{"lab":{"_id":"69ad52a4de79e566650fd23e","accr_number":"1071","country":"CZ","accr_body":"ČIA","address":"Hroznová 63/2, Pisárky, 603 00 Brno","categories":["food","environment","microbiology"],"city":"Brno","imported_at":"2026-03-08T10:42:44.590Z","methods_count":269,"name":"Ústřední kontrolní a zkušební ústav zemědělský","parse_status":"parsed","parse_version":5,"pdf_files":["1071_175_2025_CS.pdf","1071_175_2025_EN.pdf"],"scope_summary":"Badania pasz i surowców do ich produkcji, gleb, materiału roślinnego, nawozów i surowców do ich produkcji, środków ochrony roślin, oznaczanie parametrów jakościowych materiału siewnego i sadzeniaków, wykrywanie i identyfikacja organizmów szkodliwych dla roślin, w zakresie określonym w załączniku do świadectwa.","search_text":"ústřední kontrolní a zkušební ústav zemědělský hroznová 63/2, pisárky, 603 00 brno 1071","status":"active","updated_at":"2026-03-08T14:52:05.401Z","valid_from":"","valid_until":"10-04-2030","website":"www.ukzuz.cz","location":{"type":"Point","coordinates":[16.6068,49.1951]},"email_confidence":"low","email_mx":true,"email_source":"https://www.ukzuz.cz","needs_review":true,"review_reason":"e-mail ze strony (domena inna niż WWW) — zweryfikuj","map_coord":[49.193837,16.571723],"map_geo":"nominatim-street","certificate_date":"31.07.2026","certificate_no":"369/2026","certificate_replaces":"175/2025 z 10.04.2025","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania pasz i surowców do ich produkcji, gleb, materiału roślinnego, nawozów i surowców do ich produkcji, środków ochrony roślin, oznaczanie parametrów jakościowych materiału siewnego i sadzeniaków, wykrywanie i identyfikacja organizmów szkodliwych dla roślin, w zakresie określonym w załączniku do świadectwa.","en":"Testing of animal feeding stuffs and raw materials for their production, soils, plant material, fertilizers and raw materials for their production, plant protection products, determination of quality parameters of seeds and planting materials, detection and identification of plant pests to the extent as specified in the appendix to this Certificate.","zh":"饲料及其生产原料、土壤、植物材料、肥料及其生产原料、植物保护产品的检测，种子和种苗质量参数测定，植物有害生物检测与鉴定，范围见本证书附件。","cs":"Zkoušení krmiv a surovin pro jejich výrobu, půd, rostlinného materiálu, hnojiv a surovin pro jejich výrobu, přípravků na ochranu rostlin, stanovení kvalitativních parametrů osiva a sadby, detekce a identifikace škodlivých organismů rostlin, vymezené přílohou tohoto osvědčení."}],"flexible_scope":true,"flexible_scope_url":"https://ukzuz.gov.cz/public/portal/ukzuz/laboratore/akreditace","has_en":true,"has_zh":true,"lab_division":"Krajowe Laboratorium Referencyjne","lab_division_cs":"Národní referenční laboratoř","lab_division_en":"National Reference Laboratory","lab_division_zh":"国家参考实验室","lab_locations":[{"code":null,"name":"Ústřední kontrolní a zkušební ústav zemědělský","street":"Hroznová 63/2, Pisárky","postal_code":"603 00","city":"Brno","is_hq":true,"address":"Hroznová 63/2, Pisárky, 603 00 Brno","site":"60300|hroznová63/2pisárky"},{"code":null,"name":"ÚKZÚZ, NRL, Dział NRL OS","street":"Za Opravnou 4","postal_code":"150 06","city":"Praha 5 - Motol","is_hq":false,"address":"Za Opravnou 4, 150 06 Praha 5 - Motol","site":"15006|zaopravnou4"},{"code":null,"name":"ÚKZÚZ, NRL, Dział NRL Praga","street":"Za Opravnou 4","postal_code":"150 06","city":"Praha 5 - Motol","is_hq":false,"address":"Za Opravnou 4, 150 06 Praha 5 - Motol","site":"15006|zaopravnou4"},{"code":null,"name":"ÚKZÚZ, NRL, Wydział NRL Brno","street":"Hroznová 63/2","postal_code":"603 00","city":"Brno","is_hq":false,"address":"Hroznová 63/2, 603 00 Brno","site":"60300|hroznová63/2"},{"code":null,"name":"ÚKZÚZ, NRL, Wydział NRL Opawa","street":"Jaselská 16","postal_code":"746 01","city":"Opava","is_hq":false,"address":"Jaselská 16, 746 01 Opava","site":"74601|jaselská16"},{"code":null,"name":"ÚKZÚZ, NRL, Dział NRL Pilzno","street":"Slovanská alej 20","postal_code":"326 00","city":"Plzeň","is_hq":false,"address":"Slovanská alej 20, 326 00 Plzeň","site":"32600|slovanskáalej20"},{"code":null,"name":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","street":"Lípa 121","postal_code":"582 57","city":"Lípa","is_hq":false,"address":"Lípa 121, 582 57 Lípa","site":"58257|lípa121"},{"code":null,"name":"ÚKZÚZ, NRL, Dział Mikrobiologii i Biochemii","street":"Hroznová 63/2","postal_code":"603 00","city":"Brno","is_hq":false,"address":"Hroznová 63/2, 603 00 Brno","site":"60300|hroznová63/2"},{"code":null,"name":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","street":"Šlechtitelů 773/23","postal_code":"779 00","city":"Olomouc","is_hq":false,"address":"Šlechtitelů 773/23, 779 00 Olomouc","site":"77900|šlechtitelů773/23"},{"code":null,"name":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","street":"Zemědělská 1a","postal_code":"613 00","city":"Brno","is_hq":false,"address":"Zemědělská 1a, 613 00 Brno","site":"61300|zemědělská1a"},{"code":null,"name":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Havlíčkův Brod","street":"Konečná 1930","postal_code":"580 01","city":"Havlíčkův Brod","is_hq":false,"address":"Konečná 1930, 580 01 Havlíčkův Brod","site":"58001|konečná1930"},{"code":null,"name":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Laboratorium Diagnostyki Organizmów Szkodliwych dla Roślin Opawa","street":"Jaselská 552/16","postal_code":"746 01","city":"Opava","is_hq":false,"address":"Jaselská 552/16, 746 01 Opava","site":"74601|jaselská552/16"}],"lab_locations_en":[{"code":null,"name":"Ústřední kontrolní a zkušební ústav zemědělský","street":"Hroznová 63/2, Pisárky","postal_code":"603 00","city":"Brno","is_hq":true,"address":"Hroznová 63/2, Pisárky, 603 00 Brno","site":"60300|hroznová63/2pisárky"},{"code":null,"name":"ÚKZÚZ, NRL, Department of NRL OS","street":"Za Opravnou 4","postal_code":"150 06","city":"Praha 5 - Motol","is_hq":false,"address":"Za Opravnou 4, 150 06 Praha 5 - Motol","site":"15006|zaopravnou4"},{"code":null,"name":"ÚKZÚZ, NRL, Department of NRL Praha","street":"Za Opravnou 4","postal_code":"150 06","city":"Praha 5 - Motol","is_hq":false,"address":"Za Opravnou 4, 150 06 Praha 5 - Motol","site":"15006|zaopravnou4"},{"code":null,"name":"ÚKZÚZ, NRL, Division of NRL Brno","street":"Hroznová 63/2","postal_code":"603 00","city":"Brno","is_hq":false,"address":"Hroznová 63/2, 603 00 Brno","site":"60300|hroznová63/2"},{"code":null,"name":"ÚKZÚZ, NRL, Division of NRL Opava","street":"Jaselská 16","postal_code":"746 01","city":"Opava","is_hq":false,"address":"Jaselská 16, 746 01 Opava","site":"74601|jaselská16"},{"code":null,"name":"ÚKZÚZ, NRL, Department of NRL Plzeň","street":"Slovanská alej 20","postal_code":"326 00","city":"Plzeň","is_hq":false,"address":"Slovanská alej 20, 326 00 Plzeň","site":"32600|slovanskáalej20"},{"code":null,"name":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","street":"Lípa 121","postal_code":"582 57","city":"Lípa","is_hq":false,"address":"Lípa 121, 582 57 Lípa","site":"58257|lípa121"},{"code":null,"name":"ÚKZÚZ, NRL, Department of Microbiology and Biochemistry","street":"Hroznová 63/2","postal_code":"603 00","city":"Brno","is_hq":false,"address":"Hroznová 63/2, 603 00 Brno","site":"60300|hroznová63/2"},{"code":null,"name":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","street":"Šlechtitelů 773/23","postal_code":"779 00","city":"Olomouc","is_hq":false,"address":"Šlechtitelů 773/23, 779 00 Olomouc","site":"77900|šlechtitelů773/23"},{"code":null,"name":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","street":"Zemědělská 1a","postal_code":"613 00","city":"Brno","is_hq":false,"address":"Zemědělská 1a, 613 00 Brno","site":"61300|zemědělská1a"},{"code":null,"name":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Havlíčkův Brod","street":"Konečná 1930","postal_code":"580 01","city":"Havlíčkův Brod","is_hq":false,"address":"Konečná 1930, 580 01 Havlíčkův Brod","site":"58001|konečná1930"},{"code":null,"name":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Laboratory of Plant Pest Diagnostics Opava","street":"Jaselská 552/16","postal_code":"746 01","city":"Opava","is_hq":false,"address":"Jaselská 552/16, 746 01 Opava","site":"74601|jaselská552/16"}],"lab_locations_zh":[{"code":null,"name":"Ústřední kontrolní a zkušební ústav zemědělský","street":"Hroznová 63/2, Pisárky","postal_code":"603 00","city":"Brno","is_hq":true,"address":"Hroznová 63/2, Pisárky, 603 00 Brno","site":"60300|hroznová63/2pisárky"},{"code":null,"name":"ÚKZÚZ, NRL，NRL OS科","street":"Za Opravnou 4","postal_code":"150 06","city":"Praha 5 - Motol","is_hq":false,"address":"Za Opravnou 4, 150 06 Praha 5 - Motol","site":"15006|zaopravnou4"},{"code":null,"name":"ÚKZÚZ, NRL，NRL布拉格科","street":"Za Opravnou 4","postal_code":"150 06","city":"Praha 5 - Motol","is_hq":false,"address":"Za Opravnou 4, 150 06 Praha 5 - Motol","site":"15006|zaopravnou4"},{"code":null,"name":"ÚKZÚZ, NRL，NRL布尔诺处","street":"Hroznová 63/2","postal_code":"603 00","city":"Brno","is_hq":false,"address":"Hroznová 63/2, 603 00 Brno","site":"60300|hroznová63/2"},{"code":null,"name":"ÚKZÚZ, NRL，NRL奥帕瓦处","street":"Jaselská 16","postal_code":"746 01","city":"Opava","is_hq":false,"address":"Jaselská 16, 746 01 Opava","site":"74601|jaselská16"},{"code":null,"name":"ÚKZÚZ, NRL，NRL比尔森科","street":"Slovanská alej 20","postal_code":"326 00","city":"Plzeň","is_hq":false,"address":"Slovanská alej 20, 326 00 Plzeň","site":"32600|slovanskáalej20"},{"code":null,"name":"ÚKZÚZ, NRL，植物和饲料专项分析科","street":"Lípa 121","postal_code":"582 57","city":"Lípa","is_hq":false,"address":"Lípa 121, 582 57 Lípa","site":"58257|lípa121"},{"code":null,"name":"ÚKZÚZ, NRL，微生物与生物化学科","street":"Hroznová 63/2","postal_code":"603 00","city":"Brno","is_hq":false,"address":"Hroznová 63/2, 603 00 Brno","site":"60300|hroznová63/2"},{"code":null,"name":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","street":"Šlechtitelů 773/23","postal_code":"779 00","city":"Olomouc","is_hq":false,"address":"Šlechtitelů 773/23, 779 00 Olomouc","site":"77900|šlechtitelů773/23"},{"code":null,"name":"ÚKZÚZ, NRL，植物保护产品检测科","street":"Zemědělská 1a","postal_code":"613 00","city":"Brno","is_hq":false,"address":"Zemědělská 1a, 613 00 Brno","site":"61300|zemědělská1a"},{"code":null,"name":"ÚKZÚZ, NRL，植物有害生物诊断处，哈夫利奇库夫布罗德植物有害生物诊断科","street":"Konečná 1930","postal_code":"580 01","city":"Havlíčkův Brod","is_hq":false,"address":"Konečná 1930, 580 01 Havlíčkův Brod","site":"58001|konečná1930"},{"code":null,"name":"ÚKZÚZ, NRL，植物有害生物诊断处，奥帕瓦植物有害生物诊断实验室","street":"Jaselská 552/16","postal_code":"746 01","city":"Opava","is_hq":false,"address":"Jaselská 552/16, 746 01 Opava","site":"74601|jaselská552/16"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"CIPAC MT","pl":"Międzynarodowa organizacja współpracy w zakresie analiz pestycydów (Collaborative International Pesticides Analytical Council Miscellaneous Techniques)","en":"Collaborative International Pesticides Analytical Council Miscellaneous Techniques","zh":"国际农药分析协作委员会（CIPAC）杂项技术","cs":"Mezinárodní organizace pro spolupráci v oblasti analýz pesticidů (Collaborative International Pesticides Analytical Council Miscellaneous Techniques)"},{"abbr":"DAS-ELISA","pl":"Double Antibody Sandwich Enzyme-Linked Immunosorbent Assay, podwójny kanapkowy test immunoenzymatyczny","en":"Double Antibody Sandwich Enzyme Linked Immunosorbent Assay","zh":"双抗体夹心酶联免疫吸附测定","cs":"Double Antibody Sandwich Enzyme-Linked Immunosorbent Assay, dvojitá sendvičová enzymová imunoanalýza"},{"abbr":"EC","pl":"Koncentraty do sporządzania emulsji","en":"Emulsifiable concentrates","zh":"乳油","cs":"Emulgovatelné koncentráty"},{"abbr":"ELISA","pl":"Test immunoenzymatyczny (Enzyme linked immuno sorbent assay)","en":"Enzyme Linked Immuno Sorbent Assay","zh":"酶联免疫吸附测定","cs":"Enzyme linked immuno sorbent assay"},{"abbr":"ETA-AAS","pl":"Absorpcyjna spektrometria atomowa z atomizacją elektrotermiczną","en":"Electrothermal Atomization-Atomic Absorption Spectrometry","zh":"电热原子化原子吸收光谱法","cs":"Atomová absorpční spektrometrie s elektrotermickou atomizací"},{"abbr":"EW","pl":"Emulsja typu olej w wodzie","en":"Emulsion of type oil in water","zh":"水包油型乳液","cs":"Emulze typu olej ve vodě"},{"abbr":"FAAS","pl":"Płomieniowa absorpcyjna spektrometria atomowa","en":"Flame Atomic Absorption Spectrometry","zh":"火焰原子吸收光谱法","cs":"Atomová absorpční spektrometrie s atomizací v plamenu"},{"abbr":"FAES","pl":"Płomieniowa emisyjna spektrometria atomowa","en":"Flame Atomic Emission Spectrometry","zh":"火焰原子发射光谱法","cs":"Atomová emisní spektrometrie s atomizací v plamenu"},{"abbr":"FCH","pl":"Fizykochemiczny","en":"Physico-chemical","zh":"理化","cs":"Fyzikálně-chemický"},{"abbr":"FID","pl":"Detektor płomieniowo-jonizacyjny","en":"Flame Ionisation Detector","zh":"火焰离子化检测器","cs":"Plamenově ionizační detektor"},{"abbr":"FLD","pl":"Detektor fluorescencyjny","en":"Fluorescence Detector","zh":"荧光检测器","cs":"Fluorescenční detektor"},{"abbr":"GC","pl":"Chromatografia gazowa","en":"Gas Chromatography","zh":"气相色谱法","cs":"Plynová chromatografie"},{"abbr":"GC/FID","pl":"Chromatografia gazowa z detektorem FID","en":"Gas Chromatography with FID detector","zh":"气相色谱-火焰离子化检测法","cs":"Plynová chromatografie s FID detektorem"},{"abbr":"GC/MS","pl":"Chromatografia gazowa z detekcją mas","en":"Gas Chromatography with Mass Spectrometric Detection","zh":"气相色谱-质谱法","cs":"Plynová chromatografie s hmotnostní detekcí"},{"abbr":"GC-MS/MS","pl":"Chromatografia gazowa z tandemową spektrometrią mas","en":"Gas Chromatography with Tandem Mass Spectrometric Detection","zh":"气相色谱-串联质谱法","cs":"Plynová chromatografie s tandemovou hmotnostní spektrometrií"},{"abbr":"GMO","pl":"Organizm genetycznie zmodyfikowany","en":"Genetically Modified Organism","zh":"转基因生物","cs":"Geneticky modifikovaný organismus"},{"abbr":"HG-AAS","pl":"Absorpcyjna spektrometria atomowa z generowaniem wodorków","en":"Hydride Generation-Atomic Absorption Spectrometry","zh":"氢化物发生原子吸收光谱法","cs":"Atomová absorpční spektrometrie s metodou generování hydridů"},{"abbr":"HPLC","pl":"Wysokosprawna chromatografia cieczowa","en":"High Performance Liquid Chromatography","zh":"高效液相色谱法","cs":"Vysokoúčinná kapalinová chromatografie"},{"abbr":"HPLC/FLD","pl":"Wysokosprawna chromatografia cieczowa z detektorem fluorescencyjnym","en":"High Performance Liquid Chromatography with Fluorescence Detector","zh":"高效液相色谱-荧光检测法","cs":"Vysokoúčinná kapalinová chromatografie s fluorescenčním detektorem"},{"abbr":"HPLC/UV","pl":"Wysokosprawna chromatografia cieczowa z detektorem UV","en":"High Performance Liquid Chromatography with UV Detector","zh":"高效液相色谱-紫外检测法","cs":"Vysokoúčinná kapalinová chromatografie s UV detektorem"},{"abbr":"HPLC/DAD","pl":"Wysokosprawna chromatografia cieczowa z detektorem diodowym (DAD)","en":"High Performance Liquid Chromatography with Diode Array Detector","zh":"高效液相色谱-二极管阵列检测法","cs":"Vysokoúčinná kapalinová chromatografie s diode array detektorem"},{"abbr":"HS-GC/FID","pl":"Chromatografia gazowa z detektorem FID i dozowaniem fazy gazowej próbki (headspace)","en":"Gas Chromatography with FID Detector and gas-phase sample injection (headspace)","zh":"顶空进样气相色谱-火焰离子化检测法","cs":"Plynová chromatografie s FID detektorem a nástřikem plynné fáze vzorků (headspace)"},{"abbr":"CH","pl":"Chemiczny","en":"Chemical","zh":"化学","cs":"Chemický"},{"abbr":"ICP-MS","pl":"Spektrometria mas z plazmą indukcyjnie sprzężoną","en":"Inductively Coupled Plasma-Mass Spectroscopy","zh":"电感耦合等离子体质谱法","cs":"Hmotnostní spektrometrie s indukčně vázaným plazmatem"},{"abbr":"ICP-OES","pl":"Optyczna spektrometria emisyjna z plazmą indukcyjnie sprzężoną","en":"Inductively Coupled Plasma-Optical Emission Spectroscopy","zh":"电感耦合等离子体发射光谱法","cs":"Optická emisní spektrometrie s indukčně vázaným plazmatem"},{"abbr":"ISE","pl":"Elektroda jonoselektywna","en":"Ion Selective Electrode","zh":"离子选择电极","cs":"Iontově-selektivní elektroda"},{"abbr":"ISTA","pl":"International Seed Testing Association, Międzynarodowe Stowarzyszenie Oceny Nasion","en":"International Seed Testing Association","zh":"国际种子检验协会","cs":"International Seed Testing Association, Mezinárodní asociace pro testování osiva"},{"abbr":"JPP ÚKZÚZ","pl":"Jednolite procedury robocze ÚKZÚZ","en":"Uniform Working Procedures ÚKZÚZ","zh":"ÚKZÚZ统一工作程序","cs":"Jednotné pracovní postupy ÚKZÚZ"},{"abbr":"LC","pl":"Chromatografia cieczowa","en":"Liquid Chromatography","zh":"液相色谱法","cs":"Kapalinová chromatografie"},{"abbr":"LC-MS","pl":"Chromatografia cieczowa z detekcją mas","en":"Liquid Chromatography with Mass Spectrometric Detection","zh":"液相色谱-质谱法","cs":"Kapalinová chromatografie s hmotnostní detekcí"},{"abbr":"LC-MS/MS","pl":"Chromatografia cieczowa z tandemową spektrometrią mas","en":"Liquid Chromatography with Tandem Mass Spectrometry","zh":"液相色谱-串联质谱法","cs":"Kapalinová chromatografie s tandemovou hmotnostní spektrometrií"},{"abbr":"LC/UV","pl":"Chromatografia cieczowa z detektorem UV","en":"Liquid Chromatography with UV Detector","zh":"液相色谱-紫外检测法","cs":"Kapalinová chromatografie s UV detektorem"},{"abbr":"MALDI-TOF","pl":"Spektrometria mas z desorpcją laserową wspomaganą matrycą","en":"Matrix-Assisted Laser Desorption/Ionisation Time-of-Flight Mass Spectrometry","zh":"基质辅助激光解吸电离飞行时间质谱法","cs":"Hmotnostní spektrometrie s laserovou desorpcí a ionizací za účasti matrice"},{"abbr":"MS","pl":"Spektrometria mas","en":"Mass Spectrometry","zh":"质谱法","cs":"Hmotnostní spektrometrie"},{"abbr":"NIRS","pl":"Spektroskopia bliskiej podczerwieni","en":"Near Infrared Spectroscopy","zh":"近红外光谱法","cs":"Blízká infračervená spektroskopie"},{"abbr":"PCR","pl":"Łańcuchowa reakcja polimerazy","en":"Polymerase Chain Reaction","zh":"聚合酶链式反应","cs":"Polymerázová řetězová reakce"},{"abbr":"POR","pl":"Środki ochrony roślin","en":"Plant Protection Products","zh":"植物保护产品","cs":"Přípravky na ochranu rostlin"},{"abbr":"qPCR","pl":"Ilościowa łańcuchowa reakcja polimerazy","en":"Quantitative Polymerase Chain Reaction","zh":"定量聚合酶链式反应","cs":"Kvantitativní polymerázová řetězová reakce"},{"abbr":"SOP","pl":"Standardowa procedura operacyjna","en":"Standard Operating Procedure","zh":"标准操作程序","cs":"Standardní operační postup"},{"abbr":"UPOV","pl":"The International Union for the Protection of New Varieties of Plants, Międzynarodowy Związek Ochrony Nowych Odmian Roślin","en":"The International Union for the Protection of New Varieties of Plants","zh":"国际植物新品种保护联盟","cs":"The International Union for the Protection of New Varieties of Plants, Mezinárodní unie pro ochranu nových odrůd rostlin"},{"abbr":"UV","pl":"Nadfiolet","en":"Ultraviolet","zh":"紫外区","cs":"Ultrafialová oblast"}],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników badań.","en":"The laboratory provides opinions and interpretations of the test results.","zh":"实验室提供检测结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků zkoušek."}],"source_lang":"cs","source_pdf_sha256":"688b0c0600cde22fa82d29cd7d410ba9402fc6b936511e4f6f59d8111dc3ef83","source_pdf_url":"https://www.cai.cz/OA/pdf/369_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/369_2026_EN.pdf"},"methods":[{"_id":"2bdc23a2450ae0c8c6c34515","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"1","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osivo","methodology":"Oznaczanie wilgotności metodą wagową","methodology_en":"Determination of moisture content by gravimetric method","methodology_zh":"重量法测定水分","methodology_cs":"Stanovení vlhkosti gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności metodą wagową","reference":"SOP 003, kap. 4.2 (Metodika zkoušení osiva a sadby, kap. 9, metody podle 9.3.5.1 a 9.3.5.2; ISTA, kap. 9.1.2, 9.1.3)","norm_bases":["SOP 003","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny Oznaczanie wilgotności metodą wagową Osivo Stanovení vlhkosti gravimetricky SOP 003, kap. 4.2 (Metodika zkoušení osiva a sadby, kap. 9, metody podle 9.3.5.1 a 9.3.5.2; ISTA, kap. 9.1.2, 9.1.3) Material siewny Oznaczanie wilgotnosci metoda wagowa Osivo Stanoveni vlhkosti gravimetricky SOP 003, kap. 4.2 (Metodika zkouseni osiva a sadby, kap. 9, metody podle 9.3.5.1 a 9.3.5.2; ISTA, kap. 9.1.2, 9.1.3)","search_en":"Seed Determination of moisture content by gravimetric method SOP 003, kap. 4.2 (Metodika zkoušení osiva a sadby, kap. 9, metody podle 9.3.5.1 a 9.3.5.2; ISTA, kap. 9.1.2, 9.1.3)","search_zh":"种子 重量法测定水分 SOP 003, kap. 4.2 (Metodika zkoušení osiva a sadby, kap. 9, metody podle 9.3.5.1 a 9.3.5.2; ISTA, kap. 9.1.2, 9.1.3)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4bf6869a3f20cd8e8f76fca","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"2","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osivo","methodology":"Wykrywanie szkodników zwierzęcych metodą makroskopową i mikroskopową","methodology_en":"Detection of animal pests by macroscopic and microscopic method","methodology_zh":"宏观和显微镜法检测动物性害虫","methodology_cs":"Zjišťování živočišných škůdců makroskopicky a mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie szkodników zwierzęcych metodą makroskopową i mikroskopową","reference":"SOP 004 (Metodika zkoušení osiva a sadby, kap. 12; ISTA, kap. 7)","norm_bases":["SOP 004","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny Wykrywanie szkodników zwierzęcych metodą makroskopową i mikroskopową Osivo Zjišťování živočišných škůdců makroskopicky a mikroskopicky SOP 004 (Metodika zkoušení osiva a sadby, kap. 12; ISTA, kap. 7) Material siewny Wykrywanie szkodnikow zwierzecych metoda makroskopowa i mikroskopowa Osivo Zjistovani zivocisnych skudcu makroskopicky a mikroskopicky SOP 004 (Metodika zkouseni osiva a sadby, kap. 12; ISTA, kap. 7)","search_en":"Seed Detection of animal pests by macroscopic and microscopic method SOP 004 (Metodika zkoušení osiva a sadby, kap. 12; ISTA, kap. 7)","search_zh":"种子 宏观和显微镜法检测动物性害虫 SOP 004 (Metodika zkoušení osiva a sadby, kap. 12; ISTA, kap. 7)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"210a74c52574efd678adeb42","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"3","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osivo","methodology":"Oznaczanie frakcji wielkościowych – sortowanie sitowe","methodology_en":"Determining size fractions – sieve sorting","methodology_zh":"粒度分级测定——筛分","methodology_cs":"Stanovení velikostních podílů ̶ sítové třídění","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie frakcji wielkościowych – sortowanie sitowe","reference":"SOP 006 (Metodika zkoušení osiva a sadby, kap. 13)","norm_bases":["SOP 006","Metodika zkoušení osiva a sadby"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny Oznaczanie frakcji wielkościowych – sortowanie sitowe Osivo Stanovení velikostních podílů ̶ sítové třídění SOP 006 (Metodika zkoušení osiva a sadby, kap. 13) Material siewny Oznaczanie frakcji wielkosciowych – sortowanie sitowe Osivo Stanoveni velikostnich podilu  sitove trideni SOP 006 (Metodika zkouseni osiva a sadby, kap. 13)","search_en":"Seed Determining size fractions – sieve sorting SOP 006 (Metodika zkoušení osiva a sadby, kap. 13)","search_zh":"种子 粒度分级测定——筛分 SOP 006 (Metodika zkoušení osiva a sadby, kap. 13)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"74fa247ff04a772452606956","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"4","test_object":"Materiał siewny otoczkowany","test_object_en":"Coated seed","test_object_zh":"包衣种子","test_object_cs":"Obalované osivo","methodology":"Oznaczanie frakcji wielkościowych – sortowanie sitowe","methodology_en":"Determining size fractions – sieve sorting","methodology_zh":"粒度分级测定——筛分","methodology_cs":"Stanovení velikostních podílů ̶ sítové třídění","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie frakcji wielkościowych – sortowanie sitowe","reference":"SOP 016, kap. 3.5 (Metodika zkoušení osiva a sadby, kap. 11.8)","norm_bases":["SOP 016","Metodika zkoušení osiva a sadby"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny otoczkowany Oznaczanie frakcji wielkościowych – sortowanie sitowe Obalované osivo Stanovení velikostních podílů ̶ sítové třídění SOP 016, kap. 3.5 (Metodika zkoušení osiva a sadby, kap. 11.8) Material siewny otoczkowany Oznaczanie frakcji wielkosciowych – sortowanie sitowe Obalovane osivo Stanoveni velikostnich podilu  sitove trideni SOP 016, kap. 3.5 (Metodika zkouseni osiva a sadby, kap. 11.8)","search_en":"Coated seed Determining size fractions – sieve sorting SOP 016, kap. 3.5 (Metodika zkoušení osiva a sadby, kap. 11.8)","search_zh":"包衣种子 粒度分级测定——筛分 SOP 016, kap. 3.5 (Metodika zkoušení osiva a sadby, kap. 11.8)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8cd3121597a8dddf1f3201c0","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"5","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osivo","methodology":"Oznaczanie czystości metodą makroskopową","methodology_en":"Determination of purity by macroscopic method","methodology_zh":"宏观法测定净度","methodology_cs":"Stanovení čistoty makroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie czystości metodą makroskopową","reference":"SOP 007 (Metodika zkoušení osiva a sadby, kap. 3; ISTA, kap. 3)","norm_bases":["SOP 007","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny Oznaczanie czystości metodą makroskopową Osivo Stanovení čistoty makroskopicky SOP 007 (Metodika zkoušení osiva a sadby, kap. 3; ISTA, kap. 3) Material siewny Oznaczanie czystosci metoda makroskopowa Osivo Stanoveni cistoty makroskopicky SOP 007 (Metodika zkouseni osiva a sadby, kap. 3; ISTA, kap. 3)","search_en":"Seed Determination of purity by macroscopic method SOP 007 (Metodika zkoušení osiva a sadby, kap. 3; ISTA, kap. 3)","search_zh":"种子 宏观法测定净度 SOP 007 (Metodika zkoušení osiva a sadby, kap. 3; ISTA, kap. 3)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2335c9407859cce73dc48026","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"6","test_object":"Materiał siewny otoczkowany","test_object_en":"Coated seed","test_object_zh":"包衣种子","test_object_cs":"Obalované osivo","methodology":"Oznaczanie czystości metodą makroskopową","methodology_en":"Determination of purity by macroscopic method","methodology_zh":"宏观法测定净度","methodology_cs":"Stanovení čistoty makroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie czystości metodą makroskopową","reference":"SOP 016, kap. 4.2 (Metodika zkoušení osiva a sadby, kap. 11.4; ISTA, kap. 11.3)","norm_bases":["SOP 016","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny otoczkowany Oznaczanie czystości metodą makroskopową Obalované osivo Stanovení čistoty makroskopicky SOP 016, kap. 4.2 (Metodika zkoušení osiva a sadby, kap. 11.4; ISTA, kap. 11.3) Material siewny otoczkowany Oznaczanie czystosci metoda makroskopowa Obalovane osivo Stanoveni cistoty makroskopicky SOP 016, kap. 4.2 (Metodika zkouseni osiva a sadby, kap. 11.4; ISTA, kap. 11.3)","search_en":"Coated seed Determination of purity by macroscopic method SOP 016, kap. 4.2 (Metodika zkoušení osiva a sadby, kap. 11.4; ISTA, kap. 11.3)","search_zh":"包衣种子 宏观法测定净度 SOP 016, kap. 4.2 (Metodika zkoušení osiva a sadby, kap. 11.4; ISTA, kap. 11.3)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0a2dbaa378e84f4527d3637a","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"7","test_object":"Mieszanki materiału siewnego","test_object_en":"Seed mixtures","test_object_zh":"混合种子","test_object_cs":"Směsi osiv","methodology":"Oznaczanie czystości metodą makroskopową","methodology_en":"Determination of purity by macroscopic method","methodology_zh":"宏观法测定净度","methodology_cs":"Stanovení čistoty makroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie czystości metodą makroskopową","reference":"SOP 022, kap. 4.4 (Metodika zkoušení osiva a sadby, kap. 17.4; ISTA, kap. 18.4)","norm_bases":["SOP 022","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanki materiału siewnego Oznaczanie czystości metodą makroskopową Směsi osiv Stanovení čistoty makroskopicky SOP 022, kap. 4.4 (Metodika zkoušení osiva a sadby, kap. 17.4; ISTA, kap. 18.4) Mieszanki materialu siewnego Oznaczanie czystosci metoda makroskopowa Smesi osiv Stanoveni cistoty makroskopicky SOP 022, kap. 4.4 (Metodika zkouseni osiva a sadby, kap. 17.4; ISTA, kap. 18.4)","search_en":"Seed mixtures Determination of purity by macroscopic method SOP 022, kap. 4.4 (Metodika zkoušení osiva a sadby, kap. 17.4; ISTA, kap. 18.4)","search_zh":"混合种子 宏观法测定净度 SOP 022, kap. 4.4 (Metodika zkoušení osiva a sadby, kap. 17.4; ISTA, kap. 18.4)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cad6c02288200179af1650b5","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"8","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osivo","methodology":"Oznaczanie masy tysiąca nasion metodą wagową","methodology_en":"Determination of thousand seeds weight by gravimetric method","methodology_zh":"重量法测定千粒重","methodology_cs":"Stanovení hmotnosti tisíce semen gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie masy tysiąca nasion metodą wagową","reference":"SOP 008 (Metodika zkoušení osiva a sadby, kap. 10; ISTA, kap. 10)","norm_bases":["SOP 008","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny Oznaczanie masy tysiąca nasion metodą wagową Osivo Stanovení hmotnosti tisíce semen gravimetricky SOP 008 (Metodika zkoušení osiva a sadby, kap. 10; ISTA, kap. 10) Material siewny Oznaczanie masy tysiaca nasion metoda wagowa Osivo Stanoveni hmotnosti tisice semen gravimetricky SOP 008 (Metodika zkouseni osiva a sadby, kap. 10; ISTA, kap. 10)","search_en":"Seed Determination of thousand seeds weight by gravimetric method SOP 008 (Metodika zkoušení osiva a sadby, kap. 10; ISTA, kap. 10)","search_zh":"种子 重量法测定千粒重 SOP 008 (Metodika zkoušení osiva a sadby, kap. 10; ISTA, kap. 10)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"73bbdb21dce20e38780af11f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"9","test_object":"Mieszanki materiału siewnego","test_object_en":"Seed mixtures","test_object_zh":"混合种子","test_object_cs":"Směsi osiv","methodology":"Oznaczanie masy tysiąca nasion metodą wagową","methodology_en":"Determination of thousand seeds weight by gravimetric method","methodology_zh":"重量法测定千粒重","methodology_cs":"Stanovení hmotnosti tisíce semen gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie masy tysiąca nasion metodą wagową","reference":"SOP 022, kap. 4.7 (Metodika zkoušení osiva a sadby, kap. 17.7; ISTA, kap. 18.7)","norm_bases":["SOP 022","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanki materiału siewnego Oznaczanie masy tysiąca nasion metodą wagową Směsi osiv Stanovení hmotnosti tisíce semen gravimetricky SOP 022, kap. 4.7 (Metodika zkoušení osiva a sadby, kap. 17.7; ISTA, kap. 18.7) Mieszanki materialu siewnego Oznaczanie masy tysiaca nasion metoda wagowa Smesi osiv Stanoveni hmotnosti tisice semen gravimetricky SOP 022, kap. 4.7 (Metodika zkouseni osiva a sadby, kap. 17.7; ISTA, kap. 18.7)","search_en":"Seed mixtures Determination of thousand seeds weight by gravimetric method SOP 022, kap. 4.7 (Metodika zkoušení osiva a sadby, kap. 17.7; ISTA, kap. 18.7)","search_zh":"混合种子 重量法测定千粒重 SOP 022, kap. 4.7 (Metodika zkoušení osiva a sadby, kap. 17.7; ISTA, kap. 18.7)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ddfe847629f6eaa285ef72e2","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"10","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osivo","methodology":"Oznaczanie zdolności kiełkowania metodą makroskopową","methodology_en":"Determination of germination by macroscopic method","methodology_zh":"宏观法测定发芽率","methodology_cs":"Stanovení klíčivosti makroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zdolności kiełkowania metodą makroskopową","reference":"SOP 009 (Metodika zkoušení osiva a sadby, kap. 5; ISTA, kap. 5)","norm_bases":["SOP 009","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny Oznaczanie zdolności kiełkowania metodą makroskopową Osivo Stanovení klíčivosti makroskopicky SOP 009 (Metodika zkoušení osiva a sadby, kap. 5; ISTA, kap. 5) Material siewny Oznaczanie zdolnosci kielkowania metoda makroskopowa Osivo Stanoveni klicivosti makroskopicky SOP 009 (Metodika zkouseni osiva a sadby, kap. 5; ISTA, kap. 5)","search_en":"Seed Determination of germination by macroscopic method SOP 009 (Metodika zkoušení osiva a sadby, kap. 5; ISTA, kap. 5)","search_zh":"种子 宏观法测定发芽率 SOP 009 (Metodika zkoušení osiva a sadby, kap. 5; ISTA, kap. 5)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f4284246817de98524bbe3aa","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"11","test_object":"Materiał siewny otoczkowany","test_object_en":"Coated seed","test_object_zh":"包衣种子","test_object_cs":"Obalované osivo","methodology":"Oznaczanie zdolności kiełkowania metodą makroskopową","methodology_en":"Determination of germination by macroscopic method","methodology_zh":"宏观法测定发芽率","methodology_cs":"Stanovení klíčivosti makroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zdolności kiełkowania metodą makroskopową","reference":"SOP 016, kap. 4.4 (Metodika zkoušení osiva a sadby, kap. 11.6; ISTA, kap. 11.5)","norm_bases":["SOP 016","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny otoczkowany Oznaczanie zdolności kiełkowania metodą makroskopową Obalované osivo Stanovení klíčivosti makroskopicky SOP 016, kap. 4.4 (Metodika zkoušení osiva a sadby, kap. 11.6; ISTA, kap. 11.5) Material siewny otoczkowany Oznaczanie zdolnosci kielkowania metoda makroskopowa Obalovane osivo Stanoveni klicivosti makroskopicky SOP 016, kap. 4.4 (Metodika zkouseni osiva a sadby, kap. 11.6; ISTA, kap. 11.5)","search_en":"Coated seed Determination of germination by macroscopic method SOP 016, kap. 4.4 (Metodika zkoušení osiva a sadby, kap. 11.6; ISTA, kap. 11.5)","search_zh":"包衣种子 宏观法测定发芽率 SOP 016, kap. 4.4 (Metodika zkoušení osiva a sadby, kap. 11.6; ISTA, kap. 11.5)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"08b35cb77bfdcb4b30a6a863","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"12","test_object":"Mieszanki materiału siewnego","test_object_en":"Seed mixtures","test_object_zh":"混合种子","test_object_cs":"Směsi osiv","methodology":"Oznaczanie zdolności kiełkowania metodą makroskopową","methodology_en":"Determination of germination by macroscopic method","methodology_zh":"宏观法测定发芽率","methodology_cs":"Stanovení klíčivosti makroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zdolności kiełkowania metodą makroskopową","reference":"SOP 022, kap. 4.6 (Metodika zkoušení osiva a sadby, kap. 17.6; ISTA, kap. 18.6)","norm_bases":["SOP 022","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanki materiału siewnego Oznaczanie zdolności kiełkowania metodą makroskopową Směsi osiv Stanovení klíčivosti makroskopicky SOP 022, kap. 4.6 (Metodika zkoušení osiva a sadby, kap. 17.6; ISTA, kap. 18.6) Mieszanki materialu siewnego Oznaczanie zdolnosci kielkowania metoda makroskopowa Smesi osiv Stanoveni klicivosti makroskopicky SOP 022, kap. 4.6 (Metodika zkouseni osiva a sadby, kap. 17.6; ISTA, kap. 18.6)","search_en":"Seed mixtures Determination of germination by macroscopic method SOP 022, kap. 4.6 (Metodika zkoušení osiva a sadby, kap. 17.6; ISTA, kap. 18.6)","search_zh":"混合种子 宏观法测定发芽率 SOP 022, kap. 4.6 (Metodika zkoušení osiva a sadby, kap. 17.6; ISTA, kap. 18.6)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5fa66825e9a694093a289384","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"13","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osivo","methodology":"Biochemiczna ocena żywotności metodą barwienia","methodology_en":"Biochemical test of viability by staining","methodology_zh":"染色法生化活力测定","methodology_cs":"Biochemická zkouška životaschopnosti barvením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Biochemiczna ocena żywotności metodą barwienia","reference":"SOP 010 (Metodika zkoušení osiva a sadby, kap. 6; ISTA, kap. 6)","norm_bases":["SOP 010","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny Biochemiczna ocena żywotności metodą barwienia Osivo Biochemická zkouška životaschopnosti barvením SOP 010 (Metodika zkoušení osiva a sadby, kap. 6; ISTA, kap. 6) Material siewny Biochemiczna ocena zywotnosci metoda barwienia Osivo Biochemicka zkouska zivotaschopnosti barvenim SOP 010 (Metodika zkouseni osiva a sadby, kap. 6; ISTA, kap. 6)","search_en":"Seed Biochemical test of viability by staining SOP 010 (Metodika zkoušení osiva a sadby, kap. 6; ISTA, kap. 6)","search_zh":"种子 染色法生化活力测定 SOP 010 (Metodika zkoušení osiva a sadby, kap. 6; ISTA, kap. 6)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b1212c124678dc3926e742c4","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"14","test_object":"Mieszanki materiału siewnego","test_object_en":"Seed mixtures","test_object_zh":"混合种子","test_object_cs":"Směsi osiv","methodology":"Biochemiczna ocena żywotności metodą barwienia","methodology_en":"Biochemical test of viability by staining","methodology_zh":"染色法生化活力测定","methodology_cs":"Biochemická zkouška životaschopnosti barvením","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Biochemiczna ocena żywotności metodą barwienia","reference":"SOP 022, kap. 4.6 (Metodika zkoušení osiva a sadby, kap. 17.6; ISTA, kap. 18.6)","norm_bases":["SOP 022","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanki materiału siewnego Biochemiczna ocena żywotności metodą barwienia Směsi osiv Biochemická zkouška životaschopnosti barvením SOP 022, kap. 4.6 (Metodika zkoušení osiva a sadby, kap. 17.6; ISTA, kap. 18.6) Mieszanki materialu siewnego Biochemiczna ocena zywotnosci metoda barwienia Smesi osiv Biochemicka zkouska zivotaschopnosti barvenim SOP 022, kap. 4.6 (Metodika zkouseni osiva a sadby, kap. 17.6; ISTA, kap. 18.6)","search_en":"Seed mixtures Biochemical test of viability by staining SOP 022, kap. 4.6 (Metodika zkoušení osiva a sadby, kap. 17.6; ISTA, kap. 18.6)","search_zh":"混合种子 染色法生化活力测定 SOP 022, kap. 4.6 (Metodika zkoušení osiva a sadby, kap. 17.6; ISTA, kap. 18.6)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4df730902b714be279bf754f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"15","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osivo","methodology":"Oznaczanie występowania chorób metodą makroskopową i mikroskopową","methodology_en":"Detection of diseases by macroscopic and microscopic method","methodology_zh":"宏观和显微镜法测定病害发生","methodology_cs":"Stanovení výskytu chorob makroskopicky a mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie występowania chorób metodą makroskopową i mikroskopową","reference":"SOP 011 (Metodika zkoušení osiva a sadby, kap. 7; ISTA, kap. 7)","norm_bases":["SOP 011","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny Oznaczanie występowania chorób metodą makroskopową i mikroskopową Osivo Stanovení výskytu chorob makroskopicky a mikroskopicky SOP 011 (Metodika zkoušení osiva a sadby, kap. 7; ISTA, kap. 7) Material siewny Oznaczanie wystepowania chorob metoda makroskopowa i mikroskopowa Osivo Stanoveni vyskytu chorob makroskopicky a mikroskopicky SOP 011 (Metodika zkouseni osiva a sadby, kap. 7; ISTA, kap. 7)","search_en":"Seed Detection of diseases by macroscopic and microscopic method SOP 011 (Metodika zkoušení osiva a sadby, kap. 7; ISTA, kap. 7)","search_zh":"种子 宏观和显微镜法测定病害发生 SOP 011 (Metodika zkoušení osiva a sadby, kap. 7; ISTA, kap. 7)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e42c723926bb1d5918a968f6","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"16","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osivo","methodology":"Określanie tożsamości gatunku i odmiany","methodology_en":"Determining the identity of species and variety","methodology_zh":"种和品种真实性鉴定","methodology_cs":"Určování pravosti druhu a odrůdy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Określanie tożsamości gatunku i odmiany","reference":"SOP 012 (Metodika zkoušení osiva a sadby, kap. 8.10; PRESLIA 1963 35:210-216 Jaroslav Pazourek)","norm_bases":["SOP 012","Metodika zkoušení osiva a sadby","PRESLIA 1963 35:210-216 Jaroslav Pazourek"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Uszczegółowienie: wyłącznie do rozróżniania: owsa białego od owsa żółtego, nasion łubinu o wysokiej zawartości substancji gorzkich, nasion kapustowatych, buraka cukrowego, pastewnego i ćwikłowego wg barwy hipokotylu","note_en":"Specification: Only for distinguishing: white oats from yellow oats, lupine seeds with a high content of bitter substances, cruciferous seeds, sugar beet, fodder and salad beet by the colour of the hypocotyl","note_zh":"细化说明：仅用于区分：白燕麦与黄燕麦、高苦味物质含量的羽扇豆种子、十字花科种子、糖用甜菜、饲用甜菜和食用甜菜（按下胚轴颜色）","note_cs":"Upřesnění: Pouze pro rozlišování: ovsa bílého od ovsa žlutého, semen lupiny s vysokým obsahem hořkých látek, brukvovitých semen, cukrovky, krmné a salátové řepy podle barvy hypokotylu","search_text":"Materiał siewny Określanie tożsamości gatunku i odmiany Osivo Určování pravosti druhu a odrůdy SOP 012 (Metodika zkoušení osiva a sadby, kap. 8.10; PRESLIA 1963 35:210-216 Jaroslav Pazourek) Material siewny Okreslanie tozsamosci gatunku i odmiany Osivo Urcovani pravosti druhu a odrudy SOP 012 (Metodika zkouseni osiva a sadby, kap. 8.10; PRESLIA 1963 35:210-216 Jaroslav Pazourek)","search_en":"Seed Determining the identity of species and variety SOP 012 (Metodika zkoušení osiva a sadby, kap. 8.10; PRESLIA 1963 35:210-216 Jaroslav Pazourek)","search_zh":"种子 种和品种真实性鉴定 SOP 012 (Metodika zkoušení osiva a sadby, kap. 8.10; PRESLIA 1963 35:210-216 Jaroslav Pazourek)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f223ce3de54e53c0bfc8314f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"17","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osivo","methodology":"Oznaczanie stopnia ploidalności metodą mikroskopową","methodology_en":"Determining the degree of ploidy microscopically","methodology_zh":"显微镜法测定倍性","methodology_cs":"Stanovení stupně ploidie mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stopnia ploidalności metodą mikroskopową","reference":"SOP 013 (Metodika zkoušení osiva a sadby, kap. 8.9; Soubor karyologických metodik u vybraných druhů kulturních rostlin)","norm_bases":["SOP 013","Metodika zkoušení osiva a sadby","Soubor karyologických metodik u vybraných druhů kulturních rostlin"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny Oznaczanie stopnia ploidalności metodą mikroskopową Osivo Stanovení stupně ploidie mikroskopicky SOP 013 (Metodika zkoušení osiva a sadby, kap. 8.9; Soubor karyologických metodik u vybraných druhů kulturních rostlin) Material siewny Oznaczanie stopnia ploidalnosci metoda mikroskopowa Osivo Stanoveni stupne ploidie mikroskopicky SOP 013 (Metodika zkouseni osiva a sadby, kap. 8.9; Soubor karyologickych metodik u vybranych druhu kulturnich rostlin)","search_en":"Seed Determining the degree of ploidy microscopically SOP 013 (Metodika zkoušení osiva a sadby, kap. 8.9; Soubor karyologických metodik u vybraných druhů kulturních rostlin)","search_zh":"种子 显微镜法测定倍性 SOP 013 (Metodika zkoušení osiva a sadby, kap. 8.9; Soubor karyologických metodik u vybraných druhů kulturních rostlin)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"44342d62d47f766d501e5611","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"18","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osivo","methodology":"Badanie jakości zaprawiania","methodology_en":"Testing the quality of seed treatment","methodology_zh":"种子包衣处理质量检测","methodology_cs":"Zkoušení kvality namoření","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie jakości zaprawiania","reference":"SOP 023 (Metodika zkoušení osiva a sadby, kap. 7; ISTA, kap. 7)","norm_bases":["SOP 023","Metodika zkoušení osiva a sadby","ISTA"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał siewny Badanie jakości zaprawiania Osivo Zkoušení kvality namoření SOP 023 (Metodika zkoušení osiva a sadby, kap. 7; ISTA, kap. 7) Material siewny Badanie jakosci zaprawiania Osivo Zkouseni kvality namoreni SOP 023 (Metodika zkouseni osiva a sadby, kap. 7; ISTA, kap. 7)","search_en":"Seed Testing the quality of seed treatment SOP 023 (Metodika zkoušení osiva a sadby, kap. 7; ISTA, kap. 7)","search_zh":"种子 种子包衣处理质量检测 SOP 023 (Metodika zkoušení osiva a sadby, kap. 7; ISTA, kap. 7)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"15fb01b52500cb1b6b4b93a3","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"19","test_object":"Pszenica, jęczmień, pszenżyto, owies, życica, groch","test_object_en":"Wheat, barley, triticale, oats, ryegrass, peas","test_object_zh":"小麦、大麦、黑小麦、燕麦、黑麦草、豌豆","test_object_cs":"Pšenice, ječmen, tritikale, oves, jílek, hrách","methodology":"Weryfikacja tożsamości i czystości odmianowej i gatunkowej metodą elektroforezy pionowej","methodology_en":"Verification of varietal and species identity and purity by vertical electrophoresis","methodology_zh":"垂直电泳法验证品种和种的真实性与纯度","methodology_cs":"Ověřování pravosti a čistoty odrůdy a druhu vertikální elektroforézou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Weryfikacja tożsamości i czystości odmianowej i gatunkowej metodą elektroforezy pionowej","reference":"SOP 015 (Metodika zkoušení osiva a sadby, kap. 8.8; ISTA, kap. 8.9.6, 8.9.1, 8.9.7, 8.9.4, 8.9.2; UPOV, TG 23/6)","norm_bases":["SOP 015","Metodika zkoušení osiva a sadby","ISTA","UPOV, TG 23/6"],"lab_section":"ÚKZÚZ, NRL, Dział NRL OS","lab_section_en":"ÚKZÚZ, NRL, Department of NRL OS","lab_section_zh":"ÚKZÚZ, NRL，NRL OS科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL OS","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pszenica, jęczmień, pszenżyto, owies, życica, groch Weryfikacja tożsamości i czystości odmianowej i gatunkowej metodą elektroforezy pionowej Pšenice, ječmen, tritikale, oves, jílek, hrách Ověřování pravosti a čistoty odrůdy a druhu vertikální elektroforézou SOP 015 (Metodika zkoušení osiva a sadby, kap. 8.8; ISTA, kap. 8.9.6, 8.9.1, 8.9.7, 8.9.4, 8.9.2; UPOV, TG 23/6) Pszenica, jeczmien, pszenzyto, owies, zycica, groch Weryfikacja tozsamosci i czystosci odmianowej i gatunkowej metoda elektroforezy pionowej Psenice, jecmen, tritikale, oves, jilek, hrach Overovani pravosti a cistoty odrudy a druhu vertikalni elektroforezou SOP 015 (Metodika zkouseni osiva a sadby, kap. 8.8; ISTA, kap. 8.9.6, 8.9.1, 8.9.7, 8.9.4, 8.9.2; UPOV, TG 23/6)","search_en":"Wheat, barley, triticale, oats, ryegrass, peas Verification of varietal and species identity and purity by vertical electrophoresis SOP 015 (Metodika zkoušení osiva a sadby, kap. 8.8; ISTA, kap. 8.9.6, 8.9.1, 8.9.7, 8.9.4, 8.9.2; UPOV, TG 23/6)","search_zh":"小麦、大麦、黑小麦、燕麦、黑麦草、豌豆 垂直电泳法验证品种和种的真实性与纯度 SOP 015 (Metodika zkoušení osiva a sadby, kap. 8.8; ISTA, kap. 8.9.6, 8.9.1, 8.9.7, 8.9.4, 8.9.2; UPOV, TG 23/6)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"862ede2b4f62db21ce1d9ff7","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"1","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP ÚKZÚZ, 10001.1","norm_bases":["JPP ÚKZÚZ, 10001.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Krmiva a suroviny pro jejich výrobu Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP ÚKZÚZ, 10001.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 10001.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of moisture by gravimetric method and calculation of dry matter JPP ÚKZÚZ, 10001.1","search_zh":"饲料及其生产原料 重量法测定水分含量并计算干物质 JPP ÚKZÚZ, 10001.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2c6e0b3268c826959d8b4f9f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"2","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości tłuszczu i tłuszczu po hydrolizie metodą wagową","methodology_en":"Determination of fat and fat after hydrolysis by gravimetric method","methodology_zh":"重量法测定脂肪和水解后脂肪含量","methodology_cs":"Stanovení obsahu tuku a tuku po hydrolýze gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości tłuszczu i tłuszczu po hydrolizie metodą wagową","reference":"JPP ÚKZÚZ, 10058.1","norm_bases":["JPP ÚKZÚZ, 10058.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości tłuszczu i tłuszczu po hydrolizie metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu tuku a tuku po hydrolýze gravimetricky JPP ÚKZÚZ, 10058.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci tluszczu i tluszczu po hydrolizie metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu tuku a tuku po hydrolyze gravimetricky JPP UKZUZ, 10058.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of fat and fat after hydrolysis by gravimetric method JPP ÚKZÚZ, 10058.1","search_zh":"饲料及其生产原料 重量法测定脂肪和水解后脂肪含量 JPP ÚKZÚZ, 10058.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"396e66d63b756258cd41cb61","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"3","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości włókna metodą wagową","methodology_en":"Determination of fibre by gravimetric method","methodology_zh":"重量法测定纤维含量","methodology_cs":"Stanovení obsahu vlákniny gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości włókna metodą wagową","reference":"JPP ÚKZÚZ, 10068.1","norm_bases":["JPP ÚKZÚZ, 10068.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości włókna metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu vlákniny gravimetricky JPP ÚKZÚZ, 10068.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wlokna metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vlakniny gravimetricky JPP UKZUZ, 10068.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of fibre by gravimetric method JPP ÚKZÚZ, 10068.1","search_zh":"饲料及其生产原料 重量法测定纤维含量 JPP ÚKZÚZ, 10068.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9508b956dc54be7dc725a87a","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"4","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości popiołu i substancji palnych metodą wagową","methodology_en":"Determination of ash and combustible substances by gravimetric method","methodology_zh":"重量法测定灰分和可燃物含量","methodology_cs":"Stanovení obsahu popela a obsahu spalitelných látek gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości popiołu i substancji palnych metodą wagową","reference":"JPP ÚKZÚZ, 10004.1","norm_bases":["JPP ÚKZÚZ, 10004.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości popiołu i substancji palnych metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu popela a obsahu spalitelných látek gravimetricky JPP ÚKZÚZ, 10004.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci popiolu i substancji palnych metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu popela a obsahu spalitelnych latek gravimetricky JPP UKZUZ, 10004.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of ash and combustible substances by gravimetric method JPP ÚKZÚZ, 10004.1","search_zh":"饲料及其生产原料 重量法测定灰分和可燃物含量 JPP ÚKZÚZ, 10004.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ad1055385c048c3b56e0ecaf","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"5","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości azotu miareczkowo i substancji azotowych obliczeniowo z wyników pomiarów","methodology_en":"Determination of the content of nitrogen by titrimetric method and nitrogenous substances by calculation from measured values","methodology_zh":"滴定法测定氮含量并由测量值计算含氮物质","methodology_cs":"Stanovení obsahu dusíku titračně a dusíkatých látek výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu miareczkowo i substancji azotowych obliczeniowo z wyników pomiarów","reference":"JPP ÚKZÚZ, 10014.1","norm_bases":["JPP ÚKZÚZ, 10014.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Uszczegółowienie: wyraża się jako: substancje azotowe (współczynnik), substancje azotowe (współczynnik) w suchej masie, azot (N) całkowity, współczynnik = przelicznik dla substancji azotowych","note_en":"Specification: Expressed as: nitrogenous substances (factor), nitrogenous substances (factor) in dry matter, total nitrogen (N), factor = conversion factor for nitrogenous substances","note_zh":"细化说明：表示形式：含氮物质（系数）、干物质中含氮物质（系数）、总氮（N），系数=含氮物质换算系数","note_cs":"Upřesnění: Vyjadřuje se formou: dusíkaté látky (faktor), dusíkaté látky (faktor) v sušině, dusík (N) celkový, faktor = přepočtový faktor pro dusíkaté látky","search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości azotu miareczkowo i substancji azotowych obliczeniowo z wyników pomiarów Krmiva a suroviny pro jejich výrobu Stanovení obsahu dusíku titračně a dusíkatých látek výpočtem z naměřených hodnot JPP ÚKZÚZ, 10014.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci azotu miareczkowo i substancji azotowych obliczeniowo z wynikow pomiarow Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu dusiku titracne a dusikatych latek vypoctem z namerenych hodnot JPP UKZUZ, 10014.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of the content of nitrogen by titrimetric method and nitrogenous substances by calculation from measured values JPP ÚKZÚZ, 10014.1","search_zh":"饲料及其生产原料 滴定法测定氮含量并由测量值计算含氮物质 JPP ÚKZÚZ, 10014.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"29a51a0513ff3cd63ac994e5","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"6","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości chlorków miareczkowo","methodology_en":"Determination of chlorides by titrimetric method","methodology_zh":"滴定法测定氯化物含量","methodology_cs":"Stanovení obsahu chloridů titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości chlorków miareczkowo","reference":"JPP ÚKZÚZ, 10131.1","norm_bases":["JPP ÚKZÚZ, 10131.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Uszczegółowienie: wyraża się jako: chlorki jako NaCl","note_en":"Specification: Expressed as: chlorides as NaCl","note_zh":"细化说明：表示形式：以NaCl计的氯化物","note_cs":"Upřesnění: Vyjadřuje se formou: chloridy jako NaCl","search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości chlorków miareczkowo Krmiva a suroviny pro jejich výrobu Stanovení obsahu chloridů titračně JPP ÚKZÚZ, 10131.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci chlorkow miareczkowo Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu chloridu titracne JPP UKZUZ, 10131.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of chlorides by titrimetric method JPP ÚKZÚZ, 10131.1","search_zh":"饲料及其生产原料 滴定法测定氯化物含量 JPP ÚKZÚZ, 10131.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"89dae3e9ff5e0874a9108d11","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"7","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości cukrów miareczkowo","methodology_en":"Determination of sugars by titrimetric method","methodology_zh":"滴定法测定糖含量","methodology_cs":"Stanovení obsahu cukrů titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości cukrów miareczkowo","reference":"JPP ÚKZÚZ, 10084.1","norm_bases":["JPP ÚKZÚZ, 10084.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Uszczegółowienie: wyraża się jako: cukry ogółem po hydrolizie jako sacharoza, cukry nieredukujące jako sacharoza, cukry redukujące jako fruktoza, jako glukoza, jako cukier inwertowany, jako maltoza, jako laktoza","note_en":"Specification: Expressed as: total sugars after hydrolysis as saccharose, non-reducing sugars as saccharose, reducing sugars as fructose, reducing sugars as glucose, reducing sugars as invert, reducing sugars as maltose, reducing sugars as lactose","note_zh":"细化说明：表示形式：水解后总糖（以蔗糖计）、非还原糖（以蔗糖计）、还原糖（以果糖、葡萄糖、转化糖、麦芽糖、乳糖计）","note_cs":"Upřesnění: Vyjadřuje se formou: cukry celkové po hydrolýze jako sacharosa, cukry neredukující jako sacharosa, cukry redukující jako fruktosa, cukry redukující jako glukosa, cukry redukující jako invert, cukry redukující jako maltosa, cukry redukující jako laktosa","search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości cukrów miareczkowo Krmiva a suroviny pro jejich výrobu Stanovení obsahu cukrů titračně JPP ÚKZÚZ, 10084.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci cukrow miareczkowo Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu cukru titracne JPP UKZUZ, 10084.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of sugars by titrimetric method JPP ÚKZÚZ, 10084.1","search_zh":"饲料及其生产原料 滴定法测定糖含量 JPP ÚKZÚZ, 10084.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4af2b4982aa9edca13012013","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"8","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie całkowitej zawartości fosforu metodą spektrofotometryczną","methodology_en":"Determination of total phosphorus by spectrophotometric method","methodology_zh":"分光光度法测定总磷含量","methodology_cs":"Stanovení celkového obsahu fosforu spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie całkowitej zawartości fosforu metodą spektrofotometryczną","reference":"JPP ÚKZÚZ, 10122.1","norm_bases":["JPP ÚKZÚZ, 10122.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie całkowitej zawartości fosforu metodą spektrofotometryczną Krmiva a suroviny pro jejich výrobu Stanovení celkového obsahu fosforu spektrofotometricky JPP ÚKZÚZ, 10122.1 Pasze i surowce do ich produkcji Oznaczanie calkowitej zawartosci fosforu metoda spektrofotometryczna Krmiva a suroviny pro jejich vyrobu Stanoveni celkoveho obsahu fosforu spektrofotometricky JPP UKZUZ, 10122.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of total phosphorus by spectrophotometric method JPP ÚKZÚZ, 10122.1","search_zh":"饲料及其生产原料 分光光度法测定总磷含量 JPP ÚKZÚZ, 10122.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5552aa629335f8555fe5f73c","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"9","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą FAAS","methodology_en":"Determination of selected elements by FAAS method","methodology_zh":"FAAS法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou FAAS","parameters":[{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"锰（Mn）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"Mn","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą FAAS\nZakres:\nMiedź (Cu)\nŻelazo (Fe)\nMangan (Mn)\nCynk (Zn)","reference":"JPP ÚKZÚZ, 10325.1","norm_bases":["JPP ÚKZÚZ, 10325.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wybranych pierwiastków metodą FAAS Miedź (Cu)  Żelazo (Fe)  Mangan (Mn)  Cynk (Zn)  Krmiva a suroviny pro jejich výrobu Stanovení obsahu vybraných prvků metodou FAAS Cu  Fe  Mn  Zn  JPP ÚKZÚZ, 10325.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wybranych pierwiastkow metoda FAAS Miedz (Cu)  Zelazo (Fe)  Mangan (Mn)  Cynk (Zn)  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vybranych prvku metodou FAAS Cu  Fe  Mn  Zn  JPP UKZUZ, 10325.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of selected elements by FAAS method Copper (Cu)  Iron (Fe)  Manganese (Mn)  Zinc (Zn)  JPP ÚKZÚZ, 10325.1","search_zh":"饲料及其生产原料 FAAS法测定选定元素含量 铜（Cu）  铁（Fe）  锰（Mn）  锌（Zn）  JPP ÚKZÚZ, 10325.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"50ba46bfc540a27771e3ecf5","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"10","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wybranych makropierwiastków metodą FAAS i FAES","methodology_en":"Determination of selected macroelements by FAAS and FAES method","methodology_zh":"FAAS和FAES法测定选定常量元素含量","methodology_cs":"Stanovení obsahu vybraných makroprvků metodou FAAS a FAES","parameters":[{"name":"Wapń (Ca)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Sód (Na)","range":""}],"parameters_en":[{"name":"Calcium (Ca)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Sodium (Na)","range":""}],"parameters_zh":[{"name":"钙（Ca）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"钠（Na）","range":""}],"parameters_cs":[{"name":"Ca","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Na","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych makropierwiastków metodą FAAS i FAES\nZakres:\nWapń (Ca)\nPotas (K)\nMagnez (Mg)\nSód (Na)","reference":"JPP ÚKZÚZ, 10135.1","norm_bases":["JPP ÚKZÚZ, 10135.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wybranych makropierwiastków metodą FAAS i FAES Wapń (Ca)  Potas (K)  Magnez (Mg)  Sód (Na)  Krmiva a suroviny pro jejich výrobu Stanovení obsahu vybraných makroprvků metodou FAAS a FAES Ca  K  Mg  Na  JPP ÚKZÚZ, 10135.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wybranych makropierwiastkow metoda FAAS i FAES Wapn (Ca)  Potas (K)  Magnez (Mg)  Sod (Na)  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vybranych makroprvku metodou FAAS a FAES Ca  K  Mg  Na  JPP UKZUZ, 10135.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of selected macroelements by FAAS and FAES method Calcium (Ca)  Potassium (K)  Magnesium (Mg)  Sodium (Na)  JPP ÚKZÚZ, 10135.1","search_zh":"饲料及其生产原料 FAAS和FAES法测定选定常量元素含量 钙（Ca）  钾（K）  镁（Mg）  钠（Na）  JPP ÚKZÚZ, 10135.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"88e7252e2feb434d27e3295e","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"11","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości witaminy A, E metodą HPLC/DAD, FLD","methodology_en":"Determination of vitamin A, E by HPLC/DAD, FLD method","methodology_zh":"HPLC/DAD、FLD法测定维生素A、E含量","methodology_cs":"Stanovení obsahu vitamínu A, E metodou HPLC/DAD, FLD","parameters":[{"name":"Witamina A – retinol całkowity (all cis trans)","range":""},{"name":"Witamina E – DL-alfa-tokoferol","range":""},{"name":"Witamina E – octan DL-alfa-tokoferolu","range":""}],"parameters_en":[{"name":"Vitamin A – total retinol (all cis trans)","range":""},{"name":"Vitamin E – DL-alpha-tocopherol","range":""},{"name":"Vitamin E – DL-alpha-tocopherolacetate","range":""}],"parameters_zh":[{"name":"维生素A——总视黄醇（全顺反式）","range":""},{"name":"维生素E——DL-α-生育酚","range":""},{"name":"维生素E——DL-α-生育酚乙酸酯","range":""}],"parameters_cs":[{"name":"Vitamin A - celk. retinol (all cis trans)","range":""},{"name":"Vitamin E - DL-alfa-tokoferol","range":""},{"name":"Vitamin E - DL-alfa-tokoferolacetát","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości witaminy A, E metodą HPLC/DAD, FLD\nZakres:\nWitamina A – retinol całkowity (all cis trans)\nWitamina E – DL-alfa-tokoferol\nWitamina E – octan DL-alfa-tokoferolu","reference":"JPP ÚKZÚZ, 10380.1","norm_bases":["JPP ÚKZÚZ, 10380.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości witaminy A, E metodą HPLC/DAD, FLD Witamina A – retinol całkowity (all cis trans)  Witamina E – DL-alfa-tokoferol  Witamina E – octan DL-alfa-tokoferolu  Krmiva a suroviny pro jejich výrobu Stanovení obsahu vitamínu A, E metodou HPLC/DAD, FLD Vitamin A - celk. retinol (all cis trans)  Vitamin E - DL-alfa-tokoferol  Vitamin E - DL-alfa-tokoferolacetát  JPP ÚKZÚZ, 10380.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci witaminy A, E metoda HPLC/DAD, FLD Witamina A – retinol calkowity (all cis trans)  Witamina E – DL-alfa-tokoferol  Witamina E – octan DL-alfa-tokoferolu  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vitaminu A, E metodou HPLC/DAD, FLD Vitamin A - celk. retinol (all cis trans)  Vitamin E - DL-alfa-tokoferol  Vitamin E - DL-alfa-tokoferolacetat  JPP UKZUZ, 10380.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of vitamin A, E by HPLC/DAD, FLD method Vitamin A – total retinol (all cis trans)  Vitamin E – DL-alpha-tocopherol  Vitamin E – DL-alpha-tocopherolacetate  JPP ÚKZÚZ, 10380.1","search_zh":"饲料及其生产原料 HPLC/DAD、FLD法测定维生素A、E含量 维生素A——总视黄醇（全顺反式）  维生素E——DL-α-生育酚  维生素E——DL-α-生育酚乙酸酯  JPP ÚKZÚZ, 10380.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"813ed49cf8efc00eb2b2fdc9","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"12","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości amprolium metodą HPLC/UV","methodology_en":"Determination of amprolium by HPLC/UV method","methodology_zh":"HPLC/UV法测定氨丙啉含量","methodology_cs":"Stanovení obsahu amprolia metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości amprolium metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10636.1","norm_bases":["JPP ÚKZÚZ, 10636.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości amprolium metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení obsahu amprolia metodou HPLC/UV JPP ÚKZÚZ, 10636.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci amprolium metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu amprolia metodou HPLC/UV JPP UKZUZ, 10636.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of amprolium by HPLC/UV method JPP ÚKZÚZ, 10636.1","search_zh":"饲料及其生产原料 HPLC/UV法测定氨丙啉含量 JPP ÚKZÚZ, 10636.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"478c3176fc12d883d9f90d17","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"13","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości robenidyny metodą HPLC/UV","methodology_en":"Determination of robenidin by HPLC/UV method","methodology_zh":"HPLC/UV法测定罗贝胍含量","methodology_cs":"Stanovení obsahu robenidinu metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości robenidyny metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10394.1","norm_bases":["JPP ÚKZÚZ, 10394.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości robenidyny metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení obsahu robenidinu metodou HPLC/UV JPP ÚKZÚZ, 10394.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci robenidyny metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu robenidinu metodou HPLC/UV JPP UKZUZ, 10394.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of robenidin by HPLC/UV method JPP ÚKZÚZ, 10394.1","search_zh":"饲料及其生产原料 HPLC/UV法测定罗贝胍含量 JPP ÚKZÚZ, 10394.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"71a9eb87d391b73c368d25cd","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"14","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości diklazurylu metodą HPLC/UV","methodology_en":"Determination of diclazuril by HPLC/UV method","methodology_zh":"HPLC/UV法测定地克珠利含量","methodology_cs":"Stanovení obsahu diclazurilu metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości diklazurylu metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10393.1","norm_bases":["JPP ÚKZÚZ, 10393.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości diklazurylu metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení obsahu diclazurilu metodou HPLC/UV JPP ÚKZÚZ, 10393.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci diklazurylu metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu diclazurilu metodou HPLC/UV JPP UKZUZ, 10393.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of diclazuril by HPLC/UV method JPP ÚKZÚZ, 10393.1","search_zh":"饲料及其生产原料 HPLC/UV法测定地克珠利含量 JPP ÚKZÚZ, 10393.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6ddd58ed3ded45ba0f0b31ac","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"15","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wybranych dodatków paszowych metodą HPLC/UV","methodology_en":"Determination of selected feed additives by HPLC/UV method","methodology_zh":"HPLC/UV法测定选定饲料添加剂含量","methodology_cs":"Stanovení obsahu vybraných doplňkových látek metodou HPLC/UV","parameters":[{"name":"Monenzyna sodowa","range":""},{"name":"salinomycyna sodowa","range":""},{"name":"narazyna","range":""}],"parameters_en":[{"name":"Monensin sodium","range":""},{"name":"salinomycin sodium","range":""},{"name":"narasin","range":""}],"parameters_zh":[{"name":"莫能菌素钠","range":""},{"name":"盐霉素钠","range":""},{"name":"甲基盐霉素","range":""}],"parameters_cs":[{"name":"Monensinát sodný","range":""},{"name":"salinomycinát sodný","range":""},{"name":"narasin","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych dodatków paszowych metodą HPLC/UV\nZakres:\nMonenzyna sodowa\nsalinomycyna sodowa\nnarazyna","reference":"JPP ÚKZÚZ, 10350.1","norm_bases":["JPP ÚKZÚZ, 10350.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wybranych dodatków paszowych metodą HPLC/UV Monenzyna sodowa  salinomycyna sodowa  narazyna  Krmiva a suroviny pro jejich výrobu Stanovení obsahu vybraných doplňkových látek metodou HPLC/UV Monensinát sodný  salinomycinát sodný  narasin  JPP ÚKZÚZ, 10350.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wybranych dodatkow paszowych metoda HPLC/UV Monenzyna sodowa  salinomycyna sodowa  narazyna  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vybranych doplnkovych latek metodou HPLC/UV Monensinat sodny  salinomycinat sodny  narasin  JPP UKZUZ, 10350.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of selected feed additives by HPLC/UV method Monensin sodium  salinomycin sodium  narasin  JPP ÚKZÚZ, 10350.1","search_zh":"饲料及其生产原料 HPLC/UV法测定选定饲料添加剂含量 莫能菌素钠  盐霉素钠  甲基盐霉素  JPP ÚKZÚZ, 10350.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cef59a53fce5a465b7ee6e35","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"16","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości lasalocydu sodowego metodą HPLC/FLD","methodology_en":"Determination of lasalocid sodium by HPLC/FLD method","methodology_zh":"HPLC/FLD法测定拉沙洛西钠含量","methodology_cs":"Stanovení obsahu lasalocidu sodného metodou HPLC/FLD","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości lasalocydu sodowego metodą HPLC/FLD","reference":"JPP ÚKZÚZ, 10400.1","norm_bases":["JPP ÚKZÚZ, 10400.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości lasalocydu sodowego metodą HPLC/FLD Krmiva a suroviny pro jejich výrobu Stanovení obsahu lasalocidu sodného metodou HPLC/FLD JPP ÚKZÚZ, 10400.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci lasalocydu sodowego metoda HPLC/FLD Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu lasalocidu sodneho metodou HPLC/FLD JPP UKZUZ, 10400.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of lasalocid sodium by HPLC/FLD method JPP ÚKZÚZ, 10400.1","search_zh":"饲料及其生产原料 HPLC/FLD法测定拉沙洛西钠含量 JPP ÚKZÚZ, 10400.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"676fd58557a44c7c8e1adfb4","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"17","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości dimetridazolu metodą HPLC/UV","methodology_en":"Determination of dimetridazole by HPLC/UV method","methodology_zh":"HPLC/UV法测定二甲硝咪唑含量","methodology_cs":"Stanovení obsahu dimetridazolu metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości dimetridazolu metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10391.1","norm_bases":["JPP ÚKZÚZ, 10391.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości dimetridazolu metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení obsahu dimetridazolu metodou HPLC/UV JPP ÚKZÚZ, 10391.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci dimetridazolu metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu dimetridazolu metodou HPLC/UV JPP UKZUZ, 10391.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of dimetridazole by HPLC/UV method JPP ÚKZÚZ, 10391.1","search_zh":"饲料及其生产原料 HPLC/UV法测定二甲硝咪唑含量 JPP ÚKZÚZ, 10391.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e0a0bedf7aaf67dac6ec7bec","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"18","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości nikarbazyny metodą HPLC/UV","methodology_en":"Determination of nicarbazin by HPLC/UV method","methodology_zh":"HPLC/UV法测定尼卡巴嗪含量","methodology_cs":"Stanovení obsahu nikarbazinu metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości nikarbazyny metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10360.1","norm_bases":["JPP ÚKZÚZ, 10360.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości nikarbazyny metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení obsahu nikarbazinu metodou HPLC/UV JPP ÚKZÚZ, 10360.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci nikarbazyny metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu nikarbazinu metodou HPLC/UV JPP UKZUZ, 10360.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of nicarbazin by HPLC/UV method JPP ÚKZÚZ, 10360.1","search_zh":"饲料及其生产原料 HPLC/UV法测定尼卡巴嗪含量 JPP ÚKZÚZ, 10360.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"690be1653a4ea10ec13bda51","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"19","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości kokcydiostatyków metodą LC-MS/MS","methodology_en":"Determination of coccidiostats by LC-MS/MS method","methodology_zh":"LC-MS/MS法测定抗球虫药含量","methodology_cs":"Stanovení obsahu kokcidiostatik metodou LC-MS/MS","parameters":[{"name":"Chlorowodorek robenidyny","range":""},{"name":"monenzyna sodowa","range":""},{"name":"salinomycyna sodowa","range":""},{"name":"narazyna","range":""},{"name":"lasalocyd sodowy","range":""},{"name":"bromowodorek halofuginonu","range":""},{"name":"semduramycyna sodowa","range":""},{"name":"maduramycyna amonowa alfa","range":""},{"name":"diklazuryl","range":""},{"name":"nikarbazyna","range":""},{"name":"dekokwinat","range":""},{"name":"dimetridazol","range":""}],"parameters_en":[{"name":"Robenidin hydrochloride","range":""},{"name":"monensin sodium","range":""},{"name":"salinomycin sodium","range":""},{"name":"narasin","range":""},{"name":"lasalocid sodium","range":""},{"name":"halofuginon hydrobromide","range":""},{"name":"semduramicin sodium","range":""},{"name":"maduramicin ammonium alpha","range":""},{"name":"diclazuril","range":""},{"name":"nicarbazin","range":""},{"name":"decoquinate","range":""},{"name":"dimetridazole","range":""}],"parameters_zh":[{"name":"盐酸罗贝胍","range":""},{"name":"莫能菌素钠","range":""},{"name":"盐霉素钠","range":""},{"name":"甲基盐霉素","range":""},{"name":"拉沙洛西钠","range":""},{"name":"氢溴酸常山酮","range":""},{"name":"赛杜霉素钠","range":""},{"name":"马度米星铵α","range":""},{"name":"地克珠利","range":""},{"name":"尼卡巴嗪","range":""},{"name":"癸氧喹酯","range":""},{"name":"二甲硝咪唑","range":""}],"parameters_cs":[{"name":"Robenidin hydrochlorid","range":""},{"name":"monensinát sodný","range":""},{"name":"salinomycinát sodný","range":""},{"name":"narasin","range":""},{"name":"lasalocid sodný","range":""},{"name":"halofuginon hydrobromid","range":""},{"name":"semduramicinát sodný","range":""},{"name":"maduramicin ammonium alfa","range":""},{"name":"diclazuril","range":""},{"name":"nikarbazin","range":""},{"name":"dekochinát","range":""},{"name":"dimetridazol","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości kokcydiostatyków metodą LC-MS/MS\nZakres:\nChlorowodorek robenidyny\nmonenzyna sodowa\nsalinomycyna sodowa\nnarazyna\nlasalocyd sodowy\nbromowodorek halofuginonu\nsemduramycyna sodowa\nmaduramycyna amonowa alfa\ndiklazuryl\nnikarbazyna\ndekokwinat\ndimetridazol","reference":"JPP ÚKZÚZ, 10620.3","norm_bases":["JPP ÚKZÚZ, 10620.3"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości kokcydiostatyków metodą LC-MS/MS Chlorowodorek robenidyny  monenzyna sodowa  salinomycyna sodowa  narazyna  lasalocyd sodowy  bromowodorek halofuginonu  semduramycyna sodowa  maduramycyna amonowa alfa  diklazuryl  nikarbazyna  dekokwinat  dimetridazol  Krmiva a suroviny pro jejich výrobu Stanovení obsahu kokcidiostatik metodou LC-MS/MS Robenidin hydrochlorid  monensinát sodný  salinomycinát sodný  narasin  lasalocid sodný  halofuginon hydrobromid  semduramicinát sodný  maduramicin ammonium alfa  diclazuril  nikarbazin  dekochinát  dimetridazol  JPP ÚKZÚZ, 10620.3 Pasze i surowce do ich produkcji Oznaczanie zawartosci kokcydiostatykow metoda LC-MS/MS Chlorowodorek robenidyny  monenzyna sodowa  salinomycyna sodowa  narazyna  lasalocyd sodowy  bromowodorek halofuginonu  semduramycyna sodowa  maduramycyna amonowa alfa  diklazuryl  nikarbazyna  dekokwinat  dimetridazol  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu kokcidiostatik metodou LC-MS/MS Robenidin hydrochlorid  monensinat sodny  salinomycinat sodny  narasin  lasalocid sodny  halofuginon hydrobromid  semduramicinat sodny  maduramicin ammonium alfa  diclazuril  nikarbazin  dekochinat  dimetridazol  JPP UKZUZ, 10620.3","search_en":"Animal feeding stuffs and raw materials for their production Determination of coccidiostats by LC-MS/MS method Robenidin hydrochloride  monensin sodium  salinomycin sodium  narasin  lasalocid sodium  halofuginon hydrobromide  semduramicin sodium  maduramicin ammonium alpha  diclazuril  nicarbazin  decoquinate  dimetridazole  JPP ÚKZÚZ, 10620.3","search_zh":"饲料及其生产原料 LC-MS/MS法测定抗球虫药含量 盐酸罗贝胍  莫能菌素钠  盐霉素钠  甲基盐霉素  拉沙洛西钠  氢溴酸常山酮  赛杜霉素钠  马度米星铵α  地克珠利  尼卡巴嗪  癸氧喹酯  二甲硝咪唑  JPP ÚKZÚZ, 10620.3","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a478c5da6cb2cdda06887269","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"20","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości niedozwolonych dodatków paszowych metodą LC-MS/MS","methodology_en":"Determination of unauthorised feed additives by LC-MS/MS method","methodology_zh":"LC-MS/MS法测定未经批准饲料添加剂含量","methodology_cs":"Stanovení obsahu nepovolených doplňkových látek metodou LC-MS/MS","parameters":[{"name":"Olachindoks","range":""},{"name":"karbadoks","range":""},{"name":"bacytracyna cynkowa","range":""},{"name":"wirginiamycyna","range":""},{"name":"tylozyna","range":""},{"name":"fosforan tylozyny","range":""}],"parameters_en":[{"name":"Olaquindox","range":""},{"name":"Carbadox","range":""},{"name":"Zinc-bacitracin","range":""},{"name":"Virginiamycin","range":""},{"name":"Tylosin","range":""},{"name":"Tylosin phosphate","range":""}],"parameters_zh":[{"name":"喹乙醇","range":""},{"name":"卡巴氧","range":""},{"name":"杆菌肽锌","range":""},{"name":"维吉尼霉素","range":""},{"name":"泰乐菌素","range":""},{"name":"磷酸泰乐菌素","range":""}],"parameters_cs":[{"name":"Olachindox","range":""},{"name":"Carbadox","range":""},{"name":"Zink-bacitracin","range":""},{"name":"Virginiamycin","range":""},{"name":"Tylosin","range":""},{"name":"Tylosin fosfát","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości niedozwolonych dodatków paszowych metodą LC-MS/MS\nZakres:\nOlachindoks\nkarbadoks\nbacytracyna cynkowa\nwirginiamycyna\ntylozyna\nfosforan tylozyny","reference":"JPP ÚKZÚZ, 10630.2","norm_bases":["JPP ÚKZÚZ, 10630.2"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości niedozwolonych dodatków paszowych metodą LC-MS/MS Olachindoks  karbadoks  bacytracyna cynkowa  wirginiamycyna  tylozyna  fosforan tylozyny  Krmiva a suroviny pro jejich výrobu Stanovení obsahu nepovolených doplňkových látek metodou LC-MS/MS Olachindox  Carbadox  Zink-bacitracin  Virginiamycin  Tylosin  Tylosin fosfát  JPP ÚKZÚZ, 10630.2 Pasze i surowce do ich produkcji Oznaczanie zawartosci niedozwolonych dodatkow paszowych metoda LC-MS/MS Olachindoks  karbadoks  bacytracyna cynkowa  wirginiamycyna  tylozyna  fosforan tylozyny  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu nepovolenych doplnkovych latek metodou LC-MS/MS Olachindox  Carbadox  Zink-bacitracin  Virginiamycin  Tylosin  Tylosin fosfat  JPP UKZUZ, 10630.2","search_en":"Animal feeding stuffs and raw materials for their production Determination of unauthorised feed additives by LC-MS/MS method Olaquindox  Carbadox  Zinc-bacitracin  Virginiamycin  Tylosin  Tylosin phosphate  JPP ÚKZÚZ, 10630.2","search_zh":"饲料及其生产原料 LC-MS/MS法测定未经批准饲料添加剂含量 喹乙醇  卡巴氧  杆菌肽锌  维吉尼霉素  泰乐菌素  磷酸泰乐菌素  JPP ÚKZÚZ, 10630.2","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cac096e5b8588a6d401eeaf6","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"21","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości aminokwasów metodą chromatografii jonowymiennej","methodology_en":"Determination of amino acids by ion exchange chromatography","methodology_zh":"离子交换色谱法测定氨基酸含量","methodology_cs":"Stanovení obsahu aminokyselin metodou iontově-výměnné chromatografie","parameters":[{"name":"Lizyna","range":""},{"name":"kwas asparaginowy","range":""},{"name":"treonina","range":""},{"name":"seryna","range":""},{"name":"kwas glutaminowy","range":""},{"name":"prolina","range":""},{"name":"glicyna","range":""},{"name":"alanina","range":""},{"name":"cystyna","range":""},{"name":"walina","range":""},{"name":"metionina","range":""},{"name":"izoleucyna","range":""},{"name":"leucyna","range":""},{"name":"tyrozyna","range":""},{"name":"fenyloalanina","range":""},{"name":"histydyna","range":""},{"name":"arginina","range":""}],"parameters_en":[{"name":"Lysine","range":""},{"name":"aspartic acid","range":""},{"name":"threonine","range":""},{"name":"serine","range":""},{"name":"glutamic acid","range":""},{"name":"proline","range":""},{"name":"glycine","range":""},{"name":"alanine","range":""},{"name":"cystine","range":""},{"name":"valine","range":""},{"name":"methionine","range":""},{"name":"isoleucine","range":""},{"name":"leucine","range":""},{"name":"tyrosine","range":""},{"name":"phenylalanine","range":""},{"name":"histidine","range":""},{"name":"arginine","range":""}],"parameters_zh":[{"name":"赖氨酸","range":""},{"name":"天冬氨酸","range":""},{"name":"苏氨酸","range":""},{"name":"丝氨酸","range":""},{"name":"谷氨酸","range":""},{"name":"脯氨酸","range":""},{"name":"甘氨酸","range":""},{"name":"丙氨酸","range":""},{"name":"胱氨酸","range":""},{"name":"缬氨酸","range":""},{"name":"蛋氨酸","range":""},{"name":"异亮氨酸","range":""},{"name":"亮氨酸","range":""},{"name":"酪氨酸","range":""},{"name":"苯丙氨酸","range":""},{"name":"组氨酸","range":""},{"name":"精氨酸","range":""}],"parameters_cs":[{"name":"Lysin","range":""},{"name":"kyselina asparagová","range":""},{"name":"threonin","range":""},{"name":"serin","range":""},{"name":"kyselina glutamová","range":""},{"name":"prolin","range":""},{"name":"glycin","range":""},{"name":"alanin","range":""},{"name":"cystin","range":""},{"name":"valin","range":""},{"name":"methionin","range":""},{"name":"isoleucin","range":""},{"name":"leucin","range":""},{"name":"tyrosin","range":""},{"name":"phenylalanin","range":""},{"name":"histidin","range":""},{"name":"arginin","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości aminokwasów metodą chromatografii jonowymiennej\nZakres:\nLizyna\nkwas asparaginowy\ntreonina\nseryna\nkwas glutaminowy\nprolina\nglicyna\nalanina\ncystyna\nwalina\nmetionina\nizoleucyna\nleucyna\ntyrozyna\nfenyloalanina\nhistydyna\narginina","reference":"JPP ÚKZÚZ, 10021.1","norm_bases":["JPP ÚKZÚZ, 10021.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości aminokwasów metodą chromatografii jonowymiennej Lizyna  kwas asparaginowy  treonina  seryna  kwas glutaminowy  prolina  glicyna  alanina  cystyna  walina  metionina  izoleucyna  leucyna  tyrozyna  fenyloalanina  histydyna  arginina  Krmiva a suroviny pro jejich výrobu Stanovení obsahu aminokyselin metodou iontově-výměnné chromatografie Lysin  kyselina asparagová  threonin  serin  kyselina glutamová  prolin  glycin  alanin  cystin  valin  methionin  isoleucin  leucin  tyrosin  phenylalanin  histidin  arginin  JPP ÚKZÚZ, 10021.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci aminokwasow metoda chromatografii jonowymiennej Lizyna  kwas asparaginowy  treonina  seryna  kwas glutaminowy  prolina  glicyna  alanina  cystyna  walina  metionina  izoleucyna  leucyna  tyrozyna  fenyloalanina  histydyna  arginina  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu aminokyselin metodou iontove-vymenne chromatografie Lysin  kyselina asparagova  threonin  serin  kyselina glutamova  prolin  glycin  alanin  cystin  valin  methionin  isoleucin  leucin  tyrosin  phenylalanin  histidin  arginin  JPP UKZUZ, 10021.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of amino acids by ion exchange chromatography Lysine  aspartic acid  threonine  serine  glutamic acid  proline  glycine  alanine  cystine  valine  methionine  isoleucine  leucine  tyrosine  phenylalanine  histidine  arginine  JPP ÚKZÚZ, 10021.1","search_zh":"饲料及其生产原料 离子交换色谱法测定氨基酸含量 赖氨酸  天冬氨酸  苏氨酸  丝氨酸  谷氨酸  脯氨酸  甘氨酸  丙氨酸  胱氨酸  缬氨酸  蛋氨酸  异亮氨酸  亮氨酸  酪氨酸  苯丙氨酸  组氨酸  精氨酸  JPP ÚKZÚZ, 10021.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0831ab4a93857de5b3d49d95","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"22","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości skrobi metodą polarymetryczną","methodology_en":"Determination of starch by polarimetric method","methodology_zh":"旋光法测定淀粉含量","methodology_cs":"Stanovení obsahu škrobu polarimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości skrobi metodą polarymetryczną","reference":"JPP ÚKZÚZ, 10083.1","norm_bases":["JPP ÚKZÚZ, 10083.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości skrobi metodą polarymetryczną Krmiva a suroviny pro jejich výrobu Stanovení obsahu škrobu polarimetricky JPP ÚKZÚZ, 10083.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci skrobi metoda polarymetryczna Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu skrobu polarimetricky JPP UKZUZ, 10083.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of starch by polarimetric method JPP ÚKZÚZ, 10083.1","search_zh":"饲料及其生产原料 旋光法测定淀粉含量 JPP ÚKZÚZ, 10083.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"87b22d2e0ac02e23e7e52ac3","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"23","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości mocznika metodą spektrofotometryczną","methodology_en":"Determination of urea by spectrophotometric method","methodology_zh":"分光光度法测定尿素含量","methodology_cs":"Stanovení obsahu močoviny spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości mocznika metodą spektrofotometryczną","reference":"JPP ÚKZÚZ, 10009.1","norm_bases":["JPP ÚKZÚZ, 10009.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości mocznika metodą spektrofotometryczną Krmiva a suroviny pro jejich výrobu Stanovení obsahu močoviny spektrofotometricky JPP ÚKZÚZ, 10009.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci mocznika metoda spektrofotometryczna Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu mocoviny spektrofotometricky JPP UKZUZ, 10009.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of urea by spectrophotometric method JPP ÚKZÚZ, 10009.1","search_zh":"饲料及其生产原料 分光光度法测定尿素含量 JPP ÚKZÚZ, 10009.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ac57579518a437969b520982","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"24","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości hydroksyanalogu metioniny metodą HPLC/UV","methodology_en":"Determination of methionine hydroxy analogue by HPLC/UV method","methodology_zh":"HPLC/UV法测定蛋氨酸羟基类似物含量","methodology_cs":"Stanovení obsahu hydroxyanalogu methioninu metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości hydroksyanalogu metioniny metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10330.1","norm_bases":["JPP ÚKZÚZ, 10330.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości hydroksyanalogu metioniny metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení obsahu hydroxyanalogu methioninu metodou HPLC/UV JPP ÚKZÚZ, 10330.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci hydroksyanalogu metioniny metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu hydroxyanalogu methioninu metodou HPLC/UV JPP UKZUZ, 10330.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of methionine hydroxy analogue by HPLC/UV method JPP ÚKZÚZ, 10330.1","search_zh":"饲料及其生产原料 HPLC/UV法测定蛋氨酸羟基类似物含量 JPP ÚKZÚZ, 10330.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"91016d22677469abeaa7f425","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"25","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości nifursolu metodą HPLC/UV","methodology_en":"Determination of nifursol by HPLC/UV method","methodology_zh":"HPLC/UV法测定尼呋索尔含量","methodology_cs":"Stanovení obsahu nifursolu metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości nifursolu metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10635.1","norm_bases":["JPP ÚKZÚZ, 10635.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości nifursolu metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení obsahu nifursolu metodou HPLC/UV JPP ÚKZÚZ, 10635.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci nifursolu metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu nifursolu metodou HPLC/UV JPP UKZUZ, 10635.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of nifursol by HPLC/UV method JPP ÚKZÚZ, 10635.1","search_zh":"饲料及其生产原料 HPLC/UV法测定尼呋索尔含量 JPP ÚKZÚZ, 10635.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9ccc021e47c4807650de83f9","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"26","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości kwasu benzoesowego metodą HPLC/UV","methodology_en":"Determination of benzoic acid by HPLC/UV method","methodology_zh":"HPLC/UV法测定苯甲酸含量","methodology_cs":"Stanovení obsahu kyseliny benzoové metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości kwasu benzoesowego metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10336.1","norm_bases":["JPP ÚKZÚZ, 10336.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości kwasu benzoesowego metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení obsahu kyseliny benzoové metodou HPLC/UV JPP ÚKZÚZ, 10336.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci kwasu benzoesowego metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu kyseliny benzoove metodou HPLC/UV JPP UKZUZ, 10336.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of benzoic acid by HPLC/UV method JPP ÚKZÚZ, 10336.1","search_zh":"饲料及其生产原料 HPLC/UV法测定苯甲酸含量 JPP ÚKZÚZ, 10336.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"38221b2e4bc31c4ce408d6dc","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"27","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości tryptofanu całkowitego i wolnego metodą HPLC/FLD","methodology_en":"Determination of total and free tryptophan by HPLC/FLD method","methodology_zh":"HPLC/FLD法测定总色氨酸和游离色氨酸含量","methodology_cs":"Stanovení obsahu celkového a volného tryptofanu metodou HPLC/FLD","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości tryptofanu całkowitego i wolnego metodą HPLC/FLD","reference":"JPP ÚKZÚZ, 10023.2","norm_bases":["JPP ÚKZÚZ, 10023.2"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości tryptofanu całkowitego i wolnego metodą HPLC/FLD Krmiva a suroviny pro jejich výrobu Stanovení obsahu celkového a volného tryptofanu metodou HPLC/FLD JPP ÚKZÚZ, 10023.2 Pasze i surowce do ich produkcji Oznaczanie zawartosci tryptofanu calkowitego i wolnego metoda HPLC/FLD Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu celkoveho a volneho tryptofanu metodou HPLC/FLD JPP UKZUZ, 10023.2","search_en":"Animal feeding stuffs and raw materials for their production Determination of total and free tryptophan by HPLC/FLD method JPP ÚKZÚZ, 10023.2","search_zh":"饲料及其生产原料 HPLC/FLD法测定总色氨酸和游离色氨酸含量 JPP ÚKZÚZ, 10023.2","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"47299f4732f50e50a5bc9380","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"29","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości dekokwinatu metodą HPLC/FLD","methodology_en":"Determination of decoquinate by HPLC/FLD method","methodology_zh":"HPLC/FLD法测定癸氧喹酯含量","methodology_cs":"Stanovení obsahu dekochinátu metodou HPLC/FLD","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości dekokwinatu metodą HPLC/FLD","reference":"JPP ÚKZÚZ, 10370.1","norm_bases":["JPP ÚKZÚZ, 10370.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości dekokwinatu metodą HPLC/FLD Krmiva a suroviny pro jejich výrobu Stanovení obsahu dekochinátu metodou HPLC/FLD JPP ÚKZÚZ, 10370.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci dekokwinatu metoda HPLC/FLD Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu dekochinatu metodou HPLC/FLD JPP UKZUZ, 10370.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of decoquinate by HPLC/FLD method JPP ÚKZÚZ, 10370.1","search_zh":"饲料及其生产原料 HPLC/FLD法测定癸氧喹酯含量 JPP ÚKZÚZ, 10370.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"860571200e40ee7727809179","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"30","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości sulfonamidów metodą LC-MS/MS","methodology_en":"Determination of sulfonamides by LC-MS/MS method","methodology_zh":"LC-MS/MS法测定磺胺类含量","methodology_cs":"Stanovení obsahu sulfonamidů metodou LC-MS/MS","parameters":[{"name":"Sulfadiazyna","range":""},{"name":"sulfametazyna","range":""},{"name":"sulfamerazyna","range":""},{"name":"sulfametoksazol","range":""}],"parameters_en":[{"name":"Sulfadiazine","range":""},{"name":"sulfametazine","range":""},{"name":"sulfamerazine","range":""},{"name":"sulfamethoxazole","range":""}],"parameters_zh":[{"name":"磺胺嘧啶","range":""},{"name":"磺胺二甲嘧啶","range":""},{"name":"磺胺甲基嘧啶","range":""},{"name":"磺胺甲噁唑","range":""}],"parameters_cs":[{"name":"Sulfadiazin","range":""},{"name":"sulfametazin","range":""},{"name":"sulfamerazin","range":""},{"name":"sulfametoxazol","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości sulfonamidów metodą LC-MS/MS\nZakres:\nSulfadiazyna\nsulfametazyna\nsulfamerazyna\nsulfametoksazol","reference":"JPP ÚKZÚZ, 10622.2","norm_bases":["JPP ÚKZÚZ, 10622.2"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości sulfonamidów metodą LC-MS/MS Sulfadiazyna  sulfametazyna  sulfamerazyna  sulfametoksazol  Krmiva a suroviny pro jejich výrobu Stanovení obsahu sulfonamidů metodou LC-MS/MS Sulfadiazin  sulfametazin  sulfamerazin  sulfametoxazol  JPP ÚKZÚZ, 10622.2 Pasze i surowce do ich produkcji Oznaczanie zawartosci sulfonamidow metoda LC-MS/MS Sulfadiazyna  sulfametazyna  sulfamerazyna  sulfametoksazol  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu sulfonamidu metodou LC-MS/MS Sulfadiazin  sulfametazin  sulfamerazin  sulfametoxazol  JPP UKZUZ, 10622.2","search_en":"Animal feeding stuffs and raw materials for their production Determination of sulfonamides by LC-MS/MS method Sulfadiazine  sulfametazine  sulfamerazine  sulfamethoxazole  JPP ÚKZÚZ, 10622.2","search_zh":"饲料及其生产原料 LC-MS/MS法测定磺胺类含量 磺胺嘧啶  磺胺二甲嘧啶  磺胺甲基嘧啶  磺胺甲噁唑  JPP ÚKZÚZ, 10622.2","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b5a536c031d49f1f14192425","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"31","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości amoksycyliny metodą LC-MS/MS","methodology_en":"Determination of amoxicilin by LC-MS/MS method","methodology_zh":"LC-MS/MS法测定阿莫西林含量","methodology_cs":"Stanovení obsahu amoxicilinu metodou LC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości amoksycyliny metodą LC-MS/MS","reference":"JPP ÚKZÚZ, 10637.1","norm_bases":["JPP ÚKZÚZ, 10637.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości amoksycyliny metodą LC-MS/MS Krmiva a suroviny pro jejich výrobu Stanovení obsahu amoxicilinu metodou LC-MS/MS JPP ÚKZÚZ, 10637.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci amoksycyliny metoda LC-MS/MS Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu amoxicilinu metodou LC-MS/MS JPP UKZUZ, 10637.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of amoxicilin by LC-MS/MS method JPP ÚKZÚZ, 10637.1","search_zh":"饲料及其生产原料 LC-MS/MS法测定阿莫西林含量 JPP ÚKZÚZ, 10637.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3e9a35e7c097b2ef8726d795","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"32","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości tiamuliny metodą LC-MS/MS","methodology_en":"Determination of tiamulin by LC-MS/MS method","methodology_zh":"LC-MS/MS法测定泰妙菌素含量","methodology_cs":"Stanovení obsahu tiamulinu metodou LC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości tiamuliny metodą LC-MS/MS","reference":"JPP ÚKZÚZ, 10638.1","norm_bases":["JPP ÚKZÚZ, 10638.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości tiamuliny metodą LC-MS/MS Krmiva a suroviny pro jejich výrobu Stanovení obsahu tiamulinu metodou LC-MS/MS JPP ÚKZÚZ, 10638.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci tiamuliny metoda LC-MS/MS Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu tiamulinu metodou LC-MS/MS JPP UKZUZ, 10638.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of tiamulin by LC-MS/MS method JPP ÚKZÚZ, 10638.1","search_zh":"饲料及其生产原料 LC-MS/MS法测定泰妙菌素含量 JPP ÚKZÚZ, 10638.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"716b1d853a6f19cb80b1568a","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"33","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości mocznika metodą LC-MS/MS","methodology_en":"Determination of urea by LC-MS/MS method","methodology_zh":"LC-MS/MS法测定尿素含量","methodology_cs":"Stanovení obsahu močoviny metodou LC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości mocznika metodą LC-MS/MS","reference":"JPP ÚKZÚZ, 10625.1","norm_bases":["JPP ÚKZÚZ, 10625.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Praga","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Praha","lab_section_zh":"ÚKZÚZ, NRL，NRL布拉格科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Praha","lab_address":"Za Opravnou 4, 150 06 Praha 5 - Motol","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości mocznika metodą LC-MS/MS Krmiva a suroviny pro jejich výrobu Stanovení obsahu močoviny metodou LC-MS/MS JPP ÚKZÚZ, 10625.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci mocznika metoda LC-MS/MS Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu mocoviny metodou LC-MS/MS JPP UKZUZ, 10625.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of urea by LC-MS/MS method JPP ÚKZÚZ, 10625.1","search_zh":"饲料及其生产原料 LC-MS/MS法测定尿素含量 JPP ÚKZÚZ, 10625.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f6c5954f03f58c39629e7a7b","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"1","test_object":"Gleby","test_object_en":"Soil","test_object_zh":"土壤","test_object_cs":"Půdy","methodology":"Oznaczanie pH metodą ISE","methodology_en":"Determination of pH by ISE method","methodology_zh":"离子选择电极法测定pH","methodology_cs":"Stanovení pH metodou ISE","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą ISE","reference":"JPP ÚKZÚZ, 30040.1","norm_bases":["JPP ÚKZÚZ, 30040.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby Oznaczanie pH metodą ISE Půdy Stanovení pH metodou ISE JPP ÚKZÚZ, 30040.1 Gleby Oznaczanie pH metoda ISE Pudy Stanoveni pH metodou ISE JPP UKZUZ, 30040.1","search_en":"Soil Determination of pH by ISE method JPP ÚKZÚZ, 30040.1","search_zh":"土壤 离子选择电极法测定pH JPP ÚKZÚZ, 30040.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"db9adb9ca31fe42385d86eff","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"2","test_object":"Gleby i osady","test_object_en":"Soil and sludge","test_object_zh":"土壤和污泥","test_object_cs":"Půdy a kaly","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES","methodology_en":"Determination of selected elements by ICP-OES method","methodology_zh":"ICP-OES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou ICP-OES","parameters":[{"name":"Fosfor (P)","range":""},{"name":"Potas (K)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Sód (Na)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Glin (Al)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Arsen (As)","range":""},{"name":"Siarka (S)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Wanad (V)","range":""}],"parameters_en":[{"name":"Phosphorus (P)","range":""},{"name":"Potassium (K)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Sulphur (S)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Vanadium (V)","range":""}],"parameters_zh":[{"name":"磷（P）","range":""},{"name":"钾（K）","range":""},{"name":"钙（Ca）","range":""},{"name":"镁（Mg）","range":""},{"name":"钠（Na）","range":""},{"name":"铜（Cu）","range":""},{"name":"锌（Zn）","range":""},{"name":"镍（Ni）","range":""},{"name":"钴（Co）","range":""},{"name":"铅（Pb）","range":""},{"name":"镉（Cd）","range":""},{"name":"铍（Be）","range":""},{"name":"铬（Cr）","range":""},{"name":"铝（Al）","range":""},{"name":"铁（Fe）","range":""},{"name":"锰（Mn）","range":""},{"name":"砷（As）","range":""},{"name":"硫（S）","range":""},{"name":"钼（Mo）","range":""},{"name":"钒（V）","range":""}],"parameters_cs":[{"name":"P","range":""},{"name":"K","range":""},{"name":"Ca","range":""},{"name":"Mg","range":""},{"name":"Na","range":""},{"name":"Cu","range":""},{"name":"Zn","range":""},{"name":"Ni","range":""},{"name":"Co","range":""},{"name":"Pb","range":""},{"name":"Cd","range":""},{"name":"Be","range":""},{"name":"Cr","range":""},{"name":"Al","range":""},{"name":"Fe","range":""},{"name":"Mn","range":""},{"name":"As","range":""},{"name":"S","range":""},{"name":"Mo","range":""},{"name":"V","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES\nZakres:\nFosfor (P)\nPotas (K)\nWapń (Ca)\nMagnez (Mg)\nSód (Na)\nMiedź (Cu)\nCynk (Zn)\nNikiel (Ni)\nKobalt (Co)\nOłów (Pb)\nKadm (Cd)\nBeryl (Be)\nChrom (Cr)\nGlin (Al)\nŻelazo (Fe)\nMangan (Mn)\nArsen (As)\nSiarka (S)\nMolibden (Mo)\nWanad (V)","reference":"JPP ÚKZÚZ, 30350.2; JPP ÚKZÚZ, 30500.2","norm_bases":["JPP ÚKZÚZ, 30350.2","JPP ÚKZÚZ, 30500.2"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby i osady Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES Fosfor (P)  Potas (K)  Wapń (Ca)  Magnez (Mg)  Sód (Na)  Miedź (Cu)  Cynk (Zn)  Nikiel (Ni)  Kobalt (Co)  Ołów (Pb)  Kadm (Cd)  Beryl (Be)  Chrom (Cr)  Glin (Al)  Żelazo (Fe)  Mangan (Mn)  Arsen (As)  Siarka (S)  Molibden (Mo)  Wanad (V)  Půdy a kaly Stanovení obsahu vybraných prvků metodou ICP-OES P  K  Ca  Mg  Na  Cu  Zn  Ni  Co  Pb  Cd  Be  Cr  Al  Fe  Mn  As  S  Mo  V  JPP ÚKZÚZ, 30350.2; JPP ÚKZÚZ, 30500.2 Gleby i osady Oznaczanie zawartosci wybranych pierwiastkow metoda ICP-OES Fosfor (P)  Potas (K)  Wapn (Ca)  Magnez (Mg)  Sod (Na)  Miedz (Cu)  Cynk (Zn)  Nikiel (Ni)  Kobalt (Co)  Olow (Pb)  Kadm (Cd)  Beryl (Be)  Chrom (Cr)  Glin (Al)  Zelazo (Fe)  Mangan (Mn)  Arsen (As)  Siarka (S)  Molibden (Mo)  Wanad (V)  Pudy a kaly Stanoveni obsahu vybranych prvku metodou ICP-OES P  K  Ca  Mg  Na  Cu  Zn  Ni  Co  Pb  Cd  Be  Cr  Al  Fe  Mn  As  S  Mo  V  JPP UKZUZ, 30350.2; JPP UKZUZ, 30500.2","search_en":"Soil and sludge Determination of selected elements by ICP-OES method Phosphorus (P)  Potassium (K)  Calcium (Ca)  Magnesium (Mg)  Sodium (Na)  Copper (Cu)  Zinc (Zn)  Nickel (Ni)  Cobalt (Co)  Lead (Pb)  Cadmium (Cd)  Beryllium (Be)  Chromium (Cr)  Aluminium (Al)  Iron (Fe)  Manganese (Mn)  Arsenic (As)  Sulphur (S)  Molybdenum (Mo)  Vanadium (V)  JPP ÚKZÚZ, 30350.2; JPP ÚKZÚZ, 30500.2","search_zh":"土壤和污泥 ICP-OES法测定选定元素含量 磷（P）  钾（K）  钙（Ca）  镁（Mg）  钠（Na）  铜（Cu）  锌（Zn）  镍（Ni）  钴（Co）  铅（Pb）  镉（Cd）  铍（Be）  铬（Cr）  铝（Al）  铁（Fe）  锰（Mn）  砷（As）  硫（S）  钼（Mo）  钒（V）  JPP ÚKZÚZ, 30350.2; JPP ÚKZÚZ, 30500.2","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d7b9d819ec3067849deed03a","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"3","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES","methodology_en":"Determination of selected elements by ICP-OES method","methodology_zh":"ICP-OES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou ICP-OES","parameters":[{"name":"Fosfor (P)","range":""},{"name":"Potas (K)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Sód (Na)","range":""},{"name":"Siarka (S)","range":""}],"parameters_en":[{"name":"Phosphorus (P)","range":""},{"name":"Potassium (K)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Sulphur (S)","range":""}],"parameters_zh":[{"name":"磷（P）","range":""},{"name":"钾（K）","range":""},{"name":"钙（Ca）","range":""},{"name":"镁（Mg）","range":""},{"name":"钠（Na）","range":""},{"name":"硫（S）","range":""}],"parameters_cs":[{"name":"P","range":""},{"name":"K","range":""},{"name":"Ca","range":""},{"name":"Mg","range":""},{"name":"Na","range":""},{"name":"S","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES\nZakres:\nFosfor (P)\nPotas (K)\nWapń (Ca)\nMagnez (Mg)\nSód (Na)\nSiarka (S)","reference":"JPP ÚKZÚZ, 40020.1; JPP ÚKZÚZ, 40032.1; JPP ÚKZÚZ, 40090.1","norm_bases":["JPP ÚKZÚZ, 40020.1","JPP ÚKZÚZ, 40032.1","JPP ÚKZÚZ, 40090.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES Fosfor (P)  Potas (K)  Wapń (Ca)  Magnez (Mg)  Sód (Na)  Siarka (S)  Rostlinný materiál Stanovení obsahu vybraných prvků metodou ICP-OES P  K  Ca  Mg  Na  S  JPP ÚKZÚZ, 40020.1; JPP ÚKZÚZ, 40032.1; JPP ÚKZÚZ, 40090.1 Material roslinny Oznaczanie zawartosci wybranych pierwiastkow metoda ICP-OES Fosfor (P)  Potas (K)  Wapn (Ca)  Magnez (Mg)  Sod (Na)  Siarka (S)  Rostlinny material Stanoveni obsahu vybranych prvku metodou ICP-OES P  K  Ca  Mg  Na  S  JPP UKZUZ, 40020.1; JPP UKZUZ, 40032.1; JPP UKZUZ, 40090.1","search_en":"Plant material Determination of selected elements by ICP-OES method Phosphorus (P)  Potassium (K)  Calcium (Ca)  Magnesium (Mg)  Sodium (Na)  Sulphur (S)  JPP ÚKZÚZ, 40020.1; JPP ÚKZÚZ, 40032.1; JPP ÚKZÚZ, 40090.1","search_zh":"植物材料 ICP-OES法测定选定元素含量 磷（P）  钾（K）  钙（Ca）  镁（Mg）  钠（Na）  硫（S）  JPP ÚKZÚZ, 40020.1; JPP ÚKZÚZ, 40032.1; JPP ÚKZÚZ, 40090.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7fd0872ecdd9e63b501c7896","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"4","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES","methodology_en":"Determination of selected elements by ICP-OES method","methodology_zh":"ICP-OES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou ICP-OES","parameters":[{"name":"Fosfor (P)","range":""},{"name":"Potas (K)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Sód (Na)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Siarka (S)","range":""}],"parameters_en":[{"name":"Phosphorus (P)","range":""},{"name":"Potassium (K)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Sulphur (S)","range":""}],"parameters_zh":[{"name":"磷（P）","range":""},{"name":"钾（K）","range":""},{"name":"钙（Ca）","range":""},{"name":"镁（Mg）","range":""},{"name":"钠（Na）","range":""},{"name":"铜（Cu）","range":""},{"name":"锌（Zn）","range":""},{"name":"铁（Fe）","range":""},{"name":"锰（Mn）","range":""},{"name":"硫（S）","range":""}],"parameters_cs":[{"name":"P","range":""},{"name":"K","range":""},{"name":"Ca","range":""},{"name":"Mg","range":""},{"name":"Na","range":""},{"name":"Cu","range":""},{"name":"Zn","range":""},{"name":"Fe","range":""},{"name":"Mn","range":""},{"name":"S","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES\nZakres:\nFosfor (P)\nPotas (K)\nWapń (Ca)\nMagnez (Mg)\nSód (Na)\nMiedź (Cu)\nCynk (Zn)\nŻelazo (Fe)\nMangan (Mn)\nSiarka (S)","reference":"JPP ÚKZÚZ, 10150.1; JPP ÚKZÚZ, 10320.1; JPP ÚKZÚZ, 10180.1","norm_bases":["JPP ÚKZÚZ, 10150.1","JPP ÚKZÚZ, 10320.1","JPP ÚKZÚZ, 10180.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES Fosfor (P)  Potas (K)  Wapń (Ca)  Magnez (Mg)  Sód (Na)  Miedź (Cu)  Cynk (Zn)  Żelazo (Fe)  Mangan (Mn)  Siarka (S)  Krmiva a suroviny pro jejich výrobu Stanovení obsahu vybraných prvků metodou ICP-OES P  K  Ca  Mg  Na  Cu  Zn  Fe  Mn  S  JPP ÚKZÚZ, 10150.1; JPP ÚKZÚZ, 10320.1; JPP ÚKZÚZ, 10180.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wybranych pierwiastkow metoda ICP-OES Fosfor (P)  Potas (K)  Wapn (Ca)  Magnez (Mg)  Sod (Na)  Miedz (Cu)  Cynk (Zn)  Zelazo (Fe)  Mangan (Mn)  Siarka (S)  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vybranych prvku metodou ICP-OES P  K  Ca  Mg  Na  Cu  Zn  Fe  Mn  S  JPP UKZUZ, 10150.1; JPP UKZUZ, 10320.1; JPP UKZUZ, 10180.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of selected elements by ICP-OES method Phosphorus (P)  Potassium (K)  Calcium (Ca)  Magnesium (Mg)  Sodium (Na)  Copper (Cu)  Zinc (Zn)  Iron (Fe)  Manganese (Mn)  Sulphur (S)  JPP ÚKZÚZ, 10150.1; JPP ÚKZÚZ, 10320.1; JPP ÚKZÚZ, 10180.1","search_zh":"饲料及其生产原料 ICP-OES法测定选定元素含量 磷（P）  钾（K）  钙（Ca）  镁（Mg）  钠（Na）  铜（Cu）  锌（Zn）  铁（Fe）  锰（Mn）  硫（S）  JPP ÚKZÚZ, 10150.1; JPP ÚKZÚZ, 10320.1; JPP ÚKZÚZ, 10180.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"73b475bc2c516b90b585bd3a","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"5","test_object":"Gleby","test_object_en":"Soil","test_object_zh":"土壤","test_object_cs":"Půdy","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES","methodology_en":"Determination of selected elements by ICP-OES method","methodology_zh":"ICP-OES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou ICP-OES","parameters":[{"name":"Glin (Al)","range":""},{"name":"Bor (B)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Siarka (S)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Aluminium (Al)","range":""},{"name":"Boron (B)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Sulphur (S)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"铝（Al）","range":""},{"name":"硼（B）","range":""},{"name":"钙（Ca）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"磷（P）","range":""},{"name":"硫（S）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"B","range":""},{"name":"Ca","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"P","range":""},{"name":"S","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES\nZakres:\nGlin (Al)\nBor (B)\nWapń (Ca)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nFosfor (P)\nSiarka (S)\nCynk (Zn)","reference":"JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30074.1","norm_bases":["JPP ÚKZÚZ, 30068.1","JPP ÚKZÚZ, 30074.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES Glin (Al)  Bor (B)  Wapń (Ca)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Fosfor (P)  Siarka (S)  Cynk (Zn)  Půdy Stanovení obsahu vybraných prvků metodou ICP-OES Al  B  Ca  Cu  Fe  K  Mg  Mn  P  S  Zn  JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30074.1 Gleby Oznaczanie zawartosci wybranych pierwiastkow metoda ICP-OES Glin (Al)  Bor (B)  Wapn (Ca)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Fosfor (P)  Siarka (S)  Cynk (Zn)  Pudy Stanoveni obsahu vybranych prvku metodou ICP-OES Al  B  Ca  Cu  Fe  K  Mg  Mn  P  S  Zn  JPP UKZUZ, 30068.1; JPP UKZUZ, 30074.1","search_en":"Soil Determination of selected elements by ICP-OES method Aluminium (Al)  Boron (B)  Calcium (Ca)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Phosphorus (P)  Sulphur (S)  Zinc (Zn)  JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30074.1","search_zh":"土壤 ICP-OES法测定选定元素含量 铝（Al）  硼（B）  钙（Ca）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  磷（P）  硫（S）  锌（Zn）  JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30074.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5a26cea916fd5f6f1b5b8b9f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"6","test_object":"Gleby","test_object_en":"Soil","test_object_zh":"土壤","test_object_cs":"Půdy","methodology":"Oznaczanie zawartości fosforu metodą spektrofotometryczną","methodology_en":"Determination of phosphorus by spectrophotometric method","methodology_zh":"分光光度法测定磷含量","methodology_cs":"Stanovení obsahu fosforu spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości fosforu metodą spektrofotometryczną","reference":"JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30072.1","norm_bases":["JPP ÚKZÚZ, 30068.1","JPP ÚKZÚZ, 30072.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby Oznaczanie zawartości fosforu metodą spektrofotometryczną Půdy Stanovení obsahu fosforu spektrofotometricky JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30072.1 Gleby Oznaczanie zawartosci fosforu metoda spektrofotometryczna Pudy Stanoveni obsahu fosforu spektrofotometricky JPP UKZUZ, 30068.1; JPP UKZUZ, 30072.1","search_en":"Soil Determination of phosphorus by spectrophotometric method JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30072.1","search_zh":"土壤 分光光度法测定磷含量 JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30072.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8bf6320d7b07183d3a373d47","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"7","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP ÚKZÚZ, 10001.1","norm_bases":["JPP ÚKZÚZ, 10001.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Krmiva a suroviny pro jejich výrobu Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP ÚKZÚZ, 10001.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 10001.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of moisture by gravimetric method and calculation of dry matter JPP ÚKZÚZ, 10001.1","search_zh":"饲料及其生产原料 重量法测定水分含量并计算干物质 JPP ÚKZÚZ, 10001.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fa0c9d81acedbf6fdd60941a","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"8","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP ÚKZÚZ, 40010.1","norm_bases":["JPP ÚKZÚZ, 40010.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Rostlinný materiál Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP ÚKZÚZ, 40010.1 Material roslinny Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Rostlinny material Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 40010.1","search_en":"Plant material Determination of moisture by gravimetric method and calculation of dry matter JPP ÚKZÚZ, 40010.1","search_zh":"植物材料 重量法测定水分含量并计算干物质 JPP ÚKZÚZ, 40010.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cb4e322896b6fdf8b4bc0eb7","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"9","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP ÚKZÚZ, 30020.1","norm_bases":["JPP ÚKZÚZ, 30020.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Půdy, kaly, sedimenty Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP ÚKZÚZ, 30020.1 Gleby, osady, osady denne Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Pudy, kaly, sedimenty Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 30020.1","search_en":"Soil, sludge, sediments Determination of moisture by gravimetric method and calculation of dry matter JPP ÚKZÚZ, 30020.1","search_zh":"土壤、污泥、沉积物 重量法测定水分含量并计算干物质 JPP ÚKZÚZ, 30020.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d642505865dc05982742f2bb","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"10","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP ÚKZÚZ, 50010.1","norm_bases":["JPP ÚKZÚZ, 50010.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Rostlinný materiál Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP ÚKZÚZ, 50010.1 Material roslinny Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Rostlinny material Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 50010.1","search_en":"Plant material Determination of moisture by gravimetric method and calculation of dry matter JPP ÚKZÚZ, 50010.1","search_zh":"植物材料 重量法测定水分含量并计算干物质 JPP ÚKZÚZ, 50010.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"18ccd9e3a4e18e38a3bc1534","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"11","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości Hg na aparacie AMA","methodology_en":"Determination of mercury using AMA instrument","methodology_zh":"AMA仪器测定汞含量","methodology_cs":"Stanovení obsahu Hg na přístroji AMA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości Hg na aparacie AMA","reference":"JPP ÚKZÚZ, 10420.1","norm_bases":["JPP ÚKZÚZ, 10420.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości Hg na aparacie AMA Krmiva a suroviny pro jejich výrobu Stanovení obsahu Hg na přístroji AMA JPP ÚKZÚZ, 10420.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci Hg na aparacie AMA Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu Hg na pristroji AMA JPP UKZUZ, 10420.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of mercury using AMA instrument JPP ÚKZÚZ, 10420.1","search_zh":"饲料及其生产原料 AMA仪器测定汞含量 JPP ÚKZÚZ, 10420.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"91dc7a90c8f81631cf3a5aa1","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"12","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości Hg na aparacie AMA","methodology_en":"Determination of mercury using AMA instrument","methodology_zh":"AMA仪器测定汞含量","methodology_cs":"Stanovení obsahu Hg na přístroji AMA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości Hg na aparacie AMA","reference":"JPP ÚKZÚZ, 30460.1","norm_bases":["JPP ÚKZÚZ, 30460.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie zawartości Hg na aparacie AMA Půdy, kaly, sedimenty Stanovení obsahu Hg na přístroji AMA JPP ÚKZÚZ, 30460.1 Gleby, osady, osady denne Oznaczanie zawartosci Hg na aparacie AMA Pudy, kaly, sedimenty Stanoveni obsahu Hg na pristroji AMA JPP UKZUZ, 30460.1","search_en":"Soil, sludge, sediments Determination of mercury using AMA instrument JPP ÚKZÚZ, 30460.1","search_zh":"土壤、污泥、沉积物 AMA仪器测定汞含量 JPP ÚKZÚZ, 30460.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a4843dd35eebbbf2ff88f86e","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"13","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości Hg na aparacie AMA","methodology_en":"Determination of mercury using AMA instrument","methodology_zh":"AMA仪器测定汞含量","methodology_cs":"Stanovení obsahu Hg na přístroji AMA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości Hg na aparacie AMA","reference":"JPP ÚKZÚZ, 40190.1","norm_bases":["JPP ÚKZÚZ, 40190.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości Hg na aparacie AMA Rostlinný materiál Stanovení obsahu Hg na přístroji AMA JPP ÚKZÚZ, 40190.1 Material roslinny Oznaczanie zawartosci Hg na aparacie AMA Rostlinny material Stanoveni obsahu Hg na pristroji AMA JPP UKZUZ, 40190.1","search_en":"Plant material Determination of mercury using AMA instrument JPP ÚKZÚZ, 40190.1","search_zh":"植物材料 AMA仪器测定汞含量 JPP ÚKZÚZ, 40190.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0f569a0b3d03559a1baa687e","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"14","test_object":"Pasze i surowce do ich produkcji, materiał roślinny","test_object_en":"Animal feeding stuffs and raw materials for their production, plant material","test_object_zh":"饲料及其生产原料、植物材料","test_object_cs":"Krmiva a suroviny pro jejich výrobu, rostlinný materiál","methodology":"Oznaczanie zawartości azotu miareczkowo i substancji azotowych obliczeniowo z wyników pomiarów","methodology_en":"Determination of the content of nitrogen by titrimetric method and nitrogenous substances by calculation from measured values","methodology_zh":"滴定法测定氮含量并由测量值计算含氮物质","methodology_cs":"Stanovení obsahu dusíku titračně a dusíkatých látek výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu miareczkowo i substancji azotowych obliczeniowo z wyników pomiarów","reference":"JPP ÚKZÚZ, 10014.1","norm_bases":["JPP ÚKZÚZ, 10014.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji, materiał roślinny Oznaczanie zawartości azotu miareczkowo i substancji azotowych obliczeniowo z wyników pomiarów Krmiva a suroviny pro jejich výrobu, rostlinný materiál Stanovení obsahu dusíku titračně a dusíkatých látek výpočtem z naměřených hodnot JPP ÚKZÚZ, 10014.1 Pasze i surowce do ich produkcji, material roslinny Oznaczanie zawartosci azotu miareczkowo i substancji azotowych obliczeniowo z wynikow pomiarow Krmiva a suroviny pro jejich vyrobu, rostlinny material Stanoveni obsahu dusiku titracne a dusikatych latek vypoctem z namerenych hodnot JPP UKZUZ, 10014.1","search_en":"Animal feeding stuffs and raw materials for their production, plant material Determination of the content of nitrogen by titrimetric method and nitrogenous substances by calculation from measured values JPP ÚKZÚZ, 10014.1","search_zh":"饲料及其生产原料、植物材料 滴定法测定氮含量并由测量值计算含氮物质 JPP ÚKZÚZ, 10014.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3c20bb8244f3d7d7309a42a1","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"15","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości azotu miareczkowo","methodology_en":"Determination of nitrogen by titrimetric method","methodology_zh":"滴定法测定氮含量","methodology_cs":"Stanovení obsahu dusíku titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu miareczkowo","reference":"JPP ÚKZÚZ, 40020.1; JPP ÚKZÚZ, 40053.1","norm_bases":["JPP ÚKZÚZ, 40020.1","JPP ÚKZÚZ, 40053.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości azotu miareczkowo Rostlinný materiál Stanovení obsahu dusíku titračně JPP ÚKZÚZ, 40020.1; JPP ÚKZÚZ, 40053.1 Material roslinny Oznaczanie zawartosci azotu miareczkowo Rostlinny material Stanoveni obsahu dusiku titracne JPP UKZUZ, 40020.1; JPP UKZUZ, 40053.1","search_en":"Plant material Determination of nitrogen by titrimetric method JPP ÚKZÚZ, 40020.1; JPP ÚKZÚZ, 40053.1","search_zh":"植物材料 滴定法测定氮含量 JPP ÚKZÚZ, 40020.1; JPP ÚKZÚZ, 40053.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"26565b07f189afc75f3fcda6","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"16","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości azotu miareczkowo","methodology_en":"Determination of nitrogen by titrimetric method","methodology_zh":"滴定法测定氮含量","methodology_cs":"Stanovení obsahu dusíku titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu miareczkowo","reference":"JPP ÚKZÚZ, 50015.1","norm_bases":["JPP ÚKZÚZ, 50015.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości azotu miareczkowo Rostlinný materiál Stanovení obsahu dusíku titračně JPP ÚKZÚZ, 50015.1 Material roslinny Oznaczanie zawartosci azotu miareczkowo Rostlinny material Stanoveni obsahu dusiku titracne JPP UKZUZ, 50015.1","search_en":"Plant material Determination of nitrogen by titrimetric method JPP ÚKZÚZ, 50015.1","search_zh":"植物材料 滴定法测定氮含量 JPP ÚKZÚZ, 50015.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7569a077760470ce4234cd1e","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"17","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości tłuszczu (oleju) metodą wagową","methodology_en":"Determination of fat (oil) by gravimetric method","methodology_zh":"重量法测定脂肪（油）含量","methodology_cs":"Stanovení obsahu tuku (oleje) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości tłuszczu (oleju) metodą wagową","reference":"JPP ÚKZÚZ, 10058.1","norm_bases":["JPP ÚKZÚZ, 10058.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości tłuszczu (oleju) metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu tuku (oleje) gravimetricky JPP ÚKZÚZ, 10058.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci tluszczu (oleju) metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu tuku (oleje) gravimetricky JPP UKZUZ, 10058.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of fat (oil) by gravimetric method JPP ÚKZÚZ, 10058.1","search_zh":"饲料及其生产原料 重量法测定脂肪（油）含量 JPP ÚKZÚZ, 10058.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cf2585a706f358a38b0b272b","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"18","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości tłuszczu (oleju) metodą wagową","methodology_en":"Determination of fat (oil) by gravimetric method","methodology_zh":"重量法测定脂肪（油）含量","methodology_cs":"Stanovení obsahu tuku (oleje) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości tłuszczu (oleju) metodą wagową","reference":"JPP ÚKZÚZ, 50078.1","norm_bases":["JPP ÚKZÚZ, 50078.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości tłuszczu (oleju) metodą wagową Rostlinný materiál Stanovení obsahu tuku (oleje) gravimetricky JPP ÚKZÚZ, 50078.1 Material roslinny Oznaczanie zawartosci tluszczu (oleju) metoda wagowa Rostlinny material Stanoveni obsahu tuku (oleje) gravimetricky JPP UKZUZ, 50078.1","search_en":"Plant material Determination of fat (oil) by gravimetric method JPP ÚKZÚZ, 50078.1","search_zh":"植物材料 重量法测定脂肪（油）含量 JPP ÚKZÚZ, 50078.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2e00413134bb86e0869f9907","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"19","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości włókna metodą wagową","methodology_en":"Determination of fibre by gravimetric method","methodology_zh":"重量法测定纤维含量","methodology_cs":"Stanovení obsahu vlákniny gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości włókna metodą wagową","reference":"JPP ÚKZÚZ, 10068.1","norm_bases":["JPP ÚKZÚZ, 10068.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości włókna metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu vlákniny gravimetricky JPP ÚKZÚZ, 10068.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wlokna metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vlakniny gravimetricky JPP UKZUZ, 10068.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of fibre by gravimetric method JPP ÚKZÚZ, 10068.1","search_zh":"饲料及其生产原料 重量法测定纤维含量 JPP ÚKZÚZ, 10068.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ed31665deea03a6f47121fab","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"20","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości włókna kwaśnego detergentowego i neutralnego detergentowego (ADF, NDF) metodą wagową","methodology_en":"Determination of acid detergent and neutral detergent fibre (ADF, NDF) by gravimetric method","methodology_zh":"重量法测定酸性洗涤纤维和中性洗涤纤维（ADF、NDF）含量","methodology_cs":"Stanovení obsahu acidodetergentní a neutrálně detergentní vlákniny (ADV, NDV) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości włókna kwaśnego detergentowego i neutralnego detergentowego (ADF, NDF) metodą wagową","reference":"JPP ÚKZÚZ, 10070.1; JPP ÚKZÚZ, 10080.1","norm_bases":["JPP ÚKZÚZ, 10070.1","JPP ÚKZÚZ, 10080.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości włókna kwaśnego detergentowego i neutralnego detergentowego (ADF, NDF) metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu acidodetergentní a neutrálně detergentní vlákniny (ADV, NDV) gravimetricky JPP ÚKZÚZ, 10070.1; JPP ÚKZÚZ, 10080.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wlokna kwasnego detergentowego i neutralnego detergentowego (ADF, NDF) metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu acidodetergentni a neutralne detergentni vlakniny (ADV, NDV) gravimetricky JPP UKZUZ, 10070.1; JPP UKZUZ, 10080.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of acid detergent and neutral detergent fibre (ADF, NDF) by gravimetric method JPP ÚKZÚZ, 10070.1; JPP ÚKZÚZ, 10080.1","search_zh":"饲料及其生产原料 重量法测定酸性洗涤纤维和中性洗涤纤维（ADF、NDF）含量 JPP ÚKZÚZ, 10070.1; JPP ÚKZÚZ, 10080.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a9cc4a6d7daccf48058c0f81","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"21","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości skrobi metodą polarymetryczną","methodology_en":"Determination of starch by polarimetric method","methodology_zh":"旋光法测定淀粉含量","methodology_cs":"Stanovení obsahu škrobu polarimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości skrobi metodą polarymetryczną","reference":"JPP ÚKZÚZ, 10083.1","norm_bases":["JPP ÚKZÚZ, 10083.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości skrobi metodą polarymetryczną Krmiva a suroviny pro jejich výrobu Stanovení obsahu škrobu polarimetricky JPP ÚKZÚZ, 10083.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci skrobi metoda polarymetryczna Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu skrobu polarimetricky JPP UKZUZ, 10083.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of starch by polarimetric method JPP ÚKZÚZ, 10083.1","search_zh":"饲料及其生产原料 旋光法测定淀粉含量 JPP ÚKZÚZ, 10083.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0152e93110be8823f4412122","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"22","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości skrobi metodą polarymetryczną","methodology_en":"Determination of starch by polarimetric method","methodology_zh":"旋光法测定淀粉含量","methodology_cs":"Stanovení obsahu škrobu polarimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości skrobi metodą polarymetryczną","reference":"JPP ÚKZÚZ, 50030.1","norm_bases":["JPP ÚKZÚZ, 50030.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości skrobi metodą polarymetryczną Rostlinný materiál Stanovení obsahu škrobu polarimetricky JPP ÚKZÚZ, 50030.1 Material roslinny Oznaczanie zawartosci skrobi metoda polarymetryczna Rostlinny material Stanoveni obsahu skrobu polarimetricky JPP UKZUZ, 50030.1","search_en":"Plant material Determination of starch by polarimetric method JPP ÚKZÚZ, 50030.1","search_zh":"植物材料 旋光法测定淀粉含量 JPP ÚKZÚZ, 50030.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"918e1bb87f241b9221b2c66d","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"23","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości cukrów miareczkowo","methodology_en":"Determination of sugars by titrimetric method","methodology_zh":"滴定法测定糖含量","methodology_cs":"Stanovení obsahu cukrů titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości cukrów miareczkowo","reference":"JPP ÚKZÚZ, 10084.1","norm_bases":["JPP ÚKZÚZ, 10084.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości cukrów miareczkowo Krmiva a suroviny pro jejich výrobu Stanovení obsahu cukrů titračně JPP ÚKZÚZ, 10084.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci cukrow miareczkowo Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu cukru titracne JPP UKZUZ, 10084.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of sugars by titrimetric method JPP ÚKZÚZ, 10084.1","search_zh":"饲料及其生产原料 滴定法测定糖含量 JPP ÚKZÚZ, 10084.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d7bd38b82c6f2afb453b212b","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"24","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości popiołu (strata prażenia) metodą wagową","methodology_en":"Determination of ash (loss on ignition) by gravimetric method","methodology_zh":"重量法测定灰分（灼烧减量）含量","methodology_cs":"Stanovení obsahu popele (ztráta žíháním) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości popiołu (strata prażenia) metodą wagową","reference":"JPP ÚKZÚZ, 10004.1","norm_bases":["JPP ÚKZÚZ, 10004.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości popiołu (strata prażenia) metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu popele (ztráta žíháním) gravimetricky JPP ÚKZÚZ, 10004.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci popiolu (strata prazenia) metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu popele (ztrata zihanim) gravimetricky JPP UKZUZ, 10004.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of ash (loss on ignition) by gravimetric method JPP ÚKZÚZ, 10004.1","search_zh":"饲料及其生产原料 重量法测定灰分（灼烧减量）含量 JPP ÚKZÚZ, 10004.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"878bf4932d637689e22ab60e","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"25","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości popiołu nierozpuszczalnego w kwasie solnym metodą wagową","methodology_en":"Determination of ash which is insoluble in hydrochloric acid by gravimetric method","methodology_zh":"重量法测定盐酸不溶性灰分含量","methodology_cs":"Stanovení obsahu nerozpustného podílu popela v kyselině chlorovodíkové gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości popiołu nierozpuszczalnego w kwasie solnym metodą wagową","reference":"JPP ÚKZÚZ, 10005.1","norm_bases":["JPP ÚKZÚZ, 10005.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości popiołu nierozpuszczalnego w kwasie solnym metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu nerozpustného podílu popela v kyselině chlorovodíkové gravimetricky JPP ÚKZÚZ, 10005.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci popiolu nierozpuszczalnego w kwasie solnym metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu nerozpustneho podilu popela v kyseline chlorovodikove gravimetricky JPP UKZUZ, 10005.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of ash which is insoluble in hydrochloric acid by gravimetric method JPP ÚKZÚZ, 10005.1","search_zh":"饲料及其生产原料 重量法测定盐酸不溶性灰分含量 JPP ÚKZÚZ, 10005.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6616962533de1a776d115758","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"26","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości chlorków rozpuszczalnych w wodzie jako chlorek sodu miareczkowo","methodology_en":"Determination of water-soluble chlorides as sodium chloride by titrimetric method","methodology_zh":"滴定法测定以氯化钠计的水溶性氯化物","methodology_cs":"Stanovení obsahu ve vodě rozpustných chloridů jako chlorid sodný titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości chlorków rozpuszczalnych w wodzie jako chlorek sodu miareczkowo","reference":"JPP ÚKZÚZ, 10131.1","norm_bases":["JPP ÚKZÚZ, 10131.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości chlorków rozpuszczalnych w wodzie jako chlorek sodu miareczkowo Krmiva a suroviny pro jejich výrobu Stanovení obsahu ve vodě rozpustných chloridů jako chlorid sodný titračně JPP ÚKZÚZ, 10131.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci chlorkow rozpuszczalnych w wodzie jako chlorek sodu miareczkowo Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu ve vode rozpustnych chloridu jako chlorid sodny titracne JPP UKZUZ, 10131.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of water-soluble chlorides as sodium chloride by titrimetric method JPP ÚKZÚZ, 10131.1","search_zh":"饲料及其生产原料 滴定法测定以氯化钠计的水溶性氯化物 JPP ÚKZÚZ, 10131.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"79a19ed0666dc5f6ca462ee8","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"27","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości witaminy A, E metodą HPLC/DAD, FLD","methodology_en":"Determination of vitamin A, E by HPLC/DAD, FLD method","methodology_zh":"HPLC/DAD、FLD法测定维生素A、E含量","methodology_cs":"Stanovení obsahu vitamínu A, E metodou HPLC/DAD, FLD","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości witaminy A, E metodą HPLC/DAD, FLD","reference":"JPP ÚKZÚZ, 10381.1","norm_bases":["JPP ÚKZÚZ, 10381.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości witaminy A, E metodą HPLC/DAD, FLD Krmiva a suroviny pro jejich výrobu Stanovení obsahu vitamínu A, E metodou HPLC/DAD, FLD JPP ÚKZÚZ, 10381.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci witaminy A, E metoda HPLC/DAD, FLD Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vitaminu A, E metodou HPLC/DAD, FLD JPP UKZUZ, 10381.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of vitamin A, E by HPLC/DAD, FLD method JPP ÚKZÚZ, 10381.1","search_zh":"饲料及其生产原料 HPLC/DAD、FLD法测定维生素A、E含量 JPP ÚKZÚZ, 10381.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"94577cfc99826be647f0e278","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"28","test_object":"Zboża","test_object_en":"Cereals","test_object_zh":"谷物","test_object_cs":"Obiloviny","methodology":"Oznaczanie liczby opadania metodą chronometryczną","methodology_en":"Determination of the Falling number by chronometric method","methodology_zh":"计时法测定降落数值","methodology_cs":"Stanovení čísla poklesu chronometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby opadania metodą chronometryczną","reference":"JPP ÚKZÚZ, 50140.1","norm_bases":["JPP ÚKZÚZ, 50140.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zboża Oznaczanie liczby opadania metodą chronometryczną Obiloviny Stanovení čísla poklesu chronometricky JPP ÚKZÚZ, 50140.1 Zboza Oznaczanie liczby opadania metoda chronometryczna Obiloviny Stanoveni cisla poklesu chronometricky JPP UKZUZ, 50140.1","search_en":"Cereals Determination of the Falling number by chronometric method JPP ÚKZÚZ, 50140.1","search_zh":"谷物 计时法测定降落数值 JPP ÚKZÚZ, 50140.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8fc3050c421cd418c468b5f4","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"29","test_object":"Zboża","test_object_en":"Cereals","test_object_zh":"谷物","test_object_cs":"Obiloviny","methodology":"Wskaźnik sedymentacji – test Zeleny'ego","methodology_en":"Sedimentation index – Zeleny test","methodology_zh":"沉降指数——Zeleny试验","methodology_cs":"Sedimentační index – Zelenyho test","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wskaźnik sedymentacji – test Zeleny'ego","reference":"JPP ÚKZÚZ, 50150.1","norm_bases":["JPP ÚKZÚZ, 50150.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zboża Wskaźnik sedymentacji – test Zeleny'ego Obiloviny Sedimentační index – Zelenyho test JPP ÚKZÚZ, 50150.1 Zboza Wskaznik sedymentacji – test Zeleny'ego Obiloviny Sedimentacni index – Zelenyho test JPP UKZUZ, 50150.1","search_en":"Cereals Sedimentation index – Zeleny test JPP ÚKZÚZ, 50150.1","search_zh":"谷物 沉降指数——Zeleny试验 JPP ÚKZÚZ, 50150.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4126917893df91fa12a27bb3","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"30","test_object":"Zboża","test_object_en":"Cereals","test_object_zh":"谷物","test_object_cs":"Obiloviny","methodology":"Farinograficzne oznaczanie wodochłonności","methodology_en":"Determination of water absorption using farinograph","methodology_zh":"粉质仪测定吸水率","methodology_cs":"Farinografické stanovení vaznosti vody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Farinograficzne oznaczanie wodochłonności","reference":"JPP ÚKZÚZ, 50160.1","norm_bases":["JPP ÚKZÚZ, 50160.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zboża Farinograficzne oznaczanie wodochłonności Obiloviny Farinografické stanovení vaznosti vody JPP ÚKZÚZ, 50160.1 Zboza Farinograficzne oznaczanie wodochlonnosci Obiloviny Farinograficke stanoveni vaznosti vody JPP UKZUZ, 50160.1","search_en":"Cereals Determination of water absorption using farinograph JPP ÚKZÚZ, 50160.1","search_zh":"谷物 粉质仪测定吸水率 JPP ÚKZÚZ, 50160.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"be2bbbacb2efd2c339705bda","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"31","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości kwasów tłuszczowych metodą GC/FID","methodology_en":"Determination of fatty acids by GC/FID method","methodology_zh":"GC/FID法测定脂肪酸含量","methodology_cs":"Stanovení obsahu mastných kyselin metodou GC/FID","parameters":[{"name":"Kwas arachidowy","range":""},{"name":"behenowy","range":""},{"name":"eikozenowy","range":""},{"name":"erukowy","range":""},{"name":"laurynowy","range":""},{"name":"lignocerynowy","range":""},{"name":"linolenowy","range":""},{"name":"linolowy","range":""},{"name":"mirystynowy","range":""},{"name":"oleinowy","range":""},{"name":"palmitynowy","range":""},{"name":"stearynowy","range":""}],"parameters_en":[{"name":"Arachic acid","range":""},{"name":"behenic acid","range":""},{"name":"eicosenoic acid","range":""},{"name":"erucic acid","range":""},{"name":"lauric acid","range":""},{"name":"lignoceric acid","range":""},{"name":"linolenic acid","range":""},{"name":"linolic acid","range":""},{"name":"myristic acid","range":""},{"name":"oleic acid","range":""},{"name":"palmitic acid","range":""},{"name":"stearic acid","range":""}],"parameters_zh":[{"name":"花生酸","range":""},{"name":"山嵛酸","range":""},{"name":"二十碳烯酸","range":""},{"name":"芥酸","range":""},{"name":"月桂酸","range":""},{"name":"木蜡酸","range":""},{"name":"亚麻酸","range":""},{"name":"亚油酸","range":""},{"name":"肉豆蔻酸","range":""},{"name":"油酸","range":""},{"name":"棕榈酸","range":""},{"name":"硬脂酸","range":""}],"parameters_cs":[{"name":"Kyselina arachová","range":""},{"name":"behenová","range":""},{"name":"eikosenová","range":""},{"name":"eruková","range":""},{"name":"laurová","range":""},{"name":"lignocerová","range":""},{"name":"linolenová","range":""},{"name":"linolová","range":""},{"name":"myristová","range":""},{"name":"olejová","range":""},{"name":"palmitová","range":""},{"name":"stearová","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości kwasów tłuszczowych metodą GC/FID\nZakres:\nKwas arachidowy\nbehenowy\neikozenowy\nerukowy\nlaurynowy\nlignocerynowy\nlinolenowy\nlinolowy\nmirystynowy\noleinowy\npalmitynowy\nstearynowy","reference":"JPP ÚKZÚZ, 50100.1","norm_bases":["JPP ÚKZÚZ, 50100.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości kwasów tłuszczowych metodą GC/FID Kwas arachidowy  behenowy  eikozenowy  erukowy  laurynowy  lignocerynowy  linolenowy  linolowy  mirystynowy  oleinowy  palmitynowy  stearynowy  Rostlinný materiál Stanovení obsahu mastných kyselin metodou GC/FID Kyselina arachová  behenová  eikosenová  eruková  laurová  lignocerová  linolenová  linolová  myristová  olejová  palmitová  stearová  JPP ÚKZÚZ, 50100.1 Material roslinny Oznaczanie zawartosci kwasow tluszczowych metoda GC/FID Kwas arachidowy  behenowy  eikozenowy  erukowy  laurynowy  lignocerynowy  linolenowy  linolowy  mirystynowy  oleinowy  palmitynowy  stearynowy  Rostlinny material Stanoveni obsahu mastnych kyselin metodou GC/FID Kyselina arachova  behenova  eikosenova  erukova  laurova  lignocerova  linolenova  linolova  myristova  olejova  palmitova  stearova  JPP UKZUZ, 50100.1","search_en":"Plant material Determination of fatty acids by GC/FID method Arachic acid  behenic acid  eicosenoic acid  erucic acid  lauric acid  lignoceric acid  linolenic acid  linolic acid  myristic acid  oleic acid  palmitic acid  stearic acid  JPP ÚKZÚZ, 50100.1","search_zh":"植物材料 GC/FID法测定脂肪酸含量 花生酸  山嵛酸  二十碳烯酸  芥酸  月桂酸  木蜡酸  亚麻酸  亚油酸  肉豆蔻酸  油酸  棕榈酸  硬脂酸  JPP ÚKZÚZ, 50100.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3dbd1ae8fa61a639d026c7ac","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"32","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości glukozynolanów metodą HPLC/DAD","methodology_en":"Determination of glucosinolates by HPLC/DAD method","methodology_zh":"HPLC/DAD法测定硫代葡萄糖苷含量","methodology_cs":"Stanovení obsahu glukosinolátů metodou HPLC/DAD","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości glukozynolanów metodą HPLC/DAD","reference":"JPP ÚKZÚZ, 50110.1","norm_bases":["JPP ÚKZÚZ, 50110.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości glukozynolanów metodą HPLC/DAD Rostlinný materiál Stanovení obsahu glukosinolátů metodou HPLC/DAD JPP ÚKZÚZ, 50110.1 Material roslinny Oznaczanie zawartosci glukozynolanow metoda HPLC/DAD Rostlinny material Stanoveni obsahu glukosinolatu metodou HPLC/DAD JPP UKZUZ, 50110.1","search_en":"Plant material Determination of glucosinolates by HPLC/DAD method JPP ÚKZÚZ, 50110.1","search_zh":"植物材料 HPLC/DAD法测定硫代葡萄糖苷含量 JPP ÚKZÚZ, 50110.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":82,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a44a8c699c47de5b517e2a55","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"33","test_object":"Rośliny oleiste, rośliny strączkowe","test_object_en":"Oil plants, legumes","test_object_zh":"油料作物、豆类","test_object_cs":"Olejniny, luštěniny","methodology":"Oznaczanie wybranych parametrów metodą NIRS","methodology_en":"Determination of selected parameters by NIRS method","methodology_zh":"NIRS法测定选定参数","methodology_cs":"Stanovení vybraných parametrů metodou NIRS","parameters":[{"name":"Tłuszcz","range":""},{"name":"olej","range":""},{"name":"sucha masa","range":""},{"name":"substancje azotowe","range":""}],"parameters_en":[{"name":"Fat","range":""},{"name":"oil","range":""},{"name":"dry matter","range":""},{"name":"nitrogenous substances","range":""}],"parameters_zh":[{"name":"脂肪","range":""},{"name":"油","range":""},{"name":"干物质","range":""},{"name":"含氮物质","range":""}],"parameters_cs":[{"name":"Tuk","range":""},{"name":"olej","range":""},{"name":"sušina","range":""},{"name":"dusíkaté látky","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych parametrów metodą NIRS\nZakres:\nTłuszcz\nolej\nsucha masa\nsubstancje azotowe","reference":"JPP ÚKZÚZ, 50050.1","norm_bases":["JPP ÚKZÚZ, 50050.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rośliny oleiste, rośliny strączkowe Oznaczanie wybranych parametrów metodą NIRS Tłuszcz  olej  sucha masa  substancje azotowe  Olejniny, luštěniny Stanovení vybraných parametrů metodou NIRS Tuk  olej  sušina  dusíkaté látky  JPP ÚKZÚZ, 50050.1 Rosliny oleiste, rosliny straczkowe Oznaczanie wybranych parametrow metoda NIRS Tluszcz  olej  sucha masa  substancje azotowe  Olejniny, lusteniny Stanoveni vybranych parametru metodou NIRS Tuk  olej  susina  dusikate latky  JPP UKZUZ, 50050.1","search_en":"Oil plants, legumes Determination of selected parameters by NIRS method Fat  oil  dry matter  nitrogenous substances  JPP ÚKZÚZ, 50050.1","search_zh":"油料作物、豆类 NIRS法测定选定参数 脂肪  油  干物质  含氮物质  JPP ÚKZÚZ, 50050.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":83,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"052174fb19df7824e4b51bec","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"34","test_object":"Zboża, mąka","test_object_en":"Cereals, flour","test_object_zh":"谷物、面粉","test_object_cs":"Obiloviny, mouka","methodology":"Oznaczanie wybranych parametrów metodą NIRS","methodology_en":"Determination of selected parameters by NIRS method","methodology_zh":"NIRS法测定选定参数","methodology_cs":"Stanovení vybraných parametrů metodou NIRS","parameters":[{"name":"Sucha masa","range":""},{"name":"substancje azotowe","range":""},{"name":"skrobia","range":""},{"name":"popiół","range":""}],"parameters_en":[{"name":"Dry matter","range":""},{"name":"nitrogenous substances","range":""},{"name":"starch","range":""},{"name":"ash","range":""}],"parameters_zh":[{"name":"干物质","range":""},{"name":"含氮物质","range":""},{"name":"淀粉","range":""},{"name":"灰分","range":""}],"parameters_cs":[{"name":"Sušina","range":""},{"name":"dusíkaté látky","range":""},{"name":"škrob","range":""},{"name":"popel","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych parametrów metodą NIRS\nZakres:\nSucha masa\nsubstancje azotowe\nskrobia\npopiół","reference":"JPP ÚKZÚZ, 50050.1","norm_bases":["JPP ÚKZÚZ, 50050.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zboża, mąka Oznaczanie wybranych parametrów metodą NIRS Sucha masa  substancje azotowe  skrobia  popiół  Obiloviny, mouka Stanovení vybraných parametrů metodou NIRS Sušina  dusíkaté látky  škrob  popel  JPP ÚKZÚZ, 50050.1 Zboza, maka Oznaczanie wybranych parametrow metoda NIRS Sucha masa  substancje azotowe  skrobia  popiol  Obiloviny, mouka Stanoveni vybranych parametru metodou NIRS Susina  dusikate latky  skrob  popel  JPP UKZUZ, 50050.1","search_en":"Cereals, flour Determination of selected parameters by NIRS method Dry matter  nitrogenous substances  starch  ash  JPP ÚKZÚZ, 50050.1","search_zh":"谷物、面粉 NIRS法测定选定参数 干物质  含氮物质  淀粉  灰分  JPP ÚKZÚZ, 50050.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":84,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"31766711dd2d29a73a0d8fff","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"35","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości kongenerów wskaźnikowych polichlorowanych bifenyli (PCB) i trwałych pestycydów chloroorganicznych (OCP) metodą GC-MS/MS","methodology_en":"Determination of polychlorinated biphenyls (PCB) indicator congeners and persistent organic chlorinated pesticides (OCP) by GC-MS/MS method","methodology_zh":"GC-MS/MS法测定多氯联苯（PCB）指示性同系物和持久性有机氯农药（OCP）含量","methodology_cs":"Stanovení obsahu indikátorových kongenerů polychlorovaných bifenylů (PCB) a perzistentních organochlorových pesticidů (OCP) metodou GC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości kongenerów wskaźnikowych polichlorowanych bifenyli (PCB) i trwałych pestycydów chloroorganicznych (OCP) metodą GC-MS/MS","reference":"JPP ÚKZÚZ, 30680.1; JPP ÚKZÚZ, 30690.1","norm_bases":["JPP ÚKZÚZ, 30680.1","JPP ÚKZÚZ, 30690.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Oznaczane anality: PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, HCB, alfa-HCH, beta-HCH, gamma-HCH, delta-HCH, o,p´-DDT, o,p´-DDD, o,p´-DDE, p,p´-DDT, p,p´-DDD, p,p´-DDE","note_en":"Determined analytes: PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, HCB, alpha-HCH, beta-HCH, gamma-HCH, delta-HCH, o,p´-DDT, o,p´-DDD, o,p´-DDE, p,p´-DDT, p,p´-DDD, p,p´-DDE","note_zh":"测定分析物：PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, HCB, alpha-HCH, beta-HCH, gamma-HCH, delta-HCH, o,p´-DDT, o,p´-DDD, o,p´-DDE, p,p´-DDT, p,p´-DDD, p,p´-DDE","note_cs":"Stanovované analyty: PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, HCB, alfa-HCH, beta-HCH, gama-HCH, delta-HCH, o,p´-DDT, o,p´-DDD, o,p´-DDE, p,p´-DDT, p,p´-DDD, p,p´-DDE","search_text":"Gleby, osady, osady denne Oznaczanie zawartości kongenerów wskaźnikowych polichlorowanych bifenyli (PCB) i trwałych pestycydów chloroorganicznych (OCP) metodą GC-MS/MS Půdy, kaly, sedimenty Stanovení obsahu indikátorových kongenerů polychlorovaných bifenylů (PCB) a perzistentních organochlorových pesticidů (OCP) metodou GC-MS/MS JPP ÚKZÚZ, 30680.1; JPP ÚKZÚZ, 30690.1 Gleby, osady, osady denne Oznaczanie zawartosci kongenerow wskaznikowych polichlorowanych bifenyli (PCB) i trwalych pestycydow chloroorganicznych (OCP) metoda GC-MS/MS Pudy, kaly, sedimenty Stanoveni obsahu indikatorovych kongeneru polychlorovanych bifenylu (PCB) a perzistentnich organochlorovych pesticidu (OCP) metodou GC-MS/MS JPP UKZUZ, 30680.1; JPP UKZUZ, 30690.1","search_en":"Soil, sludge, sediments Determination of polychlorinated biphenyls (PCB) indicator congeners and persistent organic chlorinated pesticides (OCP) by GC-MS/MS method JPP ÚKZÚZ, 30680.1; JPP ÚKZÚZ, 30690.1","search_zh":"土壤、污泥、沉积物 GC-MS/MS法测定多氯联苯（PCB）指示性同系物和持久性有机氯农药（OCP）含量 JPP ÚKZÚZ, 30680.1; JPP ÚKZÚZ, 30690.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":85,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"97f1e5fbdab45f4d3c6fa90d","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"36","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości kongenerów wskaźnikowych polichlorowanych bifenyli (PCB) i trwałych pestycydów chloroorganicznych (OCP) metodą GC-MS/MS","methodology_en":"Determination of polychlorinated biphenyls (PCB) indicator congeners and persistent organic chlorinated pesticides (OCP) by GC-MS/MS method","methodology_zh":"GC-MS/MS法测定多氯联苯（PCB）指示性同系物和持久性有机氯农药（OCP）含量","methodology_cs":"Stanovení obsahu indikátorových kongenerů polychlorovaných bifenylů (PCB) a perzistentních organochlorových pesticidů (OCP) metodou GC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości kongenerów wskaźnikowych polichlorowanych bifenyli (PCB) i trwałych pestycydów chloroorganicznych (OCP) metodą GC-MS/MS","reference":"JPP ÚKZÚZ, 10580.1; JPP ÚKZÚZ, 10590.1","norm_bases":["JPP ÚKZÚZ, 10580.1","JPP ÚKZÚZ, 10590.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Oznaczane anality: PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, HCB, alfa-HCH, beta-HCH, gamma-HCH, delta-HCH, o,p´-DDT, o,p´-DDD, o,p´-DDE, p,p´-DDT, p,p´-DDD, p,p´-DDE, aldryna, dieldryna, endryna, keton endryny, izodryna, heptachlor, alfa-epoksyd heptachloru, beta-epoksyd heptachloru, alfa-endosulfan, beta-endosulfan, siarczan endosulfanu, alfa-chlordan, gamma-chlordan, oksychlordan, metoksychlor, mireks, kongenery toksafenu Parlar-26, Parlar-32, Parlar-50 i Parlar-62","note_en":"Determined analytes: PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, HCB, alpha-HCH, beta-HCH, gamma-HCH, delta-HCH, o,p´-DDT, o,p´-DDD, o,p´-DDE, p,p´-DDT, p,p´-DDD, p,p´-DDE, aldrin, dieldrin, endrin, endrin-ketone, isodrin, heptachlor, alpha-heptachlorepoxide, beta-heptachlorepoxide, alpha-endosulfan, beta-endosulfan, endosulfan sulphate, alpha-chlordane, gamma-chlordane, oxychlordane, methoxychlor, mirex, toxaphene congeners Parlar-26, Parlar-32, Parlar-50 and Parlar-62","note_zh":"测定分析物：PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, HCB, alpha-HCH, beta-HCH, gamma-HCH, delta-HCH, o,p´-DDT, o,p´-DDD, o,p´-DDE, p,p´-DDT, p,p´-DDD, p,p´-DDE, aldrin, dieldrin, endrin, endrin-ketone, isodrin, heptachlor, alpha-heptachlorepoxide, beta-heptachlorepoxide, alpha-endosulfan, beta-endosulfan, endosulfan sulphate, alpha-chlordane, gamma-chlordane, oxychlordane, methoxychlor, mirex, toxaphene congeners Parlar-26, Parlar-32, Parlar-50 and Parlar-62","note_cs":"Stanovované analyty: PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, PCB180, HCB, alfa-HCH, beta-HCH, gama-HCH, delta-HCH, o,p´-DDT, o,p´-DDD, o,p´-DDE, p,p´-DDT, p,p´-DDD, p,p´-DDE, aldrin, dieldrin, endrin, endrin-keton, isodrin, heptachlor, alfa-heptachlorepoxid, beta-heptachlorepoxid, alfa-endosulfan, beta-endosulfan, endosulfan sulfát, alfa-chlordan, gama-chlordan, oxychlordan, metoxychlor, mirex, kongenery toxafenu Parlar-26, Parlar-32, Parlar-50 a Parlar-62","search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości kongenerów wskaźnikowych polichlorowanych bifenyli (PCB) i trwałych pestycydów chloroorganicznych (OCP) metodą GC-MS/MS Krmiva a suroviny pro jejich výrobu Stanovení obsahu indikátorových kongenerů polychlorovaných bifenylů (PCB) a perzistentních organochlorových pesticidů (OCP) metodou GC-MS/MS JPP ÚKZÚZ, 10580.1; JPP ÚKZÚZ, 10590.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci kongenerow wskaznikowych polichlorowanych bifenyli (PCB) i trwalych pestycydow chloroorganicznych (OCP) metoda GC-MS/MS Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu indikatorovych kongeneru polychlorovanych bifenylu (PCB) a perzistentnich organochlorovych pesticidu (OCP) metodou GC-MS/MS JPP UKZUZ, 10580.1; JPP UKZUZ, 10590.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of polychlorinated biphenyls (PCB) indicator congeners and persistent organic chlorinated pesticides (OCP) by GC-MS/MS method JPP ÚKZÚZ, 10580.1; JPP ÚKZÚZ, 10590.1","search_zh":"饲料及其生产原料 GC-MS/MS法测定多氯联苯（PCB）指示性同系物和持久性有机氯农药（OCP）含量 JPP ÚKZÚZ, 10580.1; JPP ÚKZÚZ, 10590.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":86,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5be7ea0b6907e0c8603384f8","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"37","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości kannabinoidów metodą GC/FID","methodology_en":"Determination of cannabinoids by GC/FID method","methodology_zh":"GC/FID法测定大麻素含量","methodology_cs":"Stanovení obsahu kanabinoidů metodou GC/FID","parameters":[{"name":"THC","range":""},{"name":"CBD","range":""}],"parameters_en":[{"name":"THC","range":""},{"name":"CBD","range":""}],"parameters_zh":[{"name":"THC","range":""},{"name":"CBD","range":""}],"parameters_cs":[{"name":"THC","range":""},{"name":"CBD","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości kannabinoidów metodą GC/FID\nZakres:\nTHC\nCBD","reference":"JPP ÚKZÚZ, 40280.1","norm_bases":["JPP ÚKZÚZ, 40280.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości kannabinoidów metodą GC/FID THC  CBD  Rostlinný materiál Stanovení obsahu kanabinoidů metodou GC/FID THC  CBD  JPP ÚKZÚZ, 40280.1 Material roslinny Oznaczanie zawartosci kannabinoidow metoda GC/FID THC  CBD  Rostlinny material Stanoveni obsahu kanabinoidu metodou GC/FID THC  CBD  JPP UKZUZ, 40280.1","search_en":"Plant material Determination of cannabinoids by GC/FID method THC  CBD  JPP ÚKZÚZ, 40280.1","search_zh":"植物材料 GC/FID法测定大麻素含量 THC  CBD  JPP ÚKZÚZ, 40280.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":87,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2e94e68f7dc3a086ec3bd2ff","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"38","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie wybranych dodatków paszowych metodą HPLC/DAD, FLD","methodology_en":"Determination of selected feed additives by HPLC/DAD, FLD method","methodology_zh":"HPLC/DAD、FLD法测定选定饲料添加剂","methodology_cs":"Stanovení vybraných doplňkových látek metodou HPLC/DAD, FLD","parameters":[{"name":"Salinomycyna","range":""},{"name":"monenzyna","range":""},{"name":"narazyna","range":""},{"name":"robenidyna","range":""},{"name":"nikarbazyna","range":""},{"name":"lasalocyd","range":""}],"parameters_en":[{"name":"Salinomycin","range":""},{"name":"monensin","range":""},{"name":"narasin","range":""},{"name":"robenidin","range":""},{"name":"nicarbazin","range":""},{"name":"lasalocid","range":""}],"parameters_zh":[{"name":"盐霉素","range":""},{"name":"莫能菌素","range":""},{"name":"甲基盐霉素","range":""},{"name":"罗贝胍","range":""},{"name":"尼卡巴嗪","range":""},{"name":"拉沙洛西","range":""}],"parameters_cs":[{"name":"Salinomycin","range":""},{"name":"monensin","range":""},{"name":"narasin","range":""},{"name":"robenidin","range":""},{"name":"nikarbazin","range":""},{"name":"lasalocid","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych dodatków paszowych metodą HPLC/DAD, FLD\nZakres:\nSalinomycyna\nmonenzyna\nnarazyna\nrobenidyna\nnikarbazyna\nlasalocyd","reference":"JPP ÚKZÚZ, 10350.1; JPP ÚKZÚZ, 10360.1; JPP ÚKZÚZ, 10390.1; JPP ÚKZÚZ, 10400.1","norm_bases":["JPP ÚKZÚZ, 10350.1","JPP ÚKZÚZ, 10360.1","JPP ÚKZÚZ, 10390.1","JPP ÚKZÚZ, 10400.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie wybranych dodatków paszowych metodą HPLC/DAD, FLD Salinomycyna  monenzyna  narazyna  robenidyna  nikarbazyna  lasalocyd  Krmiva a suroviny pro jejich výrobu Stanovení vybraných doplňkových látek metodou HPLC/DAD, FLD Salinomycin  monensin  narasin  robenidin  nikarbazin  lasalocid  JPP ÚKZÚZ, 10350.1; JPP ÚKZÚZ, 10360.1; JPP ÚKZÚZ, 10390.1; JPP ÚKZÚZ, 10400.1 Pasze i surowce do ich produkcji Oznaczanie wybranych dodatkow paszowych metoda HPLC/DAD, FLD Salinomycyna  monenzyna  narazyna  robenidyna  nikarbazyna  lasalocyd  Krmiva a suroviny pro jejich vyrobu Stanoveni vybranych doplnkovych latek metodou HPLC/DAD, FLD Salinomycin  monensin  narasin  robenidin  nikarbazin  lasalocid  JPP UKZUZ, 10350.1; JPP UKZUZ, 10360.1; JPP UKZUZ, 10390.1; JPP UKZUZ, 10400.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of selected feed additives by HPLC/DAD, FLD method Salinomycin  monensin  narasin  robenidin  nicarbazin  lasalocid  JPP ÚKZÚZ, 10350.1; JPP ÚKZÚZ, 10360.1; JPP ÚKZÚZ, 10390.1; JPP ÚKZÚZ, 10400.1","search_zh":"饲料及其生产原料 HPLC/DAD、FLD法测定选定饲料添加剂 盐霉素  莫能菌素  甲基盐霉素  罗贝胍  尼卡巴嗪  拉沙洛西  JPP ÚKZÚZ, 10350.1; JPP ÚKZÚZ, 10360.1; JPP ÚKZÚZ, 10390.1; JPP ÚKZÚZ, 10400.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":88,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"88c19545fb190f7cecddb9aa","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"39","test_object":"Pasze i surowce do ich produkcji, materiał roślinny","test_object_en":"Animal feeding stuffs and raw materials for their production, plant material","test_object_zh":"饲料及其生产原料、植物材料","test_object_cs":"Krmiva a suroviny pro jejich výrobu, rostlinný materiál","methodology":"Oznaczanie zawartości pozostałości pestycydów metodą GC-MS","methodology_en":"Determination of pesticide residues by GC-MS method","methodology_zh":"GC-MS法测定农药残留含量","methodology_cs":"Stanovení obsahu reziduí pesticidů metodou GC-MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości pozostałości pestycydów metodą GC-MS","reference":"JPP ÚKZÚZ, 10610.1","norm_bases":["JPP ÚKZÚZ, 10610.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality: Azinphos-ethyl, Azinphos-methyl, Azoxystrobin, Bifenox, Bifenthrin, Bixafen, Boscalid, Bromuconazole, Captan, Carbaryl, Carfentrazone-ethyl, Cyfluthrin, Cyhalothrin-lambda, Cypermethrin, Cyproconazole, Cyprodinil, Deltamethrin, Diazinon, Dicloran, Dicofol, Difenoconazole, Dichlorvos, Dichlormid, Dimethoate, Dimethomorph, Diphenylamine, Endosulfan, Endosulfan sulfate, Epoxiconazole, Ethion, Etofenprox, Ethofumesate, Famoxadone, Fenamidone, Fenbuconazole, Fenhexamid, Fenitrothion, Fenpropidin, Fenpropimorph, Fenthion, Fenvalerate, Fipronil, Flonicamid, Fludioxonil, Flufenacet, Flumioxazin, Fluquinconazole, Flurochloridone, Flusilazole, Flutolanil, Flutriafol, Fluvalinate-tau, Folpet, Isoxadifen-ethyl, Isoxaflutole, Hexaconazole, Chlorfenvinphos, Chlorpropham, Chlorpyrifos, Chlorpyrifos-methyl, Indoxacarb, Iprodione, Iprovalicarb, Isoproturon, Kresoxim-methyl, Malaoxon, Malathion, Mefenpyr-diethyl, Mefentrifluconazole, Metalaxyl, Metconazole, Methacrifos, Methidathion, Metrafenone, Metribuzin, Monocrotophos, Myclobutanil, Napropamide, Nitrofen, Omethoate, Oxyfluorfen, Parathion, Penconazole, Pendimethalin, Permethrin, Phenthoate, Phosalone, Phosmet, Phtalimide, Picoxystrobin, Pirimicarb, Pirimiphos-methyl, Procymidone, Profenofos, Propiconazole, Propyzamide, Pyraflufen-ethyl, Pyrimethanil, Quinoxyfen, Resmethrin, Spiroxamine, Tefluthrin, THPI, Tetraconazole, Triadimefon, Triadimenol, Triazophos, Trifloxystrobin, Trifluralin, Triticonazole, Vinclozolin","note_en":"Determined analytes: Azinphos-ethyl, Azinphos-methyl, Azoxystrobin, Bifenox, Bifenthrin, Bixafen, Boscalid, Bromuconazole, Captan, Carbaryl, Carfentrazone-ethyl, Cyfluthrin, Cyhalothrin-lambda, Cypermethrin, Cyproconazole, Cyprodinil, Deltamethrin, Diazinon, Dicloran, Dicofol, Difenoconazole, Dichlorvos, Dichlormid, Dimethoate, Dimethomorph, Diphenylamine, Endosulfan, Endosulfan sulfate, Epoxiconazole, Ethion, Etofenprox, Ethofumesate, Famoxadone, Fenamidone, Fenbuconazole, Fenhexamid, Fenitrothion, Fenpropidin, Fenpropimorph, Fenthion, Fenvalerate, Fipronil, Flonicamid, Fludioxonil, Flufenacet, Flumioxazin, Fluquinconazole, Flurochloridone, Flusilazole, Flutolanil, Flutriafol, Fluvalinate-tau, Folpet, Isoxadifen-ethyl, Isoxaflutole, Hexaconazole, Chlorfenvinphos, Chlorpropham, Chlorpyrifos, Chlorpyrifos-methyl, Indoxacarb, Iprodione, Iprovalicarb, Isoproturon, Kresoxim-methyl, Malaoxon, Malathion, Mefenpyr-diethyl, Mefentrifluconazole, Metalaxyl, Metconazole, Methacrifos, Methidathion, Metrafenone, Metribuzin, Monocrotophos, Myclobutanil, Napropamide, Nitrofen, Omethoate, Oxyfluorfen, Parathion, Penconazole, Pendimethalin, Permethrin, Phenthoate, Phosalone, Phosmet, Phtalimide, Picoxystrobin, Pirimicarb, Pirimiphos-methyl, Procymidone, Profenofos, Propiconazole, Propyzamide, Pyraflufen-ethyl, Pyrimethanil, Quinoxyfen, Resmethrin, Spiroxamine, Tefluthrin, THPI, Tetraconazole, Triadimefon, Triadimenol, Triazophos, Trifloxystrobin, Trifluralin, Triticonazole, Vinclozolin","note_zh":"测定分析物：Azinphos-ethyl, Azinphos-methyl, Azoxystrobin, Bifenox, Bifenthrin, Bixafen, Boscalid, Bromuconazole, Captan, Carbaryl, Carfentrazone-ethyl, Cyfluthrin, Cyhalothrin-lambda, Cypermethrin, Cyproconazole, Cyprodinil, Deltamethrin, Diazinon, Dicloran, Dicofol, Difenoconazole, Dichlorvos, Dichlormid, Dimethoate, Dimethomorph, Diphenylamine, Endosulfan, Endosulfan sulfate, Epoxiconazole, Ethion, Etofenprox, Ethofumesate, Famoxadone, Fenamidone, Fenbuconazole, Fenhexamid, Fenitrothion, Fenpropidin, Fenpropimorph, Fenthion, Fenvalerate, Fipronil, Flonicamid, Fludioxonil, Flufenacet, Flumioxazin, Fluquinconazole, Flurochloridone, Flusilazole, Flutolanil, Flutriafol, Fluvalinate-tau, Folpet, Isoxadifen-ethyl, Isoxaflutole, Hexaconazole, Chlorfenvinphos, Chlorpropham, Chlorpyrifos, Chlorpyrifos-methyl, Indoxacarb, Iprodione, Iprovalicarb, Isoproturon, Kresoxim-methyl, Malaoxon, Malathion, Mefenpyr-diethyl, Mefentrifluconazole, Metalaxyl, Metconazole, Methacrifos, Methidathion, Metrafenone, Metribuzin, Monocrotophos, Myclobutanil, Napropamide, Nitrofen, Omethoate, Oxyfluorfen, Parathion, Penconazole, Pendimethalin, Permethrin, Phenthoate, Phosalone, Phosmet, Phtalimide, Picoxystrobin, Pirimicarb, Pirimiphos-methyl, Procymidone, Profenofos, Propiconazole, Propyzamide, Pyraflufen-ethyl, Pyrimethanil, Quinoxyfen, Resmethrin, Spiroxamine, Tefluthrin, THPI, Tetraconazole, Triadimefon, Triadimenol, Triazophos, Trifloxystrobin, Trifluralin, Triticonazole, Vinclozolin","note_cs":"Stanovované analyty: Azinphos-ethyl, Azinphos-methyl, Azoxystrobin, Bifenox, Bifenthrin, Bixafen, Boscalid, Bromuconazole, Captan, Carbaryl, Carfentrazone-ethyl, Cyfluthrin, Cyhalothrin-lambda, Cypermethrin, Cyproconazole, Cyprodinil, Deltamethrin, Diazinon, Dicloran, Dicofol, Difenoconazole, Dichlorvos, Dichlormid, Dimethoate, Dimethomorph, Diphenylamine, Endosulfan, Endosulfan sulfate, Epoxiconazole, Ethion, Etofenprox, Ethofumesate, Famoxadone, Fenamidone, Fenbuconazole, Fenhexamid, Fenitrothion, Fenpropidin, Fenpropimorph, Fenthion, Fenvalerate, Fipronil, Flonicamid, Fludioxonil, Flufenacet, Flumioxazin, Fluquinconazole, Flurochloridone, Flusilazole, Flutolanil, Flutriafol, Fluvalinate-tau, Folpet, Isoxadifen-ethyl, Isoxaflutole, Hexaconazole, Chlorfenvinphos, Chlorpropham, Chlorpyrifos, Chlorpyrifos-methyl, Indoxacarb, Iprodione, Iprovalicarb, Isoproturon, Kresoxim-methyl, Malaoxon, Malathion, Mefenpyr-diethyl, Mefentrifluconazole, Metalaxyl, Metconazole, Methacrifos, Methidathion, Metrafenone, Metribuzin, Monocrotophos, Myclobutanil, Napropamide, Nitrofen, Omethoate, Oxyfluorfen, Parathion, Penconazole, Pendimethalin, Permethrin, Phenthoate, Phosalone, Phosmet, Phtalimide, Picoxystrobin, Pirimicarb, Pirimiphos-methyl, Procymidone, Profenofos, Propiconazole, Propyzamide, Pyraflufen-ethyl, Pyrimethanil, Quinoxyfen, Resmethrin, Spiroxamine, Tefluthrin, THPI, Tetraconazole, Triadimefon, Triadimenol, Triazophos, Trifloxystrobin, Trifluralin, Triticonazole, Vinclozolin","search_text":"Pasze i surowce do ich produkcji, materiał roślinny Oznaczanie zawartości pozostałości pestycydów metodą GC-MS Krmiva a suroviny pro jejich výrobu, rostlinný materiál Stanovení obsahu reziduí pesticidů metodou GC-MS JPP ÚKZÚZ, 10610.1 Pasze i surowce do ich produkcji, material roslinny Oznaczanie zawartosci pozostalosci pestycydow metoda GC-MS Krmiva a suroviny pro jejich vyrobu, rostlinny material Stanoveni obsahu rezidui pesticidu metodou GC-MS JPP UKZUZ, 10610.1","search_en":"Animal feeding stuffs and raw materials for their production, plant material Determination of pesticide residues by GC-MS method JPP ÚKZÚZ, 10610.1","search_zh":"饲料及其生产原料、植物材料 GC-MS法测定农药残留含量 JPP ÚKZÚZ, 10610.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":89,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c41f8d9712e34b36ee6dcefd","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"40","test_object":"Pasze i surowce do ich produkcji, materiał roślinny","test_object_en":"Animal feeding stuffs and raw materials for their production, plant material","test_object_zh":"饲料及其生产原料、植物材料","test_object_cs":"Krmiva a suroviny pro jejich výrobu, rostlinný materiál","methodology":"Oznaczanie zawartości pozostałości pestycydów metodą LC-MS","methodology_en":"Determination of pesticide residues by LC-MS method","methodology_zh":"LC-MS法测定农药残留含量","methodology_cs":"Stanovení obsahu reziduí pesticidů metodou LC-MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości pozostałości pestycydów metodą LC-MS","reference":"JPP ÚKZÚZ, 10600.1","norm_bases":["JPP ÚKZÚZ, 10600.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality: 2,4-D, Acephate, Acetamiprid, Acetochlor, Aclonifen, Alachlor, Amidosulfuron, Aminopyralid, Atrazine, Azadirachtin, Azinphos-methyl, Azoxystrobin, Benalaxyl, Bentazone, Benzovindiflupyr, Bitertanol, Bixafen, Boscalid, Bromoxynil, Bromuconazole, Carbaryl, Carbendazim, Carbofuran, Carbofuran-3-hydroxy, Carboxin, Carfentrazone-ethyl, Clomazone, Clopyralid, Clothianidin, Cyantraniliprole, Cyazofamid, Cyflufenamid, Cymoxanil, Cyproconazole, Cyprodinil, Demeton-S-methylsulfone, Desmedipham, Diazinon, Difenoconazole, Diflubenzuron, Diflufenican, Dichlorprop, Dichlorvos, Dimethachlor, Dimethenamid, Dimethoate, Dimethomorph, Dimoxystrobin, Diuron, Epoxiconazole, Ethofumesate, Famoxadone, Fenamidone, Fenbuconazole, Fenhexamid, Fenoxaprop-P, Fenoxaprop-P-ethyl, Fenpropidin, Fenpropimorph, Fenthion, Fenpyroximate, Florasulam, Fluazifop, Fluazifop-P-butyl, Fluazinam, Fludioxonil, Flufenacet, Fluopicolide, Fluopyram, Fluoxastrobin, Flupyradifuron, Flurochloridone, Fluquinconazole, Fluroxypyr, Flusilazole, Flutolanil, Flutriafol, Fluvalinate-tau, Fluxapyroxad, Foramsulfuron, Forchlorfenuron, Halauxifen-methyl, Haloxyfop, Haloxyfop-etotyl, Haloxyfop-methyl, Hexaconazole, Hexazinone, Hexythiazox, Chlorantraniliprole, Chloridazon, Chlorotoluron, Chlorpropham Chlorpyrifos, Chlorpyrifos-methyl, Chlorsulfuron, Imazalil, Imazamox, Imidacloprid, Indoxacarb, Iodosulfuron-methyl, Iprodione, Iprovalicarb, Isofetamid, Isoproturon, Isoxaflutole, Kresoxim-methyl, Linuron, Lenacil, Malaoxon, Malathion, Mandestrobin, Mandipropamid, MCPA, MCPB, Mecoprop, Mefenpyr-diethyl, Mefentrifluconazole, Mesosulfuron-methyl, Mesotrione, Metalaxyl, Metamitron, Metazachlor, Metconazole, Metobromuron, Methiocarb, Methiocarb sulfone, Methomyl, Methoxyfenozide, Metolachlor, Metrafenone, Metribuzin, Metsulfuron-methyl, Monocrotophos, Myclobutanil, Napropamide, Nicosulfuron, Omethoate, Paclobutrazol, Penconazole, Pencycuron, Pendimethalin, Penoxsulam, Pethoxamid, Phenmedipham, Phosalone, Phosmet, Phosphamidon, Picloram, Picolinafen, Picoxystrobin, Pinoxaden, Pirimicarb, Pirimicarb-desmethyl, Pirimiphos-methyl, Prochloraz, Propamocarb, Prometryn, Propachlor, Propaquizafop, Propiconazole, Propyzamide, Proquinazid, Prosulfocarb, Prothioconazole-desthio, Pyraclostrobin, Pyraflufen-ethyl, Pyridaben, Pyridate, Pyrimethanil, Pyriproxyfen, Pyroxsulam, Quinclorac, Quinmerac, Quinoxyfen, Quizalofop-P, Quizalofop-P-ethyl, Quizalofop-P-tefuryl, Oxydemeton-methyl, Rimsulfuron, Silthiofam, Simazine, Spinosad, Spinosyn A, Spinosyn D, Spiroxamine, Sulfosulfuron, Tebuconazole, Tebufenozide, Tebufenpyrad, Tembotrione, Terbuthylazine, Terbutryn, Tetraconazole, Thiabendazole, Thiacloprid, Thiamethoxam, Thiencarbazone-methyl, Thifensulfuron-methyl, Thiodicarb, Thiophanate-methyl, Triadimefon, Triadimenol, Tri-allate, Triasulfuron, Triazophos, Tribenuron-methyl, Triclopyr, Trifloxystrobin, Triflusulfuron-methyl, Trinexapac, Trinexapac-ethyl, Triticonazole, Tritosulfuron, Zoxamide","note_en":"Determined analytes: 2,4-D, Acephate, Acetamiprid, Acetochlor, Aclonifen, Alachlor, Amidosulfuron, Aminopyralid, Atrazine, Azadirachtin, Azinphos-methyl, Azoxystrobin, Benalaxyl, Bentazone, Benzovindiflupyr, Bitertanol, Bixafen, Boscalid, Bromoxynil, Bromuconazole, Carbaryl, Carbendazim, Carbofuran, Carbofuran-3-hydroxy, Carboxin, Carfentrazone-ethyl, Clomazone, Clopyralid, Clothianidin, Cyantraniliprole, Cyazofamid, Cyflufenamid, Cymoxanil, Cyproconazole, Cyprodinil, Demeton-S-methylsulfone, Desmedipham, Diazinon, Difenoconazole, Diflubenzuron, Diflufenican, Dichlorprop, Dichlorvos, Dimethachlor, Dimethenamid, Dimethoate, Dimethomorph, Dimoxystrobin, Diuron, Epoxiconazole, Ethofumesate, Famoxadone, Fenamidone, Fenbuconazole, Fenhexamid, Fenoxaprop-P, Fenoxaprop-P-ethyl, Fenpropidin, Fenpropimorph, Fenthion, Fenpyroximate, Florasulam, Fluazifop, Fluazifop-P-butyl, Fluazinam, Fludioxonil, Flufenacet, Fluopicolide, Fluopyram, Fluoxastrobin, Flupyradifuron, Flurochloridone, Fluquinconazole, Fluroxypyr, Flusilazole, Flutolanil, Flutriafol, Fluvalinate-tau, Fluxapyroxad, Foramsulfuron, Forchlorfenuron, Halauxifen-methyl, Haloxyfop, Haloxyfop-etotyl, Haloxyfop-methyl, Hexaconazole, Hexazinone, Hexythiazox, Chlorantraniliprole, Chloridazon, Chlorotoluron, Chlorpropham Chlorpyrifos, Chlorpyrifos-methyl, Chlorsulfuron, Imazalil, Imazamox, Imidacloprid, Indoxacarb, Iodosulfuron-methyl, Iprodione, Iprovalicarb, Isofetamid, Isoproturon, Isoxaflutole, Kresoxim-methyl, Linuron, Lenacil, Malaoxon, Malathion, Mandestrobin, Mandipropamid, MCPA, MCPB, Mecoprop, Mefenpyr-diethyl, Mefentrifluconazole, Mesosulfuron-methyl, Mesotrione, Metalaxyl, Metamitron, Metazachlor, Metconazole, Metobromuron, Methiocarb, Methiocarb sulfone, Methomyl, Methoxyfenozide, Metolachlor, Metrafenone, Metribuzin, Metsulfuron-methyl, Monocrotophos, Myclobutanil, Napropamide, Nicosulfuron, Omethoate, Paclobutrazol, Penconazole, Pencycuron, Pendimethalin, Penoxsulam, Pethoxamid, Phenmedipham, Phosalone, Phosmet, Phosphamidon, Picloram, Picolinafen, Picoxystrobin, Pinoxaden, Pirimicarb, Pirimicarb-desmethyl, Pirimiphos-methyl, Prochloraz, Propamocarb, Prometryn, Propachlor, Propaquizafop, Propiconazole, Propyzamide, Proquinazid, Prosulfocarb, Prothioconazole-desthio, Pyraclostrobin, Pyraflufen-ethyl, Pyridaben, Pyridate, Pyrimethanil, Pyriproxyfen, Pyroxsulam, Quinclorac, Quinmerac, Quinoxyfen, Quizalofop-P, Quizalofop-P-ethyl, Quizalofop-P-tefuryl, Oxydemeton-methyl, Rimsulfuron, Silthiofam, Simazine, Spinosad, Spinosyn A, Spinosyn D, Spiroxamine, Sulfosulfuron, Tebuconazole, Tebufenozide, Tebufenpyrad, Tembotrione, Terbuthylazine, Terbutryn, Tetraconazole, Thiabendazole, Thiacloprid, Thiamethoxam, Thiencarbazone-methyl, Thifensulfuron-methyl, Thiodicarb, Thiophanate-methyl, Triadimefon, Triadimenol, Tri-allate, Triasulfuron, Triazophos, Tribenuron-methyl, Triclopyr, Trifloxystrobin, Triflusulfuron-methyl, Trinexapac, Trinexapac-ethyl, Triticonazole, Tritosulfuron, Zoxamide","note_zh":"测定分析物：2,4-D, Acephate, Acetamiprid, Acetochlor, Aclonifen, Alachlor, Amidosulfuron, Aminopyralid, Atrazine, Azadirachtin, Azinphos-methyl, Azoxystrobin, Benalaxyl, Bentazone, Benzovindiflupyr, Bitertanol, Bixafen, Boscalid, Bromoxynil, Bromuconazole, Carbaryl, Carbendazim, Carbofuran, Carbofuran-3-hydroxy, Carboxin, Carfentrazone-ethyl, Clomazone, Clopyralid, Clothianidin, Cyantraniliprole, Cyazofamid, Cyflufenamid, Cymoxanil, Cyproconazole, Cyprodinil, Demeton-S-methylsulfone, Desmedipham, Diazinon, Difenoconazole, Diflubenzuron, Diflufenican, Dichlorprop, Dichlorvos, Dimethachlor, Dimethenamid, Dimethoate, Dimethomorph, Dimoxystrobin, Diuron, Epoxiconazole, Ethofumesate, Famoxadone, Fenamidone, Fenbuconazole, Fenhexamid, Fenoxaprop-P, Fenoxaprop-P-ethyl, Fenpropidin, Fenpropimorph, Fenthion, Fenpyroximate, Florasulam, Fluazifop, Fluazifop-P-butyl, Fluazinam, Fludioxonil, Flufenacet, Fluopicolide, Fluopyram, Fluoxastrobin, Flupyradifuron, Flurochloridone, Fluquinconazole, Fluroxypyr, Flusilazole, Flutolanil, Flutriafol, Fluvalinate-tau, Fluxapyroxad, Foramsulfuron, Forchlorfenuron, Halauxifen-methyl, Haloxyfop, Haloxyfop-etotyl, Haloxyfop-methyl, Hexaconazole, Hexazinone, Hexythiazox, Chlorantraniliprole, Chloridazon, Chlorotoluron, Chlorpropham Chlorpyrifos, Chlorpyrifos-methyl, Chlorsulfuron, Imazalil, Imazamox, Imidacloprid, Indoxacarb, Iodosulfuron-methyl, Iprodione, Iprovalicarb, Isofetamid, Isoproturon, Isoxaflutole, Kresoxim-methyl, Linuron, Lenacil, Malaoxon, Malathion, Mandestrobin, Mandipropamid, MCPA, MCPB, Mecoprop, Mefenpyr-diethyl, Mefentrifluconazole, Mesosulfuron-methyl, Mesotrione, Metalaxyl, Metamitron, Metazachlor, Metconazole, Metobromuron, Methiocarb, Methiocarb sulfone, Methomyl, Methoxyfenozide, Metolachlor, Metrafenone, Metribuzin, Metsulfuron-methyl, Monocrotophos, Myclobutanil, Napropamide, Nicosulfuron, Omethoate, Paclobutrazol, Penconazole, Pencycuron, Pendimethalin, Penoxsulam, Pethoxamid, Phenmedipham, Phosalone, Phosmet, Phosphamidon, Picloram, Picolinafen, Picoxystrobin, Pinoxaden, Pirimicarb, Pirimicarb-desmethyl, Pirimiphos-methyl, Prochloraz, Propamocarb, Prometryn, Propachlor, Propaquizafop, Propiconazole, Propyzamide, Proquinazid, Prosulfocarb, Prothioconazole-desthio, Pyraclostrobin, Pyraflufen-ethyl, Pyridaben, Pyridate, Pyrimethanil, Pyriproxyfen, Pyroxsulam, Quinclorac, Quinmerac, Quinoxyfen, Quizalofop-P, Quizalofop-P-ethyl, Quizalofop-P-tefuryl, Oxydemeton-methyl, Rimsulfuron, Silthiofam, Simazine, Spinosad, Spinosyn A, Spinosyn D, Spiroxamine, Sulfosulfuron, Tebuconazole, Tebufenozide, Tebufenpyrad, Tembotrione, Terbuthylazine, Terbutryn, Tetraconazole, Thiabendazole, Thiacloprid, Thiamethoxam, Thiencarbazone-methyl, Thifensulfuron-methyl, Thiodicarb, Thiophanate-methyl, Triadimefon, Triadimenol, Tri-allate, Triasulfuron, Triazophos, Tribenuron-methyl, Triclopyr, Trifloxystrobin, Triflusulfuron-methyl, Trinexapac, Trinexapac-ethyl, Triticonazole, Tritosulfuron, Zoxamide","note_cs":"Stanovované analyty: 2,4-D, Acephate, Acetamiprid, Acetochlor, Aclonifen, Alachlor, Amidosulfuron, Aminopyralid, Atrazine, Azadirachtin, Azinphos-methyl, Azoxystrobin, Benalaxyl, Bentazone, Benzovindiflupyr, Bitertanol, Bixafen, Boscalid, Bromoxynil, Bromuconazole, Carbaryl, Carbendazim, Carbofuran, Carbofuran-3-hydroxy, Carboxin, Carfentrazone-ethyl, Clomazone, Clopyralid, Clothianidin, Cyantraniliprole, Cyazofamid, Cyflufenamid, Cymoxanil, Cyproconazole, Cyprodinil, Demeton-S-methylsulfone, Desmedipham, Diazinon, Difenoconazole, Diflubenzuron, Diflufenican, Dichlorprop, Dichlorvos, Dimethachlor, Dimethenamid, Dimethoate, Dimethomorph, Dimoxystrobin, Diuron, Epoxiconazole, Ethofumesate, Famoxadone, Fenamidone, Fenbuconazole, Fenhexamid, Fenoxaprop-P, Fenoxaprop-P-ethyl, Fenpropidin, Fenpropimorph, Fenthion, Fenpyroximate, Florasulam, Fluazifop, Fluazifop-P-butyl, Fluazinam, Fludioxonil, Flufenacet, Fluopicolide, Fluopyram, Fluoxastrobin, Flupyradifuron, Flurochloridone, Fluquinconazole, Fluroxypyr, Flusilazole, Flutolanil, Flutriafol, Fluvalinate-tau, Fluxapyroxad, Foramsulfuron, Forchlorfenuron, Halauxifen-methyl, Haloxyfop, Haloxyfop-etotyl, Haloxyfop-methyl, Hexaconazole, Hexazinone, Hexythiazox, Chlorantraniliprole, Chloridazon, Chlorotoluron, Chlorpropham Chlorpyrifos, Chlorpyrifos-methyl, Chlorsulfuron, Imazalil, Imazamox, Imidacloprid, Indoxacarb, Iodosulfuron-methyl, Iprodione, Iprovalicarb, Isofetamid, Isoproturon, Isoxaflutole, Kresoxim-methyl, Linuron, Lenacil, Malaoxon, Malathion, Mandestrobin, Mandipropamid, MCPA, MCPB, Mecoprop, Mefenpyr-diethyl, Mefentrifluconazole, Mesosulfuron-methyl, Mesotrione, Metalaxyl, Metamitron, Metazachlor, Metconazole, Metobromuron, Methiocarb, Methiocarb sulfone, Methomyl, Methoxyfenozide, Metolachlor, Metrafenone, Metribuzin, Metsulfuron-methyl, Monocrotophos, Myclobutanil, Napropamide, Nicosulfuron, Omethoate, Paclobutrazol, Penconazole, Pencycuron, Pendimethalin, Penoxsulam, Pethoxamid, Phenmedipham, Phosalone, Phosmet, Phosphamidon, Picloram, Picolinafen, Picoxystrobin, Pinoxaden, Pirimicarb, Pirimicarb-desmethyl, Pirimiphos-methyl, Prochloraz, Propamocarb, Prometryn, Propachlor, Propaquizafop, Propiconazole, Propyzamide, Proquinazid, Prosulfocarb, Prothioconazole-desthio, Pyraclostrobin, Pyraflufen-ethyl, Pyridaben, Pyridate, Pyrimethanil, Pyriproxyfen, Pyroxsulam, Quinclorac, Quinmerac, Quinoxyfen, Quizalofop-P, Quizalofop-P-ethyl, Quizalofop-P-tefuryl, Oxydemeton-methyl, Rimsulfuron, Silthiofam, Simazine, Spinosad, Spinosyn A, Spinosyn D, Spiroxamine, Sulfosulfuron, Tebuconazole, Tebufenozide, Tebufenpyrad, Tembotrione, Terbuthylazine, Terbutryn, Tetraconazole, Thiabendazole, Thiacloprid, Thiamethoxam, Thiencarbazone-methyl, Thifensulfuron-methyl, Thiodicarb, Thiophanate-methyl, Triadimefon, Triadimenol, Tri-allate, Triasulfuron, Triazophos, Tribenuron-methyl, Triclopyr, Trifloxystrobin, Triflusulfuron-methyl, Trinexapac, Trinexapac-ethyl, Triticonazole, Tritosulfuron, Zoxamide","search_text":"Pasze i surowce do ich produkcji, materiał roślinny Oznaczanie zawartości pozostałości pestycydów metodą LC-MS Krmiva a suroviny pro jejich výrobu, rostlinný materiál Stanovení obsahu reziduí pesticidů metodou LC-MS JPP ÚKZÚZ, 10600.1 Pasze i surowce do ich produkcji, material roslinny Oznaczanie zawartosci pozostalosci pestycydow metoda LC-MS Krmiva a suroviny pro jejich vyrobu, rostlinny material Stanoveni obsahu rezidui pesticidu metodou LC-MS JPP UKZUZ, 10600.1","search_en":"Animal feeding stuffs and raw materials for their production, plant material Determination of pesticide residues by LC-MS method JPP ÚKZÚZ, 10600.1","search_zh":"饲料及其生产原料、植物材料 LC-MS法测定农药残留含量 JPP ÚKZÚZ, 10600.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":90,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"30c646e6e0d39a93d628cada","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"41","test_object":"Gleby","test_object_en":"Soil","test_object_zh":"土壤","test_object_cs":"Půdy","methodology":"Oznaczanie zawartości pozostałości pestycydów metodą LC-MS","methodology_en":"Determination of pesticide residues by LC-MS method","methodology_zh":"LC-MS法测定农药残留含量","methodology_cs":"Stanovení obsahu reziduí pesticidů metodou LC-MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości pozostałości pestycydów metodą LC-MS","reference":"JPP ÚKZÚZ, 10600.1","norm_bases":["JPP ÚKZÚZ, 10600.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Oznaczane anality: 2,4-D, Acetamiprid, Acetochlor, Aclonifen, Alachlor, Amidosulfuron, Aminopyralid, Asulam, Atrazine, Atrazine-2-hydroxy, Atrazine-desethyl, Atrazine-desethyl-desisopropyl, Atrazine-desisopropyl, Azoxystrobin, Bentazone, Boscalid, Bromoxynil, Carbendazim, Clomazone, Clopyralid, Cyflufenamid, Cymoxanil, Cyproconazole, Desmedipham, Dicamba, Dichlorprop, Difenoconazole, Diflufenican, Dimethachlor, Dimethenamid, Dimethoate, Dimethomorph, Dimoxystrobin, Diuron, Epoxiconazole, Ethofumesate, Fenhexamid, Fenpropidin, Fenpropimorph, Fenpyroximate, Florasulam, Fluazifop, Fluazifop-P-butyl, Fludioxonil, Flufenacet, Fluopicolide, Fluopyram, Fluoxastrobin, Flurochloridone, Fluroxypyr, Flusilazole, Fluvalinate-tau, Foramsulfuron, Haloxyfop, Haloxyfop-methyl, Hexazinone, Chlorantraniliprole, Chloridazon, Chlorotoluron, Chlorpropham, Chlorpyrifos, Chlorsulfuron, Imazamox, Iodosulfuron-methyl, Iprovalicarb, Isoproturon, Isoxaflutole, Lenacil, Linuron, MCPA, Mecoprop, Mefenpyr-diethyl, Mesotrione, Metalaxyl, Metamitron, Metazachlor, Metconazole, Methomyl, Methoxyfenozide, Metolachlor, Metribuzin, Metsulfuron-methyl, Napropamide, Nicosulfuron, Omethoate, Penconazole, Pendimethalin, Pethoxamid, Phenmedipham, Picloram, Picoxystrobin, Pinoxaden, Pirimiphos-methyl, Prochloraz, Prometryn, Propachlor, Propamocarb, Propaquizafop, Propiconazole, Propyzamide, Proquinazid, Prothioconazole-desthio, Pyraclostrobin, Pyridate, Pyroxsulam, Quinclorac, Quinmerac, Quinoxyfen, Quizalofop, Quizalofop-P-ethyl, Rimsulfuron, Simazine, Spiroxamine, Sulfosulfuron, Tebuconazole, Tebufenpyrad, Terbuthylazine, Terbuthylazine-2-hydroxy, Terbuthylazine-desethyl, Terbutryn, Tetraconazole, Thiacloprid, Thiencarbazone-methyl, Thifensulfuron-methyl, Thiophanate-methyl, Triadimenol, Triasulfuron, Triclopyr, Trifloxystrobin, Trinexapac-ethyl, Tritosulfuron","note_en":"Determined analytes: 2,4-D, Acetamiprid, Acetochlor, Aclonifen, Alachlor, Amidosulfuron, Aminopyralid, Asulam, Atrazine, Atrazine-2-hydroxy, Atrazine-desethyl, Atrazine-desethyl-desisopropyl, Atrazine-desisopropyl, Azoxystrobin, Bentazone, Boscalid, Bromoxynil, Carbendazim, Clomazone, Clopyralid, Cyflufenamid, Cymoxanil, Cyproconazole, Desmedipham, Dicamba, Dichlorprop, Difenoconazole, Diflufenican, Dimethachlor, Dimethenamid, Dimethoate, Dimethomorph, Dimoxystrobin, Diuron, Epoxiconazole, Ethofumesate, Fenhexamid, Fenpropidin, Fenpropimorph, Fenpyroximate, Florasulam, Fluazifop, Fluazifop-P-butyl, Fludioxonil, Flufenacet, Fluopicolide, Fluopyram, Fluoxastrobin, Flurochloridone, Fluroxypyr, Flusilazole, Fluvalinate-tau, Foramsulfuron, Haloxyfop, Haloxyfop-methyl, Hexazinone, Chlorantraniliprole, Chloridazon, Chlorotoluron, Chlorpropham, Chlorpyrifos, Chlorsulfuron, Imazamox, Iodosulfuron-methyl, Iprovalicarb, Isoproturon, Isoxaflutole, Lenacil, Linuron, MCPA, Mecoprop, Mefenpyr-diethyl, Mesotrione, Metalaxyl, Metamitron, Metazachlor, Metconazole, Methomyl, Methoxyfenozide, Metolachlor, Metribuzin, Metsulfuron-methyl, Napropamide, Nicosulfuron, Omethoate, Penconazole, Pendimethalin, Pethoxamid, Phenmedipham, Picloram, Picoxystrobin, Pinoxaden, Pirimiphos-methyl, Prochloraz, Prometryn, Propachlor, Propamocarb, Propaquizafop, Propiconazole, Propyzamide, Proquinazid, Prothioconazole-desthio, Pyraclostrobin, Pyridate, Pyroxsulam, Quinclorac, Quinmerac, Quinoxyfen, Quizalofop, Quizalofop-P-ethyl, Rimsulfuron, Simazine, Spiroxamine, Sulfosulfuron, Tebuconazole, Tebufenpyrad, Terbuthylazine, Terbuthylazine-2-hydroxy, Terbuthylazine-desethyl, Terbutryn, Tetraconazole, Thiacloprid, Thiencarbazone-methyl, Thifensulfuron-methyl, Thiophanate-methyl, Triadimenol, Triasulfuron, Triclopyr, Trifloxystrobin, Trinexapac-ethyl, Tritosulfuron","note_zh":"测定分析物：2,4-D, Acetamiprid, Acetochlor, Aclonifen, Alachlor, Amidosulfuron, Aminopyralid, Asulam, Atrazine, Atrazine-2-hydroxy, Atrazine-desethyl, Atrazine-desethyl-desisopropyl, Atrazine-desisopropyl, Azoxystrobin, Bentazone, Boscalid, Bromoxynil, Carbendazim, Clomazone, Clopyralid, Cyflufenamid, Cymoxanil, Cyproconazole, Desmedipham, Dicamba, Dichlorprop, Difenoconazole, Diflufenican, Dimethachlor, Dimethenamid, Dimethoate, Dimethomorph, Dimoxystrobin, Diuron, Epoxiconazole, Ethofumesate, Fenhexamid, Fenpropidin, Fenpropimorph, Fenpyroximate, Florasulam, Fluazifop, Fluazifop-P-butyl, Fludioxonil, Flufenacet, Fluopicolide, Fluopyram, Fluoxastrobin, Flurochloridone, Fluroxypyr, Flusilazole, Fluvalinate-tau, Foramsulfuron, Haloxyfop, Haloxyfop-methyl, Hexazinone, Chlorantraniliprole, Chloridazon, Chlorotoluron, Chlorpropham, Chlorpyrifos, Chlorsulfuron, Imazamox, Iodosulfuron-methyl, Iprovalicarb, Isoproturon, Isoxaflutole, Lenacil, Linuron, MCPA, Mecoprop, Mefenpyr-diethyl, Mesotrione, Metalaxyl, Metamitron, Metazachlor, Metconazole, Methomyl, Methoxyfenozide, Metolachlor, Metribuzin, Metsulfuron-methyl, Napropamide, Nicosulfuron, Omethoate, Penconazole, Pendimethalin, Pethoxamid, Phenmedipham, Picloram, Picoxystrobin, Pinoxaden, Pirimiphos-methyl, Prochloraz, Prometryn, Propachlor, Propamocarb, Propaquizafop, Propiconazole, Propyzamide, Proquinazid, Prothioconazole-desthio, Pyraclostrobin, Pyridate, Pyroxsulam, Quinclorac, Quinmerac, Quinoxyfen, Quizalofop, Quizalofop-P-ethyl, Rimsulfuron, Simazine, Spiroxamine, Sulfosulfuron, Tebuconazole, Tebufenpyrad, Terbuthylazine, Terbuthylazine-2-hydroxy, Terbuthylazine-desethyl, Terbutryn, Tetraconazole, Thiacloprid, Thiencarbazone-methyl, Thifensulfuron-methyl, Thiophanate-methyl, Triadimenol, Triasulfuron, Triclopyr, Trifloxystrobin, Trinexapac-ethyl, Tritosulfuron","note_cs":"Stanovované analyty: 2,4-D, Acetamiprid, Acetochlor, Aclonifen, Alachlor, Amidosulfuron, Aminopyralid, Asulam, Atrazine, Atrazine-2-hydroxy, Atrazine-desethyl, Atrazine-desethyl-desisopropyl, Atrazine-desisopropyl, Azoxystrobin, Bentazone, Boscalid, Bromoxynil, Carbendazim, Clomazone, Clopyralid, Cyflufenamid, Cymoxanil, Cyproconazole, Desmedipham, Dicamba, Dichlorprop, Difenoconazole, Diflufenican, Dimethachlor, Dimethenamid, Dimethoate, Dimethomorph, Dimoxystrobin, Diuron, Epoxiconazole, Ethofumesate, Fenhexamid, Fenpropidin, Fenpropimorph, Fenpyroximate, Florasulam, Fluazifop, Fluazifop-P-butyl, Fludioxonil, Flufenacet, Fluopicolide, Fluopyram, Fluoxastrobin, Flurochloridone, Fluroxypyr, Flusilazole, Fluvalinate-tau, Foramsulfuron, Haloxyfop, Haloxyfop-methyl, Hexazinone, Chlorantraniliprole, Chloridazon, Chlorotoluron, Chlorpropham, Chlorpyrifos, Chlorsulfuron, Imazamox, Iodosulfuron-methyl, Iprovalicarb, Isoproturon, Isoxaflutole, Lenacil, Linuron, MCPA, Mecoprop, Mefenpyr-diethyl, Mesotrione, Metalaxyl, Metamitron, Metazachlor, Metconazole, Methomyl, Methoxyfenozide, Metolachlor, Metribuzin, Metsulfuron-methyl, Napropamide, Nicosulfuron, Omethoate, Penconazole, Pendimethalin, Pethoxamid, Phenmedipham, Picloram, Picoxystrobin, Pinoxaden, Pirimiphos-methyl, Prochloraz, Prometryn, Propachlor, Propamocarb, Propaquizafop, Propiconazole, Propyzamide, Proquinazid, Prothioconazole-desthio, Pyraclostrobin, Pyridate, Pyroxsulam, Quinclorac, Quinmerac, Quinoxyfen, Quizalofop, Quizalofop-P-ethyl, Rimsulfuron, Simazine, Spiroxamine, Sulfosulfuron, Tebuconazole, Tebufenpyrad, Terbuthylazine, Terbuthylazine-2-hydroxy, Terbuthylazine-desethyl, Terbutryn, Tetraconazole, Thiacloprid, Thiencarbazone-methyl, Thifensulfuron-methyl, Thiophanate-methyl, Triadimenol, Triasulfuron, Triclopyr, Trifloxystrobin, Trinexapac-ethyl, Tritosulfuron","search_text":"Gleby Oznaczanie zawartości pozostałości pestycydów metodą LC-MS Půdy Stanovení obsahu reziduí pesticidů metodou LC-MS JPP ÚKZÚZ, 10600.1 Gleby Oznaczanie zawartosci pozostalosci pestycydow metoda LC-MS Pudy Stanoveni obsahu rezidui pesticidu metodou LC-MS JPP UKZUZ, 10600.1","search_en":"Soil Determination of pesticide residues by LC-MS method JPP ÚKZÚZ, 10600.1","search_zh":"土壤 LC-MS法测定农药残留含量 JPP ÚKZÚZ, 10600.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":91,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"14c77025ee62bc00105c234f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"42","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie wybranych pierwiastków metodą ICP-MS","methodology_en":"Determination of selected elements by ICP-MS method","methodology_zh":"ICP-MS法测定选定元素","methodology_cs":"Stanovení vybraných prvků metodou ICP-MS","parameters":[{"name":"Ołów (Pb)","range":""},{"name":"Arsen (As)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Bor (B)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Glin (Al)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Wanad (V)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Żelazo (Fe)","range":""}],"parameters_en":[{"name":"Lead (Pb)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Boron (B)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Iron (Fe)","range":""}],"parameters_zh":[{"name":"铅（Pb）","range":""},{"name":"砷（As）","range":""},{"name":"钼（Mo）","range":""},{"name":"镍（Ni）","range":""},{"name":"铜（Cu）","range":""},{"name":"锰（Mn）","range":""},{"name":"钴（Co）","range":""},{"name":"硼（B）","range":""},{"name":"铍（Be）","range":""},{"name":"铝（Al）","range":""},{"name":"镉（Cd）","range":""},{"name":"锌（Zn）","range":""},{"name":"钒（V）","range":""},{"name":"铬（Cr）","range":""},{"name":"铁（Fe）","range":""}],"parameters_cs":[{"name":"Pb","range":""},{"name":"As","range":""},{"name":"Mo","range":""},{"name":"Ni","range":""},{"name":"Cu","range":""},{"name":"Mn","range":""},{"name":"Co","range":""},{"name":"B","range":""},{"name":"Be","range":""},{"name":"Al","range":""},{"name":"Cd","range":""},{"name":"Zn","range":""},{"name":"V","range":""},{"name":"Cr","range":""},{"name":"Fe","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych pierwiastków metodą ICP-MS\nZakres:\nOłów (Pb)\nArsen (As)\nMolibden (Mo)\nNikiel (Ni)\nMiedź (Cu)\nMangan (Mn)\nKobalt (Co)\nBor (B)\nBeryl (Be)\nGlin (Al)\nKadm (Cd)\nCynk (Zn)\nWanad (V)\nChrom (Cr)\nŻelazo (Fe)","reference":"JPP ÚKZÚZ, 40032.1; JPP ÚKZÚZ, 40224.1","norm_bases":["JPP ÚKZÚZ, 40032.1","JPP ÚKZÚZ, 40224.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie wybranych pierwiastków metodą ICP-MS Ołów (Pb)  Arsen (As)  Molibden (Mo)  Nikiel (Ni)  Miedź (Cu)  Mangan (Mn)  Kobalt (Co)  Bor (B)  Beryl (Be)  Glin (Al)  Kadm (Cd)  Cynk (Zn)  Wanad (V)  Chrom (Cr)  Żelazo (Fe)  Rostlinný materiál Stanovení vybraných prvků metodou ICP-MS Pb  As  Mo  Ni  Cu  Mn  Co  B  Be  Al  Cd  Zn  V  Cr  Fe  JPP ÚKZÚZ, 40032.1; JPP ÚKZÚZ, 40224.1 Material roslinny Oznaczanie wybranych pierwiastkow metoda ICP-MS Olow (Pb)  Arsen (As)  Molibden (Mo)  Nikiel (Ni)  Miedz (Cu)  Mangan (Mn)  Kobalt (Co)  Bor (B)  Beryl (Be)  Glin (Al)  Kadm (Cd)  Cynk (Zn)  Wanad (V)  Chrom (Cr)  Zelazo (Fe)  Rostlinny material Stanoveni vybranych prvku metodou ICP-MS Pb  As  Mo  Ni  Cu  Mn  Co  B  Be  Al  Cd  Zn  V  Cr  Fe  JPP UKZUZ, 40032.1; JPP UKZUZ, 40224.1","search_en":"Plant material Determination of selected elements by ICP-MS method Lead (Pb)  Arsenic (As)  Molybdenum (Mo)  Nickel (Ni)  Copper (Cu)  Manganese (Mn)  Cobalt (Co)  Boron (B)  Beryllium (Be)  Aluminium (Al)  Cadmium (Cd)  Zinc (Zn)  Vanadium (V)  Chromium (Cr)  Iron (Fe)  JPP ÚKZÚZ, 40032.1; JPP ÚKZÚZ, 40224.1","search_zh":"植物材料 ICP-MS法测定选定元素 铅（Pb）  砷（As）  钼（Mo）  镍（Ni）  铜（Cu）  锰（Mn）  钴（Co）  硼（B）  铍（Be）  铝（Al）  镉（Cd）  锌（Zn）  钒（V）  铬（Cr）  铁（Fe）  JPP ÚKZÚZ, 40032.1; JPP ÚKZÚZ, 40224.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":92,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c04d3886d3adcb1c9c8ad104","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"43","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie wybranych pierwiastków metodą ICP-MS","methodology_en":"Determination of selected elements by ICP-MS method","methodology_zh":"ICP-MS法测定选定元素","methodology_cs":"Stanovení vybraných prvků metodou ICP-MS","parameters":[{"name":"Kadm (Cd)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Arsen (As)","range":""},{"name":"Selen (Se)","range":""},{"name":"Jod (I)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Nikiel (Ni)","range":""}],"parameters_en":[{"name":"Cadmium (Cd)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Iodine (I)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Nickel (Ni)","range":""}],"parameters_zh":[{"name":"镉（Cd）","range":""},{"name":"铅（Pb）","range":""},{"name":"铬（Cr）","range":""},{"name":"砷（As）","range":""},{"name":"硒（Se）","range":""},{"name":"碘（I）","range":""},{"name":"钴（Co）","range":""},{"name":"镍（Ni）","range":""}],"parameters_cs":[{"name":"Cd","range":""},{"name":"Pb","range":""},{"name":"Cr","range":""},{"name":"As","range":""},{"name":"Se","range":""},{"name":"I","range":""},{"name":"Co","range":""},{"name":"Ni","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych pierwiastków metodą ICP-MS\nZakres:\nKadm (Cd)\nOłów (Pb)\nChrom (Cr)\nArsen (As)\nSelen (Se)\nJod (I)\nKobalt (Co)\nNikiel (Ni)","reference":"JPP ÚKZÚZ, 10290.1; JPP ÚKZÚZ, 10300.1; JPP ÚKZÚZ, 10410.1; JPP ÚKZÚZ, 10440.1; JPP ÚKZÚZ, 10470.1; JPP ÚKZÚZ, 10412.1; JPP ÚKZÚZ, 10472.1","norm_bases":["JPP ÚKZÚZ, 10290.1","JPP ÚKZÚZ, 10300.1","JPP ÚKZÚZ, 10410.1","JPP ÚKZÚZ, 10440.1","JPP ÚKZÚZ, 10470.1","JPP ÚKZÚZ, 10412.1","JPP ÚKZÚZ, 10472.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie wybranych pierwiastków metodą ICP-MS Kadm (Cd)  Ołów (Pb)  Chrom (Cr)  Arsen (As)  Selen (Se)  Jod (I)  Kobalt (Co)  Nikiel (Ni)  Krmiva a suroviny pro jejich výrobu Stanovení vybraných prvků metodou ICP-MS Cd  Pb  Cr  As  Se  I  Co  Ni  JPP ÚKZÚZ, 10290.1; JPP ÚKZÚZ, 10300.1; JPP ÚKZÚZ, 10410.1; JPP ÚKZÚZ, 10440.1; JPP ÚKZÚZ, 10470.1; JPP ÚKZÚZ, 10412.1; JPP ÚKZÚZ, 10472.1 Pasze i surowce do ich produkcji Oznaczanie wybranych pierwiastkow metoda ICP-MS Kadm (Cd)  Olow (Pb)  Chrom (Cr)  Arsen (As)  Selen (Se)  Jod (I)  Kobalt (Co)  Nikiel (Ni)  Krmiva a suroviny pro jejich vyrobu Stanoveni vybranych prvku metodou ICP-MS Cd  Pb  Cr  As  Se  I  Co  Ni  JPP UKZUZ, 10290.1; JPP UKZUZ, 10300.1; JPP UKZUZ, 10410.1; JPP UKZUZ, 10440.1; JPP UKZUZ, 10470.1; JPP UKZUZ, 10412.1; JPP UKZUZ, 10472.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of selected elements by ICP-MS method Cadmium (Cd)  Lead (Pb)  Chromium (Cr)  Arsenic (As)  Selenium (Se)  Iodine (I)  Cobalt (Co)  Nickel (Ni)  JPP ÚKZÚZ, 10290.1; JPP ÚKZÚZ, 10300.1; JPP ÚKZÚZ, 10410.1; JPP ÚKZÚZ, 10440.1; JPP ÚKZÚZ, 10470.1; JPP ÚKZÚZ, 10412.1; JPP ÚKZÚZ, 10472.1","search_zh":"饲料及其生产原料 ICP-MS法测定选定元素 镉（Cd）  铅（Pb）  铬（Cr）  砷（As）  硒（Se）  碘（I）  钴（Co）  镍（Ni）  JPP ÚKZÚZ, 10290.1; JPP ÚKZÚZ, 10300.1; JPP ÚKZÚZ, 10410.1; JPP ÚKZÚZ, 10440.1; JPP ÚKZÚZ, 10470.1; JPP ÚKZÚZ, 10412.1; JPP ÚKZÚZ, 10472.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":93,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eec7e9af7ec07b7ba46decc1","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"44","test_object":"Glicerol","test_object_en":"Glycerol","test_object_zh":"甘油","test_object_cs":"Glycerol","methodology":"Oznaczanie zawartości metanolu w glicerolu metodą HS-GC/FID","methodology_en":"Determination of methanol in glycerol by HS-GC/FID method","methodology_zh":"HS-GC/FID法测定甘油中甲醇含量","methodology_cs":"Stanovení obsahu metanolu v glycerolu metodou HS-GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości metanolu w glicerolu metodą HS-GC/FID","reference":"JPP ÚKZÚZ, 10520.1","norm_bases":["JPP ÚKZÚZ, 10520.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Glicerol Oznaczanie zawartości metanolu w glicerolu metodą HS-GC/FID Glycerol Stanovení obsahu metanolu v glycerolu metodou HS-GC/FID JPP ÚKZÚZ, 10520.1 Glicerol Oznaczanie zawartosci metanolu w glicerolu metoda HS-GC/FID Glycerol Stanoveni obsahu metanolu v glycerolu metodou HS-GC/FID JPP UKZUZ, 10520.1","search_en":"Glycerol Determination of methanol in glycerol by HS-GC/FID method JPP ÚKZÚZ, 10520.1","search_zh":"甘油 HS-GC/FID法测定甘油中甲醇含量 JPP ÚKZÚZ, 10520.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":94,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3d3fe82ce87b74236903ccfc","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"45","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości wybranych polibromowanych difenyloeterów metodą GC-MS/MS","methodology_en":"Determination of selected polybrominated diphenyl ethers by GC-MS/MS method","methodology_zh":"GC-MS/MS法测定选定多溴联苯醚含量","methodology_cs":"Stanovení obsahu vybraných polybromovaných difenyletherů metodou GC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych polibromowanych difenyloeterów metodą GC-MS/MS","reference":"JPP ÚKZÚZ, 30691.1","norm_bases":["JPP ÚKZÚZ, 30691.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Oznaczane anality: PBDE 28, 47, 66, 85, 99, 100, 153, 154, 183","note_en":"Determined analytes: PBDE 28, 47, 66, 85, 99, 100, 153, 154, 183","note_zh":"测定分析物：PBDE 28, 47, 66, 85, 99, 100, 153, 154, 183","note_cs":"Stanovované analyty: PBDE 28, 47, 66, 85, 99, 100, 153, 154, 183","search_text":"Gleby, osady, osady denne Oznaczanie zawartości wybranych polibromowanych difenyloeterów metodą GC-MS/MS Půdy, kaly, sedimenty Stanovení obsahu vybraných polybromovaných difenyletherů metodou GC-MS/MS JPP ÚKZÚZ, 30691.1 Gleby, osady, osady denne Oznaczanie zawartosci wybranych polibromowanych difenyloeterow metoda GC-MS/MS Pudy, kaly, sedimenty Stanoveni obsahu vybranych polybromovanych difenyletheru metodou GC-MS/MS JPP UKZUZ, 30691.1","search_en":"Soil, sludge, sediments Determination of selected polybrominated diphenyl ethers by GC-MS/MS method JPP ÚKZÚZ, 30691.1","search_zh":"土壤、污泥、沉积物 GC-MS/MS法测定选定多溴联苯醚含量 JPP ÚKZÚZ, 30691.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":95,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5b8c193d9bf76157b44faf81","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"46","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości melaminy i kwasu cyjanurowego metodą LC-MS/MS","methodology_en":"Determination of melamine and cyanuric acid by LC-MS/MS method","methodology_zh":"LC-MS/MS法测定三聚氰胺和三聚氰酸含量","methodology_cs":"Stanovení obsahu melaminu a kyseliny kyanurové metodou LC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości melaminy i kwasu cyjanurowego metodą LC-MS/MS","reference":"JPP ÚKZÚZ, 10530.2","norm_bases":["JPP ÚKZÚZ, 10530.2"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości melaminy i kwasu cyjanurowego metodą LC-MS/MS Krmiva a suroviny pro jejich výrobu Stanovení obsahu melaminu a kyseliny kyanurové metodou LC-MS/MS JPP ÚKZÚZ, 10530.2 Pasze i surowce do ich produkcji Oznaczanie zawartosci melaminy i kwasu cyjanurowego metoda LC-MS/MS Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu melaminu a kyseliny kyanurove metodou LC-MS/MS JPP UKZUZ, 10530.2","search_en":"Animal feeding stuffs and raw materials for their production Determination of melamine and cyanuric acid by LC-MS/MS method JPP ÚKZÚZ, 10530.2","search_zh":"饲料及其生产原料 LC-MS/MS法测定三聚氰胺和三聚氰酸含量 JPP ÚKZÚZ, 10530.2","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":96,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"15f4241049a745702d04a0dd","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"47","test_object":"Glicerol surowy","test_object_en":"Raw glycerol","test_object_zh":"粗甘油","test_object_cs":"Surový glycerol","methodology":"Oznaczanie zawartości glicerolu miareczkowo","methodology_en":"Determination of glycerol by titrimetric method","methodology_zh":"滴定法测定甘油含量","methodology_cs":"Stanovení obsahu glycerolu titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości glicerolu miareczkowo","reference":"JPP ÚKZÚZ, 10200.1","norm_bases":["JPP ÚKZÚZ, 10200.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Glicerol surowy Oznaczanie zawartości glicerolu miareczkowo Surový glycerol Stanovení obsahu glycerolu titračně JPP ÚKZÚZ, 10200.1 Glicerol surowy Oznaczanie zawartosci glicerolu miareczkowo Surovy glycerol Stanoveni obsahu glycerolu titracne JPP UKZUZ, 10200.1","search_en":"Raw glycerol Determination of glycerol by titrimetric method JPP ÚKZÚZ, 10200.1","search_zh":"粗甘油 滴定法测定甘油含量 JPP ÚKZÚZ, 10200.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":97,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"86ed212cae8c915da0ed0736","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"48","test_object":"Glicerol surowy","test_object_en":"Raw glycerol","test_object_zh":"粗甘油","test_object_cs":"Surový glycerol","methodology":"Oznaczanie zawartości wody w glicerolu miareczkowo","methodology_en":"Determination of water in glycerol by titrimetric method","methodology_zh":"滴定法测定甘油中水分含量","methodology_cs":"Stanovení obsahu vody v glycerolu titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wody w glicerolu miareczkowo","reference":"JPP ÚKZÚZ, 10220.1","norm_bases":["JPP ÚKZÚZ, 10220.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Glicerol surowy Oznaczanie zawartości wody w glicerolu miareczkowo Surový glycerol Stanovení obsahu vody v glycerolu titračně JPP ÚKZÚZ, 10220.1 Glicerol surowy Oznaczanie zawartosci wody w glicerolu miareczkowo Surovy glycerol Stanoveni obsahu vody v glycerolu titracne JPP UKZUZ, 10220.1","search_en":"Raw glycerol Determination of water in glycerol by titrimetric method JPP ÚKZÚZ, 10220.1","search_zh":"粗甘油 滴定法测定甘油中水分含量 JPP ÚKZÚZ, 10220.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":98,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9bf03dc55b2d45e3c463ee4c","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"49","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości witaminy D metodą LC-MS/MS","methodology_en":"Determination of vitamin D by LC-MS/MS method","methodology_zh":"LC-MS/MS法测定维生素D含量","methodology_cs":"Stanovení obsahu vitaminu D metodou LC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości witaminy D metodą LC-MS/MS","reference":"JPP ÚKZÚZ, 10271.1","norm_bases":["JPP ÚKZÚZ, 10271.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości witaminy D metodą LC-MS/MS Krmiva a suroviny pro jejich výrobu Stanovení obsahu vitaminu D metodou LC-MS/MS JPP ÚKZÚZ, 10271.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci witaminy D metoda LC-MS/MS Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vitaminu D metodou LC-MS/MS JPP UKZUZ, 10271.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of vitamin D by LC-MS/MS method JPP ÚKZÚZ, 10271.1","search_zh":"饲料及其生产原料 LC-MS/MS法测定维生素D含量 JPP ÚKZÚZ, 10271.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":99,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0fff352298d0e48b3bfde807","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"50","test_object":"Pasze i surowce do ich produkcji, materiał roślinny","test_object_en":"Animal feeding stuffs and raw materials for their production, plant material","test_object_zh":"饲料及其生产原料、植物材料","test_object_cs":"Krmiva a suroviny pro jejich výrobu, rostlinný materiál","methodology":"Oznaczanie zawartości wybranych pozostałości pestycydów polarnych metodą LC-MS/MS","methodology_en":"Determination of selected polar residues of pesticides by LC-MS/MS method","methodology_zh":"LC-MS/MS法测定选定极性农药残留含量","methodology_cs":"Stanovení obsahu vybraných reziduí polárních pesticidů metodou LC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pozostałości pestycydów polarnych metodą LC-MS/MS","reference":"JPP ÚKZÚZ, 10605.4; JPP ÚKZÚZ, 10606.1","norm_bases":["JPP ÚKZÚZ, 10605.4","JPP ÚKZÚZ, 10606.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Oznaczane anality: chlorek chlormekwatu, chlorek mepikwatu, glifosat, N-acetyloglifosat, glufosynat, kwas aminometylofosfonowy (AMPA), N-acetyloglufosynat (NAG), fosetyl-Al, etefon, kwas 3-[hydroksy(metylo)fosfinoilo]propionowy (MPP), suma glufosynatu (suma izomerów glufosynatu, jego soli i metabolitów MPP i NAG, wyrażona jako glufosynat)","note_en":"Determined analytes: chlormequat chloride, mepiquat chloride, glyphosate, N-acetyl-glyphosate, glufosinate, aminomethylphosphonic acid (AMPA), N-acetyl-glufosinate (NAG), fosetyl-Al, ethephon, 3-methylphosphinicopropionic acid (MPP), glufosinate sum (sum of glufosinate isomers, its salts and its metabolites MPP and NAG, expressed as glufosinate)","note_zh":"测定分析物：矮壮素, 缩节胺, 草甘膦, N-乙酰草甘膦, 草铵膦, 氨甲基膦酸（AMPA）, N-乙酰草铵膦（NAG）, 三乙膦酸铝, 乙烯利, 3-甲基膦酰基丙酸（MPP）, 草铵膦总量（草铵膦异构体、其盐及代谢物MPP和NAG之和，以草铵膦计）","note_cs":"Stanovované analyty: chlormekvát chlorid, mepikvát chlorid, glyfosát, N-acetyl-glyfosát, glufosinát, aminomethylfosfonová kyselina (AMPA), N-acetyl-glufosinát (NAG), fosetyl-Al, ethefon, 3-[hydroxy(methyl)fosfinoyl] propionová kyselina (MPP), glufosinát suma (suma izomerů glufosinátu, jeho solí a jeho metabolitů MPP a NAG, vyjádřena jako glufosinát)","search_text":"Pasze i surowce do ich produkcji, materiał roślinny Oznaczanie zawartości wybranych pozostałości pestycydów polarnych metodą LC-MS/MS Krmiva a suroviny pro jejich výrobu, rostlinný materiál Stanovení obsahu vybraných reziduí polárních pesticidů metodou LC-MS/MS JPP ÚKZÚZ, 10605.4; JPP ÚKZÚZ, 10606.1 Pasze i surowce do ich produkcji, material roslinny Oznaczanie zawartosci wybranych pozostalosci pestycydow polarnych metoda LC-MS/MS Krmiva a suroviny pro jejich vyrobu, rostlinny material Stanoveni obsahu vybranych rezidui polarnich pesticidu metodou LC-MS/MS JPP UKZUZ, 10605.4; JPP UKZUZ, 10606.1","search_en":"Animal feeding stuffs and raw materials for their production, plant material Determination of selected polar residues of pesticides by LC-MS/MS method JPP ÚKZÚZ, 10605.4; JPP ÚKZÚZ, 10606.1","search_zh":"饲料及其生产原料、植物材料 LC-MS/MS法测定选定极性农药残留含量 JPP ÚKZÚZ, 10605.4; JPP ÚKZÚZ, 10606.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":100,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"04b0b453daa42e5e73fe547e","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"51","test_object":"Pasze i surowce do ich produkcji, materiał roślinny","test_object_en":"Animal feeding stuffs and raw materials for their production, plant material","test_object_zh":"饲料及其生产原料、植物材料","test_object_cs":"Krmiva a suroviny pro jejich výrobu, rostlinný materiál","methodology":"Wielopozostałościowa metoda oznaczania wybranych mikotoksyn metodą LC-MS/MS","methodology_en":"Multiresidual method for determination of selected mycotoxins by LC-MS/MS method","methodology_zh":"LC-MS/MS多残留法测定选定霉菌毒素","methodology_cs":"Multireziduální metoda stanovení vybraných mykotoxinů metodou LC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wielopozostałościowa metoda oznaczania wybranych mikotoksyn metodą LC-MS/MS","reference":"JPP ÚKZÚZ, 10575.1","norm_bases":["JPP ÚKZÚZ, 10575.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Oznaczane anality: aflatoksyna B1, B2, G1, G2, toksyna T-2, deoksyniwalenol, ochratoksyna A, enniatyna A, A1, B, B1, fumonizyna B1, fumonizyna B2, bowerycyna, zearalenon, toksyna HT-2","note_en":"Determined analytes: Aflatoxin B1, B2, G1, G2, T-2 toxin, deoxynivalenol, ochratoxin A, enniatin A, A1, B, B1, fumonisin B1, fumonisin B2, beauvericin, zearalenone, HT-2 toxin","note_zh":"测定分析物：黄曲霉毒素B1、B2、G1、G2, T-2毒素, 脱氧雪腐镰刀菌烯醇, 赭曲霉毒素A, 恩镰孢菌素A、A1、B、B1, 伏马毒素B1, 伏马毒素B2, 白僵菌素, 玉米赤霉烯酮, HT-2毒素","note_cs":"Stanovované analyty: Aflatoxin B1, B2, G1, G2, T-2 toxin, deoxynilvalenol, ochratoxin A, enniatin A, A1, B, B1, fumonisin B1, fumonisin B2, beauvericin, zearalenon, HT-2 toxin","search_text":"Pasze i surowce do ich produkcji, materiał roślinny Wielopozostałościowa metoda oznaczania wybranych mikotoksyn metodą LC-MS/MS Krmiva a suroviny pro jejich výrobu, rostlinný materiál Multireziduální metoda stanovení vybraných mykotoxinů metodou LC-MS/MS JPP ÚKZÚZ, 10575.1 Pasze i surowce do ich produkcji, material roslinny Wielopozostalosciowa metoda oznaczania wybranych mikotoksyn metoda LC-MS/MS Krmiva a suroviny pro jejich vyrobu, rostlinny material Multirezidualni metoda stanoveni vybranych mykotoxinu metodou LC-MS/MS JPP UKZUZ, 10575.1","search_en":"Animal feeding stuffs and raw materials for their production, plant material Multiresidual method for determination of selected mycotoxins by LC-MS/MS method JPP ÚKZÚZ, 10575.1","search_zh":"饲料及其生产原料、植物材料 LC-MS/MS多残留法测定选定霉菌毒素 JPP ÚKZÚZ, 10575.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":101,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3d0d07921af72b41a64f664b","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"52","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie toksyn naturalnych metodą LC-MS/MS","methodology_en":"Determination of natural toxins by LC-MS/MS method","methodology_zh":"LC-MS/MS法测定天然毒素","methodology_cs":"Stanovení přírodních toxinů metodou LC-MS/MS","parameters":[{"name":"Ergokornina","range":""},{"name":"ergokorninina","range":""},{"name":"ergozyna","range":""},{"name":"ergozynina","range":""},{"name":"ergokrystyna","range":""},{"name":"ergokrystynina","range":""},{"name":"ergokryptyna","range":""},{"name":"ergokryptynina","range":""},{"name":"ergotamina","range":""},{"name":"ergotaminina","range":""},{"name":"ergometryna","range":""},{"name":"ergometrynina","range":""},{"name":"retrorsyna","range":""},{"name":"monokrotalina","range":""},{"name":"senecjonina","range":""},{"name":"senecyfilina","range":""},{"name":"senkirkina","range":""}],"parameters_en":[{"name":"Ergocornine","range":""},{"name":"ergocorninine","range":""},{"name":"ergosine","range":""},{"name":"ergosinine","range":""},{"name":"ergocrystine","range":""},{"name":"ergocrystinine","range":""},{"name":"ergocryptine","range":""},{"name":"ergocryptinine","range":""},{"name":"ergotamine","range":""},{"name":"ergotaminine","range":""},{"name":"ergometrine","range":""},{"name":"ergometrinine","range":""},{"name":"retrosine","range":""},{"name":"monokrotaline","range":""},{"name":"senecionine","range":""},{"name":"senecifiline","range":""},{"name":"senkirkine","range":""}],"parameters_zh":[{"name":"麦角柯宁碱","range":""},{"name":"麦角柯宁宁碱","range":""},{"name":"麦角新生碱","range":""},{"name":"麦角新宁碱","range":""},{"name":"麦角克碱","range":""},{"name":"麦角克宁碱","range":""},{"name":"麦角隐亭","range":""},{"name":"麦角隐宁","range":""},{"name":"麦角胺","range":""},{"name":"麦角胺宁","range":""},{"name":"麦角新碱","range":""},{"name":"麦角新宁","range":""},{"name":"倒千里光碱","range":""},{"name":"野百合碱","range":""},{"name":"千里光宁碱","range":""},{"name":"千里光菲灵碱","range":""},{"name":"克氏千里光碱","range":""}],"parameters_cs":[{"name":"Ergocornin","range":""},{"name":"ergocorninin","range":""},{"name":"ergosin","range":""},{"name":"ergosinin","range":""},{"name":"ergocrystin","range":""},{"name":"ergocrystinin","range":""},{"name":"ergocryptin","range":""},{"name":"ergocryptinin","range":""},{"name":"ergotamin","range":""},{"name":"ergotaminin","range":""},{"name":"ergometrin","range":""},{"name":"ergometrinin","range":""},{"name":"retrosin","range":""},{"name":"monokrotalin","range":""},{"name":"senecionin","range":""},{"name":"senecifilin","range":""},{"name":"senkirkin","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie toksyn naturalnych metodą LC-MS/MS\nZakres:\nErgokornina\nergokorninina\nergozyna\nergozynina\nergokrystyna\nergokrystynina\nergokryptyna\nergokryptynina\nergotamina\nergotaminina\nergometryna\nergometrynina\nretrorsyna\nmonokrotalina\nsenecjonina\nsenecyfilina\nsenkirkina","reference":"JPP ÚKZÚZ, 10576.1","norm_bases":["JPP ÚKZÚZ, 10576.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie toksyn naturalnych metodą LC-MS/MS Ergokornina  ergokorninina  ergozyna  ergozynina  ergokrystyna  ergokrystynina  ergokryptyna  ergokryptynina  ergotamina  ergotaminina  ergometryna  ergometrynina  retrorsyna  monokrotalina  senecjonina  senecyfilina  senkirkina  Krmiva a suroviny pro jejich výrobu Stanovení přírodních toxinů metodou LC-MS/MS Ergocornin  ergocorninin  ergosin  ergosinin  ergocrystin  ergocrystinin  ergocryptin  ergocryptinin  ergotamin  ergotaminin  ergometrin  ergometrinin  retrosin  monokrotalin  senecionin  senecifilin  senkirkin  JPP ÚKZÚZ, 10576.1 Pasze i surowce do ich produkcji Oznaczanie toksyn naturalnych metoda LC-MS/MS Ergokornina  ergokorninina  ergozyna  ergozynina  ergokrystyna  ergokrystynina  ergokryptyna  ergokryptynina  ergotamina  ergotaminina  ergometryna  ergometrynina  retrorsyna  monokrotalina  senecjonina  senecyfilina  senkirkina  Krmiva a suroviny pro jejich vyrobu Stanoveni prirodnich toxinu metodou LC-MS/MS Ergocornin  ergocorninin  ergosin  ergosinin  ergocrystin  ergocrystinin  ergocryptin  ergocryptinin  ergotamin  ergotaminin  ergometrin  ergometrinin  retrosin  monokrotalin  senecionin  senecifilin  senkirkin  JPP UKZUZ, 10576.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of natural toxins by LC-MS/MS method Ergocornine  ergocorninine  ergosine  ergosinine  ergocrystine  ergocrystinine  ergocryptine  ergocryptinine  ergotamine  ergotaminine  ergometrine  ergometrinine  retrosine  monokrotaline  senecionine  senecifiline  senkirkine  JPP ÚKZÚZ, 10576.1","search_zh":"饲料及其生产原料 LC-MS/MS法测定天然毒素 麦角柯宁碱  麦角柯宁宁碱  麦角新生碱  麦角新宁碱  麦角克碱  麦角克宁碱  麦角隐亭  麦角隐宁  麦角胺  麦角胺宁  麦角新碱  麦角新宁  倒千里光碱  野百合碱  千里光宁碱  千里光菲灵碱  克氏千里光碱  JPP ÚKZÚZ, 10576.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":102,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"af4ab890cfaf3dcc82d5f4b7","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"53","test_object":"Pasze i surowce do ich produkcji, materiał roślinny","test_object_en":"Animal feeding stuffs and raw materials for their production, plant material","test_object_zh":"饲料及其生产原料、植物材料","test_object_cs":"Krmiva a suroviny pro jejich výrobu, rostlinný materiál","methodology":"Oznaczanie zawartości pozostałości ditiokarbaminianów metodą GC-MS/MS oznaczanych pośrednio jako CS2","methodology_en":"Determination of residues of dithiocarbamates by GC-MS/MS method determined indirectly as CS2","methodology_zh":"GC-MS/MS法以CS2间接测定二硫代氨基甲酸酯残留","methodology_cs":"Stanovení obsahu reziduí dithiokarbamátů metodou GC-MS/MS stanovených nepřímo jako CS2","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości pozostałości ditiokarbaminianów metodą GC-MS/MS oznaczanych pośrednio jako CS2","reference":"JPP ÚKZÚZ, 10615.1","norm_bases":["JPP ÚKZÚZ, 10615.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji, materiał roślinny Oznaczanie zawartości pozostałości ditiokarbaminianów metodą GC-MS/MS oznaczanych pośrednio jako CS2 Krmiva a suroviny pro jejich výrobu, rostlinný materiál Stanovení obsahu reziduí dithiokarbamátů metodou GC-MS/MS stanovených nepřímo jako CS2 JPP ÚKZÚZ, 10615.1 Pasze i surowce do ich produkcji, material roslinny Oznaczanie zawartosci pozostalosci ditiokarbaminianow metoda GC-MS/MS oznaczanych posrednio jako CS2 Krmiva a suroviny pro jejich vyrobu, rostlinny material Stanoveni obsahu rezidui dithiokarbamatu metodou GC-MS/MS stanovenych neprimo jako CS2 JPP UKZUZ, 10615.1","search_en":"Animal feeding stuffs and raw materials for their production, plant material Determination of residues of dithiocarbamates by GC-MS/MS method determined indirectly as CS2 JPP ÚKZÚZ, 10615.1","search_zh":"饲料及其生产原料、植物材料 GC-MS/MS法以CS2间接测定二硫代氨基甲酸酯残留 JPP ÚKZÚZ, 10615.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":103,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ebc3d3889ad9a9de98e03ad0","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"54","test_object":"Makowiny","test_object_en":"Poppy capsules","test_object_zh":"罂粟壳","test_object_cs":"Makovina","methodology":"Oznaczanie wybranych alkaloidów opium metodą HPLC/DAD","methodology_en":"Determination of selected opium alkaloids by HPLC/DAD method","methodology_zh":"HPLC/DAD法测定选定鸦片生物碱","methodology_cs":"Stanovení vybraných opiových alkaloidů metodou HPLC/DAD","parameters":[{"name":"Morfina","range":""}],"parameters_en":[{"name":"Morphine","range":""}],"parameters_zh":[{"name":"吗啡","range":""}],"parameters_cs":[{"name":"Morfin","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych alkaloidów opium metodą HPLC/DAD\nMorfina","reference":"JPP ÚKZÚZ, 50250.1","norm_bases":["JPP ÚKZÚZ, 50250.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Makowiny Oznaczanie wybranych alkaloidów opium metodą HPLC/DAD Morfina  Makovina Stanovení vybraných opiových alkaloidů metodou HPLC/DAD Morfin  JPP ÚKZÚZ, 50250.1 Makowiny Oznaczanie wybranych alkaloidow opium metoda HPLC/DAD Morfina  Makovina Stanoveni vybranych opiovych alkaloidu metodou HPLC/DAD Morfin  JPP UKZUZ, 50250.1","search_en":"Poppy capsules Determination of selected opium alkaloids by HPLC/DAD method Morphine  JPP ÚKZÚZ, 50250.1","search_zh":"罂粟壳 HPLC/DAD法测定选定鸦片生物碱 吗啡  JPP ÚKZÚZ, 50250.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":104,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bf6f491f7039399b2a4ee468","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"55","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości fluorków metodą ISE","methodology_en":"Determination of fluorides by ISE method","methodology_zh":"离子选择电极法测定氟化物含量","methodology_cs":"Stanovení obsahu fluoridů metodou ISE","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości fluorków metodą ISE","reference":"JPP ÚKZÚZ, 10500.1","norm_bases":["JPP ÚKZÚZ, 10500.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości fluorków metodą ISE Krmiva a suroviny pro jejich výrobu Stanovení obsahu fluoridů metodou ISE JPP ÚKZÚZ, 10500.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci fluorkow metoda ISE Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu fluoridu metodou ISE JPP UKZUZ, 10500.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of fluorides by ISE method JPP ÚKZÚZ, 10500.1","search_zh":"饲料及其生产原料 离子选择电极法测定氟化物含量 JPP ÚKZÚZ, 10500.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":105,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1cbfdeb669f82990ec475bc5","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"56","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości mocznika metodą spektrofotometryczną","methodology_en":"Determination of urea by spectrophotometric method","methodology_zh":"分光光度法测定尿素含量","methodology_cs":"Stanovení obsahu močoviny spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości mocznika metodą spektrofotometryczną","reference":"JPP ÚKZÚZ, 10012.1","norm_bases":["JPP ÚKZÚZ, 10012.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości mocznika metodą spektrofotometryczną Krmiva a suroviny pro jejich výrobu Stanovení obsahu močoviny spektrofotometricky JPP ÚKZÚZ, 10012.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci mocznika metoda spektrofotometryczna Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu mocoviny spektrofotometricky JPP UKZUZ, 10012.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of urea by spectrophotometric method JPP ÚKZÚZ, 10012.1","search_zh":"饲料及其生产原料 分光光度法测定尿素含量 JPP ÚKZÚZ, 10012.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":106,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"73383acf6e14df3d309eee10","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"57","test_object":"Gleby, osady denne","test_object_en":"Soil, sediments","test_object_zh":"土壤、沉积物","test_object_cs":"Půdy, sedimenty","methodology":"Oznaczanie zawartości węglowodorów C10–C40 metodą GC/FID","methodology_en":"Determination of hydrocarbons C10 – C40 content by GC/FID method","methodology_zh":"GC/FID法测定C10-C40烃类含量","methodology_cs":"Stanovení obsahu uhlovodíků C10-C40 metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości węglowodorów C10–C40 metodą GC/FID","reference":"JPP ÚKZÚZ, 30720.1","norm_bases":["JPP ÚKZÚZ, 30720.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Brno","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Brno","lab_section_zh":"ÚKZÚZ, NRL，NRL布尔诺处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Brno","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady denne Oznaczanie zawartości węglowodorów C10–C40 metodą GC/FID Půdy, sedimenty Stanovení obsahu uhlovodíků C10-C40 metodou GC/FID JPP ÚKZÚZ, 30720.1 Gleby, osady denne Oznaczanie zawartosci weglowodorow C10–C40 metoda GC/FID Pudy, sedimenty Stanoveni obsahu uhlovodiku C10-C40 metodou GC/FID JPP UKZUZ, 30720.1","search_en":"Soil, sediments Determination of hydrocarbons C10 – C40 content by GC/FID method JPP ÚKZÚZ, 30720.1","search_zh":"土壤、沉积物 GC/FID法测定C10-C40烃类含量 JPP ÚKZÚZ, 30720.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":107,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7c7d5514e8ca4e87a4b97244","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"1","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP ÚKZÚZ, 10002.1","norm_bases":["JPP ÚKZÚZ, 10002.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Krmiva a suroviny pro jejich výrobu Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP ÚKZÚZ, 10002.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 10002.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of moisture by gravimetric method and calculation of dry matter JPP ÚKZÚZ, 10002.1","search_zh":"饲料及其生产原料 重量法测定水分含量并计算干物质 JPP ÚKZÚZ, 10002.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":108,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5586b935d79b4bfa394adfbc","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"2","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP ÚKZÚZ, 40010.1","norm_bases":["JPP ÚKZÚZ, 40010.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Rostlinný materiál Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP ÚKZÚZ, 40010.1 Material roslinny Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Rostlinny material Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 40010.1","search_en":"Plant material Determination of moisture by gravimetric method and calculation of dry matter JPP ÚKZÚZ, 40010.1","search_zh":"植物材料 重量法测定水分含量并计算干物质 JPP ÚKZÚZ, 40010.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":109,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4f3485144911552a2f0018b7","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"3","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP UKZÚZ, 30020.1","norm_bases":["JPP UKZÚZ, 30020.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Půdy, kaly, sedimenty Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP UKZÚZ, 30020.1 Gleby, osady, osady denne Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Pudy, kaly, sedimenty Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 30020.1","search_en":"Soil, sludge, sediments Determination of moisture by gravimetric method and calculation of dry matter JPP UKZÚZ, 30020.1","search_zh":"土壤、污泥、沉积物 重量法测定水分含量并计算干物质 JPP UKZÚZ, 30020.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":110,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8c46ba48025903ccfc84150c","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"4","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości popiołu metodą wagową","methodology_en":"Determination of ash by gravimetric method","methodology_zh":"重量法测定灰分含量","methodology_cs":"Stanovení obsahu popele gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości popiołu metodą wagową","reference":"JPP ÚKZÚZ, 10004.1","norm_bases":["JPP ÚKZÚZ, 10004.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości popiołu metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu popele gravimetricky JPP ÚKZÚZ, 10004.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci popiolu metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu popele gravimetricky JPP UKZUZ, 10004.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of ash by gravimetric method JPP ÚKZÚZ, 10004.1","search_zh":"饲料及其生产原料 重量法测定灰分含量 JPP ÚKZÚZ, 10004.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":111,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7e26d87834116a679db142f5","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"5","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości substancji organicznych (strata prażenia, substancje palne) metodą wagową","methodology_en":"Determination of organic matter (loss on ignition, combustible substances) by gravimetric method","methodology_zh":"重量法测定有机物含量（灼烧减量、可燃物）","methodology_cs":"Stanovení obsahu organických látek (ztráta žíháním, spalitelné látky) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości substancji organicznych (strata prażenia, substancje palne) metodą wagową","reference":"JPP ÚKZÚZ, 30900.1","norm_bases":["JPP ÚKZÚZ, 30900.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie zawartości substancji organicznych (strata prażenia, substancje palne) metodą wagową Půdy, kaly, sedimenty Stanovení obsahu organických látek (ztráta žíháním, spalitelné látky) gravimetricky JPP ÚKZÚZ, 30900.1 Gleby, osady, osady denne Oznaczanie zawartosci substancji organicznych (strata prazenia, substancje palne) metoda wagowa Pudy, kaly, sedimenty Stanoveni obsahu organickych latek (ztrata zihanim, spalitelne latky) gravimetricky JPP UKZUZ, 30900.1","search_en":"Soil, sludge, sediments Determination of organic matter (loss on ignition, combustible substances) by gravimetric method JPP ÚKZÚZ, 30900.1","search_zh":"土壤、污泥、沉积物 重量法测定有机物含量（灼烧减量、可燃物） JPP ÚKZÚZ, 30900.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":112,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f1613d72c94663fc8e0e0eed","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"6","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości tłuszczu (oleju) metodą wagową","methodology_en":"Determination of fat (oil) by gravimetric method","methodology_zh":"重量法测定脂肪（油）含量","methodology_cs":"Stanovení obsahu tuku (oleje) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości tłuszczu (oleju) metodą wagową","reference":"JPP ÚKZÚZ, 10058.1","norm_bases":["JPP ÚKZÚZ, 10058.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości tłuszczu (oleju) metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu tuku (oleje) gravimetricky JPP ÚKZÚZ, 10058.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci tluszczu (oleju) metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu tuku (oleje) gravimetricky JPP UKZUZ, 10058.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of fat (oil) by gravimetric method JPP ÚKZÚZ, 10058.1","search_zh":"饲料及其生产原料 重量法测定脂肪（油）含量 JPP ÚKZÚZ, 10058.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":113,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0f13fc59de76f85a64254484","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"7","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości tłuszczu (oleju) metodą wagową","methodology_en":"Determination of fat (oil) by gravimetric method","methodology_zh":"重量法测定脂肪（油）含量","methodology_cs":"Stanovení obsahu tuku (oleje) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości tłuszczu (oleju) metodą wagową","reference":"JPP ÚKZÚZ, 10060.1","norm_bases":["JPP ÚKZÚZ, 10060.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości tłuszczu (oleju) metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu tuku (oleje) gravimetricky JPP ÚKZÚZ, 10060.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci tluszczu (oleju) metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu tuku (oleje) gravimetricky JPP UKZUZ, 10060.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of fat (oil) by gravimetric method JPP ÚKZÚZ, 10060.1","search_zh":"饲料及其生产原料 重量法测定脂肪（油）含量 JPP ÚKZÚZ, 10060.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":114,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"39ccada62d3cd90c295d5720","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"8","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości włókna metodą wagową","methodology_en":"Determination of fibre by gravimetric method","methodology_zh":"重量法测定纤维含量","methodology_cs":"Stanovení obsahu vlákniny gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości włókna metodą wagową","reference":"JPP ÚKZÚZ, 10068.1","norm_bases":["JPP ÚKZÚZ, 10068.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości włókna metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu vlákniny gravimetricky JPP ÚKZÚZ, 10068.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wlokna metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vlakniny gravimetricky JPP UKZUZ, 10068.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of fibre by gravimetric method JPP ÚKZÚZ, 10068.1","search_zh":"饲料及其生产原料 重量法测定纤维含量 JPP ÚKZÚZ, 10068.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":115,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5f7bddcb0683414d20eea481","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"9","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości skrobi metodą polarymetryczną","methodology_en":"Determination of starch by polarimetric method","methodology_zh":"旋光法测定淀粉含量","methodology_cs":"Stanovení obsahu škrobu polarimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości skrobi metodą polarymetryczną","reference":"JPP ÚKZÚZ, 10083.1","norm_bases":["JPP ÚKZÚZ, 10083.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości skrobi metodą polarymetryczną Krmiva a suroviny pro jejich výrobu Stanovení obsahu škrobu polarimetricky JPP ÚKZÚZ, 10083.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci skrobi metoda polarymetryczna Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu skrobu polarimetricky JPP UKZUZ, 10083.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of starch by polarimetric method JPP ÚKZÚZ, 10083.1","search_zh":"饲料及其生产原料 旋光法测定淀粉含量 JPP ÚKZÚZ, 10083.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":116,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c0be64f215162012fdb5595d","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"10","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości cukrów miareczkowo","methodology_en":"Determination of sugars by titrimetric method","methodology_zh":"滴定法测定糖含量","methodology_cs":"Stanovení obsahu cukrů titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości cukrów miareczkowo","reference":"JPP ÚKZÚZ, 10084.1","norm_bases":["JPP ÚKZÚZ, 10084.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości cukrów miareczkowo Krmiva a suroviny pro jejich výrobu Stanovení obsahu cukrů titračně JPP ÚKZÚZ, 10084.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci cukrow miareczkowo Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu cukru titracne JPP UKZUZ, 10084.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of sugars by titrimetric method JPP ÚKZÚZ, 10084.1","search_zh":"饲料及其生产原料 滴定法测定糖含量 JPP ÚKZÚZ, 10084.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":117,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"082d4fda799608ab2fe6589f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"11","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości azotu miareczkowo i substancji azotowych obliczeniowo z wyników pomiarów","methodology_en":"Determination of the content of nitrogen by titrimetric method and nitrogenous substances by calculation from measured values","methodology_zh":"滴定法测定氮含量并由测量值计算含氮物质","methodology_cs":"Stanovení obsahu dusíku titračně a dusíkatých látek výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu miareczkowo i substancji azotowych obliczeniowo z wyników pomiarów","reference":"JPP ÚKZÚZ, 10014.1","norm_bases":["JPP ÚKZÚZ, 10014.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości azotu miareczkowo i substancji azotowych obliczeniowo z wyników pomiarów Krmiva a suroviny pro jejich výrobu Stanovení obsahu dusíku titračně a dusíkatých látek výpočtem z naměřených hodnot JPP ÚKZÚZ, 10014.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci azotu miareczkowo i substancji azotowych obliczeniowo z wynikow pomiarow Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu dusiku titracne a dusikatych latek vypoctem z namerenych hodnot JPP UKZUZ, 10014.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of the content of nitrogen by titrimetric method and nitrogenous substances by calculation from measured values JPP ÚKZÚZ, 10014.1","search_zh":"饲料及其生产原料 滴定法测定氮含量并由测量值计算含氮物质 JPP ÚKZÚZ, 10014.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":118,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"648ca2852efaa6c352273159","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"12","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości azotu miareczkowo","methodology_en":"Determination of nitrogen by titrimetric method","methodology_zh":"滴定法测定氮含量","methodology_cs":"Stanovení obsahu dusíku titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu miareczkowo","reference":"JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40053.1","norm_bases":["JPP ÚKZÚZ, 40018.1","JPP ÚKZÚZ, 40053.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości azotu miareczkowo Rostlinný materiál Stanovení obsahu dusíku titračně JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40053.1 Material roslinny Oznaczanie zawartosci azotu miareczkowo Rostlinny material Stanoveni obsahu dusiku titracne JPP UKZUZ, 40018.1; JPP UKZUZ, 40053.1","search_en":"Plant material Determination of nitrogen by titrimetric method JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40053.1","search_zh":"植物材料 滴定法测定氮含量 JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40053.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":119,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2f145ea956fcfbf622b14410","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"13","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości robenidyny metodą HPLC/UV","methodology_en":"Determination of robenidin by HPLC/UV method","methodology_zh":"HPLC/UV法测定罗贝胍含量","methodology_cs":"Stanovení obsahu robenidinu metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości robenidyny metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10390.1","norm_bases":["JPP ÚKZÚZ, 10390.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości robenidyny metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení obsahu robenidinu metodou HPLC/UV JPP ÚKZÚZ, 10390.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci robenidyny metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu robenidinu metodou HPLC/UV JPP UKZUZ, 10390.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of robenidin by HPLC/UV method JPP ÚKZÚZ, 10390.1","search_zh":"饲料及其生产原料 HPLC/UV法测定罗贝胍含量 JPP ÚKZÚZ, 10390.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":120,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1ae9c673b9607d2b92456076","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"14","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości witaminy A, E metodą HPLC/UV","methodology_en":"Determination of vitamin A, E by HPLC/UV method","methodology_zh":"HPLC/UV法测定维生素A、E含量","methodology_cs":"Stanovení obsahu vitamínu A, E metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości witaminy A, E metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10380.1","norm_bases":["JPP ÚKZÚZ, 10380.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości witaminy A, E metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení obsahu vitamínu A, E metodou HPLC/UV JPP ÚKZÚZ, 10380.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci witaminy A, E metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vitaminu A, E metodou HPLC/UV JPP UKZUZ, 10380.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of vitamin A, E by HPLC/UV method JPP ÚKZÚZ, 10380.1","search_zh":"饲料及其生产原料 HPLC/UV法测定维生素A、E含量 JPP ÚKZÚZ, 10380.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":121,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"44bc93847755838c1bf353ff","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"15","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości fosforu metodą spektrofotometryczną","methodology_en":"Determination of phosphorus by spectrophotometric method","methodology_zh":"分光光度法测定磷含量","methodology_cs":"Stanovení obsahu fosforu spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości fosforu metodą spektrofotometryczną","reference":"JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40060.1","norm_bases":["JPP ÚKZÚZ, 40018.1","JPP ÚKZÚZ, 40060.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości fosforu metodą spektrofotometryczną Rostlinný materiál Stanovení obsahu fosforu spektrofotometricky JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40060.1 Material roslinny Oznaczanie zawartosci fosforu metoda spektrofotometryczna Rostlinny material Stanoveni obsahu fosforu spektrofotometricky JPP UKZUZ, 40018.1; JPP UKZUZ, 40060.1","search_en":"Plant material Determination of phosphorus by spectrophotometric method JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40060.1","search_zh":"植物材料 分光光度法测定磷含量 JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40060.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":122,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"96699fed393876c1ba4400a3","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"16","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wybranych dodatków paszowych metodą HPLC/UV","methodology_en":"Determination of selected feed additives by HPLC/UV method","methodology_zh":"HPLC/UV法测定选定饲料添加剂含量","methodology_cs":"Stanovení obsahu vybraných doplňkových látek metodou HPLC/UV","parameters":[{"name":"Salinomycyna","range":""},{"name":"monenzyna","range":""},{"name":"narazyna","range":""}],"parameters_en":[{"name":"Salinomycin","range":""},{"name":"monensin","range":""},{"name":"narasin","range":""}],"parameters_zh":[{"name":"盐霉素","range":""},{"name":"莫能菌素","range":""},{"name":"甲基盐霉素","range":""}],"parameters_cs":[{"name":"Salinomycin","range":""},{"name":"monensin","range":""},{"name":"narasin","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych dodatków paszowych metodą HPLC/UV\nZakres:\nSalinomycyna\nmonenzyna\nnarazyna","reference":"JPP ÚKZÚZ, 10350.1","norm_bases":["JPP ÚKZÚZ, 10350.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wybranych dodatków paszowych metodą HPLC/UV Salinomycyna  monenzyna  narazyna  Krmiva a suroviny pro jejich výrobu Stanovení obsahu vybraných doplňkových látek metodou HPLC/UV Salinomycin  monensin  narasin  JPP ÚKZÚZ, 10350.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wybranych dodatkow paszowych metoda HPLC/UV Salinomycyna  monenzyna  narazyna  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vybranych doplnkovych latek metodou HPLC/UV Salinomycin  monensin  narasin  JPP UKZUZ, 10350.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of selected feed additives by HPLC/UV method Salinomycin  monensin  narasin  JPP ÚKZÚZ, 10350.1","search_zh":"饲料及其生产原料 HPLC/UV法测定选定饲料添加剂含量 盐霉素  莫能菌素  甲基盐霉素  JPP ÚKZÚZ, 10350.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":123,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"312556e08a8fb1bc23f507d5","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"17","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości wielopierścieniowych węglowodorów aromatycznych metodą HPLC/UV, FLD","methodology_en":"Determination of polyaromatic hydrocarbons by HPLC/UV, FLD method","methodology_zh":"HPLC/UV、FLD法测定多环芳烃含量","methodology_cs":"Stanovení obsahu polyaromatických uhlovodíků metodou HPLC/UV, FLD","parameters":[{"name":"Naftalen","range":""},{"name":"acenaftylen","range":""},{"name":"acenaften","range":""},{"name":"fluoren","range":""},{"name":"fluoranten","range":""},{"name":"fenantren","range":""},{"name":"antracen","range":""},{"name":"piren","range":""},{"name":"benzo(a)antracen","range":""},{"name":"chryzen","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"benzo(a)piren","range":""},{"name":"dibenzo(a,h)antracen","range":""},{"name":"benzo(ghi)perylen","range":""},{"name":"indeno(1,2,3-cd)piren","range":""},{"name":"benzo(e)piren","range":""},{"name":"perylen","range":""}],"parameters_en":[{"name":"Naphthalene","range":""},{"name":"acenaphthylene","range":""},{"name":"acenaphthene","range":""},{"name":"fluorene","range":""},{"name":"fluoranthene","range":""},{"name":"phenanthrene","range":""},{"name":"anthracene","range":""},{"name":"pyrene","range":""},{"name":"benzo(a)anthracene","range":""},{"name":"chrysene","range":""},{"name":"benzo(b)fluoranthene","range":""},{"name":"benzo(k)fluoranthene","range":""},{"name":"benzo(a)pyrene","range":""},{"name":"dibenzo(a,h)anthracene","range":""},{"name":"benzo(ghi)perylene","range":""},{"name":"indeno(1,2,3-cd)pyrene","range":""},{"name":"benzo(e)pyrene","range":""},{"name":"perylene","range":""}],"parameters_zh":[{"name":"萘","range":""},{"name":"苊烯","range":""},{"name":"苊","range":""},{"name":"芴","range":""},{"name":"荧蒽","range":""},{"name":"菲","range":""},{"name":"蒽","range":""},{"name":"芘","range":""},{"name":"苯并(a)蒽","range":""},{"name":"䓛","range":""},{"name":"苯并(b)荧蒽","range":""},{"name":"苯并(k)荧蒽","range":""},{"name":"苯并(a)芘","range":""},{"name":"二苯并(a,h)蒽","range":""},{"name":"苯并(ghi)苝","range":""},{"name":"茚并(1,2,3-cd)芘","range":""},{"name":"苯并(e)芘","range":""},{"name":"苝","range":""}],"parameters_cs":[{"name":"Naphtalene","range":""},{"name":"acenaphtylene","range":""},{"name":"acenaphtene","range":""},{"name":"fluorene","range":""},{"name":"fluoranthene","range":""},{"name":"phenanthrene","range":""},{"name":"anthracene","range":""},{"name":"pyrene","range":""},{"name":"benzo(a)anthracene","range":""},{"name":"chrysene","range":""},{"name":"benzo(b)fluoranthene","range":""},{"name":"benzo(k)fluoranthene","range":""},{"name":"benzo(a)pyrene","range":""},{"name":"dibenzo(a,h)anthracene","range":""},{"name":"benzo(ghi)perylene","range":""},{"name":"indeno(1,2,3-cd)pyrene","range":""},{"name":"benzo(e)pyrene","range":""},{"name":"perylene","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wielopierścieniowych węglowodorów aromatycznych metodą HPLC/UV, FLD\nZakres:\nNaftalen\nacenaftylen\nacenaften\nfluoren\nfluoranten\nfenantren\nantracen\npiren\nbenzo(a)antracen\nchryzen\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a)piren\ndibenzo(a,h)antracen\nbenzo(ghi)perylen\nindeno(1,2,3-cd)piren\nbenzo(e)piren\nperylen","reference":"JPP ÚKZÚZ, 30660.1","norm_bases":["JPP ÚKZÚZ, 30660.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie zawartości wielopierścieniowych węglowodorów aromatycznych metodą HPLC/UV, FLD Naftalen  acenaftylen  acenaften  fluoren  fluoranten  fenantren  antracen  piren  benzo(a)antracen  chryzen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)piren  dibenzo(a,h)antracen  benzo(ghi)perylen  indeno(1,2,3-cd)piren  benzo(e)piren  perylen  Půdy, kaly, sedimenty Stanovení obsahu polyaromatických uhlovodíků metodou HPLC/UV, FLD Naphtalene  acenaphtylene  acenaphtene  fluorene  fluoranthene  phenanthrene  anthracene  pyrene  benzo(a)anthracene  chrysene  benzo(b)fluoranthene  benzo(k)fluoranthene  benzo(a)pyrene  dibenzo(a,h)anthracene  benzo(ghi)perylene  indeno(1,2,3-cd)pyrene  benzo(e)pyrene  perylene  JPP ÚKZÚZ, 30660.1 Gleby, osady, osady denne Oznaczanie zawartosci wielopierscieniowych weglowodorow aromatycznych metoda HPLC/UV, FLD Naftalen  acenaftylen  acenaften  fluoren  fluoranten  fenantren  antracen  piren  benzo(a)antracen  chryzen  benzo(b)fluoranten  benzo(k)fluoranten  benzo(a)piren  dibenzo(a,h)antracen  benzo(ghi)perylen  indeno(1,2,3-cd)piren  benzo(e)piren  perylen  Pudy, kaly, sedimenty Stanoveni obsahu polyaromatickych uhlovodiku metodou HPLC/UV, FLD Naphtalene  acenaphtylene  acenaphtene  fluorene  fluoranthene  phenanthrene  anthracene  pyrene  benzo(a)anthracene  chrysene  benzo(b)fluoranthene  benzo(k)fluoranthene  benzo(a)pyrene  dibenzo(a,h)anthracene  benzo(ghi)perylene  indeno(1,2,3-cd)pyrene  benzo(e)pyrene  perylene  JPP UKZUZ, 30660.1","search_en":"Soil, sludge, sediments Determination of polyaromatic hydrocarbons by HPLC/UV, FLD method Naphthalene  acenaphthylene  acenaphthene  fluorene  fluoranthene  phenanthrene  anthracene  pyrene  benzo(a)anthracene  chrysene  benzo(b)fluoranthene  benzo(k)fluoranthene  benzo(a)pyrene  dibenzo(a,h)anthracene  benzo(ghi)perylene  indeno(1,2,3-cd)pyrene  benzo(e)pyrene  perylene  JPP ÚKZÚZ, 30660.1","search_zh":"土壤、污泥、沉积物 HPLC/UV、FLD法测定多环芳烃含量 萘  苊烯  苊  芴  荧蒽  菲  蒽  芘  苯并(a)蒽  䓛  苯并(b)荧蒽  苯并(k)荧蒽  苯并(a)芘  二苯并(a,h)蒽  苯并(ghi)苝  茚并(1,2,3-cd)芘  苯并(e)芘  苝  JPP ÚKZÚZ, 30660.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":124,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"134d24ccf144bd3758f22598","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"18","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą FAES","methodology_en":"Determination of selected elements by FAES method","methodology_zh":"FAES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou FAES","parameters":[{"name":"Sód (Na)","range":""},{"name":"Potas (K)","range":""}],"parameters_en":[{"name":"Sodium (Na)","range":""},{"name":"Potassium (K)","range":""}],"parameters_zh":[{"name":"钠（Na）","range":""},{"name":"钾（K）","range":""}],"parameters_cs":[{"name":"Na","range":""},{"name":"K","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą FAES\nZakres:\nSód (Na)\nPotas (K)","reference":"JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40080.1","norm_bases":["JPP ÚKZÚZ, 40018.1","JPP ÚKZÚZ, 40080.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości wybranych pierwiastków metodą FAES Sód (Na)  Potas (K)  Rostlinný materiál Stanovení obsahu vybraných prvků metodou FAES Na  K  JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40080.1 Material roslinny Oznaczanie zawartosci wybranych pierwiastkow metoda FAES Sod (Na)  Potas (K)  Rostlinny material Stanoveni obsahu vybranych prvku metodou FAES Na  K  JPP UKZUZ, 40018.1; JPP UKZUZ, 40080.1","search_en":"Plant material Determination of selected elements by FAES method Sodium (Na)  Potassium (K)  JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40080.1","search_zh":"植物材料 FAES法测定选定元素含量 钠（Na）  钾（K）  JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40080.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":125,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b9f8bb9771e8af5dd79438b1","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"19","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą FAAS","methodology_en":"Determination of selected elements by FAAS method","methodology_zh":"FAAS法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou FAAS","parameters":[{"name":"Ołów (Pb)","range":""},{"name":"Kadm (Cd)","range":""}],"parameters_en":[{"name":"Lead (Pb)","range":""},{"name":"Cadmium (Cd)","range":""}],"parameters_zh":[{"name":"铅（Pb）","range":""},{"name":"镉（Cd）","range":""}],"parameters_cs":[{"name":"Pb","range":""},{"name":"Cd","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą FAAS\nZakres:\nOłów (Pb)\nKadm (Cd)","reference":"JPP ÚKZÚZ, 10450.1","norm_bases":["JPP ÚKZÚZ, 10450.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wybranych pierwiastków metodą FAAS Ołów (Pb)  Kadm (Cd)  Krmiva a suroviny pro jejich výrobu Stanovení obsahu vybraných prvků metodou FAAS Pb  Cd  JPP ÚKZÚZ, 10450.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wybranych pierwiastkow metoda FAAS Olow (Pb)  Kadm (Cd)  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vybranych prvku metodou FAAS Pb  Cd  JPP UKZUZ, 10450.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of selected elements by FAAS method Lead (Pb)  Cadmium (Cd)  JPP ÚKZÚZ, 10450.1","search_zh":"饲料及其生产原料 FAAS法测定选定元素含量 铅（Pb）  镉（Cd）  JPP ÚKZÚZ, 10450.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":126,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2abe26246129cd7d349b3ef4","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"20","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą FAAS","methodology_en":"Determination of selected elements by FAAS method","methodology_zh":"FAAS法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou FAAS","parameters":[{"name":"Wapń (Ca)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Kadm (Cd)","range":""}],"parameters_en":[{"name":"Calcium (Ca)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Cadmium (Cd)","range":""}],"parameters_zh":[{"name":"钙（Ca）","range":""},{"name":"镁（Mg）","range":""},{"name":"铅（Pb）","range":""},{"name":"镉（Cd）","range":""}],"parameters_cs":[{"name":"Ca","range":""},{"name":"Mg","range":""},{"name":"Pb","range":""},{"name":"Cd","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą FAAS\nZakres:\nWapń (Ca)\nMagnez (Mg)\nOłów (Pb)\nKadm (Cd)","reference":"JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40034.1; JPP ÚKZÚZ, 40070.1; JPP ÚKZÚZ, 40110.1","norm_bases":["JPP ÚKZÚZ, 40018.1","JPP ÚKZÚZ, 40034.1","JPP ÚKZÚZ, 40070.1","JPP ÚKZÚZ, 40110.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości wybranych pierwiastków metodą FAAS Wapń (Ca)  Magnez (Mg)  Ołów (Pb)  Kadm (Cd)  Rostlinný materiál Stanovení obsahu vybraných prvků metodou FAAS Ca  Mg  Pb  Cd  JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40034.1; JPP ÚKZÚZ, 40070.1; JPP ÚKZÚZ, 40110.1 Material roslinny Oznaczanie zawartosci wybranych pierwiastkow metoda FAAS Wapn (Ca)  Magnez (Mg)  Olow (Pb)  Kadm (Cd)  Rostlinny material Stanoveni obsahu vybranych prvku metodou FAAS Ca  Mg  Pb  Cd  JPP UKZUZ, 40018.1; JPP UKZUZ, 40034.1; JPP UKZUZ, 40070.1; JPP UKZUZ, 40110.1","search_en":"Plant material Determination of selected elements by FAAS method Calcium (Ca)  Magnesium (Mg)  Lead (Pb)  Cadmium (Cd)  JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40034.1; JPP ÚKZÚZ, 40070.1; JPP ÚKZÚZ, 40110.1","search_zh":"植物材料 FAAS法测定选定元素含量 钙（Ca）  镁（Mg）  铅（Pb）  镉（Cd）  JPP ÚKZÚZ, 40018.1; JPP ÚKZÚZ, 40034.1; JPP ÚKZÚZ, 40070.1; JPP ÚKZÚZ, 40110.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":127,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c0ff8216e804a31a204cf96e","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"21","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie uziarnienia metodą pipetową i wagową","methodology_en":"Determination of particle size distribution by pipette method and gravimetric method","methodology_zh":"移液管法和重量法测定粒度组成","methodology_cs":"Stanovení zrnitosti pipetovací metodou a gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia metodą pipetową i wagową","reference":"JPP ÚKZÚZ, 30250.1","norm_bases":["JPP ÚKZÚZ, 30250.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane frakcje: cząstki poniżej 0,001 mm, poniżej 0,002 mm, poniżej 0,006 mm, poniżej 0,01 mm, poniżej 0,05 mm, poniżej 0,063 mm, cząstki od 0,001 do 0,01 mm, od 0,01 do 0,05 mm, od 0,051 do 0,25 mm, od 0,25 do 2,0 mm, od 2,0 do 4,0 mm","note_en":"Determined fractions: particles below 0.001 mm, below 0.002 mm, below 0.006 mm, below 0.01 mm, below 0.05 mm, below 0.063 mm, particles from 0.001 to 0.01 mm, from 0.01 to 0.05 mm, from 0.051 to 0.25 mm, from 0.25 to 2.0 mm, from 2.0 to 4.0 mm","note_zh":"测定粒级：小于0.001 mm、小于0.002 mm、小于0.006 mm、小于0.01 mm、小于0.05 mm、小于0.063 mm的颗粒，0.001–0.01 mm、0.01–0.05 mm、0.051–0.25 mm、0.25–2.0 mm、2.0–4.0 mm的颗粒","note_cs":"Stanovované frakce: částice pod 0,001 mm, částice pod 0,002 mm, částice pod 0,006 mm, částice pod 0,01 mm, částice pod 0,05 mm, částice pod 0,063 mm, částice od 0,001 do 0,01mm, částice od 0,01 do 0,05mm, částice od 0,051 do 0,25mm, částice od 0,25 do 2,0 mm, částice od 2,0 do 4,0 mm","search_text":"Gleby, osady, osady denne Oznaczanie uziarnienia metodą pipetową i wagową Půdy, kaly, sedimenty Stanovení zrnitosti pipetovací metodou a gravimetricky JPP ÚKZÚZ, 30250.1 Gleby, osady, osady denne Oznaczanie uziarnienia metoda pipetowa i wagowa Pudy, kaly, sedimenty Stanoveni zrnitosti pipetovaci metodou a gravimetricky JPP UKZUZ, 30250.1","search_en":"Soil, sludge, sediments Determination of particle size distribution by pipette method and gravimetric method JPP ÚKZÚZ, 30250.1","search_zh":"土壤、污泥、沉积物 移液管法和重量法测定粒度组成 JPP ÚKZÚZ, 30250.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":128,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7e202af6f7e772a49140f9f4","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"22","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie pH metodą ISE","methodology_en":"Determination of pH by ISE method","methodology_zh":"离子选择电极法测定pH","methodology_cs":"Stanovení pH metodou ISE","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą ISE","reference":"JPP ÚKZÚZ, 30040.1; JPP ÚKZÚZ, 30042.1","norm_bases":["JPP ÚKZÚZ, 30040.1","JPP ÚKZÚZ, 30042.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie pH metodą ISE Půdy, kaly, sedimenty Stanovení pH metodou ISE JPP ÚKZÚZ, 30040.1; JPP ÚKZÚZ, 30042.1 Gleby, osady, osady denne Oznaczanie pH metoda ISE Pudy, kaly, sedimenty Stanoveni pH metodou ISE JPP UKZUZ, 30040.1; JPP UKZUZ, 30042.1","search_en":"Soil, sludge, sediments Determination of pH by ISE method JPP ÚKZÚZ, 30040.1; JPP ÚKZÚZ, 30042.1","search_zh":"土壤、污泥、沉积物 离子选择电极法测定pH JPP ÚKZÚZ, 30040.1; JPP ÚKZÚZ, 30042.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":129,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5be73e1d23a3fa1f19218a10","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"23","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES","methodology_en":"Determination of selected elements by ICP-OES method","methodology_zh":"ICP-OES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou ICP-OES","parameters":[{"name":"Cynk (Zn)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Sód (Na)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Arsen (As)","range":""},{"name":"Selen (Se)","range":""}],"parameters_en":[{"name":"Zinc (Zn)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Selenium (Se)","range":""}],"parameters_zh":[{"name":"锌（Zn）","range":""},{"name":"钴（Co）","range":""},{"name":"镍（Ni）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"锰（Mn）","range":""},{"name":"铁（Fe）","range":""},{"name":"钙（Ca）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"钠（Na）","range":""},{"name":"磷（P）","range":""},{"name":"砷（As）","range":""},{"name":"硒（Se）","range":""}],"parameters_cs":[{"name":"Zn","range":""},{"name":"Co","range":""},{"name":"Ni","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Mn","range":""},{"name":"Fe","range":""},{"name":"Ca","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Na","range":""},{"name":"P","range":""},{"name":"As","range":""},{"name":"Se","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES\nZakres:\nCynk (Zn)\nKobalt (Co)\nNikiel (Ni)\nChrom (Cr)\nMiedź (Cu)\nMangan (Mn)\nŻelazo (Fe)\nWapń (Ca)\nPotas (K)\nMagnez (Mg)\nSód (Na)\nFosfor (P)\nArsen (As)\nSelen (Se)","reference":"JPP ÚKZÚZ, 10150.1; JPP ÚKZÚZ, 10320.1; JPP ÚKZÚZ, 10480.1; JPP ÚKZÚZ, 10282.1","norm_bases":["JPP ÚKZÚZ, 10150.1","JPP ÚKZÚZ, 10320.1","JPP ÚKZÚZ, 10480.1","JPP ÚKZÚZ, 10282.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES Cynk (Zn)  Kobalt (Co)  Nikiel (Ni)  Chrom (Cr)  Miedź (Cu)  Mangan (Mn)  Żelazo (Fe)  Wapń (Ca)  Potas (K)  Magnez (Mg)  Sód (Na)  Fosfor (P)  Arsen (As)  Selen (Se)  Krmiva a suroviny pro jejich výrobu Stanovení obsahu vybraných prvků metodou ICP-OES Zn  Co  Ni  Cr  Cu  Mn  Fe  Ca  K  Mg  Na  P  As  Se  JPP ÚKZÚZ, 10150.1; JPP ÚKZÚZ, 10320.1; JPP ÚKZÚZ, 10480.1; JPP ÚKZÚZ, 10282.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wybranych pierwiastkow metoda ICP-OES Cynk (Zn)  Kobalt (Co)  Nikiel (Ni)  Chrom (Cr)  Miedz (Cu)  Mangan (Mn)  Zelazo (Fe)  Wapn (Ca)  Potas (K)  Magnez (Mg)  Sod (Na)  Fosfor (P)  Arsen (As)  Selen (Se)  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vybranych prvku metodou ICP-OES Zn  Co  Ni  Cr  Cu  Mn  Fe  Ca  K  Mg  Na  P  As  Se  JPP UKZUZ, 10150.1; JPP UKZUZ, 10320.1; JPP UKZUZ, 10480.1; JPP UKZUZ, 10282.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of selected elements by ICP-OES method Zinc (Zn)  Cobalt (Co)  Nickel (Ni)  Chromium (Cr)  Copper (Cu)  Manganese (Mn)  Iron (Fe)  Calcium (Ca)  Potassium (K)  Magnesium (Mg)  Sodium (Na)  Phosphorus (P)  Arsenic (As)  Selenium (Se)  JPP ÚKZÚZ, 10150.1; JPP ÚKZÚZ, 10320.1; JPP ÚKZÚZ, 10480.1; JPP ÚKZÚZ, 10282.1","search_zh":"饲料及其生产原料 ICP-OES法测定选定元素含量 锌（Zn）  钴（Co）  镍（Ni）  铬（Cr）  铜（Cu）  锰（Mn）  铁（Fe）  钙（Ca）  钾（K）  镁（Mg）  钠（Na）  磷（P）  砷（As）  硒（Se）  JPP ÚKZÚZ, 10150.1; JPP ÚKZÚZ, 10320.1; JPP ÚKZÚZ, 10480.1; JPP ÚKZÚZ, 10282.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":130,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"14b6604246854234de047359","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"24","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości pierwiastków metodą ICP-OES","methodology_en":"Determination of elements by ICP-OES method","methodology_zh":"ICP-OES法测定元素含量","methodology_cs":"Stanovení obsahu prvků metodou ICP-OES","parameters":[{"name":"Glin (Al)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Siarka (S)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Bor (B)","range":""}],"parameters_en":[{"name":"Aluminium (Al)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Sulphur (S)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Boron (B)","range":""}],"parameters_zh":[{"name":"铝（Al）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"磷（P）","range":""},{"name":"硫（S）","range":""},{"name":"铜（Cu）","range":""},{"name":"锰（Mn）","range":""},{"name":"锌（Zn）","range":""},{"name":"铁（Fe）","range":""},{"name":"硼（B）","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"P","range":""},{"name":"S","range":""},{"name":"Cu","range":""},{"name":"Mn","range":""},{"name":"Zn","range":""},{"name":"Fe","range":""},{"name":"B","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości pierwiastków metodą ICP-OES\nZakres:\nGlin (Al)\nWapń (Ca)\nKadm (Cd)\nPotas (K)\nMagnez (Mg)\nFosfor (P)\nSiarka (S)\nMiedź (Cu)\nMangan (Mn)\nCynk (Zn)\nŻelazo (Fe)\nBor (B)","reference":"JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30074.1","norm_bases":["JPP ÚKZÚZ, 30068.1","JPP ÚKZÚZ, 30074.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie zawartości pierwiastków metodą ICP-OES Glin (Al)  Wapń (Ca)  Kadm (Cd)  Potas (K)  Magnez (Mg)  Fosfor (P)  Siarka (S)  Miedź (Cu)  Mangan (Mn)  Cynk (Zn)  Żelazo (Fe)  Bor (B)  Půdy, kaly, sedimenty Stanovení obsahu prvků metodou ICP-OES Al  Ca  Cd  K  Mg  P  S  Cu  Mn  Zn  Fe  B  JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30074.1 Gleby, osady, osady denne Oznaczanie zawartosci pierwiastkow metoda ICP-OES Glin (Al)  Wapn (Ca)  Kadm (Cd)  Potas (K)  Magnez (Mg)  Fosfor (P)  Siarka (S)  Miedz (Cu)  Mangan (Mn)  Cynk (Zn)  Zelazo (Fe)  Bor (B)  Pudy, kaly, sedimenty Stanoveni obsahu prvku metodou ICP-OES Al  Ca  Cd  K  Mg  P  S  Cu  Mn  Zn  Fe  B  JPP UKZUZ, 30068.1; JPP UKZUZ, 30074.1","search_en":"Soil, sludge, sediments Determination of elements by ICP-OES method Aluminium (Al)  Calcium (Ca)  Cadmium (Cd)  Potassium (K)  Magnesium (Mg)  Phosphorus (P)  Sulphur (S)  Copper (Cu)  Manganese (Mn)  Zinc (Zn)  Iron (Fe)  Boron (B)  JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30074.1","search_zh":"土壤、污泥、沉积物 ICP-OES法测定元素含量 铝（Al）  钙（Ca）  镉（Cd）  钾（K）  镁（Mg）  磷（P）  硫（S）  铜（Cu）  锰（Mn）  锌（Zn）  铁（Fe）  硼（B）  JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30074.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":131,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3a46763ca2ab895c6fb0e9e1","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"25","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES","methodology_en":"Determination of selected elements by ICP-OES method","methodology_zh":"ICP-OES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou ICP-OES","parameters":[{"name":"Cynk (Zn)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Wanad (V)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Glin (Al)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Sód (Na)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Siarka (S)","range":""},{"name":"Arsen (As)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Kadm (Cd)","range":""}],"parameters_en":[{"name":"Zinc (Zn)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Sulphur (S)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Cadmium (Cd)","range":""}],"parameters_zh":[{"name":"锌（Zn）","range":""},{"name":"钴（Co）","range":""},{"name":"镍（Ni）","range":""},{"name":"铬（Cr）","range":""},{"name":"钒（V）","range":""},{"name":"铍（Be）","range":""},{"name":"铜（Cu）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"铁（Fe）","range":""},{"name":"铝（Al）","range":""},{"name":"钙（Ca）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"钠（Na）","range":""},{"name":"磷（P）","range":""},{"name":"硫（S）","range":""},{"name":"砷（As）","range":""},{"name":"铅（Pb）","range":""},{"name":"镉（Cd）","range":""}],"parameters_cs":[{"name":"Zn","range":""},{"name":"Co","range":""},{"name":"Ni","range":""},{"name":"Cr","range":""},{"name":"V","range":""},{"name":"Be","range":""},{"name":"Cu","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Fe","range":""},{"name":"Al","range":""},{"name":"Ca","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Na","range":""},{"name":"P","range":""},{"name":"S","range":""},{"name":"As","range":""},{"name":"Pb","range":""},{"name":"Cd","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES\nZakres:\nCynk (Zn)\nKobalt (Co)\nNikiel (Ni)\nChrom (Cr)\nWanad (V)\nBeryl (Be)\nMiedź (Cu)\nMangan (Mn)\nMolibden (Mo)\nŻelazo (Fe)\nGlin (Al)\nWapń (Ca)\nPotas (K)\nMagnez (Mg)\nSód (Na)\nFosfor (P)\nSiarka (S)\nArsen (As)\nOłów (Pb)\nKadm (Cd)","reference":"JPP ÚKZÚZ, 30350.2; JPP ÚKZÚZ, 30500.2","norm_bases":["JPP ÚKZÚZ, 30350.2","JPP ÚKZÚZ, 30500.2"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES Cynk (Zn)  Kobalt (Co)  Nikiel (Ni)  Chrom (Cr)  Wanad (V)  Beryl (Be)  Miedź (Cu)  Mangan (Mn)  Molibden (Mo)  Żelazo (Fe)  Glin (Al)  Wapń (Ca)  Potas (K)  Magnez (Mg)  Sód (Na)  Fosfor (P)  Siarka (S)  Arsen (As)  Ołów (Pb)  Kadm (Cd)  Půdy, kaly, sedimenty Stanovení obsahu vybraných prvků metodou ICP-OES Zn  Co  Ni  Cr  V  Be  Cu  Mn  Mo  Fe  Al  Ca  K  Mg  Na  P  S  As  Pb  Cd  JPP ÚKZÚZ, 30350.2; JPP ÚKZÚZ, 30500.2 Gleby, osady, osady denne Oznaczanie zawartosci wybranych pierwiastkow metoda ICP-OES Cynk (Zn)  Kobalt (Co)  Nikiel (Ni)  Chrom (Cr)  Wanad (V)  Beryl (Be)  Miedz (Cu)  Mangan (Mn)  Molibden (Mo)  Zelazo (Fe)  Glin (Al)  Wapn (Ca)  Potas (K)  Magnez (Mg)  Sod (Na)  Fosfor (P)  Siarka (S)  Arsen (As)  Olow (Pb)  Kadm (Cd)  Pudy, kaly, sedimenty Stanoveni obsahu vybranych prvku metodou ICP-OES Zn  Co  Ni  Cr  V  Be  Cu  Mn  Mo  Fe  Al  Ca  K  Mg  Na  P  S  As  Pb  Cd  JPP UKZUZ, 30350.2; JPP UKZUZ, 30500.2","search_en":"Soil, sludge, sediments Determination of selected elements by ICP-OES method Zinc (Zn)  Cobalt (Co)  Nickel (Ni)  Chromium (Cr)  Vanadium (V)  Beryllium (Be)  Copper (Cu)  Manganese (Mn)  Molybdenum (Mo)  Iron (Fe)  Aluminium (Al)  Calcium (Ca)  Potassium (K)  Magnesium (Mg)  Sodium (Na)  Phosphorus (P)  Sulphur (S)  Arsenic (As)  Lead (Pb)  Cadmium (Cd)  JPP ÚKZÚZ, 30350.2; JPP ÚKZÚZ, 30500.2","search_zh":"土壤、污泥、沉积物 ICP-OES法测定选定元素含量 锌（Zn）  钴（Co）  镍（Ni）  铬（Cr）  钒（V）  铍（Be）  铜（Cu）  锰（Mn）  钼（Mo）  铁（Fe）  铝（Al）  钙（Ca）  钾（K）  镁（Mg）  钠（Na）  磷（P）  硫（S）  砷（As）  铅（Pb）  镉（Cd）  JPP ÚKZÚZ, 30350.2; JPP ÚKZÚZ, 30500.2","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":132,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cd5c3c27c6c77e5bd94d0050","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"26","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES","methodology_en":"Determination of selected elements by ICP-OES method","methodology_zh":"ICP-OES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou ICP-OES","parameters":[{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Sód (Na)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Siarka (S)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Sulphur (S)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"钠（Na）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"硫（S）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"S","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES\nZakres:\nGlin (Al)\nArsen (As)\nBor (B)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nSód (Na)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nSiarka (S)\nWanad (V)\nCynk (Zn)","reference":"JPP ÚKZÚZ, 40030.1; JPP ÚKZÚZ, 40034.1; JPP ÚKZÚZ, 40090.1; JPP ÚKZÚZ, 40100.1","norm_bases":["JPP ÚKZÚZ, 40030.1","JPP ÚKZÚZ, 40034.1","JPP ÚKZÚZ, 40090.1","JPP ÚKZÚZ, 40100.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES Glin (Al)  Arsen (As)  Bor (B)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sód (Na)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Siarka (S)  Wanad (V)  Cynk (Zn)  Rostlinný materiál Stanovení obsahu vybraných prvků metodou ICP-OES Al  As  B  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Na  Ni  P  Pb  S  V  Zn  JPP ÚKZÚZ, 40030.1; JPP ÚKZÚZ, 40034.1; JPP ÚKZÚZ, 40090.1; JPP ÚKZÚZ, 40100.1 Material roslinny Oznaczanie zawartosci wybranych pierwiastkow metoda ICP-OES Glin (Al)  Arsen (As)  Bor (B)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sod (Na)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Siarka (S)  Wanad (V)  Cynk (Zn)  Rostlinny material Stanoveni obsahu vybranych prvku metodou ICP-OES Al  As  B  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Na  Ni  P  Pb  S  V  Zn  JPP UKZUZ, 40030.1; JPP UKZUZ, 40034.1; JPP UKZUZ, 40090.1; JPP UKZUZ, 40100.1","search_en":"Plant material Determination of selected elements by ICP-OES method Aluminium (Al)  Arsenic (As)  Boron (B)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Sodium (Na)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Sulphur (S)  Vanadium (V)  Zinc (Zn)  JPP ÚKZÚZ, 40030.1; JPP ÚKZÚZ, 40034.1; JPP ÚKZÚZ, 40090.1; JPP ÚKZÚZ, 40100.1","search_zh":"植物材料 ICP-OES法测定选定元素含量 铝（Al）  砷（As）  硼（B）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  钼（Mo）  钠（Na）  镍（Ni）  磷（P）  铅（Pb）  硫（S）  钒（V）  锌（Zn）  JPP ÚKZÚZ, 40030.1; JPP ÚKZÚZ, 40034.1; JPP ÚKZÚZ, 40090.1; JPP ÚKZÚZ, 40100.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":133,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c72e0f8ecc6615fada4953a4","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"27","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości Hg na aparacie AMA","methodology_en":"Determination of mercury using AMA instrument","methodology_zh":"AMA仪器测定汞含量","methodology_cs":"Stanovení obsahu Hg na přístroji AMA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości Hg na aparacie AMA","reference":"JPP ÚKZÚZ, 10420.1","norm_bases":["JPP ÚKZÚZ, 10420.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości Hg na aparacie AMA Krmiva a suroviny pro jejich výrobu Stanovení obsahu Hg na přístroji AMA JPP ÚKZÚZ, 10420.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci Hg na aparacie AMA Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu Hg na pristroji AMA JPP UKZUZ, 10420.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of mercury using AMA instrument JPP ÚKZÚZ, 10420.1","search_zh":"饲料及其生产原料 AMA仪器测定汞含量 JPP ÚKZÚZ, 10420.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":134,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"301c601840df07c37d41aad5","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"28","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości Hg na aparacie AMA","methodology_en":"Determination of mercury using AMA instrument","methodology_zh":"AMA仪器测定汞含量","methodology_cs":"Stanovení obsahu Hg na přístroji AMA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości Hg na aparacie AMA","reference":"JPP ÚKZÚZ, 30460.1","norm_bases":["JPP ÚKZÚZ, 30460.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie zawartości Hg na aparacie AMA Půdy, kaly, sedimenty Stanovení obsahu Hg na přístroji AMA JPP ÚKZÚZ, 30460.1 Gleby, osady, osady denne Oznaczanie zawartosci Hg na aparacie AMA Pudy, kaly, sedimenty Stanoveni obsahu Hg na pristroji AMA JPP UKZUZ, 30460.1","search_en":"Soil, sludge, sediments Determination of mercury using AMA instrument JPP ÚKZÚZ, 30460.1","search_zh":"土壤、污泥、沉积物 AMA仪器测定汞含量 JPP ÚKZÚZ, 30460.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":135,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1ad395e8b22654ae20e872e4","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"29","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości Hg na aparacie AMA","methodology_en":"Determination of mercury using AMA instrument","methodology_zh":"AMA仪器测定汞含量","methodology_cs":"Stanovení obsahu Hg na přístroji AMA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości Hg na aparacie AMA","reference":"JPP ÚKZÚZ, 40190.1","norm_bases":["JPP ÚKZÚZ, 40190.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości Hg na aparacie AMA Rostlinný materiál Stanovení obsahu Hg na přístroji AMA JPP ÚKZÚZ, 40190.1 Material roslinny Oznaczanie zawartosci Hg na aparacie AMA Rostlinny material Stanoveni obsahu Hg na pristroji AMA JPP UKZUZ, 40190.1","search_en":"Plant material Determination of mercury using AMA instrument JPP ÚKZÚZ, 40190.1","search_zh":"植物材料 AMA仪器测定汞含量 JPP ÚKZÚZ, 40190.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":136,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1ddf71414ab9ffb607e5eee9","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"30","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie wybranych parametrów metodą NIRS","methodology_en":"Determination of selected parameters by NIRS method","methodology_zh":"NIRS法测定选定参数","methodology_cs":"Stanovení vybraných parametrů metodou NIRS","parameters":[{"name":"Tłuszcz","range":""},{"name":"olej","range":""}],"parameters_en":[{"name":"Fat","range":""},{"name":"oil","range":""}],"parameters_zh":[{"name":"脂肪","range":""},{"name":"油","range":""}],"parameters_cs":[{"name":"Tuk","range":""},{"name":"olej","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych parametrów metodą NIRS\nZakres:\nTłuszcz\nolej","reference":"JPP ÚKZÚZ, 50050.1","norm_bases":["JPP ÚKZÚZ, 50050.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie wybranych parametrów metodą NIRS Tłuszcz  olej  Rostlinný materiál Stanovení vybraných parametrů metodou NIRS Tuk  olej  JPP ÚKZÚZ, 50050.1 Material roslinny Oznaczanie wybranych parametrow metoda NIRS Tluszcz  olej  Rostlinny material Stanoveni vybranych parametru metodou NIRS Tuk  olej  JPP UKZUZ, 50050.1","search_en":"Plant material Determination of selected parameters by NIRS method Fat  oil  JPP ÚKZÚZ, 50050.1","search_zh":"植物材料 NIRS法测定选定参数 脂肪  油  JPP ÚKZÚZ, 50050.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":137,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c0f4ccd36e3471931b9b125a","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"31","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie substancji azotowych metodą NIRS","methodology_en":"Determination of nitrogenous substances by NIRS method","methodology_zh":"NIRS法测定含氮物质","methodology_cs":"Stanovení dusíkatých látek metodou NIRS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji azotowych metodą NIRS","reference":"JPP ÚKZÚZ, 50050.1","norm_bases":["JPP ÚKZÚZ, 50050.1"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie substancji azotowych metodą NIRS Rostlinný materiál Stanovení dusíkatých látek metodou NIRS JPP ÚKZÚZ, 50050.1 Material roslinny Oznaczanie substancji azotowych metoda NIRS Rostlinny material Stanoveni dusikatych latek metodou NIRS JPP UKZUZ, 50050.1","search_en":"Plant material Determination of nitrogenous substances by NIRS method JPP ÚKZÚZ, 50050.1","search_zh":"植物材料 NIRS法测定含氮物质 JPP ÚKZÚZ, 50050.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":138,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6d9a4a4383ce56ad09b47c89","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"32","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie teobrominy i kofeiny metodą HPLC z detekcją UV","methodology_en":"Determination of theobromine and caffeine by HPLC method with UV detection","methodology_zh":"HPLC紫外检测法测定可可碱和咖啡因","methodology_cs":"Stanovení theobrominu a kofeinu metodou HPLC s UV detekcí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie teobrominy i kofeiny metodą HPLC z detekcją UV","reference":"JPP ÚKZÚZ, 10542.2","norm_bases":["JPP ÚKZÚZ, 10542.2"],"lab_section":"ÚKZÚZ, NRL, Wydział NRL Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of NRL Opava","lab_section_zh":"ÚKZÚZ, NRL，NRL奥帕瓦处","lab_section_cs":"ÚKZÚZ, NRL, Odbor NRL Opava","lab_address":"Jaselská 16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie teobrominy i kofeiny metodą HPLC z detekcją UV Krmiva a suroviny pro jejich výrobu Stanovení theobrominu a kofeinu metodou HPLC s UV detekcí JPP ÚKZÚZ, 10542.2 Pasze i surowce do ich produkcji Oznaczanie teobrominy i kofeiny metoda HPLC z detekcja UV Krmiva a suroviny pro jejich vyrobu Stanoveni theobrominu a kofeinu metodou HPLC s UV detekci JPP UKZUZ, 10542.2","search_en":"Animal feeding stuffs and raw materials for their production Determination of theobromine and caffeine by HPLC method with UV detection JPP ÚKZÚZ, 10542.2","search_zh":"饲料及其生产原料 HPLC紫外检测法测定可可碱和咖啡因 JPP ÚKZÚZ, 10542.2","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":139,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b2cc23883f10738970a7ce5f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"1","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP ÚKZÚZ, 30020.1","norm_bases":["JPP ÚKZÚZ, 30020.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Půdy, kaly, sedimenty Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP ÚKZÚZ, 30020.1 Gleby, osady, osady denne Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Pudy, kaly, sedimenty Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 30020.1","search_en":"Soil, sludge, sediments Determination of moisture by gravimetric method and calculation of dry matter JPP ÚKZÚZ, 30020.1","search_zh":"土壤、污泥、沉积物 重量法测定水分含量并计算干物质 JPP ÚKZÚZ, 30020.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":140,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d232fb350711c0c03f24173f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"2","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP ÚKZÚZ, 20001.1","norm_bases":["JPP ÚKZÚZ, 20001.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nawozy i surowce do ich produkcji Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Hnojiva a suroviny pro jejich výrobu Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP ÚKZÚZ, 20001.1 Nawozy i surowce do ich produkcji Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Hnojiva a suroviny pro jejich vyrobu Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 20001.1","search_en":"Fertilizers and raw materials for their production Determination of moisture by gravimetric method and calculation of dry matter JPP ÚKZÚZ, 20001.1","search_zh":"肥料及其生产原料 重量法测定水分含量并计算干物质 JPP ÚKZÚZ, 20001.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":141,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3db7a16ce58bdf78bf2fa647","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"3","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP ÚKZÚZ, 40010.1","norm_bases":["JPP ÚKZÚZ, 40010.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Rostlinný materiál Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP ÚKZÚZ, 40010.1 Material roslinny Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Rostlinny material Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 40010.1","search_en":"Plant material Determination of moisture by gravimetric method and calculation of dry matter JPP ÚKZÚZ, 40010.1","search_zh":"植物材料 重量法测定水分含量并计算干物质 JPP ÚKZÚZ, 40010.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":142,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3be5eb586a2b29c9013b2b74","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"4","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie azotu całkowitego metodą analizy elementarnej","methodology_en":"Determination of total nitrogen by elemental analysis","methodology_zh":"元素分析法测定总氮","methodology_cs":"Stanovení celkového dusíku elementární analýzou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu całkowitego metodą analizy elementarnej","reference":"JPP ÚKZÚZ, 20320.1","norm_bases":["JPP ÚKZÚZ, 20320.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Uszczegółowienie: wyraża się jako N lub jako N w suchej masie","note_en":"Specification: Expressed as N or as N in dry matter","note_zh":"细化说明：以N或干物质中N表示","note_cs":"Upřesnění: Vyjadřuje se jako N nebo jako N v sušině","search_text":"Nawozy i surowce do ich produkcji Oznaczanie azotu całkowitego metodą analizy elementarnej Hnojiva a suroviny pro jejich výrobu Stanovení celkového dusíku elementární analýzou JPP ÚKZÚZ, 20320.1 Nawozy i surowce do ich produkcji Oznaczanie azotu calkowitego metoda analizy elementarnej Hnojiva a suroviny pro jejich vyrobu Stanoveni celkoveho dusiku elementarni analyzou JPP UKZUZ, 20320.1","search_en":"Fertilizers and raw materials for their production Determination of total nitrogen by elemental analysis JPP ÚKZÚZ, 20320.1","search_zh":"肥料及其生产原料 元素分析法测定总氮 JPP ÚKZÚZ, 20320.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":143,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"392a65da350834aa88bb5b52","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"5","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości chlorków rozpuszczalnych w wodzie metodą potencjometryczną","methodology_en":"Determination of water-soluble chlorides by potentiometric method","methodology_zh":"电位法测定水溶性氯化物含量","methodology_cs":"Stanovení obsahu chloridů rozpustných ve vodě potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości chlorków rozpuszczalnych w wodzie metodą potencjometryczną","reference":"JPP ÚKZÚZ, 20020.1","norm_bases":["JPP ÚKZÚZ, 20020.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nawozy i surowce do ich produkcji Oznaczanie zawartości chlorków rozpuszczalnych w wodzie metodą potencjometryczną Hnojiva a suroviny pro jejich výrobu Stanovení obsahu chloridů rozpustných ve vodě potenciometricky JPP ÚKZÚZ, 20020.1 Nawozy i surowce do ich produkcji Oznaczanie zawartosci chlorkow rozpuszczalnych w wodzie metoda potencjometryczna Hnojiva a suroviny pro jejich vyrobu Stanoveni obsahu chloridu rozpustnych ve vode potenciometricky JPP UKZUZ, 20020.1","search_en":"Fertilizers and raw materials for their production Determination of water-soluble chlorides by potentiometric method JPP ÚKZÚZ, 20020.1","search_zh":"肥料及其生产原料 电位法测定水溶性氯化物含量 JPP ÚKZÚZ, 20020.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":144,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ff8adef0284990c132802773","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"6","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości azotu amonowego metodą spektrofotometryczną","methodology_en":"Determination of ammonium nitrogen by spectrophotometric method","methodology_zh":"分光光度法测定铵态氮含量","methodology_cs":"Stanovení obsahu amonného dusíku spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu amonowego metodą spektrofotometryczną","reference":"JPP ÚKZÚZ, 20143.1","norm_bases":["JPP ÚKZÚZ, 20143.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Uszczegółowienie: wyraża się jako N","note_en":"Specification: Expressed as N","note_zh":"细化说明：以N表示","note_cs":"Upřesnění: Vyjadřuje se jako N","search_text":"Nawozy i surowce do ich produkcji Oznaczanie zawartości azotu amonowego metodą spektrofotometryczną Hnojiva a suroviny pro jejich výrobu Stanovení obsahu amonného dusíku spektrofotometricky JPP ÚKZÚZ, 20143.1 Nawozy i surowce do ich produkcji Oznaczanie zawartosci azotu amonowego metoda spektrofotometryczna Hnojiva a suroviny pro jejich vyrobu Stanoveni obsahu amonneho dusiku spektrofotometricky JPP UKZUZ, 20143.1","search_en":"Fertilizers and raw materials for their production Determination of ammonium nitrogen by spectrophotometric method JPP ÚKZÚZ, 20143.1","search_zh":"肥料及其生产原料 分光光度法测定铵态氮含量 JPP ÚKZÚZ, 20143.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":145,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"79980082e4c68109798a8b4f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"7","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości azotu azotanowego metodą spektrofotometryczną","methodology_en":"Determination of nitrate nitrogen by spectrophotometric method","methodology_zh":"分光光度法测定硝态氮含量","methodology_cs":"Stanovení obsahu dusičnanového dusíku spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu azotanowego metodą spektrofotometryczną","reference":"JPP ÚKZÚZ, 20144.1","norm_bases":["JPP ÚKZÚZ, 20144.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Uszczegółowienie: wyraża się jako N","note_en":"Specification: Expressed as N","note_zh":"细化说明：以N表示","note_cs":"Upřesnění: Vyjadřuje se jako N","search_text":"Nawozy i surowce do ich produkcji Oznaczanie zawartości azotu azotanowego metodą spektrofotometryczną Hnojiva a suroviny pro jejich výrobu Stanovení obsahu dusičnanového dusíku spektrofotometricky JPP ÚKZÚZ, 20144.1 Nawozy i surowce do ich produkcji Oznaczanie zawartosci azotu azotanowego metoda spektrofotometryczna Hnojiva a suroviny pro jejich vyrobu Stanoveni obsahu dusicnanoveho dusiku spektrofotometricky JPP UKZUZ, 20144.1","search_en":"Fertilizers and raw materials for their production Determination of nitrate nitrogen by spectrophotometric method JPP ÚKZÚZ, 20144.1","search_zh":"肥料及其生产原料 分光光度法测定硝态氮含量 JPP ÚKZÚZ, 20144.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":146,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25a01a4573d7010bff3551f5","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"8","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie pH metodą elektrochemiczną","methodology_en":"Determination of pH by electrochemical method","methodology_zh":"电化学法测定pH","methodology_cs":"Stanovení pH elektrochemicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą elektrochemiczną","reference":"JPP ÚKZÚZ, 20221.1; JPP ÚKZÚZ, 20376.1","norm_bases":["JPP ÚKZÚZ, 20221.1","JPP ÚKZÚZ, 20376.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nawozy i surowce do ich produkcji Oznaczanie pH metodą elektrochemiczną Hnojiva a suroviny pro jejich výrobu Stanovení pH elektrochemicky JPP ÚKZÚZ, 20221.1; JPP ÚKZÚZ, 20376.1 Nawozy i surowce do ich produkcji Oznaczanie pH metoda elektrochemiczna Hnojiva a suroviny pro jejich vyrobu Stanoveni pH elektrochemicky JPP UKZUZ, 20221.1; JPP UKZUZ, 20376.1","search_en":"Fertilizers and raw materials for their production Determination of pH by electrochemical method JPP ÚKZÚZ, 20221.1; JPP ÚKZÚZ, 20376.1","search_zh":"肥料及其生产原料 电化学法测定pH JPP ÚKZÚZ, 20221.1; JPP ÚKZÚZ, 20376.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":147,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cc75c89c06bba7379343cef6","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"9","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie pH metodą elektrochemiczną","methodology_en":"Determination of pH by electrochemical method","methodology_zh":"电化学法测定pH","methodology_cs":"Stanovení pH elektrochemicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą elektrochemiczną","reference":"JPP ÚKZÚZ, 30040.1","norm_bases":["JPP ÚKZÚZ, 30040.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie pH metodą elektrochemiczną Půdy, kaly, sedimenty Stanovení pH elektrochemicky JPP ÚKZÚZ, 30040.1 Gleby, osady, osady denne Oznaczanie pH metoda elektrochemiczna Pudy, kaly, sedimenty Stanoveni pH elektrochemicky JPP UKZUZ, 30040.1","search_en":"Soil, sludge, sediments Determination of pH by electrochemical method JPP ÚKZÚZ, 30040.1","search_zh":"土壤、污泥、沉积物 电化学法测定pH JPP ÚKZÚZ, 30040.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":148,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6801f4c272bb71a7532fcbe5","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"10","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES","methodology_en":"Determination of selected elements by ICP-OES method","methodology_zh":"ICP-OES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou ICP-OES","parameters":[{"name":"Arsen (As)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"砷（As）","range":""},{"name":"铍（Be）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"钼（Mo）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Be","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Mo","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES\nZakres:\nArsen (As)\nBeryl (Be)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nMolibden (Mo)\nNikiel (Ni)\nOłów (Pb)\nWanad (V)\nCynk (Zn)","reference":"JPP ÚKZÚZ, 30350.2; JPP ÚKZÚZ, 30500.2","norm_bases":["JPP ÚKZÚZ, 30350.2","JPP ÚKZÚZ, 30500.2"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES Arsen (As)  Beryl (Be)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Molibden (Mo)  Nikiel (Ni)  Ołów (Pb)  Wanad (V)  Cynk (Zn)  Půdy, kaly, sedimenty Stanovení obsahu vybraných prvků metodou ICP-OES As  Be  Cd  Co  Cr  Cu  Mo  Ni  Pb  V  Zn  JPP ÚKZÚZ, 30350.2; JPP ÚKZÚZ, 30500.2 Gleby, osady, osady denne Oznaczanie zawartosci wybranych pierwiastkow metoda ICP-OES Arsen (As)  Beryl (Be)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Molibden (Mo)  Nikiel (Ni)  Olow (Pb)  Wanad (V)  Cynk (Zn)  Pudy, kaly, sedimenty Stanoveni obsahu vybranych prvku metodou ICP-OES As  Be  Cd  Co  Cr  Cu  Mo  Ni  Pb  V  Zn  JPP UKZUZ, 30350.2; JPP UKZUZ, 30500.2","search_en":"Soil, sludge, sediments Determination of selected elements by ICP-OES method Arsenic (As)  Beryllium (Be)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Molybdenum (Mo)  Nickel (Ni)  Lead (Pb)  Vanadium (V)  Zinc (Zn)  JPP ÚKZÚZ, 30350.2; JPP ÚKZÚZ, 30500.2","search_zh":"土壤、污泥、沉积物 ICP-OES法测定选定元素含量 砷（As）  铍（Be）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  钼（Mo）  镍（Ni）  铅（Pb）  钒（V）  锌（Zn）  JPP ÚKZÚZ, 30350.2; JPP ÚKZÚZ, 30500.2","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":149,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d8938e920284072ba91edde1","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"11","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES","methodology_en":"Determination of selected elements by ICP-OES method","methodology_zh":"ICP-OES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou ICP-OES","parameters":[{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Sód (Na)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Siarka (S)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Sulphur (S)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"钠（Na）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"硫（S）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"S","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES\nZakres:\nGlin (Al)\nArsen (As)\nBor (B)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nSód (Na)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nSiarka (S)\nWanad (V)\nCynk (Zn)","reference":"JPP ÚKZÚZ, 20061.1; JPP ÚKZÚZ, 20062.1; JPP ÚKZÚZ, 20065.1; JPP ÚKZÚZ, 20155.1; JPP ÚKZÚZ, 20070.3","norm_bases":["JPP ÚKZÚZ, 20061.1","JPP ÚKZÚZ, 20062.1","JPP ÚKZÚZ, 20065.1","JPP ÚKZÚZ, 20155.1","JPP ÚKZÚZ, 20070.3"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Uszczegółowienie: wyraża się jako P2O5 lub P2O5 w suchej masie; jako K2O lub K2O w suchej masie; jako MgO lub MgO w suchej masie; jako CaO lub CaO w suchej masie; jako MgCO3 w suchej masie; jako CaO + MgO; jako CaCO3 + MgCO3, CaCO3 + MgCO3 w suchej masie; siarka siarczanowa jako SO32- lub SO42-","note_en":"Specification: Expressed as P2O5 or P2O5 in dry matter; Expressed as K2O or K2O in dry matter; Expressed as MgO or MgO in dry matter; Expressed as CaO or CaO in dry matter; Expressed as MgCO3 in dry matter; Expressed as CaO + MgO; Expressed as CaCO3 + MgCO3, CaCO3 + MgCO3 in dry matter; Expressed as follows: sulfatic sulfur as SO32- or SO42-","note_zh":"细化说明：以P2O5或干物质中P2O5表示；以K2O或干物质中K2O表示；以MgO或干物质中MgO表示；以CaO或干物质中CaO表示；以干物质中MgCO3表示；以CaO + MgO表示；以CaCO3 + MgCO3、干物质中CaCO3 + MgCO3表示；硫酸盐硫以SO32-或SO42-表示","note_cs":"Upřesnění: Vyjadřuje se jako P2O5 nebo P2O5 v sušině; Vyjadřuje se jako K2O nebo K2O v sušině; Vyjadřuje se jako MgO nebo MgO v sušině; Vyjadřuje se jako CaO nebo CaO v sušině; Vyjadřuje se jako MgCO3 v sušině; Vyjadřuje se jako CaO + MgO; Vyjadřuje se jako CaCO3 + MgCO3, CaCO3 + MgCO3 v sušině; Vyjadřuje se formou: síranová síra jako SO32- nebo SO42-","search_text":"Nawozy i surowce do ich produkcji Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES Glin (Al)  Arsen (As)  Bor (B)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sód (Na)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Siarka (S)  Wanad (V)  Cynk (Zn)  Hnojiva a suroviny pro jejich výrobu Stanovení obsahu vybraných prvků metodou ICP-OES Al  As  B  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Na  Ni  P  Pb  S  V  Zn  JPP ÚKZÚZ, 20061.1; JPP ÚKZÚZ, 20062.1; JPP ÚKZÚZ, 20065.1; JPP ÚKZÚZ, 20155.1; JPP ÚKZÚZ, 20070.3 Nawozy i surowce do ich produkcji Oznaczanie zawartosci wybranych pierwiastkow metoda ICP-OES Glin (Al)  Arsen (As)  Bor (B)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sod (Na)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Siarka (S)  Wanad (V)  Cynk (Zn)  Hnojiva a suroviny pro jejich vyrobu Stanoveni obsahu vybranych prvku metodou ICP-OES Al  As  B  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Na  Ni  P  Pb  S  V  Zn  JPP UKZUZ, 20061.1; JPP UKZUZ, 20062.1; JPP UKZUZ, 20065.1; JPP UKZUZ, 20155.1; JPP UKZUZ, 20070.3","search_en":"Fertilizers and raw materials for their production Determination of selected elements by ICP-OES method Aluminium (Al)  Arsenic (As)  Boron (B)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Sodium (Na)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Sulphur (S)  Vanadium (V)  Zinc (Zn)  JPP ÚKZÚZ, 20061.1; JPP ÚKZÚZ, 20062.1; JPP ÚKZÚZ, 20065.1; JPP ÚKZÚZ, 20155.1; JPP ÚKZÚZ, 20070.3","search_zh":"肥料及其生产原料 ICP-OES法测定选定元素含量 铝（Al）  砷（As）  硼（B）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  钼（Mo）  钠（Na）  镍（Ni）  磷（P）  铅（Pb）  硫（S）  钒（V）  锌（Zn）  JPP ÚKZÚZ, 20061.1; JPP ÚKZÚZ, 20062.1; JPP ÚKZÚZ, 20065.1; JPP ÚKZÚZ, 20155.1; JPP ÚKZÚZ, 20070.3","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":150,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3cd3227b76a2048550368962","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"12","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości siarki metodą ICP-OES","methodology_en":"Determination of sulphur by ICP-OES method","methodology_zh":"ICP-OES法测定硫含量","methodology_cs":"Stanovení obsahu síry metodou ICP-OES","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości siarki metodą ICP-OES","reference":"JPP ÚKZÚZ, 40030.1; JPP ÚKZÚZ, 40100.1","norm_bases":["JPP ÚKZÚZ, 40030.1","JPP ÚKZÚZ, 40100.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości siarki metodą ICP-OES Rostlinný materiál Stanovení obsahu síry metodou ICP-OES JPP ÚKZÚZ, 40030.1; JPP ÚKZÚZ, 40100.1 Material roslinny Oznaczanie zawartosci siarki metoda ICP-OES Rostlinny material Stanoveni obsahu siry metodou ICP-OES JPP UKZUZ, 40030.1; JPP UKZUZ, 40100.1","search_en":"Plant material Determination of sulphur by ICP-OES method JPP ÚKZÚZ, 40030.1; JPP ÚKZÚZ, 40100.1","search_zh":"植物材料 ICP-OES法测定硫含量 JPP ÚKZÚZ, 40030.1; JPP ÚKZÚZ, 40100.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":151,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1c50879d8c43b1d47975608f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"13","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES","methodology_en":"Determination of selected elements by ICP-OES method","methodology_zh":"ICP-OES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou ICP-OES","parameters":[{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Sód (Na)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"钼（Mo）","range":""},{"name":"锰（Mn）","range":""},{"name":"钠（Na）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mo","range":""},{"name":"Mn","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES\nZakres:\nGlin (Al)\nArsen (As)\nBor (B)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMolibden (Mo)\nMangan (Mn)\nSód (Na)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nWanad (V)\nCynk (Zn)","reference":"JPP ÚKZÚZ, 40034.1; JPP ÚKZÚZ, 40090.1; JPP ÚKZÚZ, 40100.1","norm_bases":["JPP ÚKZÚZ, 40034.1","JPP ÚKZÚZ, 40090.1","JPP ÚKZÚZ, 40100.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES Glin (Al)  Arsen (As)  Bor (B)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Molibden (Mo)  Mangan (Mn)  Sód (Na)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Wanad (V)  Cynk (Zn)  Rostlinný materiál Stanovení obsahu vybraných prvků metodou ICP-OES Al  As  B  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mo  Mn  Na  Ni  P  Pb  V  Zn  JPP ÚKZÚZ, 40034.1; JPP ÚKZÚZ, 40090.1; JPP ÚKZÚZ, 40100.1 Material roslinny Oznaczanie zawartosci wybranych pierwiastkow metoda ICP-OES Glin (Al)  Arsen (As)  Bor (B)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Molibden (Mo)  Mangan (Mn)  Sod (Na)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Wanad (V)  Cynk (Zn)  Rostlinny material Stanoveni obsahu vybranych prvku metodou ICP-OES Al  As  B  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mo  Mn  Na  Ni  P  Pb  V  Zn  JPP UKZUZ, 40034.1; JPP UKZUZ, 40090.1; JPP UKZUZ, 40100.1","search_en":"Plant material Determination of selected elements by ICP-OES method Aluminium (Al)  Arsenic (As)  Boron (B)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Molybdenum (Mo)  Manganese (Mn)  Sodium (Na)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Vanadium (V)  Zinc (Zn)  JPP ÚKZÚZ, 40034.1; JPP ÚKZÚZ, 40090.1; JPP ÚKZÚZ, 40100.1","search_zh":"植物材料 ICP-OES法测定选定元素含量 铝（Al）  砷（As）  硼（B）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  钼（Mo）  锰（Mn）  钠（Na）  镍（Ni）  磷（P）  铅（Pb）  钒（V）  锌（Zn）  JPP ÚKZÚZ, 40034.1; JPP ÚKZÚZ, 40090.1; JPP ÚKZÚZ, 40100.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":152,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"874db3acbb927ba110038b04","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"14","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES","methodology_en":"Determination of selected elements by ICP-OES method","methodology_zh":"ICP-OES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou ICP-OES","parameters":[{"name":"Glin (Al)","range":""},{"name":"Bor (B)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Siarka (S)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Aluminium (Al)","range":""},{"name":"Boron (B)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Sulphur (S)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"铝（Al）","range":""},{"name":"硼（B）","range":""},{"name":"钙（Ca）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"磷（P）","range":""},{"name":"硫（S）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"B","range":""},{"name":"Ca","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"P","range":""},{"name":"S","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES\nZakres:\nGlin (Al)\nBor (B)\nWapń (Ca)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nFosfor (P)\nSiarka (S)\nCynk (Zn)","reference":"JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30074.1","norm_bases":["JPP ÚKZÚZ, 30068.1","JPP ÚKZÚZ, 30074.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie zawartości wybranych pierwiastków metodą ICP-OES Glin (Al)  Bor (B)  Wapń (Ca)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Fosfor (P)  Siarka (S)  Cynk (Zn)  Půdy, kaly, sedimenty Stanovení obsahu vybraných prvků metodou ICP-OES Al  B  Ca  Cu  Fe  K  Mg  Mn  P  S  Zn  JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30074.1 Gleby, osady, osady denne Oznaczanie zawartosci wybranych pierwiastkow metoda ICP-OES Glin (Al)  Bor (B)  Wapn (Ca)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Fosfor (P)  Siarka (S)  Cynk (Zn)  Pudy, kaly, sedimenty Stanoveni obsahu vybranych prvku metodou ICP-OES Al  B  Ca  Cu  Fe  K  Mg  Mn  P  S  Zn  JPP UKZUZ, 30068.1; JPP UKZUZ, 30074.1","search_en":"Soil, sludge, sediments Determination of selected elements by ICP-OES method Aluminium (Al)  Boron (B)  Calcium (Ca)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Phosphorus (P)  Sulphur (S)  Zinc (Zn)  JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30074.1","search_zh":"土壤、污泥、沉积物 ICP-OES法测定选定元素含量 铝（Al）  硼（B）  钙（Ca）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  磷（P）  硫（S）  锌（Zn）  JPP ÚKZÚZ, 30068.1; JPP ÚKZÚZ, 30074.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":153,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9108835653428de0fc390c03","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"15","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości rtęci na aparacie AMA","methodology_en":"Determination of mercury using AMA instrument","methodology_zh":"AMA仪器测定汞含量","methodology_cs":"Stanovení obsahu rtuti na přístroji AMA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości rtęci na aparacie AMA","reference":"JPP ÚKZÚZ, 20110.1","norm_bases":["JPP ÚKZÚZ, 20110.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nawozy i surowce do ich produkcji Oznaczanie zawartości rtęci na aparacie AMA Hnojiva a suroviny pro jejich výrobu Stanovení obsahu rtuti na přístroji AMA JPP ÚKZÚZ, 20110.1 Nawozy i surowce do ich produkcji Oznaczanie zawartosci rteci na aparacie AMA Hnojiva a suroviny pro jejich vyrobu Stanoveni obsahu rtuti na pristroji AMA JPP UKZUZ, 20110.1","search_en":"Fertilizers and raw materials for their production Determination of mercury using AMA instrument JPP ÚKZÚZ, 20110.1","search_zh":"肥料及其生产原料 AMA仪器测定汞含量 JPP ÚKZÚZ, 20110.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":154,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5fd1686c4f807a6940b091b9","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"16","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości rtęci na aparacie AMA","methodology_en":"Determination of mercury using AMA instrument","methodology_zh":"AMA仪器测定汞含量","methodology_cs":"Stanovení obsahu rtuti na přístroji AMA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości rtęci na aparacie AMA","reference":"JPP ÚKZÚZ, 40190.1","norm_bases":["JPP ÚKZÚZ, 40190.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości rtęci na aparacie AMA Rostlinný materiál Stanovení obsahu rtuti na přístroji AMA JPP ÚKZÚZ, 40190.1 Material roslinny Oznaczanie zawartosci rteci na aparacie AMA Rostlinny material Stanoveni obsahu rtuti na pristroji AMA JPP UKZUZ, 40190.1","search_en":"Plant material Determination of mercury using AMA instrument JPP ÚKZÚZ, 40190.1","search_zh":"植物材料 AMA仪器测定汞含量 JPP ÚKZÚZ, 40190.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":155,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b6acc4cbafca9024df616c36","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"17","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie zawartości rtęci na aparacie AMA","methodology_en":"Determination of mercury using AMA instrument","methodology_zh":"AMA仪器测定汞含量","methodology_cs":"Stanovení obsahu rtuti na přístroji AMA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości rtęci na aparacie AMA","reference":"JPP ÚKZÚZ, 30460.1","norm_bases":["JPP ÚKZÚZ, 30460.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie zawartości rtęci na aparacie AMA Půdy, kaly, sedimenty Stanovení obsahu rtuti na přístroji AMA JPP ÚKZÚZ, 30460.1 Gleby, osady, osady denne Oznaczanie zawartosci rteci na aparacie AMA Pudy, kaly, sedimenty Stanoveni obsahu rtuti na pristroji AMA JPP UKZUZ, 30460.1","search_en":"Soil, sludge, sediments Determination of mercury using AMA instrument JPP ÚKZÚZ, 30460.1","search_zh":"土壤、污泥、沉积物 AMA仪器测定汞含量 JPP ÚKZÚZ, 30460.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":156,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8a34f2c5b7863fadd278ba3d","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"18","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości azotu amonowego miareczkowo","methodology_en":"Determination of ammonium nitrogen by titrimetric method","methodology_zh":"滴定法测定铵态氮含量","methodology_cs":"Stanovení obsahu amonného dusíku titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu amonowego miareczkowo","reference":"JPP ÚKZÚZ, 20130.1","norm_bases":["JPP ÚKZÚZ, 20130.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Uszczegółowienie: wyraża się jako N","note_en":"Specification: Expressed as N","note_zh":"细化说明：以N表示","note_cs":"Upřesnění: Vyjadřuje se jako N","search_text":"Nawozy i surowce do ich produkcji Oznaczanie zawartości azotu amonowego miareczkowo Hnojiva a suroviny pro jejich výrobu Stanovení obsahu amonného dusíku titračně JPP ÚKZÚZ, 20130.1 Nawozy i surowce do ich produkcji Oznaczanie zawartosci azotu amonowego miareczkowo Hnojiva a suroviny pro jejich vyrobu Stanoveni obsahu amonneho dusiku titracne JPP UKZUZ, 20130.1","search_en":"Fertilizers and raw materials for their production Determination of ammonium nitrogen by titrimetric method JPP ÚKZÚZ, 20130.1","search_zh":"肥料及其生产原料 滴定法测定铵态氮含量 JPP ÚKZÚZ, 20130.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":157,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ca128669a81babcd894810d1","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"19","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości azotu amidowego metodą spektrofotometryczną","methodology_en":"Determination of amidic nitrogen by spectrophotometric method","methodology_zh":"分光光度法测定酰胺态氮含量","methodology_cs":"Stanovení obsahu amidického dusíku spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu amidowego metodą spektrofotometryczną","reference":"JPP ÚKZÚZ, 20150.2","norm_bases":["JPP ÚKZÚZ, 20150.2"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Uszczegółowienie: wyraża się jako N","note_en":"Specification: Expressed as N","note_zh":"细化说明：以N表示","note_cs":"Upřesnění: Vyjadřuje se jako N","search_text":"Nawozy i surowce do ich produkcji Oznaczanie zawartości azotu amidowego metodą spektrofotometryczną Hnojiva a suroviny pro jejich výrobu Stanovení obsahu amidického dusíku spektrofotometricky JPP ÚKZÚZ, 20150.2 Nawozy i surowce do ich produkcji Oznaczanie zawartosci azotu amidowego metoda spektrofotometryczna Hnojiva a suroviny pro jejich vyrobu Stanoveni obsahu amidickeho dusiku spektrofotometricky JPP UKZUZ, 20150.2","search_en":"Fertilizers and raw materials for their production Determination of amidic nitrogen by spectrophotometric method JPP ÚKZÚZ, 20150.2","search_zh":"肥料及其生产原料 分光光度法测定酰胺态氮含量 JPP ÚKZÚZ, 20150.2","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":158,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ad1d2bf9c681dc3fb1de12f6","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"20","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości azotu azotanowego i amonowego wg Devardy miareczkowo","methodology_en":"Determination of nitrate and ammonium nitrogen pursuant to Devarda by titrimetric method","methodology_zh":"德瓦达法滴定测定硝态氮和铵态氮含量","methodology_cs":"Stanovení obsahu dusičnanového a amonného dusíku podle Devarda titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu azotanowego i amonowego wg Devardy miareczkowo","reference":"JPP ÚKZÚZ, 20131.1","norm_bases":["JPP ÚKZÚZ, 20131.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Uszczegółowienie: wyraża się jako N","note_en":"Specification: Expressed as N","note_zh":"细化说明：以N表示","note_cs":"Upřesnění: Vyjadřuje se jako N","search_text":"Nawozy i surowce do ich produkcji Oznaczanie zawartości azotu azotanowego i amonowego wg Devardy miareczkowo Hnojiva a suroviny pro jejich výrobu Stanovení obsahu dusičnanového a amonného dusíku podle Devarda titračně JPP ÚKZÚZ, 20131.1 Nawozy i surowce do ich produkcji Oznaczanie zawartosci azotu azotanowego i amonowego wg Devardy miareczkowo Hnojiva a suroviny pro jejich vyrobu Stanoveni obsahu dusicnanoveho a amonneho dusiku podle Devarda titracne JPP UKZUZ, 20131.1","search_en":"Fertilizers and raw materials for their production Determination of nitrate and ammonium nitrogen pursuant to Devarda by titrimetric method JPP ÚKZÚZ, 20131.1","search_zh":"肥料及其生产原料 德瓦达法滴定测定硝态氮和铵态氮含量 JPP ÚKZÚZ, 20131.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":159,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"914ac3b7b97fe6e2acf4697a","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"21","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości azotu całkowitego wg Jodlbauera miareczkowo","methodology_en":"Determination of total nitrogen pursuant to Jodlbauer by titrimetric method","methodology_zh":"Jodlbauer法滴定测定总氮含量","methodology_cs":"Stanovení obsahu celkového dusíku podle Jodlbauera titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu całkowitego wg Jodlbauera miareczkowo","reference":"JPP ÚKZÚZ, 20135.2","norm_bases":["JPP ÚKZÚZ, 20135.2"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Uszczegółowienie: wyraża się jako N lub jako N w suchej masie","note_en":"Specification: Expressed as N or as N in dry matter","note_zh":"细化说明：以N或干物质中N表示","note_cs":"Upřesnění: Vyjadřuje se jako N nebo jako N v sušině","search_text":"Nawozy i surowce do ich produkcji Oznaczanie zawartości azotu całkowitego wg Jodlbauera miareczkowo Hnojiva a suroviny pro jejich výrobu Stanovení obsahu celkového dusíku podle Jodlbauera titračně JPP ÚKZÚZ, 20135.2 Nawozy i surowce do ich produkcji Oznaczanie zawartosci azotu calkowitego wg Jodlbauera miareczkowo Hnojiva a suroviny pro jejich vyrobu Stanoveni obsahu celkoveho dusiku podle Jodlbauera titracne JPP UKZUZ, 20135.2","search_en":"Fertilizers and raw materials for their production Determination of total nitrogen pursuant to Jodlbauer by titrimetric method JPP ÚKZÚZ, 20135.2","search_zh":"肥料及其生产原料 Jodlbauer法滴定测定总氮含量 JPP ÚKZÚZ, 20135.2","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":160,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"904bb61123beec834aad0096","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"22","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości biuretu w moczniku metodą spektrofotometryczną","methodology_en":"Determination of biuret in urea by spectrophotometric method","methodology_zh":"分光光度法测定尿素中缩二脲含量","methodology_cs":"Stanovení obsahu biuretu v močovině spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości biuretu w moczniku metodą spektrofotometryczną","reference":"JPP ÚKZÚZ, 20151.1","norm_bases":["JPP ÚKZÚZ, 20151.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nawozy i surowce do ich produkcji Oznaczanie zawartości biuretu w moczniku metodą spektrofotometryczną Hnojiva a suroviny pro jejich výrobu Stanovení obsahu biuretu v močovině spektrofotometricky JPP ÚKZÚZ, 20151.1 Nawozy i surowce do ich produkcji Oznaczanie zawartosci biuretu w moczniku metoda spektrofotometryczna Hnojiva a suroviny pro jejich vyrobu Stanoveni obsahu biuretu v mocovine spektrofotometricky JPP UKZUZ, 20151.1","search_en":"Fertilizers and raw materials for their production Determination of biuret in urea by spectrophotometric method JPP ÚKZÚZ, 20151.1","search_zh":"肥料及其生产原料 分光光度法测定尿素中缩二脲含量 JPP ÚKZÚZ, 20151.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":161,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5c7d4681e1e75b0aa8be3cb8","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"23","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości popiołu i substancji palnych metodą wagową","methodology_en":"Determination of ash and combustible substances by gravimetric method","methodology_zh":"重量法测定灰分和可燃物含量","methodology_cs":"Stanovení obsahu popela a spalitelných látek gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości popiołu i substancji palnych metodą wagową","reference":"JPP ÚKZÚZ, 20010.1","norm_bases":["JPP ÚKZÚZ, 20010.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Uszczegółowienie: wyraża się jako: popiół, popiół w suchej masie, substancje palne w suchej masie","note_en":"Specification: Expressed as ash, ash in dry matter, combustible substances in dry matter","note_zh":"细化说明：表示形式：灰分、干物质中灰分、干物质中可燃物","note_cs":"Upřesnění: Vyjadřuje se formou: popel, popel v sušině, spalitelné látky v sušině","search_text":"Nawozy i surowce do ich produkcji Oznaczanie zawartości popiołu i substancji palnych metodą wagową Hnojiva a suroviny pro jejich výrobu Stanovení obsahu popela a spalitelných látek gravimetricky JPP ÚKZÚZ, 20010.1 Nawozy i surowce do ich produkcji Oznaczanie zawartosci popiolu i substancji palnych metoda wagowa Hnojiva a suroviny pro jejich vyrobu Stanoveni obsahu popela a spalitelnych latek gravimetricky JPP UKZUZ, 20010.1","search_en":"Fertilizers and raw materials for their production Determination of ash and combustible substances by gravimetric method JPP ÚKZÚZ, 20010.1","search_zh":"肥料及其生产原料 重量法测定灰分和可燃物含量 JPP ÚKZÚZ, 20010.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":162,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"68a5e3e7f679b8da7d6b56d1","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"24","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie wielkości cząstek metodą granulometryczną","methodology_en":"Determination of fineness of particles by granulometric method","methodology_zh":"粒度法测定颗粒大小","methodology_cs":"Stanovení velikosti částic granulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wielkości cząstek metodą granulometryczną","reference":"JPP ÚKZÚZ, 20231.1","norm_bases":["JPP ÚKZÚZ, 20231.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nawozy i surowce do ich produkcji Oznaczanie wielkości cząstek metodą granulometryczną Hnojiva a suroviny pro jejich výrobu Stanovení velikosti částic granulometricky JPP ÚKZÚZ, 20231.1 Nawozy i surowce do ich produkcji Oznaczanie wielkosci czastek metoda granulometryczna Hnojiva a suroviny pro jejich vyrobu Stanoveni velikosti castic granulometricky JPP UKZUZ, 20231.1","search_en":"Fertilizers and raw materials for their production Determination of fineness of particles by granulometric method JPP ÚKZÚZ, 20231.1","search_zh":"肥料及其生产原料 粒度法测定颗粒大小 JPP ÚKZÚZ, 20231.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":163,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"03000bb7f7b657588e784753","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"27","test_object":"Nawozy i surowce do ich produkcji","test_object_en":"Fertilizers and raw materials for their production","test_object_zh":"肥料及其生产原料","test_object_cs":"Hnojiva a suroviny pro jejich výrobu","methodology":"Oznaczanie przewodności elektrycznej metodą elektrochemiczną","methodology_en":"Determination of electric conductivity by electrochemical method","methodology_zh":"电化学法测定电导率","methodology_cs":"Stanovení elektrické vodivosti elektrochemicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej metodą elektrochemiczną","reference":"JPP ÚKZÚZ, 20030.1","norm_bases":["JPP ÚKZÚZ, 20030.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nawozy i surowce do ich produkcji Oznaczanie przewodności elektrycznej metodą elektrochemiczną Hnojiva a suroviny pro jejich výrobu Stanovení elektrické vodivosti elektrochemicky JPP ÚKZÚZ, 20030.1 Nawozy i surowce do ich produkcji Oznaczanie przewodnosci elektrycznej metoda elektrochemiczna Hnojiva a suroviny pro jejich vyrobu Stanoveni elektricke vodivosti elektrochemicky JPP UKZUZ, 20030.1","search_en":"Fertilizers and raw materials for their production Determination of electric conductivity by electrochemical method JPP ÚKZÚZ, 20030.1","search_zh":"肥料及其生产原料 电化学法测定电导率 JPP ÚKZÚZ, 20030.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":164,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1501d87d0024346af6df2cd6","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"28","test_object":"Gleby, osady, osady denne","test_object_en":"Soil, sludge, sediments","test_object_zh":"土壤、污泥、沉积物","test_object_cs":"Půdy, kaly, sedimenty","methodology":"Oznaczanie węgla i azotu metodą analizy elementarnej","methodology_en":"Determination of carbon and nitrogen by elemental analysis","methodology_zh":"元素分析法测定碳和氮","methodology_cs":"Stanovení uhlíku a dusíku elementární analýzou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węgla i azotu metodą analizy elementarnej","reference":"JPP ÚKZÚZ, 30995.1","norm_bases":["JPP ÚKZÚZ, 30995.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, osady, osady denne Oznaczanie węgla i azotu metodą analizy elementarnej Půdy, kaly, sedimenty Stanovení uhlíku a dusíku elementární analýzou JPP ÚKZÚZ, 30995.1 Gleby, osady, osady denne Oznaczanie wegla i azotu metoda analizy elementarnej Pudy, kaly, sedimenty Stanoveni uhliku a dusiku elementarni analyzou JPP UKZUZ, 30995.1","search_en":"Soil, sludge, sediments Determination of carbon and nitrogen by elemental analysis JPP ÚKZÚZ, 30995.1","search_zh":"土壤、污泥、沉积物 元素分析法测定碳和氮 JPP ÚKZÚZ, 30995.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":165,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"822a67599a1f388a7cb77a9f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"29","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie azotu całkowitego wg Dumasa","methodology_en":"Determination of total nitrogen pursuant to Dumas","methodology_zh":"杜马斯法测定总氮","methodology_cs":"Stanovení celkového dusíku podle Dumase","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu całkowitego wg Dumasa","reference":"JPP ÚKZÚZ, 40058.1","norm_bases":["JPP ÚKZÚZ, 40058.1"],"lab_section":"ÚKZÚZ, NRL, Dział NRL Pilzno","lab_section_en":"ÚKZÚZ, NRL, Department of NRL Plzeň","lab_section_zh":"ÚKZÚZ, NRL，NRL比尔森科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení NRL Plzeň","lab_address":"Slovanská alej 20, 326 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie azotu całkowitego wg Dumasa Rostlinný materiál Stanovení celkového dusíku podle Dumase JPP ÚKZÚZ, 40058.1 Material roslinny Oznaczanie azotu calkowitego wg Dumasa Rostlinny material Stanoveni celkoveho dusiku podle Dumase JPP UKZUZ, 40058.1","search_en":"Plant material Determination of total nitrogen pursuant to Dumas JPP ÚKZÚZ, 40058.1","search_zh":"植物材料 杜马斯法测定总氮 JPP ÚKZÚZ, 40058.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":166,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a651b6098182afb7238c3ef8","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"1","test_object":"Bulwy i łęty ziemniaka","test_object_en":"Potato tubers and haulm","test_object_zh":"马铃薯块茎和茎叶","test_object_cs":"Hlízy a nať brambor","methodology":"Badanie sadzeniaków i odmian ziemniaka na obecność wirusów metodą ELISA","methodology_en":"Testing of potato plants and varieties for the presence of viruses by ELISA method","methodology_zh":"ELISA法检测马铃薯种薯和品种中的病毒","methodology_cs":"Zkoušení sadby a odrůd brambor na přítomnost virů metodou ELISA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie sadzeniaków i odmian ziemniaka na obecność wirusów metodą ELISA","reference":"JPP ÚKZÚZ, 40310.1","norm_bases":["JPP ÚKZÚZ, 40310.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Oznaczane wirusy: LR, Y, A, X, M, S (Bioreba AG)","note_en":"Determined viruses: LR, Y, A, X, M, S (Bioreba AG)","note_zh":"测定病毒：LR、Y、A、X、M、S（Bioreba AG）","note_cs":"Stanovované viry: LR, Y, A, X, M, S (Bioereba AG)","search_text":"Bulwy i łęty ziemniaka Badanie sadzeniaków i odmian ziemniaka na obecność wirusów metodą ELISA Hlízy a nať brambor Zkoušení sadby a odrůd brambor na přítomnost virů metodou ELISA JPP ÚKZÚZ, 40310.1 Bulwy i lety ziemniaka Badanie sadzeniakow i odmian ziemniaka na obecnosc wirusow metoda ELISA Hlizy a nat brambor Zkouseni sadby a odrud brambor na pritomnost viru metodou ELISA JPP UKZUZ, 40310.1","search_en":"Potato tubers and haulm Testing of potato plants and varieties for the presence of viruses by ELISA method JPP ÚKZÚZ, 40310.1","search_zh":"马铃薯块茎和茎叶 ELISA法检测马铃薯种薯和品种中的病毒 JPP ÚKZÚZ, 40310.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":167,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"65fac11e44dd553b238be4c3","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"2","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP ÚKZÚZ, 10001.1","norm_bases":["JPP ÚKZÚZ, 10001.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Krmiva a suroviny pro jejich výrobu Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP ÚKZÚZ, 10001.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 10001.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of moisture by gravimetric method and calculation of dry matter JPP ÚKZÚZ, 10001.1","search_zh":"饲料及其生产原料 重量法测定水分含量并计算干物质 JPP ÚKZÚZ, 10001.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":168,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0c0dffa54ee719bfad00e4ac","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"3","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","methodology_en":"Determination of moisture by gravimetric method and calculation of dry matter","methodology_zh":"重量法测定水分含量并计算干物质","methodology_cs":"Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy","reference":"JPP ÚKZÚZ, 50010.1","norm_bases":["JPP ÚKZÚZ, 50010.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiał roślinny Oznaczanie zawartości wilgoci metodą wagową i obliczenie suchej masy Rostlinný materiál Stanovení obsahu vlhkosti gravimetricky a dopočet sušiny JPP ÚKZÚZ, 50010.1 Material roslinny Oznaczanie zawartosci wilgoci metoda wagowa i obliczenie suchej masy Rostlinny material Stanoveni obsahu vlhkosti gravimetricky a dopocet susiny JPP UKZUZ, 50010.1","search_en":"Plant material Determination of moisture by gravimetric method and calculation of dry matter JPP ÚKZÚZ, 50010.1","search_zh":"植物材料 重量法测定水分含量并计算干物质 JPP ÚKZÚZ, 50010.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":169,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c1a379d6a38dbee10a104e05","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"4","test_object":"Pasze i surowce do ich produkcji, materiał roślinny","test_object_en":"Animal feeding stuffs and raw materials for their production, plant material","test_object_zh":"饲料及其生产原料、植物材料","test_object_cs":"Krmiva a suroviny pro jejich výrobu, rostlinný materiál","methodology":"Oznaczanie zawartości azotu miareczkowo i substancji azotowych obliczeniowo z wyników pomiarów","methodology_en":"Determination of the content of nitrogen by titrimetric method and nitrogenous substances by calculation from measured values","methodology_zh":"滴定法测定氮含量并由测量值计算含氮物质","methodology_cs":"Stanovení obsahu dusíku titračně a dusíkatých látek výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości azotu miareczkowo i substancji azotowych obliczeniowo z wyników pomiarów","reference":"JPP ÚKZÚZ, 10014.1","norm_bases":["JPP ÚKZÚZ, 10014.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji, materiał roślinny Oznaczanie zawartości azotu miareczkowo i substancji azotowych obliczeniowo z wyników pomiarów Krmiva a suroviny pro jejich výrobu, rostlinný materiál Stanovení obsahu dusíku titračně a dusíkatých látek výpočtem z naměřených hodnot JPP ÚKZÚZ, 10014.1 Pasze i surowce do ich produkcji, material roslinny Oznaczanie zawartosci azotu miareczkowo i substancji azotowych obliczeniowo z wynikow pomiarow Krmiva a suroviny pro jejich vyrobu, rostlinny material Stanoveni obsahu dusiku titracne a dusikatych latek vypoctem z namerenych hodnot JPP UKZUZ, 10014.1","search_en":"Animal feeding stuffs and raw materials for their production, plant material Determination of the content of nitrogen by titrimetric method and nitrogenous substances by calculation from measured values JPP ÚKZÚZ, 10014.1","search_zh":"饲料及其生产原料、植物材料 滴定法测定氮含量并由测量值计算含氮物质 JPP ÚKZÚZ, 10014.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":170,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"12bbc416638761cff87990c0","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"5","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości tłuszczu metodą wagową","methodology_en":"Determination of fat by gravimetric method","methodology_zh":"重量法测定脂肪含量","methodology_cs":"Stanovení obsahu tuku gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości tłuszczu metodą wagową","reference":"JPP ÚKZÚZ, 10058.1","norm_bases":["JPP ÚKZÚZ, 10058.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości tłuszczu metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu tuku gravimetricky JPP ÚKZÚZ, 10058.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci tluszczu metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu tuku gravimetricky JPP UKZUZ, 10058.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of fat by gravimetric method JPP ÚKZÚZ, 10058.1","search_zh":"饲料及其生产原料 重量法测定脂肪含量 JPP ÚKZÚZ, 10058.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":171,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"221095d602a790eb0a18e5ed","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"6","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości tłuszczu w nasionach oleistych metodą wagową","methodology_en":"Determination of fat in oil seeds by gravimetric method","methodology_zh":"重量法测定油籽中脂肪含量","methodology_cs":"Stanovení obsahu tuku v olejnatých semenech gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości tłuszczu w nasionach oleistych metodą wagową","reference":"JPP ÚKZÚZ, 10060.1","norm_bases":["JPP ÚKZÚZ, 10060.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości tłuszczu w nasionach oleistych metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu tuku v olejnatých semenech gravimetricky JPP ÚKZÚZ, 10060.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci tluszczu w nasionach oleistych metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu tuku v olejnatych semenech gravimetricky JPP UKZUZ, 10060.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of fat in oil seeds by gravimetric method JPP ÚKZÚZ, 10060.1","search_zh":"饲料及其生产原料 重量法测定油籽中脂肪含量 JPP ÚKZÚZ, 10060.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":172,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f3065bc484d8fa416f608cf1","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"7","test_object":"Pasze i surowce do ich produkcji, materiał roślinny","test_object_en":"Animal feeding stuffs and raw materials for their production, plant material","test_object_zh":"饲料及其生产原料、植物材料","test_object_cs":"Krmiva a suroviny pro jejich výrobu, rostlinný materiál","methodology":"Oznaczanie zawartości włókna metodą wagową","methodology_en":"Determination of fibre by gravimetric method","methodology_zh":"重量法测定纤维含量","methodology_cs":"Stanovení obsahu vlákniny gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości włókna metodą wagową","reference":"JPP ÚKZÚZ, 10068.1","norm_bases":["JPP ÚKZÚZ, 10068.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji, materiał roślinny Oznaczanie zawartości włókna metodą wagową Krmiva a suroviny pro jejich výrobu, rostlinný materiál Stanovení obsahu vlákniny gravimetricky JPP ÚKZÚZ, 10068.1 Pasze i surowce do ich produkcji, material roslinny Oznaczanie zawartosci wlokna metoda wagowa Krmiva a suroviny pro jejich vyrobu, rostlinny material Stanoveni obsahu vlakniny gravimetricky JPP UKZUZ, 10068.1","search_en":"Animal feeding stuffs and raw materials for their production, plant material Determination of fibre by gravimetric method JPP ÚKZÚZ, 10068.1","search_zh":"饲料及其生产原料、植物材料 重量法测定纤维含量 JPP ÚKZÚZ, 10068.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":173,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a6291f9810fcffa04c45bc63","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"8","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości popiołu metodą wagową","methodology_en":"Determination of ash by gravimetric method","methodology_zh":"重量法测定灰分含量","methodology_cs":"Stanovení obsahu popele gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości popiołu metodą wagową","reference":"JPP ÚKZÚZ, 10004.1","norm_bases":["JPP ÚKZÚZ, 10004.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości popiołu metodą wagową Krmiva a suroviny pro jejich výrobu Stanovení obsahu popele gravimetricky JPP ÚKZÚZ, 10004.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci popiolu metoda wagowa Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu popele gravimetricky JPP UKZUZ, 10004.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of ash by gravimetric method JPP ÚKZÚZ, 10004.1","search_zh":"饲料及其生产原料 重量法测定灰分含量 JPP ÚKZÚZ, 10004.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":174,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2c4b3c303452e7b7f4179255","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"9","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości skrobi metodą polarymetryczną","methodology_en":"Determination of starch by polarimetric method","methodology_zh":"旋光法测定淀粉含量","methodology_cs":"Stanovení obsahu škrobu polarimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości skrobi metodą polarymetryczną","reference":"JPP ÚKZÚZ, 10083.1","norm_bases":["JPP ÚKZÚZ, 10083.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości skrobi metodą polarymetryczną Krmiva a suroviny pro jejich výrobu Stanovení obsahu škrobu polarimetricky JPP ÚKZÚZ, 10083.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci skrobi metoda polarymetryczna Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu skrobu polarimetricky JPP UKZUZ, 10083.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of starch by polarimetric method JPP ÚKZÚZ, 10083.1","search_zh":"饲料及其生产原料 旋光法测定淀粉含量 JPP ÚKZÚZ, 10083.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":175,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c6e7e941d87468b663fdc5e8","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"10","test_object":"Pasze i surowce do ich produkcji, materiał roślinny","test_object_en":"Animal feeding stuffs and raw materials for their production, plant material","test_object_zh":"饲料及其生产原料、植物材料","test_object_cs":"Krmiva a suroviny pro jejich výrobu, rostlinný materiál","methodology":"Oznaczanie zawartości cukrów miareczkowo","methodology_en":"Determination of sugars by titrimetric method","methodology_zh":"滴定法测定糖含量","methodology_cs":"Stanovení obsahu cukrů titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości cukrów miareczkowo","reference":"JPP ÚKZÚZ, 10084.1","norm_bases":["JPP ÚKZÚZ, 10084.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji, materiał roślinny Oznaczanie zawartości cukrów miareczkowo Krmiva a suroviny pro jejich výrobu, rostlinný materiál Stanovení obsahu cukrů titračně JPP ÚKZÚZ, 10084.1 Pasze i surowce do ich produkcji, material roslinny Oznaczanie zawartosci cukrow miareczkowo Krmiva a suroviny pro jejich vyrobu, rostlinny material Stanoveni obsahu cukru titracne JPP UKZUZ, 10084.1","search_en":"Animal feeding stuffs and raw materials for their production, plant material Determination of sugars by titrimetric method JPP ÚKZÚZ, 10084.1","search_zh":"饲料及其生产原料、植物材料 滴定法测定糖含量 JPP ÚKZÚZ, 10084.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":176,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7900f829553143884fc8f12c","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"11","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości fosforu całkowitego metodą spektrofotometryczną","methodology_en":"Determination of total phosphorus by spectrophotometric method","methodology_zh":"分光光度法测定总磷含量","methodology_cs":"Stanovení obsahu celkového fosforu spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości fosforu całkowitego metodą spektrofotometryczną","reference":"JPP ÚKZÚZ, 10128.1","norm_bases":["JPP ÚKZÚZ, 10128.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości fosforu całkowitego metodą spektrofotometryczną Krmiva a suroviny pro jejich výrobu Stanovení obsahu celkového fosforu spektrofotometricky JPP ÚKZÚZ, 10128.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci fosforu calkowitego metoda spektrofotometryczna Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu celkoveho fosforu spektrofotometricky JPP UKZUZ, 10128.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of total phosphorus by spectrophotometric method JPP ÚKZÚZ, 10128.1","search_zh":"饲料及其生产原料 分光光度法测定总磷含量 JPP ÚKZÚZ, 10128.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":177,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1a34e1ebecbae06a2882b456","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"12","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości chlorków rozpuszczalnych w wodzie jako chlorek sodu miareczkowo","methodology_en":"Determination of water-soluble chlorides as sodium chloride by titrimetric method","methodology_zh":"滴定法测定以氯化钠计的水溶性氯化物","methodology_cs":"Stanovení obsahu ve vodě rozpustných chloridů jako chlorid sodný titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości chlorków rozpuszczalnych w wodzie jako chlorek sodu miareczkowo","reference":"JPP ÚKZÚZ, 10129.1","norm_bases":["JPP ÚKZÚZ, 10129.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości chlorków rozpuszczalnych w wodzie jako chlorek sodu miareczkowo Krmiva a suroviny pro jejich výrobu Stanovení obsahu ve vodě rozpustných chloridů jako chlorid sodný titračně JPP ÚKZÚZ, 10129.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci chlorkow rozpuszczalnych w wodzie jako chlorek sodu miareczkowo Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu ve vode rozpustnych chloridu jako chlorid sodny titracne JPP UKZUZ, 10129.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of water-soluble chlorides as sodium chloride by titrimetric method JPP ÚKZÚZ, 10129.1","search_zh":"饲料及其生产原料 滴定法测定以氯化钠计的水溶性氯化物 JPP ÚKZÚZ, 10129.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":178,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"67db8362b3b2f9f4d227e396","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"13","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości aminokwasów metodą LC/UV","methodology_en":"Determination of amino acids by LC/UV method","methodology_zh":"LC/UV法测定氨基酸含量","methodology_cs":"Stanovení obsahu aminokyselin metodou LC/UV","parameters":[{"name":"Alanina","range":""},{"name":"arginina","range":""},{"name":"cystyna","range":""},{"name":"glicyna","range":""},{"name":"histydyna","range":""},{"name":"kwas asparaginowy","range":""},{"name":"kwas glutaminowy","range":""},{"name":"izoleucyna","range":""},{"name":"leucyna","range":""},{"name":"lizyna","range":""},{"name":"metionina","range":""},{"name":"fenyloalanina","range":""},{"name":"prolina","range":""},{"name":"seryna","range":""},{"name":"tauryna","range":""},{"name":"treonina","range":""},{"name":"tyrozyna","range":""},{"name":"walina","range":""}],"parameters_en":[{"name":"Alanine","range":""},{"name":"arginine","range":""},{"name":"cystine","range":""},{"name":"glycine","range":""},{"name":"histidine","range":""},{"name":"aspartic acid","range":""},{"name":"glutamic acid","range":""},{"name":"isoleucine","range":""},{"name":"leucine","range":""},{"name":"lysine","range":""},{"name":"methionine","range":""},{"name":"phenylalanine","range":""},{"name":"proline","range":""},{"name":"serine","range":""},{"name":"taurine","range":""},{"name":"threonine","range":""},{"name":"tyrosine","range":""},{"name":"valine","range":""}],"parameters_zh":[{"name":"丙氨酸","range":""},{"name":"精氨酸","range":""},{"name":"胱氨酸","range":""},{"name":"甘氨酸","range":""},{"name":"组氨酸","range":""},{"name":"天冬氨酸","range":""},{"name":"谷氨酸","range":""},{"name":"异亮氨酸","range":""},{"name":"亮氨酸","range":""},{"name":"赖氨酸","range":""},{"name":"蛋氨酸","range":""},{"name":"苯丙氨酸","range":""},{"name":"脯氨酸","range":""},{"name":"丝氨酸","range":""},{"name":"牛磺酸","range":""},{"name":"苏氨酸","range":""},{"name":"酪氨酸","range":""},{"name":"缬氨酸","range":""}],"parameters_cs":[{"name":"Alanin","range":""},{"name":"arginin","range":""},{"name":"cystin","range":""},{"name":"glycin","range":""},{"name":"histidin","range":""},{"name":"kyselina asparagová","range":""},{"name":"kyselina glutamová","range":""},{"name":"isoleucin","range":""},{"name":"leucin","range":""},{"name":"lysin","range":""},{"name":"methionin","range":""},{"name":"phenylalanin","range":""},{"name":"prolin","range":""},{"name":"serin","range":""},{"name":"taurin","range":""},{"name":"threonin","range":""},{"name":"tyrosin","range":""},{"name":"valin","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości aminokwasów metodą LC/UV\nZakres:\nAlanina\narginina\ncystyna\nglicyna\nhistydyna\nkwas asparaginowy\nkwas glutaminowy\nizoleucyna\nleucyna\nlizyna\nmetionina\nfenyloalanina\nprolina\nseryna\ntauryna\ntreonina\ntyrozyna\nwalina","reference":"JPP ÚKZÚZ, 10021.1; JPP ÚKZÚZ, 10024.1","norm_bases":["JPP ÚKZÚZ, 10021.1","JPP ÚKZÚZ, 10024.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości aminokwasów metodą LC/UV Alanina  arginina  cystyna  glicyna  histydyna  kwas asparaginowy  kwas glutaminowy  izoleucyna  leucyna  lizyna  metionina  fenyloalanina  prolina  seryna  tauryna  treonina  tyrozyna  walina  Krmiva a suroviny pro jejich výrobu Stanovení obsahu aminokyselin metodou LC/UV Alanin  arginin  cystin  glycin  histidin  kyselina asparagová  kyselina glutamová  isoleucin  leucin  lysin  methionin  phenylalanin  prolin  serin  taurin  threonin  tyrosin  valin  JPP ÚKZÚZ, 10021.1; JPP ÚKZÚZ, 10024.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci aminokwasow metoda LC/UV Alanina  arginina  cystyna  glicyna  histydyna  kwas asparaginowy  kwas glutaminowy  izoleucyna  leucyna  lizyna  metionina  fenyloalanina  prolina  seryna  tauryna  treonina  tyrozyna  walina  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu aminokyselin metodou LC/UV Alanin  arginin  cystin  glycin  histidin  kyselina asparagova  kyselina glutamova  isoleucin  leucin  lysin  methionin  phenylalanin  prolin  serin  taurin  threonin  tyrosin  valin  JPP UKZUZ, 10021.1; JPP UKZUZ, 10024.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of amino acids by LC/UV method Alanine  arginine  cystine  glycine  histidine  aspartic acid  glutamic acid  isoleucine  leucine  lysine  methionine  phenylalanine  proline  serine  taurine  threonine  tyrosine  valine  JPP ÚKZÚZ, 10021.1; JPP ÚKZÚZ, 10024.1","search_zh":"饲料及其生产原料 LC/UV法测定氨基酸含量 丙氨酸  精氨酸  胱氨酸  甘氨酸  组氨酸  天冬氨酸  谷氨酸  异亮氨酸  亮氨酸  赖氨酸  蛋氨酸  苯丙氨酸  脯氨酸  丝氨酸  牛磺酸  苏氨酸  酪氨酸  缬氨酸  JPP ÚKZÚZ, 10021.1; JPP ÚKZÚZ, 10024.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":179,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e20be71d4eeb184540e285bb","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"14","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą FAAS","methodology_en":"Determination of selected elements by FAAS method","methodology_zh":"FAAS法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou FAAS","parameters":[{"name":"Miedź (Cu)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Copper (Cu)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"铜（Cu）","range":""},{"name":"锰（Mn）","range":""},{"name":"铁（Fe）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Cu","range":""},{"name":"Mn","range":""},{"name":"Fe","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą FAAS\nZakres:\nMiedź (Cu)\nMangan (Mn)\nŻelazo (Fe)\nCynk (Zn)","reference":"JPP ÚKZÚZ, 10325.1","norm_bases":["JPP ÚKZÚZ, 10325.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wybranych pierwiastków metodą FAAS Miedź (Cu)  Mangan (Mn)  Żelazo (Fe)  Cynk (Zn)  Krmiva a suroviny pro jejich výrobu Stanovení obsahu vybraných prvků metodou FAAS Cu  Mn  Fe  Zn  JPP ÚKZÚZ, 10325.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wybranych pierwiastkow metoda FAAS Miedz (Cu)  Mangan (Mn)  Zelazo (Fe)  Cynk (Zn)  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vybranych prvku metodou FAAS Cu  Mn  Fe  Zn  JPP UKZUZ, 10325.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of selected elements by FAAS method Copper (Cu)  Manganese (Mn)  Iron (Fe)  Zinc (Zn)  JPP ÚKZÚZ, 10325.1","search_zh":"饲料及其生产原料 FAAS法测定选定元素含量 铜（Cu）  锰（Mn）  铁（Fe）  锌（Zn）  JPP ÚKZÚZ, 10325.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":180,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"269a7eef2d27905a6fd2ce47","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"15","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wybranych pierwiastków metodą FAAS/FAES","methodology_en":"Determination of selected elements by FAAS/FAES method","methodology_zh":"FAAS/FAES法测定选定元素含量","methodology_cs":"Stanovení obsahu vybraných prvků metodou FAAS/FAES","parameters":[{"name":"Sód (Na)","range":""},{"name":"Potas (K)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Magnez (Mg)","range":""}],"parameters_en":[{"name":"Sodium (Na)","range":""},{"name":"Potassium (K)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Magnesium (Mg)","range":""}],"parameters_zh":[{"name":"钠（Na）","range":""},{"name":"钾（K）","range":""},{"name":"钙（Ca）","range":""},{"name":"镁（Mg）","range":""}],"parameters_cs":[{"name":"Na","range":""},{"name":"K","range":""},{"name":"Ca","range":""},{"name":"Mg","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych pierwiastków metodą FAAS/FAES\nZakres:\nSód (Na)\nPotas (K)\nWapń (Ca)\nMagnez (Mg)","reference":"JPP ÚKZÚZ, 10135.1","norm_bases":["JPP ÚKZÚZ, 10135.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wybranych pierwiastków metodą FAAS/FAES Sód (Na)  Potas (K)  Wapń (Ca)  Magnez (Mg)  Krmiva a suroviny pro jejich výrobu Stanovení obsahu vybraných prvků metodou FAAS/FAES Na  K  Ca  Mg  JPP ÚKZÚZ, 10135.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wybranych pierwiastkow metoda FAAS/FAES Sod (Na)  Potas (K)  Wapn (Ca)  Magnez (Mg)  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vybranych prvku metodou FAAS/FAES Na  K  Ca  Mg  JPP UKZUZ, 10135.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of selected elements by FAAS/FAES method Sodium (Na)  Potassium (K)  Calcium (Ca)  Magnesium (Mg)  JPP ÚKZÚZ, 10135.1","search_zh":"饲料及其生产原料 FAAS/FAES法测定选定元素含量 钠（Na）  钾（K）  钙（Ca）  镁（Mg）  JPP ÚKZÚZ, 10135.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":181,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75e58b489e0e642a5021a1a9","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"16","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości witaminy A, E metodą HPLC/UV","methodology_en":"Determination of vitamin A, E by HPLC/UV method","methodology_zh":"HPLC/UV法测定维生素A、E含量","methodology_cs":"Stanovení obsahu vitaminu A, E metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości witaminy A, E metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10380.1","norm_bases":["JPP ÚKZÚZ, 10380.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości witaminy A, E metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení obsahu vitaminu A, E metodou HPLC/UV JPP ÚKZÚZ, 10380.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci witaminy A, E metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vitaminu A, E metodou HPLC/UV JPP UKZUZ, 10380.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of vitamin A, E by HPLC/UV method JPP ÚKZÚZ, 10380.1","search_zh":"饲料及其生产原料 HPLC/UV法测定维生素A、E含量 JPP ÚKZÚZ, 10380.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":182,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75928f7949286aea70a2756e","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"17","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie robenidyny i nikarbazyny metodą HPLC/UV","methodology_en":"Determination of robenidin and nicarbazin by HPLC/UV method","methodology_zh":"HPLC/UV法测定罗贝胍和尼卡巴嗪","methodology_cs":"Stanovení robenidinu a nikarbazinu metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie robenidyny i nikarbazyny metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10390.1; JPP ÚKZÚZ, 10360.1","norm_bases":["JPP ÚKZÚZ, 10390.1","JPP ÚKZÚZ, 10360.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie robenidyny i nikarbazyny metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení robenidinu a nikarbazinu metodou HPLC/UV JPP ÚKZÚZ, 10390.1; JPP ÚKZÚZ, 10360.1 Pasze i surowce do ich produkcji Oznaczanie robenidyny i nikarbazyny metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni robenidinu a nikarbazinu metodou HPLC/UV JPP UKZUZ, 10390.1; JPP UKZUZ, 10360.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of robenidin and nicarbazin by HPLC/UV method JPP ÚKZÚZ, 10390.1; JPP ÚKZÚZ, 10360.1","search_zh":"饲料及其生产原料 HPLC/UV法测定罗贝胍和尼卡巴嗪 JPP ÚKZÚZ, 10390.1; JPP ÚKZÚZ, 10360.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":183,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d8cf99ca49a0d7a0d02dbd38","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"18","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości wybranych dodatków paszowych metodą HPLC/UV","methodology_en":"Determination of selected feed additives by HPLC/UV method","methodology_zh":"HPLC/UV法测定选定饲料添加剂含量","methodology_cs":"Stanovení obsahu vybraných doplňkových látek metodou HPLC/UV","parameters":[{"name":"Monenzyna","range":""},{"name":"salinomycyna","range":""},{"name":"narazyna","range":""}],"parameters_en":[{"name":"Monensin","range":""},{"name":"salinomycin","range":""},{"name":"narasin","range":""}],"parameters_zh":[{"name":"莫能菌素","range":""},{"name":"盐霉素","range":""},{"name":"甲基盐霉素","range":""}],"parameters_cs":[{"name":"Monensin","range":""},{"name":"salinomycin","range":""},{"name":"narasin","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości wybranych dodatków paszowych metodą HPLC/UV\nZakres:\nMonenzyna\nsalinomycyna\nnarazyna","reference":"JPP ÚKZÚZ, 10350.1","norm_bases":["JPP ÚKZÚZ, 10350.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości wybranych dodatków paszowych metodą HPLC/UV Monenzyna  salinomycyna  narazyna  Krmiva a suroviny pro jejich výrobu Stanovení obsahu vybraných doplňkových látek metodou HPLC/UV Monensin  salinomycin  narasin  JPP ÚKZÚZ, 10350.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci wybranych dodatkow paszowych metoda HPLC/UV Monenzyna  salinomycyna  narazyna  Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu vybranych doplnkovych latek metodou HPLC/UV Monensin  salinomycin  narasin  JPP UKZUZ, 10350.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of selected feed additives by HPLC/UV method Monensin  salinomycin  narasin  JPP ÚKZÚZ, 10350.1","search_zh":"饲料及其生产原料 HPLC/UV法测定选定饲料添加剂含量 莫能菌素  盐霉素  甲基盐霉素  JPP ÚKZÚZ, 10350.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":184,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3c448516f5bff40853ccec81","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"19","test_object":"Nasiona roślin oleistych, pasze i surowce do ich produkcji","test_object_en":"Oil seeds, animal feeding stuffs and raw materials for their production","test_object_zh":"油料种子、饲料及其生产原料","test_object_cs":"Osivo olejnin, krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości kwasów tłuszczowych w tłuszczach i olejach metodą GC/FID","methodology_en":"Determination of fatty acids in fats and oils by GC/FID method","methodology_zh":"GC/FID法测定油脂中脂肪酸含量","methodology_cs":"Stanovení obsahu mastných kyselin v tucích a olejích metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości kwasów tłuszczowych w tłuszczach i olejach metodą GC/FID","reference":"JPP ÚKZÚZ, 10040.1","norm_bases":["JPP ÚKZÚZ, 10040.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":"Oznaczane anality: kwas kapronowy (C6:0), kaprylowy (C8:0), kaprynowy (C10:0), undekanowy (C11:0), laurynowy (C12:0), tridekanowy (C13:0), mirystynowy (C14:0), mirystoleinowy (C14:1), pentadekanowy (C15:0), cis-10-pentadecenowy (C15:1), palmitynowy (C16:0), palmitoleinowy (C16:1), heptadekanowy (C17:0), cis-10-heptadecenowy (C17:1), stearynowy (C18:0), trans-9-elaidynowy (C18:1), cis-9-oleinowy (C18:1), trans,trans-9,12-linoleladynowy (C18:2), cis,cis-9,12-linolowy (C18:2), arachidowy (C20:0), all cis-6,9,12-γ-linolenowy (C18:3), cis-9-gadoleinowy (C20:1), cis-11-gondoinowy (C20:1), all cis-9,12,15-α-linolenowy (C18:3), heneikozanowy (C21:0), cis-11,14-eikozadienowy (C20:2), behenowy (C22:0), all cis-8,11,14-eikozatrienowy (C20:3), cis-13-erukowy (C22:1), all cis-5,8,11,14-arachidonowy (C20:4), trikozanowy (C23:0), cis,cis-13,16-dokozadienowy (C22:2), lignocerynowy (C24:0), all cis-5,8,11,14,17-eikozapentaenowy (EPA, C20:5), cis-15-nerwonowy (C24:1), all cis-4,7,10,13,16,19-dokozaheksaenowy (DHA, C22:6)","note_en":"Determined analytes: Capronic acid (C6:0), caprylic acid (C8:0), capric acid (C10:0), undecanoic acid (C11:0), lauric acid (C12:0), tridecanoic acid (C13:0), myristic acid (C14:0), myristoleic acid (C14:1), pentadecanoic acid (C15:0), cis-10-pentadecenoic acid (C15:1), palmitic acid (C16:0), palmitoleic acid (C16:1), heptadecanoic acid (C17:0), cis-10-heptadecenoic acid (C17:1), stearic acid (C18:0), trans-9-elaidic acid (C18:1), cis-9-oleic acid (C18:1), trans,trans-9,12-linolelaidic acid (C18:2), cis,cis-9,12-linoleic acid (C18:2), arachic acid (C20:0), all cis-6,9,12-γ-linolenic acid (C18:3), cis-9-gadoleic acid (C20:1), cis-11-gondoic acid (C20:1), all cis-9,12,15-α-linolenic acid (C18:3), heneicosanoic acid (C21:0), cis-11,14-eicosadienoic acid (C20:2), behenic acid (C22:0), all cis-8,11,14-eicosatrienoic acid (C20:3), cis-13-erucic acid (C22:1), all cis-5,8,11,14-arachidonic acid (C20:4), tricosanoic acid (C23:0), cis,cis-13,16-docosadienoic acid (C22:2), lignoceric acid (C24:0), all cis-5,8,11,14,17-eicosapentaenoic acid (EPA, C20:5), cis-15-nervonic acid (C24:1), all cis-4,7,10,13,16,19-docosahexaenoic acid (DHA, C22:6)","note_zh":"测定分析物：己酸（C6:0）、辛酸（C8:0）、癸酸（C10:0）、十一烷酸（C11:0）、月桂酸（C12:0）、十三烷酸（C13:0）、肉豆蔻酸（C14:0）、肉豆蔻油酸（C14:1）、十五烷酸（C15:0）、顺-10-十五碳烯酸（C15:1）、棕榈酸（C16:0）、棕榈油酸（C16:1）、十七烷酸（C17:0）、顺-10-十七碳烯酸（C17:1）、硬脂酸（C18:0）、反-9-反油酸（C18:1）、顺-9-油酸（C18:1）、反,反-9,12-亚油反油酸（C18:2）、顺,顺-9,12-亚油酸（C18:2）、花生酸（C20:0）、全顺-6,9,12-γ-亚麻酸（C18:3）、顺-9-鳕油酸（C20:1）、顺-11-二十碳烯酸（C20:1）、全顺-9,12,15-α-亚麻酸（C18:3）、二十一烷酸（C21:0）、顺-11,14-二十碳二烯酸（C20:2）、山嵛酸（C22:0）、全顺-8,11,14-二十碳三烯酸（C20:3）、顺-13-芥酸（C22:1）、全顺-5,8,11,14-花生四烯酸（C20:4）、二十三烷酸（C23:0）、顺,顺-13,16-二十二碳二烯酸（C22:2）、木蜡酸（C24:0）、全顺-5,8,11,14,17-二十碳五烯酸（EPA，C20:5）、顺-15-神经酸（C24:1）、全顺-4,7,10,13,16,19-二十二碳六烯酸（DHA，C22:6）","note_cs":"Stanovované analyty: Kapronová (C6:0), kaprylová (C8:0), kaprinová (C10:0), undekanová (C11:0), laurová (C12:0), tridekanová (C13:0), myristová (C14:0), myristoolejová (C14:1), pentadekanová (C15:0), cis-10-pentadecenová (C15:1), palmitová (C16:0), palmitoolejová (C16:1), heptadekanová (C17:0), cis-10-heptadecenová (C17:1), stearová (C18:0), trans-9-elaidová (C18:1), cis-9-olejová (C18:1), trans,trans 9,12-linolelaidová (C18:2), cis,cis-9,12-linolová (C18:2), arachová (C20:0), all cis-6,9,12-γ linolenová (C18:3), cis-9-gadolejová (C20:1), cis-11-gondová (C20:1), all cis-9,12,15-α linolenová (C18:3), heneikosanová (C21:0), cis-11,14-eikosadienová (C20:2), behenová (C22:0), all cis-8,11,14-eikosatrienová (C20:3), cis-13-eruková (C22:1), all cis-5,8,11,14-arachidonová (C20:4), trikosanová (C23:0), cis,cis-13,16-dokosadienová (C22:2), lignocerová (C24:0), all cis-5,8,11,14,17-eikosapentaenová (EPA, C20:5), cis-15-nervonová (C24:1), all cis-4,7,10,13,16, 19- dokosahexaenová (DHA, C22:6)","search_text":"Nasiona roślin oleistych, pasze i surowce do ich produkcji Oznaczanie zawartości kwasów tłuszczowych w tłuszczach i olejach metodą GC/FID Osivo olejnin, krmiva a suroviny pro jejich výrobu Stanovení obsahu mastných kyselin v tucích a olejích metodou GC/FID JPP ÚKZÚZ, 10040.1 Nasiona roslin oleistych, pasze i surowce do ich produkcji Oznaczanie zawartosci kwasow tluszczowych w tluszczach i olejach metoda GC/FID Osivo olejnin, krmiva a suroviny pro jejich vyrobu Stanoveni obsahu mastnych kyselin v tucich a olejich metodou GC/FID JPP UKZUZ, 10040.1","search_en":"Oil seeds, animal feeding stuffs and raw materials for their production Determination of fatty acids in fats and oils by GC/FID method JPP ÚKZÚZ, 10040.1","search_zh":"油料种子、饲料及其生产原料 GC/FID法测定油脂中脂肪酸含量 JPP ÚKZÚZ, 10040.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":185,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9672937d2f8266a391908939","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"20","test_object":"Nasiona rzepaku i produkty ich przetwórstwa","test_object_en":"Rape seeds and products of their processing","test_object_zh":"油菜籽及其加工产品","test_object_cs":"Semeno řepky a produkty jeho zpracování","methodology":"Oznaczanie zawartości glukozynolanów metodą HPLC/UV","methodology_en":"Determination of glucosinolates by HPLC/UV method","methodology_zh":"HPLC/UV法测定硫代葡萄糖苷含量","methodology_cs":"Stanovení obsahu glukosinolátů metodou HPLC/UV","parameters":[{"name":"Glukorafanina","range":""},{"name":"glukotropeolina","range":""},{"name":"glukoiberyna","range":""},{"name":"progoitryna","range":""},{"name":"epiprogoitryna","range":""},{"name":"synigryna","range":""},{"name":"glukonapoleiferyna","range":""},{"name":"glukoalisyna","range":""},{"name":"glukonapina","range":""},{"name":"4-hydroksyglukobrasycyna","range":""},{"name":"glukobrasykanapina","range":""},{"name":"4-metoksyglukobrasycyna","range":""},{"name":"glukonasturcyna","range":""},{"name":"glukoneobrasycyna","range":""},{"name":"glukobrasycyna","range":""}],"parameters_en":[{"name":"Glucoraphanin","range":""},{"name":"glucotropaeolin","range":""},{"name":"glucoiberin","range":""},{"name":"progoitrin","range":""},{"name":"epiprogoitrin","range":""},{"name":"sinigrin","range":""},{"name":"gluconapoleiferin","range":""},{"name":"glucoalyssin","range":""},{"name":"gluconapin","range":""},{"name":"4-hydroxyglucobrassicin","range":""},{"name":"glucobrassicanapin","range":""},{"name":"4-methoxyglucobrassicin","range":""},{"name":"gluconasturtiin","range":""},{"name":"gluconeobrassicin","range":""},{"name":"glucobrassicin","range":""}],"parameters_zh":[{"name":"萝卜硫苷","range":""},{"name":"旱金莲苷","range":""},{"name":"屈曲花苷","range":""},{"name":"前致甲状腺肿素","range":""},{"name":"表前致甲状腺肿素","range":""},{"name":"黑芥子苷","range":""},{"name":"芸薹葡糖硫苷","range":""},{"name":"庭荠苷","range":""},{"name":"葡萄糖芫菁芥素","range":""},{"name":"4-羟基芸苔葡糖硫苷","range":""},{"name":"芸薹葡萄糖苷","range":""},{"name":"4-甲氧基芸苔葡糖硫苷","range":""},{"name":"豆瓣菜苷","range":""},{"name":"新芸苔葡糖硫苷","range":""},{"name":"芸苔葡糖硫苷","range":""}],"parameters_cs":[{"name":"Glukorafanin","range":""},{"name":"glukotropaeolin","range":""},{"name":"glukoiberin","range":""},{"name":"progoitrin","range":""},{"name":"epiprogoitrin","range":""},{"name":"sinigrin","range":""},{"name":"glukonapoleiferin","range":""},{"name":"glukoalyssin","range":""},{"name":"glukonapin","range":""},{"name":"4 - hydroxyglukobrassicin","range":""},{"name":"glukobrassikanapin","range":""},{"name":"4 - methoxyglukobrassicin","range":""},{"name":"glukonasturtiin","range":""},{"name":"glukoneobrassicin","range":""},{"name":"glukobrassicin","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości glukozynolanów metodą HPLC/UV\nZakres:\nGlukorafanina\nglukotropeolina\nglukoiberyna\nprogoitryna\nepiprogoitryna\nsynigryna\nglukonapoleiferyna\nglukoalisyna\nglukonapina\n4-hydroksyglukobrasycyna\nglukobrasykanapina\n4-metoksyglukobrasycyna\nglukonasturcyna\nglukoneobrasycyna\nglukobrasycyna","reference":"JPP ÚKZÚZ, 10540.1","norm_bases":["JPP ÚKZÚZ, 10540.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Nasiona rzepaku i produkty ich przetwórstwa Oznaczanie zawartości glukozynolanów metodą HPLC/UV Glukorafanina  glukotropeolina  glukoiberyna  progoitryna  epiprogoitryna  synigryna  glukonapoleiferyna  glukoalisyna  glukonapina  4-hydroksyglukobrasycyna  glukobrasykanapina  4-metoksyglukobrasycyna  glukonasturcyna  glukoneobrasycyna  glukobrasycyna  Semeno řepky a produkty jeho zpracování Stanovení obsahu glukosinolátů metodou HPLC/UV Glukorafanin  glukotropaeolin  glukoiberin  progoitrin  epiprogoitrin  sinigrin  glukonapoleiferin  glukoalyssin  glukonapin  4 - hydroxyglukobrassicin  glukobrassikanapin  4 - methoxyglukobrassicin  glukonasturtiin  glukoneobrassicin  glukobrassicin  JPP ÚKZÚZ, 10540.1 Nasiona rzepaku i produkty ich przetworstwa Oznaczanie zawartosci glukozynolanow metoda HPLC/UV Glukorafanina  glukotropeolina  glukoiberyna  progoitryna  epiprogoitryna  synigryna  glukonapoleiferyna  glukoalisyna  glukonapina  4-hydroksyglukobrasycyna  glukobrasykanapina  4-metoksyglukobrasycyna  glukonasturcyna  glukoneobrasycyna  glukobrasycyna  Semeno repky a produkty jeho zpracovani Stanoveni obsahu glukosinolatu metodou HPLC/UV Glukorafanin  glukotropaeolin  glukoiberin  progoitrin  epiprogoitrin  sinigrin  glukonapoleiferin  glukoalyssin  glukonapin  4 - hydroxyglukobrassicin  glukobrassikanapin  4 - methoxyglukobrassicin  glukonasturtiin  glukoneobrassicin  glukobrassicin  JPP UKZUZ, 10540.1","search_en":"Rape seeds and products of their processing Determination of glucosinolates by HPLC/UV method Glucoraphanin  glucotropaeolin  glucoiberin  progoitrin  epiprogoitrin  sinigrin  gluconapoleiferin  glucoalyssin  gluconapin  4-hydroxyglucobrassicin  glucobrassicanapin  4-methoxyglucobrassicin  gluconasturtiin  gluconeobrassicin  glucobrassicin  JPP ÚKZÚZ, 10540.1","search_zh":"油菜籽及其加工产品 HPLC/UV法测定硫代葡萄糖苷含量 萝卜硫苷  旱金莲苷  屈曲花苷  前致甲状腺肿素  表前致甲状腺肿素  黑芥子苷  芸薹葡糖硫苷  庭荠苷  葡萄糖芫菁芥素  4-羟基芸苔葡糖硫苷  芸薹葡萄糖苷  4-甲氧基芸苔葡糖硫苷  豆瓣菜苷  新芸苔葡糖硫苷  芸苔葡糖硫苷  JPP ÚKZÚZ, 10540.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":186,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fe76dbe3c0de261ca789424d","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"21","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości arsenu metodą HG-AAS","methodology_en":"Determination of arsenic by HG-AAS method","methodology_zh":"HG-AAS法测定砷含量","methodology_cs":"Stanovení obsahu arsenu metodou atomové HG-AAS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości arsenu metodą HG-AAS","reference":"JPP ÚKZÚZ, 10430.1","norm_bases":["JPP ÚKZÚZ, 10430.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości arsenu metodą HG-AAS Krmiva a suroviny pro jejich výrobu Stanovení obsahu arsenu metodou atomové HG-AAS JPP ÚKZÚZ, 10430.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci arsenu metoda HG-AAS Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu arsenu metodou atomove HG-AAS JPP UKZUZ, 10430.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of arsenic by HG-AAS method JPP ÚKZÚZ, 10430.1","search_zh":"饲料及其生产原料 HG-AAS法测定砷含量 JPP ÚKZÚZ, 10430.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":187,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f6512d3e7497a194a3061569","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"22","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości kadmu i ołowiu metodą FAAS","methodology_en":"Determination of cadmium and lead by FAAS method","methodology_zh":"FAAS法测定镉和铅含量","methodology_cs":"Stanovení obsahu kadmia a olova metodou FAAS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości kadmu i ołowiu metodą FAAS","reference":"JPP ÚKZÚZ, 10450.1","norm_bases":["JPP ÚKZÚZ, 10450.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości kadmu i ołowiu metodą FAAS Krmiva a suroviny pro jejich výrobu Stanovení obsahu kadmia a olova metodou FAAS JPP ÚKZÚZ, 10450.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci kadmu i olowiu metoda FAAS Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu kadmia a olova metodou FAAS JPP UKZUZ, 10450.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of cadmium and lead by FAAS method JPP ÚKZÚZ, 10450.1","search_zh":"饲料及其生产原料 FAAS法测定镉和铅含量 JPP ÚKZÚZ, 10450.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":188,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"acb955637f313c18f41a4aa5","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"23","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości rtęci metodą spektrofotometryczną","methodology_en":"Determination of mercury by spectrophotometric method","methodology_zh":"分光光度法测定汞含量","methodology_cs":"Stanovení obsahu rtuti spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości rtęci metodą spektrofotometryczną","reference":"JPP ÚKZÚZ, 10420.1","norm_bases":["JPP ÚKZÚZ, 10420.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości rtęci metodą spektrofotometryczną Krmiva a suroviny pro jejich výrobu Stanovení obsahu rtuti spektrofotometricky JPP ÚKZÚZ, 10420.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci rteci metoda spektrofotometryczna Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu rtuti spektrofotometricky JPP UKZUZ, 10420.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of mercury by spectrophotometric method JPP ÚKZÚZ, 10420.1","search_zh":"饲料及其生产原料 分光光度法测定汞含量 JPP ÚKZÚZ, 10420.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":189,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c8942725ef0a363ed0aba544","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"24","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie aktywności fitazy metodą spektrofotometryczną","methodology_en":"Determination of phytase activity by spectrophotometric method","methodology_zh":"分光光度法测定植酸酶活性","methodology_cs":"Stanovení aktivity fytázy spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie aktywności fitazy metodą spektrofotometryczną","reference":"JPP ÚKZÚZ, 10100.1","norm_bases":["JPP ÚKZÚZ, 10100.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie aktywności fitazy metodą spektrofotometryczną Krmiva a suroviny pro jejich výrobu Stanovení aktivity fytázy spektrofotometricky JPP ÚKZÚZ, 10100.1 Pasze i surowce do ich produkcji Oznaczanie aktywnosci fitazy metoda spektrofotometryczna Krmiva a suroviny pro jejich vyrobu Stanoveni aktivity fytazy spektrofotometricky JPP UKZUZ, 10100.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of phytase activity by spectrophotometric method JPP ÚKZÚZ, 10100.1","search_zh":"饲料及其生产原料 分光光度法测定植酸酶活性 JPP ÚKZÚZ, 10100.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":190,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"29d703a48f3a7cbe2deb86a4","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"25","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości tryptofanu całkowitego i wolnego metodą HPLC/FLD","methodology_en":"Determination of total and free tryptophan by HPLC/FLD method","methodology_zh":"HPLC/FLD法测定总色氨酸和游离色氨酸含量","methodology_cs":"Stanovení obsahu celkového a volného tryptofanu metodou HPLC/FLD","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości tryptofanu całkowitego i wolnego metodą HPLC/FLD","reference":"JPP ÚKZÚZ, 10023.2","norm_bases":["JPP ÚKZÚZ, 10023.2"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości tryptofanu całkowitego i wolnego metodą HPLC/FLD Krmiva a suroviny pro jejich výrobu Stanovení obsahu celkového a volného tryptofanu metodou HPLC/FLD JPP ÚKZÚZ, 10023.2 Pasze i surowce do ich produkcji Oznaczanie zawartosci tryptofanu calkowitego i wolnego metoda HPLC/FLD Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu celkoveho a volneho tryptofanu metodou HPLC/FLD JPP UKZUZ, 10023.2","search_en":"Animal feeding stuffs and raw materials for their production Determination of total and free tryptophan by HPLC/FLD method JPP ÚKZÚZ, 10023.2","search_zh":"饲料及其生产原料 HPLC/FLD法测定总色氨酸和游离色氨酸含量 JPP ÚKZÚZ, 10023.2","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":191,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d2a5a42a20ceb8b64e04d842","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"26","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Oznaczanie zawartości hydroksyanalogu metioniny metodą HPLC/UV","methodology_en":"Determination of methionine hydroxy analogue by HPLC/UV method","methodology_zh":"HPLC/UV法测定蛋氨酸羟基类似物含量","methodology_cs":"Stanovení obsahu hydroxyanalogu methioninu metodou HPLC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości hydroksyanalogu metioniny metodą HPLC/UV","reference":"JPP ÚKZÚZ, 10330.1","norm_bases":["JPP ÚKZÚZ, 10330.1"],"lab_section":"ÚKZÚZ, NRL, Dział Specjalnych Analiz Roślin i Pasz","lab_section_en":"ÚKZÚZ, NRL, Department of Special Plant and Feed Analysis","lab_section_zh":"ÚKZÚZ, NRL，植物和饲料专项分析科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení speciálních analýz rostlin a krmiv","lab_address":"Lípa 121, 582 57 Lípa","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasze i surowce do ich produkcji Oznaczanie zawartości hydroksyanalogu metioniny metodą HPLC/UV Krmiva a suroviny pro jejich výrobu Stanovení obsahu hydroxyanalogu methioninu metodou HPLC/UV JPP ÚKZÚZ, 10330.1 Pasze i surowce do ich produkcji Oznaczanie zawartosci hydroksyanalogu metioniny metoda HPLC/UV Krmiva a suroviny pro jejich vyrobu Stanoveni obsahu hydroxyanalogu methioninu metodou HPLC/UV JPP UKZUZ, 10330.1","search_en":"Animal feeding stuffs and raw materials for their production Determination of methionine hydroxy analogue by HPLC/UV method JPP ÚKZÚZ, 10330.1","search_zh":"饲料及其生产原料 HPLC/UV法测定蛋氨酸羟基类似物含量 JPP ÚKZÚZ, 10330.1","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":192,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a1accc25c199c50fbc60a156","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"1","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Wykrywanie obecności GMO metodą PCR","methodology_en":"Detection of GMO by PCR method","methodology_zh":"PCR法检测转基因生物","methodology_cs":"Stanovení přítomnosti GMO metodou PCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie obecności GMO metodą PCR","reference":"JPP ÚKZÚZ, 60071.1; JPP ÚKZÚZ, 10251.1; JPP ÚKZÚZ, 10252.1; JPP ÚKZÚZ, 10253.1; JPP ÚKZÚZ, 10700.1; JPP ÚKZÚZ, 10254.1; JPP ÚKZÚZ, 10255.1; JPP ÚKZÚZ, 10257.1; JPP ÚKZÚZ, 10258.1; JPP ÚKZÚZ, 10259.1","norm_bases":["JPP ÚKZÚZ, 60071.1","JPP ÚKZÚZ, 10251.1","JPP ÚKZÚZ, 10252.1","JPP ÚKZÚZ, 10253.1","JPP ÚKZÚZ, 10700.1","JPP ÚKZÚZ, 10254.1","JPP ÚKZÚZ, 10255.1","JPP ÚKZÚZ, 10257.1","JPP ÚKZÚZ, 10258.1","JPP ÚKZÚZ, 10259.1"],"lab_section":"ÚKZÚZ, NRL, Dział Mikrobiologii i Biochemii","lab_section_en":"ÚKZÚZ, NRL, Department of Microbiology and Biochemistry","lab_section_zh":"ÚKZÚZ, NRL，微生物与生物化学科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení mikrobiologie a biochemie","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Oznaczane elementy przesiewowe: dehydrogenaza alkoholowa C, pirofosforylaza UDP-glukozy, inwertaza skrobiowa, fosfolipaza D, gen kodujący grupę białek I/Y, kruciferyna A, lektyna sojowa, promotor 35S, terminator NOS, promotor FMV, bar, Cry1Ab, Ctp2-cp4epsps, cp4 epsps, nptII, pat, CaMV. Oznaczane transgeny: Bawełna: 281-24-236 x 3006-210-23, GHB119, GHB614, LLCotton25, MON531, MON1445, MON15985, MON88913, T304-40, MON88701, DAS81910-7. Ziemniaki: EH-92-527-1. Kukurydza: Bt11, Bt176, CBH351, DAS1507, DAS40278, DAS59122, GA21, GAT 98140, MIR604, MIR162, MON810, MON863, MON87460, MON88017, MON89034, NK603, T25, 3272, MON 87427, 5307, VCO-01981-5, DP4114-3, MON87403, MON87411, MZIR098, MON87429, MZHG0JG. Ryż: Bt63, LL601, LL62. Rzepak: GT73, MS1xRF1, MS1xRF2, MS8xRf3, T45, TOPAS19/2 (HCN92), DP073496, MS11. Soja: A2704-12, A5547-127, BPS-CV127-9, DP305423-1, DP356043, FG72, MON40-3-2, MON87701, MON87705, MON87708, MON89788, DAS 68416-4, MON 87769, DAS 81419-2, DAS 44406-6, MON87751, SYHT0H2, GMB151.","note_en":"Determined screening elements: alcohol dehydrogenase C, UDP-glucose pyrophosphorylase, starch invertase, phospholipase D, gene coding I/Y group of proteins, cruciferin A, soy lectin, promotor 35S, terminator NOS, promotor FMV, bar, Cry1Ab, Ctp2-cp4epsps, cp4 epsps, nptII, pat, CaMV. Determined transgenes: Cotton: 281-24-236 x 3006-210-23, GHB119, GHB614, LLCotton25, MON531, MON1445, MON15985, MON88913, T304-40, MON88701, DAS81910-7. Potato: EH-92-527-1. Corn: Bt11, Bt176, CBH351, DAS1507, DAS40278, DAS59122, GA21, GAT 98140, MIR604, MIR162, MON810, MON863, MON87460, MON88017, MON89034, NK603, T25, 3272, MON 87427, 5307, VCO-01981-5, DP4114-3, MON87403, MON87411, MZIR098, MON87429, MZHG0JG. Rice: Bt63, LL601, LL62. Rape: GT73, MS1xRF1, MS1xRF2, MS8xRf3, T45, TOPAS19/2 (HCN92), DP073496, MS11. Soya: A2704-12, A5547-127, BPS-CV127-9, DP305423-1, DP356043, FG72, MON40-3-2, MON87701, MON87705, MON87708, MON89788, DAS 68416-4, MON 87769, DAS 81419-2, DAS 44406-6, MON87751, SYHT0H2, GMB151.","note_zh":"测定筛查元件：乙醇脱氢酶C、UDP-葡萄糖焦磷酸化酶、淀粉转化酶、磷脂酶D、编码I/Y组蛋白的基因、十字花科蛋白A、大豆凝集素、35S启动子、NOS终止子、FMV启动子、bar、Cry1Ab、Ctp2-cp4epsps、cp4 epsps、nptII、pat、CaMV。测定转基因：棉花：281-24-236 x 3006-210-23, GHB119, GHB614, LLCotton25, MON531, MON1445, MON15985, MON88913, T304-40, MON88701, DAS81910-7.马铃薯：EH-92-527-1.玉米：Bt11, Bt176, CBH351, DAS1507, DAS40278, DAS59122, GA21, GAT 98140, MIR604, MIR162, MON810, MON863, MON87460, MON88017, MON89034, NK603, T25, 3272, MON 87427, 5307, VCO-01981-5, DP4114-3, MON87403, MON87411, MZIR098, MON87429, MZHG0JG.水稻：Bt63, LL601, LL62.油菜：GT73, MS1xRF1, MS1xRF2, MS8xRf3, T45, TOPAS19/2 (HCN92), DP073496, MS11.大豆：A2704-12, A5547-127, BPS-CV127-9, DP305423-1, DP356043, FG72, MON40-3-2, MON87701, MON87705, MON87708, MON89788, DAS 68416-4, MON 87769, DAS 81419-2, DAS 44406-6, MON87751, SYHT0H2, GMB151.","note_cs":"Stanovované screeningové elementy: alkohol dehydrogenáza C, UDP-glukosopyrofosforyláza, škrobová invertáza, fosfolipáza D, gen kódující skupinu proteinů I/Y, cruciferin A, sójový lektin, promotor 35S, terminátor NOS, promotor FMV, bar, Cry1Ab, Ctp2-cp4epsps, cp4 epsps, nptII, pat, CaMV. Stanovované transgeny: Bavlna: 281-24-236 x 3006-210-23, GHB119, GHB614, LLCotton25, MON531, MON1445, MON15985, MON88913, T304-40, MON88701, DAS81910-7. Brambory: EH-92-527-1. Kukuřice: Bt11, Bt176, CBH351, DAS1507, DAS40278, DAS59122, GA21, GAT 98140, MIR604, MIR162, MON810, MON863, MON87460, MON88017, MON89034, NK603, T25, 3272, MON 87427, 5307, VCO-01981-5, DP4114-3, MON87403, MON87411, MZIR098, MON87429, MZHG0JG. Rýže: Bt63, LL601, LL62. Řepka: GT73, MS1xRF1, MS1xRF2, MS8xRf3, T45, TOPAS19/2 (HCN92), DP073496, MS11. Sója: A2704-12, A5547-127, BPS-CV127-9, DP305423-1, DP356043, FG72, MON40-3-2, MON87701, MON87705, MON87708, MON89788, DAS 68416-4, MON 87769, DAS 81419-2, DAS 44406-6, MON87751, SYHT0H2, GMB151.","search_text":"Pasze i surowce do ich produkcji Wykrywanie obecności GMO metodą PCR Krmiva a suroviny pro jejich výrobu Stanovení přítomnosti GMO metodou PCR JPP ÚKZÚZ, 60071.1; JPP ÚKZÚZ, 10251.1; JPP ÚKZÚZ, 10252.1; JPP ÚKZÚZ, 10253.1; JPP ÚKZÚZ, 10700.1; JPP ÚKZÚZ, 10254.1; JPP ÚKZÚZ, 10255.1; JPP ÚKZÚZ, 10257.1; JPP ÚKZÚZ, 10258.1; JPP ÚKZÚZ, 10259.1 Pasze i surowce do ich produkcji Wykrywanie obecnosci GMO metoda PCR Krmiva a suroviny pro jejich vyrobu Stanoveni pritomnosti GMO metodou PCR JPP UKZUZ, 60071.1; JPP UKZUZ, 10251.1; JPP UKZUZ, 10252.1; JPP UKZUZ, 10253.1; JPP UKZUZ, 10700.1; JPP UKZUZ, 10254.1; JPP UKZUZ, 10255.1; JPP UKZUZ, 10257.1; JPP UKZUZ, 10258.1; JPP UKZUZ, 10259.1","search_en":"Animal feeding stuffs and raw materials for their production Detection of GMO by PCR method JPP ÚKZÚZ, 60071.1; JPP ÚKZÚZ, 10251.1; JPP ÚKZÚZ, 10252.1; JPP ÚKZÚZ, 10253.1; JPP ÚKZÚZ, 10700.1; JPP ÚKZÚZ, 10254.1; JPP ÚKZÚZ, 10255.1; JPP ÚKZÚZ, 10257.1; JPP ÚKZÚZ, 10258.1; JPP ÚKZÚZ, 10259.1","search_zh":"饲料及其生产原料 PCR法检测转基因生物 JPP ÚKZÚZ, 60071.1; JPP ÚKZÚZ, 10251.1; JPP ÚKZÚZ, 10252.1; JPP ÚKZÚZ, 10253.1; JPP ÚKZÚZ, 10700.1; JPP ÚKZÚZ, 10254.1; JPP ÚKZÚZ, 10255.1; JPP ÚKZÚZ, 10257.1; JPP ÚKZÚZ, 10258.1; JPP ÚKZÚZ, 10259.1","categories":["food","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":193,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"606603bcd91d9a3162f737e6","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"2","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osiva","methodology":"Wykrywanie obecności GMO metodą PCR","methodology_en":"Detection of GMO by PCR method","methodology_zh":"PCR法检测转基因生物","methodology_cs":"Stanovení přítomnosti GMO metodou PCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie obecności GMO metodą PCR","reference":"JPP ÚKZÚZ, 60072.1; JPP ÚKZÚZ, 10251.1; JPP ÚKZÚZ, 10252.1; JPP ÚKZÚZ, 10253.1; JPP ÚKZÚZ, 10700.1; JPP ÚKZÚZ, 10254.1; JPP ÚKZÚZ, 10255.1; JPP ÚKZÚZ, 10257.1; JPP ÚKZÚZ, 10258.1; JPP ÚKZÚZ, 10259.1","norm_bases":["JPP ÚKZÚZ, 60072.1","JPP ÚKZÚZ, 10251.1","JPP ÚKZÚZ, 10252.1","JPP ÚKZÚZ, 10253.1","JPP ÚKZÚZ, 10700.1","JPP ÚKZÚZ, 10254.1","JPP ÚKZÚZ, 10255.1","JPP ÚKZÚZ, 10257.1","JPP ÚKZÚZ, 10258.1","JPP ÚKZÚZ, 10259.1"],"lab_section":"ÚKZÚZ, NRL, Dział Mikrobiologii i Biochemii","lab_section_en":"ÚKZÚZ, NRL, Department of Microbiology and Biochemistry","lab_section_zh":"ÚKZÚZ, NRL，微生物与生物化学科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení mikrobiologie a biochemie","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Oznaczane elementy przesiewowe: dehydrogenaza alkoholowa C, pirofosforylaza UDP-glukozy, inwertaza skrobiowa, fosfolipaza D, gen kodujący grupę białek I/Y, kruciferyna A, lektyna sojowa, promotor 35S, terminator NOS, promotor FMV, bar, Cry1Ab, Ctp2-cp4epsps, cp4 epsps, nptII, pat, CaMV. Oznaczane transgeny: Kukurydza: Bt11, Bt176, CBH351, DAS1507, DAS40278, DAS59122, GA21, GAT 98140, MIR604, MIR162, MON810, MON863, MON87460, MON88017, MON89034, NK603, T25, 3272, MON 87427, 5307, VCO-01981-5, DP4114-3, MON87403, MON87411, MZIR098, MON87429, MZHG0JG. Rzepak: GT73, MS1xRF1, MS1xRF2, MS8xRf3, T45, TOPAS19/2 (HCN92), DP073496, MS11. Soja: A2704-12, A5547-127, BPS-CV127-9, DP305423-1, DP356043, FG72, MON40-3-2, MON87701, MON87705, MON87708, MON89788, DAS 68416-4, MON 87769, DAS 81419-2, DAS 44406-6, MON87751, SYHT0H2, GMB151.","note_en":"Determined screening elements: alcohol dehydrogenase C, UDP-glucose pyrophosphorylase, starch invertase, phospholipase D, gene coding I/Y group of proteins, cruciferin A, soy lectin, promotor 35S, terminator NOS, promotor FMV, bar, Cry1Ab, Ctp2-cp4epsps, cp4 epsps, nptII, pat, CaMV. Determined transgenes: Corn: Bt11, Bt176, CBH351, DAS1507, DAS40278, DAS59122, GA21, GAT 98140, MIR604, MIR162, MON810, MON863, MON87460, MON88017, MON89034, NK603, T25, 3272, MON 87427, 5307, VCO-01981-5, DP4114-3, MON87403, MON87411, MZIR098, MON87429, MZHG0JG. Rape: GT73, MS1xRF1, MS1xRF2, MS8xRf3, T45, TOPAS19/2 (HCN92), DP073496, MS11. Soya: A2704-12, A5547-127, BPS-CV127-9, DP305423-1, DP356043, FG72, MON40-3-2, MON87701, MON87705, MON87708, MON89788, DAS 68416-4, MON 87769, DAS 81419-2, DAS 44406-6, MON87751, SYHT0H2, GMB151.","note_zh":"测定筛查元件：乙醇脱氢酶C、UDP-葡萄糖焦磷酸化酶、淀粉转化酶、磷脂酶D、编码I/Y组蛋白的基因、十字花科蛋白A、大豆凝集素、35S启动子、NOS终止子、FMV启动子、bar、Cry1Ab、Ctp2-cp4epsps、cp4 epsps、nptII、pat、CaMV。测定转基因：玉米：Bt11, Bt176, CBH351, DAS1507, DAS40278, DAS59122, GA21, GAT 98140, MIR604, MIR162, MON810, MON863, MON87460, MON88017, MON89034, NK603, T25, 3272, MON 87427, 5307, VCO-01981-5, DP4114-3, MON87403, MON87411, MZIR098, MON87429, MZHG0JG.油菜：GT73, MS1xRF1, MS1xRF2, MS8xRf3, T45, TOPAS19/2 (HCN92), DP073496, MS11.大豆：A2704-12, A5547-127, BPS-CV127-9, DP305423-1, DP356043, FG72, MON40-3-2, MON87701, MON87705, MON87708, MON89788, DAS 68416-4, MON 87769, DAS 81419-2, DAS 44406-6, MON87751, SYHT0H2, GMB151.","note_cs":"Stanovované screeningové elementy: alkohol dehydrogenáza C, UDP-glukosopyrofosforyláza, škrobová invertáza, fosfolipáza D, gen kódující skupinu proteinů I/Y, cruciferin A, sójový lektin, promotor 35S, terminátor NOS, promotor FMV, bar, Cry1Ab, Ctp2-cp4epsps, cp4 epsps, nptII, pat, CaMV. Stanovované transgeny: Kukuřice: Bt11, Bt176, CBH351, DAS1507, DAS40278, DAS59122, GA21, GAT 98140, MIR604, MIR162, MON810, MON863, MON87460, MON88017, MON89034, NK603, T25, 3272, MON 87427, 5307, VCO-01981-5, DP4114-3, MON87403, MON87411, MZIR098, MON87429, MZHG0JG. Řepka: GT73, MS1xRF1, MS1xRF2, MS8xRf3, T45, TOPAS19/2 (HCN92), DP073496, MS11. Sója: A2704-12, A5547-127, BPS-CV127-9, DP305423-1, DP356043, FG72, MON40-3-2, MON87701, MON87705, MON87708, MON89788, DAS 68416-4, MON 87769, DAS 81419-2, DAS 44406-6, MON87751, SYHT0H2, GMB151.","search_text":"Materiał siewny Wykrywanie obecności GMO metodą PCR Osiva Stanovení přítomnosti GMO metodou PCR JPP ÚKZÚZ, 60072.1; JPP ÚKZÚZ, 10251.1; JPP ÚKZÚZ, 10252.1; JPP ÚKZÚZ, 10253.1; JPP ÚKZÚZ, 10700.1; JPP ÚKZÚZ, 10254.1; JPP ÚKZÚZ, 10255.1; JPP ÚKZÚZ, 10257.1; JPP ÚKZÚZ, 10258.1; JPP ÚKZÚZ, 10259.1 Material siewny Wykrywanie obecnosci GMO metoda PCR Osiva Stanoveni pritomnosti GMO metodou PCR JPP UKZUZ, 60072.1; JPP UKZUZ, 10251.1; JPP UKZUZ, 10252.1; JPP UKZUZ, 10253.1; JPP UKZUZ, 10700.1; JPP UKZUZ, 10254.1; JPP UKZUZ, 10255.1; JPP UKZUZ, 10257.1; JPP UKZUZ, 10258.1; JPP UKZUZ, 10259.1","search_en":"Seed Detection of GMO by PCR method JPP ÚKZÚZ, 60072.1; JPP ÚKZÚZ, 10251.1; JPP ÚKZÚZ, 10252.1; JPP ÚKZÚZ, 10253.1; JPP ÚKZÚZ, 10700.1; JPP ÚKZÚZ, 10254.1; JPP ÚKZÚZ, 10255.1; JPP ÚKZÚZ, 10257.1; JPP ÚKZÚZ, 10258.1; JPP ÚKZÚZ, 10259.1","search_zh":"种子 PCR法检测转基因生物 JPP ÚKZÚZ, 60072.1; JPP ÚKZÚZ, 10251.1; JPP ÚKZÚZ, 10252.1; JPP ÚKZÚZ, 10253.1; JPP ÚKZÚZ, 10700.1; JPP ÚKZÚZ, 10254.1; JPP ÚKZÚZ, 10255.1; JPP ÚKZÚZ, 10257.1; JPP ÚKZÚZ, 10258.1; JPP ÚKZÚZ, 10259.1","categories":["food","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":194,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"261cf5d039f19c162444f7d3","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"3","test_object":"Wegetatywne części roślin","test_object_en":"Vegetative parts of plants","test_object_zh":"植物营养器官","test_object_cs":"Vegetativní části rostlin","methodology":"Wykrywanie obecności GMO metodą PCR","methodology_en":"Detection of GMO by PCR method","methodology_zh":"PCR法检测转基因生物","methodology_cs":"Stanovení přítomnosti GMO metodou PCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie obecności GMO metodą PCR","reference":"JPP ÚKZÚZ, 60073.1; JPP ÚKZÚZ, 60074.1; JPP ÚKZÚZ, 10251.1; JPP ÚKZÚZ, 10252.1; JPP ÚKZÚZ, 10253.1; JPP ÚKZÚZ, 10700.1; JPP ÚKZÚZ, 10254.1; JPP ÚKZÚZ, 10255.1; JPP ÚKZÚZ, 10257.1; JPP ÚKZÚZ, 10258.1; JPP ÚKZÚZ, 10259.1","norm_bases":["JPP ÚKZÚZ, 60073.1","JPP ÚKZÚZ, 60074.1","JPP ÚKZÚZ, 10251.1","JPP ÚKZÚZ, 10252.1","JPP ÚKZÚZ, 10253.1","JPP ÚKZÚZ, 10700.1","JPP ÚKZÚZ, 10254.1","JPP ÚKZÚZ, 10255.1","JPP ÚKZÚZ, 10257.1","JPP ÚKZÚZ, 10258.1","JPP ÚKZÚZ, 10259.1"],"lab_section":"ÚKZÚZ, NRL, Dział Mikrobiologii i Biochemii","lab_section_en":"ÚKZÚZ, NRL, Department of Microbiology and Biochemistry","lab_section_zh":"ÚKZÚZ, NRL，微生物与生物化学科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení mikrobiologie a biochemie","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Oznaczane elementy przesiewowe: dehydrogenaza alkoholowa C, pirofosforylaza UDP-glukozy, inwertaza skrobiowa, fosfolipaza D, gen kodujący grupę białek I/Y, kruciferyna A, lektyna sojowa, promotor 35S, terminator NOS, promotor FMV, bar, Cry1Ab, Ctp2-cp4epsps, cp4 epsps, nptII, pat, CaMV. Oznaczane transgeny: Ziemniaki: EH-92-527-1. Kukurydza: Bt11, Bt176, CBH351, DAS1507, DAS40278, DAS59122, GA21, GAT 98140, MIR604, MIR162, MON810, MON863, MON87460, MON88017, MON89034, NK603, T25, 3272, MON 87427, 5307, VCO-01981-5, DP4114-3, MON87403, MON87411, MZIR098, MON87429, MZHG0JG. Rzepak: GT73, MS1xRF1, MS1xRF2, MS8xRf3, T45, TOPAS19/2 (HCN92), DP073496, MS11. Soja: A2704-12, A5547-127, BPS-CV127-9, DP305423-1, DP356043, FG72, MON40-3-2, MON87701, MON87705, MON87708, MON89788, DAS 68416-4, MON 87769, DAS 81419-2, DAS 44406-6, MON87751, SYHT0H2, GMB151.","note_en":"Determined screening elements: alcohol dehydrogenase C, UDP-glucose pyrophosphorylase, starch invertase, phospholipase D, gene coding I/Y group of proteins, cruciferin A, soy lectin, promotor 35S, terminator NOS, promotor FMV, bar, Cry1Ab, Ctp2-cp4epsps, cp4 epsps, nptII, pat, CaMV. Determined transgenes: Potato: EH-92-527-1. Corn: Bt11, Bt176, CBH351, DAS1507, DAS40278, DAS59122, GA21, GAT 98140, MIR604, MIR162, MON810, MON863, MON87460, MON88017, MON89034, NK603, T25, 3272, MON 87427, 5307, VCO-01981-5, DP4114-3, MON87403, MON87411, MZIR098, MON87429, MZHG0JG. Rape: GT73, MS1xRF1, MS1xRF2, MS8xRf3, T45, TOPAS19/2 (HCN92), DP073496, MS11. Soya: A2704-12, A5547-127, BPS-CV127-9, DP305423-1, DP356043, FG72, MON40-3-2, MON87701, MON87705, MON87708, MON89788, DAS 68416-4, MON 87769, DAS 81419-2, DAS 44406-6, MON87751, SYHT0H2, GMB151.","note_zh":"测定筛查元件：乙醇脱氢酶C、UDP-葡萄糖焦磷酸化酶、淀粉转化酶、磷脂酶D、编码I/Y组蛋白的基因、十字花科蛋白A、大豆凝集素、35S启动子、NOS终止子、FMV启动子、bar、Cry1Ab、Ctp2-cp4epsps、cp4 epsps、nptII、pat、CaMV。测定转基因：马铃薯：EH-92-527-1.玉米：Bt11, Bt176, CBH351, DAS1507, DAS40278, DAS59122, GA21, GAT 98140, MIR604, MIR162, MON810, MON863, MON87460, MON88017, MON89034, NK603, T25, 3272, MON 87427, 5307, VCO-01981-5, DP4114-3, MON87403, MON87411, MZIR098, MON87429, MZHG0JG.油菜：GT73, MS1xRF1, MS1xRF2, MS8xRf3, T45, TOPAS19/2 (HCN92), DP073496, MS11.大豆：A2704-12, A5547-127, BPS-CV127-9, DP305423-1, DP356043, FG72, MON40-3-2, MON87701, MON87705, MON87708, MON89788, DAS 68416-4, MON 87769, DAS 81419-2, DAS 44406-6, MON87751, SYHT0H2, GMB151.","note_cs":"Stanovované screeningové elementy: alkohol dehydrogenáza C, UDP-glukosopyrofosforyláza, škrobová invertáza, fosfolipáza D, gen kódující skupinu proteinů I/Y, cruciferin A, sójový lektin, promotor 35S, terminátor NOS, promotor FMV, bar, Cry1Ab, Ctp2-cp4epsps, cp4 epsps, nptII, pat, CaMV. Stanovované transgeny: Brambory: EH-92-527-1. Kukuřice: Bt11, Bt176, CBH351, DAS1507, DAS40278, DAS59122, GA21, GAT 98140, MIR604, MIR162, MON810, MON863, MON87460, MON88017, MON89034, NK603, T25, 3272, MON 87427, 5307, VCO-01981-5, DP4114-3, MON87403, MON87411, MZIR098, MON87429, MZHG0JG. Řepka: GT73, MS1xRF1, MS1xRF2, MS8xRf3, T45, TOPAS19/2 (HCN92), DP073496, MS11. Sója: A2704-12, A5547-127, BPS-CV127-9, DP305423-1, DP356043, FG72, MON40-3-2, MON87701, MON87705, MON87708, MON89788, DAS 68416-4, MON 87769, DAS 81419-2, DAS 44406-6, MON87751, SYHT0H2, GMB151.","search_text":"Wegetatywne części roślin Wykrywanie obecności GMO metodą PCR Vegetativní části rostlin Stanovení přítomnosti GMO metodou PCR JPP ÚKZÚZ, 60073.1; JPP ÚKZÚZ, 60074.1; JPP ÚKZÚZ, 10251.1; JPP ÚKZÚZ, 10252.1; JPP ÚKZÚZ, 10253.1; JPP ÚKZÚZ, 10700.1; JPP ÚKZÚZ, 10254.1; JPP ÚKZÚZ, 10255.1; JPP ÚKZÚZ, 10257.1; JPP ÚKZÚZ, 10258.1; JPP ÚKZÚZ, 10259.1 Wegetatywne czesci roslin Wykrywanie obecnosci GMO metoda PCR Vegetativni casti rostlin Stanoveni pritomnosti GMO metodou PCR JPP UKZUZ, 60073.1; JPP UKZUZ, 60074.1; JPP UKZUZ, 10251.1; JPP UKZUZ, 10252.1; JPP UKZUZ, 10253.1; JPP UKZUZ, 10700.1; JPP UKZUZ, 10254.1; JPP UKZUZ, 10255.1; JPP UKZUZ, 10257.1; JPP UKZUZ, 10258.1; JPP UKZUZ, 10259.1","search_en":"Vegetative parts of plants Detection of GMO by PCR method JPP ÚKZÚZ, 60073.1; JPP ÚKZÚZ, 60074.1; JPP ÚKZÚZ, 10251.1; JPP ÚKZÚZ, 10252.1; JPP ÚKZÚZ, 10253.1; JPP ÚKZÚZ, 10700.1; JPP ÚKZÚZ, 10254.1; JPP ÚKZÚZ, 10255.1; JPP ÚKZÚZ, 10257.1; JPP ÚKZÚZ, 10258.1; JPP ÚKZÚZ, 10259.1","search_zh":"植物营养器官 PCR法检测转基因生物 JPP ÚKZÚZ, 60073.1; JPP ÚKZÚZ, 60074.1; JPP ÚKZÚZ, 10251.1; JPP ÚKZÚZ, 10252.1; JPP ÚKZÚZ, 10253.1; JPP ÚKZÚZ, 10700.1; JPP ÚKZÚZ, 10254.1; JPP ÚKZÚZ, 10255.1; JPP ÚKZÚZ, 10257.1; JPP ÚKZÚZ, 10258.1; JPP ÚKZÚZ, 10259.1","categories":["food","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":195,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f2fed0c0e86679a8ddf7300e","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"4","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Jakościowe oznaczanie elementów przesiewowych i modyfikacji genetycznych metodą qPCR","methodology_en":"Qualitative determination of screening elements and genetic modifications by qPCR method","methodology_zh":"qPCR法定性测定筛查元件和遗传修饰","methodology_cs":"Kvalitativní stanovení screeningových elementů a genetických modifikací metodou qPCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Jakościowe oznaczanie elementów przesiewowych i modyfikacji genetycznych metodą qPCR","reference":"JPP ÚKZÚZ, 10262.1; JPP ÚKZÚZ, 10262.2; JPP ÚKZÚZ, 10263.1","norm_bases":["JPP ÚKZÚZ, 10262.1","JPP ÚKZÚZ, 10262.2","JPP ÚKZÚZ, 10263.1"],"lab_section":"ÚKZÚZ, NRL, Dział Mikrobiologii i Biochemii","lab_section_en":"ÚKZÚZ, NRL, Department of Microbiology and Biochemistry","lab_section_zh":"ÚKZÚZ, NRL，微生物与生物化学科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení mikrobiologie a biochemie","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Oznaczane elementy przesiewowe: bar. Oznaczane transgeny: Kukurydza: GAT98140, MON810. Soja: MON40-3-2, MON89788, MON87701.","note_en":"Determined screening elements: bar. Determined transgenes: Corn: GAT98140, MON810. Soya: MON40-3-2, MON89788, MON87701.","note_zh":"测定筛查元件：bar。测定转基因：玉米：GAT98140, MON810.大豆：MON40-3-2, MON89788, MON87701.","note_cs":"Stanovované screeningové elementy: bar. Stanovované transgeny: Kukuřice: GAT98140, MON810. Sója: MON40-3-2, MON89788, MON87701.","search_text":"Pasze i surowce do ich produkcji Jakościowe oznaczanie elementów przesiewowych i modyfikacji genetycznych metodą qPCR Krmiva a suroviny pro jejich výrobu Kvalitativní stanovení screeningových elementů a genetických modifikací metodou qPCR JPP ÚKZÚZ, 10262.1; JPP ÚKZÚZ, 10262.2; JPP ÚKZÚZ, 10263.1 Pasze i surowce do ich produkcji Jakosciowe oznaczanie elementow przesiewowych i modyfikacji genetycznych metoda qPCR Krmiva a suroviny pro jejich vyrobu Kvalitativni stanoveni screeningovych elementu a genetickych modifikaci metodou qPCR JPP UKZUZ, 10262.1; JPP UKZUZ, 10262.2; JPP UKZUZ, 10263.1","search_en":"Animal feeding stuffs and raw materials for their production Qualitative determination of screening elements and genetic modifications by qPCR method JPP ÚKZÚZ, 10262.1; JPP ÚKZÚZ, 10262.2; JPP ÚKZÚZ, 10263.1","search_zh":"饲料及其生产原料 qPCR法定性测定筛查元件和遗传修饰 JPP ÚKZÚZ, 10262.1; JPP ÚKZÚZ, 10262.2; JPP ÚKZÚZ, 10263.1","categories":["food","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":196,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"22a046011ac604de95eeee0b","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"5","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osiva","methodology":"Jakościowe oznaczanie elementów przesiewowych i modyfikacji genetycznych metodą qPCR","methodology_en":"Qualitative determination of screening elements and genetic modifications by qPCR method","methodology_zh":"qPCR法定性测定筛查元件和遗传修饰","methodology_cs":"Kvalitativní stanovení screeningových elementů a genetických modifikací metodou qPCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Jakościowe oznaczanie elementów przesiewowych i modyfikacji genetycznych metodą qPCR","reference":"JPP ÚKZÚZ, 10262.1; JPP ÚKZÚZ, 10262.2; JPP ÚKZÚZ, 10263.1","norm_bases":["JPP ÚKZÚZ, 10262.1","JPP ÚKZÚZ, 10262.2","JPP ÚKZÚZ, 10263.1"],"lab_section":"ÚKZÚZ, NRL, Dział Mikrobiologii i Biochemii","lab_section_en":"ÚKZÚZ, NRL, Department of Microbiology and Biochemistry","lab_section_zh":"ÚKZÚZ, NRL，微生物与生物化学科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení mikrobiologie a biochemie","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Oznaczane elementy przesiewowe: bar. Oznaczane transgeny: Kukurydza: GAT98140, MON810. Soja: MON40-3-2, MON89788, MON87701.","note_en":"Determined screening elements: bar. Determined transgenes: Corn: GAT98140, MON810. Soya: MON40-3-2, MON89788, MON87701.","note_zh":"测定筛查元件：bar。测定转基因：玉米：GAT98140, MON810.大豆：MON40-3-2, MON89788, MON87701.","note_cs":"Stanovované screeningové elementy: bar. Stanovované transgeny: Kukuřice: GAT98140, MON810. Sója: MON40-3-2, MON89788, MON87701.","search_text":"Materiał siewny Jakościowe oznaczanie elementów przesiewowych i modyfikacji genetycznych metodą qPCR Osiva Kvalitativní stanovení screeningových elementů a genetických modifikací metodou qPCR JPP ÚKZÚZ, 10262.1; JPP ÚKZÚZ, 10262.2; JPP ÚKZÚZ, 10263.1 Material siewny Jakosciowe oznaczanie elementow przesiewowych i modyfikacji genetycznych metoda qPCR Osiva Kvalitativni stanoveni screeningovych elementu a genetickych modifikaci metodou qPCR JPP UKZUZ, 10262.1; JPP UKZUZ, 10262.2; JPP UKZUZ, 10263.1","search_en":"Seed Qualitative determination of screening elements and genetic modifications by qPCR method JPP ÚKZÚZ, 10262.1; JPP ÚKZÚZ, 10262.2; JPP ÚKZÚZ, 10263.1","search_zh":"种子 qPCR法定性测定筛查元件和遗传修饰 JPP ÚKZÚZ, 10262.1; JPP ÚKZÚZ, 10262.2; JPP ÚKZÚZ, 10263.1","categories":["food","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":197,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b3e400f37f0d8d0039b5a944","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"6","test_object":"Wegetatywne części roślin","test_object_en":"Vegetative parts of plants","test_object_zh":"植物营养器官","test_object_cs":"Vegetativní části rostlin","methodology":"Jakościowe oznaczanie elementów przesiewowych i modyfikacji genetycznych metodą qPCR","methodology_en":"Qualitative determination of screening elements and genetic modifications by qPCR method","methodology_zh":"qPCR法定性测定筛查元件和遗传修饰","methodology_cs":"Kvalitativní stanovení screeningových elementů a genetických modifikací metodou qPCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Jakościowe oznaczanie elementów przesiewowych i modyfikacji genetycznych metodą qPCR","reference":"JPP ÚKZÚZ, 10262.1; JPP ÚKZÚZ, 10262.2; JPP ÚKZÚZ, 10263.1","norm_bases":["JPP ÚKZÚZ, 10262.1","JPP ÚKZÚZ, 10262.2","JPP ÚKZÚZ, 10263.1"],"lab_section":"ÚKZÚZ, NRL, Dział Mikrobiologii i Biochemii","lab_section_en":"ÚKZÚZ, NRL, Department of Microbiology and Biochemistry","lab_section_zh":"ÚKZÚZ, NRL，微生物与生物化学科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení mikrobiologie a biochemie","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Oznaczane elementy przesiewowe: bar. Oznaczane transgeny: Kukurydza: GAT98140, MON810. Soja: MON40-3-2, MON89788, MON87701.","note_en":"Determined screening elements: bar. Determined transgenes: Corn: GAT98140, MON810. Soya: MON40-3-2, MON89788, MON87701.","note_zh":"测定筛查元件：bar。测定转基因：玉米：GAT98140, MON810.大豆：MON40-3-2, MON89788, MON87701.","note_cs":"Stanovované screeningové elementy: bar. Stanovované transgeny: Kukuřice: GAT98140, MON810. Sója: MON40-3-2, MON89788, MON87701.","search_text":"Wegetatywne części roślin Jakościowe oznaczanie elementów przesiewowych i modyfikacji genetycznych metodą qPCR Vegetativní části rostlin Kvalitativní stanovení screeningových elementů a genetických modifikací metodou qPCR JPP ÚKZÚZ, 10262.1; JPP ÚKZÚZ, 10262.2; JPP ÚKZÚZ, 10263.1 Wegetatywne czesci roslin Jakosciowe oznaczanie elementow przesiewowych i modyfikacji genetycznych metoda qPCR Vegetativni casti rostlin Kvalitativni stanoveni screeningovych elementu a genetickych modifikaci metodou qPCR JPP UKZUZ, 10262.1; JPP UKZUZ, 10262.2; JPP UKZUZ, 10263.1","search_en":"Vegetative parts of plants Qualitative determination of screening elements and genetic modifications by qPCR method JPP ÚKZÚZ, 10262.1; JPP ÚKZÚZ, 10262.2; JPP ÚKZÚZ, 10263.1","search_zh":"植物营养器官 qPCR法定性测定筛查元件和遗传修饰 JPP ÚKZÚZ, 10262.1; JPP ÚKZÚZ, 10262.2; JPP ÚKZÚZ, 10263.1","categories":["food","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":198,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b2ca11cfd99d8843d135bb2a","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"7","test_object":"Pasze i surowce do ich produkcji","test_object_en":"Animal feeding stuffs and raw materials for their production","test_object_zh":"饲料及其生产原料","test_object_cs":"Krmiva a suroviny pro jejich výrobu","methodology":"Ilościowe oznaczanie modyfikacji genetycznych metodą qPCR","methodology_en":"Quantitative determination of genetic modifications by qPCR method","methodology_zh":"qPCR法定量测定遗传修饰","methodology_cs":"Kvantitativní stanovení genetických modifikací metodou qPCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ilościowe oznaczanie modyfikacji genetycznych metodą qPCR","reference":"JPP ÚKZÚZ, 10264.1; JPP ÚKZÚZ, 10264.2; JPP ÚKZÚZ, 10265.1","norm_bases":["JPP ÚKZÚZ, 10264.1","JPP ÚKZÚZ, 10264.2","JPP ÚKZÚZ, 10265.1"],"lab_section":"ÚKZÚZ, NRL, Dział Mikrobiologii i Biochemii","lab_section_en":"ÚKZÚZ, NRL, Department of Microbiology and Biochemistry","lab_section_zh":"ÚKZÚZ, NRL，微生物与生物化学科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení mikrobiologie a biochemie","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Oznaczane transgeny: Kukurydza: MON810. Soja: MON40-3-2, MON89788, MON87701.","note_en":"Determined transgenes: Corn: MON810. Soya: MON40-3-2, MON89788, MON87701.","note_zh":"测定转基因：玉米：MON810.大豆：MON40-3-2, MON89788, MON87701.","note_cs":"Stanovované transgeny: Kukuřice: MON810. Sója: MON40-3-2, MON89788, MON87701.","search_text":"Pasze i surowce do ich produkcji Ilościowe oznaczanie modyfikacji genetycznych metodą qPCR Krmiva a suroviny pro jejich výrobu Kvantitativní stanovení genetických modifikací metodou qPCR JPP ÚKZÚZ, 10264.1; JPP ÚKZÚZ, 10264.2; JPP ÚKZÚZ, 10265.1 Pasze i surowce do ich produkcji Ilosciowe oznaczanie modyfikacji genetycznych metoda qPCR Krmiva a suroviny pro jejich vyrobu Kvantitativni stanoveni genetickych modifikaci metodou qPCR JPP UKZUZ, 10264.1; JPP UKZUZ, 10264.2; JPP UKZUZ, 10265.1","search_en":"Animal feeding stuffs and raw materials for their production Quantitative determination of genetic modifications by qPCR method JPP ÚKZÚZ, 10264.1; JPP ÚKZÚZ, 10264.2; JPP ÚKZÚZ, 10265.1","search_zh":"饲料及其生产原料 qPCR法定量测定遗传修饰 JPP ÚKZÚZ, 10264.1; JPP ÚKZÚZ, 10264.2; JPP ÚKZÚZ, 10265.1","categories":["food","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":199,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5f4553669424c4add0a86bbc","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"8","test_object":"Materiał siewny","test_object_en":"Seed","test_object_zh":"种子","test_object_cs":"Osiva","methodology":"Ilościowe oznaczanie modyfikacji genetycznych metodą qPCR","methodology_en":"Quantitative determination of genetic modifications by qPCR method","methodology_zh":"qPCR法定量测定遗传修饰","methodology_cs":"Kvantitativní stanovení genetických modifikací metodou qPCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ilościowe oznaczanie modyfikacji genetycznych metodą qPCR","reference":"JPP ÚKZÚZ, 10264.1; JPP ÚKZÚZ, 10264.2; JPP ÚKZÚZ, 10265.1","norm_bases":["JPP ÚKZÚZ, 10264.1","JPP ÚKZÚZ, 10264.2","JPP ÚKZÚZ, 10265.1"],"lab_section":"ÚKZÚZ, NRL, Dział Mikrobiologii i Biochemii","lab_section_en":"ÚKZÚZ, NRL, Department of Microbiology and Biochemistry","lab_section_zh":"ÚKZÚZ, NRL，微生物与生物化学科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení mikrobiologie a biochemie","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Oznaczane transgeny: Kukurydza: MON810. Soja: MON40-3-2, MON89788, MON87701.","note_en":"Determined transgenes: Corn: MON810. Soya: MON40-3-2, MON89788, MON87701.","note_zh":"测定转基因：玉米：MON810.大豆：MON40-3-2, MON89788, MON87701.","note_cs":"Stanovované transgeny: Kukuřice: MON810. Sója: MON40-3-2, MON89788, MON87701.","search_text":"Materiał siewny Ilościowe oznaczanie modyfikacji genetycznych metodą qPCR Osiva Kvantitativní stanovení genetických modifikací metodou qPCR JPP ÚKZÚZ, 10264.1; JPP ÚKZÚZ, 10264.2; JPP ÚKZÚZ, 10265.1 Material siewny Ilosciowe oznaczanie modyfikacji genetycznych metoda qPCR Osiva Kvantitativni stanoveni genetickych modifikaci metodou qPCR JPP UKZUZ, 10264.1; JPP UKZUZ, 10264.2; JPP UKZUZ, 10265.1","search_en":"Seed Quantitative determination of genetic modifications by qPCR method JPP ÚKZÚZ, 10264.1; JPP ÚKZÚZ, 10264.2; JPP ÚKZÚZ, 10265.1","search_zh":"种子 qPCR法定量测定遗传修饰 JPP ÚKZÚZ, 10264.1; JPP ÚKZÚZ, 10264.2; JPP ÚKZÚZ, 10265.1","categories":["food","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":200,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a9acaca1f3972899fa953868","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"9","test_object":"Wegetatywne części roślin","test_object_en":"Vegetative parts of plants","test_object_zh":"植物营养器官","test_object_cs":"Vegetativní části rostlin","methodology":"Ilościowe oznaczanie modyfikacji genetycznych metodą qPCR","methodology_en":"Quantitative determination of genetic modifications by qPCR method","methodology_zh":"qPCR法定量测定遗传修饰","methodology_cs":"Kvantitativní stanovení genetických modifikací metodou qPCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ilościowe oznaczanie modyfikacji genetycznych metodą qPCR","reference":"JPP ÚKZÚZ, 10264.1; JPP ÚKZÚZ, 10264.2; JPP ÚKZÚZ, 10265.1","norm_bases":["JPP ÚKZÚZ, 10264.1","JPP ÚKZÚZ, 10264.2","JPP ÚKZÚZ, 10265.1"],"lab_section":"ÚKZÚZ, NRL, Dział Mikrobiologii i Biochemii","lab_section_en":"ÚKZÚZ, NRL, Department of Microbiology and Biochemistry","lab_section_zh":"ÚKZÚZ, NRL，微生物与生物化学科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení mikrobiologie a biochemie","lab_address":"Hroznová 63/2, 603 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B, D","outside_premises":false,"note":"Oznaczane transgeny: Kukurydza: MON810. Soja: MON40-3-2, MON89788, MON87701.","note_en":"Determined transgenes: Corn: MON810. Soya: MON40-3-2, MON89788, MON87701.","note_zh":"测定转基因：玉米：MON810.大豆：MON40-3-2, MON89788, MON87701.","note_cs":"Stanovované transgeny: Kukuřice: MON810. Sója: MON40-3-2, MON89788, MON87701.","search_text":"Wegetatywne części roślin Ilościowe oznaczanie modyfikacji genetycznych metodą qPCR Vegetativní části rostlin Kvantitativní stanovení genetických modifikací metodou qPCR JPP ÚKZÚZ, 10264.1; JPP ÚKZÚZ, 10264.2; JPP ÚKZÚZ, 10265.1 Wegetatywne czesci roslin Ilosciowe oznaczanie modyfikacji genetycznych metoda qPCR Vegetativni casti rostlin Kvantitativni stanoveni genetickych modifikaci metodou qPCR JPP UKZUZ, 10264.1; JPP UKZUZ, 10264.2; JPP UKZUZ, 10265.1","search_en":"Vegetative parts of plants Quantitative determination of genetic modifications by qPCR method JPP ÚKZÚZ, 10264.1; JPP ÚKZÚZ, 10264.2; JPP ÚKZÚZ, 10265.1","search_zh":"植物营养器官 qPCR法定量测定遗传修饰 JPP ÚKZÚZ, 10264.1; JPP ÚKZÚZ, 10264.2; JPP ÚKZÚZ, 10265.1","categories":["food","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":201,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"91c641e6a192f53fd175c9dc","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"1","test_object":"Materiał roślinny, materiał siewny, owady","test_object_en":"Plant material, seed, insects","test_object_zh":"植物材料、种子、昆虫","test_object_cs":"Rostlinný materiál, osivo, hmyz","methodology":"Wykrywanie wirusów roślin metodą ELISA","methodology_en":"Detection of plant viruses by ELISA method","methodology_zh":"ELISA法检测植物病毒","methodology_cs":"Detekce rostlinných virů metodou ELISA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie wirusów roślin metodą ELISA","reference":"SOP-M-01, mimo kap. 7.2 (Návod výrobce kitu)","norm_bases":["SOP-M-01","Návod výrobce kitu"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wykaz badanych organizmów: zestawy ELISA do diagnostyki wirusów roślin producentów: Agdia, Bioreba, Creative Diagnostics, DSMZ, Loewe, Neogen, Sediag, Prime Diagnostics Literatura źródłowa: PM 7/125 ELISA tests for viruses. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"List of organisms tested: ELISA kits for the diagnostics of plant viruses from manufacturers: Agdia, Bioreba, Creative Diagnostics, DSMZ, Loewe, Neogen, Sediag, Prime Diagnostics Source literature: PM 7/125 ELISA tests for viruses. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"检测生物清单：以下生产商的植物病毒诊断ELISA试剂盒：Agdia, Bioreba, Creative Diagnostics, DSMZ, Loewe, Neogen, Sediag, Prime Diagnostics参考文献：PM 7/125 ELISA tests for viruses.相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Seznam testovaných organismů: ELISA kity pro diagnostiku rostlinných virů od výrobců: Agdia, Bioreba, Creative Diagnostics, DSMZ, Loewe, Neogen, Sediag, Prime Diagnostics Zdrojová literatura: PM 7/125 ELISA tests for viruses. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, materiał siewny, owady Wykrywanie wirusów roślin metodą ELISA Rostlinný materiál, osivo, hmyz Detekce rostlinných virů metodou ELISA SOP-M-01, mimo kap. 7.2 (Návod výrobce kitu) Material roslinny, material siewny, owady Wykrywanie wirusow roslin metoda ELISA Rostlinny material, osivo, hmyz Detekce rostlinnych viru metodou ELISA SOP-M-01, mimo kap. 7.2 (Navod vyrobce kitu)","search_en":"Plant material, seed, insects Detection of plant viruses by ELISA method SOP-M-01, mimo kap. 7.2 (Návod výrobce kitu)","search_zh":"植物材料、种子、昆虫 ELISA法检测植物病毒 SOP-M-01, mimo kap. 7.2 (Návod výrobce kitu)","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":202,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0973d20bf0a30297d6d3e2c6","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"2","test_object":"Materiał roślinny, materiał siewny","test_object_en":"Plant material, seed","test_object_zh":"植物材料、种子","test_object_cs":"Rostlinný materiál, osivo","methodology":"Wykrywanie wirusów roślin testem biologicznym","methodology_en":"Detection of plant viruses by bioassay","methodology_zh":"生物测定法检测植物病毒","methodology_cs":"Detekce rostlinných virů biologickým testem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie wirusów roślin testem biologicznym","reference":"SOP-M-01, mimo kap. 7.1","norm_bases":["SOP-M-01"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: PM 7/153 Mechanical inoculation of test plants. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: PM 7/153 Mechanical inoculation of test plants. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：PM 7/153 Mechanical inoculation of test plants.相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: PM 7/153 Mechanical inoculation of test plants. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, materiał siewny Wykrywanie wirusów roślin testem biologicznym Rostlinný materiál, osivo Detekce rostlinných virů biologickým testem SOP-M-01, mimo kap. 7.1 Material roslinny, material siewny Wykrywanie wirusow roslin testem biologicznym Rostlinny material, osivo Detekce rostlinnych viru biologickym testem SOP-M-01, mimo kap. 7.1","search_en":"Plant material, seed Detection of plant viruses by bioassay SOP-M-01, mimo kap. 7.1","search_zh":"植物材料、种子 生物测定法检测植物病毒 SOP-M-01, mimo kap. 7.1","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":203,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6e1314dc6e396b459272153f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"3","test_object":"Materiał roślinny, materiał siewny, podłoża, gleba, kultury grzybów i organizmów grzybopodobnych, woda, owocniki","test_object_en":"Plant material, seed, substrates, soil, cultures of fungal and fungi-like organisms, water, fruiting bodies","test_object_zh":"植物材料、种子、基质、土壤、真菌及类真菌生物培养物、水、子实体","test_object_cs":"Rostlinný materiál, osivo, substráty, půda, kultury houbových a houbám podobných organismů, voda, plodnice","methodology":"Wykrywanie i identyfikacja grzybów i organizmów grzybopodobnych metodą mikroskopii świetlnej","methodology_en":"Detection and identification of fungal and fungi-like organisms by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定真菌及类真菌生物","methodology_cs":"Detekce a identifikace houbových a houbám podobných organismů metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja grzybów i organizmów grzybopodobnych metodą mikroskopii świetlnej","reference":"SOP-M-06, mimo kap. 7.2.4","norm_bases":["SOP-M-06"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: CBS Course of Mycology, W. Gams, E.S. Hoekstra, A. Aptroot, wyd. 4, 1998, ISBN 90-70351-36-6, Basic Plant Pathology Methods, O.D. Dhingra, J.B. Sinclair, wyd. 2, 1995, SBN0-87371-638-8, Černý Alois (1989): Parazitické dřevokazné houby, Státní zemědělské nakladatelství Praha, 104 strony. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: CBS Course of Mycology, W. Gams, E.S. Hoekstra, A. Aptroot, 4th Edition 1998, ISBN 90-70351-36-6, Basic Plant Pathology Methods, O.D. Dhingra, J.B. Sinclair, 2nd Edition, 1995, SBN0-87371-638-8, Černý Alois (1989): Parazitické dřevokazné houby, Státní zemědělské nakladatelství Praha, 104 pages. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：CBS Course of Mycology, W. Gams, E.S. Hoekstra, A. Aptroot, 第4版 1998, ISBN 90-70351-36-6, Basic Plant Pathology Methods, O.D. Dhingra, J.B. Sinclair, 第2版, 1995, SBN0-87371-638-8, Černý Alois (1989): Parazitické dřevokazné houby, Státní zemědělské nakladatelství Praha, 104页。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: CBS Course of Mycology, W. Gams, E.S. Hoekstra, A. Aptroot, 4. vydání 1998, ISBN 90-70351-36-6, Basic Plant Pathology Methods, O.D. Dhingra, J.B. Sinclair, 2. vydání, 1995, SBN0-87371-638-8, Černý Alois (1989): Parazitické dřevokazné houby, Státní zemědělské nakladatelství Praha, 104 stran. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, materiał siewny, podłoża, gleba, kultury grzybów i organizmów grzybopodobnych, woda, owocniki Wykrywanie i identyfikacja grzybów i organizmów grzybopodobnych metodą mikroskopii świetlnej Rostlinný materiál, osivo, substráty, půda, kultury houbových a houbám podobných organismů, voda, plodnice Detekce a identifikace houbových a houbám podobných organismů metodou světelné mikroskopie SOP-M-06, mimo kap. 7.2.4 Material roslinny, material siewny, podloza, gleba, kultury grzybow i organizmow grzybopodobnych, woda, owocniki Wykrywanie i identyfikacja grzybow i organizmow grzybopodobnych metoda mikroskopii swietlnej Rostlinny material, osivo, substraty, puda, kultury houbovych a houbam podobnych organismu, voda, plodnice Detekce a identifikace houbovych a houbam podobnych organismu metodou svetelne mikroskopie SOP-M-06, mimo kap. 7.2.4","search_en":"Plant material, seed, substrates, soil, cultures of fungal and fungi-like organisms, water, fruiting bodies Detection and identification of fungal and fungi-like organisms by light microscopy method SOP-M-06, mimo kap. 7.2.4","search_zh":"植物材料、种子、基质、土壤、真菌及类真菌生物培养物、水、子实体 光学显微镜法检测和鉴定真菌及类真菌生物 SOP-M-06, mimo kap. 7.2.4","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":204,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1fee5ac88f8ebecf2e4354a3","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"4","test_object":"Materiał roślinny, materiał siewny, kultury grzybów i organizmów grzybopodobnych, owocniki","test_object_en":"Plant material, seed, cultures of fungal and fungi-like organisms, fruiting bodies","test_object_zh":"植物材料、种子、真菌及类真菌生物培养物、子实体","test_object_cs":"Rostlinný materiál, osivo, kultury houbových a houbám podobných organismů, plodnice","methodology":"Wykrywanie i identyfikacja grzybów i organizmów grzybopodobnych metodą hodowlaną","methodology_en":"Detection and identification of fungal and fungi-like organisms by cultivation method","methodology_zh":"培养法检测和鉴定真菌及类真菌生物","methodology_cs":"Detekce a identifikace houbových a houbám podobných organismů metodou kultivace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja grzybów i organizmów grzybopodobnych metodą hodowlaną","reference":"SOP-M-06, mimo kap. 7.2.4, 7.2.5","norm_bases":["SOP-M-06"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: CBS Course of Mycology, W. Gams, E.S. Hoekstra, A. Aptroot, wyd. 4, 1998, ISBN 90-70351-36-6, Basic Plant Pathology Methods, O.D. Dhingra, J.B. Sinclair, wyd. 2, 1995, SBN0-87371-638-8, Černý Alois (1989): Parazitické dřevokazné houby, Státní zemědělské nakladatelství Praha, 104 strony. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: CBS Course of Mycology, W. Gams, E.S. Hoekstra, A. Aptroot, 4th Edition 1998, ISBN 90-70351-36-6, Basic Plant Pathology Methods, O.D. Dhingra, J.B. Sinclair, 2nd Edition, 1995, SBN0-87371-638-8, Černý Alois (1989): Parazitické dřevokazné houby, Státní zemědělské nakladatelství Praha, 104 pages. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：CBS Course of Mycology, W. Gams, E.S. Hoekstra, A. Aptroot, 第4版 1998, ISBN 90-70351-36-6, Basic Plant Pathology Methods, O.D. Dhingra, J.B. Sinclair, 第2版, 1995, SBN0-87371-638-8, Černý Alois (1989): Parazitické dřevokazné houby, Státní zemědělské nakladatelství Praha, 104页。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: CBS Course of Mycology, W. Gams, E.S. Hoekstra, A. Aptroot, 4. vydání 1998, ISBN 90-70351-36-6, Basic Plant Pathology Methods, O.D. Dhingra, J.B. Sinclair, 2. vydání, 1995, SBN0-87371-638-8, Černý Alois (1989): Parazitické dřevokazné houby, Státní zemědělské nakladatelství Praha, 104 stran. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, materiał siewny, kultury grzybów i organizmów grzybopodobnych, owocniki Wykrywanie i identyfikacja grzybów i organizmów grzybopodobnych metodą hodowlaną Rostlinný materiál, osivo, kultury houbových a houbám podobných organismů, plodnice Detekce a identifikace houbových a houbám podobných organismů metodou kultivace SOP-M-06, mimo kap. 7.2.4, 7.2.5 Material roslinny, material siewny, kultury grzybow i organizmow grzybopodobnych, owocniki Wykrywanie i identyfikacja grzybow i organizmow grzybopodobnych metoda hodowlana Rostlinny material, osivo, kultury houbovych a houbam podobnych organismu, plodnice Detekce a identifikace houbovych a houbam podobnych organismu metodou kultivace SOP-M-06, mimo kap. 7.2.4, 7.2.5","search_en":"Plant material, seed, cultures of fungal and fungi-like organisms, fruiting bodies Detection and identification of fungal and fungi-like organisms by cultivation method SOP-M-06, mimo kap. 7.2.4, 7.2.5","search_zh":"植物材料、种子、真菌及类真菌生物培养物、子实体 培养法检测和鉴定真菌及类真菌生物 SOP-M-06, mimo kap. 7.2.4, 7.2.5","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":205,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5c334150a3cb6d603a583ffa","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"5","test_object":"Materiał roślinny, materiał siewny, podłoża, gleba, woda","test_object_en":"Plant material, seed, substrates, soil, water","test_object_zh":"植物材料、种子、基质、土壤、水","test_object_cs":"Rostlinný materiál, osivo, substráty, půda, voda","methodology":"Wykrywanie i identyfikacja grzybów i organizmów grzybopodobnych testem biologicznym","methodology_en":"Detection and identification of fungal and fungi-like organisms by biological test","methodology_zh":"生物测定法检测和鉴定真菌及类真菌生物","methodology_cs":"Detekce a identifikace houbových a houbám podobných organismů biologickým testem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja grzybów i organizmów grzybopodobnych testem biologicznym","reference":"SOP-M-06, mimo kap. 7.2.1, 7.2.2, 7.2.3, 7.2.5","norm_bases":["SOP-M-06"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: CBS Course of Mycology, W. Gams, E.S. Hoekstra, A. Aptroot, wyd. 4, 1998, ISBN 90-70351-36-6, Basic Plant Pathology Methods, O.D. Dhingra, J.B. Sinclair, wyd. 2, 1995, SBN0-87371-638-8. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics Właściwe procedury wg ISTA: https://www.seedtest.org/en/seed-health-methods-_content---1--1452.html","note_en":"Source literature: CBS Course of Mycology, W. Gams, E.S. Hoekstra, A. Aptroot, 4th Edition 1998, ISBN 90-70351-36-6, Basic Plant Pathology Methods, O.D. Dhingra, J.B. Sinclair, 2nd Edition, 1995, SBN0-87371-638-8. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics Relevant procedures pursuant to ISTA: https://www.seedtest.org/en/seed-health-methods-_content---1--1452.html","note_zh":"参考文献：CBS Course of Mycology, W. Gams, E.S. Hoekstra, A. Aptroot, 第4版 1998, ISBN 90-70351-36-6, Basic Plant Pathology Methods, O.D. Dhingra, J.B. Sinclair, 第2版, 1995, SBN0-87371-638-8。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics相关ISTA程序：https://www.seedtest.org/en/seed-health-methods-_content---1--1452.html","note_cs":"Zdrojová literatura: CBS Course of Mycology, W. Gams, E.S. Hoekstra, A. Aptroot, 4. vydání 1998, ISBN 90-70351-36-6, Basic Plant Pathology Methods, O.D. Dhingra, J.B. Sinclair, 2. vydání, 1995, SBN0-87371-638-8. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics Příslušné postupy dle ISTA: https://www.seedtest.org/en/seed-health-methods-_content---1--1452.html","search_text":"Materiał roślinny, materiał siewny, podłoża, gleba, woda Wykrywanie i identyfikacja grzybów i organizmów grzybopodobnych testem biologicznym Rostlinný materiál, osivo, substráty, půda, voda Detekce a identifikace houbových a houbám podobných organismů biologickým testem SOP-M-06, mimo kap. 7.2.1, 7.2.2, 7.2.3, 7.2.5 Material roslinny, material siewny, podloza, gleba, woda Wykrywanie i identyfikacja grzybow i organizmow grzybopodobnych testem biologicznym Rostlinny material, osivo, substraty, puda, voda Detekce a identifikace houbovych a houbam podobnych organismu biologickym testem SOP-M-06, mimo kap. 7.2.1, 7.2.2, 7.2.3, 7.2.5","search_en":"Plant material, seed, substrates, soil, water Detection and identification of fungal and fungi-like organisms by biological test SOP-M-06, mimo kap. 7.2.1, 7.2.2, 7.2.3, 7.2.5","search_zh":"植物材料、种子、基质、土壤、水 生物测定法检测和鉴定真菌及类真菌生物 SOP-M-06, mimo kap. 7.2.1, 7.2.2, 7.2.3, 7.2.5","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":206,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"de096ce60399f1d5ef9c0455","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"6","test_object":"Materiał roślinny, materiał siewny","test_object_en":"Plant material, seed","test_object_zh":"植物材料、种子","test_object_cs":"Rostlinný materiál, osivo","methodology":"Wykrywanie i identyfikacja wybranych gatunków z rodzaju Tilletia metodą mikroskopii świetlnej","methodology_en":"Detection and identification of selected species of the genus Tilletia by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定腥黑粉菌属（Tilletia）选定种类","methodology_cs":"Detekce a identifikace vybraných druhů rodu Tilletia metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja wybranych gatunków z rodzaju Tilletia metodą mikroskopii świetlnej","reference":"SOP-M-44","norm_bases":["SOP-M-44"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wykaz identyfikowanych gatunków z rodzaju Tilletia: Tilletia controversa, Tilletia tritici, Tilletia indica, Tilletia foetida Literatura źródłowa: Kochanová, M., Prokinová, E., Metody diagnostiky Tilletia spp. v teorii a praxi, 2004, ČFS. 68 s. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"List of identified species of the genus Tilletia: Tilletia controversa, Tilletia tritici, Tilletia indica, Tilletia foetida Source literature: Kochanová, M., Prokinová, E., Metody diagnostiky Tilletia spp. v teorii a praxi, 2004, ČFS. 68 p. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"鉴定的腥黑粉菌属（Tilletia）种类清单：Tilletia controversa, Tilletia tritici, Tilletia indica, Tilletia foetida参考文献：Kochanová, M., Prokinová, E., Metody diagnostiky Tilletia spp. v teorii a praxi, 2004, ČFS. 68页。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Seznam identifikovaných druhů z rodu Tilletia: Tilletia controversa, Tilletia tritici, Tilletia indica, Tilletia foetida Zdrojová literatura: Kochanová, M., Prokinová, E., Metody diagnostiky Tilletia spp. v teorii a praxi, 2004, ČFS. 68 p. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, materiał siewny Wykrywanie i identyfikacja wybranych gatunków z rodzaju Tilletia metodą mikroskopii świetlnej Rostlinný materiál, osivo Detekce a identifikace vybraných druhů rodu Tilletia metodou světelné mikroskopie SOP-M-44 Material roslinny, material siewny Wykrywanie i identyfikacja wybranych gatunkow z rodzaju Tilletia metoda mikroskopii swietlnej Rostlinny material, osivo Detekce a identifikace vybranych druhu rodu Tilletia metodou svetelne mikroskopie SOP-M-44","search_en":"Plant material, seed Detection and identification of selected species of the genus Tilletia by light microscopy method SOP-M-44","search_zh":"植物材料、种子 光学显微镜法检测和鉴定腥黑粉菌属（Tilletia）选定种类 SOP-M-44","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":207,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c5596ec94b2b061810b26163","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"7","test_object":"Materiał roślinny, kultury bakteryjne, materiał siewny, gleba","test_object_en":"Plant material, bacterial cultures, seed, soil","test_object_zh":"植物材料、细菌培养物、种子、土壤","test_object_cs":"Rostlinný materiál, bakteriální kultury, osivo, půda","methodology":"Wykrywanie, identyfikacja i potwierdzanie obecności bakterii fitopatogennych metodą hodowlaną","methodology_en":"Detection, identification and presence confirmation of phytopathogenic bacteria by cultivation method","methodology_zh":"培养法检测、鉴定和确认植物病原细菌","methodology_cs":"Detekce, identifikace a konfirmace přítomnosti fytopatogenních bakterií metodou kultivace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie, identyfikacja i potwierdzanie obecności bakterii fitopatogennych metodą hodowlaną","reference":"SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.5, 7.3.6","norm_bases":["SOP-M-48"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: Właściwe procedury wg ISTA: https://www.seedtest.org/en/seed-health-methods-_content---1--1452.html Kůdela, V., Novacky, A., & Fucikovsky, L. (2002). Rostlinolékařská bakteriologie. Academia. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: Relevant procedures pursuant to ISTA: https://www.seedtest.org/en/seed-health-methods-_content---1--1452.html Kůdela, V., Novacky, A., & Fucikovsky, L. (2002). Rostlinolékařská bakteriologie. Academia. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：相关ISTA程序：https://www.seedtest.org/en/seed-health-methods-_content---1--1452.htmlKůdela, V., Novacky, A., & Fucikovsky, L. (2002). Rostlinolékařská bakteriologie. Academia.相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: Příslušné postupy dle ISTA: https://www.seedtest.org/en/seed-health-methods-_content---1--1452.html Kůdela, V., Novacky, A., & Fucikovsky, L. (2002). Rostlinolékařská bakteriologie. Academia. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, kultury bakteryjne, materiał siewny, gleba Wykrywanie, identyfikacja i potwierdzanie obecności bakterii fitopatogennych metodą hodowlaną Rostlinný materiál, bakteriální kultury, osivo, půda Detekce, identifikace a konfirmace přítomnosti fytopatogenních bakterií metodou kultivace SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.5, 7.3.6 Material roslinny, kultury bakteryjne, material siewny, gleba Wykrywanie, identyfikacja i potwierdzanie obecnosci bakterii fitopatogennych metoda hodowlana Rostlinny material, bakterialni kultury, osivo, puda Detekce, identifikace a konfirmace pritomnosti fytopatogennich bakterii metodou kultivace SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.5, 7.3.6","search_en":"Plant material, bacterial cultures, seed, soil Detection, identification and presence confirmation of phytopathogenic bacteria by cultivation method SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.5, 7.3.6","search_zh":"植物材料、细菌培养物、种子、土壤 培养法检测、鉴定和确认植物病原细菌 SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.5, 7.3.6","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":208,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5f77a17d6d0b1ca6bc59afd0","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"9","test_object":"Materiał roślinny, kultury bakteryjne, materiał siewny, gleba","test_object_en":"Plant material, bacterial cultures, seed, soil","test_object_zh":"植物材料、细菌培养物、种子、土壤","test_object_cs":"Rostlinný materiál, bakteriální kultury, osivo, půda","methodology":"Wykrywanie, identyfikacja i potwierdzanie obecności bakterii fitopatogennych metodą spektrofotometryczną BIOLOG","methodology_en":"Detection, identification and presence confirmation of phytopathogenic bacteria by BIOLOG spectrophotometric method","methodology_zh":"BIOLOG分光光度法检测、鉴定和确认植物病原细菌","methodology_cs":"Detekce, identifikace a konfirmace přítomnosti fytopatogenních bakterií spektrofotometricky metodou BIOLOG","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie, identyfikacja i potwierdzanie obecności bakterii fitopatogennych metodą spektrofotometryczną BIOLOG","reference":"SOP-M-48, mimo kap. 7.3.3, 7.3.5, 7.3.6","norm_bases":["SOP-M-48"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: BIOLOG MicrostationTM System/MicrologTM User´s Guide. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: BIOLOG MicrostationTM System/MicrologTM User´s Guide. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：BIOLOG MicrostationTM System/MicrologTM User´s Guide.相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: BIOLOG MicrostationTM Systém/MicrologTM User´s Guide. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, kultury bakteryjne, materiał siewny, gleba Wykrywanie, identyfikacja i potwierdzanie obecności bakterii fitopatogennych metodą spektrofotometryczną BIOLOG Rostlinný materiál, bakteriální kultury, osivo, půda Detekce, identifikace a konfirmace přítomnosti fytopatogenních bakterií spektrofotometricky metodou BIOLOG SOP-M-48, mimo kap. 7.3.3, 7.3.5, 7.3.6 Material roslinny, kultury bakteryjne, material siewny, gleba Wykrywanie, identyfikacja i potwierdzanie obecnosci bakterii fitopatogennych metoda spektrofotometryczna BIOLOG Rostlinny material, bakterialni kultury, osivo, puda Detekce, identifikace a konfirmace pritomnosti fytopatogennich bakterii spektrofotometricky metodou BIOLOG SOP-M-48, mimo kap. 7.3.3, 7.3.5, 7.3.6","search_en":"Plant material, bacterial cultures, seed, soil Detection, identification and presence confirmation of phytopathogenic bacteria by BIOLOG spectrophotometric method SOP-M-48, mimo kap. 7.3.3, 7.3.5, 7.3.6","search_zh":"植物材料、细菌培养物、种子、土壤 BIOLOG分光光度法检测、鉴定和确认植物病原细菌 SOP-M-48, mimo kap. 7.3.3, 7.3.5, 7.3.6","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":209,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a6f01d1354040d2674d87342","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"10","test_object":"Materiał roślinny, kultury bakteryjne, materiał siewny, gleba","test_object_en":"Plant material, bacterial cultures, seed, soil","test_object_zh":"植物材料、细菌培养物、种子、土壤","test_object_cs":"Rostlinný materiál, bakteriální kultury, osivo, půda","methodology":"Wykrywanie, identyfikacja i potwierdzanie obecności bakterii fitopatogennych metodą spektrometrii mas MALDI-TOF","methodology_en":"Detection, identification and presence confirmation of phytopathogenic bacteria by MALDI-TOF mass spectrometry method","methodology_zh":"MALDI-TOF质谱法检测、鉴定和确认植物病原细菌","methodology_cs":"Detekce, identifikace a konfirmace přítomnosti fytopatogenních bakterií metodou hmotnostní spektrometrie MALDI-TOF","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie, identyfikacja i potwierdzanie obecności bakterii fitopatogennych metodą spektrometrii mas MALDI-TOF","reference":"SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.6","norm_bases":["SOP-M-48"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: Instrukcja użytkownika MALDI biotyper Sirius firmy Bruker. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: MALDI biotyper Sirius user manual by Bruker. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：Bruker公司MALDI biotyper Sirius用户手册。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: MALDI biotyper Sirius uživatelský manuál od firmy Bruker. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, kultury bakteryjne, materiał siewny, gleba Wykrywanie, identyfikacja i potwierdzanie obecności bakterii fitopatogennych metodą spektrometrii mas MALDI-TOF Rostlinný materiál, bakteriální kultury, osivo, půda Detekce, identifikace a konfirmace přítomnosti fytopatogenních bakterií metodou hmotnostní spektrometrie MALDI-TOF SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.6 Material roslinny, kultury bakteryjne, material siewny, gleba Wykrywanie, identyfikacja i potwierdzanie obecnosci bakterii fitopatogennych metoda spektrometrii mas MALDI-TOF Rostlinny material, bakterialni kultury, osivo, puda Detekce, identifikace a konfirmace pritomnosti fytopatogennich bakterii metodou hmotnostni spektrometrie MALDI-TOF SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.6","search_en":"Plant material, bacterial cultures, seed, soil Detection, identification and presence confirmation of phytopathogenic bacteria by MALDI-TOF mass spectrometry method SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.6","search_zh":"植物材料、细菌培养物、种子、土壤 MALDI-TOF质谱法检测、鉴定和确认植物病原细菌 SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.6","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":210,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5b4bbc35879b28977ada1e27","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"11","test_object":"Materiał roślinny, kultury bakteryjne, materiał siewny, gleba","test_object_en":"Plant material, bacterial cultures, seed, soil","test_object_zh":"植物材料、细菌培养物、种子、土壤","test_object_cs":"Rostlinný materiál, bakteriální kultury, osivo, půda","methodology":"Wykrywanie, identyfikacja i potwierdzanie obecności bakterii fitopatogennych testem biologicznym","methodology_en":"Detection, identification and presence confirmation of phytopathogenic bacteria by biological test","methodology_zh":"生物测定法检测、鉴定和确认植物病原细菌","methodology_cs":"Detekce, identifikace a konfirmace přítomnosti fytopatogenních bakterií biologickým testem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie, identyfikacja i potwierdzanie obecności bakterii fitopatogennych testem biologicznym","reference":"SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.5","norm_bases":["SOP-M-48"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: Właściwe procedury wg ISTA: https://www.seedtest.org/en/seed-health-methods-_content---1--1452.html Kůdela, V., Novacky, A., & Fucikovsky, L. (2002). Rostlinolékařská bakteriologie. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: Relevant procedures pursuant to ISTA: https://www.seedtest.org/en/seed-health-methods-_content---1--1452.html Kůdela, V., Novacky, A., & Fucikovsky, L. (2002). Rostlinolékařská bakteriologie. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：相关ISTA程序：https://www.seedtest.org/en/seed-health-methods-_content---1--1452.htmlKůdela, V., Novacky, A., & Fucikovsky, L. (2002). Rostlinolékařská bakteriologie.相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: Příslušné postupy dle ISTA: https://www.seedtest.org/en/seed-health-methods-_content---1--1452.html Kůdela, V., Novacky, A., & Fucikovsky, L. (2002). Rostlinolékařská bakteriologie. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, kultury bakteryjne, materiał siewny, gleba Wykrywanie, identyfikacja i potwierdzanie obecności bakterii fitopatogennych testem biologicznym Rostlinný materiál, bakteriální kultury, osivo, půda Detekce, identifikace a konfirmace přítomnosti fytopatogenních bakterií biologickým testem SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.5 Material roslinny, kultury bakteryjne, material siewny, gleba Wykrywanie, identyfikacja i potwierdzanie obecnosci bakterii fitopatogennych testem biologicznym Rostlinny material, bakterialni kultury, osivo, puda Detekce, identifikace a konfirmace pritomnosti fytopatogennich bakterii biologickym testem SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.5","search_en":"Plant material, bacterial cultures, seed, soil Detection, identification and presence confirmation of phytopathogenic bacteria by biological test SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.5","search_zh":"植物材料、细菌培养物、种子、土壤 生物测定法检测、鉴定和确认植物病原细菌 SOP-M-48, mimo kap. 7.3.3, 7.3.4, 7.3.5","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":211,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5d1e051e88717d4751ddb9b4","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"12","test_object":"Materiał roślinny, drewno, materiał siewny, podłoża, gleba, owady, osady, nicienie","test_object_en":"Plant material, wood, seed, substrates, soil, insects, sludge, nematodes","test_object_zh":"植物材料、木材、种子、基质、土壤、昆虫、污泥、线虫","test_object_cs":"Rostlinný materiál, dřevo, osivo, substráty, půda, hmyz, kaly, hlístice","methodology":"Wykrywanie i identyfikacja nicieni fitofagicznych, mykofagicznych i wolno żyjących metodą mikroskopii świetlnej","methodology_en":"Detection and identification of phytophagous, mycophagous and free-living nematodes by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定植食性、食菌性和自由生活线虫","methodology_cs":"Detekce a identifikace fytofágních, mykofágních a volně žijících hlístic metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja nicieni fitofagicznych, mykofagicznych i wolno żyjących metodą mikroskopii świetlnej","reference":"SOP-M-81","norm_bases":["SOP-M-81"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp.相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, drewno, materiał siewny, podłoża, gleba, owady, osady, nicienie Wykrywanie i identyfikacja nicieni fitofagicznych, mykofagicznych i wolno żyjących metodą mikroskopii świetlnej Rostlinný materiál, dřevo, osivo, substráty, půda, hmyz, kaly, hlístice Detekce a identifikace fytofágních, mykofágních a volně žijících hlístic metodou světelné mikroskopie SOP-M-81 Material roslinny, drewno, material siewny, podloza, gleba, owady, osady, nicienie Wykrywanie i identyfikacja nicieni fitofagicznych, mykofagicznych i wolno zyjacych metoda mikroskopii swietlnej Rostlinny material, drevo, osivo, substraty, puda, hmyz, kaly, hlistice Detekce a identifikace fytofagnich, mykofagnich a volne zijicich hlistic metodou svetelne mikroskopie SOP-M-81","search_en":"Plant material, wood, seed, substrates, soil, insects, sludge, nematodes Detection and identification of phytophagous, mycophagous and free-living nematodes by light microscopy method SOP-M-81","search_zh":"植物材料、木材、种子、基质、土壤、昆虫、污泥、线虫 光学显微镜法检测和鉴定植食性、食菌性和自由生活线虫 SOP-M-81","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":212,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2c52a02217bc39d9c9ba37bb","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"13","test_object":"Podłoża, gleba, wody z płukania, osady, nicienie","test_object_en":"Substrates, soil, rinse water, sludge, nematodes","test_object_zh":"基质、土壤、冲洗水、污泥、线虫","test_object_cs":"Substráty, půda, oplachové vody, kaly, hlístice","methodology":"Wykrywanie cyst i identyfikacja mątwika ziemniaczanego (Globodera rostochiensis) i mątwika agresywnego (Globodera pallida) metodą mikroskopii świetlnej","methodology_en":"Detection of cysts and identification of potato cyst nematode (Globodera rostochiensis) and white potato cyst nematode (Globodera pallida) by light microscopy method","methodology_zh":"光学显微镜法检测孢囊并鉴定马铃薯金线虫（Globodera rostochiensis）和马铃薯白线虫（Globodera pallida）","methodology_cs":"Detekce cyst a identifikace háďátka bramborového (Globodera rostochiensis) a háďátka nažloutlého (Globodera pallida) metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie cyst i identyfikacja mątwika ziemniaczanego (Globodera rostochiensis) i mątwika agresywnego (Globodera pallida) metodą mikroskopii świetlnej","reference":"SOP-M-82","norm_bases":["SOP-M-82"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: Rozporządzenie wykonawcze Komisji (UE) 2022/1192 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Globodera pallida (Stone) Behrens i Globodera rostochiensis (Wollenweber) Behrens. Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp., EPPO PM 7/40 Globodera rostochiensis and G. pallida.","note_en":"Source literature: Commission Implementing Regulation (EU) 2022/1192 of 11 July 2022 establishing measures to eradicate and prevent the spread of Globodera pallida (Stone) Behrens and Globodera rostochiensis (Wollenweber) Behrens. Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp., EPPO PM 7/40 Globodera rostochiensis and G. pallida.","note_zh":"参考文献：2022年7月11日委员会实施条例（EU）2022/1192，规定根除和防止Globodera pallida (Stone) Behrens和Globodera rostochiensis (Wollenweber) Behrens传播的措施。Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp., EPPO PM 7/40 Globodera rostochiensis and G. pallida.","note_cs":"Zdrojová literatura: PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1192 ze dne 11.července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismů Globodera pallida (Stone) Behrens a Globodera rostochiensis (Wollenweber) Behrens. Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp., EPPO PM 7/40 Globodera rostochiensis and G. pallida.","search_text":"Podłoża, gleba, wody z płukania, osady, nicienie Wykrywanie cyst i identyfikacja mątwika ziemniaczanego (Globodera rostochiensis) i mątwika agresywnego (Globodera pallida) metodą mikroskopii świetlnej Substráty, půda, oplachové vody, kaly, hlístice Detekce cyst a identifikace háďátka bramborového (Globodera rostochiensis) a háďátka nažloutlého (Globodera pallida) metodou světelné mikroskopie SOP-M-82 Podloza, gleba, wody z plukania, osady, nicienie Wykrywanie cyst i identyfikacja matwika ziemniaczanego (Globodera rostochiensis) i matwika agresywnego (Globodera pallida) metoda mikroskopii swietlnej Substraty, puda, oplachove vody, kaly, hlistice Detekce cyst a identifikace hadatka bramboroveho (Globodera rostochiensis) a hadatka nazloutleho (Globodera pallida) metodou svetelne mikroskopie SOP-M-82","search_en":"Substrates, soil, rinse water, sludge, nematodes Detection of cysts and identification of potato cyst nematode (Globodera rostochiensis) and white potato cyst nematode (Globodera pallida) by light microscopy method SOP-M-82","search_zh":"基质、土壤、冲洗水、污泥、线虫 光学显微镜法检测孢囊并鉴定马铃薯金线虫（Globodera rostochiensis）和马铃薯白线虫（Globodera pallida） SOP-M-82","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":213,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"df04f1d2803eb5d46417ec25","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"14","test_object":"Materiał roślinny, materiał siewny, podłoża, gleba, osady, nicienie","test_object_en":"Plant material, seed, substrates, soil, sludge, nematodes","test_object_zh":"植物材料、种子、基质、土壤、污泥、线虫","test_object_cs":"Rostlinný materiál, osivo, substráty, půda, kaly, hlístice","methodology":"Wykrywanie i identyfikacja niszczyka Ditylenchus dipsaci i Ditylenchus destructor metodą mikroskopii świetlnej","methodology_en":"Detection and identification of Ditylenchus dipsaci and Ditylenchus destructor by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定鳞球茎茎线虫（Ditylenchus dipsaci）和腐烂茎线虫（Ditylenchus destructor）","methodology_cs":"Detekce a identifikace háďátka Ditylenchus dipsaci a Ditylenchus destructor metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja niszczyka Ditylenchus dipsaci i Ditylenchus destructor metodą mikroskopii świetlnej","reference":"SOP-M-83","norm_bases":["SOP-M-83"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Literatura źródłowa: EPPO PM 7/87 Ditylenchus destructor and Ditylenchus dipsaci, Brzeski M. W. (1998): Nematodes of Tylenchina in Poland and temperate Europe. Muzeum i Instytut Zoologii Polska Akademia Nauk, Warsaw, Poland, 395 pp.","note_en":"Source literature: EPPO PM 7/87 Ditylenchus destructor and Ditylenchus dipsaci, Brzeski M. W. (1998): Nematodes of Tylenchina in Poland and temperate Europe. Muzeum i Instytut Zoologii Polska Akademia Nauk, Warsaw, Poland, 395 pp.","note_zh":"参考文献：EPPO PM 7/87 Ditylenchus destructor and Ditylenchus dipsaci, Brzeski M. W. (1998): Nematodes of Tylenchina in Poland and temperate Europe. Muzeum i Instytut Zoologii Polska Akademia Nauk, Warsaw, Poland, 395 pp.","note_cs":"Zdrojová literatura: EPPO PM 7/87 Ditylenchus destructor and Ditylenchus dipsaci, Brzeski M. W. (1998): Nematodes of Tylenchina in Poland and temperate Europe. Muzeum i Instytut Zoologii Polska Akademia Nauk, Warsaw, Poland, 395 pp.","search_text":"Materiał roślinny, materiał siewny, podłoża, gleba, osady, nicienie Wykrywanie i identyfikacja niszczyka Ditylenchus dipsaci i Ditylenchus destructor metodą mikroskopii świetlnej Rostlinný materiál, osivo, substráty, půda, kaly, hlístice Detekce a identifikace háďátka Ditylenchus dipsaci a Ditylenchus destructor metodou světelné mikroskopie SOP-M-83 Material roslinny, material siewny, podloza, gleba, osady, nicienie Wykrywanie i identyfikacja niszczyka Ditylenchus dipsaci i Ditylenchus destructor metoda mikroskopii swietlnej Rostlinny material, osivo, substraty, puda, kaly, hlistice Detekce a identifikace hadatka Ditylenchus dipsaci a Ditylenchus destructor metodou svetelne mikroskopie SOP-M-83","search_en":"Plant material, seed, substrates, soil, sludge, nematodes Detection and identification of Ditylenchus dipsaci and Ditylenchus destructor by light microscopy method SOP-M-83","search_zh":"植物材料、种子、基质、土壤、污泥、线虫 光学显微镜法检测和鉴定鳞球茎茎线虫（Ditylenchus dipsaci）和腐烂茎线虫（Ditylenchus destructor） SOP-M-83","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":214,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"99cb6b17a68a98b6b89c47ff","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"15","test_object":"Materiał roślinny, materiał siewny, grzyby i organizmy grzybopodobne, bakterie, stawonogi, nicienie, wody do nawadniania i ścieki, gleba, DNA i RNA","test_object_en":"Plant material, seed, fungi and fungi-like organisms, bacteria, arthropods, nematodes, irrigation and wastewater, soil, DNA and RNA","test_object_zh":"植物材料、种子、真菌及类真菌生物、细菌、节肢动物、线虫、灌溉水和废水、土壤、DNA和RNA","test_object_cs":"Rostlinný materiál, osivo, houby a houbám podobné organismy, bakterie, členovci, hlístice, závlahové a odpadní vody, půda, DNA a RNA","methodology":"Wykrywanie i identyfikacja organizmów szkodliwych dla roślin metodą real-time PCR","methodology_en":"Detection and identification of plant pests by real-time PCR method","methodology_zh":"实时荧光PCR法检测和鉴定植物有害生物","methodology_cs":"Detekce a identifikace škodlivých organismů rostlin metodou real-time PCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja organizmów szkodliwych dla roślin metodą real-time PCR","reference":"SOP-M-30","norm_bases":["SOP-M-30"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Wykaz badanych organizmów: Bakterie: Candidatus Arsenophonus phytopathogenicus, Candidatus Liberibacter africanus, Candidatus Liberibacter americanus, Candidatus Liberibacter asiaticus, Candidatus Liberibacter solanacearum, Clavibacter insidiosus, Curtobacterium flaccumfaciens pv. Flaccumfaciens, Erwinia amylovora, Xylella fastidiosa, Xylella fastidiosa subsp. fastidiosa, Xylella fastidiosa subsp. morus, Xylella fastidiosa subsp. multiplex, Xylella fastidiosa subsp. pauca, Xylella fastidiosa subsp. sandyi, Xanthomonas campestris. Fitoplazmy Grzyby: Verticillium nonalfalfae, Verticillium dahliae, Synchytrium endobioticum Wirusy: blackcurrant reversion virus, chrysanthemum stem necrosis virus, gooseberry vein banding associated virus, little cherry virus 1, little cherry virus 2, olive latent virus 1, pepino mosaic virus, rose rosette virus, strawberry mild yellow edge virus, strawberry crinkle virus, strawberry virus 1, strawberry vein banding virus, strawberry mottle virus, strawberry polerovirus 1, tomato brown rugose fruit virus, tomato chlorosis virus, tomato infectious chlorosis virus, tomato mottle mosaic virus, tomato ringspot virus. Literatura źródłowa: Rozporządzenie wykonawcze Komisji (UE) 2020/1191 z dnia 11 sierpnia 2020 r. ustanawiające środki zapobiegające wprowadzaniu do Unii i rozprzestrzenianiu się w Unii wirusa Tomato brown rugose fruit virus (ToBRFV) oraz uchylające decyzję wykonawczą (UE) 2019/1615, z późniejszymi zmianami. Rozporządzenie wykonawcze Komisji (UE) 2020/1201 z dnia 14 sierpnia 2020 r. w sprawie środków zapobiegających wprowadzaniu do Unii i rozprzestrzenianiu się w Unii Xylella fastidiosa (Wells et al.), z późniejszymi zmianami. Wykaz literatury źródłowej we właściwych procedurach roboczych. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"List of organisms tested: Bacteria: Candidatus Arsenophonus phytopathogenicus, Candidatus Liberibacter africanus, Candidatus Liberibacter americanus, Candidatus Liberibacter asiaticus, Candidatus Liberibacter solanacearum, Clavibacter insidiosus, Curtobacterium flaccumfaciens pv. Flaccumfaciens, Erwinia amylovora, Xylella fastidiosa, Xylella fastidiosa subsp. fastidiosa, Xylella fastidiosa subsp. morus, Xylella fastidiosa subsp. multiplex, Xylella fastidiosa subsp. pauca, Xylella fastidiosa subsp. sandyi, Xanthomonas campestris. Phytoplasmas Fungi: Verticillium nonalfalfae, Verticillium dahliae, Synchytrium endobioticum Viruses: blackcurrant reversion virus, chrysanthemum stem necrosis virus, gooseberry vein banding associated virus, little cherry virus 1, little cherry virus 2, olive latent virus 1, pepino mosaic virus, rose rosette virus, strawberry mild yellow edge virus, strawberry crinkle virus, strawberry virus 1, strawberry vein banding virus, strawberry mottle virus, strawberry polerovirus 1, tomato brown rugose fruit virus, tomato chlorosis virus, tomato infectious chlorosis virus, tomato mottle mosaic virus, tomato ringspot virus. Source literature: Commission Implementing Regulation (EU) 2020/1191 of 11 August 2020 establishing measures to prevent the introduction into and the spread within the Union of Tomato brown rugose fruit virus (ToBRFV) and repealing Implementing Decision (EU) 2019/1615, as amended. Commission Implementing Regulation (EU) 2020/1201 of 14 August 2020 as regards measures to prevent the introduction into and the spread within the Union of Xylella fastidiosa (Wells et al.), as amended. List of source literature in the relevant work procedures. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"检测生物清单：细菌：Candidatus Arsenophonus phytopathogenicus, Candidatus Liberibacter africanus, Candidatus Liberibacter americanus, Candidatus Liberibacter asiaticus, Candidatus Liberibacter solanacearum, Clavibacter insidiosus, Curtobacterium flaccumfaciens pv. Flaccumfaciens, Erwinia amylovora, Xylella fastidiosa, Xylella fastidiosa subsp. fastidiosa, Xylella fastidiosa subsp. morus, Xylella fastidiosa subsp. multiplex, Xylella fastidiosa subsp. pauca, Xylella fastidiosa subsp. sandyi, Xanthomonas campestris. 植原体 真菌：Verticillium nonalfalfae, Verticillium dahliae, Synchytrium endobioticum 病毒：blackcurrant reversion virus, chrysanthemum stem necrosis virus, gooseberry vein banding associated virus, little cherry virus 1, little cherry virus 2, olive latent virus 1, pepino mosaic virus, rose rosette virus, strawberry mild yellow edge virus, strawberry crinkle virus, strawberry virus 1, strawberry vein banding virus, strawberry mottle virus, strawberry polerovirus 1, tomato brown rugose fruit virus, tomato chlorosis virus, tomato infectious chlorosis virus, tomato mottle mosaic virus, tomato ringspot virus.参考文献：2020年8月11日委员会实施条例（EU）2020/1191，规定防止番茄褐色皱果病毒（ToBRFV）传入欧盟并在欧盟境内传播的措施，并废止实施决定（EU）2019/1615（经修订）。2020年8月14日委员会实施条例（EU）2020/1201，关于防止Xylella fastidiosa (Wells et al.)传入欧盟并在欧盟境内传播的措施（经修订）。参考文献清单见相关工作程序。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Seznam testovaných organismů: Bakterie: Candidatus Arsenophonus phytopathogenicus, Candidatus Liberibacter africanus, Candidatus Liberibacter americanus, Candidatus Liberibacter asiaticus, Candidatus Liberibacter solanacearum, Clavibacter insidiosus, Curtobacterium flaccumfaciens pv. Flaccumfaciens, Erwinia amylovora, Xylella fastidiosa, Xylella fastidiosa subsp. fastidiosa, Xylella fastidiosa subsp. morus, Xylella fastidiosa subsp. multiplex, Xylella fastidiosa subsp. pauca, Xylella fastidiosa subsp. sandyi, Xanthomonas campestris. Fytoplazmy Houby:Verticillium nonalfalfae, Verticillium dahliae, Synchytrium endobioticum Viry: blackcurrant reversion virus, chrysanthemum stem necrosis virus, gooseberry vein banding associated virus, little cherry virus 1, little cherry virus 2, olive latent virus 1, pepino mosaic virus, rose rosette virus, strawberry mild yellow edge virus, strawberry crinkle virus, strawberry virus 1, strawberry vein banding virus, strawberry mottle virus, strawberry polerovirus 1, tomato brown rugose fruit virus, tomato chlorosis virus, tomato infectious chlorosis virus, tomato mottle mosaic virus, tomato ringspot virus. Zdrojová literatura: PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2020/1191 ze dne 11. srpna 2020, kterým se zavádějí opatření proti zavlékání organismu Tomato brown rugose fruit virus (ToBRFV) do Unie a jeho rozšiřování na území Unie a kterým se zrušuje prováděcí rozhodnutí (EU) 2019/1615, ve znění pozdějších předpisů. PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2020/1201 ze dne 14. srpna 2020 o opatřeních proti zavlékání organismu Xylella fastidiosa (Wells et al.) do Unie a proti jeho rozšiřování v rámci Unie, ve znění pozdějších předpisů. Přehled zdrojové literatury v příslušných pracovních postupech. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, materiał siewny, grzyby i organizmy grzybopodobne, bakterie, stawonogi, nicienie, wody do nawadniania i ścieki, gleba, DNA i RNA Wykrywanie i identyfikacja organizmów szkodliwych dla roślin metodą real-time PCR Rostlinný materiál, osivo, houby a houbám podobné organismy, bakterie, členovci, hlístice, závlahové a odpadní vody, půda, DNA a RNA Detekce a identifikace škodlivých organismů rostlin metodou real-time PCR SOP-M-30 Material roslinny, material siewny, grzyby i organizmy grzybopodobne, bakterie, stawonogi, nicienie, wody do nawadniania i scieki, gleba, DNA i RNA Wykrywanie i identyfikacja organizmow szkodliwych dla roslin metoda real-time PCR Rostlinny material, osivo, houby a houbam podobne organismy, bakterie, clenovci, hlistice, zavlahove a odpadni vody, puda, DNA a RNA Detekce a identifikace skodlivych organismu rostlin metodou real-time PCR SOP-M-30","search_en":"Plant material, seed, fungi and fungi-like organisms, bacteria, arthropods, nematodes, irrigation and wastewater, soil, DNA and RNA Detection and identification of plant pests by real-time PCR method SOP-M-30","search_zh":"植物材料、种子、真菌及类真菌生物、细菌、节肢动物、线虫、灌溉水和废水、土壤、DNA和RNA 实时荧光PCR法检测和鉴定植物有害生物 SOP-M-30","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":215,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eb6022367bc59cb65b86cb39","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"16","test_object":"Materiał roślinny, materiał siewny, grzyby i organizmy grzybopodobne, bakterie, stawonogi, nicienie, wody do nawadniania i ścieki, DNA i RNA","test_object_en":"Plant material, seed, fungi and fungi-like organisms, bacteria, arthropods, nematodes, irrigation and wastewater, DNA and RNA","test_object_zh":"植物材料、种子、真菌及类真菌生物、细菌、节肢动物、线虫、灌溉水和废水、DNA和RNA","test_object_cs":"Rostlinný materiál, osivo, houby a houbám podobné organismy, bakterie, členovci, hlístice, závlahové a odpadní vody, DNA a RNA","methodology":"Diagnostyka organizmów szkodliwych dla roślin metodą sekwencjonowania kwasów nukleinowych","methodology_en":"Diagnostics of plant pests by nucleic acid sequencing method","methodology_zh":"核酸测序法诊断植物有害生物","methodology_cs":"Diagnostika škodlivých organismů rostlin metodou sekvenace nukleových kyselin","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Diagnostyka organizmów szkodliwych dla roślin metodą sekwencjonowania kwasów nukleinowych","reference":"SOP-M-31","norm_bases":["SOP-M-31"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Wykaz badanych organizmów: Bakterie: Acidovorax citrulli, Candidatus Liberibacter africanus, Candidatus Liberibacter americanus, Candidatus Liberibacter asiaticus, Candidatus Liberibacter solanacearum, Clavibacter michiganensis subsp. michiganensis, Clavibacter sepedonicus, Dickeya spp., Erwinia amylovora, Pantoea ananatis, Pantoea stewartii subsp. stewartii, Pectobacterium atrosepticum, Pectobacterium carotovorum subsp. carotovorum, Pseudomonas savastanoi pv. glycinea, Pseudomonas syringae pv. actinidiae, Pseudomonas syringae pv. aesculi, Pseudomonas syringae pv. morsprunorum, Ralstonia pseudosolanacearum (filotyp I, III), Ralstonia solanacearum, Ralstonia syzygii, Xanthomonas spp., Xylella fastidiosa, Xylophilus ampelinus. Fitoplazmy Grzyby Chromista: Phytophthora spp., Pythium spp. Wirusy: apple stem grooving virus, apple stem pitting virus, barley yellow mosaic virus, Begomovirus spp., Nepovirus spp. – podgrupa A i B, Orthotospovirus spp., Potyvirus spp., rose rosette virus, Tobamovirus spp., tomato marchitez virus, tomato torrado virus, tomato chocolate spot virus, tomato chocolàte virus, tomato mild mottle virus, wheat streak mosaic virus, prunus necrotic ringspot virus, prune dwarf virus Wiroidy: citrus bark cracking viroid, hop stunt viroid, hop latent viroid, Pospiviroid spp. Zwierzęta: stawonogi, nicienie. Literatura źródłowa: EPPO PM 7/129 DNA barcoding as an identification tool for a number of regulated pests Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"List of organisms tested: Bacteria: Acidovorax citrulli, Candidatus Liberibacter africanus, Candidatus Liberibacter americanus, Candidatus Liberibacter asiaticus, Candidatus Liberibacter solanacearum, Clavibacter michiganensis subsp. michiganensis, Clavibacter sepedonicus, Dickeya spp., Erwinia amylovora, Pantoea ananatis, Pantoea stewartii subsp. stewartii, Pectobacterium atrosepticum, Pectobacterium carotovorum subsp. carotovorum, Pseudomonas savastanoi pv. glycinea, Pseudomonas syringae pv. actinidiae, Pseudomonas syringae pv. aesculi, Pseudomonas syringae pv. morsprunorum, Ralstonia pseudosolanacearum (phylotypes I, III), Ralstonia solanacearum, Ralstonia syzygii, Xanthomonas spp., Xylella fastidiosa, Xylophilus ampelinus. Phytoplasmas Fungi Chromista: Phytophthora spp., Pythium spp. Viruses: apple stem grooving virus, apple stem pitting virus, barley yellow mosaic virus, Begomovirus spp., Nepovirus spp. – subgroup A and B, Orthotospovirus spp., Potyvirus spp., rose rosette virus, Tobamovirus spp., tomato marchitez virus, tomato torrado virus, tomato chocolate spot virus, tomato chocolàte virus, tomato mild mottle virus, wheat streak mosaic virus, prunus necrotic ringspot virus, prune dwarf virus Viroids: citrus bark cracking viroid, hop stunt viroid, hop latent viroid, Pospiviroid spp. Animalia: arthropods, nematodes. Source literature: EPPO PM 7/129 DNA barcoding as an identification tool for a number of regulated pests Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"检测生物清单：细菌：Acidovorax citrulli, Candidatus Liberibacter africanus, Candidatus Liberibacter americanus, Candidatus Liberibacter asiaticus, Candidatus Liberibacter solanacearum, Clavibacter michiganensis subsp. michiganensis, Clavibacter sepedonicus, Dickeya spp., Erwinia amylovora, Pantoea ananatis, Pantoea stewartii subsp. stewartii, Pectobacterium atrosepticum, Pectobacterium carotovorum subsp. carotovorum, Pseudomonas savastanoi pv. glycinea, Pseudomonas syringae pv. actinidiae, Pseudomonas syringae pv. aesculi, Pseudomonas syringae pv. morsprunorum, Ralstonia pseudosolanacearum（系统型I、III）, Ralstonia solanacearum, Ralstonia syzygii, Xanthomonas spp., Xylella fastidiosa, Xylophilus ampelinus. 植原体 真菌 色藻界：Phytophthora spp., Pythium spp. 病毒：apple stem grooving virus, apple stem pitting virus, barley yellow mosaic virus, Begomovirus spp., Nepovirus spp.——A和B亚组, Orthotospovirus spp., Potyvirus spp., rose rosette virus, Tobamovirus spp., tomato marchitez virus, tomato torrado virus, tomato chocolate spot virus, tomato chocolàte virus, tomato mild mottle virus, wheat streak mosaic virus, prunus necrotic ringspot virus, prune dwarf virus 类病毒：citrus bark cracking viroid, hop stunt viroid, hop latent viroid, Pospiviroid spp. 动物：节肢动物、线虫。参考文献：EPPO PM 7/129 DNA barcoding as an identification tool for a number of regulated pests相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Seznam testovaných organismů: Bakterie: Acidovorax citrulli, Candidatus Liberibacter africanus, Candidatus Liberibacter americanus, Candidatus Liberibacter asiaticus, Candidatus Liberibacter solanacearum, Clavibacter michiganensis subsp. michiganensis, Clavibacter sepedonicus, Dickeya spp., Erwinia amylovora, Pantoea ananatis, Pantoea stewartii subsp. stewartii, Pectobacterium atrosepticum, Pectobacterium carotovorum subsp. carotovorum, Pseudomonas savastanoi pv. glycinea, Pseudomonas syringae pv. actinidiae, Pseudomonas syringae pv. aesculi, Pseudomonas syringae pv. morsprunorum, Ralstonia pseudosolanacearum (fylotyp I, III), Ralstonia solanacearum, Ralstonia syzygii, Xanthomonas spp., Xylella fastidiosa, Xylophilus ampelinus. Fytoplazmy Houby Chromisté: Phytophthora spp., Pythium spp. Viry: apple stem grooving virus, apple stem pitting virus, barley yellow mosaic virus, Begomovirus spp., Nepovirus spp. – podskupina A a B, Orthotospovirus spp., Potyvirus spp., rose rosette virus, Tobamovirus spp., tomato marchitez virus, tomato torrado virus, tomato chocolate spot virus, tomato chocolàte virus, tomato mild mottle virus, wheat streak mosaic virus, prunus necrotic ringspot virus, prune dwarf virus Viroidy: citrus bark cracking viroid, hop stunt viroid, hop latent viroid, Pospiviroid spp. Živočichové: členovci, hlístice. Zdrojová literatura: EPPO PM 7/129 DNA barcoding as an identification tool for a number of regulated pests Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, materiał siewny, grzyby i organizmy grzybopodobne, bakterie, stawonogi, nicienie, wody do nawadniania i ścieki, DNA i RNA Diagnostyka organizmów szkodliwych dla roślin metodą sekwencjonowania kwasów nukleinowych Rostlinný materiál, osivo, houby a houbám podobné organismy, bakterie, členovci, hlístice, závlahové a odpadní vody, DNA a RNA Diagnostika škodlivých organismů rostlin metodou sekvenace nukleových kyselin SOP-M-31 Material roslinny, material siewny, grzyby i organizmy grzybopodobne, bakterie, stawonogi, nicienie, wody do nawadniania i scieki, DNA i RNA Diagnostyka organizmow szkodliwych dla roslin metoda sekwencjonowania kwasow nukleinowych Rostlinny material, osivo, houby a houbam podobne organismy, bakterie, clenovci, hlistice, zavlahove a odpadni vody, DNA a RNA Diagnostika skodlivych organismu rostlin metodou sekvenace nukleovych kyselin SOP-M-31","search_en":"Plant material, seed, fungi and fungi-like organisms, bacteria, arthropods, nematodes, irrigation and wastewater, DNA and RNA Diagnostics of plant pests by nucleic acid sequencing method SOP-M-31","search_zh":"植物材料、种子、真菌及类真菌生物、细菌、节肢动物、线虫、灌溉水和废水、DNA和RNA 核酸测序法诊断植物有害生物 SOP-M-31","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":216,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"652472bfe940fa7ccf2d9386","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"17","test_object":"Materiał roślinny, materiał siewny, grzyby i organizmy grzybopodobne, bakterie, stawonogi, nicienie, wody do nawadniania i ścieki, DNA i RNA","test_object_en":"Plant material, seed, fungi and fungi-like organisms, bacteria, arthropods, nematodes, irrigation and wastewater, DNA and RNA","test_object_zh":"植物材料、种子、真菌及类真菌生物、细菌、节肢动物、线虫、灌溉水和废水、DNA和RNA","test_object_cs":"Rostlinný materiál, osivo, houby a houbám podobné organismy, bakterie, členovci, hlístice, závlahové a odpadní vody, DNA a RNA","methodology":"Wykrywanie i identyfikacja organizmów szkodliwych dla roślin metodą konwencjonalnej PCR","methodology_en":"Detection and identification of plant pests by conventional PCR method","methodology_zh":"常规PCR法检测和鉴定植物有害生物","methodology_cs":"Detekce a identifikace škodlivých organismů rostlin metodou konvenční PCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja organizmów szkodliwych dla roślin metodą konwencjonalnej PCR","reference":"SOP-M-33","norm_bases":["SOP-M-33"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":"Wykaz badanych organizmów: Bakterie: Acidovorax citrulli, Candidatus Liberibacter africanus, Candidatus Liberibacter americanus, Candidatus Liberibacter asiaticus, Candidatus Liberibacter solanacearum, Clavibacter michiganensis subsp. michiganensis, Clavibacter sepedonicus, Dickeya spp., Erwinia amylovora, Pantoea ananatis, Pantoea stewartii subsp. stewartii, Pectobacterium atrosepticum, Pectobacterium carotovorum subsp. carotovorum, Pseudomonas savastanoi pv. glycinea, Pseudomonas syringae pv. actinidiae, Pseudomonas syringae pv. aesculi, Pseudomonas syringae pv. morsprunorum, Ralstonia pseudosolanacearum (filotyp I, III), Ralstonia solanacearum, Ralstonia syzygii, Xanthomonas spp., Xylella fastidiosa, Xylophilus ampelinus. Fitoplazmy Grzyby Chromista: Phytophthora spp., Pythium spp. Wirusy: apple stem grooving virus, apple stem pitting virus, barley yellow mosaic virus, Begomovirus spp., Nepovirus spp. – podgrupa A i B, Orthotospovirus spp., Potyvirus spp., rose rosette virus, Tobamovirus spp., tomato marchitez virus, tomato torrado virus, tomato chocolate spot virus, tomato chocolàte virus, tomato mild mottle virus, wheat streak mosaic virus, prunus necrotic ringspot virus, prune dwarf virus Wiroidy: citrus bark cracking viroid, hop stunt viroid, hop latent viroid, Pospiviroid spp. Zwierzęta: stawonogi, nicienie. Literatura źródłowa: Wykaz literatury źródłowej we właściwych procedurach roboczych. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"List of organisms tested: Bacteria: Acidovorax citrulli, Candidatus Liberibacter africanus, Candidatus Liberibacter americanus, Candidatus Liberibacter asiaticus, Candidatus Liberibacter solanacearum, Clavibacter michiganensis subsp. michiganensis, Clavibacter sepedonicus, Dickeya spp., Erwinia amylovora, Pantoea ananatis, Pantoea stewartii subsp. stewartii, Pectobacterium atrosepticum, Pectobacterium carotovorum subsp. carotovorum, Pseudomonas savastanoi pv. glycinea, Pseudomonas syringae pv. actinidiae, Pseudomonas syringae pv. aesculi, Pseudomonas syringae pv. morsprunorum, Ralstonia pseudosolanacearum (phylotypes I, III), Ralstonia solanacearum, Ralstonia syzygii, Xanthomonas spp., Xylella fastidiosa, Xylophilus ampelinus. Phytoplasmas Fungi Chromista: Phytophthora spp., Pythium spp. Viruses: apple stem grooving virus, apple stem pitting virus, barley yellow mosaic virus, Begomovirus spp., Nepovirus spp. – subgroup A and B, Orthotospovirus spp., Potyvirus spp., rose rosette virus, Tobamovirus spp., tomato marchitez virus, tomato torrado virus, tomato chocolate spot virus, tomato chocolàte virus, tomato mild mottle virus, wheat streak mosaic virus, prunus necrotic ringspot virus, prune dwarf virus Viroids: citrus bark cracking viroid, hop stunt viroid, hop latent viroid, Pospiviroid spp. Animalia: arthropods, nematodes. Source literature: List of source literature in the relevant work procedures. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"检测生物清单：细菌：Acidovorax citrulli, Candidatus Liberibacter africanus, Candidatus Liberibacter americanus, Candidatus Liberibacter asiaticus, Candidatus Liberibacter solanacearum, Clavibacter michiganensis subsp. michiganensis, Clavibacter sepedonicus, Dickeya spp., Erwinia amylovora, Pantoea ananatis, Pantoea stewartii subsp. stewartii, Pectobacterium atrosepticum, Pectobacterium carotovorum subsp. carotovorum, Pseudomonas savastanoi pv. glycinea, Pseudomonas syringae pv. actinidiae, Pseudomonas syringae pv. aesculi, Pseudomonas syringae pv. morsprunorum, Ralstonia pseudosolanacearum（系统型I、III）, Ralstonia solanacearum, Ralstonia syzygii, Xanthomonas spp., Xylella fastidiosa, Xylophilus ampelinus. 植原体 真菌 色藻界：Phytophthora spp., Pythium spp. 病毒：apple stem grooving virus, apple stem pitting virus, barley yellow mosaic virus, Begomovirus spp., Nepovirus spp.——A和B亚组, Orthotospovirus spp., Potyvirus spp., rose rosette virus, Tobamovirus spp., tomato marchitez virus, tomato torrado virus, tomato chocolate spot virus, tomato chocolàte virus, tomato mild mottle virus, wheat streak mosaic virus, prunus necrotic ringspot virus, prune dwarf virus 类病毒：citrus bark cracking viroid, hop stunt viroid, hop latent viroid, Pospiviroid spp. 动物：节肢动物、线虫。参考文献：参考文献清单见相关工作程序。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Seznam testovaných organismů: Bakterie: Acidovorax citrulli, Candidatus Liberibacter africanus, Candidatus Liberibacter americanus, Candidatus Liberibacter asiaticus, Candidatus Liberibacter solanacearum, Clavibacter michiganensis subsp. michiganensis, Clavibacter sepedonicus, Dickeya spp., Erwinia amylovora, Pantoea ananatis, Pantoea stewartii subsp. stewartii, Pectobacterium atrosepticum, Pectobacterium carotovorum subsp. carotovorum, Pseudomonas savastanoi pv. glycinea, Pseudomonas syringae pv. actinidiae, Pseudomonas syringae pv. aesculi, Pseudomonas syringae pv. morsprunorum, Ralstonia pseudosolanacearum (fylotyp I, III), Ralstonia solanacearum, Ralstonia syzygii, Xanthomonas spp., Xylella fastidiosa, Xylophilus ampelinus. Fytoplazmy Houby Chromisté: Phytophthora spp., Pythium spp. Viry: apple stem grooving virus, apple stem pitting virus, barley yellow mosaic virus, Begomovirus spp., Nepovirus spp. – podskupina A a B, Orthotospovirus spp., Potyvirus spp., rose rosette virus, Tobamovirus spp., tomato marchitez virus, tomato torrado virus, tomato chocolate spot virus, tomato chocolàte virus, tomato mild mottle virus, wheat streak mosaic virus, prunus necrotic ringspot virus, prune dwarf virus Viroidy: citrus bark cracking viroid, hop stunt viroid, hop latent viroid, Pospiviroid spp. Živočichové: členovci, hlístice. Zdrojová literatura: Přehled zdrojové literatury v příslušných pracovních postupech. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, materiał siewny, grzyby i organizmy grzybopodobne, bakterie, stawonogi, nicienie, wody do nawadniania i ścieki, DNA i RNA Wykrywanie i identyfikacja organizmów szkodliwych dla roślin metodą konwencjonalnej PCR Rostlinný materiál, osivo, houby a houbám podobné organismy, bakterie, členovci, hlístice, závlahové a odpadní vody, DNA a RNA Detekce a identifikace škodlivých organismů rostlin metodou konvenční PCR SOP-M-33 Material roslinny, material siewny, grzyby i organizmy grzybopodobne, bakterie, stawonogi, nicienie, wody do nawadniania i scieki, DNA i RNA Wykrywanie i identyfikacja organizmow szkodliwych dla roslin metoda konwencjonalnej PCR Rostlinny material, osivo, houby a houbam podobne organismy, bakterie, clenovci, hlistice, zavlahove a odpadni vody, DNA a RNA Detekce a identifikace skodlivych organismu rostlin metodou konvencni PCR SOP-M-33","search_en":"Plant material, seed, fungi and fungi-like organisms, bacteria, arthropods, nematodes, irrigation and wastewater, DNA and RNA Detection and identification of plant pests by conventional PCR method SOP-M-33","search_zh":"植物材料、种子、真菌及类真菌生物、细菌、节肢动物、线虫、灌溉水和废水、DNA和RNA 常规PCR法检测和鉴定植物有害生物 SOP-M-33","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":217,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6e2dc427e51e1ebf39955d09","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"18","test_object":"Gleba, podłoża, materiał roślinny","test_object_en":"Soil, substrates, plant material","test_object_zh":"土壤、基质、植物材料","test_object_cs":"Půda, substráty, rostlinný materiál","methodology":"Wykrywanie i identyfikacja przetrwalnikowych zoosporangiów sprawcy raka ziemniaka Synchytrium endobioticum metodą mikroskopii świetlnej","methodology_en":"Detection and identification of permanent zoosporangia of Synchytrium endobioticum, the causal agent of potato wart disease, by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定马铃薯癌肿病病原菌Synchytrium endobioticum的休眠孢子囊","methodology_cs":"Detekce a identifikace trvalých zoosporangií původce rakoviny bramboru Synchytrium endobioticum metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja przetrwalnikowych zoosporangiów sprawcy raka ziemniaka Synchytrium endobioticum metodą mikroskopii świetlnej","reference":"SOP-M-69, mimo kap. 7.1.4","norm_bases":["SOP-M-69"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Literatura źródłowa: Karling J.S. (1964): Synchytrium. Academic press, 470 p., EPPO PM 7/28 Synchytrium endobioticum. Rozporządzenie wykonawcze Komisji (UE) 2022/1195 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Synchytrium endobioticum (Schilbersky) Percival.","note_en":"Source literature: Karling J.S. (1964): Synchytrium. Academic press, 470 p., EPPO PM 7/28 Synchytrium endobioticum. Commission Implementing Regulation (EU) 2022/1195 of 11 July 2022 establishing measures to eradicate and prevent the spread of Synchytrium endobioticum (Schilbersky) Percival.","note_zh":"参考文献：Karling J.S. (1964): Synchytrium. Academic press, 470 p., EPPO PM 7/28 Synchytrium endobioticum.2022年7月11日委员会实施条例（EU）2022/1195，规定根除和防止Synchytrium endobioticum (Schilbersky) Percival传播的措施。","note_cs":"Zdrojová literatura: Karling J.S. (1964): Synchytrium. Academic press, 470 p., EPPO PM 7/28 Synchytrium endobioticum. PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1195 ze dne 11.července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismu Synchytrium endobioticum (Schilbersky) Percival.","search_text":"Gleba, podłoża, materiał roślinny Wykrywanie i identyfikacja przetrwalnikowych zoosporangiów sprawcy raka ziemniaka Synchytrium endobioticum metodą mikroskopii świetlnej Půda, substráty, rostlinný materiál Detekce a identifikace trvalých zoosporangií původce rakoviny bramboru Synchytrium endobioticum metodou světelné mikroskopie SOP-M-69, mimo kap. 7.1.4 Gleba, podloza, material roslinny Wykrywanie i identyfikacja przetrwalnikowych zoosporangiow sprawcy raka ziemniaka Synchytrium endobioticum metoda mikroskopii swietlnej Puda, substraty, rostlinny material Detekce a identifikace trvalych zoosporangii puvodce rakoviny bramboru Synchytrium endobioticum metodou svetelne mikroskopie SOP-M-69, mimo kap. 7.1.4","search_en":"Soil, substrates, plant material Detection and identification of permanent zoosporangia of Synchytrium endobioticum, the causal agent of potato wart disease, by light microscopy method SOP-M-69, mimo kap. 7.1.4","search_zh":"土壤、基质、植物材料 光学显微镜法检测和鉴定马铃薯癌肿病病原菌Synchytrium endobioticum的休眠孢子囊 SOP-M-69, mimo kap. 7.1.4","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":218,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"02df402b6474389b873081d6","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"19","test_object":"Gleba, podłoża, materiał roślinny","test_object_en":"Soil, substrates, plant material","test_object_zh":"土壤、基质、植物材料","test_object_cs":"Půda, substráty, rostlinný materiál","methodology":"Wykrywanie i identyfikacja przetrwalnikowych zoosporangiów sprawcy raka ziemniaka Synchytrium endobioticum testem biologicznym","methodology_en":"Detection and identification of permanent zoosporangia of Synchytrium endobioticum, the causal agent of potato wart disease, by biological test","methodology_zh":"生物测定法检测和鉴定马铃薯癌肿病病原菌Synchytrium endobioticum的休眠孢子囊","methodology_cs":"Detekce a identifikace trvalých zoosporangií původce rakoviny bramboru Synchytrium endobioticum biologickým testem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja przetrwalnikowych zoosporangiów sprawcy raka ziemniaka Synchytrium endobioticum testem biologicznym","reference":"SOP-M-69, mimo kap. 7.1.3","norm_bases":["SOP-M-69"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Literatura źródłowa: Karling J.S. (1964): Synchytrium. Academic press, 470 p., EPPO PM 7/28 Synchytrium endobioticum. Rozporządzenie wykonawcze Komisji (UE) 2022/1195 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Synchytrium endobioticum (Schilbersky) Percival.","note_en":"Source literature: Karling J.S. (1964): Synchytrium. Academic press, 470 p., EPPO PM 7/28 Synchytrium endobioticum. Commission Implementing Regulation (EU) 2022/1195 of 11 July 2022 establishing measures to eradicate and prevent the spread of Synchytrium endobioticum (Schilbersky) Percival.","note_zh":"参考文献：Karling J.S. (1964): Synchytrium. Academic press, 470 p., EPPO PM 7/28 Synchytrium endobioticum.2022年7月11日委员会实施条例（EU）2022/1195，规定根除和防止Synchytrium endobioticum (Schilbersky) Percival传播的措施。","note_cs":"Zdrojová literatura: Karling J.S. (1964): Synchytrium. Academic press, 470 p., EPPO PM 7/28 Synchytrium endobioticum. PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1195 ze dne 11.července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismu Synchytrium endobioticum (Schilbersky) Percival.","search_text":"Gleba, podłoża, materiał roślinny Wykrywanie i identyfikacja przetrwalnikowych zoosporangiów sprawcy raka ziemniaka Synchytrium endobioticum testem biologicznym Půda, substráty, rostlinný materiál Detekce a identifikace trvalých zoosporangií původce rakoviny bramboru Synchytrium endobioticum biologickým testem SOP-M-69, mimo kap. 7.1.3 Gleba, podloza, material roslinny Wykrywanie i identyfikacja przetrwalnikowych zoosporangiow sprawcy raka ziemniaka Synchytrium endobioticum testem biologicznym Puda, substraty, rostlinny material Detekce a identifikace trvalych zoosporangii puvodce rakoviny bramboru Synchytrium endobioticum biologickym testem SOP-M-69, mimo kap. 7.1.3","search_en":"Soil, substrates, plant material Detection and identification of permanent zoosporangia of Synchytrium endobioticum, the causal agent of potato wart disease, by biological test SOP-M-69, mimo kap. 7.1.3","search_zh":"土壤、基质、植物材料 生物测定法检测和鉴定马铃薯癌肿病病原菌Synchytrium endobioticum的休眠孢子囊 SOP-M-69, mimo kap. 7.1.3","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":219,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"70e2c5f8e454f5d918de431f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"20","test_object":"Materiał roślinny, drewno, materiał siewny, podłoża, owady, roztocze","test_object_en":"Plant material, wood, seed, substrates, insects, mites","test_object_zh":"植物材料、木材、种子、基质、昆虫、螨类","test_object_cs":"Rostlinný materiál, dřevo, osivo, substráty, hmyz, roztoči","methodology":"Wykrywanie i identyfikacja owadów fitofagicznych, saprofagicznych i drapieżnych oraz roztoczy metodą mikroskopii świetlnej","methodology_en":"Detection and identification of phytophagous, saprophagous and predatory insects and mites by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定植食性、腐食性和捕食性昆虫及螨类","methodology_cs":"Detekce a identifikace fytofágního, saprofágního a dravého hmyzu a roztočů metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja owadów fitofagicznych, saprofagicznych i drapieżnych oraz roztoczy metodą mikroskopii świetlnej","reference":"SOP-M-40","norm_bases":["SOP-M-40"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: LELLÁKOVÁ, F. Zoologická technika. 1. vyd. Praha: Universita Karlova, 1985. 122 s. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: LELLÁKOVÁ, F. Zoologická technika. 1. vyd. Praha: Universita Karlova, 1985. 122 s. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：LELLÁKOVÁ, F. Zoologická technika. 1. vyd. Praha: Universita Karlova, 1985. 122 s.相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: LELLÁKOVÁ, F. Zoologická technika. 1. vyd. Praha: Universita Karlova, 1985. 122 s. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, drewno, materiał siewny, podłoża, owady, roztocze Wykrywanie i identyfikacja owadów fitofagicznych, saprofagicznych i drapieżnych oraz roztoczy metodą mikroskopii świetlnej Rostlinný materiál, dřevo, osivo, substráty, hmyz, roztoči Detekce a identifikace fytofágního, saprofágního a dravého hmyzu a roztočů metodou světelné mikroskopie SOP-M-40 Material roslinny, drewno, material siewny, podloza, owady, roztocze Wykrywanie i identyfikacja owadow fitofagicznych, saprofagicznych i drapieznych oraz roztoczy metoda mikroskopii swietlnej Rostlinny material, drevo, osivo, substraty, hmyz, roztoci Detekce a identifikace fytofagniho, saprofagniho a draveho hmyzu a roztocu metodou svetelne mikroskopie SOP-M-40","search_en":"Plant material, wood, seed, substrates, insects, mites Detection and identification of phytophagous, saprophagous and predatory insects and mites by light microscopy method SOP-M-40","search_zh":"植物材料、木材、种子、基质、昆虫、螨类 光学显微镜法检测和鉴定植食性、腐食性和捕食性昆虫及螨类 SOP-M-40","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":220,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5e5dbc52eca24f415b827c59","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"21","test_object":"Zboża, rośliny oleiste, rośliny strączkowe, materiał siewny, herbaty, kakao, czekolada, suszone owoce, suszone zioła, suszone przyprawy, makarony, orzechy, bawełna, włókno lniane, wełna owcza","test_object_en":"Cereals, oilseeds, legumes, seed, tea, cocoa, chocolate, dried fruit, dried herbs, dried spices, pasta, nuts, cotton, flax fibre, sheep wool","test_object_zh":"谷物、油料作物、豆类、种子、茶叶、可可、巧克力、干果、干草药、干香料、面食、坚果、棉花、亚麻纤维、羊毛","test_object_cs":"Obilniny, olejniny, luskoviny, osiva, čaje, kakao, čokoláda, sušené ovoce, sušené byliny, sušené koření, těstoviny, ořechy, bavlna, lněné vlákno, ovčí vlna","methodology":"Wykrywanie i identyfikacja szkodników magazynowych metodą mikroskopii świetlnej","methodology_en":"Detection and identification of storage pests by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定储藏害虫","methodology_cs":"Detekce a identifikace skladištních škůdců metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja szkodników magazynowych metodą mikroskopii świetlnej","reference":"SOP-M-50","norm_bases":["SOP-M-50"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Ołomuniec","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Olomouc","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥洛穆茨植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Olomouc","lab_address":"Šlechtitelů 773/23, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: Ustawa nr 219/2003 Sb. o wprowadzaniu do obrotu materiału siewnego i sadzeniaków roślin uprawnych i o zmianie niektórych ustaw. Rozporządzenie nr 129/2012 Sb. o szczegółach wprowadzania do obrotu materiału siewnego i sadzeniaków roślin uprawnych, z późniejszymi zmianami. Rozporządzenie nr 61/2011 Sb. określające wymagania dotyczące pobierania próbek, procedury i metody badania materiału siewnego i sadzeniaków, z późniejszymi zmianami. Bartoš, J., Verner, P.H., Pulpán, J., Boj proti skladištním škůdcům, Státní zemědělské nakladatelství Praha, 1961. Stejskal, V., Ph.D. a kol., Detekce kontaminace skladovaných obilovin a cereálních produktů škůdci pomocí fyzikálně-chemických technik, metodika pro útvary státní správy, Výzkumný ústav rostlinné výroby, v.v.i., Praha, 2007. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: Act No. 219/2003 Sb., on the marketing of seeds and planting materials of cultivated plants and on amendments to certain acts. Decree No. 129/2012 Sb., on details of the marketing of seeds and planting materials of cultivated plants, as amended. Decree No. 61/2011 Sb., laying down requirements for sampling, procedures and methods for testing seeds and planting materials, as amended. Bartoš, J., Verner, P.H., Pulpán, J., Boj proti skladištním škůdcům, Státní zemědělské nakladatelství Praha, 1961. Stejskal, V., Ph.D. a kol., Detekce kontaminace skladovaných obilovin a cereálních produktů škůdci pomocí fyzikálně-chemických technik, metodika pro útvary státní správy, Výzkumný ústav rostlinné výroby, v.v.i., Praha, 2007. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：第219/2003 Sb.号法律（关于栽培植物种子和种苗的上市及若干法律的修订）。第129/2012 Sb.号法令（关于栽培植物种子和种苗上市的细则，经修订）。第61/2011 Sb.号法令（规定种子和种苗的抽样要求、检测程序和方法，经修订）。Bartoš, J., Verner, P.H., Pulpán, J., Boj proti skladištním škůdcům, Státní zemědělské nakladatelství Praha, 1961.Stejskal, V., Ph.D. a kol., Detekce kontaminace skladovaných obilovin a cereálních produktů škůdci pomocí fyzikálně-chemických technik, metodika pro útvary státní správy, Výzkumný ústav rostlinné výroby, v.v.i., Praha, 2007.相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: Zákon č. 219/2003 Sb., o uvádění do oběhu osiva a sadby pěstovaných rostlin a o změně některých zákonů. Vyhláška č. 129/2012 Sb., o podrobnostech uvádění osiva a sadby pěstovaných rostlin do oběhu, ve znění pozdějších předpisů. Vyhláška č. 61/2011 Sb., kterou se stanoví požadavky na odběr vzorků, postupy a metody zkoušení osiva a sadby, ve znění pozdějších předpisů. Bartoš, J., Verner, P.H., Pulpán, J., Boj proti skladištním škůdcům, Státní zemědělské nakladatelství Praha, 1961. Stejskal, V., Ph.D. a kol., Detekce kontaminace skladovaných obilovin a cereálních produktů škůdci pomocí fyzikálně-chemických technik, metodika pro útvary státní správy, Výzkumný ústav rostlinné výroby, v.v.i., Praha, 2007. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Zboża, rośliny oleiste, rośliny strączkowe, materiał siewny, herbaty, kakao, czekolada, suszone owoce, suszone zioła, suszone przyprawy, makarony, orzechy, bawełna, włókno lniane, wełna owcza Wykrywanie i identyfikacja szkodników magazynowych metodą mikroskopii świetlnej Obilniny, olejniny, luskoviny, osiva, čaje, kakao, čokoláda, sušené ovoce, sušené byliny, sušené koření, těstoviny, ořechy, bavlna, lněné vlákno, ovčí vlna Detekce a identifikace skladištních škůdců metodou světelné mikroskopie SOP-M-50 Zboza, rosliny oleiste, rosliny straczkowe, material siewny, herbaty, kakao, czekolada, suszone owoce, suszone ziola, suszone przyprawy, makarony, orzechy, bawelna, wlokno lniane, welna owcza Wykrywanie i identyfikacja szkodnikow magazynowych metoda mikroskopii swietlnej Obilniny, olejniny, luskoviny, osiva, caje, kakao, cokolada, susene ovoce, susene byliny, susene koreni, testoviny, orechy, bavlna, lnene vlakno, ovci vlna Detekce a identifikace skladistnich skudcu metodou svetelne mikroskopie SOP-M-50","search_en":"Cereals, oilseeds, legumes, seed, tea, cocoa, chocolate, dried fruit, dried herbs, dried spices, pasta, nuts, cotton, flax fibre, sheep wool Detection and identification of storage pests by light microscopy method SOP-M-50","search_zh":"谷物、油料作物、豆类、种子、茶叶、可可、巧克力、干果、干草药、干香料、面食、坚果、棉花、亚麻纤维、羊毛 光学显微镜法检测和鉴定储藏害虫 SOP-M-50","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":221,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"753e44eaf2723fb5493cfdeb","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"1","test_object":"Środki ochrony roślin – formulacje ciekłe","test_object_en":"Plant protection products – liquid formulations","test_object_zh":"植物保护产品——液体制剂","test_object_cs":"Přípravky na ochranu rostlin – kapalné formulace","methodology":"Oznaczanie gęstości metodą tensjometryczną","methodology_en":"Determination of density by tensiometric method","methodology_zh":"张力计法测定密度","methodology_cs":"Stanovení hustoty tenziometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości metodą tensjometryczną","reference":"SOP-FCH-07-01 (CIPAC MT 3.1; CIPAC MT 3.3.1)","norm_bases":["SOP-FCH-07-01","CIPAC MT 3.1","CIPAC MT 3.3.1"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin – formulacje ciekłe Oznaczanie gęstości metodą tensjometryczną Přípravky na ochranu rostlin – kapalné formulace Stanovení hustoty tenziometricky SOP-FCH-07-01 (CIPAC MT 3.1; CIPAC MT 3.3.1) Srodki ochrony roslin – formulacje ciekle Oznaczanie gestosci metoda tensjometryczna Pripravky na ochranu rostlin – kapalne formulace Stanoveni hustoty tenziometricky SOP-FCH-07-01 (CIPAC MT 3.1; CIPAC MT 3.3.1)","search_en":"Plant protection products – liquid formulations Determination of density by tensiometric method SOP-FCH-07-01 (CIPAC MT 3.1; CIPAC MT 3.3.1)","search_zh":"植物保护产品——液体制剂 张力计法测定密度 SOP-FCH-07-01 (CIPAC MT 3.1; CIPAC MT 3.3.1)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":222,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"90b4ea3754e652a4bdd68872","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"2","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometric method","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"SOP-FCH-07-02 (CIPAC MT 75.3)","norm_bases":["SOP-FCH-07-02","CIPAC MT 75.3"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin Oznaczanie pH metodą potencjometryczną Přípravky na ochranu rostlin Stanovení pH potenciometricky SOP-FCH-07-02 (CIPAC MT 75.3) Srodki ochrony roslin Oznaczanie pH metoda potencjometryczna Pripravky na ochranu rostlin Stanoveni pH potenciometricky SOP-FCH-07-02 (CIPAC MT 75.3)","search_en":"Plant protection products Determination of pH by potentiometric method SOP-FCH-07-02 (CIPAC MT 75.3)","search_zh":"植物保护产品 电位法测定pH SOP-FCH-07-02 (CIPAC MT 75.3)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":223,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8f2e10152411a5c6868ca26a","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"3","test_object":"Środki ochrony roślin stosowane jako dyspersja w wodzie","test_object_en":"Plant protection products applicable as dispersion in water","test_object_zh":"以水分散体形式施用的植物保护产品","test_object_cs":"Přípravky na ochranu rostlin aplikovatelné jako disperze ve vodě","methodology":"Oznaczanie pozostałości na sicie metodą wagową","methodology_en":"Determination of residue on sieve by gravimetric method","methodology_zh":"重量法测定筛余物","methodology_cs":"Stanovení zbytku na sítě gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pozostałości na sicie metodą wagową","reference":"SOP-FCH-07-07 (CIPAC MT 185)","norm_bases":["SOP-FCH-07-07","CIPAC MT 185"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin stosowane jako dyspersja w wodzie Oznaczanie pozostałości na sicie metodą wagową Přípravky na ochranu rostlin aplikovatelné jako disperze ve vodě Stanovení zbytku na sítě gravimetricky SOP-FCH-07-07 (CIPAC MT 185) Srodki ochrony roslin stosowane jako dyspersja w wodzie Oznaczanie pozostalosci na sicie metoda wagowa Pripravky na ochranu rostlin aplikovatelne jako disperze ve vode Stanoveni zbytku na site gravimetricky SOP-FCH-07-07 (CIPAC MT 185)","search_en":"Plant protection products applicable as dispersion in water Determination of residue on sieve by gravimetric method SOP-FCH-07-07 (CIPAC MT 185)","search_zh":"以水分散体形式施用的植物保护产品 重量法测定筛余物 SOP-FCH-07-07 (CIPAC MT 185)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":224,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d340c00b7e09044c2bb9fd6a","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"4","test_object":"Środki ochrony roślin – proszki i granulaty zwilżalne","test_object_en":"Plant protection products – wettable powders and granulates","test_object_zh":"植物保护产品——可湿性粉剂和颗粒剂","test_object_cs":"Přípravky na ochranu rostlin – smáčitelné prášky a granuláty","methodology":"Oznaczanie zwilżalności metodą wizualną","methodology_en":"Determination of wettability by visual method","methodology_zh":"目视法测定润湿性","methodology_cs":"Stanovení smáčitelnosti vizuálně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zwilżalności metodą wizualną","reference":"SOP-FCH-07-05 (CIPAC MT 53.3.1)","norm_bases":["SOP-FCH-07-05","CIPAC MT 53.3.1"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin – proszki i granulaty zwilżalne Oznaczanie zwilżalności metodą wizualną Přípravky na ochranu rostlin – smáčitelné prášky a granuláty Stanovení smáčitelnosti vizuálně SOP-FCH-07-05 (CIPAC MT 53.3.1) Srodki ochrony roslin – proszki i granulaty zwilzalne Oznaczanie zwilzalnosci metoda wizualna Pripravky na ochranu rostlin – smacitelne prasky a granulaty Stanoveni smacitelnosti vizualne SOP-FCH-07-05 (CIPAC MT 53.3.1)","search_en":"Plant protection products – wettable powders and granulates Determination of wettability by visual method SOP-FCH-07-05 (CIPAC MT 53.3.1)","search_zh":"植物保护产品——可湿性粉剂和颗粒剂 目视法测定润湿性 SOP-FCH-07-05 (CIPAC MT 53.3.1)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":225,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9b5284f489997a3dcc765a6f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"5","test_object":"Środki ochrony roślin, których substancje czynne lub składniki formulacji nie reagują z użytym odczynnikiem","test_object_en":"Plant protection products whose active substances or formulants do not react with the reagent used","test_object_zh":"其活性成分或助剂不与所用试剂反应的植物保护产品","test_object_cs":"Přípravky na ochranu rostlin, jejichž účinné látky nebo formulační přísady nereagují s použitým typem činidla","methodology":"Oznaczanie wody metodą Karla Fischera","methodology_en":"Determination of water pursuant to Karl Fischer","methodology_zh":"卡尔·费休法测定水分","methodology_cs":"Stanovení vody metodou podle Karl Fischera","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wody metodą Karla Fischera","reference":"SOP-CH-07-01 (CIPAC MT 30.5)","norm_bases":["SOP-CH-07-01","CIPAC MT 30.5"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin, których substancje czynne lub składniki formulacji nie reagują z użytym odczynnikiem Oznaczanie wody metodą Karla Fischera Přípravky na ochranu rostlin, jejichž účinné látky nebo formulační přísady nereagují s použitým typem činidla Stanovení vody metodou podle Karl Fischera SOP-CH-07-01 (CIPAC MT 30.5) Srodki ochrony roslin, ktorych substancje czynne lub skladniki formulacji nie reaguja z uzytym odczynnikiem Oznaczanie wody metoda Karla Fischera Pripravky na ochranu rostlin, jejichz ucinne latky nebo formulacni prisady nereaguji s pouzitym typem cinidla Stanoveni vody metodou podle Karl Fischera SOP-CH-07-01 (CIPAC MT 30.5)","search_en":"Plant protection products whose active substances or formulants do not react with the reagent used Determination of water pursuant to Karl Fischer SOP-CH-07-01 (CIPAC MT 30.5)","search_zh":"其活性成分或助剂不与所用试剂反应的植物保护产品 卡尔·费休法测定水分 SOP-CH-07-01 (CIPAC MT 30.5)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":226,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2e2cb54ac08784c3284559af","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"6","test_object":"Środki ochrony roślin – roztwory wodne","test_object_en":"Plant protection products – aqueous solutions","test_object_zh":"植物保护产品——水剂","test_object_cs":"Přípravky na ochranu rostlin – vodné roztoky","methodology":"Oznaczanie trwałości wodnych roztworów pestycydów po rozcieńczeniu metodą wizualną","methodology_en":"Determination of stability of pesticide aqueous solutions after dilution by visual method","methodology_zh":"目视法测定农药水溶液稀释后的稳定性","methodology_cs":"Stanovení stability pesticidních vodných roztoků po zředění vizuálně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie trwałości wodnych roztworów pestycydów po rozcieńczeniu metodą wizualną","reference":"SOP-FCH-07-06 (CIPAC MT 41.1)","norm_bases":["SOP-FCH-07-06","CIPAC MT 41.1"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin – roztwory wodne Oznaczanie trwałości wodnych roztworów pestycydów po rozcieńczeniu metodą wizualną Přípravky na ochranu rostlin – vodné roztoky Stanovení stability pesticidních vodných roztoků po zředění vizuálně SOP-FCH-07-06 (CIPAC MT 41.1) Srodki ochrony roslin – roztwory wodne Oznaczanie trwalosci wodnych roztworow pestycydow po rozcienczeniu metoda wizualna Pripravky na ochranu rostlin – vodne roztoky Stanoveni stability pesticidnich vodnych roztoku po zredeni vizualne SOP-FCH-07-06 (CIPAC MT 41.1)","search_en":"Plant protection products – aqueous solutions Determination of stability of pesticide aqueous solutions after dilution by visual method SOP-FCH-07-06 (CIPAC MT 41.1)","search_zh":"植物保护产品——水剂 目视法测定农药水溶液稀释后的稳定性 SOP-FCH-07-06 (CIPAC MT 41.1)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":227,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cda7364406b378a6109bf668","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"7","test_object":"Środki ochrony roślin – formulacje ciekłe","test_object_en":"Plant protection products – liquid formulations","test_object_zh":"植物保护产品——液体制剂","test_object_cs":"Přípravky na ochranu rostlin – kapalné formulace","methodology":"Oznaczanie trwałości formulacji ciekłych w temperaturze 0 °C metodą wizualną","methodology_en":"Determination of stability of liquid formulations at 0 °C by visual method","methodology_zh":"目视法测定液体制剂在0 °C下的稳定性","methodology_cs":"Stanovení stability kapalných formulací při 0 °C vizuálně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie trwałości formulacji ciekłych w temperaturze 0 °C metodą wizualną","reference":"SOP-FCH-07-03 (CIPAC MT 39.3)","norm_bases":["SOP-FCH-07-03","CIPAC MT 39.3"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin – formulacje ciekłe Oznaczanie trwałości formulacji ciekłych w temperaturze 0 °C metodą wizualną Přípravky na ochranu rostlin – kapalné formulace Stanovení stability kapalných formulací při 0 °C vizuálně SOP-FCH-07-03 (CIPAC MT 39.3) Srodki ochrony roslin – formulacje ciekle Oznaczanie trwalosci formulacji cieklych w temperaturze 0 °C metoda wizualna Pripravky na ochranu rostlin – kapalne formulace Stanoveni stability kapalnych formulaci pri 0 °C vizualne SOP-FCH-07-03 (CIPAC MT 39.3)","search_en":"Plant protection products – liquid formulations Determination of stability of liquid formulations at 0 °C by visual method SOP-FCH-07-03 (CIPAC MT 39.3)","search_zh":"植物保护产品——液体制剂 目视法测定液体制剂在0 °C下的稳定性 SOP-FCH-07-03 (CIPAC MT 39.3)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":228,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a24554359ffe369fa8ffbec2","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"8","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie wielkości cząstek metodą dyfrakcji laserowej","methodology_en":"Determination of particle size distribution by laser diffraction method","methodology_zh":"激光衍射法测定粒径","methodology_cs":"Stanovení velikosti částic metodou laserové difrakce","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wielkości cząstek metodą dyfrakcji laserowej","reference":"SOP-FCH-08-01 (CIPAC MT 187)","norm_bases":["SOP-FCH-08-01","CIPAC MT 187"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin Oznaczanie wielkości cząstek metodą dyfrakcji laserowej Přípravky na ochranu rostlin Stanovení velikosti částic metodou laserové difrakce SOP-FCH-08-01 (CIPAC MT 187) Srodki ochrony roslin Oznaczanie wielkosci czastek metoda dyfrakcji laserowej Pripravky na ochranu rostlin Stanoveni velikosti castic metodou laserove difrakce SOP-FCH-08-01 (CIPAC MT 187)","search_en":"Plant protection products Determination of particle size distribution by laser diffraction method SOP-FCH-08-01 (CIPAC MT 187)","search_zh":"植物保护产品 激光衍射法测定粒径 SOP-FCH-08-01 (CIPAC MT 187)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":229,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dac39ea03e07e2d22476d5b3","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"9","test_object":"Środki ochrony roślin stosowane jako dyspersja w wodzie","test_object_en":"Plant protection products applicable as dispersion in water","test_object_zh":"以水分散体形式施用的植物保护产品","test_object_cs":"Přípravky na ochranu rostlin aplikovatelné jako disperze ve vodě","methodology":"Oznaczanie pozostałości na sicie metodą wagową","methodology_en":"Determination of residue on sieve by gravimetric method","methodology_zh":"重量法测定筛余物","methodology_cs":"Stanovení zbytku na sítě gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pozostałości na sicie metodą wagową","reference":"SOP-FCH-08-03 (CIPAC MT 167)","norm_bases":["SOP-FCH-08-03","CIPAC MT 167"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin stosowane jako dyspersja w wodzie Oznaczanie pozostałości na sicie metodą wagową Přípravky na ochranu rostlin aplikovatelné jako disperze ve vodě Stanovení zbytku na sítě gravimetricky SOP-FCH-08-03 (CIPAC MT 167) Srodki ochrony roslin stosowane jako dyspersja w wodzie Oznaczanie pozostalosci na sicie metoda wagowa Pripravky na ochranu rostlin aplikovatelne jako disperze ve vode Stanoveni zbytku na site gravimetricky SOP-FCH-08-03 (CIPAC MT 167)","search_en":"Plant protection products applicable as dispersion in water Determination of residue on sieve by gravimetric method SOP-FCH-08-03 (CIPAC MT 167)","search_zh":"以水分散体形式施用的植物保护产品 重量法测定筛余物 SOP-FCH-08-03 (CIPAC MT 167)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":230,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7ef02aeff174207ddb0dd586","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"10","test_object":"Środki ochrony roślin – formulacje ciekłe","test_object_en":"Plant protection products – liquid formulations","test_object_zh":"植物保护产品——液体制剂","test_object_cs":"Přípravky na ochranu rostlin – kapalné formulace","methodology":"Oznaczanie wylewalności (pozostałości R) i pozostałości po wypłukaniu (r) metodą wagową","methodology_en":"Determination of pourability (residue R) and rinsed residue (r) by gravimetric method","methodology_zh":"重量法测定倾倒性（残留R）和冲洗残留（r）","methodology_cs":"Stanovení vylévatelnosti (zbytku R) a vypláchnutelného zbytku (r) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wylewalności (pozostałości R) i pozostałości po wypłukaniu (r) metodą wagową","reference":"SOP-FCH-08-02 (CIPAC MT 148; CIPAC MT 148.1)","norm_bases":["SOP-FCH-08-02","CIPAC MT 148","CIPAC MT 148.1"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin – formulacje ciekłe Oznaczanie wylewalności (pozostałości R) i pozostałości po wypłukaniu (r) metodą wagową Přípravky na ochranu rostlin – kapalné formulace Stanovení vylévatelnosti (zbytku R) a vypláchnutelného zbytku (r) gravimetricky SOP-FCH-08-02 (CIPAC MT 148; CIPAC MT 148.1) Srodki ochrony roslin – formulacje ciekle Oznaczanie wylewalnosci (pozostalosci R) i pozostalosci po wyplukaniu (r) metoda wagowa Pripravky na ochranu rostlin – kapalne formulace Stanoveni vylevatelnosti (zbytku R) a vyplachnutelneho zbytku (r) gravimetricky SOP-FCH-08-02 (CIPAC MT 148; CIPAC MT 148.1)","search_en":"Plant protection products – liquid formulations Determination of pourability (residue R) and rinsed residue (r) by gravimetric method SOP-FCH-08-02 (CIPAC MT 148; CIPAC MT 148.1)","search_zh":"植物保护产品——液体制剂 重量法测定倾倒性（残留R）和冲洗残留（r） SOP-FCH-08-02 (CIPAC MT 148; CIPAC MT 148.1)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":231,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eb48d3b4a1a013aaf2faf6d8","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"11","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie trwałego pienienia metodą wizualną","methodology_en":"Determination of persistent foaming by visual method","methodology_zh":"目视法测定持久起泡性","methodology_cs":"Stanovení persistentní pěnivosti vizuálně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie trwałego pienienia metodą wizualną","reference":"SOP-FCH-10-01 (CIPAC MT 47.2, 47.3)","norm_bases":["SOP-FCH-10-01","CIPAC MT 47.2, 47.3"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin Oznaczanie trwałego pienienia metodą wizualną Přípravky na ochranu rostlin Stanovení persistentní pěnivosti vizuálně SOP-FCH-10-01 (CIPAC MT 47.2, 47.3) Srodki ochrony roslin Oznaczanie trwalego pienienia metoda wizualna Pripravky na ochranu rostlin Stanoveni persistentni penivosti vizualne SOP-FCH-10-01 (CIPAC MT 47.2, 47.3)","search_en":"Plant protection products Determination of persistent foaming by visual method SOP-FCH-10-01 (CIPAC MT 47.2, 47.3)","search_zh":"植物保护产品 目视法测定持久起泡性 SOP-FCH-10-01 (CIPAC MT 47.2, 47.3)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":232,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9e236fc8046b77857939f450","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"12","test_object":"Środki ochrony roślin – koncentraty do sporządzania emulsji i emulsje olej w wodzie","test_object_en":"Plant protection products – emulsifiable concentrates and oil-in-water emulsions","test_object_zh":"植物保护产品——乳油和水乳剂","test_object_cs":"Přípravky na ochranu rostlin – emulgovatelné koncentráty a emulze typu olej ve vodě","methodology":"Oznaczanie trwałości emulsji formulacji EC i EW metodą wizualną","methodology_en":"Determination of emulsion stability of EC and EW formulations by visual method","methodology_zh":"目视法测定EC和EW制剂的乳液稳定性","methodology_cs":"Stanovení stability emulze EC a EW formulací vizuálně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie trwałości emulsji formulacji EC i EW metodą wizualną","reference":"SOP-FCH-10-02 (CIPAC MT 36.3)","norm_bases":["SOP-FCH-10-02","CIPAC MT 36.3"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin – koncentraty do sporządzania emulsji i emulsje olej w wodzie Oznaczanie trwałości emulsji formulacji EC i EW metodą wizualną Přípravky na ochranu rostlin – emulgovatelné koncentráty a emulze typu olej ve vodě Stanovení stability emulze EC a EW formulací vizuálně SOP-FCH-10-02 (CIPAC MT 36.3) Srodki ochrony roslin – koncentraty do sporzadzania emulsji i emulsje olej w wodzie Oznaczanie trwalosci emulsji formulacji EC i EW metoda wizualna Pripravky na ochranu rostlin – emulgovatelne koncentraty a emulze typu olej ve vode Stanoveni stability emulze EC a EW formulaci vizualne SOP-FCH-10-02 (CIPAC MT 36.3)","search_en":"Plant protection products – emulsifiable concentrates and oil-in-water emulsions Determination of emulsion stability of EC and EW formulations by visual method SOP-FCH-10-02 (CIPAC MT 36.3)","search_zh":"植物保护产品——乳油和水乳剂 目视法测定EC和EW制剂的乳液稳定性 SOP-FCH-10-02 (CIPAC MT 36.3)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":233,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a7790caa5b0d7d60b1baa818","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"13","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie popiołu siarczanowego metodą wagową","methodology_en":"Determination of sulphated ash by gravimetric method","methodology_zh":"重量法测定硫酸盐灰分","methodology_cs":"Stanovení síranového popele gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie popiołu siarczanowego metodą wagową","reference":"SOP-FCH-17-01 (CIPAC MT 29)","norm_bases":["SOP-FCH-17-01","CIPAC MT 29"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin Oznaczanie popiołu siarczanowego metodą wagową Přípravky na ochranu rostlin Stanovení síranového popele gravimetricky SOP-FCH-17-01 (CIPAC MT 29) Srodki ochrony roslin Oznaczanie popiolu siarczanowego metoda wagowa Pripravky na ochranu rostlin Stanoveni siranoveho popele gravimetricky SOP-FCH-17-01 (CIPAC MT 29)","search_en":"Plant protection products Determination of sulphated ash by gravimetric method SOP-FCH-17-01 (CIPAC MT 29)","search_zh":"植物保护产品 重量法测定硫酸盐灰分 SOP-FCH-17-01 (CIPAC MT 29)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":234,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8b665b5c7294ea2b368c81a6","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"14","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie napięcia powierzchniowego metodą tensjometryczną","methodology_en":"Determination of surface tension by tensiometric method","methodology_zh":"张力计法测定表面张力","methodology_cs":"Stanovení povrchového napětí tenziometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie napięcia powierzchniowego metodą tensjometryczną","reference":"SOP-FCH-17-02 (OECD 115)","norm_bases":["SOP-FCH-17-02","OECD 115"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin Oznaczanie napięcia powierzchniowego metodą tensjometryczną Přípravky na ochranu rostlin Stanovení povrchového napětí tenziometricky SOP-FCH-17-02 (OECD 115) Srodki ochrony roslin Oznaczanie napiecia powierzchniowego metoda tensjometryczna Pripravky na ochranu rostlin Stanoveni povrchoveho napeti tenziometricky SOP-FCH-17-02 (OECD 115)","search_en":"Plant protection products Determination of surface tension by tensiometric method SOP-FCH-17-02 (OECD 115)","search_zh":"植物保护产品 张力计法测定表面张力 SOP-FCH-17-02 (OECD 115)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":235,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"31a1a2e571e4221bb33737e8","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"15","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie dyspergowalności granul do sporządzania zawiesiny wodnej metodą wagową","methodology_en":"Determination of dispersibility of water dispersible granules by gravimetric method","methodology_zh":"重量法测定水分散粒剂的分散性","methodology_cs":"Stanovení dispergovatelnosti ve vodě dispergovatelných granulí gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie dyspergowalności granul do sporządzania zawiesiny wodnej metodą wagową","reference":"SOP-FCH-19-01 (CIPAC MT 174)","norm_bases":["SOP-FCH-19-01","CIPAC MT 174"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin Oznaczanie dyspergowalności granul do sporządzania zawiesiny wodnej metodą wagową Přípravky na ochranu rostlin Stanovení dispergovatelnosti ve vodě dispergovatelných granulí gravimetricky SOP-FCH-19-01 (CIPAC MT 174) Srodki ochrony roslin Oznaczanie dyspergowalnosci granul do sporzadzania zawiesiny wodnej metoda wagowa Pripravky na ochranu rostlin Stanoveni dispergovatelnosti ve vode dispergovatelnych granuli gravimetricky SOP-FCH-19-01 (CIPAC MT 174)","search_en":"Plant protection products Determination of dispersibility of water dispersible granules by gravimetric method SOP-FCH-19-01 (CIPAC MT 174)","search_zh":"植物保护产品 重量法测定水分散粒剂的分散性 SOP-FCH-19-01 (CIPAC MT 174)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":236,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e95b216d7dcfd576fd1902d4","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"16","test_object":"Środki ochrony roślin – formulacje ciekłe","test_object_en":"Plant protection products – liquid formulations","test_object_zh":"植物保护产品——液体制剂","test_object_cs":"Přípravky na ochranu rostlin – kapalné formulace","methodology":"Oznaczanie gęstości metodą oscylacyjnej rurki U","methodology_en":"Determination of density by oscillating U-tube method","methodology_zh":"振荡U形管法测定密度","methodology_cs":"Stanovení hustoty metodou oscilační U-trubice","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości metodą oscylacyjnej rurki U","reference":"SOP-FCH-24-01","norm_bases":["SOP-FCH-24-01"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin – formulacje ciekłe Oznaczanie gęstości metodą oscylacyjnej rurki U Přípravky na ochranu rostlin – kapalné formulace Stanovení hustoty metodou oscilační U-trubice SOP-FCH-24-01 Srodki ochrony roslin – formulacje ciekle Oznaczanie gestosci metoda oscylacyjnej rurki U Pripravky na ochranu rostlin – kapalne formulace Stanoveni hustoty metodou oscilacni U-trubice SOP-FCH-24-01","search_en":"Plant protection products – liquid formulations Determination of density by oscillating U-tube method SOP-FCH-24-01","search_zh":"植物保护产品——液体制剂 振荡U形管法测定密度 SOP-FCH-24-01","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":237,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d2ccae7f22f44a38c320f5ae","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"17","test_object":"Środki ochrony roślin – koncentraty do sporządzania emulsji","test_object_en":"Plant protection products – emulsifiable concentrates","test_object_zh":"植物保护产品——乳油","test_object_cs":"Přípravky na ochranu rostlin – emulgovatelné koncentráty","methodology":"Oznaczanie ksylenu w formulacjach EC metodą GC/FID","methodology_en":"Determination of xylene in EC formulations by GC/FID method","methodology_zh":"GC/FID法测定EC制剂中的二甲苯","methodology_cs":"Stanovení xylenu v EC formulacích metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ksylenu w formulacjach EC metodą GC/FID","reference":"SOP-CH-07-02","norm_bases":["SOP-CH-07-02"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin – koncentraty do sporządzania emulsji Oznaczanie ksylenu w formulacjach EC metodą GC/FID Přípravky na ochranu rostlin – emulgovatelné koncentráty Stanovení xylenu v EC formulacích metodou GC/FID SOP-CH-07-02 Srodki ochrony roslin – koncentraty do sporzadzania emulsji Oznaczanie ksylenu w formulacjach EC metoda GC/FID Pripravky na ochranu rostlin – emulgovatelne koncentraty Stanoveni xylenu v EC formulacich metodou GC/FID SOP-CH-07-02","search_en":"Plant protection products – emulsifiable concentrates Determination of xylene in EC formulations by GC/FID method SOP-CH-07-02","search_zh":"植物保护产品——乳油 GC/FID法测定EC制剂中的二甲苯 SOP-CH-07-02","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":238,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5d97adee5a3f452cae736f85","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"18","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie alkoholi dwu- i trójwodorotlenowych metodą GC/FID","methodology_en":"Determination of dihydric and trihydric alcohols by GC/FID method","methodology_zh":"GC/FID法测定二元醇和三元醇","methodology_cs":"Stanovení dvojsytných a trojsytných alkoholů metodou GC/FID","parameters":[{"name":"Glikol propylenowy","range":""},{"name":"glikol etylenowy","range":""},{"name":"glicerol","range":""},{"name":"1,6-heksanodiol","range":""}],"parameters_en":[{"name":"Propylene glycol","range":""},{"name":"ethylene glycol","range":""},{"name":"glycerol","range":""},{"name":"1,6-hexanediol","range":""}],"parameters_zh":[{"name":"丙二醇","range":""},{"name":"乙二醇","range":""},{"name":"甘油","range":""},{"name":"1,6-己二醇","range":""}],"parameters_cs":[{"name":"Propylenglykol","range":""},{"name":"ethylenglykol","range":""},{"name":"glycerol","range":""},{"name":"1,6-hexandiol","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie alkoholi dwu- i trójwodorotlenowych metodą GC/FID\nZakres:\nGlikol propylenowy\nglikol etylenowy\nglicerol\n1,6-heksanodiol","reference":"SOP-CH-14-01","norm_bases":["SOP-CH-14-01"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin Oznaczanie alkoholi dwu- i trójwodorotlenowych metodą GC/FID Glikol propylenowy  glikol etylenowy  glicerol  1,6-heksanodiol  Přípravky na ochranu rostlin Stanovení dvojsytných a trojsytných alkoholů metodou GC/FID Propylenglykol  ethylenglykol  glycerol  1,6-hexandiol  SOP-CH-14-01 Srodki ochrony roslin Oznaczanie alkoholi dwu- i trojwodorotlenowych metoda GC/FID Glikol propylenowy  glikol etylenowy  glicerol  1,6-heksanodiol  Pripravky na ochranu rostlin Stanoveni dvojsytnych a trojsytnych alkoholu metodou GC/FID Propylenglykol  ethylenglykol  glycerol  1,6-hexandiol  SOP-CH-14-01","search_en":"Plant protection products Determination of dihydric and trihydric alcohols by GC/FID method Propylene glycol  ethylene glycol  glycerol  1,6-hexanediol  SOP-CH-14-01","search_zh":"植物保护产品 GC/FID法测定二元醇和三元醇 丙二醇  乙二醇  甘油  1,6-己二醇  SOP-CH-14-01","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":239,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"86019a5d8ca70398f8666af9","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"19","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie toluenu metodą HS-GC/FID","methodology_en":"Determination of toluene by HS-GC/FID method","methodology_zh":"HS-GC/FID法测定甲苯","methodology_cs":"Stanovení toluenu metodou HS-GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie toluenu metodą HS-GC/FID","reference":"SOP-CH-17-01 (CIPAC MT 198)","norm_bases":["SOP-CH-17-01","CIPAC MT 198"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin Oznaczanie toluenu metodą HS-GC/FID Přípravky na ochranu rostlin Stanovení toluenu metodou HS-GC/FID SOP-CH-17-01 (CIPAC MT 198) Srodki ochrony roslin Oznaczanie toluenu metoda HS-GC/FID Pripravky na ochranu rostlin Stanoveni toluenu metodou HS-GC/FID SOP-CH-17-01 (CIPAC MT 198)","search_en":"Plant protection products Determination of toluene by HS-GC/FID method SOP-CH-17-01 (CIPAC MT 198)","search_zh":"植物保护产品 HS-GC/FID法测定甲苯 SOP-CH-17-01 (CIPAC MT 198)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":240,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f04884ad8b2519f4f2fb65be","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"20","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie składników formulacji i zanieczyszczeń w ŚOR metodą GC/MS","methodology_en":"Determination of formulation additives and impurities in PPP by GC/MS method","methodology_zh":"GC/MS法测定植保产品中的助剂和杂质","methodology_cs":"Stanovení formulačních přísad a nečistot v POR metodou GC/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie składników formulacji i zanieczyszczeń w ŚOR metodą GC/MS","reference":"SOP-CH-19-01","norm_bases":["SOP-CH-19-01"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: 1,2,3-TMB, 1,2,4-TMB, 1-butanol, 1-metylonaftalen, 1-pentanol, 2-etylo-1-heksanol, 2-metylo-1-butanol, 2-metylonaftalen, 1-metylo-2-pirolidon, acetofenon, alkohol benzylowy, butyloglikol, butylowany hydroksytoluen, kumen, cykloheksanon, alkohol diacetonowy, adypinian dimetylu, glutaran dimetylu, bursztynian dimetylu, EMS, etylobenzen, gamma-butyrolakton, IBMS, izobutanol, mirystynian izopropylu, mezytylen, oktanian metylu, naftalen, fenetol, węglan propylenu, toluen, ksylen","note_en":"Determined analytes: 1,2,3-TMB, 1,2,4-TMB, 1-butanol, 1-methylnaphthalene, 1-pentanol, 2-ethyl-1-hexanol, 2-methyl-1-butanol, 2-methylnaphthalene, 1-methyl-2-pyrrolidone, acetophenone, benzyl alcohol, butyl glycol, butylated hydroxytoluene, cumene, cyclohexanone, diacetone alcohol, dimethyl adipate, dimethyl glutarate, dimethyl succinate, EMS, ethylbenzene, gamma-butyrolactone, IBMS, isobutanol, isopropyl myristate, mesitylene, methyl octanoate, naphthalene, phenetole, propylene carbonate, toluene, xylene","note_zh":"测定分析物：1,2,3-TMB, 1,2,4-TMB, 1-butanol, 1-methylnaphthalene, 1-pentanol, 2-ethyl-1-hexanol, 2-methyl-1-butanol, 2-methylnaphthalene, 1-methyl-2-pyrrolidone, acetophenone, benzyl alcohol, butyl glycol, butylated hydroxytoluene, cumene, cyclohexanone, diacetone alcohol, dimethyl adipate, dimethyl glutarate, dimethyl succinate, EMS, ethylbenzene, gamma-butyrolactone, IBMS, isobutanol, isopropyl myristate, mesitylene, methyl octanoate, naphthalene, phenetole, propylene carbonate, toluene, xylene","note_cs":"Stanovované analyty: 1,2,3-TMB, 1,2,4-TMB, 1-butanol, 1-methylnaftalen, 1-pentanol, 2-ethyl-1-hexanol, 2-methyl-1-butanol, 2-methylnaftalen, 1-methyl-2-pyrollidone, acetophenone, benzyl alcohol, butyl glycol, butylovaný hydroxytoluen, cumen, cyklohexanon, diaceton alcohol, dimethyl adipate, dimethyl glutarate, dimethyl succinate, EMS, ethylbenzen, gamma-butyrolactone, IBMS, isobutanol, isopropyl myristate, mesitylene, methyl octanoate, naftalen, phenetole, propylene carbonate, toluen, xylen","search_text":"Środki ochrony roślin Oznaczanie składników formulacji i zanieczyszczeń w ŚOR metodą GC/MS Přípravky na ochranu rostlin Stanovení formulačních přísad a nečistot v POR metodou GC/MS SOP-CH-19-01 Srodki ochrony roslin Oznaczanie skladnikow formulacji i zanieczyszczen w SOR metoda GC/MS Pripravky na ochranu rostlin Stanoveni formulacnich prisad a necistot v POR metodou GC/MS SOP-CH-19-01","search_en":"Plant protection products Determination of formulation additives and impurities in PPP by GC/MS method SOP-CH-19-01","search_zh":"植物保护产品 GC/MS法测定植保产品中的助剂和杂质 SOP-CH-19-01","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":241,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"90be16b85a004bf50688d21d","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"21","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie substancji czynnych w ŚOR metodą GC/FID","methodology_en":"Determination of active substances in PPP by GC/FID method","methodology_zh":"GC/FID法测定植保产品中的活性成分","methodology_cs":"Stanovení účinných látek v POR metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji czynnych w ŚOR metodą GC/FID","reference":"SOP-CH-19-02","norm_bases":["SOP-CH-19-02"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: 2,4-D EHE, aclonifen, ametryn, azoxystrobin, bixafen, clomazone, cyflufenamid, cypermethrin, cyproconazole, deltamethrin, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimoxystrobin, epoxiconazole, ethofumesate, fenhexamid, fludioxonil, flurochloridone, fluroxypyr-meptyl, lambda-cyhalothrin, metalaxyl-M, metamitron, metazachlor, metconazole, metolachlor, metribuzin, myclobutanil, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, piperonyl butoxide, pirimiphos-methyl, propiconazole, prosulfocarb, pyraclostrobin, pyraflufen-ethyl, quizalofop-P-ethyl, silthiofam, spiroxamine, tebuconazole, terbuthylazine, thiabendazole, trifloxystrobin, trifluralin, trinexapac-ethyl, zoxamide","note_en":"Determined analytes: 2,4-D EHE, aclonifen, ametryn, azoxystrobin, bixafen, clomazone, cyflufenamid, cypermethrin, cyproconazole, deltamethrin, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimoxystrobin, epoxiconazole, ethofumesate, fenhexamid, fludioxonil, flurochloridone, fluroxypyr-meptyl, lambda-cyhalothrin, metalaxyl-M, metamitron, metazachlor, metconazole, metolachlor, metribuzin, myclobutanil, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, piperonyl butoxide, pirimiphos-methyl, propiconazole, prosulfocarb, pyraclostrobin, pyraflufen-ethyl, quizalofop-P-ethyl, silthiofam, spiroxamine, tebuconazole, terbuthylazine, thiabendazole, trifloxystrobin, trifluralin, trinexapac-ethyl, zoxamide","note_zh":"测定分析物：2,4-D EHE, aclonifen, ametryn, azoxystrobin, bixafen, clomazone, cyflufenamid, cypermethrin, cyproconazole, deltamethrin, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimoxystrobin, epoxiconazole, ethofumesate, fenhexamid, fludioxonil, flurochloridone, fluroxypyr-meptyl, lambda-cyhalothrin, metalaxyl-M, metamitron, metazachlor, metconazole, metolachlor, metribuzin, myclobutanil, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, piperonyl butoxide, pirimiphos-methyl, propiconazole, prosulfocarb, pyraclostrobin, pyraflufen-ethyl, quizalofop-P-ethyl, silthiofam, spiroxamine, tebuconazole, terbuthylazine, thiabendazole, trifloxystrobin, trifluralin, trinexapac-ethyl, zoxamide","note_cs":"Stanovované analyty: 2,4-D EHE, aclonifen, ametryn, azoxystrobin, bixafen, clomazone, cyflufenamid, cypermethrin, cyproconazole, deltamethrin, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimoxystrobin, epoxiconazole, ethofumesate, fenhexamid, fludioxonil, flurochloridon, fluroxypyr-meptyl, lambda-cyhalothrin, metalaxyl-M, metamitron, metazachlor, metconazole, metolachlor, metribuzin, myclobutanil, napropamid, paclobutrazol, pendimethalin, permethrin, pethoxamid, piperonyl butoxide, pirimiphos-methyl, propiconazole, prosulfocarb, pyraclostrobin, pyraflufen-ethyl, quizalofop-P-ethyl, silthiofam, spiroxamin, tebuconazole, terbuthylazin, thiabendazole, trifloxystrobin, trifluralin, trinexapac-ethyl, zoxamide","search_text":"Środki ochrony roślin Oznaczanie substancji czynnych w ŚOR metodą GC/FID Přípravky na ochranu rostlin Stanovení účinných látek v POR metodou GC/FID SOP-CH-19-02 Srodki ochrony roslin Oznaczanie substancji czynnych w SOR metoda GC/FID Pripravky na ochranu rostlin Stanoveni ucinnych latek v POR metodou GC/FID SOP-CH-19-02","search_en":"Plant protection products Determination of active substances in PPP by GC/FID method SOP-CH-19-02","search_zh":"植物保护产品 GC/FID法测定植保产品中的活性成分 SOP-CH-19-02","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":242,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e473e2dece56ae56667ccb0c","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"22","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie substancji czynnych w ŚOR metodą LC/UV","methodology_en":"Determination of active substances in PPP by LC/UV method","methodology_zh":"LC/UV法测定植保产品中的活性成分","methodology_cs":"Stanovení účinných látek v POR metodou LC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji czynnych w ŚOR metodą LC/UV","reference":"SOP-CH-19-03","norm_bases":["SOP-CH-19-03"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: 2,4-D, acetamiprid, aclonifen, ametoctradin, azoxystrobin, bentazone, boscalid, captan, clomazone, cloquintocet-mexyl, cymoxanil, cypermethrin, cyproconazole, cyprodinil, deltamethrin, dicamba, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimethomorph, dimoxystrobin, dithianon, epoxiconazole, fenhexamid, fipronil, florasulam, fludioxonil, flufenacet, flumioxazin, fluroxypyr-meptyl, flurprimidol, folpet, gibberellin, hexythiazox, chlortoluron, imazamox, imidacloprid, isofetamid, isoxaben, cyazofamid, lambda-cyhalothrin, mandipropamid, mecoprop-P, mefentrifluconazole, metamitron, metazachlor, metconazole, metrafenone, metribuzin, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, phenmedipham, picloram, pinoxaden, prosulfocarb, prothioconazole, pyraclostrobin, pyridate, quizalofop-p-ethyl, sedaxane, silthiofam, s-metolachlor, spinetoram, spinosad, spirotetramat, tau-fluvalinate, tebuconazole, tefluthrin, terbuthylazine, thiacloprid, thiamethoxam, thiophanate-methyl, triclopyr, trifloxystrobin, trifluralin, triflusulfuron-methyl, trinexapac-ethyl, triticonazole, zoxamide","note_en":"Determined analytes: 2,4-D, acetamiprid, aclonifen, ametoctradin, azoxystrobin, bentazone, boscalid, captan, clomazone, cloquintocet-mexyl, cymoxanil, cypermethrin, cyproconazole, cyprodinil, deltamethrin, dicamba, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimethomorph, dimoxystrobin, dithianon, epoxiconazole, fenhexamid, fipronil, florasulam, fludioxonil, flufenacet, flumioxazin, fluroxypyr-meptyl, flurprimidol, folpet, gibberellin, hexythiazox, chlortoluron, imazamox, imidacloprid, isofetamid, isoxaben, cyazofamid, lambda-cyhalothrin, mandipropamid, mecoprop-P, mefentrifluconazole, metamitron, metazachlor, metconazole, metrafenone, metribuzin, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, phenmedipham, picloram, pinoxaden, prosulfocarb, prothioconazole, pyraclostrobin, pyridate, quizalofop-p-ethyl, sedaxane, silthiofam, s-metolachlor, spinetoram, spinosad, spirotetramat, tau-fluvalinate, tebuconazole, tefluthrin, terbuthylazine, thiacloprid, thiamethoxam, thiophanate-methyl, triclopyr, trifloxystrobin, trifluralin, triflusulfuron-methyl, trinexapac-ethyl, triticonazole, zoxamide","note_zh":"测定分析物：2,4-D, acetamiprid, aclonifen, ametoctradin, azoxystrobin, bentazone, boscalid, captan, clomazone, cloquintocet-mexyl, cymoxanil, cypermethrin, cyproconazole, cyprodinil, deltamethrin, dicamba, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimethomorph, dimoxystrobin, dithianon, epoxiconazole, fenhexamid, fipronil, florasulam, fludioxonil, flufenacet, flumioxazin, fluroxypyr-meptyl, flurprimidol, folpet, gibberellin, hexythiazox, chlortoluron, imazamox, imidacloprid, isofetamid, isoxaben, cyazofamid, lambda-cyhalothrin, mandipropamid, mecoprop-P, mefentrifluconazole, metamitron, metazachlor, metconazole, metrafenone, metribuzin, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, phenmedipham, picloram, pinoxaden, prosulfocarb, prothioconazole, pyraclostrobin, pyridate, quizalofop-p-ethyl, sedaxane, silthiofam, s-metolachlor, spinetoram, spinosad, spirotetramat, tau-fluvalinate, tebuconazole, tefluthrin, terbuthylazine, thiacloprid, thiamethoxam, thiophanate-methyl, triclopyr, trifloxystrobin, trifluralin, triflusulfuron-methyl, trinexapac-ethyl, triticonazole, zoxamide","note_cs":"Stanovované analyty: 2,4-D, acetamiprid, aclonifen, ametoktradin, azoxystrobin, bentazone, boscalid, captan, clomazone, cloquintocet-mexyl, cymoxanil, cypermethrin, cyproconazole, cyprodinil, deltamethrin, dicamba, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimethomorph, dimoxystrobin, dithianon, epoxiconazole, fenhexamid, fipronil, florasulam, fludioxonil, flufenacet, flumioxazin, fluroxypyr-meptyl, flurprimidol, folpet, giberelin, hexythiazox, chlortoluron, imazamox, imidacloprid, isofetamid, isoxaben, kyazofamid, lambda-cyhalothrin, mandipropamid, mecoprop-P, mefentrifluconazole, metamitron, metazachlor, metconazole, metrafenon, metribuzin, napropamid, paclobutrazol, pendimethalin, permethrin, pethoxamid, phenmedipham, picloram, pinoxaden, prosulfocarb, prothioconazole, pyraclostrobin, pyridate, quizalofop-p-ethyl, sedaxane, silthiofam, s-metolachlor, spinetoram, spinosad, spirotetramat, tau-fluvalinat, tebuconazole, tefluthrin, terbuthylazine, thiacloprid, thimethoxam, thiophanate-methyl, triclopyr, trifloxystrobin, trifluralin, triflusulfuron-methyl, trinexapac-ethyl, triticonazole, zoxamide","search_text":"Środki ochrony roślin Oznaczanie substancji czynnych w ŚOR metodą LC/UV Přípravky na ochranu rostlin Stanovení účinných látek v POR metodou LC/UV SOP-CH-19-03 Srodki ochrony roslin Oznaczanie substancji czynnych w SOR metoda LC/UV Pripravky na ochranu rostlin Stanoveni ucinnych latek v POR metodou LC/UV SOP-CH-19-03","search_en":"Plant protection products Determination of active substances in PPP by LC/UV method SOP-CH-19-03","search_zh":"植物保护产品 LC/UV法测定植保产品中的活性成分 SOP-CH-19-03","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":243,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"17de8660e2890b9aaed2490f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"23","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie pylistości formulacji granulowanych metodą wagową","methodology_en":"Determination of dustiness of granulated formulations by gravimetric method","methodology_zh":"重量法测定颗粒制剂的粉尘度","methodology_cs":"Stanovení prašnosti granulovaných formulací gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pylistości formulacji granulowanych metodą wagową","reference":"SOP-FCH-19-06 (CIPAC MT 171.1)","norm_bases":["SOP-FCH-19-06","CIPAC MT 171.1"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin Oznaczanie pylistości formulacji granulowanych metodą wagową Přípravky na ochranu rostlin Stanovení prašnosti granulovaných formulací gravimetricky SOP-FCH-19-06 (CIPAC MT 171.1) Srodki ochrony roslin Oznaczanie pylistosci formulacji granulowanych metoda wagowa Pripravky na ochranu rostlin Stanoveni prasnosti granulovanych formulaci gravimetricky SOP-FCH-19-06 (CIPAC MT 171.1)","search_en":"Plant protection products Determination of dustiness of granulated formulations by gravimetric method SOP-FCH-19-06 (CIPAC MT 171.1)","search_zh":"植物保护产品 重量法测定颗粒制剂的粉尘度 SOP-FCH-19-06 (CIPAC MT 171.1)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":244,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2777dc67fd3a24b6c32c8b86","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"24","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie rozpuszczalności i trwałości roztworu metodą wagową","methodology_en":"Determination of solubility and solution stability by gravimetric method","methodology_zh":"重量法测定溶解性和溶液稳定性","methodology_cs":"Stanovení rozpustnosti a stability roztoku gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rozpuszczalności i trwałości roztworu metodą wagową","reference":"SOP-FCH-19-05 (CIPAC MT 179, 179.1)","norm_bases":["SOP-FCH-19-05","CIPAC MT 179, 179.1"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin Oznaczanie rozpuszczalności i trwałości roztworu metodą wagową Přípravky na ochranu rostlin Stanovení rozpustnosti a stability roztoku gravimetricky SOP-FCH-19-05 (CIPAC MT 179, 179.1) Srodki ochrony roslin Oznaczanie rozpuszczalnosci i trwalosci roztworu metoda wagowa Pripravky na ochranu rostlin Stanoveni rozpustnosti a stability roztoku gravimetricky SOP-FCH-19-05 (CIPAC MT 179, 179.1)","search_en":"Plant protection products Determination of solubility and solution stability by gravimetric method SOP-FCH-19-05 (CIPAC MT 179, 179.1)","search_zh":"植物保护产品 重量法测定溶解性和溶液稳定性 SOP-FCH-19-05 (CIPAC MT 179, 179.1)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":245,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a99f33ae7116ba5d95bf9ddb","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"25","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie trwałości dyspersji suspoemulsji metodą wizualną","methodology_en":"Determination of dispersion stability of suspo-emulsions by visual method","methodology_zh":"目视法测定悬乳剂的分散稳定性","methodology_cs":"Stanovení disperzní stability suspoemulzí vizuálně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie trwałości dyspersji suspoemulsji metodą wizualną","reference":"SOP-FCH-19-04 (CIPAC MT 180)","norm_bases":["SOP-FCH-19-04","CIPAC MT 180"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin Oznaczanie trwałości dyspersji suspoemulsji metodą wizualną Přípravky na ochranu rostlin Stanovení disperzní stability suspoemulzí vizuálně SOP-FCH-19-04 (CIPAC MT 180) Srodki ochrony roslin Oznaczanie trwalosci dyspersji suspoemulsji metoda wizualna Pripravky na ochranu rostlin Stanoveni disperzni stability suspoemulzi vizualne SOP-FCH-19-04 (CIPAC MT 180)","search_en":"Plant protection products Determination of dispersion stability of suspo-emulsions by visual method SOP-FCH-19-04 (CIPAC MT 180)","search_zh":"植物保护产品 目视法测定悬乳剂的分散稳定性 SOP-FCH-19-04 (CIPAC MT 180)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":246,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bf14f3f4aaf57f5e17a241ab","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"26","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie zawiesinowości formulacji tworzących zawiesiny po rozcieńczeniu wodą metodą wagową","methodology_en":"Determination of suspensibility of formulations forming suspensions on dilution with water by gravimetric method","methodology_zh":"重量法测定兑水稀释后形成悬浮液制剂的悬浮率","methodology_cs":"Stanovení suspendovatelnosti formulací tvořících suspenze po zředění vodou gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesinowości formulacji tworzących zawiesiny po rozcieńczeniu wodą metodą wagową","reference":"SOP-FCH-19-02 (CIPAC MT 184, 184.1)","norm_bases":["SOP-FCH-19-02","CIPAC MT 184, 184.1"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin Oznaczanie zawiesinowości formulacji tworzących zawiesiny po rozcieńczeniu wodą metodą wagową Přípravky na ochranu rostlin Stanovení suspendovatelnosti formulací tvořících suspenze po zředění vodou gravimetricky SOP-FCH-19-02 (CIPAC MT 184, 184.1) Srodki ochrony roslin Oznaczanie zawiesinowosci formulacji tworzacych zawiesiny po rozcienczeniu woda metoda wagowa Pripravky na ochranu rostlin Stanoveni suspendovatelnosti formulaci tvoricich suspenze po zredeni vodou gravimetricky SOP-FCH-19-02 (CIPAC MT 184, 184.1)","search_en":"Plant protection products Determination of suspensibility of formulations forming suspensions on dilution with water by gravimetric method SOP-FCH-19-02 (CIPAC MT 184, 184.1)","search_zh":"植物保护产品 重量法测定兑水稀释后形成悬浮液制剂的悬浮率 SOP-FCH-19-02 (CIPAC MT 184, 184.1)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":247,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"44bff37e10a32831db8fb782","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"27","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie zawiesinowości formulacji tworzących zawiesiny po rozcieńczeniu wodą metodą GC/FID","methodology_en":"Determination of suspensibility of formulations forming suspensions on dilution with water by GC/FID method","methodology_zh":"GC/FID法测定兑水稀释后形成悬浮液制剂的悬浮率","methodology_cs":"Stanovení suspendovatelnosti formulací tvořících suspenze po zředění vodou metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesinowości formulacji tworzących zawiesiny po rozcieńczeniu wodą metodą GC/FID","reference":"SOP-FCH-19-02 (CIPAC MT 184, 184.1)","norm_bases":["SOP-FCH-19-02","CIPAC MT 184, 184.1"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: 2,4-D EHE, aclonifen, ametryn, azoxystrobin, bixafen, clomazone, cyflufenamid, cypermethrin, cyproconazole, deltamethrin, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimoxystrobin, epoxiconazole, ethofumesate, fenhexamid, fludioxonil, flurochloridone, fluroxypyr-meptyl, lambda-cyhalothrin, metalaxyl-M, metamitron, metazachlor, metconazole, metolachlor, metribuzin, myclobutanil, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, piperonyl butoxide, pirimiphos-methyl, propiconazole, prosulfocarb, pyraclostrobin, pyraflufen-ethyl, quizalofop-P-ethyl, silthiofam, spiroxamine, tebuconazole, terbuthylazine, thiabendazole, trifloxystrobin, trifluralin, trinexapac-ethyl, zoxamide","note_en":"Determined analytes: 2,4-D EHE, aclonifen, ametryn, azoxystrobin, bixafen, clomazone, cyflufenamid, cypermethrin, cyproconazole, deltamethrin, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimoxystrobin, epoxiconazole, ethofumesate, fenhexamid, fludioxonil, flurochloridone, fluroxypyr-meptyl, lambda-cyhalothrin, metalaxyl-M, metamitron, metazachlor, metconazole, metolachlor, metribuzin, myclobutanil, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, piperonyl butoxide, pirimiphos-methyl, propiconazole, prosulfocarb, pyraclostrobin, pyraflufen-ethyl, quizalofop-P-ethyl, silthiofam, spiroxamine, tebuconazole, terbuthylazine, thiabendazole, trifloxystrobin, trifluralin, trinexapac-ethyl, zoxamide","note_zh":"测定分析物：2,4-D EHE, aclonifen, ametryn, azoxystrobin, bixafen, clomazone, cyflufenamid, cypermethrin, cyproconazole, deltamethrin, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimoxystrobin, epoxiconazole, ethofumesate, fenhexamid, fludioxonil, flurochloridone, fluroxypyr-meptyl, lambda-cyhalothrin, metalaxyl-M, metamitron, metazachlor, metconazole, metolachlor, metribuzin, myclobutanil, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, piperonyl butoxide, pirimiphos-methyl, propiconazole, prosulfocarb, pyraclostrobin, pyraflufen-ethyl, quizalofop-P-ethyl, silthiofam, spiroxamine, tebuconazole, terbuthylazine, thiabendazole, trifloxystrobin, trifluralin, trinexapac-ethyl, zoxamide","note_cs":"Stanovované analyty: 2,4-D EHE, aclonifen, ametryn, azoxystrobin, bixafen, clomazone, cyflufenamid, cypermethrin, cyproconazole, deltamethrin, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimoxystrobin, epoxiconazole, ethofumesate, fenhexamid, fludioxonil, flurochloridon, fluroxypyr-meptyl, lambda-cyhalothrin, metalaxyl-M, metamitron, metazachlor, metconazole, metolachlor, metribuzin, myclobutanil, napropamid, paclobutrazol, pendimethalin, permethrin, pethoxamid, piperonyl butoxide, pirimiphos-methyl, propiconazole, prosulfocarb, pyraclostrobin, pyraflufen-ethyl, quizalofop-P-ethyl, silthiofam, spiroxamin, tebuconazole, terbuthylazin, thiabendazole, trifloxystrobin, trifluralin, trinexapac-ethyl, zoxamide","search_text":"Środki ochrony roślin Oznaczanie zawiesinowości formulacji tworzących zawiesiny po rozcieńczeniu wodą metodą GC/FID Přípravky na ochranu rostlin Stanovení suspendovatelnosti formulací tvořících suspenze po zředění vodou metodou GC/FID SOP-FCH-19-02 (CIPAC MT 184, 184.1) Srodki ochrony roslin Oznaczanie zawiesinowosci formulacji tworzacych zawiesiny po rozcienczeniu woda metoda GC/FID Pripravky na ochranu rostlin Stanoveni suspendovatelnosti formulaci tvoricich suspenze po zredeni vodou metodou GC/FID SOP-FCH-19-02 (CIPAC MT 184, 184.1)","search_en":"Plant protection products Determination of suspensibility of formulations forming suspensions on dilution with water by GC/FID method SOP-FCH-19-02 (CIPAC MT 184, 184.1)","search_zh":"植物保护产品 GC/FID法测定兑水稀释后形成悬浮液制剂的悬浮率 SOP-FCH-19-02 (CIPAC MT 184, 184.1)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":248,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b21e8731a67ae364bdd2bb9b","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"28","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie zawiesinowości formulacji tworzących zawiesiny po rozcieńczeniu wodą metodą LC/UV","methodology_en":"Determination of suspensibility of formulations forming suspensions on dilution with water by LC/UV method","methodology_zh":"LC/UV法测定兑水稀释后形成悬浮液制剂的悬浮率","methodology_cs":"Stanovení suspendovatelnosti formulací tvořících suspenze po zředění vodou metodou LC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesinowości formulacji tworzących zawiesiny po rozcieńczeniu wodą metodą LC/UV","reference":"SOP-FCH-19-02 (CIPAC MT 184, 184.1)","norm_bases":["SOP-FCH-19-02","CIPAC MT 184, 184.1"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: 2,4-D, acetamiprid, aclonifen, ametoctradin, azoxystrobin, bentazone, boscalid, captan, clomazone, cloquintocet-mexyl, cymoxanil, cypermethrin, cyproconazole, cyprodinil, deltamethrin, dicamba, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimethomorph, dimoxystrobin, dithianon, epoxiconazole, fenhexamid, fipronil, florasulam, fludioxonil, flufenacet, flumioxazin, fluroxypyr-meptyl, flurprimidol, folpet, gibberellin, hexythiazox, chlortoluron, imazamox, imidacloprid, isofetamid, isoxaben, cyazofamid, lambda-cyhalothrin, mandipropamid, mecoprop-P, mefentrifluconazole, metamitron, metazachlor, metconazole, metrafenone, metribuzin, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, phenmedipham, picloram, pinoxaden, prosulfocarb, prothioconazole, pyraclostrobin, pyridate, quizalofop-p-ethyl, sedaxane, silthiofam, s-metolachlor, spinetoram, spinosad, spirotetramat, tau-fluvalinate, tebuconazole, tefluthrin, terbuthylazine, thiacloprid, thiamethoxam, thiophanate-methyl, triclopyr, trifloxystrobin, trifluralin, triflusulfuron-methyl, trinexapac-ethyl, triticonazole, zoxamide","note_en":"Determined analytes: 2,4-D, acetamiprid, aclonifen, ametoctradin, azoxystrobin, bentazone, boscalid, captan, clomazone, cloquintocet-mexyl, cymoxanil, cypermethrin, cyproconazole, cyprodinil, deltamethrin, dicamba, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimethomorph, dimoxystrobin, dithianon, epoxiconazole, fenhexamid, fipronil, florasulam, fludioxonil, flufenacet, flumioxazin, fluroxypyr-meptyl, flurprimidol, folpet, gibberellin, hexythiazox, chlortoluron, imazamox, imidacloprid, isofetamid, isoxaben, cyazofamid, lambda-cyhalothrin, mandipropamid, mecoprop-P, mefentrifluconazole, metamitron, metazachlor, metconazole, metrafenone, metribuzin, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, phenmedipham, picloram, pinoxaden, prosulfocarb, prothioconazole, pyraclostrobin, pyridate, quizalofop-p-ethyl, sedaxane, silthiofam, s-metolachlor, spinetoram, spinosad, spirotetramat, tau-fluvalinate, tebuconazole, tefluthrin, terbuthylazine, thiacloprid, thiamethoxam, thiophanate-methyl, triclopyr, trifloxystrobin, trifluralin, triflusulfuron-methyl, trinexapac-ethyl, triticonazole, zoxamide","note_zh":"测定分析物：2,4-D, acetamiprid, aclonifen, ametoctradin, azoxystrobin, bentazone, boscalid, captan, clomazone, cloquintocet-mexyl, cymoxanil, cypermethrin, cyproconazole, cyprodinil, deltamethrin, dicamba, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimethomorph, dimoxystrobin, dithianon, epoxiconazole, fenhexamid, fipronil, florasulam, fludioxonil, flufenacet, flumioxazin, fluroxypyr-meptyl, flurprimidol, folpet, gibberellin, hexythiazox, chlortoluron, imazamox, imidacloprid, isofetamid, isoxaben, cyazofamid, lambda-cyhalothrin, mandipropamid, mecoprop-P, mefentrifluconazole, metamitron, metazachlor, metconazole, metrafenone, metribuzin, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, phenmedipham, picloram, pinoxaden, prosulfocarb, prothioconazole, pyraclostrobin, pyridate, quizalofop-p-ethyl, sedaxane, silthiofam, s-metolachlor, spinetoram, spinosad, spirotetramat, tau-fluvalinate, tebuconazole, tefluthrin, terbuthylazine, thiacloprid, thiamethoxam, thiophanate-methyl, triclopyr, trifloxystrobin, trifluralin, triflusulfuron-methyl, trinexapac-ethyl, triticonazole, zoxamide","note_cs":"Stanovované analyty: 2,4-D, acetamiprid, aclonifen, ametoktradin, azoxystrobin, bentazone, boscalid, captan, clomazone, cloquintocet-mexyl, cymoxanil, cypermethrin, cyproconazole, cyprodinil, deltamethrin, dicamba, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimethomorph, dimoxystrobin, dithianon, epoxiconazole, fenhexamid, fipronil, florasulam, fludioxonil, flufenacet, flumioxazin, fluroxypyr-meptyl, flurprimidol, folpet, giberelin, hexythiazox, chlortoluron, imazamox, imidacloprid, isofetamid, isoxaben, kyazofamid, lambda-cyhalothrin, mandipropamid, mecoprop-P, mefentrifluconazole, metamitron, metazachlor, metconazole, metrafenon, metribuzin, napropamid, paclobutrazol, pendimethalin, permethrin, pethoxamid, phenmedipham, picloram, pinoxaden, prosulfocarb, prothioconazole, pyraclostrobin, pyridate, quizalofop-p-ethyl, sedaxane, silthiofam, s-metolachlor, spinetoram, spinosad, spirotetramat, tau-fluvalinat, tebuconazole, tefluthrin, terbuthylazine, thiacloprid, thimethoxam, thiophanate-methyl, triclopyr, trifloxystrobin, trifluralin, triflusulfuron-methyl, trinexapac-ethyl, triticonazole, zoxamide","search_text":"Środki ochrony roślin Oznaczanie zawiesinowości formulacji tworzących zawiesiny po rozcieńczeniu wodą metodą LC/UV Přípravky na ochranu rostlin Stanovení suspendovatelnosti formulací tvořících suspenze po zředění vodou metodou LC/UV SOP-FCH-19-02 (CIPAC MT 184, 184.1) Srodki ochrony roslin Oznaczanie zawiesinowosci formulacji tworzacych zawiesiny po rozcienczeniu woda metoda LC/UV Pripravky na ochranu rostlin Stanoveni suspendovatelnosti formulaci tvoricich suspenze po zredeni vodou metodou LC/UV SOP-FCH-19-02 (CIPAC MT 184, 184.1)","search_en":"Plant protection products Determination of suspensibility of formulations forming suspensions on dilution with water by LC/UV method SOP-FCH-19-02 (CIPAC MT 184, 184.1)","search_zh":"植物保护产品 LC/UV法测定兑水稀释后形成悬浮液制剂的悬浮率 SOP-FCH-19-02 (CIPAC MT 184, 184.1)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":249,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6ea79b081e6b3157f1ef1022","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"29","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie samorzutności dyspergowania koncentratów zawiesinowych metodą GC/FID","methodology_en":"Determination of spontaneity of dispersion of suspension concentrates by GC/FID method","methodology_zh":"GC/FID法测定悬浮剂的自发分散性","methodology_cs":"Stanovení samovolnosti dispergace suspenzních koncentrátů metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie samorzutności dyspergowania koncentratów zawiesinowych metodą GC/FID","reference":"SOP-FCH-19-03 (CIPAC MT 160)","norm_bases":["SOP-FCH-19-03","CIPAC MT 160"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: 2,4-D EHE, aclonifen, ametryn, azoxystrobin, bixafen, clomazone, cyflufenamid, cypermethrin, cyproconazole, deltamethrin, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimoxystrobin, epoxiconazole, ethofumesate, fenhexamid, fludioxonil, flurochloridone, fluroxypyr-meptyl, lambda-cyhalothrin, metalaxyl-M, metamitron, metazachlor, metconazole, metolachlor, metribuzin, myclobutanil, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, piperonyl butoxide, pirimiphos-methyl, propiconazole, prosulfocarb, pyraclostrobin, pyraflufen-ethyl, quizalofop-P-ethyl, silthiofam, spiroxamine, tebuconazole, terbuthylazine, thiabendazole, trifloxystrobin, trifluralin, trinexapac-ethyl, zoxamide","note_en":"Determined analytes: 2,4-D EHE, aclonifen, ametryn, azoxystrobin, bixafen, clomazone, cyflufenamid, cypermethrin, cyproconazole, deltamethrin, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimoxystrobin, epoxiconazole, ethofumesate, fenhexamid, fludioxonil, flurochloridone, fluroxypyr-meptyl, lambda-cyhalothrin, metalaxyl-M, metamitron, metazachlor, metconazole, metolachlor, metribuzin, myclobutanil, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, piperonyl butoxide, pirimiphos-methyl, propiconazole, prosulfocarb, pyraclostrobin, pyraflufen-ethyl, quizalofop-P-ethyl, silthiofam, spiroxamine, tebuconazole, terbuthylazine, thiabendazole, trifloxystrobin, trifluralin, trinexapac-ethyl, zoxamide","note_zh":"测定分析物：2,4-D EHE, aclonifen, ametryn, azoxystrobin, bixafen, clomazone, cyflufenamid, cypermethrin, cyproconazole, deltamethrin, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimoxystrobin, epoxiconazole, ethofumesate, fenhexamid, fludioxonil, flurochloridone, fluroxypyr-meptyl, lambda-cyhalothrin, metalaxyl-M, metamitron, metazachlor, metconazole, metolachlor, metribuzin, myclobutanil, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, piperonyl butoxide, pirimiphos-methyl, propiconazole, prosulfocarb, pyraclostrobin, pyraflufen-ethyl, quizalofop-P-ethyl, silthiofam, spiroxamine, tebuconazole, terbuthylazine, thiabendazole, trifloxystrobin, trifluralin, trinexapac-ethyl, zoxamide","note_cs":"Stanovované analyty: 2,4-D EHE, aclonifen, ametryn, azoxystrobin, bixafen, clomazone, cyflufenamid, cypermethrin, cyproconazole, deltamethrin, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimoxystrobin, epoxiconazole, ethofumesate, fenhexamid, fludioxonil, flurochloridon, fluroxypyr-meptyl, lambda-cyhalothrin, metalaxyl-M, metamitron, metazachlor, metconazole, metolachlor, metribuzin, myclobutanil, napropamid, paclobutrazol, pendimethalin, permethrin, pethoxamid, piperonyl butoxide, pirimiphos-methyl, propiconazole, prosulfocarb, pyraclostrobin, pyraflufen-ethyl, quizalofop-P-ethyl, silthiofam, spiroxamin, tebuconazole, terbuthylazin, thiabendazole, trifloxystrobin, trifluralin, trinexapac-ethyl, zoxamide","search_text":"Środki ochrony roślin Oznaczanie samorzutności dyspergowania koncentratów zawiesinowych metodą GC/FID Přípravky na ochranu rostlin Stanovení samovolnosti dispergace suspenzních koncentrátů metodou GC/FID SOP-FCH-19-03 (CIPAC MT 160) Srodki ochrony roslin Oznaczanie samorzutnosci dyspergowania koncentratow zawiesinowych metoda GC/FID Pripravky na ochranu rostlin Stanoveni samovolnosti dispergace suspenznich koncentratu metodou GC/FID SOP-FCH-19-03 (CIPAC MT 160)","search_en":"Plant protection products Determination of spontaneity of dispersion of suspension concentrates by GC/FID method SOP-FCH-19-03 (CIPAC MT 160)","search_zh":"植物保护产品 GC/FID法测定悬浮剂的自发分散性 SOP-FCH-19-03 (CIPAC MT 160)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":250,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e6d5997aa0ac797d8c99931a","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"30","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie samorzutności dyspergowania koncentratów zawiesinowych metodą LC/UV","methodology_en":"Determination of spontaneity of dispersion of suspension concentrates by LC/UV method","methodology_zh":"LC/UV法测定悬浮剂的自发分散性","methodology_cs":"Stanovení samovolnosti dispergace suspenzních koncentrátů metodou LC/UV","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie samorzutności dyspergowania koncentratów zawiesinowych metodą LC/UV","reference":"SOP-FCH-19-03 (CIPAC MT 160)","norm_bases":["SOP-FCH-19-03","CIPAC MT 160"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: 2,4-D, acetamiprid, ametoctradin, aclonifen, azoxystrobin, bentazone, boscalid, captan, clomazone, cloquintocet-mexyl, cymoxanil, cypermethrin, cyproconazole, cyprodinil, deltamethrin, dicamba, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimethomorph, dimoxystrobin, dithianon, epoxiconazole, fenhexamid, fipronil, florasulam, fludioxonil, flufenacet, flumioxazin, fluroxypyr-meptyl, flurprimidol, folpet, gibberellin, hexythiazox, chlortoluron, imazamox, imidacloprid, isofetamid, isoxaben, cyazofamid, lambda-cyhalothrin, mandipropamid, mecoprop-P, mefentrifluconazole, metamitron, metazachlor, metconazole, metrafenone, metribuzin, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, phenmedipham, picloram, pinoxaden, prosulfocarb, prothioconazole, pyraclostrobin, pyridate, quizalofop-p-ethyl, sedaxane, silthiofam, s-metolachlor, spinetoram, spinosad, spirotetramat, tau-fluvalinate, tebuconazole, tefluthrin, terbuthylazine, thiacloprid, thiamethoxam, thiophanate-methyl, triclopyr, trifloxystrobin, trifluralin, triflusulfuron-methyl, trinexapac-ethyl, triticonazole, zoxamide","note_en":"Determined analytes: 2,4-D, acetamiprid, ametoctradin, aclonifen, azoxystrobin, bentazone, boscalid, captan, clomazone, cloquintocet-mexyl, cymoxanil, cypermethrin, cyproconazole, cyprodinil, deltamethrin, dicamba, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimethomorph, dimoxystrobin, dithianon, epoxiconazole, fenhexamid, fipronil, florasulam, fludioxonil, flufenacet, flumioxazin, fluroxypyr-meptyl, flurprimidol, folpet, gibberellin, hexythiazox, chlortoluron, imazamox, imidacloprid, isofetamid, isoxaben, cyazofamid, lambda-cyhalothrin, mandipropamid, mecoprop-P, mefentrifluconazole, metamitron, metazachlor, metconazole, metrafenone, metribuzin, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, phenmedipham, picloram, pinoxaden, prosulfocarb, prothioconazole, pyraclostrobin, pyridate, quizalofop-p-ethyl, sedaxane, silthiofam, s-metolachlor, spinetoram, spinosad, spirotetramat, tau-fluvalinate, tebuconazole, tefluthrin, terbuthylazine, thiacloprid, thiamethoxam, thiophanate-methyl, triclopyr, trifloxystrobin, trifluralin, triflusulfuron-methyl, trinexapac-ethyl, triticonazole, zoxamide","note_zh":"测定分析物：2,4-D, acetamiprid, ametoctradin, aclonifen, azoxystrobin, bentazone, boscalid, captan, clomazone, cloquintocet-mexyl, cymoxanil, cypermethrin, cyproconazole, cyprodinil, deltamethrin, dicamba, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimethomorph, dimoxystrobin, dithianon, epoxiconazole, fenhexamid, fipronil, florasulam, fludioxonil, flufenacet, flumioxazin, fluroxypyr-meptyl, flurprimidol, folpet, gibberellin, hexythiazox, chlortoluron, imazamox, imidacloprid, isofetamid, isoxaben, cyazofamid, lambda-cyhalothrin, mandipropamid, mecoprop-P, mefentrifluconazole, metamitron, metazachlor, metconazole, metrafenone, metribuzin, napropamide, paclobutrazol, pendimethalin, permethrin, pethoxamid, phenmedipham, picloram, pinoxaden, prosulfocarb, prothioconazole, pyraclostrobin, pyridate, quizalofop-p-ethyl, sedaxane, silthiofam, s-metolachlor, spinetoram, spinosad, spirotetramat, tau-fluvalinate, tebuconazole, tefluthrin, terbuthylazine, thiacloprid, thiamethoxam, thiophanate-methyl, triclopyr, trifloxystrobin, trifluralin, triflusulfuron-methyl, trinexapac-ethyl, triticonazole, zoxamide","note_cs":"Stanovované analyty: 2,4-D, acetamiprid, ametoktradin, aclonifen, azoxystrobin, bentazone, boscalid, captan, clomazone, cloquintocet-mexyl, cymoxanil, cypermethrin, cyproconazole, cyprodinil, deltamethrin, dicamba, difenoconazole, diflufenican, dimethachlor, dimethenamid-P, dimethomorph, dimoxystrobin, dithianon, epoxiconazole, fenhexamid, fipronil, florasulam, fludioxonil, flufenacet, flumioxazin, fluroxypyr-meptyl, flurprimidol, folpet, giberelin, hexythiazox, chlortoluron, imazamox, imidacloprid, isofetamid, isoxaben, kyazofamid, lambda-cyhalothrin, mandipropamid, mecoprop-P, mefentrifluconazole, metamitron, metazachlor, metconazole, metrafenon, metribuzin, napropamid, paclobutrazol, pendimethalin, permethrin, pethoxamid, phenmedipham, picloram, pinoxaden, prosulfocarb, prothioconazole, pyraclostrobin, pyridate, quizalofop-p-ethyl, sedaxane, silthiofam, s-metolachlor, spinetoram, spinosad, spirotetramat, tau-fluvalinat, tebuconazole, tefluthrin, terbuthylazine, thiacloprid, thimethoxam, thiophanate-methyl, triclopyr, trifloxystrobin, trifluralin, triflusulfuron-methyl, trinexapac-ethyl, triticonazole, zoxamide","search_text":"Środki ochrony roślin Oznaczanie samorzutności dyspergowania koncentratów zawiesinowych metodą LC/UV Přípravky na ochranu rostlin Stanovení samovolnosti dispergace suspenzních koncentrátů metodou LC/UV SOP-FCH-19-03 (CIPAC MT 160) Srodki ochrony roslin Oznaczanie samorzutnosci dyspergowania koncentratow zawiesinowych metoda LC/UV Pripravky na ochranu rostlin Stanoveni samovolnosti dispergace suspenznich koncentratu metodou LC/UV SOP-FCH-19-03 (CIPAC MT 160)","search_en":"Plant protection products Determination of spontaneity of dispersion of suspension concentrates by LC/UV method SOP-FCH-19-03 (CIPAC MT 160)","search_zh":"植物保护产品 LC/UV法测定悬浮剂的自发分散性 SOP-FCH-19-03 (CIPAC MT 160)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":251,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"41950a7d600803f218b0dac8","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"31","test_object":"Środki ochrony roślin – formulacje ciekłe","test_object_en":"Plant protection products – liquid formulations","test_object_zh":"植物保护产品——液体制剂","test_object_cs":"Přípravky na ochranu rostlin – kapalné formulace","methodology":"Oznaczanie gęstości metodą piknometryczną","methodology_en":"Determination of density by pycnometric method","methodology_zh":"比重瓶法测定密度","methodology_cs":"Stanovení hustoty pyknometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości metodą piknometryczną","reference":"SOP-FCH-23-01 (CIPAC MT 3.2.1)","norm_bases":["SOP-FCH-23-01","CIPAC MT 3.2.1"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin – formulacje ciekłe Oznaczanie gęstości metodą piknometryczną Přípravky na ochranu rostlin – kapalné formulace Stanovení hustoty pyknometricky SOP-FCH-23-01 (CIPAC MT 3.2.1) Srodki ochrony roslin – formulacje ciekle Oznaczanie gestosci metoda piknometryczna Pripravky na ochranu rostlin – kapalne formulace Stanoveni hustoty pyknometricky SOP-FCH-23-01 (CIPAC MT 3.2.1)","search_en":"Plant protection products – liquid formulations Determination of density by pycnometric method SOP-FCH-23-01 (CIPAC MT 3.2.1)","search_zh":"植物保护产品——液体制剂 比重瓶法测定密度 SOP-FCH-23-01 (CIPAC MT 3.2.1)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":252,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f9c8344c37a7be25ff7e724e","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"32","test_object":"Środki ochrony roślin – formulacje ciekłe","test_object_en":"Plant protection products – liquid formulations","test_object_zh":"植物保护产品——液体制剂","test_object_cs":"Přípravky na ochranu rostlin – kapalné formulace","methodology":"Oznaczanie gęstości metodą kolby","methodology_en":"Determination of density by bottle method","methodology_zh":"瓶法测定密度","methodology_cs":"Stanovení hustoty baňkovou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości metodą kolby","reference":"SOP-FCH-21-01 (CIPAC MT 3.3.2)","norm_bases":["SOP-FCH-21-01","CIPAC MT 3.3.2"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środki ochrony roślin – formulacje ciekłe Oznaczanie gęstości metodą kolby Přípravky na ochranu rostlin – kapalné formulace Stanovení hustoty baňkovou metodou SOP-FCH-21-01 (CIPAC MT 3.3.2) Srodki ochrony roslin – formulacje ciekle Oznaczanie gestosci metoda kolby Pripravky na ochranu rostlin – kapalne formulace Stanoveni hustoty bankovou metodou SOP-FCH-21-01 (CIPAC MT 3.3.2)","search_en":"Plant protection products – liquid formulations Determination of density by bottle method SOP-FCH-21-01 (CIPAC MT 3.3.2)","search_zh":"植物保护产品——液体制剂 瓶法测定密度 SOP-FCH-21-01 (CIPAC MT 3.3.2)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":253,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d826f9a0eecf8b872da5513f","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"33","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie składników formulacji i zanieczyszczeń w ŚOR metodą GC/FID","methodology_en":"Determination of formulation additives and impurities in PPP by GC/FID method","methodology_zh":"GC/FID法测定植保产品中的助剂和杂质","methodology_cs":"Stanovení formulačních přísad a nečistot v POR metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie składników formulacji i zanieczyszczeń w ŚOR metodą GC/FID","reference":"SOP-CH-22-01","norm_bases":["SOP-CH-22-01"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: 1-butanol, 1-metylo-2-pirolidon, 1-oktanol, 1-pentanol, 2-etylo-1-heksanol, S-mleczan 2-etyloheksylu, 2-metylo-1-butanol, acetofenon, alkohol benzylowy, benzoesan benzylu, butylowany hydroksytoluen, cykloheksanon, kumen, alkohol diacetonowy, eter monometylowy glikolu dipropylenowego, gamma-butyrolakton, mirystynian izopropylu, oktanian metylu, N,N-dimetylodekanamid, N,N-dimetylolaktamid, N-oktylo-2-pirolidon, S-mleczan n-propylu, fenetol, węglan propylenu, fosforan tris(2-etyloheksylu)","note_en":"Determined analytes: 1-butanol, 1-methyl-2-pyrrolidone, 1-octanol, 1-pentanol, 2-ethyl-1-hexanol, 2-ethylhexyl-S-lactate, 2-methyl-1-butanol, acetophenone, benzyl alcohol, benzyl benzoate, butylated hydroxytoluene, cyclohexanone, cumene, diacetone alcohol, dipropylene glycol monomethyl ether, gamma-butyrolactone, isopropyl myristate, methyl octanoate, N,N-dimethyldecanamide, N,N-dimethyllactamide, N-octyl-2-pyrrolidone, n-propyl-S-lactate, phenetole, propylene carbonate, tris-2-ethylhexylphosphate","note_zh":"测定分析物：1-butanol, 1-methyl-2-pyrrolidone, 1-octanol, 1-pentanol, 2-ethyl-1-hexanol, 2-ethylhexyl-S-lactate, 2-methyl-1-butanol, acetophenone, benzyl alcohol, benzyl benzoate, butylated hydroxytoluene, cyclohexanone, cumene, diacetone alcohol, dipropylene glycol monomethyl ether, gamma-butyrolactone, isopropyl myristate, methyl octanoate, N,N-dimethyldecanamide, N,N-dimethyllactamide, N-octyl-2-pyrrolidone, n-propyl-S-lactate, phenetole, propylene carbonate, tris-2-ethylhexylphosphate","note_cs":"Stanovované analyty: 1-butanol, 1-methyl-2-pyrrolidone, 1-octanol, 1-pentanol, 2-ethyl-1-hexanol, 2-ethylhexyl-S-lactate, 2-methyl-1-butanol, acetophenone, benzyl alcohol, benzyl benzoate, butylovaný hydroxytoluen, cyklohexanone, cumene, diaceton alcohol, dipropropylenglykol monomethylether, gamma-butyrolactone, isopropyl myristate, methyl octanoate, N,N-dimethyldecanamide, N,N-dimethyllactamide, N-octyl-2-pyrrolidone, n-propyl-S-lactate, phenetole, propylene carbonate, tris-2-ethylhexylphosphate","search_text":"Środki ochrony roślin Oznaczanie składników formulacji i zanieczyszczeń w ŚOR metodą GC/FID Přípravky na ochranu rostlin Stanovení formulačních přísad a nečistot v POR metodou GC/FID SOP-CH-22-01 Srodki ochrony roslin Oznaczanie skladnikow formulacji i zanieczyszczen w SOR metoda GC/FID Pripravky na ochranu rostlin Stanoveni formulacnich prisad a necistot v POR metodou GC/FID SOP-CH-22-01","search_en":"Plant protection products Determination of formulation additives and impurities in PPP by GC/FID method SOP-CH-22-01","search_zh":"植物保护产品 GC/FID法测定植保产品中的助剂和杂质 SOP-CH-22-01","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":254,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"058f9cc345aab7744f676f03","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"34","test_object":"Środki ochrony roślin","test_object_en":"Plant protection products","test_object_zh":"植物保护产品","test_object_cs":"Přípravky na ochranu rostlin","methodology":"Oznaczanie składników formulacji i zanieczyszczeń w ŚOR metodą LC/MS","methodology_en":"Determination of formulation additives and impurities in PPP by LC/MS method","methodology_zh":"LC/MS法测定植保产品中的助剂和杂质","methodology_cs":"Stanovení formulačních přísad a nečistot v POR metodou LC/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie składników formulacji i zanieczyszczeń w ŚOR metodą LC/MS","reference":"SOP-CH-23-01","norm_bases":["SOP-CH-23-01"],"lab_section":"ÚKZÚZ, NRL, Dział Badań Środków Ochrony Roślin","lab_section_en":"ÚKZÚZ, NRL, Department of Testing Plant Protection Products","lab_section_zh":"ÚKZÚZ, NRL，植物保护产品检测科","lab_section_cs":"ÚKZÚZ, NRL, Oddělení zkoušení přípravků na ochranu rostlin","lab_address":"Zemědělská 1a, 613 00 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: 1,2,4-(1H)-triazol, 1,2-benzizotiazol-3-on, 2-metylo-4-izotiazolin-3-on, 5-chloro-2-metylo-2H-izotiazolin-3-on, izomer Z azoksystrobiny, 2,4-difluoroanilina (2,4-DFA), atrazyna, propazyna, symazyna","note_en":"Determined analytes: 1,2,4-(1H)-triazole, 1,2-benzisothiazol-3-one, 2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-2H-isothiazolin-3-one, Z-isomer of azoxystrobin, 2,4-difluoroaniline (2,4-DFA), atrazine, propazine, simazine","note_zh":"测定分析物：1,2,4-(1H)-triazole, 1,2-benzisothiazol-3-one, 2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-2H-isothiazolin-3-one, Z-isomer of azoxystrobin, 2,4-difluoroaniline (2,4-DFA), atrazine, propazine, simazine","note_cs":"Stanovované analyty: 1,2,4-(1H)-triazole, 1,2-benzisothiazol-3-one, 2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-2h-isothiazolin-3-one, Z-isomer azoxystrobin, 2,4-difluoroanilin (2,4-DFA), atrazin, propazin, simazin","search_text":"Środki ochrony roślin Oznaczanie składników formulacji i zanieczyszczeń w ŚOR metodą LC/MS Přípravky na ochranu rostlin Stanovení formulačních přísad a nečistot v POR metodou LC/MS SOP-CH-23-01 Srodki ochrony roslin Oznaczanie skladnikow formulacji i zanieczyszczen w SOR metoda LC/MS Pripravky na ochranu rostlin Stanoveni formulacnich prisad a necistot v POR metodou LC/MS SOP-CH-23-01","search_en":"Plant protection products Determination of formulation additives and impurities in PPP by LC/MS method SOP-CH-23-01","search_zh":"植物保护产品 LC/MS法测定植保产品中的助剂和杂质 SOP-CH-23-01","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":255,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"823b244f70a3eec956a98c5e","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"1","test_object":"Materiał roślinny, wody do nawadniania i ścieki, kultury bakteryjne","test_object_en":"Plant material, irrigation and wastewater, bacterial cultures","test_object_zh":"植物材料、灌溉水和废水、细菌培养物","test_object_cs":"Rostlinný materiál, závlahové a odpadní vody, bakteriální kultury","methodology":"Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum metodą mikroskopii świetlnej","methodology_en":"Detection and identification of Clavibacter sepedonicus and Ralstonia solanacearum by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定Clavibacter sepedonicus和Ralstonia solanacearum","methodology_cs":"Detekce a identifikace Clavibacter sepedonicus a Ralstonia solanacearum metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum metodą mikroskopii świetlnej","reference":"SOP-M-02, mimo kap. 3.3, 3.4, 3.5 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194)","norm_bases":["SOP-M-02","PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Havlíčkův Brod","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Havlíčkův Brod","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，哈夫利奇库夫布罗德植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Havlíčkův Brod","lab_address":"Konečná 1930, 580 01 Havlíčkův Brod","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":"Literatura źródłowa: Rozporządzenie wykonawcze Komisji (UE) 2022/1194 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018 oraz Rozporządzenie wykonawcze Komisji (UE) 2022/1193 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Ralstonia solanacearum (Smith 1896) Yabuuchi et al. 1996 emend. Safni et al. 2014. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: Commission Implementing Regulation (EU) 2022/1194 of 11 July 2022 establishing measures to eradicate and prevent the spread of Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018 and Commission Implementing Regulation (EU) 2022/1193 of 11 July 2022 establishing measures to eradicate and prevent the spread of Ralstonia solanacearum (Smith 1896) Yabuuchi et al. 1996 emend. Safni et al. 2014. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：2022年7月11日委员会实施条例（EU）2022/1194，规定根除和防止Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018传播的措施；以及2022年7月11日委员会实施条例（EU）2022/1193，规定根除和防止Ralstonia solanacearum (Smith 1896) Yabuuchi et al. 1996 emend. Safni et al. 2014传播的措施。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1194 ze dne 11. července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismu Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018 a PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 ze dne 11.července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismu Ralstonia solanacearum (Smith 1896) Yabuuchi et al.1996 emend.Safni et al.2014). Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, wody do nawadniania i ścieki, kultury bakteryjne Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum metodą mikroskopii świetlnej Rostlinný materiál, závlahové a odpadní vody, bakteriální kultury Detekce a identifikace Clavibacter sepedonicus a Ralstonia solanacearum metodou světelné mikroskopie SOP-M-02, mimo kap. 3.3, 3.4, 3.5 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194) Material roslinny, wody do nawadniania i scieki, kultury bakteryjne Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum metoda mikroskopii swietlnej Rostlinny material, zavlahove a odpadni vody, bakterialni kultury Detekce a identifikace Clavibacter sepedonicus a Ralstonia solanacearum metodou svetelne mikroskopie SOP-M-02, mimo kap. 3.3, 3.4, 3.5 (PROVADECI NARIZENI KOMISE (EU) 2022/1193 a 2022/1194)","search_en":"Plant material, irrigation and wastewater, bacterial cultures Detection and identification of Clavibacter sepedonicus and Ralstonia solanacearum by light microscopy method SOP-M-02, mimo kap. 3.3, 3.4, 3.5 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194)","search_zh":"植物材料、灌溉水和废水、细菌培养物 光学显微镜法检测和鉴定Clavibacter sepedonicus和Ralstonia solanacearum SOP-M-02, mimo kap. 3.3, 3.4, 3.5 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194)","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":256,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f0680098ba0519bf0821acc5","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"2","test_object":"Materiał roślinny, wody do nawadniania i ścieki, kultury bakteryjne","test_object_en":"Plant material, irrigation and wastewater, bacterial cultures","test_object_zh":"植物材料、灌溉水和废水、细菌培养物","test_object_cs":"Rostlinný materiál, závlahové a odpadní vody, bakteriální kultury","methodology":"Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum metodą real-time PCR","methodology_en":"Detection and identification of Clavibacter sepedonicus and Ralstonia solanacearum by real-time PCR method","methodology_zh":"实时荧光PCR法检测和鉴定Clavibacter sepedonicus和Ralstonia solanacearum","methodology_cs":"Detekce a identifikace Clavibacter sepedonicus a Ralstonia solanacearum metodou real-time PCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum metodą real-time PCR","reference":"SOP-M-02, mimo kap. 3.2, 3.4, 3.5 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194)","norm_bases":["SOP-M-02","PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Havlíčkův Brod","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Havlíčkův Brod","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，哈夫利奇库夫布罗德植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Havlíčkův Brod","lab_address":"Konečná 1930, 580 01 Havlíčkův Brod","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":"Literatura źródłowa: Rozporządzenie wykonawcze Komisji (UE) 2022/1194 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018 oraz Rozporządzenie wykonawcze Komisji (UE) 2022/1193 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Ralstonia solanacearum (Smith 1896) Yabuuchi et al. 1996 emend. Safni et al. 2014. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: Commission Implementing Regulation (EU) 2022/1194 of 11 July 2022 establishing measures to eradicate and prevent the spread of Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018 and Commission Implementing Regulation (EU) 2022/1193 of 11 July 2022 establishing measures to eradicate and prevent the spread of Ralstonia solanacearum (Smith 1896) Yabuuchi et al. 1996 emend. Safni et al. 2014. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：2022年7月11日委员会实施条例（EU）2022/1194，规定根除和防止Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018传播的措施；以及2022年7月11日委员会实施条例（EU）2022/1193，规定根除和防止Ralstonia solanacearum (Smith 1896) Yabuuchi et al. 1996 emend. Safni et al. 2014传播的措施。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1194 ze dne 11. července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismu Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018 a PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 ze dne 11.července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismu Ralstonia solanacearum (Smith 1896) Yabuuchi et al.1996 emend.Safni et al.2014). Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, wody do nawadniania i ścieki, kultury bakteryjne Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum metodą real-time PCR Rostlinný materiál, závlahové a odpadní vody, bakteriální kultury Detekce a identifikace Clavibacter sepedonicus a Ralstonia solanacearum metodou real-time PCR SOP-M-02, mimo kap. 3.2, 3.4, 3.5 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194) Material roslinny, wody do nawadniania i scieki, kultury bakteryjne Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum metoda real-time PCR Rostlinny material, zavlahove a odpadni vody, bakterialni kultury Detekce a identifikace Clavibacter sepedonicus a Ralstonia solanacearum metodou real-time PCR SOP-M-02, mimo kap. 3.2, 3.4, 3.5 (PROVADECI NARIZENI KOMISE (EU) 2022/1193 a 2022/1194)","search_en":"Plant material, irrigation and wastewater, bacterial cultures Detection and identification of Clavibacter sepedonicus and Ralstonia solanacearum by real-time PCR method SOP-M-02, mimo kap. 3.2, 3.4, 3.5 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194)","search_zh":"植物材料、灌溉水和废水、细菌培养物 实时荧光PCR法检测和鉴定Clavibacter sepedonicus和Ralstonia solanacearum SOP-M-02, mimo kap. 3.2, 3.4, 3.5 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194)","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":257,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d3939d02d2fdcdf4280d4629","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"3","test_object":"Materiał roślinny, wody do nawadniania i ścieki, kultury bakteryjne","test_object_en":"Plant material, irrigation and wastewater, bacterial cultures","test_object_zh":"植物材料、灌溉水和废水、细菌培养物","test_object_cs":"Rostlinný materiál, závlahové a odpadní vody, bakteriální kultury","methodology":"Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum metodą hodowlaną","methodology_en":"Detection and identification of Clavibacter sepedonicus and Ralstonia solanacearum by cultivation method","methodology_zh":"培养法检测和鉴定Clavibacter sepedonicus和Ralstonia solanacearum","methodology_cs":"Detekce a identifikace Clavibacter sepedonicus a Ralstonia solanacearum metodou kultivace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum metodą hodowlaną","reference":"SOP-M-02, mimo kap. 3.2, 3.3, 3.4 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194)","norm_bases":["SOP-M-02","PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Havlíčkův Brod","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Havlíčkův Brod","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，哈夫利奇库夫布罗德植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Havlíčkův Brod","lab_address":"Konečná 1930, 580 01 Havlíčkův Brod","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":"Literatura źródłowa: Rozporządzenie wykonawcze Komisji (UE) 2022/1194 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018 oraz Rozporządzenie wykonawcze Komisji (UE) 2022/1193 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Ralstonia solanacearum (Smith 1896) Yabuuchi et al. 1996 emend. Safni et al. 2014. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: Commission Implementing Regulation (EU) 2022/1194 of 11 July 2022 establishing measures to eradicate and prevent the spread of Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018 and Commission Implementing Regulation (EU) 2022/1193 of 11 July 2022 establishing measures to eradicate and prevent the spread of Ralstonia solanacearum (Smith 1896) Yabuuchi et al. 1996 emend. Safni et al. 2014. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：2022年7月11日委员会实施条例（EU）2022/1194，规定根除和防止Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018传播的措施；以及2022年7月11日委员会实施条例（EU）2022/1193，规定根除和防止Ralstonia solanacearum (Smith 1896) Yabuuchi et al. 1996 emend. Safni et al. 2014传播的措施。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1194 ze dne 11. července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismu Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018 a PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 ze dne 11.července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismu Ralstonia solanacearum (Smith 1896) Yabuuchi et al.1996 emend.Safni et al.2014). Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, wody do nawadniania i ścieki, kultury bakteryjne Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum metodą hodowlaną Rostlinný materiál, závlahové a odpadní vody, bakteriální kultury Detekce a identifikace Clavibacter sepedonicus a Ralstonia solanacearum metodou kultivace SOP-M-02, mimo kap. 3.2, 3.3, 3.4 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194) Material roslinny, wody do nawadniania i scieki, kultury bakteryjne Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum metoda hodowlana Rostlinny material, zavlahove a odpadni vody, bakterialni kultury Detekce a identifikace Clavibacter sepedonicus a Ralstonia solanacearum metodou kultivace SOP-M-02, mimo kap. 3.2, 3.3, 3.4 (PROVADECI NARIZENI KOMISE (EU) 2022/1193 a 2022/1194)","search_en":"Plant material, irrigation and wastewater, bacterial cultures Detection and identification of Clavibacter sepedonicus and Ralstonia solanacearum by cultivation method SOP-M-02, mimo kap. 3.2, 3.3, 3.4 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194)","search_zh":"植物材料、灌溉水和废水、细菌培养物 培养法检测和鉴定Clavibacter sepedonicus和Ralstonia solanacearum SOP-M-02, mimo kap. 3.2, 3.3, 3.4 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194)","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":258,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1e7b2912193501bc444f5019","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"4","test_object":"Materiał roślinny, wody do nawadniania i ścieki, kultury bakteryjne","test_object_en":"Plant material, irrigation and wastewater, bacterial cultures","test_object_zh":"植物材料、灌溉水和废水、细菌培养物","test_object_cs":"Rostlinný materiál, závlahové a odpadní vody, bakteriální kultury","methodology":"Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum testem biologicznym","methodology_en":"Detection and identification of Clavibacter sepedonicus and Ralstonia solanacearum by biological test","methodology_zh":"生物测定法检测和鉴定Clavibacter sepedonicus和Ralstonia solanacearum","methodology_cs":"Detekce a identifikace Clavibacter sepedonicus a Ralstonia solanacearum biologickým testem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum testem biologicznym","reference":"SOP-M-02, mimo kap. 3.2, 3.3, 3.5 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194)","norm_bases":["SOP-M-02","PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Havlíčkův Brod","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Havlíčkův Brod","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，哈夫利奇库夫布罗德植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Havlíčkův Brod","lab_address":"Konečná 1930, 580 01 Havlíčkův Brod","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":"Literatura źródłowa: Rozporządzenie wykonawcze Komisji (UE) 2022/1194 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018 oraz Rozporządzenie wykonawcze Komisji (UE) 2022/1193 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Ralstonia solanacearum (Smith 1896) Yabuuchi et al. 1996 emend. Safni et al. 2014. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: Commission Implementing Regulation (EU) 2022/1194 of 11 July 2022 establishing measures to eradicate and prevent the spread of Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018 and Commission Implementing Regulation (EU) 2022/1193 of 11 July 2022 establishing measures to eradicate and prevent the spread of Ralstonia solanacearum (Smith 1896) Yabuuchi et al. 1996 emend. Safni et al. 2014. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：2022年7月11日委员会实施条例（EU）2022/1194，规定根除和防止Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018传播的措施；以及2022年7月11日委员会实施条例（EU）2022/1193，规定根除和防止Ralstonia solanacearum (Smith 1896) Yabuuchi et al. 1996 emend. Safni et al. 2014传播的措施。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1194 ze dne 11. července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismu Clavibacter sepedonicus (Spieckermann & Kotthoff 1914) Nouioui et al. 2018 a PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 ze dne 11.července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismu Ralstonia solanacearum (Smith 1896) Yabuuchi et al.1996 emend.Safni et al.2014). Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, wody do nawadniania i ścieki, kultury bakteryjne Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum testem biologicznym Rostlinný materiál, závlahové a odpadní vody, bakteriální kultury Detekce a identifikace Clavibacter sepedonicus a Ralstonia solanacearum biologickým testem SOP-M-02, mimo kap. 3.2, 3.3, 3.5 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194) Material roslinny, wody do nawadniania i scieki, kultury bakteryjne Wykrywanie i identyfikacja Clavibacter sepedonicus i Ralstonia solanacearum testem biologicznym Rostlinny material, zavlahove a odpadni vody, bakterialni kultury Detekce a identifikace Clavibacter sepedonicus a Ralstonia solanacearum biologickym testem SOP-M-02, mimo kap. 3.2, 3.3, 3.5 (PROVADECI NARIZENI KOMISE (EU) 2022/1193 a 2022/1194)","search_en":"Plant material, irrigation and wastewater, bacterial cultures Detection and identification of Clavibacter sepedonicus and Ralstonia solanacearum by biological test SOP-M-02, mimo kap. 3.2, 3.3, 3.5 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194)","search_zh":"植物材料、灌溉水和废水、细菌培养物 生物测定法检测和鉴定Clavibacter sepedonicus和Ralstonia solanacearum SOP-M-02, mimo kap. 3.2, 3.3, 3.5 (PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1193 a 2022/1194)","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":259,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5ee4a37ccb5c7c0f266a0620","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"5","test_object":"Materiał roślinny, materiał siewny","test_object_en":"Plant material, seed","test_object_zh":"植物材料、种子","test_object_cs":"Rostlinný materiál, osivo","methodology":"Wykrywanie i identyfikacja wybranych gatunków z rodzaju Tilletia metodą mikroskopii świetlnej","methodology_en":"Detection and identification of selected species of the genus Tilletia by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定腥黑粉菌属（Tilletia）选定种类","methodology_cs":"Detekce a identifikace vybraných druhů rodu Tilletia metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja wybranych gatunków z rodzaju Tilletia metodą mikroskopii świetlnej","reference":"SOP-M-44","norm_bases":["SOP-M-44"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Havlíčkův Brod","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Havlíčkův Brod","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，哈夫利奇库夫布罗德植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Havlíčkův Brod","lab_address":"Konečná 1930, 580 01 Havlíčkův Brod","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wykaz identyfikowanych gatunków z rodzaju Tilletia: Tilletia controversa, Tilletia tritici, Tilletia indica, Tilletia foetida Literatura źródłowa: Kochanová, M., Prokinová, E., Metody diagnostiky Tilletia spp. v teorii a praxi, 2004, ČFS. 68 s. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"List of identified species of the genus Tilletia: Tilletia controversa, Tilletia tritici, Tilletia indica, Tilletia foetida Source literature: Kochanová, M., Prokinová, E., Metody diagnostiky Tilletia spp. v teorii a praxi, 2004, ČFS. 68 p. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"鉴定的腥黑粉菌属（Tilletia）种类清单：Tilletia controversa, Tilletia tritici, Tilletia indica, Tilletia foetida参考文献：Kochanová, M., Prokinová, E., Metody diagnostiky Tilletia spp. v teorii a praxi, 2004, ČFS. 68页。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Seznam identifikovaných druhů z rodu Tilletia: Tilletia controversa, Tilletia tritici, Tilletia indica, Tilletia foetida Zdrojová literatura: Kochanová, M., Prokinová, E., Metody diagnostiky Tilletia spp. v teorii a praxi, 2004, ČFS. 68 p. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, materiał siewny Wykrywanie i identyfikacja wybranych gatunków z rodzaju Tilletia metodą mikroskopii świetlnej Rostlinný materiál, osivo Detekce a identifikace vybraných druhů rodu Tilletia metodou světelné mikroskopie SOP-M-44 Material roslinny, material siewny Wykrywanie i identyfikacja wybranych gatunkow z rodzaju Tilletia metoda mikroskopii swietlnej Rostlinny material, osivo Detekce a identifikace vybranych druhu rodu Tilletia metodou svetelne mikroskopie SOP-M-44","search_en":"Plant material, seed Detection and identification of selected species of the genus Tilletia by light microscopy method SOP-M-44","search_zh":"植物材料、种子 光学显微镜法检测和鉴定腥黑粉菌属（Tilletia）选定种类 SOP-M-44","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":260,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"74ad22f5f0053951d91c7cf9","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"6","test_object":"Materiał roślinny","test_object_en":"Plant material","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Jakościowe wykrywanie wirusów PLRV, PVY, PVA, PVM, PVX i PVS metodą real-time PCR","methodology_en":"Qualitative detection of PLRV, PVY, PVA, PVM, PVX and PVS viruses by real-time PCR method","methodology_zh":"实时荧光PCR法定性检测PLRV、PVY、PVA、PVM、PVX和PVS病毒","methodology_cs":"Kvalitativní detekce virů PLRV, PVY, PVA, PVM, PVX a PVS metodou real-time PCR","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Jakościowe wykrywanie wirusów PLRV, PVY, PVA, PVM, PVX i PVS metodą real-time PCR","reference":"SOP-M-49","norm_bases":["SOP-M-49"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Havlíčkův Brod","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Havlíčkův Brod","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，哈夫利奇库夫布罗德植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Havlíčkův Brod","lab_address":"Konečná 1930, 580 01 Havlíčkův Brod","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: Agindotan BO, Shiel PJ, Berger PH. Simultaneous detection of potato viruses, PLRV, PVA, PVX and PVY from dormant potato tubers by TaqMan real-time RT-PCR. J Virol Methods. 2007 Jun;142(1-2):1-9. doi: 10.1016/j.jviromet.2006.12.012. Epub 2007 Feb 5. PMID: 17276522. Mortimer-Jones SM, Jones MG, Jones RA, Thomson G, Dwyer GI. A single tube, quantitative real-time RT-PCR assay that detects four potato viruses simultaneously. J Virol Methods. 2009 Nov;161(2):289-96. doi: 10.1016/j.jviromet.2009.06.027. Epub 2009 Jul 9. PMID: 19596379. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: Agindotan BO, Shiel PJ, Berger PH. Simultaneous detection of potato viruses, PLRV, PVA, PVX and PVY from dormant potato tubers by TaqMan real-time RT-PCR. J Virol Methods. 2007 Jun;142(1-2):1-9. doi: 10.1016/j.jviromet.2006.12.012. Epub 2007 Feb 5. PMID: 17276522. Mortimer-Jones SM, Jones MG, Jones RA, Thomson G, Dwyer GI. A single tube, quantitative real-time RT-PCR assay that detects four potato viruses simultaneously. J Virol Methods. 2009 Nov;161(2):289-96. doi: 10.1016/j.jviromet.2009.06.027. Epub 2009 Jul 9. PMID: 19596379. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：Agindotan BO, Shiel PJ, Berger PH. Simultaneous detection of potato viruses, PLRV, PVA, PVX and PVY from dormant potato tubers by TaqMan real-time RT-PCR. J Virol Methods. 2007 Jun;142(1-2):1-9. doi: 10.1016/j.jviromet.2006.12.012. Epub 2007 Feb 5. PMID: 17276522.Mortimer-Jones SM, Jones MG, Jones RA, Thomson G, Dwyer GI. A single tube, quantitative real-time RT-PCR assay that detects four potato viruses simultaneously. J Virol Methods. 2009 Nov;161(2):289-96. doi: 10.1016/j.jviromet.2009.06.027. Epub 2009 Jul 9. PMID: 19596379.相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: Agindotan BO, Shiel PJ, Berger PH. Simultaneous detection of potato viruses, PLRV, PVA, PVX and PVY from dormant potato tubers by TaqMan real-time RT-PCR. J Virol Methods. 2007 Jun;142(1-2):1-9. doi: 10.1016/j.jviromet.2006.12.012. Epub 2007 Feb 5. PMID: 17276522. Mortimer-Jones SM, Jones MG, Jones RA, Thomson G, Dwyer GI. A single tube, quantitative real-time RT-PCR assay that detects four potato viruses simultaneously. J Virol Methods. 2009 Nov;161(2):289-96. doi: 10.1016/j.jviromet.2009.06.027. Epub 2009 Jul 9. PMID: 19596379. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny Jakościowe wykrywanie wirusów PLRV, PVY, PVA, PVM, PVX i PVS metodą real-time PCR Rostlinný materiál Kvalitativní detekce virů PLRV, PVY, PVA, PVM, PVX a PVS metodou real-time PCR SOP-M-49 Material roslinny Jakosciowe wykrywanie wirusow PLRV, PVY, PVA, PVM, PVX i PVS metoda real-time PCR Rostlinny material Kvalitativni detekce viru PLRV, PVY, PVA, PVM, PVX a PVS metodou real-time PCR SOP-M-49","search_en":"Plant material Qualitative detection of PLRV, PVY, PVA, PVM, PVX and PVS viruses by real-time PCR method SOP-M-49","search_zh":"植物材料 实时荧光PCR法定性检测PLRV、PVY、PVA、PVM、PVX和PVS病毒 SOP-M-49","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":261,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"03072cdf6de8edf7c418837d","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"7","test_object":"Materiał roślinny, materiał siewny","test_object_en":"Plant material, seed","test_object_zh":"植物材料、种子","test_object_cs":"Rostlinný materiál, osivo","methodology":"Wykrywanie wirusów roślin metodą DAS-ELISA","methodology_en":"Detection of plant viruses by DAS-ELISA method","methodology_zh":"DAS-ELISA法检测植物病毒","methodology_cs":"Detekce rostlinných virů metodou DAS-ELISA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie wirusów roślin metodą DAS-ELISA","reference":"SOP-M-51","norm_bases":["SOP-M-51"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Havlíčkův Brod","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Havlíčkův Brod","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，哈夫利奇库夫布罗德植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Havlíčkův Brod","lab_address":"Konečná 1930, 580 01 Havlíčkův Brod","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Wykaz badanych organizmów: zestawy ELISA do diagnostyki wirusów roślin producentów: Agdia, Bioreba, Creative Diagnostics, DSMZ, Loewe, Neogen, Sediag, Prime Diagnostics Literatura źródłowa: PM 7/125 ELISA tests for viruses. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"List of organisms tested: ELISA kits for the diagnostics of plant viruses from manufacturers: Agdia, Bioreba, Creative Diagnostics, DSMZ, Loewe, Neogen, Sediag, Prime Diagnostics Source literature: PM 7/125 ELISA tests for viruses. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"检测生物清单：以下生产商的植物病毒诊断ELISA试剂盒：Agdia, Bioreba, Creative Diagnostics, DSMZ, Loewe, Neogen, Sediag, Prime Diagnostics参考文献：PM 7/125 ELISA tests for viruses.相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Seznam testovaných organismů: ELISA kity pro diagnostiku rostlinných virů od výrobců: Agdia, Bioreba, Creative Diagnostics, DSMZ, Loewe, Neogen, Sediag, Prime Diagnostics Zdrojová literatura: PM 7/125 ELISA tests for viruses. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, materiał siewny Wykrywanie wirusów roślin metodą DAS-ELISA Rostlinný materiál, osivo Detekce rostlinných virů metodou DAS-ELISA SOP-M-51 Material roslinny, material siewny Wykrywanie wirusow roslin metoda DAS-ELISA Rostlinny material, osivo Detekce rostlinnych viru metodou DAS-ELISA SOP-M-51","search_en":"Plant material, seed Detection of plant viruses by DAS-ELISA method SOP-M-51","search_zh":"植物材料、种子 DAS-ELISA法检测植物病毒 SOP-M-51","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":262,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b0479b5adadfe038024d963d","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"8","test_object":"Gleba, podłoża, materiał roślinny","test_object_en":"Soil, substrates, plant material","test_object_zh":"土壤、基质、植物材料","test_object_cs":"Půda, substráty, rostlinný materiál","methodology":"Wykrywanie i identyfikacja przetrwalnikowych zoosporangiów sprawcy raka ziemniaka Synchytrium endobioticum metodą mikroskopii świetlnej","methodology_en":"Detection and identification of permanent zoosporangia of Synchytrium endobioticum, the causal agent of potato wart disease, by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定马铃薯癌肿病病原菌Synchytrium endobioticum的休眠孢子囊","methodology_cs":"Detekce a identifikace trvalých zoosporangií původce rakoviny bramboru Synchytrium endobioticum metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja przetrwalnikowych zoosporangiów sprawcy raka ziemniaka Synchytrium endobioticum metodą mikroskopii świetlnej","reference":"SOP-M-69, mimo kap. 7.1.4","norm_bases":["SOP-M-69"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Havlíčkův Brod","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Havlíčkův Brod","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，哈夫利奇库夫布罗德植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Havlíčkův Brod","lab_address":"Konečná 1930, 580 01 Havlíčkův Brod","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Literatura źródłowa: Karling J.S. (1964): Synchytrium. Academic press, 470p., EPPO PM 7/28 Synchytrium endobioticum. Rozporządzenie wykonawcze Komisji (UE) 2022/1195 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Synchytrium endobioticum (Schilbersky) Percival.","note_en":"Source literature: Karling J.S. (1964): Synchytrium. Academic press, 470p., EPPO PM 7/28 Synchytrium endobioticum. Commission Implementing Regulation (EU) 2022/1195 of 11 July 2022 establishing measures to eradicate and prevent the spread of Synchytrium endobioticum (Schilbersky) Percival.","note_zh":"参考文献：Karling J.S. (1964): Synchytrium. Academic press, 470p., EPPO PM 7/28 Synchytrium endobioticum.2022年7月11日委员会实施条例（EU）2022/1195，规定根除和防止Synchytrium endobioticum (Schilbersky) Percival传播的措施。","note_cs":"Zdrojová literatura: Karling J.S. (1964): Synchytrium. Academic press, 470p., EPPO PM 7/28 Synchytrium endobioticum. PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1195 ze dne 11.července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismu Synchytrium endobioticum (Schilbersky) Percival.","search_text":"Gleba, podłoża, materiał roślinny Wykrywanie i identyfikacja przetrwalnikowych zoosporangiów sprawcy raka ziemniaka Synchytrium endobioticum metodą mikroskopii świetlnej Půda, substráty, rostlinný materiál Detekce a identifikace trvalých zoosporangií původce rakoviny bramboru Synchytrium endobioticum metodou světelné mikroskopie SOP-M-69, mimo kap. 7.1.4 Gleba, podloza, material roslinny Wykrywanie i identyfikacja przetrwalnikowych zoosporangiow sprawcy raka ziemniaka Synchytrium endobioticum metoda mikroskopii swietlnej Puda, substraty, rostlinny material Detekce a identifikace trvalych zoosporangii puvodce rakoviny bramboru Synchytrium endobioticum metodou svetelne mikroskopie SOP-M-69, mimo kap. 7.1.4","search_en":"Soil, substrates, plant material Detection and identification of permanent zoosporangia of Synchytrium endobioticum, the causal agent of potato wart disease, by light microscopy method SOP-M-69, mimo kap. 7.1.4","search_zh":"土壤、基质、植物材料 光学显微镜法检测和鉴定马铃薯癌肿病病原菌Synchytrium endobioticum的休眠孢子囊 SOP-M-69, mimo kap. 7.1.4","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":263,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cecb7e7aab2ce70565047854","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"9","test_object":"Gleba, podłoża, materiał roślinny","test_object_en":"Soil, substrates, plant material","test_object_zh":"土壤、基质、植物材料","test_object_cs":"Půda, substráty, rostlinný materiál","methodology":"Wykrywanie i identyfikacja przetrwalnikowych zoosporangiów sprawcy raka ziemniaka Synchytrium endobioticum testem biologicznym","methodology_en":"Detection and identification of permanent zoosporangia of Synchytrium endobioticum, the causal agent of potato wart disease, by biological test","methodology_zh":"生物测定法检测和鉴定马铃薯癌肿病病原菌Synchytrium endobioticum的休眠孢子囊","methodology_cs":"Detekce a identifikace trvalých zoosporangií původce rakoviny bramboru Synchytrium endobioticum biologickým testem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja przetrwalnikowych zoosporangiów sprawcy raka ziemniaka Synchytrium endobioticum testem biologicznym","reference":"SOP-M-69, mimo kap. 7.1.3","norm_bases":["SOP-M-69"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Havlíčkův Brod","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Havlíčkův Brod","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，哈夫利奇库夫布罗德植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Havlíčkův Brod","lab_address":"Konečná 1930, 580 01 Havlíčkův Brod","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Literatura źródłowa: Karling J.S. (1964): Synchytrium. Academic press, 470p., EPPO PM 7/28 Synchytrium endobioticum. Rozporządzenie wykonawcze Komisji (UE) 2022/1195 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Synchytrium endobioticum (Schilbersky) Percival.","note_en":"Source literature: Karling J.S. (1964): Synchytrium. Academic press, 470p., EPPO PM 7/28 Synchytrium endobioticum. Commission Implementing Regulation (EU) 2022/1195 of 11 July 2022 establishing measures to eradicate and prevent the spread of Synchytrium endobioticum (Schilbersky) Percival.","note_zh":"参考文献：Karling J.S. (1964): Synchytrium. Academic press, 470p., EPPO PM 7/28 Synchytrium endobioticum.2022年7月11日委员会实施条例（EU）2022/1195，规定根除和防止Synchytrium endobioticum (Schilbersky) Percival传播的措施。","note_cs":"Zdrojová literatura: Karling J.S. (1964): Synchytrium. Academic press, 470p., EPPO PM 7/28 Synchytrium endobioticum. PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1195 ze dne 11.července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismu Synchytrium endobioticum (Schilbersky) Percival.","search_text":"Gleba, podłoża, materiał roślinny Wykrywanie i identyfikacja przetrwalnikowych zoosporangiów sprawcy raka ziemniaka Synchytrium endobioticum testem biologicznym Půda, substráty, rostlinný materiál Detekce a identifikace trvalých zoosporangií původce rakoviny bramboru Synchytrium endobioticum biologickým testem SOP-M-69, mimo kap. 7.1.3 Gleba, podloza, material roslinny Wykrywanie i identyfikacja przetrwalnikowych zoosporangiow sprawcy raka ziemniaka Synchytrium endobioticum testem biologicznym Puda, substraty, rostlinny material Detekce a identifikace trvalych zoosporangii puvodce rakoviny bramboru Synchytrium endobioticum biologickym testem SOP-M-69, mimo kap. 7.1.3","search_en":"Soil, substrates, plant material Detection and identification of permanent zoosporangia of Synchytrium endobioticum, the causal agent of potato wart disease, by biological test SOP-M-69, mimo kap. 7.1.3","search_zh":"土壤、基质、植物材料 生物测定法检测和鉴定马铃薯癌肿病病原菌Synchytrium endobioticum的休眠孢子囊 SOP-M-69, mimo kap. 7.1.3","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":264,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"85324cf8271d11cd751e0d23","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"10","test_object":"Materiał roślinny, drewno, materiał siewny, podłoża, gleba, owady, osady, nicienie","test_object_en":"Plant material, wood, seed, substrates, soil, insects, sludge, nematodes","test_object_zh":"植物材料、木材、种子、基质、土壤、昆虫、污泥、线虫","test_object_cs":"Rostlinný materiál, dřevo, osivo, substráty, půda, hmyz, kaly, hlístice","methodology":"Wykrywanie i identyfikacja nicieni fitofagicznych, mykofagicznych i wolno żyjących metodą mikroskopii świetlnej","methodology_en":"Detection and identification of phytophagous, mycophagous and free-living nematodes by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定植食性、食菌性和自由生活线虫","methodology_cs":"Detekce a identifikace fytofágních, mykofágních a volně žijících hlístic metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja nicieni fitofagicznych, mykofagicznych i wolno żyjących metodą mikroskopii świetlnej","reference":"SOP-M-81","norm_bases":["SOP-M-81"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Havlíčkův Brod","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Havlíčkův Brod","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，哈夫利奇库夫布罗德植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Havlíčkův Brod","lab_address":"Konečná 1930, 580 01 Havlíčkův Brod","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"Source literature: Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"参考文献：Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp.相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Zdrojová literatura: Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, drewno, materiał siewny, podłoża, gleba, owady, osady, nicienie Wykrywanie i identyfikacja nicieni fitofagicznych, mykofagicznych i wolno żyjących metodą mikroskopii świetlnej Rostlinný materiál, dřevo, osivo, substráty, půda, hmyz, kaly, hlístice Detekce a identifikace fytofágních, mykofágních a volně žijících hlístic metodou světelné mikroskopie SOP-M-81 Material roslinny, drewno, material siewny, podloza, gleba, owady, osady, nicienie Wykrywanie i identyfikacja nicieni fitofagicznych, mykofagicznych i wolno zyjacych metoda mikroskopii swietlnej Rostlinny material, drevo, osivo, substraty, puda, hmyz, kaly, hlistice Detekce a identifikace fytofagnich, mykofagnich a volne zijicich hlistic metodou svetelne mikroskopie SOP-M-81","search_en":"Plant material, wood, seed, substrates, soil, insects, sludge, nematodes Detection and identification of phytophagous, mycophagous and free-living nematodes by light microscopy method SOP-M-81","search_zh":"植物材料、木材、种子、基质、土壤、昆虫、污泥、线虫 光学显微镜法检测和鉴定植食性、食菌性和自由生活线虫 SOP-M-81","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":265,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2084dfd57065325f557e71cb","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"11","test_object":"Podłoża, gleba, wody z płukania, osady, nicienie","test_object_en":"Substrates, soil, rinse water, sludge, nematodes","test_object_zh":"基质、土壤、冲洗水、污泥、线虫","test_object_cs":"Substráty, půda, oplachové vody, kaly, hlístice","methodology":"Wykrywanie cyst i identyfikacja mątwika ziemniaczanego (Globodera rostochiensis) i mątwika agresywnego (Globodera pallida) metodą mikroskopii świetlnej","methodology_en":"Detection of cysts and identification of potato cyst nematode (Globodera rostochiensis) and white potato cyst nematode (Globodera pallida) by light microscopy method","methodology_zh":"光学显微镜法检测孢囊并鉴定马铃薯金线虫（Globodera rostochiensis）和马铃薯白线虫（Globodera pallida）","methodology_cs":"Detekce cyst a identifikace háďátka bramborového (Globodera rostochiensis) a háďátka nažloutlého (Globodera pallida) metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie cyst i identyfikacja mątwika ziemniaczanego (Globodera rostochiensis) i mątwika agresywnego (Globodera pallida) metodą mikroskopii świetlnej","reference":"SOP-M-82","norm_bases":["SOP-M-82"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Dział Diagnostyki Organizmów Szkodliwych dla Roślin Havlíčkův Brod","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Department of Plant Pest Diagnostics Havlíčkův Brod","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，哈夫利奇库夫布罗德植物有害生物诊断科","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Oddělení diagnostiky škodlivých organismů rostlin Havlíčkův Brod","lab_address":"Konečná 1930, 580 01 Havlíčkův Brod","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: Rozporządzenie wykonawcze Komisji (UE) 2022/1192 z dnia 11 lipca 2022 r. ustanawiające środki w celu zwalczania i zapobiegania rozprzestrzenianiu się Globodera pallida (Stone) Behrens i Globodera rostochiensis (Wollenweber) Behrens. Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp., EPPO PM 7/40 Globodera rostochiensis and G. pallida.","note_en":"Source literature: Commission Implementing Regulation (EU) 2022/1192 of 11 July 2022 establishing measures to eradicate and prevent the spread of Globodera pallida (Stone) Behrens and Globodera rostochiensis (Wollenweber) Behrens. Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp., EPPO PM 7/40 Globodera rostochiensis and G. pallida.","note_zh":"参考文献：2022年7月11日委员会实施条例（EU）2022/1192，规定根除和防止Globodera pallida (Stone) Behrens和Globodera rostochiensis (Wollenweber) Behrens传播的措施。Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp., EPPO PM 7/40 Globodera rostochiensis and G. pallida.","note_cs":"Zdrojová literatura: PROVÁDĚCÍ NAŘÍZENÍ KOMISE (EU) 2022/1192 ze dne 11.července 2022, kterým se stanoví opatření k eradikaci a prevenci šíření organismů Globodera pallida (Stone) Behrens a Globodera rostochiensis (Wollenweber) Behrens. Van Benzooien, J., Methods and techniques for nematology. Wageningen, 2006, 112 pp., EPPO PM 7/40 Globodera rostochiensis and G. pallida.","search_text":"Podłoża, gleba, wody z płukania, osady, nicienie Wykrywanie cyst i identyfikacja mątwika ziemniaczanego (Globodera rostochiensis) i mątwika agresywnego (Globodera pallida) metodą mikroskopii świetlnej Substráty, půda, oplachové vody, kaly, hlístice Detekce cyst a identifikace háďátka bramborového (Globodera rostochiensis) a háďátka nažloutlého (Globodera pallida) metodou světelné mikroskopie SOP-M-82 Podloza, gleba, wody z plukania, osady, nicienie Wykrywanie cyst i identyfikacja matwika ziemniaczanego (Globodera rostochiensis) i matwika agresywnego (Globodera pallida) metoda mikroskopii swietlnej Substraty, puda, oplachove vody, kaly, hlistice Detekce cyst a identifikace hadatka bramboroveho (Globodera rostochiensis) a hadatka nazloutleho (Globodera pallida) metodou svetelne mikroskopie SOP-M-82","search_en":"Substrates, soil, rinse water, sludge, nematodes Detection of cysts and identification of potato cyst nematode (Globodera rostochiensis) and white potato cyst nematode (Globodera pallida) by light microscopy method SOP-M-82","search_zh":"基质、土壤、冲洗水、污泥、线虫 光学显微镜法检测孢囊并鉴定马铃薯金线虫（Globodera rostochiensis）和马铃薯白线虫（Globodera pallida） SOP-M-82","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":266,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0b09ed3e5f476aee85ca91b0","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"1","test_object":"Materiał roślinny, materiał siewny","test_object_en":"Plant material, seed","test_object_zh":"植物材料、种子","test_object_cs":"Rostlinný materiál, osivo","methodology":"Wykrywanie i identyfikacja wybranych gatunków z rodzaju Tilletia metodą mikroskopii świetlnej","methodology_en":"Detection and identification of selected species of the genus Tilletia by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定腥黑粉菌属（Tilletia）选定种类","methodology_cs":"Detekce a identifikace vybraných druhů rodu Tilletia metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja wybranych gatunków z rodzaju Tilletia metodą mikroskopii świetlnej","reference":"SOP-M-44","norm_bases":["SOP-M-44"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Laboratorium Diagnostyki Organizmów Szkodliwych dla Roślin Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Laboratory of Plant Pest Diagnostics Opava","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥帕瓦植物有害生物诊断实验室","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Laboratoř diagnostiky škodlivých organismů rostlin Opava","lab_address":"Jaselská 552/16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Wykaz identyfikowanych gatunków z rodzaju Tilletia: Tilletia controversa, Tilletia tritici, Tilletia indica, Tilletia foetida Literatura źródłowa: Kochanová, M., Prokinová, E., Metody diagnostiky Tilletia spp. v teorii a praxi, 2004, ČFS. 68 s. Właściwe standardy diagnostyczne EPPO: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_en":"List of identified species of the genus Tilletia: Tilletia controversa, Tilletia tritici, Tilletia indica, Tilletia foetida Source literature: Kochanová, M., Prokinová, E., Metody diagnostiky Tilletia spp. v teorii a praxi, 2004, ČFS. 68 p. Relevant EPPO diagnostic standards: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_zh":"鉴定的腥黑粉菌属（Tilletia）种类清单：Tilletia controversa, Tilletia tritici, Tilletia indica, Tilletia foetida参考文献：Kochanová, M., Prokinová, E., Metody diagnostiky Tilletia spp. v teorii a praxi, 2004, ČFS. 68页。相关EPPO诊断标准：https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","note_cs":"Seznam identifikovaných druhů z rodu Tilletia: Tilletia controversa, Tilletia tritici, Tilletia indica, Tilletia foetida Zdrojová literatura: Kochanová, M., Prokinová, E., Metody diagnostiky Tilletia spp. v teorii a praxi, 2004, ČFS. 68 p. Příslušné EPPO diagnostické standardy: https://www.eppo.int/RESOURCES/eppo_standards/pm7_diagnostics","search_text":"Materiał roślinny, materiał siewny Wykrywanie i identyfikacja wybranych gatunków z rodzaju Tilletia metodą mikroskopii świetlnej Rostlinný materiál, osivo Detekce a identifikace vybraných druhů rodu Tilletia metodou světelné mikroskopie SOP-M-44 Material roslinny, material siewny Wykrywanie i identyfikacja wybranych gatunkow z rodzaju Tilletia metoda mikroskopii swietlnej Rostlinny material, osivo Detekce a identifikace vybranych druhu rodu Tilletia metodou svetelne mikroskopie SOP-M-44","search_en":"Plant material, seed Detection and identification of selected species of the genus Tilletia by light microscopy method SOP-M-44","search_zh":"植物材料、种子 光学显微镜法检测和鉴定腥黑粉菌属（Tilletia）选定种类 SOP-M-44","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":267,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1710944236e4fc58264c0f70","lab_id":"69ad52a4de79e566650fd23e","country":"CZ","accr_number":"1071","accr_body":"ČIA","row_label":"2","test_object":"Materiał roślinny, owady, roztocze","test_object_en":"Plant material, insects, mites","test_object_zh":"植物材料、昆虫、螨类","test_object_cs":"Rostlinný materiál, hmyz, roztoči","methodology":"Wykrywanie i identyfikacja owadów fitofagicznych, saprofagicznych i drapieżnych oraz roztoczy metodą mikroskopii świetlnej","methodology_en":"Detection and identification of phytophagous, saprophagous and predatory insects and mites by light microscopy method","methodology_zh":"光学显微镜法检测和鉴定植食性、腐食性和捕食性昆虫及螨类","methodology_cs":"Detekce a identifikace fytofágního, saprofágního a dravého hmyzu a roztočů metodou světelné mikroskopie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie i identyfikacja owadów fitofagicznych, saprofagicznych i drapieżnych oraz roztoczy metodą mikroskopii świetlnej","reference":"SOP-M-61","norm_bases":["SOP-M-61"],"lab_section":"ÚKZÚZ, NRL, Wydział Diagnostyki Organizmów Szkodliwych dla Roślin, Laboratorium Diagnostyki Organizmów Szkodliwych dla Roślin Opawa","lab_section_en":"ÚKZÚZ, NRL, Division of Plant Pest Diagnostics, Laboratory of Plant Pest Diagnostics Opava","lab_section_zh":"ÚKZÚZ, NRL，植物有害生物诊断处，奥帕瓦植物有害生物诊断实验室","lab_section_cs":"ÚKZÚZ, NRL, Odbor diagnostiky škodlivých organismů rostlin, Laboratoř diagnostiky škodlivých organismů rostlin Opava","lab_address":"Jaselská 552/16, 746 01 Opava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":"Literatura źródłowa: HEIE O. E. 1980, 19802, 1986, 1992, 1994, 1995: The Aphidoidea (Hemiptera) of Fennoscandia and Denmark, cz. I., II., III., IV., V., VI. E. J. Brill, 236, 176, 313, 189, 242, 222 s. MACEK J. a kol. 2007: Motýli a housenky střední Evropy. Noční motýli I. Academia, 371 s. MACEK J. a kol. 2008: Motýli a housenky střední Evropy. Noční motýli II. – můrovití. Academia, 490 s. YEN A., BURCKHARDT D. 2017: Diagnostic Protocol for the detection of the Tomato Potato Psyllid, Bactericera cockerelli (Šulc). SPHDS, NDP 20: 1-34.","note_en":"Source literature: HEIE O. E. 1980, 19802, 1986, 1992, 1994, 1995: The Aphidoidea (Hemiptera) of Fennoscandia and Denmark, Part I., II., III., IV., V., VI. E. J. Brill, 236, 176, 313, 189, 242, 222 p. MACEK J. a kol. 2007: Motýli a housenky střední Evropy. Noční motýli I. Academia, 371 s. MACEK J. a kol. 2008: Motýli a housenky střední Evropy. Noční motýli II. – můrovití. Academia, 490 s. YEN A., BURCKHARDT D. 2017: Diagnostic Protocol for the detection of the Tomato Potato Psyllid, Bactericera cockerelli (Šulc). SPHDS, NDP 20: 1-34.","note_zh":"参考文献：HEIE O. E. 1980, 19802, 1986, 1992, 1994, 1995: The Aphidoidea (Hemiptera) of Fennoscandia and Denmark, 第I、II、III、IV、V、VI卷. E. J. Brill, 236, 176, 313, 189, 242, 222页。MACEK J. a kol. 2007: Motýli a housenky střední Evropy. Noční motýli I. Academia, 371 s.MACEK J. a kol. 2008: Motýli a housenky střední Evropy. Noční motýli II. – můrovití. Academia, 490 s.YEN A., BURCKHARDT D. 2017: Diagnostic Protocol for the detection of the Tomato Potato Psyllid, Bactericera cockerelli (Šulc). SPHDS, NDP 20: 1-34.","note_cs":"Zdrojová literatura: HEIE O. E. 1980, 19802, 1986, 1992, 1994, 1995: The Aphidoidea (Hemiptera) of Fennoscandia and Denmark, Díl. I., II., III., IV., V., VI. E. J. Brill, 236, 176, 313, 189, 242, 222 s. MACEK J. a kol. 2007: Motýli a housenky střední Evropy. Noční motýli I. Academia, 371 s. MACEK J. a kol. 2008: Motýli a housenky střední Evropy. Noční motýli II. – můrovití. Academia, 490 s. YEN A., BURCKHARDT D. 2017: Diagnostic Protocol for the detection of the Tomato Potato Psyllid, Bactericera cockerelli (Šulc). SPHDS, NDP 20: 1-34.","search_text":"Materiał roślinny, owady, roztocze Wykrywanie i identyfikacja owadów fitofagicznych, saprofagicznych i drapieżnych oraz roztoczy metodą mikroskopii świetlnej Rostlinný materiál, hmyz, roztoči Detekce a identifikace fytofágního, saprofágního a dravého hmyzu a roztočů metodou světelné mikroskopie SOP-M-61 Material roslinny, owady, roztocze Wykrywanie i identyfikacja owadow fitofagicznych, saprofagicznych i drapieznych oraz roztoczy metoda mikroskopii swietlnej Rostlinny material, hmyz, roztoci Detekce a identifikace fytofagniho, saprofagniho a draveho hmyzu a roztocu metodou svetelne mikroskopie SOP-M-61","search_en":"Plant material, insects, mites Detection and identification of phytophagous, saprophagous and predatory insects and mites by light microscopy method SOP-M-61","search_zh":"植物材料、昆虫、螨类 光学显微镜法检测和鉴定植食性、腐食性和捕食性昆虫及螨类 SOP-M-61","categories":["microbiology","other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":268,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}