{"lab":{"_id":"69ad52a4de79e566650fd23a","accr_number":"1064","country":"CZ","accr_body":"ČIA","address":"Kozí 748/4, 110 00 Praha 1","categories":["materials"],"city":"Praha 1","imported_at":"2026-03-08T10:42:44.590Z","methods_count":4,"name":"Puncovní úřad","parse_status":"parsed","parse_version":5,"pdf_files":["1064_74_2023_CS.pdf","1064_74_2023_EN.pdf"],"scope_summary":"Oznaczanie zawartości metali szlachetnych w stopach i roztworach.","search_text":"puncovní úřad kozí 748/4, 110 00 praha 1 1064","status":"active","updated_at":"2026-03-08T14:52:05.321Z","valid_from":"","valid_until":"20-05-2027","website":"www.puncovniurad.cz","location":{"type":"Point","coordinates":[14.4378,50.0755]},"map_coord":[50.090098,14.422803],"map_geo":"nominatim-street","certificate_date":"16.02.2023","certificate_no":"74/2023","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Oznaczanie zawartości metali szlachetnych w stopach i roztworach.","en":"Determination of precious metal content in alloys and solutions.","zh":"合金和溶液中贵金属含量的测定。","cs":"Stanovení obsahu drahých kovů ve slitinách a roztocích."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Dział Laboratoriów Badawczych Praga i akredytowane laboratorium badawcze","lab_division_cs":"Oddělení zkušebních laboratoří Praha a akreditovaná zkušební laboratoř","lab_division_en":"Testing Laboratories Department Prague and accredited testing laboratory","lab_division_zh":"布拉格检测实验室部及认可检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"6c1996a2ae76e4050199cb96d3b98c92eea1333dc08263ecfd81a5036de050aa","source_pdf_url":"https://www.cai.cz/OA/pdf/P74_2023_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"e3cac3157b33e8e558ccd8f6","lab_id":"69ad52a4de79e566650fd23a","country":"CZ","accr_number":"1064","accr_body":"ČIA","row_label":"1","test_object":"Stopy o zawartości złota 250 - 999 ‰ i zawartości niklu do 20 ‰","test_object_en":"Alloys with gold content 250 - 999 ‰ and nickel content up to 20 ‰","test_object_zh":"含金量250 - 999 ‰、含镍量不超过20 ‰的合金","test_object_cs":"Slitiny s obsahem zlata 250 - 999 ‰ a s obsahem niklu do 20 ‰","methodology":"Oznaczanie złota","methodology_en":"Determination of gold","methodology_zh":"金的测定","methodology_cs":"Stanovení zlata","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda kupelacyjna","technique_en":"Cupellation method","technique_zh":"灰吹法","technique_cs":"metodou kupelační","techniques":["Metoda kupelacyjna"],"techniques_en":["Cupellation method"],"techniques_zh":["灰吹法"],"techniques_cs":["metodou kupelační"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie złota\nMetoda kupelacyjna","reference":"ZAM 1.1 (ČSN EN ISO 11426:2017, kapitola 7.2)","norm_bases":["ZAM 1.1","ČSN EN ISO 11426:2017, kapitola 7.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stopy o zawartości złota 250 - 999 ‰ i zawartości niklu do 20 ‰ Oznaczanie złota Metoda kupelacyjna Slitiny s obsahem zlata 250 - 999 ‰ a s obsahem niklu do 20 ‰ Stanovení zlata metodou kupelační ZAM 1.1 (ČSN EN ISO 11426:2017, kapitola 7.2) Stopy o zawartosci zlota 250 - 999 ‰ i zawartosci niklu do 20 ‰ Oznaczanie zlota Metoda kupelacyjna Slitiny s obsahem zlata 250 - 999 ‰ a s obsahem niklu do 20 ‰ Stanoveni zlata metodou kupelacni ZAM 1.1 (CSN EN ISO 11426:2017, kapitola 7.2)","search_en":"Alloys with gold content 250 - 999 ‰ and nickel content up to 20 ‰ Determination of gold Cupellation method ZAM 1.1 (ČSN EN ISO 11426:2017, kapitola 7.2)","search_zh":"含金量250 - 999 ‰、含镍量不超过20 ‰的合金 金的测定 灰吹法 ZAM 1.1 (ČSN EN ISO 11426:2017, kapitola 7.2)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"925335516916d1503b58d439","lab_id":"69ad52a4de79e566650fd23a","country":"CZ","accr_number":"1064","accr_body":"ČIA","row_label":"2","test_object":"Stopy o zawartości złota 250 - 999 ‰ i zawartości niklu od 20 ‰ do 130 ‰","test_object_en":"Alloys with gold content 250 - 999 ‰ and nickel content from 20 ‰ to 130 ‰","test_object_zh":"含金量250 - 999 ‰、含镍量20 ‰至130 ‰的合金","test_object_cs":"Slitiny s obsahem zlata 250 - 999 ‰ a s obsahem niklu od 20 ‰ do 130 ‰","methodology":"Oznaczanie złota w stopie białego złota o zawartości niklu do 130 ‰","methodology_en":"Determination of gold in white gold alloy with nickel content up to 130 ‰","methodology_zh":"含镍量不超过130 ‰的白金合金中金的测定","methodology_cs":"Stanovení zlata v bílozlaté slitině s obsahem niklu do 130 ‰","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda kupelacyjna","technique_en":"Cupellation method","technique_zh":"灰吹法","technique_cs":"metodou kupelační","techniques":["Metoda kupelacyjna"],"techniques_en":["Cupellation method"],"techniques_zh":["灰吹法"],"techniques_cs":["metodou kupelační"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie złota w stopie białego złota o zawartości niklu do 130 ‰\nMetoda kupelacyjna","reference":"ZAM 1.2 (ČSN EN ISO 11426:2017, kapitola 7.3)","norm_bases":["ZAM 1.2","ČSN EN ISO 11426:2017, kapitola 7.3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stopy o zawartości złota 250 - 999 ‰ i zawartości niklu od 20 ‰ do 130 ‰ Oznaczanie złota w stopie białego złota o zawartości niklu do 130 ‰ Metoda kupelacyjna Slitiny s obsahem zlata 250 - 999 ‰ a s obsahem niklu od 20 ‰ do 130 ‰ Stanovení zlata v bílozlaté slitině s obsahem niklu do 130 ‰ metodou kupelační ZAM 1.2 (ČSN EN ISO 11426:2017, kapitola 7.3) Stopy o zawartosci zlota 250 - 999 ‰ i zawartosci niklu od 20 ‰ do 130 ‰ Oznaczanie zlota w stopie bialego zlota o zawartosci niklu do 130 ‰ Metoda kupelacyjna Slitiny s obsahem zlata 250 - 999 ‰ a s obsahem niklu od 20 ‰ do 130 ‰ Stanoveni zlata v bilozlate slitine s obsahem niklu do 130 ‰ metodou kupelacni ZAM 1.2 (CSN EN ISO 11426:2017, kapitola 7.3)","search_en":"Alloys with gold content 250 - 999 ‰ and nickel content from 20 ‰ to 130 ‰ Determination of gold in white gold alloy with nickel content up to 130 ‰ Cupellation method ZAM 1.2 (ČSN EN ISO 11426:2017, kapitola 7.3)","search_zh":"含金量250 - 999 ‰、含镍量20 ‰至130 ‰的合金 含镍量不超过130 ‰的白金合金中金的测定 灰吹法 ZAM 1.2 (ČSN EN ISO 11426:2017, kapitola 7.3)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e84b1830f5f1c590675ccb5b","lab_id":"69ad52a4de79e566650fd23a","country":"CZ","accr_number":"1064","accr_body":"ČIA","row_label":"3","test_object":"Stopy srebra rozpuszczalne w kwasie azotowym","test_object_en":"Silver alloys soluble in nitric acid","test_object_zh":"可溶于硝酸的银合金","test_object_cs":"Slitiny stříbra rozpustné v kyselině dusičné","methodology":"Oznaczanie srebra","methodology_en":"Determination of silver","methodology_zh":"银的测定","methodology_cs":"Stanovení stříbra","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Miareczkowanie potencjometryczne z NaCl","technique_en":"Potentiometric titration with NaCl","technique_zh":"NaCl电位滴定法","technique_cs":"potenciometrickou titrací s NaCl","techniques":["Miareczkowanie potencjometryczne z NaCl"],"techniques_en":["Potentiometric titration with NaCl"],"techniques_zh":["NaCl电位滴定法"],"techniques_cs":["potenciometrickou titrací s NaCl"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie srebra\nMiareczkowanie potencjometryczne z NaCl","reference":"ZAM 2.1 (ISO 13756)","norm_bases":["ZAM 2.1","ISO 13756"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stopy srebra rozpuszczalne w kwasie azotowym Oznaczanie srebra Miareczkowanie potencjometryczne z NaCl Slitiny stříbra rozpustné v kyselině dusičné Stanovení stříbra potenciometrickou titrací s NaCl ZAM 2.1 (ISO 13756) Stopy srebra rozpuszczalne w kwasie azotowym Oznaczanie srebra Miareczkowanie potencjometryczne z NaCl Slitiny stribra rozpustne v kyseline dusicne Stanoveni stribra potenciometrickou titraci s NaCl ZAM 2.1 (ISO 13756)","search_en":"Silver alloys soluble in nitric acid Determination of silver Potentiometric titration with NaCl ZAM 2.1 (ISO 13756)","search_zh":"可溶于硝酸的银合金 银的测定 NaCl电位滴定法 ZAM 2.1 (ISO 13756)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"53d0ee0efb2c87b0b907b7de","lab_id":"69ad52a4de79e566650fd23a","country":"CZ","accr_number":"1064","accr_body":"ČIA","row_label":"4","test_object":"Stopy i roztwory zawierające Au, Pt, Pd i Rh","test_object_en":"Alloys and solutions containing Au, Pt, Pd and Rh","test_object_zh":"含Au、Pt、Pd和Rh的合金及溶液","test_object_cs":"Slitiny a roztoky s obsahem Au, Pt, Pd a Rh","methodology":"Oznaczanie złota, platyny, palladu i rodu","methodology_en":"Determination of gold, platinum, palladium and rhodium","methodology_zh":"金、铂、钯和铑的测定","methodology_cs":"Stanovení zlata, platiny, palladia a rhodia","parameters":[{"name":"Złoto","range":""},{"name":"Platyna","range":""},{"name":"Pallad","range":""},{"name":"Rod","range":""}],"parameters_en":[{"name":"Gold","range":""},{"name":"Platinum","range":""},{"name":"Palladium","range":""},{"name":"Rhodium","range":""}],"parameters_zh":[{"name":"金","range":""},{"name":"铂","range":""},{"name":"钯","range":""},{"name":"铑","range":""}],"parameters_cs":[{"name":"zlata","range":""},{"name":"platiny","range":""},{"name":"palladia","range":""},{"name":"rhodia","range":""}],"technique":"Metoda ICP-OES","technique_en":"ICP-OES method","technique_zh":"ICP-OES法","technique_cs":"metodou ICP-OES","techniques":["Metoda ICP-OES"],"techniques_en":["ICP-OES method"],"techniques_zh":["ICP-OES法"],"techniques_cs":["metodou ICP-OES"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie złota, platyny, palladu i rodu\nZakres:\nZłoto\nPlatyna\nPallad\nRod\nMetoda ICP-OES","reference":"ZAM 5.9 (ČSN EN ISO 11494; ČSN EN ISO 11495)","norm_bases":["ZAM 5.9","ČSN EN ISO 11494","ČSN EN ISO 11495"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Stopy i roztwory zawierające Au, Pt, Pd i Rh Oznaczanie złota, platyny, palladu i rodu Metoda ICP-OES Złoto  Platyna  Pallad  Rod  Slitiny a roztoky s obsahem Au, Pt, Pd a Rh Stanovení zlata, platiny, palladia a rhodia metodou ICP-OES zlata  platiny  palladia  rhodia  ZAM 5.9 (ČSN EN ISO 11494; ČSN EN ISO 11495) Stopy i roztwory zawierajace Au, Pt, Pd i Rh Oznaczanie zlota, platyny, palladu i rodu Metoda ICP-OES Zloto  Platyna  Pallad  Rod  Slitiny a roztoky s obsahem Au, Pt, Pd a Rh Stanoveni zlata, platiny, palladia a rhodia metodou ICP-OES zlata  platiny  palladia  rhodia  ZAM 5.9 (CSN EN ISO 11494; CSN EN ISO 11495)","search_en":"Alloys and solutions containing Au, Pt, Pd and Rh Determination of gold, platinum, palladium and rhodium ICP-OES method Gold  Platinum  Palladium  Rhodium  ZAM 5.9 (ČSN EN ISO 11494; ČSN EN ISO 11495)","search_zh":"含Au、Pt、Pd和Rh的合金及溶液 金、铂、钯和铑的测定 ICP-OES法 金  铂  钯  铑  ZAM 5.9 (ČSN EN ISO 11494; ČSN EN ISO 11495)","categories":["materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}