podkladu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie przyczepności do podłoża","reference":"ČSN 73 2577; ČSN 73 6242 příloha B; ČSN EN 13892-8","norm_bases":["ČSN 73 2577","ČSN 73 6242","ČSN EN 13892-8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wykończenia powierzchni konstrukcji budowlanych Badanie przyczepności do podłoża Povrchové úpravy stavebních konstrukcí Zkouška přídržnosti k podkladu ČSN 73 2577; ČSN 73 6242 příloha B; ČSN EN 13892-8 Wykonczenia powierzchni konstrukcji budowlanych Badanie przyczepnosci do podloza Povrchove upravy stavebnich konstrukci Zkouska pridrznosti k podkladu CSN 73 2577; CSN 73 6242 priloha B; CSN EN 13892-8","search_en":"Surface finishes of building structures Test of adhesive strength to the substrate ČSN 73 2577; ČSN 73 6242 příloha B; ČSN EN 13892-8","search_zh":"建筑结构表面处理层 与基层粘结强度试验 ČSN 73 2577; ČSN 73 6242 příloha B; ČSN EN 13892-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7e69ed0831ed7a69fe4b636b","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"33","test_object":"Powłoki malarskie","test_object_en":"Coatings","test_object_zh":"涂层","test_object_cs":"Nátěry","methodology":"Oznaczanie grubości","methodology_en":"Determination of thickness","methodology_zh":"厚度的测定","methodology_cs":"Stanovení tloušťky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie grubości","reference":"ČSN EN ISO 2808, kap. 5.5.7","norm_bases":["ČSN EN ISO 2808"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powłoki malarskie Oznaczanie grubości Nátěry Stanovení tloušťky ČSN EN ISO 2808, kap. 5.5.7 Powloki malarskie Oznaczanie grubosci Natery Stanoveni tloustky CSN EN ISO 2808, kap. 5.5.7","search_en":"Coatings Determination of thickness ČSN EN ISO 2808, kap. 5.5.7","search_zh":"涂层 厚度的测定 ČSN EN ISO 2808, kap. 5.5.7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f96161e759244d5fe878b8d1","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"34","test_object":"Prefabrykaty betonowe","test_object_en":"Precast concrete elements","test_object_zh":"混凝土预制构件","test_object_cs":"Betonové dílce","methodology":"Oznaczanie wymiarów","methodology_en":"Determination of dimensions","methodology_zh":"尺寸的测定","methodology_cs":"Stanovení rozměrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wymiarów","reference":"ČSN 73 0212-5, kap. 4, 5, 6, 7","norm_bases":["ČSN 73 0212-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prefabrykaty betonowe Oznaczanie wymiarów Betonové dílce Stanovení rozměrů ČSN 73 0212-5, kap. 4, 5, 6, 7 Prefabrykaty betonowe Oznaczanie wymiarow Betonove dilce Stanoveni rozmeru CSN 73 0212-5, kap. 4, 5, 6, 7","search_en":"Precast concrete elements Determination of dimensions ČSN 73 0212-5, kap. 4, 5, 6, 7","search_zh":"混凝土预制构件 尺寸的测定 ČSN 73 0212-5, kap. 4, 5, 6, 7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1149995fbc20459a9d5f88e3","lab_id":"69ad52a4de79e566650fd270","country":"CZ","accr_number":"1115","accr_body":"ČIA","row_label":"1","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Pobieranie próbek mieszanki betonowej","methodology_en":"Sampling of fresh concrete","methodology_zh":"新拌混凝土取样","methodology_cs":"Odběr vzorků čerstvého betonu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek mieszanki betonowej","reference":"ČSN EN 12350-1","norm_bases":["ČSN EN 12350-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa Pobieranie próbek mieszanki betonowej Čerstvý beton Odběr vzorků čerstvého betonu ČSN EN 12350-1 Mieszanka betonowa Pobieranie probek mieszanki betonowej Cerstvy beton Odber vzorku cerstveho betonu CSN EN 12350-1","search_en":"Fresh concrete Sampling of fresh concrete ČSN EN 12350-1","search_zh":"新拌混凝土 新拌混凝土取样 ČSN EN 12350-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}